NLST
21 papers · 59 extracted observations · sinogram standardization · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | 3D-morphomics+Radiomics SOTA frontier (+2 variants) | 0.978 | 2022-07-01 | Model trained on the NLST train-validation set and evaluated on the NLST test set. | 3D-Morphomics, Morphological Features on CT scans for lung nodule malignancy diagnosisSource quote3D-morphomics+Radiomics (NLST) │ 0.978 │ 92.7 │ 94.7 │ 0.95 │ 0.979±0.004[0.971 0.986] |
| 2 | Deep learning model SOTA frontier | 0.96 | 2022-01-01 | aggregation=study-level; average of slice predictions · Binary race classification; study-level score aggregated by averaging slice predictio… | AI recognition of patient race in medical imaging: a modelling studySource quote0.92 (slice), 0.96 (study) |
| 3 | PARE (ensemble of multiple deep supervision heads) (+1 variant) | 0.931 | 2023-07-01 | variant=ensemble of multiple deep supervision heads · Overall AUC; ensemble of multiple deep supervision heads. | Parse and Recall: Towards Accurate Lung Nodule Malignancy Prediction Like RadiologistsSource quoteMoreover, by utilizing the ensemble of multiple deep supervision heads, the overall AUC is further improved to 0.931 on both datasets. |
| 4 | Tri2D-Net SOTA frontier (+1 variant) | 0.871 | 2020-08-01 | input=low-dose-CT · test_subjects=2085 · CVD risk prediction; separate subject-level test set of 2,085 subjects. The model was… | Deep Learning Predicts Cardiovascular Disease Risks from Lung Cancer Screening Low Dose Computed TomographySource quoteCancer patients have a higher risk of cardiovascular disease (CVD) mortality than the general population. Low dose computed tomography (LDCT) for lung cancer screening offers an opportunity for simultaneous CVD risk estimation in at-risk patients. Our deep learning CVD risk prediction model, trained with 30,286 LDCTs from the National Lung Cancer Screening Trial, achieved an area under the curve (AUC) of 0.871 on a separate test set of 2,085 subjects and identified patients with high CVD mortality risks (AUC of 0.768). We validated our model against ECG-gated cardiac CT based markers, including coronary artery calcification (CAC) score, CAD-RADS score, and MESA 10-year risk score from an independent dataset of 335 subjects. Our work shows that, in high-risk patients, deep learning can convert LDCT for lung cancer screening into a dual-screening quantitative tool for CVD risk estimation. |
| 5 | AdaFuse (+1 variant) | 0.762 | 2026-01-01 | Held-out test set (462 patients); binary prediction of lung cancer diagnosis during u… | AdaFuse: Adaptive Multimodal Fusion for Lung Cancer Risk Prediction via Reinforcement LearningSource quoteAdaFuse (Ours) │ 0.762 │ [0.657, 0.860] |
| 6 | 3D Res18 (+1 variant) | 0.69 | 2025-01-01 | input=most-recent CT · sample-size=1882 · nodule-crops=top-five · NLST real-data experiment (paper reports n=1,882); most-recent CT input, top-five sus… | Improving lung cancer diagnosis and survival prediction with deep learning and CT imagingSource quote3D Res18 │ 0.690 │ 0.601 |
Showing 10 of 10 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Real baseline LDCT baseline | AUROC | 0.742 | timepoint=baseline · image-source=real LDCT | Nodule-Aligned Latent Space Learning with LLM-Driven Multimodal Diffusion for Lung Nodule Progression PredictionSource quoteL163: Real baseline LDCT │ 0.742 │ 0.263 |
| 2026 | Real follow-up LDCT baseline | AUROC | 0.819 | timepoint=follow-up · image-source=real LDCT | Nodule-Aligned Latent Space Learning with LLM-Driven Multimodal Diffusion for Lung Nodule Progression PredictionSource quoteL164: Real follow-up LDCT │ 0.819 │ 0.393 |
| 2025 | CT foundation model baseline | AUROC | 0.729 | prediction-horizon=2-year | Learning Contrastive Multimodal Fusion with Improved Modality Dropout for Disease Detection and PredictionSource quoteL175: CT foundation model \cite{yang_advancing_2024} │ 0.729 │ 0.070 │ 0.956 │ 0.700 │ 0.050 │ 0.972 |
| 2025 | CT foundation model baseline | AUROC | 0.700 | prediction-horizon=1-year | Learning Contrastive Multimodal Fusion with Improved Modality Dropout for Disease Detection and PredictionSource quoteL175: CT foundation model \cite{yang_advancing_2024} │ 0.729 │ 0.070 │ 0.956 │ 0.700 │ 0.050 │ 0.972 |
| 2025 | RAD-DINO baseline | patient-level ROC-AUC | 0.646 | split: test · head=MLP · input=raw · encoder=frozen · pooling=mean | Virtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk PredictionSource quoteL163: RAD-DINO │ 0.646 vs.\ 0.683 │ < 0.004 |
| 2025 | RAD-DINO baseline | patient-level ROC-AUC | 0.683 | split: test · head=MLP · input=Virtual-Eyes-preprocessed · encoder=frozen · pooling=mean | Virtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk PredictionSource quoteL163: RAD-DINO │ 0.646 vs.\ 0.683 │ < 0.004 |
| 2025 | Sybil baseline | patient-level ROC-AUC | 0.886 | split: test · input=raw · pooling=mean · backbone_retrained=false | Virtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk PredictionSource quoteL164: Sybil │ 0.886 vs.\ 0.837 │ 0.021 |
| 2025 | Sybil baseline | patient-level ROC-AUC | 0.837 | split: test · input=Virtual-Eyes-preprocessed · pooling=mean · backbone_retrained=false | Virtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk PredictionSource quoteL164: Sybil │ 0.886 vs.\ 0.837 │ 0.021 |
| 2025 | ResNet-18 baseline | patient-level ROC-AUC | 0.571 | split: test · input=raw · pooling=mean · backbone=ResNet-18 · backbone_retrained=false | Virtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk PredictionSource quoteL165: ResNet-18 │ 0.571 vs.\ 0.596 │ 0.043 |
| 2025 | ResNet-18 baseline | patient-level ROC-AUC | 0.596 | split: test · input=Virtual-Eyes-preprocessed · pooling=mean · backbone=ResNet-18 · backbone_retrained=false | Virtual-Eyes: Quantitative Validation of a Lung CT Quality-Control Pipeline for Foundation-Model Cancer Risk PredictionSource quoteL165: ResNet-18 │ 0.571 vs.\ 0.596 │ 0.043 |