TID2013 · Image Quality Assessment

51 papers · 100 extracted observations · image quality assessment · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Image Quality Assessment: proposed/measured results on test (including papers where test split is standard/implicit).

0.60.70.91.0201820222026BPSQM, Fg PM (FSIM gradient-magnitude map labels): 0.828 (2018)BPSQM, MD PM (MDSI gradient and chromaticity similarity-map labels): 0.863 (2018)DB-CNN: 0.816 (2019)Proposed BIQA method (Ours, All databases): 0.855 (2020)LPIPS-Alex*: 0.7604 (2020)SWDN*: 0.8187 (2020)CVRKD-IQA NAR-student (NAR + KD): 0.691 (2022)MSTRIQ: 0.882 (2022)QAIRN (Q2 from γ2): 0.862 (2023)UniQA: 0.916 (2024)DiffV^2IQA: 0.652 (2025)HarmonyIQA (NR): 0.901 (2025)Gamma (MoAE-equipped; task-specific training): 0.944 (2025)Magnitude-Aware CLIP (MA-CLIP): 0.599 (2025)MQAF-R: 0.847 (2026)Causal Disentanglement, Ours w/ (f): 0.899 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2019CD²-B proposedPLCC0.8962Image Quality Assessment · split: val · evaluation=DMOS prediction · cross-validation=5-foldCD2 : Combined Distances of Contrast Distributions for the Assessment of Perceptual Quality of Image Processing
Source quote
L320: PLCC │ 0.6125 │ 0.8962 │ 0.5851 │ 0.8180 │ 0.4784 │ 0.6868 │ 0.8767
2019FSIM baselinePLCC0.8767Image Quality Assessment · split: val · evaluation=DMOS prediction · cross-validation=5-foldCD2 : Combined Distances of Contrast Distributions for the Assessment of Perceptual Quality of Image Processing
Source quote
L320: PLCC │ 0.6125 │ 0.8962 │ 0.5851 │ 0.8180 │ 0.4784 │ 0.6868 │ 0.8767
2018MS-UNIQUE proposedPearson Correlation Coefficient0.884Image Quality Assessment · split: val · evaluation-type=full-referenceMS-UNIQUE: Multi-model and Sharpness-weighted Unsupervised Image Quality Estimation
Source quote
L135: \multirow{1}{*}{{\bf TID13}} │ 0.705 │ 0.850 │ 0.827 │ 0.789 │ 0.832 │ 0.227 │ 0.831 │ 0.866 │ 0.832 │ 0.854 │ 0.870 │ \bf 0.884
2018MS-UNIQUE proposedSpearman Correlation Coefficient0.870Image Quality Assessment · split: val · evaluation-type=full-referenceMS-UNIQUE: Multi-model and Sharpness-weighted Unsupervised Image Quality Estimation
Source quote
L141: \multirow{1}{*}{{\bf TID13}} │ 0.700 │ 0.847 │ 0.817 │ 0.741 │ 0.785 │ 0.562 │ 0.777 │ 0.807 │ 0.851 │ 0.853 │ 0.860 │ \bf 0.870