# UBFC (`ubfc`)

- **Canonical ID**: `bmk_e9f7d7fc1c6fe43d`
- **Task**: heart-rate-estimation · **Modality**: unspecified
- **Coverage**: 15 papers · 29 observations
- **Tasks Evaluated**: Heart Rate Estimation (`?task=heart-rate-estimation`, 15 papers), Blood Volume Pulse Signal Quality (`?task=blood-volume-pulse-signal-quality`, 1 papers)

## Recent Extracted Observations

| Year | Method | Role | Metric | Score | Split | Regime | Paper | Verbatim Quote |
| --- | --- | --- | --- | ---: | --- | --- | --- | --- |
| 2026 | StreamPPG (frame-wise) | proposed | Throughput | 290 fps | - | - | [StreamPPG: Low-Latency rPPG Estimation via Consistent Privileged Learning](/work/streamppg-low-latency-rppg-estimation-via-consistent) | StreamPPG &F & 2.92 & 1.59 & 290 & 405.75 &0.27 |
| 2026 | StreamPPG (frame-wise) | proposed | RMSE | 0.27 bpm | - | - | [StreamPPG: Low-Latency rPPG Estimation via Consistent Privileged Learning](/work/streamppg-low-latency-rppg-estimation-via-consistent) | StreamPPG &F & 2.92 & 1.59 & 290 & 405.75 &0.27 |
| 2026 | StreamPPG | proposed | RMSE | 0.22 bpm | - | - | [StreamPPG: Low-Latency rPPG Estimation via Consistent Privileged Learning](/work/streamppg-low-latency-rppg-estimation-via-consistent) | StreamPPG & 56 & 0.31 & 54 & 0.27 & 53 & 0.27 & 54 & 0.22 |
| 2025 | CiCi | proposed | MAE | 3.55 | test | test-time-adaptation | [Not Only Consistency: Enhance Test-Time Adaptation with Spatio-temporal Inconsistency for Remote Physiological Measurement](/work/not-only-consistency-enhance-test-time-adaptation) | CiCi & 3.55\(^*\) & 6.27\(^*\) & 0.89 & 4.96\(^*\) & 7.99\(^*\) & 0.90\(^*\) & 1.49\(^*\) & 1.96\(^*\) & 0.99 & 6.87\(^*\) & 10.59\(^*\) & 0.64\(^*\) & 8.58\(^* |
| 2024 | TSCAN-TN | proposed | MAE | 0.519 | - | - | [A Plug-and-Play Temporal Normalization Module for Robust Remote Photoplethysmography](/work/a-plug-and-play-temporal-normalization-module) | The TN module can improve training performance on complex, high-noise real-world datasets. MMPD \cite{tang2023mmpd}, recognized as a challenging dataset for rea |
| 2024 | PhysMLE-R | proposed | HR MAE | 4.353 bpm | test | cross-domain | [PhysMLE: Generalizable and Priors-Inclusive Multi-Task Remote Physiological Measurement](/work/physmle-generalizable-and-priors-inclusive-multi-task-remote) | & PhysMLE-R & 0.056 & 0.073 & 0.248 & 0.056 & 0.073 & 0.248 & 0.223 & 0.296 & 0.345 & 4.353 & 5.081 & 0.850 |
| 2024 | Bi-TTA | proposed | M↓ (MAE) | 3.53 | - | - | [Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement](/work/bi-tta-bidirectional-test-time-adapter-for-remote) | Ours & \textbf{{7.09}}& \textbf{{10.72}}&\textbf{{0.63}}&9.1&11.02&0.54& \textbf{{5.02}} &\textbf{{8.11}}& \textbf{{0.890}}&3.53& 6.24&0.891& \textbf{{1.49}}&\t |
| 2024 | PhysNet + FWD loss | ablation | MAE | 0.83 bpm | test | supervised | [SFDA-rPPG: Source-Free Domain Adaptive Remote Physiological Measurement with Spatio-Temporal Consistency](/work/sfda-rppg-source-free-domain-adaptive-remote-physiological-cn2m) | & & & PURE & 0.83 & 1.73 & 0.99 & 0.22 & 1.05 & 0.99 |
| 2024 | ConPhys | unclear | M↓ (MAE) | 3.92 | - | - | [Bi-TTA: Bidirectional Test-Time Adapter for Remote Physiological Measurement](/work/bi-tta-bidirectional-test-time-adapter-for-remote) | ConPhys\empty^{\ref{fn:conphys}} \cite{sun2022contrast} & 7.43& 10.7& 0.61& 9.3& 10.96& 0.52&6.09& 8.83& 0.88& 3.92& 6.61& 0.886& 1.75& 2.19& 0.97 |
| 2023 | Proposed method (eight selected augmentation operations) | proposed | MAE | 1.799 | test | - | [Training Robust Deep Physiological Measurement Models with Synthetic Video-based Data](/work/training-robust-deep-physiological-measurement-models) | UBFC & 1.799 & 3.723 &1.928 & 0.980 |
| 2023 | NEST | proposed | HR MAE↓ | 4.7471 bpm | test | - | [Neuron Structure Modeling for Generalizable Remote Physiological Measurement](/work/neuron-structure-modeling-for-generalizable-remote) | & NEST & 0.0597 & 0.0782 & 0.2017 & 0.0597 & 0.0782 & 0.2017 & 0.2138 & 0.2824 & 0.3179 & 4.7471 & 6.8876 & 0.8546 |
| 2023 | RoI+Sh+B (U) | proposed | MAE | 0.89 | - | - | [Privacy-Preserving Remote Heart Rate Estimation from Facial Videos](/work/privacy-preserving-remote-heart-rate-estimation-from-facial) | Ours & 0.96 & 1.30 & 0.99 & 0.89 & 1.24 & 0.99 |
| 2022 | Beam AI SDK | proposed | accuracy (heart rate estimation) | 99.2% % | - | - | [Real-Time Monitoring of User Stress, Heart Rate and Heart Rate Variability on Mobile Devices](/work/real-time-monitoring-of-user-stress-heart-rate) | Stress is considered to be the epidemic of the 21st-century \cite{Fink2016_StressEpidemic}. Yet, mobile apps cannot directly evaluate the impact of their conten |
| 2022 | Beam AI SDK | proposed | MAE (heart rate estimation) | 0.65 beats per minute | - | - | [Real-Time Monitoring of User Stress, Heart Rate and Heart Rate Variability on Mobile Devices](/work/real-time-monitoring-of-user-stress-heart-rate) | Beam AI SDK & 0.65 & 0.77% & 1.98 & 0.99 |
| 2022 | FedWeight (signal-quality-weighted averaging) | proposed | MAE (HR estimation) | 4.59 beats/min | - | federated | [Federated Remote Physiological Measurement with Imperfect Data](/work/federated-remote-physiological-measurement-with-imperfect) | & 1.50 & 7.44 & 4.59 & -2.33 & -0.03 & 0.66 & 0.79 |
| 2022 | TS-CAN | baseline | MAE | 6.86 Beats/Min | - | supervised | [rPPG-Toolbox: Deep Remote PPG Toolbox](/work/rppg-toolbox-deep-remote-ppg-toolbox) | TS-CAN~\cite{liu2020multi} & 6.86 & 16.1 & 6.68 & 0.76 & 6.67 & 18.9 & 7.93 & 0.62 |
| 2022 | PhysNet | baseline | MAE | 6.46 Beats/Min | - | supervised | [rPPG-Toolbox: Deep Remote PPG Toolbox](/work/rppg-toolbox-deep-remote-ppg-toolbox) | PhysNet~\cite{yu2019remote}& 6.46 & 12.2 & 6.50 & 0.823 & 19.95 & 27.57 & 0.16 & 31.54 |
| 2022 | DeepPhys | baseline | MAE | 3.83 Beats/Min | - | supervised | [rPPG-Toolbox: Deep Remote PPG Toolbox](/work/rppg-toolbox-deep-remote-ppg-toolbox) | DeepPhys~\cite{chen2018deepphys}& 3.83 & 12.5 & 3.62 & 0.82 & 3.46 & 12.9 & 3.53 & 0.84 |
| 2022 | EfficientPhys-C | baseline | MAE (heart rate estimation) | 1.14 beats per minute | - | - | [Real-Time Monitoring of User Stress, Heart Rate and Heart Rate Variability on Mobile Devices](/work/real-time-monitoring-of-user-stress-heart-rate) | EfficientPhys-C \cite{EfficientPhys_Liu2021} & 1.14 & 1.16% & 1.81 & 0.99 |
| 2022 | FedAvg | baseline | MAE (HR estimation) | 7.44 beats/min | - | federated | [Federated Remote Physiological Measurement with Imperfect Data](/work/federated-remote-physiological-measurement-with-imperfect) | & 1.50 & 7.44 & 4.59 & -2.33 & -0.03 & 0.66 & 0.79 |
| 2021 | Paper's contrastive (self-supervised) system | proposed | RMSE | 4.6 | - | self-supervised | [The Way to my Heart is through Contrastive Learning: Remote Photoplethysmography from Unlabelled Video](/work/the-way-to-my-heart-is-through-contrastive) | UBFC. Lastly, we consider the UBFC dataset, comparing against the 7.4 RMSE baseline from~\cite{lee_meta-rppg_2020}. Note they instead use the first two seconds  |
| 2021 | Paper's supervised system | proposed | RMSE | 4.9 | - | supervised | [The Way to my Heart is through Contrastive Learning: Remote Photoplethysmography from Unlabelled Video](/work/the-way-to-my-heart-is-through-contrastive) | UBFC. Lastly, we consider the UBFC dataset, comparing against the 7.4 RMSE baseline from~\cite{lee_meta-rppg_2020}. Note they instead use the first two seconds  |
| 2021 | EfficientPhys-C | proposed | Pearson correlation | 0.99 | - | - | [EfficientPhys: Enabling Simple, Fast and Accurate Camera-Based Cardiac Measurement](/work/efficientphys-enabling-simple-fast-and-accurate-camera-based-sjk2) | To conduct a fair comparison with the current state-of-the-art methods, we followed Dual-GAN \cite{lu2021dual} to train our models in PURE only and to test on U |
| 2021 | Dual-GAN | unclear | Pearson correlation | 0.99 | - | - | [EfficientPhys: Enabling Simple, Fast and Accurate Camera-Based Cardiac Measurement](/work/efficientphys-enabling-simple-fast-and-accurate-camera-based-sjk2) | To conduct a fair comparison with the current state-of-the-art methods, we followed Dual-GAN \cite{lu2021dual} to train our models in PURE only and to test on U |
| 2020 | MetaPhys, supervised with pretraining | proposed | MAE | 1.90 BPM | - | - | [MetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological Measurement](/work/metaphys-unsupervised-few-shot-adaptation-for-non-contact) | Next, we examine the difference between a supervised and unsupervised training regime in MetaPhys\xspace. For UBFC, the supervised model (MAE=1.90 BPM), outperf |
| 2020 | MetaPhys, unsupervised with pretraining | proposed | MAE | 2.46 BPM | - | - | [MetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological Measurement](/work/metaphys-unsupervised-few-shot-adaptation-for-non-contact) | Next, we examine the difference between a supervised and unsupervised training regime in MetaPhys\xspace. For UBFC, the supervised model (MAE=1.90 BPM), outperf |
| 2020 | MetaPhys, unsupervised with pretraining | proposed | MAE reduction | 44% % | - | - | [MetaPhys: Unsupervised Few-Shot Adaptation for Non-Contact Physiological Measurement](/work/metaphys-unsupervised-few-shot-adaptation-for-non-contact) | In this section, we compare the performance of MetaPhys\xspace with other state-of-the-art approaches using Mean Absolute Error(MAE) of heart rate. Details of t |