TID2013 · Image Quality Assessment
51 papers · 100 extracted observations · image quality assessment · vision · Markdown · CSV · JSON API
Tasks on TID2013All tasks (51)Image Quality Assessment (50)Blind Image Quality Assessment (1)Image Distortion Classification (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Image Quality Assessment: proposed/measured results on test (including papers where test split is standard/implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Gamma (MoAE-equipped; task-specific training) SOTA frontier | 0.944 | 2025-03-01 | training=task-specific · Task-specific training and testing with the fixed naive prompt. | Gamma: Toward Generic Image Assessment with Mixture of Assessment ExpertsSource quoteTask-specific Training. We apply our method to 12 image assessment datasets. We use the fixed naive prompt (described in Section~\ref{sec:overview}) for training and testing. We observe that our method outperforms all others methods by a significant margin. On some benchmark, our method achieve dramatic improvements, such as SRCC of 0.944 (v.s. 0.916) on TID2013 and 0.945 (v.s. 0.933) on KonIQ. Since images in these 12 datasets encompass a wide variety of contents and distortion types, it is particularly challenging to consistently achieve the leading performance on all of them. |
| 2 | UniQA SOTA frontier | 0.916 | 2024-06-01 | inference-patches=10 · IQA comparison table; per-dataset downstream adapter fine-tuning. Inference averages … | UniQA: Unified Vision-Language Pre-training for Image Quality and Aesthetic AssessmentSource quoteOurs │ 0.916 │ 0.931 │ 0.963 │ 0.973 │ 0.940 │ 0.943 │ 0.890 │ 0.905 │ 0.933 │ 0.941 │ 0.924 │ 0.928 |
| 3 | HarmonyIQA (NR) | 0.901 | 2025-01-01 | evaluation=no-reference · split-ratio=4:1 train/test · 4:1 train/test split. | HarmonyIQA: Pioneering Benchmark and Model for Image Harmonization Quality AssessmentSource quoteHarmonyIQA │ \textcolor{mred}{0.968} │ \textcolor{mred}{0.977} │ \textcolor{mred}{0.901} │ \textcolor{mred}{0.913} │ \textcolor{mred}{0.935} │ \textcolor{mred}{0.938} |
| 4 | Causal Disentanglement, Ours w/ (f) | 0.899 | 2026-04-01 | training=supervised-mos · Pre-trained on the Waterloo-based synthetic degraded dataset, fine-tuned on the targe… | Causal Disentanglement-Inspired Degradation Representation Learning for Full-Reference Image Quality AssessmentSource quoteOurs w/ (f) │ \textcolor{blue}{0.968} │ \textcolor{red}{0.966} │ \textcolor{red}{0.966} │ 0.954 │ \textcolor{red}{0.916} │ \textcolor{red}{0.899} │ \textcolor{red}{0.902} │ 0.897 │ \textcolor{blue}{0.727 (f)} │ \textcolor{blue}{0.713 (f)} |
| 5 | MSTRIQ SOTA frontier | 0.882 | 2022-05-01 | Models trained and tested on each dataset respectively; overall performance evaluatio… | MSTRIQ: No Reference Image Quality Assessment Based on Swin Transformer with Multi-Stage FusionSource quoteOurs │ 0.954 │ 0.946 │ 0.895 │ 0.882 |
| 6 | BPSQM, MD PM (MDSI gradient and chromaticity similarity-map labels) SOTA frontier (+1 variant) | 0.863 | 2018-01-01 | label-variant=MDSI gradient and chromaticity similarity maps · All distortion types; quality-map-label variant in Table 2. | Blind Predicting Similar Quality Map for Image Quality AssessmentSource quote0.863 |
| 7 | QAIRN (Q2 from γ2) | 0.862 | 2023-11-01 | pooling=Minkowski · attention-map=γ2 · quality-estimate=Q2 · Minkowski-pooled quality estimate Q2 from the γ2 attention map; correlation with huma… | Joint Deep Image Restoration and Unsupervised Quality AssessmentSource quote\(Q_2\), from \(\gamma_2\) │ 0.880 │ 0.862 │ 0.658 |
| 8 | Proposed BIQA method (Ours, All databases) | 0.855 | 2020-01-01 | resolution=original image size · training-data=all six IQA databases · Trained on all six IQA databases using intra-database image pairs; tested at original… | Learning To Blindly Assess Image Quality In The Laboratory And WildSource quoteOurs (All databases) │ {\bf 0.961} │ {\bf 0.907} │ {\bf 0.855} │ {\bf 0.863} │ {\bf 0.851} │ {\bf 0.894} |
| 9 | MQAF-R | 0.847 | 2026-02-01 | Cross-dataset evaluation: trained on KADID-10K and tested on TID2013, without fine-tu… | Image Quality Assessment: Exploring Quality Awareness via Memory-driven Distortion Patterns MatchingSource quoteMQAF-R (Ours) │ \bf 0.913 │ \bf0.941 │ \bf 0.903 │ 0.910 │ \bf0.845 │ \bf 0.847 |
| 10 | SWDN* (+1 variant) | 0.8187 | 2020-11-01 | Trained on the PIPAL training set; evaluated on TID2013. | Image Quality Assessment for Perceptual Image Restoration: A New Dataset, Benchmark and MetricSource quote0.8187 │ 0.6335 |
| 11 | DB-CNN | 0.816 | 2019-07-01 | Per-database score from the ablation-results table; the cited lines do not specify th… | Blind Image Quality Assessment Using A Deep Bilinear Convolutional Neural NetworkSource quoteDB-CNN │ {\bf 0.968} │ {\bf0.946} │ {\bf 0.816} │ {\bf 0.851} |
| 12 | CVRKD-IQA NAR-student (NAR + KD) | 0.691 | 2022-01-01 | runs=10 · reference=misaligned reference images · training-data=KADID-10K · Cross-dataset evaluation after training on synthetic Kaddid-10K; NAR and KD enabled. … | Content-Variant Reference Image Quality Assessment via Knowledge DistillationSource quoteNAR-student w/ KD │ \checkmark │ \checkmark │ 0.691 ± 0.003 │ 0.416 ± 0.004 |
| 13 | DiffV^2IQA | 0.652 | 2025-01-01 | evaluation=cross-dataset · training-dataset=PIPAL · Cross-dataset test: trained on PIPAL and tested on TID2013; table reports PLCC then S… | Diffusion Model-Based Visual Compensation Guidance and Visual Difference Analysis for No-Reference Image Quality AssessmentSource quoteDiffV^2IQA │ 0.769 │ 0.805 │ 0.729 │ 0.652 |
| 14 | Magnitude-Aware CLIP (MA-CLIP) | 0.599 | 2025-11-01 | backbone=CLIP · Reported benchmark evaluation; training-free, with no task-specific training. | Beyond Cosine Similarity Magnitude-Aware CLIP for No-Reference Image Quality AssessmentSource quoteOn synthetic distortion datasets of CSIQ, our method outperforms existing opinion-unaware baselines and CLIP-based models by a large margin. For instance, on TID2013, MA-CLIP achieves an SRCC of 0.599, surpassing CLIP-IQA by 3.5%. This improvement reflects the benefit of incorporating distortion-sensitive features via our normalized magnitude modeling, which enhances the model’s ability to detect subtle degradation patterns often present in synthetic benchmarks. |
Other primary task on TID2013: Image Quality Assessment · SROCC ↑ · test (10 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | WaDIQaM-FR SOTA frontier | 0.94 | 2018-01-01 | evaluation=all distortion types; 10 random splits · reference-type=full-reference · patches-per-image=32 · Full TID2013 evaluation, retaining all distortion types; 32 patches per image; split … | Deep Neural Networks for No-Reference and Full-Reference Image Quality AssessmentSource quote\bf{0.946} │ \bf{0.940} |
| 2 | QualNet (proposed) | 0.89 | 2020-06-01 | — | No-Reference Image Quality Assessment via Feature Fusion and Multi-Task LearningSource quoteQualNet (proposed) │ 0.980 │ 0.984 │ 0.907 │ 0.921 │ 0.890 │ 0.901 │ 0.961 │ 0.965 │ 0.960 │ 0.952 │ 0.938 │ 0.943\tabularnewline |
| 3 | VTAMIQ (+1 variant) | 0.874 | 2021-10-01 | Cross-database evaluation; trained on LIVE and tested on TID2013. | VTAMIQ: Transformers for Attention Modulated Image Quality AssessmentSource quoteVTAMIQ (ours) │ 0.874 │ 0.899 │ 0.957 │ 0.907 │ 0.974 │ 0.897 |
| 4 | MetaIQA (+1 variant) | 0.8539 | 2020-01-01 | Leave-one-distortion-out cross-validation: train on N−1 distortion types and test on … | MetaIQA: Deep Meta-Learning for No-Reference Image Quality AssessmentSource quoteAverage │ 0.5322 │ 0.5950 │ 0.5701 │ 0.5465 │ 0.4725 │ 0.7073 │ 0.8539 |
| 5 | CONTRIQUE | 0.843 | 2021-10-01 | Synthetic-distortion benchmark; unsupervised pretraining with linear regression and a… | Image Quality Assessment using Contrastive LearningSource quote\multirow{2}{*}{CONTRIQUE} │ \multirow{2}{*}{\shortstack[c]{Unsupervised pretraining and Linear Regression}} │ \multirow{2}{*}{0.960} │ \multirow{2}{*}{0.961} │ \multirow{2}{*}{0.942} │ \multirow{2}{*}{0.955} │ \multirow{2}{*}{0.843} │ \multirow{2}{*}{0.857} │ \multirow{2}{*}{0.934} │ \multirow{2}{*}{0.937} |
| 6 | DA-IQA | 0.828 | 2019-11-01 | Entire TID2013 evaluation; ALL means testing all distortions together. Reported value… | Domain-Aware No-Reference Image Quality AssessmentSource quoteDA-IQA │ 0.477 │ 0.695 │ 0.438 │ 0.674 │ 0.709 │ 0.852 │ 0.713 │ 0.897 │ 0.808 │ 0.774 │ 0.868 │ 0.828 |
| 7 | RADN | 0.747 | 2021-01-01 | training_data=PIPAL · Cross-dataset evaluation; trained on the PIPAL training set and tested on the full TI… | Region-Adaptive Deformable Network for Image Quality AssessmentSource quoteRADN │ 0.747 │ 0.796 │ 0.905 │ 0.878 |
| 8 | RankIQA (VGG-16) SOTA frontier | 0.623 | 2017-01-01 | runs=10 · backbone=VGG-16 · training=generated ranking data · distortions=all · split_protocol=80/20 by reference images · All distortions combined; trained on generated ranking data without fine-tuning on TI… | RankIQA: Learning from Rankings for No-Reference Image Quality AssessmentSource quoteRankIQA │ 0.463 │ 0.693 │ 0.321 │ 0.657 │ 0.622 │ 0.845 │ 0.609 │ 0.891 │ 0.788 │ 0.727 │ \multicolumn{1}{c|}{0.768} │ \multicolumn{2}{c}{0.623} |
| 9 | SaTQA (proposed) | 0.617 | 2024-01-01 | evaluation=cross-dataset · training-dataset=LIVE · Cross-dataset evaluation: train on LIVE, test on TID2013 without parameter tuning; re… | Transformer-Based No-Reference Image Quality Assessment via Supervised Contrastive LearningSource quoteProposed │ 0.791 │ 0.788 │ 0.831 │ 0.617 |
| 10 | Life-IQA | 0.453 | 2026-01-01 | Cross-dataset evaluation: trained on KonIQ and tested on TID2013. | Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature DecouplingSource quoteLife-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}} |
Other primary task on TID2013: Image Quality Assessment · PLCC ↑ (8 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | UniQA SOTA frontier | 0.931 | 2024-06-01 | inference-patches=10 · IQA comparison table; per-dataset downstream adapter fine-tuning. Inference averages … | UniQA: Unified Vision-Language Pre-training for Image Quality and Aesthetic AssessmentSource quoteOurs │ 0.916 │ 0.931 │ 0.963 │ 0.973 │ 0.940 │ 0.943 │ 0.890 │ 0.905 │ 0.933 │ 0.941 │ 0.924 │ 0.928 |
| 2 | LGDM-\psi_{\text{SDv1.5}} | 0.921 | 2025-06-01 | Stable Diffusion v1.5 used as the perceptual metric with intermediate features; 10 DD… | Latent Guidance in Diffusion Models for Perceptual EvaluationsSource quoteTable~\ref{tab:synthetic_scores} reports the PLCC and SRCC scores of LGDM and existing NR-IQA methods on four synthetic datasets: LIVE \cite{sheikh2006statistical}, CSIQ \cite{larson2010most}, TID2013 \cite{ponomarenko2013color}, and KADID \cite{lin2019kadid}. The results demonstrate that our proposed approach outperforms other methods across almost all datasets. Similar to the performance on authentic distortion dataset in Table~\ref{tab:authentic_scores}, LGDM-\psi-SDv1.5 achieves the best performance across all synthetic datasets, indicating a strong alignment with human perceptual judgments. The results also suggest that perceptual guidance using \psi-Re-IQA and \psi-SDv1.5 consistently enhances the model's generalization capabilities. The superior performance of LGDM-\psi-SDv1.5 on the TID2013 \cite{ponomarenko2013color}and KADID \cite{lin2019kadid} datasets, with PLCC and SRCC scores of 0.921/0.883 and 0.961/0.958, respectively, underscores the value of utilizing diffusion hyperfeatures. Additional results are provided in Appendix~\ref{appendix:results}. |
| 3 | LGDM-ψSDv1.5 | 0.921 | 2025-01-01 | params=5B · steps=10 DDIM · backbone=Stable Diffusion v1.5 · distortion=synthetic · Uses Stable Diffusion v1.5 as the perceptual metric and feeds its intermediate featur… | LGDM: Latent Guidance in Diffusion Models for Perceptual EvaluationsSource quote2019) datasets, with PLCC and SRCC scores of 0.921/0.883 and 0.961/0.958, respectively, underscores the value of utilizing diffusion hyperfeatures. Additional results are provided in Appendix D. |
| 4 | Causal Disentanglement, Ours w/ (f) | 0.916 | 2026-04-01 | training=supervised-mos · Pre-trained on the Waterloo-based synthetic degraded dataset, fine-tuned on the targe… | Causal Disentanglement-Inspired Degradation Representation Learning for Full-Reference Image Quality AssessmentSource quoteOurs w/ (f) │ \textcolor{blue}{0.968} │ \textcolor{red}{0.966} │ \textcolor{red}{0.966} │ 0.954 │ \textcolor{red}{0.916} │ \textcolor{red}{0.899} │ \textcolor{red}{0.902} │ 0.897 │ \textcolor{blue}{0.727 (f)} │ \textcolor{blue}{0.713 (f)} |
| 5 | DEIQT | 0.908 | 2024-06-01 | Overall-results table comparator; its specific evaluation protocol is unstated in the… | Local Manifold Learning for No-Reference Image Quality AssessmentSource quoteImage Quality Assessment (IQA) methods typically overlook local manifold structures, leading to compromised discriminative capabilities in perceptual quality evaluation. To address this limitation, we present LML-IQA, an innovative no-reference IQA (NR-IQA) approach that leverages a combination of local manifold learning and contrastive learning. Our approach first extracts multiple patches from each image and identifies the most visually salient region. This salient patch serves as a positive sample for contrastive learning, while other patches from the same image are treated as intra-class negatives to preserve local distinctiveness. Patches from different images also act as inter-class negatives to enhance feature separation. Additionally, we introduce a mutual learning strategy to improve the model’s ability to recognize and prioritize visually important regions. Comprehensive experiments across eight benchmark datasets demonstrate significant performance gains over state-of-the-art methods, achieving a PLCC of 0.942 on TID2013 (compared to 0.908) and 0.977 on CSIQ (compared to 0.965). |
| 6 | MSTRIQ SOTA frontier | 0.895 | 2022-05-01 | Models trained and tested on each dataset respectively; overall performance evaluatio… | MSTRIQ: No Reference Image Quality Assessment Based on Swin Transformer with Multi-Stage FusionSource quoteOurs │ 0.954 │ 0.946 │ 0.895 │ 0.882 |
| 7 | BPSQM, MD PM (MDSI gradient and chromaticity similarity-map labels) SOTA frontier (+1 variant) | 0.879 | 2018-01-01 | label-variant=MDSI gradient and chromaticity similarity maps · All distortion types; quality-map-label variant in Table 2. | Blind Predicting Similar Quality Map for Image Quality AssessmentSource quote0.879 |
| 8 | DeepWSD w/P4 | 0.8697 | 2022-08-01 | patch-size=4×4 · Patch size 4×4 (P4); quality-prediction evaluation. | DeepWSD: Projecting Degradations in Perceptual Space to Wasserstein Distance in Deep Feature SpaceSource quoteDeepWSD w/P4 │ 0.8697 │ 0.8741 │ 0.6932 │ 0.9609 │ 0.9624 │ 0.8378 │ 0.9503 │ 0.9652 │ 0.8297 │ 0.8434 │ 0.8883 │ 0.7076 |
Other primary task on TID2013: Image Quality Assessment · PCC ↑ (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | SOS-H-rNSE SOTA frontier | 0.937 | 2015-10-01 | distortions=JP2K, JPEG, WN, GB · Common distortion types JP2K, JPEG, WN, and GB; SOS-H-rNSE configuration. | Learn to Evaluate Image Perceptual Quality Blindly from Statistics of Self-similaritySource quoteFrom TABLE~\ref{Table_2}, we can observe that both SOS-MD and SOS-H show good performance on the three databases in terms of PCC and SRC. The best results on all the three databases are achieved by the method SOS-H-rNSE, with PCC values 0.946, 0.933, and 0.937 on the three databases, respectively. For every single distortion type, it also demonstrates PCC and SRC values consistently higher than 0.9. Note that due to the scale difference of subjective scores on the three databases, the resulting RMSE values range differently. |
| 2 | QAIRN (Q2 from γ2) | 0.88 | 2023-11-01 | pooling=Minkowski · attention-map=γ2 · quality-estimate=Q2 · Minkowski-pooled quality estimate Q2 from the γ2 attention map; correlation with huma… | Joint Deep Image Restoration and Unsupervised Quality AssessmentSource quote\(Q_2\), from \(\gamma_2\) │ 0.880 │ 0.862 │ 0.658 |
Other primary task on TID2013: Image Quality Assessment · PLCC ↑ · test (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | LML-IQA SOTA frontier | 0.942 | 2024-06-01 | Overall dataset result; the paper reports final metrics as averages over 10 independe… | Local Manifold Learning for No-Reference Image Quality AssessmentSource quoteImage Quality Assessment (IQA) methods typically overlook local manifold structures, leading to compromised discriminative capabilities in perceptual quality evaluation. To address this limitation, we present LML-IQA, an innovative no-reference IQA (NR-IQA) approach that leverages a combination of local manifold learning and contrastive learning. Our approach first extracts multiple patches from each image and identifies the most visually salient region. This salient patch serves as a positive sample for contrastive learning, while other patches from the same image are treated as intra-class negatives to preserve local distinctiveness. Patches from different images also act as inter-class negatives to enhance feature separation. Additionally, we introduce a mutual learning strategy to improve the model’s ability to recognize and prioritize visually important regions. Comprehensive experiments across eight benchmark datasets demonstrate significant performance gains over state-of-the-art methods, achieving a PLCC of 0.942 on TID2013 (compared to 0.908) and 0.977 on CSIQ (compared to 0.965). |
| 2 | Life-IQA | 0.578 | 2026-01-01 | Cross-dataset evaluation: trained on KonIQ and tested on TID2013. | Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature DecouplingSource quoteLife-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}} |
TaskImage Quality Assessment (96)Blind Image Quality Assessment (2)Image Distortion Classification (2)
Metricsrcc (29)plcc (27)srocc (17)lcc (3)spearman s rank correlation coefficients srcc (3)stress (2)lcc mean score (2)
Showing 96 of 96 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Causal Disentanglement, Ours w/ (f) proposed | PLCC | 0.916 | Image Quality Assessment · fine-tuned · training=supervised-mos | Causal Disentanglement-Inspired Degradation Representation Learning for Full-Reference Image Quality AssessmentSource quoteL366: Ours w/ (f) │ \textcolor{blue}{0.968} │ \textcolor{red}{0.966} │ \textcolor{red}{0.966} │ 0.954 │ \textcolor{red}{0.916} │ \textcolor{red}{0.899} │ \textcolor{red}{0.902} │ 0.897 │ \textcolor{blue}{0.727 (f)} │ \textcolor{blue}{0.713 (f)} |
| 2026 | Causal Disentanglement, Ours w/ (f) proposed | SRCC | 0.899 | Image Quality Assessment · fine-tuned · training=supervised-mos | Causal Disentanglement-Inspired Degradation Representation Learning for Full-Reference Image Quality AssessmentSource quoteL366: Ours w/ (f) │ \textcolor{blue}{0.968} │ \textcolor{red}{0.966} │ \textcolor{red}{0.966} │ 0.954 │ \textcolor{red}{0.916} │ \textcolor{red}{0.899} │ \textcolor{red}{0.902} │ 0.897 │ \textcolor{blue}{0.727 (f)} │ \textcolor{blue}{0.713 (f)} |
| 2026 | MQAF-R proposed | SRCC | 0.847 | Image Quality Assessment · fine-tuned | Image Quality Assessment: Exploring Quality Awareness via Memory-driven Distortion Patterns MatchingSource quoteL262: MQAF-R (Ours) │ \bf 0.913 │ \bf0.941 │ \bf 0.903 │ 0.910 │ \bf0.845 │ \bf 0.847 |
| 2025 | HarmonyIQA (NR) proposed | SRCC | 0.901 | Image Quality Assessment · split: test · evaluation=no-reference · split-ratio=4:1 train/test | HarmonyIQA: Pioneering Benchmark and Model for Image Harmonization Quality AssessmentSource quoteL248: HarmonyIQA │ \textcolor{mred}{0.968} │ \textcolor{mred}{0.977} │ \textcolor{mred}{0.901} │ \textcolor{mred}{0.913} │ \textcolor{mred}{0.935} │ \textcolor{mred}{0.938} |
| 2025 | Life-IQA proposed | SROCC | 0.453 | Image Quality Assessment · split: test | Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature DecouplingSource quoteL239: Life-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}} |
| 2025 | Life-IQA proposed | PLCC | 0.578 | Image Quality Assessment · split: test | Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature DecouplingSource quoteL239: Life-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}} |
| 2025 | Gamma (MoAE-equipped; task-specific training) proposed | SRCC | 0.944 | Image Quality Assessment · split: test · fine-tuned · training=task-specific | Gamma: Toward Generic Image Assessment with Mixture of Assessment ExpertsSource quoteL235: Task-specific Training. We apply our method to 12 image assessment datasets. We use the fixed naive prompt (described in Section~\ref{sec:overview}) for training and testing. We observe that our method outperforms all others methods by a significant margin. On some benchmark, our method achieve dramatic improvements, such as SRCC of 0.944 (v.s. 0.916) on TID2013 and 0.945 (v.s. 0.933) on KonIQ. Since images in these 12 datasets encompass a wide variety of contents and distortion types, it is particularly challenging to consistently achieve the leading performance on all of them. |
| 2025 | LGDM-ψSDv1.5 proposed | PLCC | 0.921 | Image Quality Assessment · params=5B · steps=10 DDIM · backbone=Stable Diffusion v1.5 · distortion=synthetic | LGDM: Latent Guidance in Diffusion Models for Perceptual EvaluationsSource quoteL649: 2019) datasets, with PLCC and SRCC scores of 0.921/0.883 and 0.961/0.958, respectively, underscores the value of utilizing diffusion hyperfeatures. Additional results are provided in Appendix D. |
| 2025 | Magnitude-Aware CLIP (MA-CLIP) proposed | SRCC | 0.599 | Image Quality Assessment · backbone=CLIP | Beyond Cosine Similarity Magnitude-Aware CLIP for No-Reference Image Quality AssessmentSource quoteL206: On synthetic distortion datasets of CSIQ, our method outperforms existing opinion-unaware baselines and CLIP-based models by a large margin. For instance, on TID2013, MA-CLIP achieves an SRCC of 0.599, surpassing CLIP-IQA by 3.5%. This improvement reflects the benefit of incorporating distortion-sensitive features via our normalized magnitude modeling, which enhances the model’s ability to detect subtle degradation patterns often present in synthetic benchmarks. |
| 2025 | LGDM-\psi_{\text{SDv1.5}} | PLCC | 0.921 | Image Quality Assessment | Latent Guidance in Diffusion Models for Perceptual EvaluationsSource quoteL292: Table~\ref{tab:synthetic_scores} reports the PLCC and SRCC scores of LGDM and existing NR-IQA methods on four synthetic datasets: LIVE \cite{sheikh2006statistical}, CSIQ \cite{larson2010most}, TID2013 \cite{ponomarenko2013color}, and KADID \cite{lin2019kadid}. The results demonstrate that our proposed approach outperforms other methods across almost all datasets. Similar to the performance on authentic distortion dataset in Table~\ref{tab:authentic_scores}, LGDM-\psi-SDv1.5 achieves the best performance across all synthetic datasets, indicating a strong alignment with human perceptual judgments. The results also suggest that perceptual guidance using \psi-Re-IQA and \psi-SDv1.5 consistently enhances the model's generalization capabilities. The superior performance of LGDM-\psi-SDv1.5 on the TID2013 \cite{ponomarenko2013color}and KADID \cite{lin2019kadid} datasets, with PLCC and SRCC scores of 0.921/0.883 and 0.961/0.958, respectively, underscores the value of utilizing diffusion hyperfeatures. Additional results are provided in Appendix~\ref{appendix:results}. |
| 2024 | DiffV^2IQA proposed | SRCC | 0.652 | Image Quality Assessment · split: test · evaluation=cross-dataset · training-dataset=PIPAL | Diffusion Model-Based Visual Compensation Guidance and Visual Difference Analysis for No-Reference Image Quality AssessmentSource quoteL379: DiffV^2IQA │ 0.769 │ 0.805 │ 0.729 │ 0.652 |
| 2024 | UniQA proposed | SRCC | 0.916 | Image Quality Assessment · fine-tuned · inference-patches=10 | UniQA: Unified Vision-Language Pre-training for Image Quality and Aesthetic AssessmentSource quoteL689: Ours │ 0.916 │ 0.931 │ 0.963 │ 0.973 │ 0.940 │ 0.943 │ 0.890 │ 0.905 │ 0.933 │ 0.941 │ 0.924 │ 0.928 |
| 2024 | UniQA proposed | PLCC | 0.931 | Image Quality Assessment · fine-tuned · inference-patches=10 | UniQA: Unified Vision-Language Pre-training for Image Quality and Aesthetic AssessmentSource quoteL689: Ours │ 0.916 │ 0.931 │ 0.963 │ 0.973 │ 0.940 │ 0.943 │ 0.890 │ 0.905 │ 0.933 │ 0.941 │ 0.924 │ 0.928 |
| 2024 | PromptIQA (MDT) proposed | PLCC | 0.5992 | Image Quality Assessment · split: test · few-shot · label-generation=SSIM | PromptIQA: Boosting the Performance and Generalization for No-Reference Image Quality Assessment via PromptsSource quoteL197: \multicolumn{1}{c|}{\multirow{-2}{*}{PromptIQA}} │ MDT │ Few-shot │ 0.5992 │ 0.8802 │ 0.8064 │ 0.5717 │ 0.7196 │ 0.7615 |
| 2024 | PromptIQA (MDT) proposed | PLCC | 0.8802 | Image Quality Assessment · split: test · few-shot · label-generation=FSIM | PromptIQA: Boosting the Performance and Generalization for No-Reference Image Quality Assessment via PromptsSource quoteL197: \multicolumn{1}{c|}{\multirow{-2}{*}{PromptIQA}} │ MDT │ Few-shot │ 0.5992 │ 0.8802 │ 0.8064 │ 0.5717 │ 0.7196 │ 0.7615 |
| 2024 | PromptIQA (MDT) proposed | PLCC | 0.8064 | Image Quality Assessment · split: test · few-shot · label-generation=LPIPS | PromptIQA: Boosting the Performance and Generalization for No-Reference Image Quality Assessment via PromptsSource quoteL197: \multicolumn{1}{c|}{\multirow{-2}{*}{PromptIQA}} │ MDT │ Few-shot │ 0.5992 │ 0.8802 │ 0.8064 │ 0.5717 │ 0.7196 │ 0.7615 |
| 2024 | ExIQA proposed | SRCC | 0.8237 | Image Quality Assessment · split: test · 0-shot | ExIQA: Explainable Image Quality Assessment Using Distortion AttributesSource quoteL273: ExIQA │ TID2013 │ 0.8237 |
| 2024 | AMqF proposed | PLCC | 0.830 | Image Quality Assessment · cross-database · adaptation=none · training-dataset=KADID-10k | Image Quality Assessment: Exploring Regional Heterogeneity via Response of Adaptive Multiple Quality Factors in Dictionary SpaceSource quoteL117: AMqF (ours) │ \bf 0.907 │ \bf0.926 │ \bf 0.866 │ \bf0.862 │ \bf 0.830 │ \bf 0.815 |
| 2024 | AMqF proposed | SRCC | 0.815 | Image Quality Assessment · cross-database · adaptation=none · training-dataset=KADID-10k | Image Quality Assessment: Exploring Regional Heterogeneity via Response of Adaptive Multiple Quality Factors in Dictionary SpaceSource quoteL117: AMqF (ours) │ \bf 0.907 │ \bf0.926 │ \bf 0.866 │ \bf0.862 │ \bf 0.830 │ \bf 0.815 |
| 2024 | Our-VGG, φ = φγ (causal-effect weights) ablation | PLCC | 0.909 | Image Quality Assessment · backbone=VGG · component=causal-effect weights | Image Quality Assessment: Investigating Causal Perceptual Effects with Abductive Counterfactual InferenceSource quoteL303: 0.929 │ 0.932 │ 0.949 │ 0.952 │ 0.909 │ 0.884 |
| 2024 | Our-VGG, φ = φη (residual component excluding causal effect) ablation | PLCC | 0.786 | Image Quality Assessment · backbone=VGG · component=residual component excluding causal effect | Image Quality Assessment: Investigating Causal Perceptual Effects with Abductive Counterfactual InferenceSource quoteL305: 0.843 │ 0.866 │ 0.803 │ 0.831 │ 0.786 │ 0.789 |
| 2024 | LML-IQA | PLCC | 0.942 | Image Quality Assessment · split: test | Local Manifold Learning for No-Reference Image Quality AssessmentSource quoteL9: Image Quality Assessment (IQA) methods typically overlook local manifold structures, leading to compromised discriminative capabilities in perceptual quality evaluation. To address this limitation, we present LML-IQA, an innovative no-reference IQA (NR-IQA) approach that leverages a combination of local manifold learning and contrastive learning. Our approach first extracts multiple patches from each image and identifies the most visually salient region. This salient patch serves as a positive sample for contrastive learning, while other patches from the same image are treated as intra-class negatives to preserve local distinctiveness. Patches from different images also act as inter-class negatives to enhance feature separation. Additionally, we introduce a mutual learning strategy to improve the model’s ability to recognize and prioritize visually important regions. Comprehensive experiments across eight benchmark datasets demonstrate significant performance gains over state-of-the-art methods, achieving a PLCC of 0.942 on TID2013 (compared to 0.908) and 0.977 on CSIQ (compared to 0.965). |
| 2024 | DEIQT | PLCC | 0.908 | Image Quality Assessment | Local Manifold Learning for No-Reference Image Quality AssessmentSource quoteL9: Image Quality Assessment (IQA) methods typically overlook local manifold structures, leading to compromised discriminative capabilities in perceptual quality evaluation. To address this limitation, we present LML-IQA, an innovative no-reference IQA (NR-IQA) approach that leverages a combination of local manifold learning and contrastive learning. Our approach first extracts multiple patches from each image and identifies the most visually salient region. This salient patch serves as a positive sample for contrastive learning, while other patches from the same image are treated as intra-class negatives to preserve local distinctiveness. Patches from different images also act as inter-class negatives to enhance feature separation. Additionally, we introduce a mutual learning strategy to improve the model’s ability to recognize and prioritize visually important regions. Comprehensive experiments across eight benchmark datasets demonstrate significant performance gains over state-of-the-art methods, achieving a PLCC of 0.942 on TID2013 (compared to 0.908) and 0.977 on CSIQ (compared to 0.965). |
| 2023 | CD-Flow proposed non-standard slice | STRESS | 14.110 | Image Quality Assessment · compressed · subset=quantization noise, color quantization with dither, chromatic aberration | Learning a Deep Color Difference Metric for Photographic ImagesSource quoteL287: CD-Flow │ 14.110 │ 0.837 │ 0.832 |
| 2023 | CD-Flow proposed non-standard slice | PLCC | 0.837 | Image Quality Assessment · compressed · subset=quantization noise, color quantization with dither, chromatic aberration · protocol=four-parameter monotonic linearization | Learning a Deep Color Difference Metric for Photographic ImagesSource quoteL287: CD-Flow │ 14.110 │ 0.837 │ 0.832 |
| 2023 | CD-Flow proposed non-standard slice | SRCC | 0.832 | Image Quality Assessment · compressed · subset=quantization noise, color quantization with dither, chromatic aberration | Learning a Deep Color Difference Metric for Photographic ImagesSource quoteL287: CD-Flow │ 14.110 │ 0.837 │ 0.832 |
| 2023 | QAIRN (Q2 from γ2) proposed | PCC | 0.880 | Image Quality Assessment · pooling=Minkowski · attention-map=γ2 · quality-estimate=Q2 | Joint Deep Image Restoration and Unsupervised Quality AssessmentSource quoteL101: \(Q_2\), from \(\gamma_2\) │ 0.880 │ 0.862 │ 0.658 |
| 2023 | QAIRN (Q2 from γ2) proposed | SRCC | 0.862 | Image Quality Assessment · pooling=Minkowski · attention-map=γ2 · quality-estimate=Q2 | Joint Deep Image Restoration and Unsupervised Quality AssessmentSource quoteL101: \(Q_2\), from \(\gamma_2\) │ 0.880 │ 0.862 │ 0.658 |
| 2023 | SaTQA (proposed) proposed | SROCC | 0.617 | Image Quality Assessment · split: test · evaluation=cross-dataset · training-dataset=LIVE | Transformer-Based No-Reference Image Quality Assessment via Supervised Contrastive LearningSource quoteL199: Proposed │ 0.791 │ 0.788 │ 0.831 │ 0.617 |
| 2023 | YOTO (HA + SDA cone) ablation | PLCC | 0.956 | Image Quality Assessment · split: test · HA=enabled · SDA=cone · assessment=no-reference | UNIQA: A Unified Framework for Both Full-Reference and No-Reference Image Quality AssessmentSource quoteL326: \CheckmarkBold │ \CheckmarkBold │ 0.956 │ 0.953 │ 0.970 │ 0.964 │ 0.965 │ 0.963 │ 0.979 │ 0.979 |
| 2023 | YOTO (HA + SDA cone) ablation | PLCC | 0.965 | Image Quality Assessment · split: test · HA=enabled · SDA=cone · assessment=full-reference | UNIQA: A Unified Framework for Both Full-Reference and No-Reference Image Quality AssessmentSource quoteL326: \CheckmarkBold │ \CheckmarkBold │ 0.956 │ 0.953 │ 0.970 │ 0.964 │ 0.965 │ 0.963 │ 0.979 │ 0.979 |
| 2023 | CIEDE2000 baseline non-standard slice | STRESS | 18.203 | Image Quality Assessment · compressed · subset=quantization noise, color quantization with dither, chromatic aberration | Learning a Deep Color Difference Metric for Photographic ImagesSource quoteL281: CIEDE2000~\cite{luo2001ciede2000} │ 18.203 │ 0.730 │ 0.751 |
| 2023 | CIEDE2000 baseline non-standard slice | PLCC | 0.730 | Image Quality Assessment · compressed · subset=quantization noise, color quantization with dither, chromatic aberration · protocol=four-parameter monotonic linearization | Learning a Deep Color Difference Metric for Photographic ImagesSource quoteL281: CIEDE2000~\cite{luo2001ciede2000} │ 18.203 │ 0.730 │ 0.751 |
| 2023 | CIEDE2000 baseline non-standard slice | SRCC | 0.751 | Image Quality Assessment · compressed · subset=quantization noise, color quantization with dither, chromatic aberration | Learning a Deep Color Difference Metric for Photographic ImagesSource quoteL281: CIEDE2000~\cite{luo2001ciede2000} │ 18.203 │ 0.730 │ 0.751 |
| 2023 | CONTRIQUE baseline | PLCC | 0.857 | Image Quality Assessment | Adaptive Feature Selection for No-Reference Image Quality Assessment by Mitigating Semantic Noise SensitivitySource quoteL421: CONTRIQUE │ 0.961 │ 0.960 │ 0.955 │ 0.942 │ 0.857 │ 0.843 │ 0.937 │ 0.934 │ 0.857 │ 0.845 │ 0.906 │ 0.894 │ 0.641 │ 0.580 │ {0.919} │ {0.914} |
| 2023 | CONTRIQUE baseline | SRCC | 0.843 | Image Quality Assessment | Adaptive Feature Selection for No-Reference Image Quality Assessment by Mitigating Semantic Noise SensitivitySource quoteL421: CONTRIQUE │ 0.961 │ 0.960 │ 0.955 │ 0.942 │ 0.857 │ 0.843 │ 0.937 │ 0.934 │ 0.857 │ 0.845 │ 0.906 │ 0.894 │ 0.641 │ 0.580 │ {0.919} │ {0.914} |
| 2023 | ResNet50 baseline | SRCC | 0.949 | Image Quality Assessment · split: test · protocol=full-reference | SAM-IQA: Can Segment Anything Boost Image Quality Assessment?Source quoteL185: ResNet50~\cite{he2016deep} │ 0.979 │ 0.982 │ 0.949 │ 0.958 |
| 2023 | ResNet50 baseline | PLCC | 0.958 | Image Quality Assessment · split: test · protocol=full-reference | SAM-IQA: Can Segment Anything Boost Image Quality Assessment?Source quoteL185: ResNet50~\cite{he2016deep} │ 0.979 │ 0.982 │ 0.949 │ 0.958 |
| 2022 | MSTRIQ proposed | PLCC | 0.895 | Image Quality Assessment | MSTRIQ: No Reference Image Quality Assessment Based on Swin Transformer with Multi-Stage FusionSource quoteL122: Ours │ 0.954 │ 0.946 │ 0.895 │ 0.882 |
| 2022 | MSTRIQ proposed | SRCC | 0.882 | Image Quality Assessment | MSTRIQ: No Reference Image Quality Assessment Based on Swin Transformer with Multi-Stage FusionSource quoteL122: Ours │ 0.954 │ 0.946 │ 0.895 │ 0.882 |
| 2022 | CVRKD-IQA NAR-student (NAR + KD) proposed | SRCC | 0.691 | Image Quality Assessment · runs=10 · reference=misaligned reference images · training-data=KADID-10K | Content-Variant Reference Image Quality Assessment via Knowledge DistillationSource quoteL152: NAR-student w/ KD │ \checkmark │ \checkmark │ 0.691 ± 0.003 │ 0.416 ± 0.004 |
| 2022 | DeepWSD w/P4 proposed | PLCC | 0.8697 | Image Quality Assessment · patch-size=4×4 | DeepWSD: Projecting Degradations in Perceptual Space to Wasserstein Distance in Deep Feature SpaceSource quoteL262: DeepWSD w/P4 │ 0.8697 │ 0.8741 │ 0.6932 │ 0.9609 │ 0.9624 │ 0.8378 │ 0.9503 │ 0.9652 │ 0.8297 │ 0.8434 │ 0.8883 │ 0.7076 |
| 2022 | NR-student baseline (no NAR, no KD) ablation | SRCC | 0.631 | Image Quality Assessment · NAR=disabled · training-data=KADID-10K · knowledge-distillation=disabled | Content-Variant Reference Image Quality Assessment via Knowledge DistillationSource quoteL150: NR-student baseline │ \texttimes │ \texttimes │ 0.631 ± 0.002 │ 0.317 ± 0.003 |
| 2022 | LPIPS (Alex-lin) baseline | Spearman's rank correlation coefficients (SRCC) | 0.744 | Image Quality Assessment · scaling=original image size | Evaluating the Stability of Deep Image Quality Assessment With Respect to Image ScalingSource quoteL161: TID2013 │ 0.590 │ 0.724 │ 0.807 │ 0.834 │ 0.841 │ 0.841 │ 0.833 │ 0.817 │ 0.796 │ 0.744 |
| 2022 | DISTS baseline | Spearman's rank correlation coefficients (SRCC) | 0.857 | Image Quality Assessment · scaling=bilinear down-scaling ×4/9 | Evaluating the Stability of Deep Image Quality Assessment With Respect to Image ScalingSource quoteL179: TID2013 │ 0.673 │ 0.803 │ 0.850 │ 0.857 │ 0.855 │ 0.844 │ 0.830 │ 0.807 │ 0.784 │ 0.708 |
| 2022 | DISTS baseline | Spearman's rank correlation coefficients (SRCC) | 0.830 | Image Quality Assessment · scaling=bilinear down-scaling ×6/9 | Evaluating the Stability of Deep Image Quality Assessment With Respect to Image ScalingSource quoteL179: TID2013 │ 0.673 │ 0.803 │ 0.850 │ 0.857 │ 0.855 │ 0.844 │ 0.830 │ 0.807 │ 0.784 │ 0.708 |
| 2021 | Proposed model (trained on PIPAL train phase) proposed | SRCC | 0.5371 | Image Quality Assessment · split: test · cross-dataset · train-data=PIPAL train phase | Deep Learning-Based Distortion Sensitivity Prediction for Full-Reference Image Quality AssessmentSource quoteL356: 0.5371 |
| 2021 | Proposed model (trained on PIPAL train phase) proposed | PLCC | 0.6264 | Image Quality Assessment · split: test · cross-dataset · train-data=PIPAL train phase | Deep Learning-Based Distortion Sensitivity Prediction for Full-Reference Image Quality AssessmentSource quoteL357: 0.6264 |
| 2021 | VTAMIQ proposed | SROCC | 0.874 | Image Quality Assessment | VTAMIQ: Transformers for Attention Modulated Image Quality AssessmentSource quoteL252: VTAMIQ (ours) │ 0.874 │ 0.899 │ 0.957 │ 0.907 │ 0.974 │ 0.897 |
| 2021 | RADN proposed | SROCC | 0.747 | Image Quality Assessment · split: test · training_data=PIPAL | Region-Adaptive Deformable Network for Image Quality AssessmentSource quoteL237: RADN │ 0.747 │ 0.796 │ 0.905 │ 0.878 |
| 2021 | FPR proposed | SRCC | 0.433 | Image Quality Assessment · split: test · cross-database · train_database=LIVE | No-Reference Image Quality Assessment by Hallucinating Pristine FeaturesSource quoteL339: Ours │ 0.620 │ 0.433 │ 0.895 │ 0.522 │ 0.884 │ 0.732 \bigstrut |
| 2021 | FPR proposed | SRCC | 0.522 | Image Quality Assessment · split: test · cross-database · train_database=CSIQ | No-Reference Image Quality Assessment by Hallucinating Pristine FeaturesSource quoteL339: Ours │ 0.620 │ 0.433 │ 0.895 │ 0.522 │ 0.884 │ 0.732 \bigstrut |
| 2021 | FPR proposed non-standard slice | SRCC | 0.953 | Image Quality Assessment · aggregation=average across ten settings · distortion_subset=additive Gaussian noise | No-Reference Image Quality Assessment by Hallucinating Pristine FeaturesSource quoteL254: Additive Gaussian noise │ 0.711 │ 0.766 │ 0.730 │ 0.692 │ 0.833 │ 0.813 │ 0.790 │ 0.953 \bigstrut[t] |
| 2021 | FPR proposed non-standard slice | SRCC | 0.923 | Image Quality Assessment · aggregation=average across ten settings · distortion_subset=JPEG compression | No-Reference Image Quality Assessment by Hallucinating Pristine FeaturesSource quoteL263: JPEG compression │ 0.764 │ 0.844 │ 0.813 │ 0.797 │ 0.891 │ 0.850 │ 0.894 │ 0.923 |
| 2021 | DOG-SSIMc | SROCC | 0.751 | Image Quality Assessment | VTAMIQ: Transformers for Attention Modulated Image Quality AssessmentSource quoteL248: DOG-SSIMc \cite{dog-ssim} │ 0.751 │ 0.948 |
| 2021 | MetaIQA+DCR | PRA | 85.59% | Image Quality Assessment | Disjoint Contrastive Regression Learning for Multi-Sourced AnnotationsSource quoteL212: \text{MetaIQA}+\text{DCR} │ 85.59 │ 0.825 │ 0.835 |
| 2021 | MetaIQA | PRA | 83.40% | Image Quality Assessment | Disjoint Contrastive Regression Learning for Multi-Sourced AnnotationsSource quoteL211: \text{MetaIQA} \cite{zhu2020metaiqa} │ 83.40 │ 0.807 │ 0.829 |
| 2021 | normal non-standard slice | Pearson correlation (PCC) | 0.49 | Image Quality Assessment · cross-database · subset=full database · training-dataset=LIVE | Curiously Effective Features for Image Quality PredictionSource quoteL162: normal │ 0.49 │ 0.44 │ 0.85 │ 0.8 │ 0.81 │ 0.8 │ 0.86 │ 0.87 │ 0.74 │ 0.76 │ 0.8 │ 0.8 |
| 2021 | CONTRIQUE | SROCC | 0.843 | Image Quality Assessment · split: test | Image Quality Assessment using Contrastive LearningSource quoteL206: \multirow{2}{*}{CONTRIQUE} │ \multirow{2}{*}{\shortstack[c]{Unsupervised pretraining and Linear Regression}} │ \multirow{2}{*}{0.960} │ \multirow{2}{*}{0.961} │ \multirow{2}{*}{0.942} │ \multirow{2}{*}{0.955} │ \multirow{2}{*}{0.843} │ \multirow{2}{*}{0.857} │ \multirow{2}{*}{0.934} │ \multirow{2}{*}{0.937} |
| 2021 | WaDIQaM baseline | SROCC | 0.698 | Image Quality Assessment · split: test | Region-Adaptive Deformable Network for Image Quality AssessmentSource quoteL236: WaDIQaM │ 0.698 │ 0.741 │ 0.883 │ 0.837 |
| 2020 | MetaIQA proposed | SROCC | 0.8539 | Image Quality Assessment · split: test | MetaIQA: Deep Meta-Learning for No-Reference Image Quality AssessmentSource quoteL215: Average │ 0.5322 │ 0.5950 │ 0.5701 │ 0.5465 │ 0.4725 │ 0.7073 │ 0.8539 |
| 2020 | QualNet (proposed) proposed | SROCC | 0.890 | Image Quality Assessment | No-Reference Image Quality Assessment via Feature Fusion and Multi-Task LearningSource quoteL398: QualNet (proposed) │ 0.980 │ 0.984 │ 0.907 │ 0.921 │ 0.890 │ 0.901 │ 0.961 │ 0.965 │ 0.960 │ 0.952 │ 0.938 │ 0.943\tabularnewline |
| 2020 | LPIPS-Alex* | SRCC | 0.7604 | Image Quality Assessment | Image Quality Assessment for Perceptual Image Restoration: A New Dataset, Benchmark and MetricSource quoteL744: 0.7604 │ 0.5800 |
| 2020 | SWDN* | SRCC | 0.8187 | Image Quality Assessment | Image Quality Assessment for Perceptual Image Restoration: A New Dataset, Benchmark and MetricSource quoteL752: 0.8187 │ 0.6335 |
| 2020 | WaDIQaM-NR | SROCC | 0.7073 | Image Quality Assessment · split: test | MetaIQA: Deep Meta-Learning for No-Reference Image Quality AssessmentSource quoteL215: Average │ 0.5322 │ 0.5950 │ 0.5701 │ 0.5465 │ 0.4725 │ 0.7073 │ 0.8539 |
| 2019 | MT-RankIQA proposed non-standard slice | LCC | 0.827 | Image Quality Assessment · subset=entire database · training=multi-task | Exploiting Unlabeled Data in CNNs by Self-Supervised Learning to Rank.Source quoteL1115: MT-RankIQA (Ours) │ 0.827 │ 0.806 |
| 2019 | RRLRIQA proposed non-standard slice | SROCC | 0.806 | Image Quality Assessment · split: test · fine-tuned · repeats=20; median · split-protocol=80/20 grouped by reference image · training-target=objective-score rewards, not MOS | No-Reference Image Quality Assessment with Reinforcement Recursive List-Wise RankingSource quoteL371: 0.806 |
| 2019 | DB-CNN proposed | SRCC | 0.816 | Image Quality Assessment | Blind Image Quality Assessment Using A Deep Bilinear Convolutional Neural NetworkSource quoteL330: DB-CNN │ {\bf 0.968} │ {\bf0.946} │ {\bf 0.816} │ {\bf 0.851} |
| 2019 | DA-IQA proposed | SROCC | 0.828 | Image Quality Assessment · split: test | Domain-Aware No-Reference Image Quality AssessmentSource quoteL313: DA-IQA │ 0.477 │ 0.695 │ 0.438 │ 0.674 │ 0.709 │ 0.852 │ 0.713 │ 0.897 │ 0.808 │ 0.774 │ 0.868 │ 0.828 |
| 2019 | CD²-B proposed | PLCC | 0.8962 | Image Quality Assessment · split: val · evaluation=DMOS prediction · cross-validation=5-fold | CD2 : Combined Distances of Contrast Distributions for the Assessment of Perceptual Quality of Image ProcessingSource quoteL320: PLCC │ 0.6125 │ 0.8962 │ 0.5851 │ 0.8180 │ 0.4784 │ 0.6868 │ 0.8767 |
| 2019 | Proposed BIQA method (Ours, All databases) proposed | SRCC | 0.855 | Image Quality Assessment · split: test · resolution=original image size · training-data=all six IQA databases | Learning To Blindly Assess Image Quality In The Laboratory And WildSource quoteL110: Ours (All databases) │ {\bf 0.961} │ {\bf 0.907} │ {\bf 0.855} │ {\bf 0.863} │ {\bf 0.851} │ {\bf 0.894} |
| 2019 | Res-50 fine-tuned baseline baseline non-standard slice | SROCC | 0.712 | Image Quality Assessment · split: test · fine-tuned · repeats=20; median · backbone=ResNet-50 · split-protocol=80/20 grouped by reference image · training-target=MOS | No-Reference Image Quality Assessment with Reinforcement Recursive List-Wise RankingSource quoteL364: 0.712 |
| 2019 | RankIQA baseline | SROCC | 0.780 | Image Quality Assessment · split: test | Domain-Aware No-Reference Image Quality AssessmentSource quoteL312: RankIQA │ 0.597 │ 0.622 │ 0.268 │ 0.613 │ 0.662 │ 0.619 │ 0.644 │ 0.800 │ 0.779 │ 0.629 │ 0.859 │ 0.780 |
| 2019 | FSIM baseline | PLCC | 0.8767 | Image Quality Assessment · split: val · evaluation=DMOS prediction · cross-validation=5-fold | CD2 : Combined Distances of Contrast Distributions for the Assessment of Perceptual Quality of Image ProcessingSource quoteL320: PLCC │ 0.6125 │ 0.8962 │ 0.5851 │ 0.8180 │ 0.4784 │ 0.6868 │ 0.8767 |
| 2018 | MS-UNIQUE proposed | Pearson Correlation Coefficient | 0.884 | Image Quality Assessment · split: val · evaluation-type=full-reference | MS-UNIQUE: Multi-model and Sharpness-weighted Unsupervised Image Quality EstimationSource quoteL135: \multirow{1}{*}{{\bf TID13}} │ 0.705 │ 0.850 │ 0.827 │ 0.789 │ 0.832 │ 0.227 │ 0.831 │ 0.866 │ 0.832 │ 0.854 │ 0.870 │ \bf 0.884 |
| 2018 | MS-UNIQUE proposed | Spearman Correlation Coefficient | 0.870 | Image Quality Assessment · split: val · evaluation-type=full-reference | MS-UNIQUE: Multi-model and Sharpness-weighted Unsupervised Image Quality EstimationSource quoteL141: \multirow{1}{*}{{\bf TID13}} │ 0.700 │ 0.847 │ 0.817 │ 0.741 │ 0.785 │ 0.562 │ 0.777 │ 0.807 │ 0.851 │ 0.853 │ 0.860 │ \bf 0.870 |
| 2018 | BPSQM, MD PM (MDSI gradient and chromaticity similarity-map labels) proposed | SRCC | 0.863 | Image Quality Assessment · label-variant=MDSI gradient and chromaticity similarity maps | Blind Predicting Similar Quality Map for Image Quality AssessmentSource quoteL170: 0.863 |
| 2018 | BPSQM, MD PM (MDSI gradient and chromaticity similarity-map labels) proposed | PLCC | 0.879 | Image Quality Assessment · label-variant=MDSI gradient and chromaticity similarity maps | Blind Predicting Similar Quality Map for Image Quality AssessmentSource quoteL176: 0.879 |
| 2018 | BPSQM, Fg PM (FSIM gradient-magnitude map labels) proposed | SRCC | 0.828 | Image Quality Assessment · label-variant=FSIM gradient-magnitude maps | Blind Predicting Similar Quality Map for Image Quality AssessmentSource quoteL168: 0.828 |
| 2018 | BPSQM, Fg PM (FSIM gradient-magnitude map labels) proposed | PLCC | 0.856 | Image Quality Assessment · label-variant=FSIM gradient-magnitude maps | Blind Predicting Similar Quality Map for Image Quality AssessmentSource quoteL174: 0.856 |
| 2018 | CSV proposed non-standard slice | Spearman (SCC) | 0.845 | Image Quality Assessment · subset=full | CSV: Image Quality Assessment Based on Color, Structure, and Visual SystemSource quoteL452: CSV │ 0.849 │ 0.880 │ 0.924 │ 0.812 │ 0.898 │ 0.888 │ 0.845 |
| 2018 | BPSQM, No LB (end-to-end training without FR-IQA map labels) ablation | SRCC | 0.736 | Image Quality Assessment · ablation=without FR-IQA similarity-map labels | Blind Predicting Similar Quality Map for Image Quality AssessmentSource quoteL166: 0.736 |
| 2018 | BPSQM, No LB (end-to-end training without FR-IQA map labels) ablation | PLCC | 0.779 | Image Quality Assessment · ablation=without FR-IQA similarity-map labels | Blind Predicting Similar Quality Map for Image Quality AssessmentSource quoteL172: 0.779 |
| 2018 | ITU-T Rec. P.1401 statistical significance test, aggregated as DB Sum | DB Sum of statistically different Pearson correlation comparisons | 116 comparisons | Image Quality Assessment | A comparative study of quality and content-based spatial pooling strategies in image quality assessmentSource quoteL204: Statistical significance tests show that none of the pooling strategies is different than the others in all databases and metric types in terms of Pearson correlation. Database selection is important in comparing the pooling strategies. The sum of the individual columns (Col. Sum) corresponds to the total statistical difference in a specific database using a specific attribute. For each quality attribute, TID leads to the highest statistical significance total since it has a wide range of distortion types where different pooling strategies can stand out. When the statistical significance totals are summed up for each database (DB Sum), we can see that multiply distorted LIVE database (M-Live) has the least statistically different comparisons (66) and TID has the most (116). |
| 2017 | NIMA(VGG16) proposed non-standard slice | LCC (mean score) | 0.941 | Image Quality Assessment · split: test | NIMA: Neural Image AssessmentSource quoteL156: NIMA(VGG16) │ 0.941 │ 0.944 │ 0.538 │ 0.557 │ 0.054 |
| 2017 | NIMA(VGG16) proposed non-standard slice | SRCC (mean score) | 0.944 | Image Quality Assessment · split: test | NIMA: Neural Image AssessmentSource quoteL156: NIMA(VGG16) │ 0.941 │ 0.944 │ 0.538 │ 0.557 │ 0.054 |
| 2017 | RankIQA (VGG-16) proposed | SROCC | 0.623 | Image Quality Assessment · split: test · fine-tuned · runs=10 · backbone=VGG-16 · training=generated ranking data · distortions=all · split_protocol=80/20 by reference images | RankIQA: Learning from Rankings for No-Reference Image Quality AssessmentSource quoteL612: RankIQA │ 0.463 │ 0.693 │ 0.321 │ 0.657 │ 0.622 │ 0.845 │ 0.609 │ 0.891 │ 0.788 │ 0.727 │ \multicolumn{1}{c|}{0.768} │ \multicolumn{2}{c}{0.623} |
| 2017 | Bianco et al. baseline non-standard slice | LCC (mean score) | 0.96 | Image Quality Assessment | NIMA: Neural Image AssessmentSource quoteL154: Bianco et al. \cite{bianco2016use} │ 0.96 │ 0.96 │ -- │ -- │ -- \hdashline |
| 2017 | Baseline (VGG-16 fine-tuned directly on TID2013) baseline | SROCC | 0.612 | Image Quality Assessment · split: test · fine-tuned · runs=10 · distortions=all · split_protocol=80/20 by reference images | RankIQA: Learning from Rankings for No-Reference Image Quality AssessmentSource quoteL611: Baseline │ 0.187 │ 0.308 │ 0.062 │ 0.546 │ 0.383 │ 0.500 │ 0.420 │ 0.700 │ 0.611 │ 0.573 │ \multicolumn{1}{c|}{0.742} │ \multicolumn{2}{c}{0.612} |
| 2016 | WaDIQaM-FR proposed | LCC | 0.946 | Image Quality Assessment · split: test · evaluation=all distortion types; 10 random splits · reference-type=full-reference · patches-per-image=32 | Deep Neural Networks for No-Reference and Full-Reference Image Quality AssessmentSource quoteL670: \bf{0.946} │ \bf{0.940} |
| 2016 | WaDIQaM-FR proposed | SROCC | 0.940 | Image Quality Assessment · split: test · evaluation=all distortion types; 10 random splits · reference-type=full-reference · patches-per-image=32 | Deep Neural Networks for No-Reference and Full-Reference Image Quality AssessmentSource quoteL670: \bf{0.946} │ \bf{0.940} |
| 2016 | DIQaM-NR proposed | LCC | 0.855 | Image Quality Assessment · split: test · evaluation=all distortion types; 10 random splits · reference-type=no-reference | Deep Neural Networks for No-Reference and Full-Reference Image Quality AssessmentSource quoteL682: DIQaM-NR (proposed) │ \bf{0.972} │ 0.960 │ \bf{0.855} │ \bf{0.835} |
| 2016 | HaarPSI proposed non-standard slice | Spearman rank order correlation with human mean opinion scores | 0.9704 | Image Quality Assessment · subset=jpg2k · image-type=color · preprocessing=2×2 mean filter and dyadic subsampling | A Haar Wavelet-Based Perceptual Similarity Index for Image Quality AssessmentSource quoteL382: jpg2k │ 0.8840 │ 0.9516 │ 0.9468 │ 0.9504 │ 0.9602 │ 0.9511 │ 0.9672 │ 0.9589 │ 0.9706 │ 0.9704 |
| 2016 | HaarPSI proposed | Pearson correlation with human mean opinion scores | 0.8904 | Image Quality Assessment · image-type=color | A Haar Wavelet-Based Perceptual Similarity Index for Image Quality AssessmentSource quoteL500: TID2013 │ 0.4785 │ 0.7335 │ 0.7596 │ 0.7773 │ 0.7966 │ 0.8074 │ 0.7984 │ 0.8322 │ 0.8373 │ 0.8904 |
| 2015 | SOS-H-rNSE proposed | PCC | 0.937 | Image Quality Assessment · distortions=JP2K, JPEG, WN, GB | Learn to Evaluate Image Perceptual Quality Blindly from Statistics of Self-similaritySource quoteL177: From TABLE~\ref{Table_2}, we can observe that both SOS-MD and SOS-H show good performance on the three databases in terms of PCC and SRC. The best results on all the three databases are achieved by the method SOS-H-rNSE, with PCC values 0.946, 0.933, and 0.937 on the three databases, respectively. For every single distortion type, it also demonstrates PCC and SRC values consistently higher than 0.9. Note that due to the scale difference of subjective scores on the three databases, the resulting RMSE values range differently. |
| 2015 | SOS-H-rNSE proposed | SRC | 0.913 | Image Quality Assessment · split: test · distortions=JP2K, JPEG, WN, GB · train-dataset=LIVE | Learn to Evaluate Image Perceptual Quality Blindly from Statistics of Self-similaritySource quoteL232: TID2013 │ 0.860 │ 0.895 │ 0.891 │ 0.923 │ 0.897 │ 0.913 |