UK Biobank
83 papers · 264 extracted observations · phenotype prediction · Markdown · CSV · JSON API
Also indexed as: uk-biobank
Tasks on UK BiobankAll tasks (83)Phenotype Prediction (7)Genome Wide Association Study (4)Image Generation (4)Bmi Prediction (3)Disease Classification (3)Brain Tissue Segmentation (2)Cardiovascular Risk Prediction (2)Disease Detection (2)
TaskPhenotype Prediction (34)Genome Wide Association Study (10)Image Generation (7)Disease Classification (7)Risk Prediction (7)Time to Event Prediction (6)Dementia Risk Prediction (6)
Metricauroc (27)auc (24)mae (22)accuracy (16)concordance index c index (6)average relative efficiency re (6)error rate (6)
Regimefine-tuned (10)5-fold-cross-validation (8)age-conditioned (6)gwas (6)transfer-learning (5)linear-probe (4)
Showing 12 of 12 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | PiLA (proposed physiology-guided self-supervised framework) proposed non-standard slice | AUROC | 0.7645 | Aortic Stenosis Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL109: PiLA (Ours) │ 0.7645 │ 0.7755 │ 0.7072 |
| 2026 | PiLA (proposed physiology-guided self-supervised framework) proposed non-standard slice | AUROC | 0.7756 | Aortic Regurgitation Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL122: PiLA (Ours) │ 0.7756 │ 0.7857 │ 0.7490 |
| 2026 | ResNet1D (Baseline) baseline | AUROC | 0.6985 | Aortic Stenosis Screening · split: test · supervised · input=single-beat PPG · training-data=limited labeled data · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL100: ResNet1D (Baseline) │ 0.6985 │ 0.6531 │ 0.6613 |
| 2026 | ResNet1D (Baseline) baseline | AUROC | 0.7013 | Aortic Regurgitation Screening · split: test · supervised · input=single-beat PPG · training-data=limited labeled data · waveform-length=100 points | Aortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised LearningSource quoteL113: ResNet1D (Baseline) │ 0.7013 │ 0.7143 │ 0.6786 |
| 2025 | LoRA fine-tuned Mistral-7B-Instruct proposed | AUROC | 0.738 | Clinical Risk Prediction · split: test · fine-tuned · params=7B · backbone=Mistral-7B-Instruct · fine-tuning=LoRA · prediction-horizon=10-year | From Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMsSource quoteL78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738. |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.7501 | Disease Detection · split: test · subset=selected cohort | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL137: We choose area under the receiver operating characteristic curve (AUROC) as the indicator to evaluate model performance. For our task, AUROC is suitable for evaluating the performance of the model in a dataset with an imbalance of positive and negative samples. As shown in the Table \ref{tab:Demographic}, the number of healthy people in the dataset is much higher than that of patients with RHF, which is also in line with the actual clinical situation. Our model finally achieved AUROC=0.7501 on the test set, which shows that the model has good performance in predicting patients with RHF. |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.8194 | Disease Detection · split: test · subset=CKD | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed. |
| 2025 | SLSE (VAE-encoder spirogram embedding fused with demographic information; CatBoost classifier) proposed non-standard slice | AUROC | 0.8413 | Disease Detection · split: test · subset=VHD | Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart FailureSource quoteL142: Ultimately, we find that the model achieves better AUROC performance on VHD, CKD, CHD, diabetes, and smoking subsets than when tested on the entire test set (Figure \ref{fig:subgroup}a), particularly achieving an AUROC=0.8194 on the CKD subset, and an AUROC=0.8413 on the VHD subset. This demonstrates the potential of our model for predicting RHF in CKD and VHD patients. For a excellent AUROC performance on this two subsets, it is possibly because CKD and VHD will increase circulatory load, which significantly exacerbates the symptoms of RHF when combined with it. As for the differences in subgroup distribution, Figure \ref{fig:subgroup}c CKD group shows that the RHF prediction probability distribution for patients with CKD is significantly broader than that for those without CKD, and the median prediction probability is also larger; the same applies to VHD subgroup (Figure \ref{fig:subgroup}c VHD group). The p-values indicate that the model has strong classification ability for the CKD subgroup but weaker classification ability for the VHD subgroup, suggesting that further validation with more VHD patient samples may be needed. |
| 2025 | Gradient-boosted trees baseline | AUROC | 0.738 | Risk Prediction · split: test · input=structured-tabular · risk-setting=base-risk-factor · prediction-horizon=10-year | Adaptable Cardiovascular Disease Risk Prediction from Heterogeneous Data using Large Language ModelsSource quoteL97: Its performance matched the performance of gradient-boosted trees (AUROC: 0.738), which are specifically designed for and known to excel with this setting of structured tabular inputs. |
| 2025 | LGBM baseline | AUROC | 0.738 | Clinical Risk Prediction · split: test · model=LGBM · prediction-horizon=10-year | From Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMsSource quoteL78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738. |
| 2021 | ContIG (PGS; H1) proposed | ROC-AUC | 72.72 | Cardiovascular Risk Prediction · split: test · fine-tuned | ContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with GeneticsSource quoteL209: ContIG (PGS) │ H1 │ 85.93 │ 93.31 │ 78.47 │ 3.176 │ 72.72 |
| 2021 | NNCLR baseline | ROC-AUC | 61.95 | Cardiovascular Risk Prediction · split: test · fine-tuned | ContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with GeneticsSource quoteL206: NNCLR~\cite{nnclr} │ 77.93 │ 91.89 │ 72.06 │ 3.426 │ 61.95 |