PROMISE12

19 papers · 42 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on val (including prose scores where split is implicit).

81.283.385.387.420172018Volumetric ConvNet (without residual connections): 81.63 (2017)Volumetric ConvNet (only long connections): 84.38 (2017)Volumetric ConvNet (only short connections): 84.68 (2017)Volumetric ConvNet (long-short connections): 86.93 (2017)DDSP ConNet (DDSP block; Jaccard loss): 86.38 (2018)DDSP ConNet (DDSP block; reweight-CE loss): 86.64 (2018)DDSP ConNet (DDSP block; DSC loss): 86.66 (2018)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 16 of 16 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2021KernelCut baselineDice73.45%split: val · annotation=hybrid · labeled-slices=10%Weakly Supervised Volumetric Segmentation via Self-taught Shape Denoising Model
Source quote
L368: KernelCut\cite{tang2018regularized} │ Hybrid │ 80.18 │ 77.90 │ 77.58 │ 73.45
2020U-Net with context-based cross-entropy loss (StROI) proposedDice0.861split: val · roi=static 50×50 · loss=context-based cross-entropy · epochs=150 · evaluation=2D-slice · resolution=50x50 · architecture=U-NetA Context Based Deep Learning Approach for Unbalanced Medical Image Segmentation
Source quote
L103: \mathcal{L}-CONTEXT(StROI) (*) │ 0.861 │ 6.91 │ 0.85 │ 4.55
2020Seg-GLGAN (DyROI) proposedDice0.86split: val · roi=dynamic · epochs=150 · evaluation=2D-slice · architecture=Seg-GLGANA Context Based Deep Learning Approach for Unbalanced Medical Image Segmentation
Source quote
L107: Seg-GLGAN(DyROI) (*) │ 0.86 │ 7.01 │ 0.856 │ 4.38
2020U-Net with global cross-entropy loss baselineDice0.7964split: val · loss=global cross-entropy · epochs=150 · evaluation=2D-slice · architecture=U-NetA Context Based Deep Learning Approach for Unbalanced Medical Image Segmentation
Source quote
L99: \multirow{6}{*}{U-Net} │ \mathcal{L}-CE │ 0.7964 │ 9.11 │ 0.822 │ 5.69
2020GAN baselineDice0.7877split: val · epochs=150 · evaluation=2D-slice · architecture=GANA Context Based Deep Learning Approach for Unbalanced Medical Image Segmentation
Source quote
L105: \multirow{3}{*}{GAN} │ GAN │ 0.7877 │ 8.76 │ 0.833 │ 4.70
2019Ours (CRF\,+\,size) proposed non-standard sliceMean 3D Dice0.807split: val · weakly-supervised · structure=prostate · size-bound=ε=0%Discretely-constrained deep network for weakly supervised segmentation
Source quote
L277: Ours (CRF\,+\,size) │ \bf{0.901} │ \bf{0.730} │ \bf{0.807}
2019Domain adaptive network with cross entropy ablationDSC90.38%split: val · variant=cross-entropy · source-domain=Philips 3T · source-resampling=not resampledBoundary-Weighted Domain Adaptive Neural Network for Prostate MR Image Segmentation
Source quote
L266: Domain adaptive network with cross entropy │ 90.38 │ 0.00852\cr
2019Penalty \cite{kervadec2018constrained} baseline non-standard sliceMean 3D Dice0.588split: val · weakly-supervised · structure=prostate · size-bound=ε=0%Discretely-constrained deep network for weakly supervised segmentation
Source quote
L275: Penalty \cite{kervadec2018constrained} │ 0.813 │ 0.529 │ 0.588
2018Bridged U-net (Wnet), Cos-Dice Loss Q=1.7 proposedMean vDSC89.56%split: val · Q=1.7 · loss=Cos-DiceProstate Segmentation using 2D Bridged U-net
Source quote
L245: Mean vDSC\left[ % \right] \uparrow │ 85.57 │ 86.73 │ 89.56
2018Dice Loss ablationMean vDSC89.10%split: val · loss=DiceProstate Segmentation using 2D Bridged U-net
Source quote
L197: Dice Loss │ 89.10
2018U-net baselineMean vDSC86.73%split: valProstate Segmentation using 2D Bridged U-net
Source quote
L245: Mean vDSC\left[ % \right] \uparrow │ 85.57 │ 86.73 │ 89.56
2018Stacked U-net (table label: Stacked U) baselineMean vDSC85.57%split: valProstate Segmentation using 2D Bridged U-net
Source quote
L245: Mean vDSC\left[ % \right] \uparrow │ 85.57 │ 86.73 │ 89.56
2017Volumetric ConvNet (long-short connections) proposedDice coefficient86.93%split: val · validation=10-fold-cross-validationVolumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR Images
Source quote
L96: 86.93
2017Volumetric ConvNet (only short connections) ablationDice coefficient84.68%split: val · validation=10-fold-cross-validationVolumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR Images
Source quote
L98: 84.68
2017Volumetric ConvNet (only long connections) ablationDice coefficient84.38%split: val · validation=10-fold-cross-validationVolumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR Images
Source quote
L100: 84.38
2017Volumetric ConvNet (without residual connections) ablationDice coefficient81.63%split: val · validation=10-fold-cross-validationVolumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR Images
Source quote
L102: 81.63 erage of the probability maps of these sub-volumes to get the whole volume prediction. The sub-volume size was also