UBFC · Heart Rate Estimation
15 papers · 29 extracted observations · heart rate estimation · Markdown · CSV · JSON API
Metricmae (19)rmse (4)bvp signal to noise ratio snr (2)pearson correlation (2)accuracy (1)throughput (1)
Splittest (5)
Showing 19 of 19 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | StreamPPG (frame-wise) proposed | Throughput | 290 fps | Heart Rate Estimation · processing=frame-wise | StreamPPG: Low-Latency rPPG Estimation via Consistent Privileged LearningSource quoteL394: StreamPPG │ F │ 2.92 │ 1.59 │ 290 │ 405.75 │ 0.27 |
| 2026 | StreamPPG (frame-wise) proposed | RMSE | 0.27 bpm | Heart Rate Estimation · processing=frame-wise | StreamPPG: Low-Latency rPPG Estimation via Consistent Privileged LearningSource quoteL394: StreamPPG │ F │ 2.92 │ 1.59 │ 290 │ 405.75 │ 0.27 |
| 2026 | StreamPPG proposed | RMSE | 0.22 bpm | Heart Rate Estimation · resolution=256×256 · hardware=Jetson AGX Orin | StreamPPG: Low-Latency rPPG Estimation via Consistent Privileged LearningSource quoteL412: StreamPPG │ 56 │ 0.31 │ 54 │ 0.27 │ 53 │ 0.27 │ 54 │ 0.22 |
| 2025 | CiCi proposed | MAE | 3.55 | Heart Rate Estimation · split: test · test-time-adaptation · training=HSRD-trained on other four datasets | Not Only Consistency: Enhance Test-Time Adaptation with Spatio-temporal Inconsistency for Remote Physiological MeasurementSource quoteL197: CiCi │ 3.55\(^*\) │ 6.27\(^*\) │ 0.89 │ 4.96\(^*\) │ 7.99\(^*\) │ 0.90\(^*\) │ 1.49\(^*\) │ 1.96\(^*\) │ 0.99 │ 6.87\(^*\) │ 10.59\(^*\) │ 0.64\(^*\) │ 8.58\(^*\) │ 11.03\(^*\) │ 0.54\(^*\) |
| 2024 | TSCAN-TN proposed | MAE | 0.519 | Heart Rate Estimation · training-dataset=MMPD | A Plug-and-Play Temporal Normalization Module for Robust Remote PhotoplethysmographySource quoteL293: The TN module can improve training performance on complex, high-noise real-world datasets. MMPD \cite{tang2023mmpd}, recognized as a challenging dataset for real-world validation, is difficult to train on due to significant video compression and motion noise. Most previous research either failed to train on the full MMPD dataset \cite{Liu2024SpikingPhysFormerCR} or opted to train on a subset\cite{Zhao_2024_CVPR}. In contrast, our TN module enables all methods to successfully train on the entire MMPD dataset in Table \ref{resultmmpd}, with performance gains ranging from 34.3% to 98.8%. Moreover, it helps achieve clinical-level accuracy (MAE below 2) in cross-dataset experiments: 1.114 with TN-Net on RLAP, 2.042 with PhysNet-TN on COHFACE, 0.622 with TN-Net on PURE, and 0.519 with TSCAN-TN on UBFC. |
| 2024 | PhysMLE-R proposed | HR MAE | 4.353 bpm | Heart Rate Estimation · split: test · cross-domain · protocol=MSSDG Protocol I | PhysMLE: Generalizable and Priors-Inclusive Multi-Task Remote Physiological MeasurementSource quoteL382: PhysMLE-R │ 0.056 │ 0.073 │ 0.248 │ 0.056 │ 0.073 │ 0.248 │ 0.223 │ 0.296 │ 0.345 │ 4.353 │ 5.081 │ 0.850 |
| 2024 | Bi-TTA proposed | M↓ (MAE) | 3.53 | Heart Rate Estimation | Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological MeasurementSource quoteL233: Ours │ \textbf{{7.09}} │ \textbf{{10.72}} │ \textbf{{0.63}} │ 9.1 │ 11.02 │ 0.54 │ \textbf{{5.02}} │ \textbf{{8.11}} │ \textbf{{0.890}} │ 3.53 │ 6.24 │ 0.891 │ \textbf{{1.49}} │ \textbf{{1.97}} │ \textbf{{0.99}} |
| 2023 | Proposed method (eight selected augmentation operations) proposed | MAE | 1.799 | Heart Rate Estimation · split: test · model=TSCAN · augmentation=eight selected operations · training-data=SCAMPS | Training Robust Deep Physiological Measurement Models with Synthetic Video-based DataSource quoteL236: UBFC │ 1.799 │ 3.723 │ 1.928 │ 0.980 |
| 2023 | NEST proposed | HR MAE↓ | 4.7471 bpm | Heart Rate Estimation · split: test · evaluation=MSDG · training-datasets=PURE, BUAA, VIPL, V4V | Neuron Structure Modeling for Generalizable Remote Physiological MeasurementSource quoteL197: NEST │ 0.0597 │ 0.0782 │ 0.2017 │ 0.0597 │ 0.0782 │ 0.2017 │ 0.2138 │ 0.2824 │ 0.3179 │ 4.7471 │ 6.8876 │ 0.8546 |
| 2023 | RoI+Sh+B (U) proposed | MAE | 0.89 | Heart Rate Estimation · method=RoI extraction, shuffling, blurring · key-selection=unbounded randomized | Privacy-Preserving Remote Heart Rate Estimation from Facial VideosSource quoteL188: Ours │ 0.96 │ 1.30 │ 0.99 │ 0.89 │ 1.24 │ 0.99 |
| 2022 | Beam AI SDK proposed | accuracy (heart rate estimation) | 99.2% | Heart Rate Estimation | Real-Time Monitoring of User Stress, Heart Rate and Heart Rate Variability on Mobile DevicesSource quoteL4: Stress is considered to be the epidemic of the 21st-century \cite{Fink2016_StressEpidemic}. Yet, mobile apps cannot directly evaluate the impact of their content and services on user stress. We introduce the Beam AI SDK to address this issue. Using our SDK, apps can monitor user stress through the selfie camera in real-time. Our technology extracts the user’s pulse wave by analyzing subtle color variations across the skin regions of the user’s face. The user’s pulse wave is then used to determine stress (according to the Baevsky Stress Index), heart rate, and heart rate variability. We evaluate our technology on the UBFC dataset, the MMSE-HR dataset, and Beam AI's internal data. Our technology achieves 99.2%, 97.8% and 98.5% accuracy for heart rate estimation on each benchmark respectively, a nearly twice lower error rate than competing methods. We further demonstrate an average Pearson correlation of 0.801 in determining stress and heart rate variability, thus producing commercially useful readings to derive content decisions in apps. Our SDK is available for use\footnote{Visit \url{beamhealth.ai} for more information. The Beam AI SDK (iOS) files can be accessed at \url{github.com/beamai/BeamAISDK-iOS}. SDK access keys can be obtained by signing up at \url{dashboard.beamhealth.ai}.}. |
| 2022 | Beam AI SDK proposed non-standard slice | MAE (heart rate estimation) | 0.65 beats per minute | Heart Rate Estimation · fps=30 FPS · frame-rate=30 fps | Real-Time Monitoring of User Stress, Heart Rate and Heart Rate Variability on Mobile DevicesSource quoteL33: Beam AI SDK │ 0.65 │ 0.77% │ 1.98 │ 0.99 |
| 2022 | FedWeight (signal-quality-weighted averaging) proposed | MAE (HR estimation) | 4.59 beats/min | Heart Rate Estimation · federated · training-data=AFRL · video-noise-level=1.50 | Federated Remote Physiological Measurement with Imperfect DataSource quoteL137: 1.50 │ 7.44 │ 4.59 │ -2.33 │ -0.03 │ 0.66 │ 0.79 |
| 2021 | Paper's contrastive (self-supervised) system proposed non-standard slice | RMSE | 4.6 | Heart Rate Estimation · self-supervised | The Way to my Heart is through Contrastive Learning: Remote Photoplethysmography from Unlabelled VideoSource quoteL217: UBFC. Lastly, we consider the UBFC dataset, comparing against the 7.4 RMSE baseline from~\cite{lee_meta-rppg_2020}. Note they instead use the first two seconds of all samples for adaptation, so the results are not perfectly comparable. Our supervised (4.9 RMSE) and contrastive (4.6 RMSE) methods both achieve a similar, improved performance. |
| 2021 | Paper's supervised system proposed non-standard slice | RMSE | 4.9 | Heart Rate Estimation · supervised | The Way to my Heart is through Contrastive Learning: Remote Photoplethysmography from Unlabelled VideoSource quoteL217: UBFC. Lastly, we consider the UBFC dataset, comparing against the 7.4 RMSE baseline from~\cite{lee_meta-rppg_2020}. Note they instead use the first two seconds of all samples for adaptation, so the results are not perfectly comparable. Our supervised (4.9 RMSE) and contrastive (4.6 RMSE) methods both achieve a similar, improved performance. |
| 2021 | EfficientPhys-C proposed | Pearson correlation | 0.99 | Heart Rate Estimation | EfficientPhys: Enabling Simple, Fast and Accurate Camera-Based Cardiac MeasurementSource quoteL188: To conduct a fair comparison with the current state-of-the-art methods, we followed Dual-GAN \cite{lu2021dual} to train our models in PURE only and to test on UBFC as Table \ref{tab:cross_pure_ubfc} shows. Although Dual-GAN outperforms all of other methods, we argue that the margin is relatively small as both Dual-GAN and EfficientPhys-C achieve a Pearson correlation of 0.99. Moreover, according to American National Standards Institute (ANSI) and Consumer Technology Association's standard \cite{consumer2018physical}, MAPE of ±5 is an acceptable error rate. Various studies have also used this standard to validate FDA approved sensors and systems \cite{nelson2019accuracy,shcherbina2017accuracy,reece2021assessing,carrier2020validity}. All the methods in Table \ref{tab:cross_pure_ubfc} have met this recommended bar. |
| 2020 | MetaPhys, supervised with pretraining proposed | MAE | 1.90 BPM | Heart Rate Estimation · pretraining=with-pretraining · training-regime=supervised | MetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological MeasurementSource quoteL166: Next, we examine the difference between a supervised and unsupervised training regime in MetaPhys\xspace. For UBFC, the supervised model (MAE=1.90 BPM), outperformed the unsupervised model (MAE=2.46 BPM). Whereas, for the MMSE dataset the unsupervised model (MAE=1.87 BMP) outperformed the supervised model (MAE=2.98 BMP). The fact that the unsupervised model achieves broadly comparable results to the supervised model is surprising and encouraging because there are many applications where unsupervised adaptation would be more convenient and efficient (e.g., calibrating a heart rate measurement app on a smartphone without needing a reference device). We also observe that the unsupervised model, even though it used the POS signal as training input, significantly outperforms POS on both datasets, suggesting MetaPhys\xspace is able to form a better representation. |
| 2020 | MetaPhys, unsupervised with pretraining proposed | MAE | 2.46 BPM | Heart Rate Estimation · pretraining=with-pretraining · training-regime=unsupervised | MetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological MeasurementSource quoteL166: Next, we examine the difference between a supervised and unsupervised training regime in MetaPhys\xspace. For UBFC, the supervised model (MAE=1.90 BPM), outperformed the unsupervised model (MAE=2.46 BPM). Whereas, for the MMSE dataset the unsupervised model (MAE=1.87 BMP) outperformed the supervised model (MAE=2.98 BMP). The fact that the unsupervised model achieves broadly comparable results to the supervised model is surprising and encouraging because there are many applications where unsupervised adaptation would be more convenient and efficient (e.g., calibrating a heart rate measurement app on a smartphone without needing a reference device). We also observe that the unsupervised model, even though it used the POS signal as training input, significantly outperforms POS on both datasets, suggesting MetaPhys\xspace is able to form a better representation. |
| 2020 | MetaPhys, unsupervised with pretraining proposed | MAE reduction | 44% | Heart Rate Estimation · pretraining=with-pretraining · training-regime=unsupervised | MetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological MeasurementSource quoteL163: In this section, we compare the performance of MetaPhys\xspace with other state-of-the-art approaches using Mean Absolute Error(MAE) of heart rate. Details of the evaluation metrics are in the Appendix section. For the MMSE dataset, our proposed supervised and unsupervised MetaPhys\xspace with pretraining outperformed the state-of-the-art results by 7% and 42% in MAE, respectively (see Table \ref{tab:AFRL_MMSE}). On the UBFC dataset, supervised and unsupervised MetaPhys\xspace with pretraining showed even greater benefits reducing error by 57% and 44% compared to the previous state-of-the-art, respectively. Meta-learning alone is not as effective as meta-learning using weights initialized in a pretraining stage (19% and 50% improvements in MMSE and UBFC). We also compared our methods against the only other meta-learning based method (Meta-rPPG) where we reduced the MAE by 68%. Furthermore, we compared MetaPhys\xspace against a traditional personalization method (fine-tuning), and our approach gained 54% and a 61% improvements in terms of MAE on MMSE and UBFC, respectively. We also evaluated performance using different time windows in the support set (6s, 12s and 18s), and the results showed training with 18s (RMSE: 3.12) outperformed 6s (RMSE: 5.43) and 12s (RMSE: 5.53) on the MMSE dataset. A similar trend was also observed on the UBFC dataset (RMSE of 18s: 3.12, RMSE of 12s: 4.48, RMSE of 6s: 3.46). Fig. \ref{fig:blandaltman} compares the heart rate estimates from MetaPhys\xspace and the-state-of-art algorithm (TS-CAN \cite{liu2020multi}) (y-axes) to the gold-standard measurements (x-axes). The strong correlation coefficients and bias/limits in the Bland-Altman plots presented support that MetaPhys\xspace can produce more accurate and reliable estimates. Our results from unsupervised MetaPhys\xspace indicate that pesudo labels provided by a relatively simple de-mixing approach (POS) can be used in a meta-learning context to obtain strong results. The training with these pseudo labels, sometimes with noisy labels, well outperforms the de-mixing approach itself. |