UK Biobank

83 papers · 264 extracted observations · phenotype prediction · Markdown · CSV · JSON API

Also indexed as: uk-biobank

Showing 7 of 7 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026PiLA (proposed physiology-guided self-supervised framework) proposed non-standard sliceAUROC0.7645Aortic Stenosis Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 pointsAortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning
Source quote
L109: PiLA (Ours) │ 0.7645 │ 0.7755 │ 0.7072
2026PiLA (proposed physiology-guided self-supervised framework) proposed non-standard sliceAUROC0.7756Aortic Regurgitation Screening · split: test · fine-tuned · input=single-beat PPG · pretraining=over 170,000 unlabeled PPG samples · waveform-length=100 pointsAortic Valve Disease Screening from PPG via Physiology-Guided Self-Supervised Learning
Source quote
L122: PiLA (Ours) │ 0.7756 │ 0.7857 │ 0.7490
2025LoRA fine-tuned Mistral-7B-Instruct proposedAUROC0.738Clinical Risk Prediction · split: test · fine-tuned · params=7B · backbone=Mistral-7B-Instruct · fine-tuning=LoRA · prediction-horizon=10-yearFrom Structured Data to Clinical Notes: Robust Clinical Decision Support with Fine-Tuned LLMs
Source quote
L78: Figure 2 shows the performance using only the base risk factors as inputs. Both the LLM-based model and LGBM achieved state-of-the-art performance for CVD risk prediction, with an area under the receiver operating characteristic curve (AUROC) of 0.738.
2025RETFound-DINOv2 proposedAverage AUROC0.599Systemic Disease Prediction · fine-tuned · backbone=DINOv2 · evaluation=external · training_dataset=AlzEyeGeneralist versus Specialist Vision Foundation Models for Ocular Disease and Oculomics
Source quote
L125: Biobank, which differs in imaging devices and participant demographics. RETFound-DINOv2 showed the strongest external performance, with the highest average AUROC (0.599), compared with
2025DINOv3-ViT-large baselineAverage AUROC0.549Systemic Disease Prediction · fine-tuned · backbone=ViT-large · evaluation=external · training_dataset=AlzEyeGeneralist versus Specialist Vision Foundation Models for Ocular Disease and Oculomics
Source quote
L126: RETFound-MAE (0.571), DINOv2-ViT-giant (0.560), and DINOv3-ViT-large (0.549); AUPRC and F1 followed the same ranking (Supplementary Figure 10). For ocular disease detection, AUROC values were similar across models, whereas RETFound-DINOv2 achieved the highest F1 score (0.402), followed by DINOv3-ViT-large (0.381), RETFound-MAE (0.367), and DINOv2-ViT-giant (0.365) (Supplementary Figure 11).
2021ContIG (PGS; H1) proposedROC-AUC72.72Cardiovascular Risk Prediction · split: test · fine-tunedContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with Genetics
Source quote
L209: ContIG (PGS) │ H1 │ 85.93 │ 93.31 │ 78.47 │ 3.176 │ 72.72
2021NNCLR baselineROC-AUC61.95Cardiovascular Risk Prediction · split: test · fine-tunedContIG: Self-supervised Multimodal Contrastive Learning for Medical Imaging with Genetics
Source quote
L206: NNCLR~\cite{nnclr} │ 77.93 │ 91.89 │ 72.06 │ 3.426 │ 61.95