UK Biobank
83 papers · 264 extracted observations · phenotype prediction · Markdown · CSV · JSON API
Also indexed as: uk-biobank
Tasks on UK BiobankAll tasks (83)Phenotype Prediction (7)Genome Wide Association Study (4)Image Generation (4)Bmi Prediction (3)Disease Classification (3)Brain Tissue Segmentation (2)Cardiovascular Risk Prediction (2)Disease Detection (2)
TaskPhenotype Prediction (34)Genome Wide Association Study (10)Image Generation (7)Disease Classification (7)Risk Prediction (7)Time to Event Prediction (6)Dementia Risk Prediction (6)
Metricauroc (27)auc (24)mae (22)accuracy (16)concordance index c index (6)average relative efficiency re (6)error rate (6)
Regimefine-tuned (10)5-fold-cross-validation (8)age-conditioned (6)gwas (6)transfer-learning (5)linear-probe (4)
Showing 27 of 27 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | PiLA (proposed physiology-guided self-supervised framework) proposed non-standard slice | AUROC | 0.7645 | Aortic Stenosis Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL109: PiLA (Ours) │ 0.7645 │ 0.7755 │ 0.7072 |
| 2026 | PiLA (proposed physiology-guided self-supervised framework) proposed non-standard slice | AUROC | 0.7756 | Aortic Regurgitation Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL122: PiLA (Ours) │ 0.7756 │ 0.7857 │ 0.7490 |
| 2026 | ResNet1D (Baseline) baseline | AUROC | 0.6985 | Aortic Stenosis Screening · split: test · supervised · input=single-beat PPG · training-data=limited labeled data · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL100: ResNet1D (Baseline) │ 0.6985 │ 0.6531 │ 0.6613 |
| 2026 | ResNet1D (Baseline) baseline | AUROC | 0.7013 | Aortic Regurgitation Screening · split: test · supervised · input=single-beat PPG · training-data=limited labeled data · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL113: ResNet1D (Baseline) │ 0.7013 │ 0.7143 │ 0.6786 |
| 2026 | BOADICEA baseline | AUROC | 0.66 | Phenotype Prediction | ECG2Gene: Deep Learning-Based Germline Tumor Susceptibility Gene Risk Assessment Using ElectrocardiogramsSource quoteL277: 0.66 ± 0.005 |
| 2025 | LoRA fine-tuned Mistral-7B-Instruct proposed | AUROC | 0.738 | Clinical Risk Prediction · split: test · fine-tuned · params=7B · backbone=Mistral-7B-Instruct · fine-tuning=LoRA · prediction-horizon=10-year | From Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMsSource quoteL78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738. |
| 2025 | LLM fine-tuned on structured data (Mistral-7B-Instruct with LoRA) proposed | AUROC | 0.685 | Clinical Risk Prediction · 0-shot · params=7B · backbone=Mistral-7B-Instruct · fine-tuning=LoRA · domain-shift=structured-to-notes · evaluation-input=synthetic clinical notes | From Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMsSource quoteL98: 0.685) and improves further with minimal adaptation (0.697 |
| 2025 | RETFound-DINOv2 proposed | Average AUROC | 0.599 | Systemic Disease Prediction · fine-tuned · backbone=DINOv2 · evaluation=external · training_dataset=AlzEye | Generalist versus Specialist Vision Foundation Models for Ocular Disease and OculomicsSource quoteL125: Biobank, which differs in imaging devices and participant demographics. RETFound-DINOv2 showed the strongest external performance, with the highest average AUROC (0.599), compared with |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.7501 | Disease Detection · split: test · subset=selected cohort | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL137: We choose area under the receiver operating characteristic curve (AUROC) as the indicator to evaluate model performance. For our task, AUROC is suitable for evaluating the performance of the model in a dataset with an imbalance of positive and negative samples. As shown in the Table \ref{tab:Demographic}, the number of healthy people in the dataset is much higher than that of patients with RHF, which is also in line with the actual clinical situation. Our model finally achieved AUROC=0.7501 on the test set, which shows that the model has good performance in predicting patients with RHF. |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.8194 | Disease Detection · split: test · subset=CKD | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed. |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.8413 | Disease Detection · split: test · subset=VHD | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed. |
| 2025 | Gradient-boosted trees baseline | AUROC | 0.738 | Risk Prediction · split: test · input=structured-tabular · risk-setting=base-risk-factor · prediction-horizon=10-year | Adaptable Cardiovascular Disease Risk Prediction from Heterogeneous Data using Large Language ModelsSource quoteL97: Its performance matched the performance of gradient-boosted trees (AUROC: 0.738), which are specifically designed for and known to excel with this setting of structured tabular inputs. |
| 2025 | LGBM baseline | AUROC | 0.738 | Clinical Risk Prediction · split: test · model=LGBM · prediction-horizon=10-year | From Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMsSource quoteL78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738. |
| 2025 | DINOv3-ViT-large baseline | Average AUROC | 0.549 | Systemic Disease Prediction · fine-tuned · backbone=ViT-large · evaluation=external · training_dataset=AlzEye | Generalist versus Specialist Vision Foundation Models for Ocular Disease and OculomicsSource quoteL126: RETFound-MAE (0.571), DINOv2-ViT-giant (0.560), and DINOv3-ViT-large (0.549); AUPRC and F1 followed the same ranking (Supplementary Figure 10). For ocular disease detection, AUROC values were similar across models, whereas RETFound-DINOv2 achieved the highest F1 score (0.402), followed by DINOv3-ViT-large (0.381), RETFound-MAE (0.367), and DINOv2-ViT-giant (0.365) (Supplementary Figure 11). |
| 2024 | CLIP+ITM proposed | AUROC | 0.93% | Stroke Risk Prediction · backbone=CLIP · method=CLIP+ITM · comparison=best supervised multimodal method | A Self-Supervised Model for Multi-modal Stroke Risk PredictionSource quoteL177: The CLIP+ITM model surpasses the self-supervised tabular (image) data SCARF (SimCLR) model by 2.6% (2.6%) in ROC-AUC, and by 3.3% (5.6%) in balanced accuracy terms. Our framework also demonstrated an AUROC improvement of 0.93% and 7.6% balanced accuracy from the best multi-modal supervised method. Additionally, the proposed model produces well-aligned multi-modal representations in a common, data modality-independent space, which is unattainable with unimodal tabular or imaging data models. Thus, CLIP-ITM effectively leverages complementary and synergistic information from diverse data modalities. |
| 2024 | DeepSpiro proposed non-standard slice | AUROC | 0.8328 | Copd Detection · subset=all (complete dataset) | Deep learning for detecting and early predicting chronic obstructive pulmonary disease from spirogram time seriesSource quoteL61: DeepSpiro │ 0.8328 │ 0.3570 │ 0.3950 |
| 2024 | EyeFound proposed | AUROC | 0.634 | Stroke Prediction · imaging-modality=CFP | EyeFound: A Multimodal Generalist Foundation Model for Ophthalmic ImagingSource quoteL111: PD, and MI in the UK Biobank dataset using ocular images. Our model outperformed RETFound in predicting stroke, dementia, and PD using CFP, achieving AUROC scores of 0.634, 0.547, and 0.571, respectively (all P<0.05). The same trend is also observed in AUPR, with scores of 0.624, 0.583, and |
| 2024 | EyeFound proposed | AUROC | 0.547 | Dementia Prediction · imaging-modality=CFP | EyeFound: A Multimodal Generalist Foundation Model for Ophthalmic ImagingSource quoteL111: PD, and MI in the UK Biobank dataset using ocular images. Our model outperformed RETFound in predicting stroke, dementia, and PD using CFP, achieving AUROC scores of 0.634, 0.547, and 0.571, respectively (all P<0.05). The same trend is also observed in AUPR, with scores of 0.624, 0.583, and |
| 2024 | EyeFound proposed | AUROC | 0.571 | Parkinsons Disease Prediction · imaging-modality=CFP | EyeFound: A Multimodal Generalist Foundation Model for Ophthalmic ImagingSource quoteL111: PD, and MI in the UK Biobank dataset using ocular images. Our model outperformed RETFound in predicting stroke, dementia, and PD using CFP, achieving AUROC scores of 0.634, 0.547, and 0.571, respectively (all P<0.05). The same trend is also observed in AUPR, with scores of 0.624, 0.583, and |
| 2023 | HeLM (tabular + spirogram) proposed | AUROC | 0.75 | Asthma Prediction · modalities=tabular+spirogram | Multimodal LLMs for health grounded in individual-specific dataSource quoteL7: Using data from the UK Biobank, we show that HeLM can effectively use demographic and clinical features in addition to high-dimensional time-series data to estimate disease risk. For example, HeLM achieves an AUROC of 0.75 for asthma prediction when combining tabular and spirogram data modalities compared with 0.49 when only using tabular data. Overall, we find that HeLM outperforms or performs at parity with classical machine learning approaches across a selection of eight binary traits. Furthermore, we investigate the downstream uses of this model such as its generalizability to out-of-distribution traits and its ability to power conversations around individual health and wellness. |
| 2023 | Tabular-only input ablation | AUROC | 0.49 | Asthma Prediction · modalities=tabular-only | Multimodal LLMs for health grounded in individual-specific dataSource quoteL7: Using data from the UK Biobank, we show that HeLM can effectively use demographic and clinical features in addition to high-dimensional time-series data to estimate disease risk. For example, HeLM achieves an AUROC of 0.75 for asthma prediction when combining tabular and spirogram data modalities compared with 0.49 when only using tabular data. Overall, we find that HeLM outperforms or performs at parity with classical machine learning approaches across a selection of eight binary traits. Furthermore, we investigate the downstream uses of this model such as its generalizability to out-of-distribution traits and its ability to power conversations around individual health and wellness. |
| 2022 | POPDx proposed | AUROC | 0.71 | Phenotype Recognition · few-shot · sampling-ratio=positive:negative 1:10 · training-samples=0–10 per phenotype | POPDx: An Automated Framework for Patient Phenotyping across 392,246 Individuals in the UK Biobank StudySource quoteL155: Under the Receiver Operating Characteristic Curve) scores of 0.71 and 0.74 for phenotypes with |
| 2022 | POPDx proposed | AUROC | 0.74 | Phenotype Recognition · few-shot · sampling-ratio=positive:negative 1:10 · training-samples=10–100 per phenotype | POPDx: An Automated Framework for Patient Phenotyping across 392,246 Individuals in the UK Biobank StudySource quoteL155: Under the Receiver Operating Characteristic Curve) scores of 0.71 and 0.74 for phenotypes with |
| 2022 | POPDx proposed | AUROC | 0.68 | Phenotype Recognition · 0-shot · sampling-ratio=positive:negative 1:10 · training-samples=0 per phenotype | POPDx: An Automated Framework for Patient Phenotyping across 392,246 Individuals in the UK Biobank StudySource quoteL157: Curve) scores improve with training size. We also investigated performance for phenotypes with no patient sample in the training dataset. For these, POPDx achieves an AUROC score of 0.68 and an AUPRC score of 0.24, which are 74% and 218% higher than those of the logistic regression baseline. A sampling ratio of positive to negative patients of 1:10 is consistently used to report the |
| 2022 | POPDx proposed | AUROC (Mean) | 0.8141 | Phenotype Recognition · phenotypes=131 · sampling-ratio=positive:negative 1:10 · phenotype-category=circulatory system | POPDx: An Automated Framework for Patient Phenotyping across 392,246 Individuals in the UK Biobank StudySource quoteL175: 0.8141 0.0725 0.3695 0.1238 (GI) Diseases of the digestive system |
| 2021 | ContIG (PGS; H1) proposed | ROC-AUC | 72.72 | Cardiovascular Risk Prediction · split: test · fine-tuned | ContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with GeneticsSource quoteL209: ContIG (PGS) │ H1 │ 85.93 │ 93.31 │ 78.47 │ 3.176 │ 72.72 |
| 2021 | NNCLR baseline | ROC-AUC | 61.95 | Cardiovascular Risk Prediction · split: test · fine-tuned | ContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with GeneticsSource quoteL206: NNCLR~\cite{nnclr} │ 77.93 │ 91.89 │ 72.06 │ 3.426 │ 61.95 |