NLST
21 papers · 59 extracted observations · sinogram standardization · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | 3D-morphomics+Radiomics SOTA frontier (+2 variants) | 0.978 | 2022-07-01 | Model trained on the NLST train-validation set and evaluated on the NLST test set. | 3D-Morphomics, Morphological Features on CT scans for lung nodule malignancy diagnosisSource quote3D-morphomics+Radiomics (NLST) │ 0.978 │ 92.7 │ 94.7 │ 0.95 │ 0.979±0.004[0.971 0.986] |
| 2 | Deep learning model SOTA frontier | 0.96 | 2022-01-01 | aggregation=study-level; average of slice predictions · Binary race classification; study-level score aggregated by averaging slice predictio… | AI recognition of patient race in medical imaging: a modelling studySource quote0.92 (slice), 0.96 (study) |
| 3 | PARE (ensemble of multiple deep supervision heads) (+1 variant) | 0.931 | 2023-07-01 | variant=ensemble of multiple deep supervision heads · Overall AUC; ensemble of multiple deep supervision heads. | Parse and Recall: Towards Accurate Lung Nodule Malignancy Prediction Like RadiologistsSource quoteMoreover, by utilizing the ensemble of multiple deep supervision heads, the overall AUC is further improved to 0.931 on both datasets. |
| 4 | Tri2D-Net SOTA frontier (+1 variant) | 0.871 | 2020-08-01 | input=low-dose-CT · test_subjects=2085 · CVD risk prediction; separate subject-level test set of 2,085 subjects. The model was… | Deep Learning Predicts Cardiovascular Disease Risks from Lung Cancer Screening Low Dose Computed TomographySource quoteCancer patients have a higher risk of cardiovascular disease (CVD) mortality than the general population. Low dose computed tomography (LDCT) for lung cancer screening offers an opportunity for simultaneous CVD risk estimation in at-risk patients. Our deep learning CVD risk prediction model, trained with 30,286 LDCTs from the National Lung Cancer Screening Trial, achieved an area under the curve (AUC) of 0.871 on a separate test set of 2,085 subjects and identified patients with high CVD mortality risks (AUC of 0.768). We validated our model against ECG-gated cardiac CT based markers, including coronary artery calcification (CAC) score, CAD-RADS score, and MESA 10-year risk score from an independent dataset of 335 subjects. Our work shows that, in high-risk patients, deep learning can convert LDCT for lung cancer screening into a dual-screening quantitative tool for CVD risk estimation. |
| 5 | AdaFuse (+1 variant) | 0.762 | 2026-01-01 | Held-out test set (462 patients); binary prediction of lung cancer diagnosis during u… | AdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement LearningSource quoteAdaFuse (Ours) │ 0.762 │ [0.657, 0.860] |
| 6 | 3D Res18 (+1 variant) | 0.69 | 2025-01-01 | input=most-recent CT · sample-size=1882 · nodule-crops=top-five · NLST real-data experiment (paper reports n=1,882); most-recent CT input, top-five sus… | Improving lung cancer diagnosis and survival prediction with deep learning and CT imagingSource quote3D Res18 │ 0.690 │ 0.601 |
Showing 3 of 3 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | Multipath cycleGAN proposed | median percent emphysema | 10.13% | method=Multipath cycleGAN · source-kernel=Philips D · target-kernel=Siemens B30f | Multipath cycleGAN for harmonization of paired and unpaired low-dose lung computed tomography reconstruction kernelsSource quoteL160: GE STANDARD and GE LUNG but overcorrected Philips D (median 10.13%) and Philips C (9.13%). |
| 2025 | Multipath cycleGAN proposed | median percent emphysema | 9.13% | method=Multipath cycleGAN · source-kernel=Philips C · target-kernel=Siemens B30f | Multipath cycleGAN for harmonization of paired and unpaired low-dose lung computed tomography reconstruction kernelsSource quoteL160: GE STANDARD and GE LUNG but overcorrected Philips D (median 10.13%) and Philips C (9.13%). |
| 2025 | Siemens B30f reference kernel baseline | median percent emphysema | 6.60% | reference-kernel=Siemens B30f | Multipath cycleGAN for harmonization of paired and unpaired low-dose lung computed tomography reconstruction kernelsSource quoteL155: We visualize the emphysema distributions before and after harmonization using boxplots overlaid with strip plots as seen in Figure 5. We represent all measurements as the median emphysema measurements. The reference Siemens B30f kernel, had a median of 6.60%. |