NLST

21 papers · 59 extracted observations · sinogram standardization · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

0.70.80.91.0202120232026Tri2D-Net: 0.768 (2020)Tri2D-Net: 0.871 (2020)Deep learning model: 0.96 (2022)3D-morphomics: 0.964 (2022)Radiomics: 0.976 (2022)3D-morphomics+Radiomics: 0.978 (2022)PARE: 0.928 (2023)PARE (ensemble of multiple deep supervision heads): 0.931 (2023)3D VGG16: 0.68 (2025)3D Res18: 0.69 (2025)ABC-tensor: 0.759 (2026)AdaFuse: 0.762 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 59 of 59 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026AdaFuse proposedAUC0.762split: testAdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement Learning
Source quote
L277: AdaFuse (Ours) │ 0.762 │ [0.657, 0.860]
2026Artifact-based agent framework with DeepSeek (deepseek-r1:14b), artifact contract disabled proposedFilter accuracy (exact match)20%model=DeepSeek-R1-14B · params=14b · artifact-contract=disabledAn Artifact-based Agent Framework for Adaptive and Reproducible Medical Image Processing
Source quote
L225: \texttt{DeepSeek} │ \ding{55} │ 95% │ 20% │ 80%
2026Artifact-based agent framework with DeepSeek (deepseek-r1:14b), artifact contract enabled proposedFilter accuracy (exact match)95%model=DeepSeek-R1-14B · params=14b · artifact-contract=enabledAn Artifact-based Agent Framework for Adaptive and Reproducible Medical Image Processing
Source quote
L231: \texttt{DeepSeek} │ \checkmark │ {\color{blue}100%} │ {\color{blue}95%} │ {\color{blue}100%}
2026ABC-tensorAUC0.759split: testAdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement Learning
Source quote
L278: ABC-tensor │ 0.759 │ [0.646, 0.863] │ 0.898
2026Real baseline LDCT baselineAUROC0.742timepoint=baseline · image-source=real LDCTNodule-Aligned Latent Space Learning with LLM-Driven Multimodal Diffusion for Lung Nodule Progression Prediction
Source quote
L163: Real baseline LDCT │ 0.742 │ 0.263
2026Real baseline LDCT baselineAUPRC0.263timepoint=baseline · image-source=real LDCTNodule-Aligned Latent Space Learning with LLM-Driven Multimodal Diffusion for Lung Nodule Progression Prediction
Source quote
L163: Real baseline LDCT │ 0.742 │ 0.263
2026Real follow-up LDCT baselineAUROC0.819timepoint=follow-up · image-source=real LDCTNodule-Aligned Latent Space Learning with LLM-Driven Multimodal Diffusion for Lung Nodule Progression Prediction
Source quote
L164: Real follow-up LDCT │ 0.819 │ 0.393
2026Real follow-up LDCT baselineAUPRC0.393timepoint=follow-up · image-source=real LDCTNodule-Aligned Latent Space Learning with LLM-Driven Multimodal Diffusion for Lung Nodule Progression Prediction
Source quote
L164: Real follow-up LDCT │ 0.819 │ 0.393
2026DynMM baselineAUC0.754split: testAdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement Learning
Source quote
L281: DynMM │ 0.754 │ [0.640, 0.855] │ 0.829
2026MoE baselineAUC0.742split: testAdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement Learning
Source quote
L284: MoE │ 0.742 │ [0.628, 0.847] │ 0.666
2026A (CT) baselineAUC0.732split: testAdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement Learning
Source quote
L289: A (CT) │ 0.732 │ [0.609, 0.842] │ 0.116
2025UniSino proposedPSNR48.938split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L140: 48.938 / 97.331 / 0.00353
2025UniSino proposedSSIM97.331split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L140: 48.938 / 97.331 / 0.00353
2025UniSino proposedNRMSE0.00353split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L140: 48.938 / 97.331 / 0.00353
2025Multipath cycleGAN proposedmedian percent emphysema10.13%method=Multipath cycleGAN · source-kernel=Philips D · target-kernel=Siemens B30fMultipath cycleGAN for harmonization of paired and unpaired low-dose lung computed tomography reconstruction kernels
Source quote
L160: GE STANDARD and GE LUNG but overcorrected Philips D (median 10.13%) and Philips C (9.13%).
2025Multipath cycleGAN proposedmedian percent emphysema9.13%method=Multipath cycleGAN · source-kernel=Philips C · target-kernel=Siemens B30fMultipath cycleGAN for harmonization of paired and unpaired low-dose lung computed tomography reconstruction kernels
Source quote
L160: GE STANDARD and GE LUNG but overcorrected Philips D (median 10.13%) and Philips C (9.13%).
2025U-Net baselinePSNR43.987split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L137: 43.987 / 98.701 / 0.0062
2025U-Net baselineSSIM98.701split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L137: 43.987 / 98.701 / 0.0062
2025U-Net baselineNRMSE0.0062split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L137: 43.987 / 98.701 / 0.0062
2025CT foundation model baselineAUROC0.729prediction-horizon=2-yearLearning Contrastive Multimodal Fusion with Improved Modality Dropout for Disease Detection and Prediction
Source quote
L175: CT foundation model \cite{yang_advancing_2024} │ 0.729 │ 0.070 │ 0.956 │ 0.700 │ 0.050 │ 0.972
2025CT foundation model baselineAUROC0.700prediction-horizon=1-yearLearning Contrastive Multimodal Fusion with Improved Modality Dropout for Disease Detection and Prediction
Source quote
L175: CT foundation model \cite{yang_advancing_2024} │ 0.729 │ 0.070 │ 0.956 │ 0.700 │ 0.050 │ 0.972
2025RAD-DINO baselinepatient-level ROC-AUC0.646split: test · head=MLP · input=raw · encoder=frozen · pooling=meanVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L163: RAD-DINO │ 0.646 vs.\ 0.683 │ < 0.004
2025RAD-DINO baselinepatient-level ROC-AUC0.683split: test · head=MLP · input=Virtual-Eyes-preprocessed · encoder=frozen · pooling=meanVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L163: RAD-DINO │ 0.646 vs.\ 0.683 │ < 0.004
2025Sybil baselinepatient-level ROC-AUC0.886split: test · input=raw · pooling=mean · backbone_retrained=falseVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L164: Sybil │ 0.886 vs.\ 0.837 │ 0.021
2025Sybil baselinepatient-level ROC-AUC0.837split: test · input=Virtual-Eyes-preprocessed · pooling=mean · backbone_retrained=falseVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L164: Sybil │ 0.886 vs.\ 0.837 │ 0.021
2025ResNet-18 baselinepatient-level ROC-AUC0.571split: test · input=raw · pooling=mean · backbone=ResNet-18 · backbone_retrained=falseVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L165: ResNet-18 │ 0.571 vs.\ 0.596 │ 0.043
2025ResNet-18 baselinepatient-level ROC-AUC0.596split: test · input=Virtual-Eyes-preprocessed · pooling=mean · backbone=ResNet-18 · backbone_retrained=falseVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L165: ResNet-18 │ 0.571 vs.\ 0.596 │ 0.043
2025Siemens B30f reference kernel baselinemedian percent emphysema6.60%reference-kernel=Siemens B30fMultipath cycleGAN for harmonization of paired and unpaired low-dose lung computed tomography reconstruction kernels
Source quote
L155: We visualize the emphysema distributions before and after harmonization using boxplots overlaid with strip plots as seen in Figure 5. We represent all measurements as the median emphysema measurements. The reference Siemens B30f kernel, had a median of 6.60%.
2024Ours + MIND (DIO) proposedTRE301.02 mmsplit: val · feature=MIND · method-variant=DIODeep implicit optimization enables robust learnable features for deformable image registration
Source quote
L638: Ours + MIND │ 1.02
20243D Res18 proposedAUC0.690input=most-recent CT · sample-size=1882 · nodule-crops=top-fiveImproving lung cancer diagnosis and survival prediction with deep learning and CT imaging
Source quote
L528: 3D Res18 │ 0.690 │ 0.601
20243D Res18 proposedC-index0.601input=most-recent CT · population=cancer and non-cancer groups · sample-size=1882 · nodule-crops=top-fiveImproving lung cancer diagnosis and survival prediction with deep learning and CT imaging
Source quote
L528: 3D Res18 │ 0.690 │ 0.601
20243D VGG16 proposedAUC0.680input=most-recent CT · sample-size=1882 · nodule-crops=top-fiveImproving lung cancer diagnosis and survival prediction with deep learning and CT imaging
Source quote
L530: 3D VGG16 │ 0.680 │ 0.608
20243D VGG16 proposedC-index0.608input=most-recent CT · population=cancer and non-cancer groups · sample-size=1882 · nodule-crops=top-fiveImproving lung cancer diagnosis and survival prediction with deep learning and CT imaging
Source quote
L530: 3D VGG16 │ 0.680 │ 0.608
2024SAMCL proposedAVG TRE3.855 mmsplit: test · continual-learning · registration-type=intra-subjectToward Universal Medical Image Registration via Sharpness-Aware Meta-Continual Learning
Source quote
L152: SAMCL │ 0.697/0.352/3.855/0.563 │ -0.037/-0.039/0.306/0
2024ConvexAdam + MIND baselineTRE301.17 mmsplit: val · feature=MINDDeep implicit optimization enables robust learnable features for deformable image registration
Source quote
L637: ConvexAdam + MIND │ 1.17
2024Pretrained cancer classifier (Liao et al.) baselineAUC0.550input=most-recent CT · reference=Liao et al. pretrained classifier · sample-size=1882 · nodule-crops=top-fiveImproving lung cancer diagnosis and survival prediction with deep learning and CT imaging
Source quote
L532: Pretrained │ 0.550 │ 0.519
2024Pretrained cancer classifier (Liao et al.) baselineC-index0.519input=most-recent CT · reference=Liao et al. pretrained classifier · population=cancer and non-cancer groups · sample-size=1882 · nodule-crops=top-fiveImproving lung cancer diagnosis and survival prediction with deep learning and CT imaging
Source quote
L532: Pretrained │ 0.550 │ 0.519
2023Study H CRNN (ResNet+LSTM, hx=32) proposedIPCW C-index0.7505-fold-cv · input=all available follow-up imaging · backbone=ResNet+LSTM · hidden-size=32A hybrid CNN-RNN approach for survival analysis in a Lung Cancer Screening study
Source quote
L225: H. CRNN │ ResNet+LSTM │ 32 │ 0.750 (0.050) │ 0.690 (0.019)
2023PARE (ensemble of multiple deep supervision heads) proposedAUC0.931split: test · variant=ensemble of multiple deep supervision headsParse and Recall: Towards Accurate Lung Nodule Malignancy Prediction Like Radiologists
Source quote
L196: Moreover, by utilizing the ensemble of multiple deep supervision heads, the overall AUC is further improved to 0.931 on both datasets.
2023PARE proposedAUC0.928split: testParse and Recall: Towards Accurate Lung Nodule Malignancy Prediction Like Radiologists
Source quote
L209: PARE^\diamond │ \multicolumn{1}{c|}{0.882} │ \multicolumn{1}{c|}{0.770} │ \multicolumn{1}{c|}{0.826} │ 0.928 │ \multicolumn{1}{c|}{0.892} │ \multicolumn{1}{c|}{0.817} │ \multicolumn{1}{c|}{0.783} │ 0.927
2023RWCNet with single resolution (4x) ablationNLST TRE5.52 mmsplit: val · resolution=4x downsampling · configuration=single-resolutionRecurrence With Correlation Network for Medical Image Registration
Source quote
L116: RWCNet with single resolution (4x) │ 5.52 │ 74
2023Study G CNN (ResNet) baselineIPCW C-index0.7195-fold-cv · input=latest CT scan · backbone=ResNetA hybrid CNN-RNN approach for survival analysis in a Lung Cancer Screening study
Source quote
L224: G. CNN │ ResNet │ 0.719 (0.040) │ 0.673 (0.009)
2023LAPIRN baselineNLST TRE5.51 mmsplit: val · training-loss=supervised-keypoint-discrepancy · similarity-loss=MSERecurrence With Correlation Network for Medical Image Registration
Source quote
L100: LAPIRN \cite{mok_large_2020} │ 5.51 │ 80.0
2022Deep learning model proposedAUC (Black vs White)0.96aggregation=study-level; average of slice predictionsAI recognition of patient race in medical imaging: a modelling study
Source quote
L488: 0.92 (slice), 0.96 (study)
2022Proposed censor-aware semi-supervised survival-time method proposedMAE (all samples)26.28 daysMain comparison table; all samples.Censor-aware Semi-supervised Learning for Survival Time Prediction from Medical Images
Source quote
L248: Ours │ 26.28 │ 1275.24 │ 0.756
2022Proposed censor-aware semi-supervised survival-time method proposedC-index0.756Main comparison table; no separate sample subgroup is specified for this metric.Censor-aware Semi-supervised Learning for Survival Time Prediction from Medical Images
Source quote
L248: Ours │ 26.28 │ 1275.24 │ 0.756
2022DSCA proposedMean C-Index0.66803split: val · patch-magnification=5× low-resolution and 20× high-resolutionDSCA: A dual-stream network with cross-attention on whole-slide image pyramids for cancer prognosis
Source quote
L265: DSCA (ours) │ 0.66803 (0.05817) │ 0.61224 (0.05350) │ 0.70181 (0.04321) │ 6.31M │ 2.51G
20223D-morphomicsAUC0.964split: test3D-Morphomics, Morphological Features on CT scans for lung nodule malignancy diagnosis
Source quote
L121: 3D-morphomics (NLST) │ 0.964 │ 90.7 │ 91.1 │ 0.94 │ 0.964±0.006[0.952 0.976]
20223D-morphomics+RadiomicsAUC0.978split: test3D-Morphomics, Morphological Features on CT scans for lung nodule malignancy diagnosis
Source quote
L126: 3D-morphomics+Radiomics (NLST) │ 0.978 │ 92.7 │ 94.7 │ 0.95 │ 0.979±0.004[0.971 0.986]
2022RadiomicsAUC0.976split: test3D-Morphomics, Morphological Features on CT scans for lung nodule malignancy diagnosis
Source quote
L122: Radiomics (NLST) │ 0.976 │ 92.7 │ 93.6 │ 0.94 │ 0.977±0.004[0.968 0.984]
2022DeepConvSurvMAE (all samples)27.98 daysMain comparison table; all samples.Censor-aware Semi-supervised Learning for Survival Time Prediction from Medical Images
Source quote
L247: DeepConvSurv~\cite{zhu_deep_2016} │ 27.98 │ 1334.22 │ 0.690
2021Proposed IQA tool — Slice Distance Check proposedSlice Distance Check failure rate3.9%subset=confirmed-diagnosis scansTechnical Report: Quality Assessment Tool for Machine Learning with Clinical CT
Source quote
L133: 3.9%
2021Proposed IQA tool — Resolution Filtering proposedResolution Filtering failure rate0.99%subset=confirmed-diagnosis scansTechnical Report: Quality Assessment Tool for Machine Learning with Clinical CT
Source quote
L142: 0.99%
2020Tri2D-Net proposedAUC0.871split: test · input=low-dose-CT · test_subjects=2085Deep Learning Predicts Cardiovascular Disease Risks from Lung Cancer Screening Low Dose Computed Tomography
Source quote
L11: Cancer patients have a higher risk of cardiovascular disease (CVD) mortality than the general population. Low dose computed tomography (LDCT) for lung cancer screening offers an opportunity for simultaneous CVD risk estimation in at-risk patients. Our deep learning CVD risk prediction model, trained with 30,286 LDCTs from the National Lung Cancer Screening Trial, achieved an area under the curve (AUC) of 0.871 on a separate test set of 2,085 subjects and identified patients with high CVD mortality risks (AUC of 0.768). We validated our model against ECG-gated cardiac CT based markers, including coronary artery calcification (CAC) score, CAD-RADS score, and MESA 10-year risk score from an independent dataset of 335 subjects. Our work shows that, in high-risk patients, deep learning can convert LDCT for lung cancer screening into a dual-screening quantitative tool for CVD risk estimation.
2020Tri2D-Net proposedAUC0.768split: test · input=low-dose-CTDeep Learning Predicts Cardiovascular Disease Risks from Lung Cancer Screening Low Dose Computed Tomography
Source quote
L11: Cancer patients have a higher risk of cardiovascular disease (CVD) mortality than the general population. Low dose computed tomography (LDCT) for lung cancer screening offers an opportunity for simultaneous CVD risk estimation in at-risk patients. Our deep learning CVD risk prediction model, trained with 30,286 LDCTs from the National Lung Cancer Screening Trial, achieved an area under the curve (AUC) of 0.871 on a separate test set of 2,085 subjects and identified patients with high CVD mortality risks (AUC of 0.768). We validated our model against ECG-gated cardiac CT based markers, including coronary artery calcification (CAC) score, CAD-RADS score, and MESA 10-year risk score from an independent dataset of 335 subjects. Our work shows that, in high-risk patients, deep learning can convert LDCT for lung cancer screening into a dual-screening quantitative tool for CVD risk estimation.
2019DLSTM proposedF1 score0.7085split: val · subjects=1,794 · time-points=2 · cross-validation=5-foldDistanced LSTM: Time-Distanced Gates in Long Short-Term Memory Models for Lung Cancer Detection
Source quote
L8: 0.6785 to 0.7085 on F1 score in NLST). In external validation of clinically and irregularly acquired data, the benchmarks achieved 0.8350 (CNN feature) and
2019LSTM baselineF1 score0.6785split: val · subjects=1,794 · time-points=2 · cross-validation=5-foldDistanced LSTM: Time-Distanced Gates in Long Short-Term Memory Models for Lung Cancer Detection
Source quote
L8: 0.6785 to 0.7085 on F1 score in NLST). In external validation of clinically and irregularly acquired data, the benchmarks achieved 0.8350 (CNN feature) and
2017LASSO-Cox [23] with WSISA features proposedC-index0.703split: test · features=WSISAWSISA: Making Survival Prediction from Whole Slide Histopathological Images
Source quote
L276: 0.703
2017LASSO-Cox [23] with ROI-based features baselineC-index0.503split: test · features=ROI-basedWSISA: Making Survival Prediction from Whole Slide Histopathological Images
Source quote
L275: 0.503