UK Biobank

83 papers · 264 extracted observations · phenotype prediction · Markdown · CSV · JSON API

Also indexed as: uk-biobank

Showing 12 of 12 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026PiLA (proposed physiology-guided self-supervised framework) proposed non-standard sliceAUROC0.7645Aortic Stenosis Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 pointsAortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning
Source quote
L109: PiLA (Ours) │ 0.7645 │ 0.7755 │ 0.7072
2026PiLA (proposed physiology-guided self-supervised framework) proposed non-standard sliceAUROC0.7756Aortic Regurgitation Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 pointsAortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning
Source quote
L122: PiLA (Ours) │ 0.7756 │ 0.7857 │ 0.7490
2026ResNet1D (Baseline) baselineAUROC0.6985Aortic Stenosis Screening · split: test · supervised · input=single-beat PPG · training-data=limited labeled data · waveform-length=100 pointsAortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning
Source quote
L100: ResNet1D (Baseline) │ 0.6985 │ 0.6531 │ 0.6613
2026ResNet1D (Baseline) baselineAUROC0.7013Aortic Regurgitation Screening · split: test · supervised · input=single-beat PPG · training-data=limited labeled data · waveform-length=100 pointsAortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning
Source quote
L113: ResNet1D (Baseline) │ 0.7013 │ 0.7143 │ 0.6786
2025LoRA fine-tuned Mistral-7B-Instruct proposedAUROC0.738Clinical Risk Prediction · split: test · fine-tuned · params=7B · backbone=Mistral-7B-Instruct · fine-tuning=LoRA · prediction-horizon=10-yearFrom Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMs
Source quote
L78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738.
2025SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard sliceAUROC0.7501Disease Detection · split: test · subset=selected cohortArtificial Intelligence-Enabled Spirometry for Early Detection of Right Heart Failure
Source quote
L137: We choose area under the receiver operating characteristic curve (AUROC) as the indicator to evaluate model performance. For our task, AUROC is suitable for evaluating the performance of the model in a dataset with an imbalance of positive and negative samples. As shown in the Table \ref{tab:Demographic}, the number of healthy people in the dataset is much higher than that of patients with RHF, which is also in line with the actual clinical situation. Our model finally achieved AUROC=0.7501 on the test set, which shows that the model has good performance in predicting patients with RHF.
2025SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard sliceAUROC0.8194Disease Detection · split: test · subset=CKDArtificial Intelligence-Enabled Spirometry for Early Detection of Right Heart Failure
Source quote
L142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed.
2025SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard sliceAUROC0.8413Disease Detection · split: test · subset=VHDArtificial Intelligence-Enabled Spirometry for Early Detection of Right Heart Failure
Source quote
L142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed.
2025Gradient-boosted trees baselineAUROC0.738Risk Prediction · split: test · input=structured-tabular · risk-setting=base-risk-factor · prediction-horizon=10-yearAdaptable Cardiovascular Disease Risk Prediction from Heterogeneous Data using Large Language Models
Source quote
L97: Its performance matched the performance of gradient-boosted trees (AUROC: 0.738), which are specifically designed for and known to excel with this setting of structured tabular inputs.
2025LGBM baselineAUROC0.738Clinical Risk Prediction · split: test · model=LGBM · prediction-horizon=10-yearFrom Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMs
Source quote
L78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738.
2021ContIG (PGS; H1) proposedROC-AUC72.72Cardiovascular Risk Prediction · split: test · fine-tunedContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with Genetics
Source quote
L209: ContIG (PGS) │ H1 │ 85.93 │ 93.31 │ 78.47 │ 3.176 │ 72.72
2021NNCLR baselineROC-AUC61.95Cardiovascular Risk Prediction · split: test · fine-tunedContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with Genetics
Source quote
L206: NNCLR~\cite{nnclr} │ 77.93 │ 91.89 │ 72.06 │ 3.426 │ 61.95