OrganAMNIST

7 papers · 10 extracted observations · image classification · vision · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

56.667.277.888.4202320252027SFHarmony: 86.22 (2023)CCSI: 68.7 (2024)Aegis: 58.8 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 10 of 10 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Learned optical compression (fixed encoder ℰ₀, experimentally adapted decoder 𝒟exp) proposedPSNR17.5 dBsplit: test · experimental-transfer-learning-t-450Learned optical compression for single-pixel quantitative phase imaging
Source quote
L437: an increase of about 2–3 dB in PSNR over zero-shot. OrganAMNIST reaches 0.761 (17.5 dB),
2026Aegis proposedACC58.8%Original non-IID partition (at most 5 classes); Aegis setting against Robbing-the-Fed; …Aegis: Generative Gradient Masking for Privacy-Preserving Medical Federated Learning
Source quote
L536: Original: at most 5 classes │ 58.8 │ 11.63 │ 20.10 │ 0.51
2026Aegis against Robbing-the-Fed proposedRR11.63%Original non-IID partition (at most 5 classes); B=64, M=2048, k=1024, 10% client partic…Aegis: Generative Gradient Masking for Privacy-Preserving Medical Federated Learning
Source quote
L536: Original: at most 5 classes │ 58.8 │ 11.63 │ 20.10 │ 0.51
2026VIVID-Med proposedmacro-AUC0.9969modality=CT · pretraining-modality=chest X-rayVIVID-Med: LLM-Supervised Structured Pretraining for Deployable Medical ViTs
Source quote
L4: Vision-language pretraining has driven significant progress in medical image analysis. However, current methods typically supervise visual encoders using one-hot labels or free-form text, neither of which effectively captures the complex semantic relationships among clinical findings. In this study, we introduce VIVID-Med, a novel framework that leverages a frozen large language model (LLM) as a structured semantic teacher to pretrain medical vision transformers (ViTs). VIVID-Med translates clinical findings into verifiable JSON field-state pairs via a Unified Medical Schema (UMS), utilizing answerability-aware masking to focus optimization. It then employs Structured Prediction Decomposition (SPD) to partition cross-attention into orthogonality-regularized query groups, extracting complementary visual aspects. Crucially, the LLM is discarded post-training, yielding a lightweight, deployable ViT-only backbone. We evaluated VIVID-Med across multiple settings: on CheXpert linear probing, it achieves a macro-AUC of 0.8588, outperforming BiomedCLIP by {+}6.65 points while using 500× less data. It also demonstrates robust zero-shot cross-domain transfer to NIH ChestX-ray14 (0.7225 macro-AUC) and strong cross-modality generalization to CT, achieving 0.8413 AUC on LIDC-IDRI lung nodule classification and 0.9969 macro-AUC on OrganAMNIST 11-organ classification. VIVID-Med offers a highly efficient, scalable alternative to deploying resource-heavy vision-language models in clinical settings.
2024CCSI proposedAccuracy over all tasks68.70%split: testCCSI: Continual Class-Specific Impression for Data-free Class Incremental Learning
Source quote
L421: \texttt{CCSI}\xspace (ours) │ Synthesized │ 79.10 │ 56.30 │ 68.70 │ 28.00 │ 83.66
2023L3DMC (table label: Ours) proposedAccuracy ↑71.01class-incremental · tasks=4 · memory=200 exemplarsL3DMC: Lifelong Learning using Distillation via Mixed-Curvature Space
Source quote
L193: Ours │ 71.98 │ 14.62 │ 60.60 │ 21.18 │ 71.01 │ 13.88
2023Medi-CAT (AT + Contrastive; Proposed) proposedAccuracy0.961Accuracy score; split not specified in the table.Medi-CAT: Contrastive Adversarial Training for Medical Image Classification
Source quote
L170: AT + Contrastive (Proposed) │ 0.824 │ 0.961 │ 0.940 │ 0.843
2023SFHarmony proposedaverage accuracy86.22%sites=5 · batchsize=5SFHarmony: Source Free Domain Adaptation for Distributed Neuroimaging Analysis
Source quote
L255: The results can be seen in Table 1, alongside the baseline methods. It can be seen that SFHarmony outperforms the existing SFDA methods, especially when a small batchsize was used for training (86.22% for batchsize 5). SHOT [33] showed comparable performance to SFHarmony when trained with a batchsize of 500 (85.27%), but was highly dependent on the modified source training. Interestingly, several of the SFDA approaches outperformed the adversarial approaches despite them having access to the source data, possibly due to the instability of such approaches.
2023iCARL baselineAccuracy ↑63.02class-incremental · tasks=4 · memory=200 exemplarsL3DMC: Lifelong Learning using Distillation via Mixed-Curvature Space
Source quote
L191: iCARL~\cite{rebuffi2017icarl} │ 67.70 │ 14.52 │ 58.46 │ -0.70 │ 63.02 │ 7.75
2023SHOT baselineaverage accuracy85.27%sites=5 · batchsize=500SFHarmony: Source Free Domain Adaptation for Distributed Neuroimaging Analysis
Source quote
L255: The results can be seen in Table 1, alongside the baseline methods. It can be seen that SFHarmony outperforms the existing SFDA methods, especially when a small batchsize was used for training (86.22% for batchsize 5). SHOT [33] showed comparable performance to SFHarmony when trained with a batchsize of 500 (85.27%), but was highly dependent on the modified source training. Interestingly, several of the SFDA approaches outperformed the adversarial approaches despite them having access to the source data, possibly due to the instability of such approaches.