NLST

21 papers · 59 extracted observations · sinogram standardization · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

0.70.80.91.0202120232026Tri2D-Net: 0.768 (2020)Tri2D-Net: 0.871 (2020)Deep learning model: 0.96 (2022)3D-morphomics: 0.964 (2022)Radiomics: 0.976 (2022)3D-morphomics+Radiomics: 0.978 (2022)PARE: 0.928 (2023)PARE (ensemble of multiple deep supervision heads): 0.931 (2023)3D VGG16: 0.68 (2025)3D Res18: 0.69 (2025)ABC-tensor: 0.759 (2026)AdaFuse: 0.762 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 27 of 27 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026AdaFuse proposedAUC0.762split: testAdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement Learning
Source quote
L277: AdaFuse (Ours) │ 0.762 │ [0.657, 0.860]
2026ABC-tensorAUC0.759split: testAdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement Learning
Source quote
L278: ABC-tensor │ 0.759 │ [0.646, 0.863] │ 0.898
2026DynMM baselineAUC0.754split: testAdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement Learning
Source quote
L281: DynMM │ 0.754 │ [0.640, 0.855] │ 0.829
2026MoE baselineAUC0.742split: testAdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement Learning
Source quote
L284: MoE │ 0.742 │ [0.628, 0.847] │ 0.666
2026A (CT) baselineAUC0.732split: testAdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement Learning
Source quote
L289: A (CT) │ 0.732 │ [0.609, 0.842] │ 0.116
2025UniSino proposedPSNR48.938split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L140: 48.938 / 97.331 / 0.00353
2025UniSino proposedSSIM97.331split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L140: 48.938 / 97.331 / 0.00353
2025UniSino proposedNRMSE0.00353split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L140: 48.938 / 97.331 / 0.00353
2025U-Net baselinePSNR43.987split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L137: 43.987 / 98.701 / 0.0062
2025U-Net baselineSSIM98.701split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L137: 43.987 / 98.701 / 0.0062
2025U-Net baselineNRMSE0.0062split: test · resolution=384×384UniSino: Physics-Driven Foundational Model for Universal CT Sinogram Standardization
Source quote
L137: 43.987 / 98.701 / 0.0062
2025RAD-DINO baselinepatient-level ROC-AUC0.646split: test · head=MLP · input=raw · encoder=frozen · pooling=meanVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L163: RAD-DINO │ 0.646 vs.\ 0.683 │ < 0.004
2025RAD-DINO baselinepatient-level ROC-AUC0.683split: test · head=MLP · input=Virtual-Eyes-preprocessed · encoder=frozen · pooling=meanVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L163: RAD-DINO │ 0.646 vs.\ 0.683 │ < 0.004
2025Sybil baselinepatient-level ROC-AUC0.886split: test · input=raw · pooling=mean · backbone_retrained=falseVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L164: Sybil │ 0.886 vs.\ 0.837 │ 0.021
2025Sybil baselinepatient-level ROC-AUC0.837split: test · input=Virtual-Eyes-preprocessed · pooling=mean · backbone_retrained=falseVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L164: Sybil │ 0.886 vs.\ 0.837 │ 0.021
2025ResNet-18 baselinepatient-level ROC-AUC0.571split: test · input=raw · pooling=mean · backbone=ResNet-18 · backbone_retrained=falseVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L165: ResNet-18 │ 0.571 vs.\ 0.596 │ 0.043
2025ResNet-18 baselinepatient-level ROC-AUC0.596split: test · input=Virtual-Eyes-preprocessed · pooling=mean · backbone=ResNet-18 · backbone_retrained=falseVirtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk Prediction
Source quote
L165: ResNet-18 │ 0.571 vs.\ 0.596 │ 0.043
2024SAMCL proposedAVG TRE3.855 mmsplit: test · continual-learning · registration-type=intra-subjectToward Universal Medical Image Registration via Sharpness-Aware Meta-Continual Learning
Source quote
L152: SAMCL │ 0.697/0.352/3.855/0.563 │ -0.037/-0.039/0.306/0
2023PARE (ensemble of multiple deep supervision heads) proposedAUC0.931split: test · variant=ensemble of multiple deep supervision headsParse and Recall: Towards Accurate Lung Nodule Malignancy Prediction Like Radiologists
Source quote
L196: Moreover, by utilizing the ensemble of multiple deep supervision heads, the overall AUC is further improved to 0.931 on both datasets.
2023PARE proposedAUC0.928split: testParse and Recall: Towards Accurate Lung Nodule Malignancy Prediction Like Radiologists
Source quote
L209: PARE^\diamond │ \multicolumn{1}{c|}{0.882} │ \multicolumn{1}{c|}{0.770} │ \multicolumn{1}{c|}{0.826} │ 0.928 │ \multicolumn{1}{c|}{0.892} │ \multicolumn{1}{c|}{0.817} │ \multicolumn{1}{c|}{0.783} │ 0.927
20223D-morphomicsAUC0.964split: test3D-Morphomics, Morphological Features on CT scans for lung nodule malignancy diagnosis
Source quote
L121: 3D-morphomics (NLST) │ 0.964 │ 90.7 │ 91.1 │ 0.94 │ 0.964±0.006[0.952 0.976]
20223D-morphomics+RadiomicsAUC0.978split: test3D-Morphomics, Morphological Features on CT scans for lung nodule malignancy diagnosis
Source quote
L126: 3D-morphomics+Radiomics (NLST) │ 0.978 │ 92.7 │ 94.7 │ 0.95 │ 0.979±0.004[0.971 0.986]
2022RadiomicsAUC0.976split: test3D-Morphomics, Morphological Features on CT scans for lung nodule malignancy diagnosis
Source quote
L122: Radiomics (NLST) │ 0.976 │ 92.7 │ 93.6 │ 0.94 │ 0.977±0.004[0.968 0.984]
2020Tri2D-Net proposedAUC0.871split: test · input=low-dose-CT · test_subjects=2085Deep Learning Predicts Cardiovascular Disease Risks from Lung Cancer Screening Low Dose Computed Tomography
Source quote
L11: Cancer patients have a higher risk of cardiovascular disease (CVD) mortality than the general population. Low dose computed tomography (LDCT) for lung cancer screening offers an opportunity for simultaneous CVD risk estimation in at-risk patients. Our deep learning CVD risk prediction model, trained with 30,286 LDCTs from the National Lung Cancer Screening Trial, achieved an area under the curve (AUC) of 0.871 on a separate test set of 2,085 subjects and identified patients with high CVD mortality risks (AUC of 0.768). We validated our model against ECG-gated cardiac CT based markers, including coronary artery calcification (CAC) score, CAD-RADS score, and MESA 10-year risk score from an independent dataset of 335 subjects. Our work shows that, in high-risk patients, deep learning can convert LDCT for lung cancer screening into a dual-screening quantitative tool for CVD risk estimation.
2020Tri2D-Net proposedAUC0.768split: test · input=low-dose-CTDeep Learning Predicts Cardiovascular Disease Risks from Lung Cancer Screening Low Dose Computed Tomography
Source quote
L11: Cancer patients have a higher risk of cardiovascular disease (CVD) mortality than the general population. Low dose computed tomography (LDCT) for lung cancer screening offers an opportunity for simultaneous CVD risk estimation in at-risk patients. Our deep learning CVD risk prediction model, trained with 30,286 LDCTs from the National Lung Cancer Screening Trial, achieved an area under the curve (AUC) of 0.871 on a separate test set of 2,085 subjects and identified patients with high CVD mortality risks (AUC of 0.768). We validated our model against ECG-gated cardiac CT based markers, including coronary artery calcification (CAC) score, CAD-RADS score, and MESA 10-year risk score from an independent dataset of 335 subjects. Our work shows that, in high-risk patients, deep learning can convert LDCT for lung cancer screening into a dual-screening quantitative tool for CVD risk estimation.
2017LASSO-Cox [23] with WSISA features proposedC-index0.703split: test · features=WSISAWSISA: Making Survival Prediction from Whole Slide Histopathological Images
Source quote
L276: 0.703
2017LASSO-Cox [23] with ROI-based features baselineC-index0.503split: test · features=ROI-basedWSISA: Making Survival Prediction from Whole Slide Histopathological Images
Source quote
L275: 0.503