PROMISE12
19 papers · 42 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on val (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | Volumetric ConvNet (long-short connections) SOTA frontier (+3 variants) | 86.93% | 2017-01-01 | validation=10-fold-cross-validation · Standard 10-fold cross-validation on the 50 training images. | Volumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR ImagesSource quote86.93 |
| 2 | DDSP ConNet (DDSP block; DSC loss) (+2 variants) | 86.66% | 2018-01-01 | loss=DSC · Loss/block ablation; the basic model retained residual long connection and multi-supe… | Volumetric Densely Dilated Spatial Pooling ConNets for Prostate SegmentationSource quote86.66% |
Metricdsc (11)dice (10)dice coefficient (7)mean vdsc (4)reported segmentation score (2)mean 3d dice (2)
Showing 42 of 42 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | AutoMedImg-Claude-4.5-Opus proposed | Dice | 0.9517 | split: test · supervised · trials=Pass@3 · modality=MRI · dimension=2D | Towards Fully Automated Medical Imaging Code Generation via Validation-based Context EngineeringSource quoteL376: \texttt{AutoMedImg-Claude-4.5-Opus} │ 0 │ 0.8185 │ 0 │ 0.9041 │ 0 │ 0.7696 │ 0 │ 0.8789 │ 0 │ 0.9517 │ 0 │ 0.9938 |
| 2025 | H-SAMora proposed | Mean Dice | 90.14 | few-shot · training-data=7.5% | SAMora: Enhancing SAM through Hierarchical Self-Supervised Pre-Training for Medical ImagesSource quoteL765: H-SAMora (Ours) │ 84.34 │ 92.46 │ 90.14 |
| 2025 | BCP baseline | Dice↑ | 79.68 | semi-supervised · labeled-data=10% · unlabeled-data=90% | Bidirectional Uncertainty-Aware Region Learning for Semi-Supervised Medical Image SegmentationSource quoteL241: BCP │ 79.68 │ 7.84 |
| 2025 | BCP baseline | Dice↑ | 79.81 | semi-supervised · labeled-data=20% · unlabeled-data=80% | Bidirectional Uncertainty-Aware Region Learning for Semi-Supervised Medical Image SegmentationSource quoteL247: BCP │ 79.81 │ 2.9 |
| 2025 | SAM 3 T baseline | Dice | 0.6110 | Reported in the 3D medical-image dataset table; SAM 3 T setting as labeled. No further … | MedSAM3: Delving into Segment Anything with Medical ConceptsSource quoteL262: 0.6110 {\textcolor{red!70!black}{\downarrow\,0.2901}} |
| 2025 | nn-Unet baseline | Dice | 0.9011 | Reported in the 3D medical-image dataset table; no further split details are stated in … | MedSAM3: Delving into Segment Anything with Medical ConceptsSource quoteL256: nn-Unet │ 0.8311 │ 0.7714 │ 0.9011 │ 0.7718 |
| 2024 | SemSim proposed | DSC | 0.758 | split: test · semi-supervised · input=2D slices from 3D scans · labeled-data=3% | SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image SegmentationSource quoteL417: SemSim │ {\color[HTML]{FF0000}0.758} │ {\color[HTML]{FF0000}1.6} │ {\color[HTML]{FF0000}0.784} │ {\color[HTML]{FF0000}1.3} |
| 2024 | SemSim proposed | DSC | 0.784 | split: test · semi-supervised · input=2D slices from 3D scans · labeled-data=7% | SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image SegmentationSource quoteL417: SemSim │ {\color[HTML]{FF0000}0.758} │ {\color[HTML]{FF0000}1.6} │ {\color[HTML]{FF0000}0.784} │ {\color[HTML]{FF0000}1.3} |
| 2024 | CSA-Net proposed | DSC | 0.921 | Binary prostate capsule segmentation. | A Flexible 2.5D Medical Image Segmentation Approach with In-Slice and Cross-Slice AttentionSource quoteL190: CSA-Net │ 0.921 │ 1.06 |
| 2024 | 2.5D TransUNet baseline | DSC | 0.910 | Binary prostate capsule segmentation. | A Flexible 2.5D Medical Image Segmentation Approach with In-Slice and Cross-Slice AttentionSource quoteL188: 2.5D TransUNet │ 0.910 │ 1.14 |
| 2023 | Proposed method (TSD + MSLC; table label “Ours”) proposed | reported segmentation score | 86.90 | test-time-adaptation · source_dataset=MSD05 | Feature Alignment and Uniformity for Test Time AdaptationSource quoteL304: Ours │ 86.90 │ 86.78 │ 84.62 │ 80.89 |
| 2023 | SCP-Net proposed | DSC | 77.06 | semi-supervised · labeled-scans=7 · unlabeled-scans=28 | Self-aware and Cross-sample Prototypical Learning for Semi-supervised Medical Image SegmentationSource quoteL224: SCP-Net │ 7 │ 28 │ 77.06 │ 3.52 |
| 2023 | ERM baseline | reported segmentation score | 83.00 | test-time-adaptation · source_dataset=MSD05 | Feature Alignment and Uniformity for Test Time AdaptationSource quoteL302: ERM \cite{DBLP:books/daglib/0097035} │ 83.00 │ 82.34 │ 81.05 │ 68.17 |
| 2023 | U-Net (limited supervised) baseline | DSC | 60.88 | supervised · labeled-scans=7 · unlabeled-scans=0 | Self-aware and Cross-sample Prototypical Learning for Semi-supervised Medical Image SegmentationSource quoteL223: U-Net │ 7 │ 0 │ 60.88 │ 13.87 |
| 2022 | C-CAM proposed | DSC | 77.26% | split: test · weakly-supervised · supervision=image-level | C-CAM: Causal CAM for Weakly Supervised Semantic Segmentation on Medical ImageSource quoteL20: Recently, many excellent weakly supervised semantic segmentation (WSSS) works are proposed based on class activation mapping (CAM). However, there are few works that consider the characteristics of medical images. In this paper, we find that there are mainly two challenges of medical images in WSSS: i) the boundary of object foreground and background is not clear; ii) the co-occurrence phenomenon is very severe in training stage. We thus propose a Causal CAM (C-CAM) method to overcome the above challenges. Our method is motivated by two cause-effect chains including category-causality chain and anatomycausality chain. The category-causality chain represents the image content (cause) affects the category (effect). The anatomy-causality chain represents the anatomical structure (cause) affects the organ segmentation (effect). Extensive experiments were conducted on three public medical image data sets. Our C-CAM generates the best pseudo masks with the DSC of 77.26%, 80.34% and 78.15% on |
| 2021 | KernelCut baseline | Dice | 73.45% | split: val · annotation=hybrid · labeled-slices=10% | Weakly Supervised Volumetric Segmentation via Self-taught Shape Denoising ModelSource quoteL368: KernelCut\cite{tang2018regularized} │ Hybrid │ 80.18 │ 77.90 │ 77.58 │ 73.45 |
| 2020 | U-Net with context-based cross-entropy loss (StROI) proposed | Dice | 0.861 | split: val · roi=static 50×50 · loss=context-based cross-entropy · epochs=150 · evaluation=2D-slice · resolution=50x50 · architecture=U-Net | A Context Based Deep Learning Approach for Unbalanced Medical Image SegmentationSource quoteL103: \mathcal{L}-CONTEXT(StROI) (*) │ 0.861 │ 6.91 │ 0.85 │ 4.55 |
| 2020 | Seg-GLGAN (DyROI) proposed | Dice | 0.86 | split: val · roi=dynamic · epochs=150 · evaluation=2D-slice · architecture=Seg-GLGAN | A Context Based Deep Learning Approach for Unbalanced Medical Image SegmentationSource quoteL107: Seg-GLGAN(DyROI) (*) │ 0.86 │ 7.01 │ 0.856 │ 4.38 |
| 2020 | SIP-Net proposed | Overall challenge score | 89.18 | split: test | Selective Information Passing for MR/CT Image SegmentationSource quoteL220: The results of our proposed method and the competitors are shown in Table~\ref{tab:prostate_comparison}. Only the top 10 teams are listed. Note that all the results reported in this section were obtained directly from the challenge website. As it can be seen from the table, our overall performance was the best and therefore ranked the first place among all the teams (by May 22, 2018)\footnote{https://promise12.grand-challenge.org/evaluation/results/} with the score of 89.18. |
| 2020 | U-Net with global cross-entropy loss baseline | Dice | 0.7964 | split: val · loss=global cross-entropy · epochs=150 · evaluation=2D-slice · architecture=U-Net | A Context Based Deep Learning Approach for Unbalanced Medical Image SegmentationSource quoteL99: \multirow{6}{*}{U-Net} │ \mathcal{L}-CE │ 0.7964 │ 9.11 │ 0.822 │ 5.69 |
| 2020 | GAN baseline | Dice | 0.7877 | split: val · epochs=150 · evaluation=2D-slice · architecture=GAN | A Context Based Deep Learning Approach for Unbalanced Medical Image SegmentationSource quoteL105: \multirow{3}{*}{GAN} │ GAN │ 0.7877 │ 8.76 │ 0.833 │ 4.70 |
| 2019 | BOWDA-Net proposed | DSC | 92.54% | split: test · source-domain=Philips 3T · source-resampling=not resampled | Boundary-Weighted Domain Adaptive Neural Network for Prostate MR Image SegmentationSource quoteL303: BOWDA-Net │ {\bf 92.54} │ ---------\cr |
| 2019 | Ours (CRF\,+\,size) proposed non-standard slice | Mean 3D Dice | 0.807 | split: val · weakly-supervised · structure=prostate · size-bound=ε=0% | Discretely-constrained deep network for weakly supervised segmentationSource quoteL277: Ours (CRF\,+\,size) │ \bf{0.901} │ \bf{0.730} │ \bf{0.807} |
| 2019 | Domain adaptive network with cross entropy ablation | DSC | 90.38% | split: val · variant=cross-entropy · source-domain=Philips 3T · source-resampling=not resampled | Boundary-Weighted Domain Adaptive Neural Network for Prostate MR Image SegmentationSource quoteL266: Domain adaptive network with cross entropy │ 90.38 │ 0.00852\cr |
| 2019 | global and local CNNs | average Dice score | 90.6 | split: test | A deep learning-based method for prostate segmentation in T2-weighted magnetic resonance imagingSource quoteL13: We propose a novel automatic method for accurate segmentation of the prostate in T2-weighted magnetic resonance imaging (MRI). Our method is based on convolutional neural networks (CNNs). Because of the large variability in the shape, size, and appearance of the prostate and the scarcity of annotated training data, we suggest training two separate CNNs. A global CNN will determine a prostate bounding box, which is then resampled and sent to a local CNN for accurate delineation of the prostate boundary. This way, the local CNN can effectively learn to segment the fine details that distinguish the prostate from the surrounding tissue using the small amount of available training data. To fully exploit the training data, we synthesize additional data by deforming the training images and segmentations using a learned shape model. We apply the proposed method on the PROMISE12 challenge dataset and achieve state of the art results. Our proposed method generates accurate, smooth, and artifact-free segmentations. On the test images, we achieve an average Dice score of 90.6 with a small standard deviation of 2.2, which is superior to all previous methods. Our two-step segmentation approach and data augmentation strategy may be highly effective in segmentation of other organs from small amounts of annotated medical images. |
| 2019 | chen.junqiang under strategy-2 (mixing after resampling source domain data) baseline | DSC | 89.51% | split: test · strategy=mixing after source resampling · source-domain=Philips 3T | Boundary-Weighted Domain Adaptive Neural Network for Prostate MR Image SegmentationSource quoteL301: chen.junqiang\cite{chencode} under strategy-2 │ 89.51 │ 0.001072 |
| 2019 | Mehran et al. baseline | DSC | 81.09% | split: test · source-domain=Philips 3T | Boundary-Weighted Domain Adaptive Neural Network for Prostate MR Image SegmentationSource quoteL298: Mehran et al.~\cite{javanmardi2018domain} │ 81.09 │ 0.000056 \cr |
| 2019 | Penalty \cite{kervadec2018constrained} baseline non-standard slice | Mean 3D Dice | 0.588 | split: val · weakly-supervised · structure=prostate · size-bound=ε=0% | Discretely-constrained deep network for weakly supervised segmentationSource quoteL275: Penalty \cite{kervadec2018constrained} │ 0.813 │ 0.529 │ 0.588 |
| 2018 | Bridged U-net (Wnet), Cos-Dice Loss Q=1.7 proposed | Mean vDSC | 89.56% | split: val · Q=1.7 · loss=Cos-Dice | Prostate Segmentation using 2D Bridged U-netSource quoteL245: Mean vDSC\left[ % \right] \uparrow │ 85.57 │ 86.73 │ 89.56 |
| 2018 | DDSP ConNet (DDSP block; reweight-CE loss) ablation | Dice coefficient | 86.64% | loss=reweight-CE | Volumetric Densely Dilated Spatial Pooling ConNets for Prostate SegmentationSource quoteL281: 86.64% |
| 2018 | DDSP ConNet (DDSP block; DSC loss) ablation | Dice coefficient | 86.66% | loss=DSC | Volumetric Densely Dilated Spatial Pooling ConNets for Prostate SegmentationSource quoteL282: 86.66% |
| 2018 | DDSP ConNet (DDSP block; Jaccard loss) ablation | Dice coefficient | 86.38% | loss=Jaccard | Volumetric Densely Dilated Spatial Pooling ConNets for Prostate SegmentationSource quoteL283: 86.38% aspp |
| 2018 | Dice Loss ablation | Mean vDSC | 89.10% | split: val · loss=Dice | Prostate Segmentation using 2D Bridged U-netSource quoteL197: Dice Loss │ 89.10 |
| 2018 | U-net baseline | Mean vDSC | 86.73% | split: val | Prostate Segmentation using 2D Bridged U-netSource quoteL245: Mean vDSC\left[ % \right] \uparrow │ 85.57 │ 86.73 │ 89.56 |
| 2018 | Stacked U-net (table label: Stacked U) baseline | Mean vDSC | 85.57% | split: val | Prostate Segmentation using 2D Bridged U-netSource quoteL245: Mean vDSC\left[ % \right] \uparrow │ 85.57 │ 86.73 │ 89.56 |
| 2017 | proposed 2D FCN-preprocessor + FC-ResNet pipeline proposed | Dice coefficient (entire gland) | 87.4 | split: test · subset=30 images · modality=T2-weighted MRI | Learning normalized inputs for iterative estimation in medical image segmentationSource quoteL364: Overall, for our method the Dice coefficient is of 87.4 on the entire gland, with an average boundary distance of 2.17mm and a volume difference of 12.37%. The comparison to other FCNs on the prostate data is shown in Table \ref{tab:score_prostate}. In comparison, we use the score provided by the challenge organizer. As it can be seen, our pipeline outperforms other method based on 2D FCNs and is competitive with methods based on 3D FCNs. |
| 2017 | proposed 2D FCN-preprocessor + FC-ResNet pipeline proposed | average boundary distance | 2.17mm | split: test · subset=30 images · modality=T2-weighted MRI | Learning normalized inputs for iterative estimation in medical image segmentationSource quoteL364: Overall, for our method the Dice coefficient is of 87.4 on the entire gland, with an average boundary distance of 2.17mm and a volume difference of 12.37%. The comparison to other FCNs on the prostate data is shown in Table \ref{tab:score_prostate}. In comparison, we use the score provided by the challenge organizer. As it can be seen, our pipeline outperforms other method based on 2D FCNs and is competitive with methods based on 3D FCNs. |
| 2017 | proposed 2D FCN-preprocessor + FC-ResNet pipeline proposed | volume difference | 12.37% | split: test · subset=30 images · modality=T2-weighted MRI | Learning normalized inputs for iterative estimation in medical image segmentationSource quoteL364: Overall, for our method the Dice coefficient is of 87.4 on the entire gland, with an average boundary distance of 2.17mm and a volume difference of 12.37%. The comparison to other FCNs on the prostate data is shown in Table \ref{tab:score_prostate}. In comparison, we use the score provided by the challenge organizer. As it can be seen, our pipeline outperforms other method based on 2D FCNs and is competitive with methods based on 3D FCNs. |
| 2017 | Volumetric ConvNet (long-short connections) proposed | Dice coefficient | 86.93% | split: val · validation=10-fold-cross-validation | Volumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR ImagesSource quoteL96: 86.93 |
| 2017 | Volumetric ConvNet (only short connections) ablation | Dice coefficient | 84.68% | split: val · validation=10-fold-cross-validation | Volumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR ImagesSource quoteL98: 84.68 |
| 2017 | Volumetric ConvNet (only long connections) ablation | Dice coefficient | 84.38% | split: val · validation=10-fold-cross-validation | Volumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR ImagesSource quoteL100: 84.38 |
| 2017 | Volumetric ConvNet (without residual connections) ablation | Dice coefficient | 81.63% | split: val · validation=10-fold-cross-validation | Volumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR ImagesSource quoteL102: 81.63 erage of the probability maps of these sub-volumes to get the whole volume prediction. The sub-volume size was also |