UBFC · Heart Rate Estimation
15 papers · 29 extracted observations · heart rate estimation · Markdown · CSV · JSON API
Metricmae (19)rmse (4)bvp signal to noise ratio snr (2)pearson correlation (2)accuracy (1)throughput (1)
Splittest (5)
Showing 1 of 1 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2021 | Paper's contrastive (self-supervised) system proposed non-standard slice | RMSE | 4.6 | Heart Rate Estimation · self-supervised | The Way to my Heart is through Contrastive Learning: Remote Photoplethysmography from Unlabelled VideoSource quoteL217: UBFC. Lastly, we consider the UBFC dataset, comparing against the 7.4 RMSE baseline from~\cite{lee_meta-rppg_2020}. Note they instead use the first two seconds of all samples for adaptation, so the results are not perfectly comparable. Our supervised (4.9 RMSE) and contrastive (4.6 RMSE) methods both achieve a similar, improved performance. |