TID2013 · Image Quality Assessment

51 papers · 100 extracted observations · image quality assessment · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Image Quality Assessment: proposed/measured results on test (including papers where test split is standard/implicit).

0.60.70.91.0201820222026BPSQM, Fg PM (FSIM gradient-magnitude map labels): 0.828 (2018)BPSQM, MD PM (MDSI gradient and chromaticity similarity-map labels): 0.863 (2018)DB-CNN: 0.816 (2019)Proposed BIQA method (Ours, All databases): 0.855 (2020)LPIPS-Alex*: 0.7604 (2020)SWDN*: 0.8187 (2020)CVRKD-IQA NAR-student (NAR + KD): 0.691 (2022)MSTRIQ: 0.882 (2022)QAIRN (Q2 from γ2): 0.862 (2023)UniQA: 0.916 (2024)DiffV^2IQA: 0.652 (2025)HarmonyIQA (NR): 0.901 (2025)Gamma (MoAE-equipped; task-specific training): 0.944 (2025)Magnitude-Aware CLIP (MA-CLIP): 0.599 (2025)MQAF-R: 0.847 (2026)Causal Disentanglement, Ours w/ (f): 0.899 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 27 of 27 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Causal Disentanglement, Ours w/ (f) proposedPLCC0.916Image Quality Assessment · fine-tuned · training=supervised-mosCausal Disentanglement-Inspired Degradation Representation Learning for Full-Reference Image Quality Assessment
Source quote
L366: Ours w/ (f) │ \textcolor{blue}{0.968} │ \textcolor{red}{0.966} │ \textcolor{red}{0.966} │ 0.954 │ \textcolor{red}{0.916} │ \textcolor{red}{0.899} │ \textcolor{red}{0.902} │ 0.897 │ \textcolor{blue}{0.727 (f)} │ \textcolor{blue}{0.713 (f)}
2025Life-IQA proposedPLCC0.578Image Quality Assessment · split: testLife-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature Decoupling
Source quote
L239: Life-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}}
2025LGDM-ψSDv1.5 proposedPLCC0.921Image Quality Assessment · params=5B · steps=10 DDIM · backbone=Stable Diffusion v1.5 · distortion=syntheticLGDM: Latent Guidance in Diffusion Models for Perceptual Evaluations
Source quote
L649: 2019) datasets, with PLCC and SRCC scores of 0.921/0.883 and 0.961/0.958, respectively, underscores the value of utilizing diffusion hyperfeatures. Additional results are provided in Appendix D.
2025LGDM-\psi_{\text{SDv1.5}}PLCC0.921Image Quality AssessmentLatent Guidance in Diffusion Models for Perceptual Evaluations
Source quote
L292: Table~\ref{tab:synthetic_scores} reports the PLCC and SRCC scores of LGDM and existing NR-IQA methods on four synthetic datasets: LIVE \cite{sheikh2006statistical}, CSIQ \cite{larson2010most}, TID2013 \cite{ponomarenko2013color}, and KADID \cite{lin2019kadid}. The results demonstrate that our proposed approach outperforms other methods across almost all datasets. Similar to the performance on authentic distortion dataset in Table~\ref{tab:authentic_scores}, LGDM-\psi-SDv1.5 achieves the best performance across all synthetic datasets, indicating a strong alignment with human perceptual judgments. The results also suggest that perceptual guidance using \psi-Re-IQA and \psi-SDv1.5 consistently enhances the model's generalization capabilities. The superior performance of LGDM-\psi-SDv1.5 on the TID2013 \cite{ponomarenko2013color}and KADID \cite{lin2019kadid} datasets, with PLCC and SRCC scores of 0.921/0.883 and 0.961/0.958, respectively, underscores the value of utilizing diffusion hyperfeatures. Additional results are provided in Appendix~\ref{appendix:results}.
2024UniQA proposedPLCC0.931Image Quality Assessment · fine-tuned · inference-patches=10UniQA: Unified Vision-Language Pre-training for Image Quality and Aesthetic Assessment
Source quote
L689: Ours │ 0.916 │ 0.931 │ 0.963 │ 0.973 │ 0.940 │ 0.943 │ 0.890 │ 0.905 │ 0.933 │ 0.941 │ 0.924 │ 0.928
2024PromptIQA (MDT) proposedPLCC0.5992Image Quality Assessment · split: test · few-shot · label-generation=SSIMPromptIQA: Boosting the Performance and Generalization for No-Reference Image Quality Assessment via Prompts
Source quote
L197: \multicolumn{1}{c|}{\multirow{-2}{*}{PromptIQA}} │ MDT │ Few-shot │ 0.5992 │ 0.8802 │ 0.8064 │ 0.5717 │ 0.7196 │ 0.7615
2024PromptIQA (MDT) proposedPLCC0.8802Image Quality Assessment · split: test · few-shot · label-generation=FSIMPromptIQA: Boosting the Performance and Generalization for No-Reference Image Quality Assessment via Prompts
Source quote
L197: \multicolumn{1}{c|}{\multirow{-2}{*}{PromptIQA}} │ MDT │ Few-shot │ 0.5992 │ 0.8802 │ 0.8064 │ 0.5717 │ 0.7196 │ 0.7615
2024PromptIQA (MDT) proposedPLCC0.8064Image Quality Assessment · split: test · few-shot · label-generation=LPIPSPromptIQA: Boosting the Performance and Generalization for No-Reference Image Quality Assessment via Prompts
Source quote
L197: \multicolumn{1}{c|}{\multirow{-2}{*}{PromptIQA}} │ MDT │ Few-shot │ 0.5992 │ 0.8802 │ 0.8064 │ 0.5717 │ 0.7196 │ 0.7615
2024AMqF proposedPLCC0.830Image Quality Assessment · cross-database · adaptation=none · training-dataset=KADID-10kImage Quality Assessment: Exploring Regional Heterogeneity via Response of Adaptive Multiple Quality Factors in Dictionary Space
Source quote
L117: AMqF (ours) │ \bf 0.907 │ \bf0.926 │ \bf 0.866 │ \bf0.862 │ \bf 0.830 │ \bf 0.815
2024Our-VGG, φ = φγ (causal-effect weights) ablationPLCC0.909Image Quality Assessment · backbone=VGG · component=causal-effect weightsImage Quality Assessment: Investigating Causal Perceptual Effects with Abductive Counterfactual Inference
Source quote
L303: 0.929 │ 0.932 │ 0.949 │ 0.952 │ 0.909 │ 0.884
2024Our-VGG, φ = φη (residual component excluding causal effect) ablationPLCC0.786Image Quality Assessment · backbone=VGG · component=residual component excluding causal effectImage Quality Assessment: Investigating Causal Perceptual Effects with Abductive Counterfactual Inference
Source quote
L305: 0.843 │ 0.866 │ 0.803 │ 0.831 │ 0.786 │ 0.789
2024LML-IQAPLCC0.942Image Quality Assessment · split: testLocal Manifold Learning for No-Reference Image Quality Assessment
Source quote
L9: Image Quality Assessment (IQA) methods typically overlook local manifold structures, leading to compromised discriminative capabilities in perceptual quality evaluation. To address this limitation, we present LML-IQA, an innovative no-reference IQA (NR-IQA) approach that leverages a combination of local manifold learning and contrastive learning. Our approach first extracts multiple patches from each image and identifies the most visually salient region. This salient patch serves as a positive sample for contrastive learning, while other patches from the same image are treated as intra-class negatives to preserve local distinctiveness. Patches from different images also act as inter-class negatives to enhance feature separation. Additionally, we introduce a mutual learning strategy to improve the model’s ability to recognize and prioritize visually important regions. Comprehensive experiments across eight benchmark datasets demonstrate significant performance gains over state-of-the-art methods, achieving a PLCC of 0.942 on TID2013 (compared to 0.908) and 0.977 on CSIQ (compared to 0.965).
2024DEIQTPLCC0.908Image Quality AssessmentLocal Manifold Learning for No-Reference Image Quality Assessment
Source quote
L9: Image Quality Assessment (IQA) methods typically overlook local manifold structures, leading to compromised discriminative capabilities in perceptual quality evaluation. To address this limitation, we present LML-IQA, an innovative no-reference IQA (NR-IQA) approach that leverages a combination of local manifold learning and contrastive learning. Our approach first extracts multiple patches from each image and identifies the most visually salient region. This salient patch serves as a positive sample for contrastive learning, while other patches from the same image are treated as intra-class negatives to preserve local distinctiveness. Patches from different images also act as inter-class negatives to enhance feature separation. Additionally, we introduce a mutual learning strategy to improve the model’s ability to recognize and prioritize visually important regions. Comprehensive experiments across eight benchmark datasets demonstrate significant performance gains over state-of-the-art methods, achieving a PLCC of 0.942 on TID2013 (compared to 0.908) and 0.977 on CSIQ (compared to 0.965).
2023CD-Flow proposed non-standard slicePLCC0.837Image Quality Assessment · compressed · subset=quantization noise, color quantization with dither, chromatic aberration · protocol=four-parameter monotonic linearizationLearning a Deep Color Difference Metric for Photographic Images
Source quote
L287: CD-Flow │ 14.110 │ 0.837 │ 0.832
2023YOTO (HA + SDA cone) ablationPLCC0.956Image Quality Assessment · split: test · HA=enabled · SDA=cone · assessment=no-referenceUNIQA: A Unified Framework for Both Full-Reference and No-Reference Image Quality Assessment
Source quote
L326: \CheckmarkBold │ \CheckmarkBold │ 0.956 │ 0.953 │ 0.970 │ 0.964 │ 0.965 │ 0.963 │ 0.979 │ 0.979
2023YOTO (HA + SDA cone) ablationPLCC0.965Image Quality Assessment · split: test · HA=enabled · SDA=cone · assessment=full-referenceUNIQA: A Unified Framework for Both Full-Reference and No-Reference Image Quality Assessment
Source quote
L326: \CheckmarkBold │ \CheckmarkBold │ 0.956 │ 0.953 │ 0.970 │ 0.964 │ 0.965 │ 0.963 │ 0.979 │ 0.979
2023CIEDE2000 baseline non-standard slicePLCC0.730Image Quality Assessment · compressed · subset=quantization noise, color quantization with dither, chromatic aberration · protocol=four-parameter monotonic linearizationLearning a Deep Color Difference Metric for Photographic Images
Source quote
L281: CIEDE2000~\cite{luo2001ciede2000} │ 18.203 │ 0.730 │ 0.751
2023CONTRIQUE baselinePLCC0.857Image Quality AssessmentAdaptive Feature Selection for No-Reference Image Quality Assessment by Mitigating Semantic Noise Sensitivity
Source quote
L421: CONTRIQUE │ 0.961 │ 0.960 │ 0.955 │ 0.942 │ 0.857 │ 0.843 │ 0.937 │ 0.934 │ 0.857 │ 0.845 │ 0.906 │ 0.894 │ 0.641 │ 0.580 │ {0.919} │ {0.914}
2023ResNet50 baselinePLCC0.958Image Quality Assessment · split: test · protocol=full-referenceSAM-IQA: Can Segment Anything Boost Image Quality Assessment?
Source quote
L185: ResNet50~\cite{he2016deep} │ 0.979 │ 0.982 │ 0.949 │ 0.958
2022MSTRIQ proposedPLCC0.895Image Quality AssessmentMSTRIQ: No Reference Image Quality Assessment Based on Swin Transformer with Multi-Stage Fusion
Source quote
L122: Ours │ 0.954 │ 0.946 │ 0.895 │ 0.882
2022DeepWSD w/P4 proposedPLCC0.8697Image Quality Assessment · patch-size=4×4DeepWSD: Projecting Degradations in Perceptual Space to Wasserstein Distance in Deep Feature Space
Source quote
L262: DeepWSD w/P4 │ 0.8697 │ 0.8741 │ 0.6932 │ 0.9609 │ 0.9624 │ 0.8378 │ 0.9503 │ 0.9652 │ 0.8297 │ 0.8434 │ 0.8883 │ 0.7076
2021Proposed model (trained on PIPAL train phase) proposedPLCC0.6264Image Quality Assessment · split: test · cross-dataset · train-data=PIPAL train phaseDeep Learning-Based Distortion Sensitivity Prediction for Full-Reference Image Quality Assessment
Source quote
L357: 0.6264
2019CD²-B proposedPLCC0.8962Image Quality Assessment · split: val · evaluation=DMOS prediction · cross-validation=5-foldCD2 : Combined Distances of Contrast Distributions for the Assessment of Perceptual Quality of Image Processing
Source quote
L320: PLCC │ 0.6125 │ 0.8962 │ 0.5851 │ 0.8180 │ 0.4784 │ 0.6868 │ 0.8767
2019FSIM baselinePLCC0.8767Image Quality Assessment · split: val · evaluation=DMOS prediction · cross-validation=5-foldCD2 : Combined Distances of Contrast Distributions for the Assessment of Perceptual Quality of Image Processing
Source quote
L320: PLCC │ 0.6125 │ 0.8962 │ 0.5851 │ 0.8180 │ 0.4784 │ 0.6868 │ 0.8767
2018BPSQM, MD PM (MDSI gradient and chromaticity similarity-map labels) proposedPLCC0.879Image Quality Assessment · label-variant=MDSI gradient and chromaticity similarity mapsBlind Predicting Similar Quality Map for Image Quality Assessment
Source quote
L176: 0.879
2018BPSQM, Fg PM (FSIM gradient-magnitude map labels) proposedPLCC0.856Image Quality Assessment · label-variant=FSIM gradient-magnitude mapsBlind Predicting Similar Quality Map for Image Quality Assessment
Source quote
L174: 0.856
2018BPSQM, No LB (end-to-end training without FR-IQA map labels) ablationPLCC0.779Image Quality Assessment · ablation=without FR-IQA similarity-map labelsBlind Predicting Similar Quality Map for Image Quality Assessment
Source quote
L172: 0.779