YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024CLIP+ITM proposedbalanced accuracy3.3%Stroke Risk Prediction · backbone=CLIP · method=CLIP+ITM · comparison=SCARFA Self-Supervised Model for Multi-modal Stroke Risk Prediction
Source quote
L177: The CLIP+ITM model surpasses the self-supervised tabular (image) data SCARF (SimCLR) model by 2.6% (2.6%) in ROC-AUC, and by 3.3% (5.6%) in balanced accuracy terms. Our framework also demonstrated an AUROC improvement of 0.93% and 7.6% balanced accuracy from the best multi-modal supervised method. Additionally, the proposed model produces well-aligned multi-modal representations in a common, data modality-independent space, which is unattainable with unimodal tabular or imaging data models. Thus, CLIP-ITM effectively leverages complementary and synergistic information from diverse data modalities.
2024CLIP+ITM proposedbalanced accuracy5.6%Stroke Risk Prediction · backbone=CLIP · method=CLIP+ITM · comparison=SimCLRA Self-Supervised Model for Multi-modal Stroke Risk Prediction
Source quote
L177: The CLIP+ITM model surpasses the self-supervised tabular (image) data SCARF (SimCLR) model by 2.6% (2.6%) in ROC-AUC, and by 3.3% (5.6%) in balanced accuracy terms. Our framework also demonstrated an AUROC improvement of 0.93% and 7.6% balanced accuracy from the best multi-modal supervised method. Additionally, the proposed model produces well-aligned multi-modal representations in a common, data modality-independent space, which is unattainable with unimodal tabular or imaging data models. Thus, CLIP-ITM effectively leverages complementary and synergistic information from diverse data modalities.
2024CLIP+ITM proposedbalanced accuracy7.6%Stroke Risk Prediction · backbone=CLIP · method=CLIP+ITM · comparison=best supervised multimodal methodA Self-Supervised Model for Multi-modal Stroke Risk Prediction
Source quote
L177: The CLIP+ITM model surpasses the self-supervised tabular (image) data SCARF (SimCLR) model by 2.6% (2.6%) in ROC-AUC, and by 3.3% (5.6%) in balanced accuracy terms. Our framework also demonstrated an AUROC improvement of 0.93% and 7.6% balanced accuracy from the best multi-modal supervised method. Additionally, the proposed model produces well-aligned multi-modal representations in a common, data modality-independent space, which is unattainable with unimodal tabular or imaging data models. Thus, CLIP-ITM effectively leverages complementary and synergistic information from diverse data modalities.
2024Proposed multi-modal self-supervised model proposedbalanced accuracy7.6%Myocardial Infarction Diagnosis · fine-tunedEnhancing Cardiovascular Disease Prediction through Multi-Modal Self-Supervised Learning
Source quote
L178: As a baseline, we train the NN \cite{erickson2020autogluon} in a supervised manner on tabular data, ECG signals, and a combination of them. We compared our method with simple NN supervised approaches due to the limited availability of annotated data, which restricted our ability to explore more advanced supervised methods. We extracted the features from ECG signal \cite{lubba2019catch22,ji2022time} for concatenating them with tabular features. As seen in table \ref{tab:self_supervised}, the performance of supervised learning on tabular data only and ECG signals only results in balanced accuracy of 54% and 66% respectively. Training the model on a combination of ECG signals and tabular information results in 65% balanced accuracy which is likely due to the overfitting on the small task-specific data using only 1524 samples with balanced diseased and healthy individuals. However, our approach with pre-training the model on multiple modalities including images and fine-tuning on labeled data outperforms the supervised method by 7.6% increase in balanced accuracy.
2020PIF-A proposed non-standard slicebalanced accuracy (Bal. acc.)88.41%Disease Classification · subset=small data set; 371 samplesHarnessing spatial homogeneity of neuroimaging data: patch individual filter layers for CNNs
Source quote
L132: UK Biobank │ PIF-A │ 93.75% (1.09) │ 48.9 │ 88.41% (3.52) │ 72.7
2020ICAM proposedAccuracy0.943Age Classification · split: test · classes=ages 45–60 vs 70–80ICAM: Interpretable Classification via Disentangled Representations and Feature Attribution Mapping
Source quote
L177: We achieved 0.943 accuracy on the test dataset with ICAM on age classification, but cannot compare to VA-GAN, as it cannot perform class prediction. We compare the feature attribution maps and translated images against VA-GAN (Fig.~\ref{fig:biobank_comparison}, and Fig.~\ref{fig:biobank_very_old_young}). While we do not have ground truth maps for a comparison in Biobank, it is commonly described within the neuroscience domain that hippocampal atrophy \cite{o2016cognitive}, decrease in cortical thickness, and the enlargement of the ventricles are often observed with ageing, and are indicative of neurodegeneration \cite{guo2017mri, pacheco2015greater}. We looked for this phenotypic variation in our qualitative analysis. For ICAM we plot variance, and mean FA maps (computed through multiple sampling of the attribute latent space in test time); for VA-GAN we show only FA as it can only generate a single deterministic output. We found that VA-GAN was able to detect some variation in the ventricles and cortex, but that ICAM was able to detect more variability in the ventricles (blue arrows), cortex (green arrows), and in the hippocampus (purple arrow). Interestingly, the variance map detects higher variability in the ventricles and the cortex, which may reflect heterogeneity in the ageing process. We also note that while ICAM is able to change the shape of different brain regions in translation (e.g. shrinking the ventricles, or enlarging the cortical folds), VA-GAN is only able to change the pixel intensities, and does not appear to change the shape. This is a significant advantage for ICAM compared to previous methods, as shape is an important phenotype in many other medical datasets \cite{garcia2018dynamic, kapellou2006abnormal}, and thus is likely to generalise well.
2019Reverse Classification Accuracy (RCA) proposedbinary classification accuracy0.988Segmentation Quality Control · split: val · segmenter=random-forest · sample-size=400 · segmentation=whole-heartAutomated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging Study
Source quote
L188: WH │ 0.988 │ 0.979 │ 0.000 │ \multirow{2}{*}{0.029} │ \multirow{2}{*}{4.445} │ \multirow{2}{*}{5.504} │ \multirow{2}{*}{15.11}
2019Reverse Classification Accuracy (RCA) proposed non-standard slicebinary classification accuracy0.954Segmentation Quality Control · trees=500 · depths=5, 40 · segmenter=random-forest · sample-size=4800 · segmentation=whole-heartAutomated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging Study
Source quote
L222: WH │ 0.954 │ 0.966 │ 0.148 │ \multirow{2}{*}{0.035} │ \multirow{2}{*}{1.156} │ \multirow{2}{*}{2.762} │ \multirow{2}{*}{12.52}
2019Reverse Classification Accuracy (RCA) proposed non-standard slicebinary classification accuracy0.978Segmentation Quality Control · trees=500 · depths=5, 40 · segmenter=random-forest · sample-size=4800 · segmentation=whole-heartAutomated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging Study
Source quote
L223: 0.978 │ 0.984 │ 0.027
2019Reverse Classification Accuracy (RCA) proposed non-standard slicebinary classification accuracy0.998Segmentation Quality Control · segmenter=cnn · sample-size=900 · segmentation=whole-heartAutomated Quality Control in Image Segmentation: Application to the UK Biobank Cardiac MR Imaging Study
Source quote
L244: WH │ 0.998 │ 1.000 │ 0.000 │ \multirow{2}{*}{0.089} │ \multirow{2}{*}{0.460} │ \multirow{2}{*}{0.509} │ \multirow{2}{*}{1.698}
2018Proposed CNN, Experiment 1 (manual-GT DSC supervision) proposedBinary classification accuracy0.965Segmentation Quality Prediction · modality=CMR · experiment=1 · segmentation=whole-heart · DSC-threshold=0.70 · quality-supervision=manual-GT DSCReal-Time Prediction of Segmentation Quality
Source quote
L83: \multicolumn{1}{c}{} │ \multicolumn{1}{|c}{TPR 0.975} │ \multicolumn{1}{c}{FPR 0.060} │ \multicolumn{1}{c|}{Acc. 0.965} │ \multicolumn{1}{c}{TPR 0.879} │ \multicolumn{1}{c}{FPR 0.000} │ \multicolumn{1}{c|}{Acc. 0.906}
2018Proposed CNN, Experiment 2 (reverse-testing/RCA-derived quality supervision) proposedBinary classification accuracy0.906Segmentation Quality Prediction · split: test · modality=CMR · experiment=2 · segmentation=whole-heart · quality-supervision=reverse-testing/RCA-derivedReal-Time Prediction of Segmentation Quality
Source quote
L83: \multicolumn{1}{c}{} │ \multicolumn{1}{|c}{TPR 0.975} │ \multicolumn{1}{c}{FPR 0.060} │ \multicolumn{1}{c|}{Acc. 0.965} │ \multicolumn{1}{c}{TPR 0.879} │ \multicolumn{1}{c}{FPR 0.000} │ \multicolumn{1}{c|}{Acc. 0.906}