PROMISE12

19 papers · 42 extracted observations · medical image segmentation · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on val (including prose scores where split is implicit).

81.283.385.387.420172018Volumetric ConvNet (without residual connections): 81.63 (2017)Volumetric ConvNet (only long connections): 84.38 (2017)Volumetric ConvNet (only short connections): 84.68 (2017)Volumetric ConvNet (long-short connections): 86.93 (2017)DDSP ConNet (DDSP block; Jaccard loss): 86.38 (2018)DDSP ConNet (DDSP block; reweight-CE loss): 86.64 (2018)DDSP ConNet (DDSP block; DSC loss): 86.66 (2018)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 18 of 18 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026AutoMedImg-Claude-4.5-Opus proposedDice0.9517split: test · supervised · trials=Pass@3 · modality=MRI · dimension=2DTowards Fully Automated Medical Imaging Code Generation via Validation-based Context Engineering
Source quote
L376: \texttt{AutoMedImg-Claude-4.5-Opus} │ 0 │ 0.8185 │ 0 │ 0.9041 │ 0 │ 0.7696 │ 0 │ 0.8789 │ 0 │ 0.9517 │ 0 │ 0.9938
2025H-SAMora proposedMean Dice90.14few-shot · training-data=7.5%SAMora: Enhancing SAM through Hierarchical Self-Supervised Pre-Training for Medical Images
Source quote
L765: H-SAMora (Ours) │ 84.34 │ 92.46 │ 90.14
2024SemSim proposedDSC0.758split: test · semi-supervised · input=2D slices from 3D scans · labeled-data=3%SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L417: SemSim │ {\color[HTML]{FF0000}0.758} │ {\color[HTML]{FF0000}1.6} │ {\color[HTML]{FF0000}0.784} │ {\color[HTML]{FF0000}1.3}
2024SemSim proposedDSC0.784split: test · semi-supervised · input=2D slices from 3D scans · labeled-data=7%SemSim: Revisiting Weak-to-Strong Consistency from a Semantic Similarity Perspective for Semi-supervised Medical Image Segmentation
Source quote
L417: SemSim │ {\color[HTML]{FF0000}0.758} │ {\color[HTML]{FF0000}1.6} │ {\color[HTML]{FF0000}0.784} │ {\color[HTML]{FF0000}1.3}
2024CSA-Net proposedDSC0.921Binary prostate capsule segmentation.A Flexible 2.5D Medical Image Segmentation Approach with In-Slice and Cross-Slice Attention
Source quote
L190: CSA-Net │ 0.921 │ 1.06
2023Proposed method (TSD + MSLC; table label “Ours”) proposedreported segmentation score86.90test-time-adaptation · source_dataset=MSD05Feature Alignment and Uniformity for Test Time Adaptation
Source quote
L304: Ours │ 86.90 │ 86.78 │ 84.62 │ 80.89
2023SCP-Net proposedDSC77.06semi-supervised · labeled-scans=7 · unlabeled-scans=28Self-aware and Cross-sample Prototypical Learning for Semi-supervised Medical Image Segmentation
Source quote
L224: SCP-Net │ 7 │ 28 │ 77.06 │ 3.52
2022C-CAM proposedDSC77.26%split: test · weakly-supervised · supervision=image-levelC-CAM: Causal CAM for Weakly Supervised Semantic Segmentation on Medical Image
Source quote
L20: Recently, many excellent weakly supervised semantic segmentation (WSSS) works are proposed based on class activation mapping (CAM). However, there are few works that consider the characteristics of medical images. In this paper, we find that there are mainly two challenges of medical images in WSSS: i) the boundary of object foreground and background is not clear; ii) the co-occurrence phenomenon is very severe in training stage. We thus propose a Causal CAM (C-CAM) method to overcome the above challenges. Our method is motivated by two cause-effect chains including category-causality chain and anatomycausality chain. The category-causality chain represents the image content (cause) affects the category (effect). The anatomy-causality chain represents the anatomical structure (cause) affects the organ segmentation (effect). Extensive experiments were conducted on three public medical image data sets. Our C-CAM generates the best pseudo masks with the DSC of 77.26%, 80.34% and 78.15% on
2020U-Net with context-based cross-entropy loss (StROI) proposedDice0.861split: val · roi=static 50×50 · loss=context-based cross-entropy · epochs=150 · evaluation=2D-slice · resolution=50x50 · architecture=U-NetA Context Based Deep Learning Approach for Unbalanced Medical Image Segmentation
Source quote
L103: \mathcal{L}-CONTEXT(StROI) (*) │ 0.861 │ 6.91 │ 0.85 │ 4.55
2020Seg-GLGAN (DyROI) proposedDice0.86split: val · roi=dynamic · epochs=150 · evaluation=2D-slice · architecture=Seg-GLGANA Context Based Deep Learning Approach for Unbalanced Medical Image Segmentation
Source quote
L107: Seg-GLGAN(DyROI) (*) │ 0.86 │ 7.01 │ 0.856 │ 4.38
2020SIP-Net proposedOverall challenge score89.18split: testSelective Information Passing for MR/CT Image Segmentation
Source quote
L220: The results of our proposed method and the competitors are shown in Table~\ref{tab:prostate_comparison}. Only the top 10 teams are listed. Note that all the results reported in this section were obtained directly from the challenge website. As it can be seen from the table, our overall performance was the best and therefore ranked the first place among all the teams (by May 22, 2018)\footnote{https://promise12.grand-challenge.org/evaluation/results/} with the score of 89.18.
2019BOWDA-Net proposedDSC92.54%split: test · source-domain=Philips 3T · source-resampling=not resampledBoundary-Weighted Domain Adaptive Neural Network for Prostate MR Image Segmentation
Source quote
L303: BOWDA-Net │ {\bf 92.54} │ ---------\cr
2019Ours (CRF\,+\,size) proposed non-standard sliceMean 3D Dice0.807split: val · weakly-supervised · structure=prostate · size-bound=ε=0%Discretely-constrained deep network for weakly supervised segmentation
Source quote
L277: Ours (CRF\,+\,size) │ \bf{0.901} │ \bf{0.730} │ \bf{0.807}
2018Bridged U-net (Wnet), Cos-Dice Loss Q=1.7 proposedMean vDSC89.56%split: val · Q=1.7 · loss=Cos-DiceProstate Segmentation using 2D Bridged U-net
Source quote
L245: Mean vDSC\left[ % \right] \uparrow │ 85.57 │ 86.73 │ 89.56
2017proposed 2D FCN-preprocessor + FC-ResNet pipeline proposedDice coefficient (entire gland)87.4split: test · subset=30 images · modality=T2-weighted MRILearning normalized inputs for iterative estimation in medical image segmentation
Source quote
L364: Overall, for our method the Dice coefficient is of 87.4 on the entire gland, with an average boundary distance of 2.17mm and a volume difference of 12.37%. The comparison to other FCNs on the prostate data is shown in Table \ref{tab:score_prostate}. In comparison, we use the score provided by the challenge organizer. As it can be seen, our pipeline outperforms other method based on 2D FCNs and is competitive with methods based on 3D FCNs.
2017proposed 2D FCN-preprocessor + FC-ResNet pipeline proposedaverage boundary distance2.17mmsplit: test · subset=30 images · modality=T2-weighted MRILearning normalized inputs for iterative estimation in medical image segmentation
Source quote
L364: Overall, for our method the Dice coefficient is of 87.4 on the entire gland, with an average boundary distance of 2.17mm and a volume difference of 12.37%. The comparison to other FCNs on the prostate data is shown in Table \ref{tab:score_prostate}. In comparison, we use the score provided by the challenge organizer. As it can be seen, our pipeline outperforms other method based on 2D FCNs and is competitive with methods based on 3D FCNs.
2017proposed 2D FCN-preprocessor + FC-ResNet pipeline proposedvolume difference12.37%split: test · subset=30 images · modality=T2-weighted MRILearning normalized inputs for iterative estimation in medical image segmentation
Source quote
L364: Overall, for our method the Dice coefficient is of 87.4 on the entire gland, with an average boundary distance of 2.17mm and a volume difference of 12.37%. The comparison to other FCNs on the prostate data is shown in Table \ref{tab:score_prostate}. In comparison, we use the score provided by the challenge organizer. As it can be seen, our pipeline outperforms other method based on 2D FCNs and is competitive with methods based on 3D FCNs.
2017Volumetric ConvNet (long-short connections) proposedDice coefficient86.93%split: val · validation=10-fold-cross-validationVolumetric ConvNets with Mixed Residual Connections for Automated Prostate Segmentation from 3D MR Images
Source quote
L96: 86.93