MIMIC-IV

123 papers · 397 extracted observations · mortality prediction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.70.70.80.8202420252027MEDS-Tab: 0.811 (2024)Fair model g-\theta (fair): 0.723 (2024)Performance-optimized predictive model g-\theta (lg): 0.746 (2024)GAT-guided agent-discovered expression: 0.676 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 150 of 397 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026StAR proposedCI width2.021subset=Medical ICU · F-statistic=5.66 · sample-size=n=21,762 · confidence-level=95%Adaptive Inference with Weak Instruments
Source quote
L704: 2.021
2026Qwen3-4B (Mech) proposedMacro-F10.51params=4B · backbone=Qwen3-4BCharacterize Then Distill: Mechanistic Reasoning in Large Output Spaces
Source quote
L997: \gain{0.51}{0.12}
2026MIMIC-IV multimodal pipeline proposedRuntime (clock time)2,430.44 secondshardware=Intel Core i7; 16 GB DDR4 RAM; Windows 11 · modalities=notes+x-ray · sample-size=100A Multimodal Data Processing Pipeline for MIMIC-IV Dataset
Source quote
L212: Integrated Modalities │ Runtime Notes + X-ray (n:100) │ 2,430.44
2026MIMIC-IV multimodal pipeline proposedRuntime (clock time)2,479.06 secondshardware=Intel Core i7; 16 GB DDR4 RAM; Windows 11 · modalities=notes+waveforms · sample-size=100A Multimodal Data Processing Pipeline for MIMIC-IV Dataset
Source quote
L213: Notes + Waveforms (n:100) │ 2,479.06
2026MIMIC-IV multimodal pipeline proposedRuntime (clock time)0.31 secondshardware=Intel Core i7; 16 GB DDR4 RAM; Windows 11 · modalities=waveforms · sample-size=50A Multimodal Data Processing Pipeline for MIMIC-IV Dataset
Source quote
L214: Waveforms (n:50) │ 0.31
2026MIMIC-IV multimodal pipeline proposedRuntime (clock time)300 secondshardware=Intel Core i7; 16 GB DDR4 RAM; Windows 11 · modalities=structured data+notes+waveforms · sample-size=200A Multimodal Data Processing Pipeline for MIMIC-IV Dataset
Source quote
L217: Structured + Notes + Waveforms (n:200) │ 300
2026MIMIC-IV multimodal pipeline proposedRuntime (clock time)2,735.85 secondshardware=Intel Core i7; 16 GB DDR4 RAM; Windows 11 · modalities=structured data+notes+waveforms+x-ray+2D echo · sample-size=200 per modalityA Multimodal Data Processing Pipeline for MIMIC-IV Dataset
Source quote
L218: Structured + Notes + Waveforms (n:200) + X-ray (n:200) + 2D Echo (n:200) │ 2,735.85
2026MedCoRAG proposedPrecision81.32%split: test · params=8B · subset=13 hepatic disease classes · teacher=Qwen3-Max · backbone=Llama-3.1-8B-InstructMedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty Consensus
Source quote
L285: MedCoRAG │ 81.32 │ 79.18 │ 79.12 │ 78.99
2026MedCoRAG proposedRecall79.18%split: test · params=8B · subset=13 hepatic disease classes · teacher=Qwen3-Max · backbone=Llama-3.1-8B-InstructMedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty Consensus
Source quote
L285: MedCoRAG │ 81.32 │ 79.18 │ 79.12 │ 78.99
2026MedCoRAG proposedF1-score79.12%split: test · params=8B · subset=13 hepatic disease classes · teacher=Qwen3-Max · backbone=Llama-3.1-8B-InstructMedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty Consensus
Source quote
L285: MedCoRAG │ 81.32 │ 79.18 │ 79.12 │ 78.99
2026MedCoRAG proposedF0.5-score78.99%split: test · params=8B · subset=13 hepatic disease classes · teacher=Qwen3-Max · backbone=Llama-3.1-8B-InstructMedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty Consensus
Source quote
L285: MedCoRAG │ 81.32 │ 79.18 │ 79.12 │ 78.99
2026TI-SAE (soft) proposedAOPC.130out-of-distributionTemporal Island Sparse Autoencoders for Interpreting Clinical Time-Series Models
Source quote
L531: .130
2026TI-SAE (soft) proposedAUROC.756out-of-distributionTemporal Island Sparse Autoencoders for Interpreting Clinical Time-Series Models
Source quote
L533: .756/.370
2026TI-SAE (soft) proposedAUPRC.370out-of-distributionTemporal Island Sparse Autoencoders for Interpreting Clinical Time-Series Models
Source quote
L533: .756/.370
2026Proposed TCF model (No Share) proposedPRC0.419features=195 · configuration=No ShareTime-Conditioned Foreseeing: An EHR-Specific Foundation Model for Irregular Dynamics and Calendrical Time
Source quote
L390: 0.419
2026TGTFULL proposedrace AUROC gap (max–min)0.1291Matched graph-structure ablation with identical data splits, seeds, and training settin…A Controlled Study of Fairness Interventions for Temporal Graph Transformers on ICU Mortality Prediction
Source quote
L181: Under matched training (Figure 5), TGTFULL is comparable to LSTM in overall AUROC (0.8328 vs. 0.8281) but has a smaller race AUROC gap (0.1291 vs. 0.1352). Decomposing the change in race gap relative to LSTM, TGTTEMPORAL increases the race gap by +0.0297 while TGTCLINICAL decreases it by −0.005; we present this only as a difference relative to LSTM, not as a formal causal attribution. The pattern is consistent with the hypothesis that clinical-similarity edges encode lag relationships that are less correlated with demographic features than raw temporal adjacency, but our experiments do not establish a causal mechanism.
2026Curve-NECA (NECA-augmented predictor) proposed non-standard slicePR-AUC0.520split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L667: 0.520
2026Curve-NECA (NECA-augmented predictor) proposed non-standard slicePR-AUC0.345split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L672: 0.345
2026Curve-NECA (NECA-augmented predictor) proposed non-standard slicePR-AUC0.357split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L677: 0.357
2026Curve-NECA (NECA-augmented predictor) proposed non-standard slicePR-AUC0.289split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L682: 0.289
2026Curve-NECA (NECA-augmented predictor) proposed non-standard sliceROC-AUC0.809split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L669: 0.809
2026Curve-NECA (NECA-augmented predictor) proposed non-standard sliceROC-AUC0.693split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L674: 0.693
2026Curve-NECA (NECA-augmented predictor) proposed non-standard sliceROC-AUC0.674split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L679: 0.674
2026Curve-NECA (NECA-augmented predictor) proposed non-standard sliceROC-AUC0.696split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L684: 0.696
2026Calibrated XGBoost (after age-matched resampling) proposedF1 score0.8108age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L480: prior to age-matched resampling, compared to a 0.8108 F1
2026Calibrated XGBoost (after age-matched resampling) proposedAUPRC0.8891age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L481: score and a 0.8891 AUPRC after age-matched resampling.
2026Calibrated XGBoost (age-matched, 20-seed average) proposedF1 score0.8062split: test · age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L671: fier achieved an average F1 score of 0.8062 with a 95% con-
2026GAT-guided agent-discovered expression proposedAUC0.676split: valAgentic discovery of blood biomarker from distilled private health records
Source quote
L421: 0.516 [0.501, 0.563] / 0.676 [0.633, 0.723]
2026COMBIO (MIMIC-IV mortality task) proposed non-standard sliceAUROC0.773split: testCOMBIO: Automated Discovery of a Compact Composite Biomarker from Routine Laboratory Panels
Source quote
L435: 0.773
2026COMBIO (MIMIC-IV sepsis case-finding task) proposed non-standard sliceAUROC0.781split: testCOMBIO: Automated Discovery of a Compact Composite Biomarker from Routine Laboratory Panels
Source quote
L448: 0.781
2026COMBIO (eICU-derived reverse-derivation in-hospital mortality score) proposedAUROC0.771split: externalCOMBIO: Automated Discovery of a Compact Composite Biomarker from Routine Laboratory Panels
Source quote
L728: 0.771
2026DRIFT proposedObserved-target MAP MAE gap (shifted minus recorded)0.554 mmHgsubset=windows where donor substitution changed at least one supplied future exposure · horizon=8-hour · intervention=future-only patient-action replacementDRIFT: Direct-Recursive Intervention-Conditioned Forecasting of ICU Physiological Trajectories
Source quote
L1476: 0.554
2026SparseEHR proposedRecall@100.4630-shot · code-system=ICD-10 · transfer-source=OLDW · prediction-horizon=next-visitSparseEHR: Scalable Foundation Modeling for Structured EHR via Conditional Computation
Source quote
L92: SparseEHR achieves 0.463 Recall@10 and 0.551 Recall@20 on MIMICIV in a zero-shot setting (Table 1). These values are higher than the published baselines we include for context, but the comparison should not be read as a protocol-matched state-of-the-art claim because cohort construction, mapping, and metric definitions may differ. The result instead suggests that large-scale structured-EHR pretraining can transfer across institutions when records are expressed in a common typed-token schema.
2026GenRxR proposedDDI ratio7.71Reported for admissions in the dataset; DDI ratio measures the proportion of predicted …Improving Rare Medication Recommendation with Counterfactual Data Augmentation and Large Language Models
Source quote
L456: In addition, GenRxR\xspace yields DDI ratios of 8.29 on MIMIC-\uppercase\expandafter{\romannumeral3}\xspace and 7.71 on MIMIC-\uppercase\expandafter{\romannumeral4}\xspace, which are close to those of the ground-truth prescriptions (8.26 and 7.89, respectively).
2026CF-Evolve (Ours; Qwen2.5-7B) proposedAUROC0.7553params=7B · backbone=Qwen2.5-7B · task-detail=in-hospital mortalityCounterfactual Self-Evolving Agents for Evidence-Grounded Reasoning
Source quote
L1233: \multirow{3}{*}{MIMIC-IV / IHM} │ \multirow{3}{*}{AUROC} │ Qwen2.5-7B │ 0.7000 │ -- │ -- │ 0.7235 │ 0.7553
2026OPL-MT-MNAR proposedFitted Q-Evaluation (FQE)0.634split: test · modalities=low-frequency radiology and microbiology diagnostic text · decision-step=4-hour · observation-window=72-hourLearning Dynamic Representations and Policies from Multimodal Clinical Time-Series with Informative Missingness
Source quote
L306: As shown in Table~\ref{tab:main_results}, the OPL-MT-MNAR policy reaches FQE 0.679 on MIMIC-III, compared with clinician behavior at 0.528. The gain also persists on the complementary benchmarks, reaching 0.634 on MIMIC-IV versus 0.521 for clinician behavior and 0.604 on eICU versus 0.534.
2026Info-Resolution Scaling Law (vocabulary-based ρ estimator) proposedRefitted target data-scaling exponent β0.298rho-estimator=vocabulary-based · source-corpus=OpenWebTextOn the Invariance and Generality of Neural Scaling Laws
Source quote
L508: \hat{\beta}_t │ refitted │ 0.298 │ 0.319 │ 0.321 │ 0.325
2026Info-Resolution Scaling Law (3-gram ρ estimator) proposedRefitted target data-scaling exponent β0.319rho-estimator=3-gram entropy · source-corpus=OpenWebTextOn the Invariance and Generality of Neural Scaling Laws
Source quote
L508: \hat{\beta}_t │ refitted │ 0.298 │ 0.319 │ 0.321 │ 0.325
2026Info-Resolution Scaling Law (compression-based ρ estimator) proposedRefitted target data-scaling exponent β0.321rho-estimator=gzip compression · source-corpus=OpenWebTextOn the Invariance and Generality of Neural Scaling Laws
Source quote
L508: \hat{\beta}_t │ refitted │ 0.298 │ 0.319 │ 0.321 │ 0.325
2026Info-Resolution Scaling Law proposedRefitted data-scaling exponent β0.251noise-injection=rho(T)=0.5On the Invariance and Generality of Neural Scaling Laws
Source quote
L547: \hat{\beta}_t │ refitted │ 0.251 │ 0.244
2026Patients-like-me (PLM), VEM, Meerkat-8B proposedAUPRC49.7params=8B · backbone=Meerkat-8B · prediction-window=15-dayPatients-like-me: A Variational LM--GNN Framework for Explainable Clinical Prediction
Source quote
L1179: 49.7 │ 80.3 │ 85.3 │ 35.6 │ 77.1 │ 65.7 │ 50.4
2026Patients-like-me (PLM), VEM, Meerkat-8B proposedJaccard50.4params=8B · backbone=Meerkat-8BPatients-like-me: A Variational LM--GNN Framework for Explainable Clinical Prediction
Source quote
L1179: 49.7 │ 80.3 │ 85.3 │ 35.6 │ 77.1 │ 65.7 │ 50.4
2026Patients-like-me (PLM), VEM, Meerkat-8B proposedTraining time per epoch2.55 hours per epochparams=8B · backbone=Meerkat-8B · measurement=training-time-per-epochPatients-like-me: A Variational LM--GNN Framework for Explainable Clinical Prediction
Source quote
L1204: VEM │ 2.55 │ 80.4 │ 77.1 │ 65.7 │ 50.4
2026Full Hybrid (proposed neuro-symbolic reasoning framework) proposedTop-1 Accuracy57.2%version=3.1 · label-regime=multi-labelUncertainty Reasoning with Large Language Models for Explainable Disease Diagnosis
Source quote
L453: Full Hybrid │ 57.2 │ 45.6 │ 50.7 │ 76.3 │ 38.2 │ 64.4 │ 48.0 │ 89.3 │ 25.0 │ 75.5 │ 37.6
2026ViSTA-Joint (full V+R) proposedAP0.4650params=4B · backbone=4BViSTA: A Simple Bridge Extends Visual Alignment to Clinical Time-Series Understanding in Multimodal LLMs
Source quote
L435: \textbf{\texttt{ViSTA}\xspace{}: full V+R} │ 0.7440 │ 0.4650 │ 0.7350 │ 0.2651 │ 41.73
2026ViSTA-Joint (full V+R) proposedAP0.2651params=4B · backbone=4BViSTA: A Simple Bridge Extends Visual Alignment to Clinical Time-Series Understanding in Multimodal LLMs
Source quote
L435: \textbf{\texttt{ViSTA}\xspace{}: full V+R} │ 0.7440 │ 0.4650 │ 0.7350 │ 0.2651 │ 41.73
2026ViSTA proposedAUROC0.7376params=2B · trainable-params=0.516MViSTA: A Simple Bridge Extends Visual Alignment to Clinical Time-Series Understanding in Multimodal LLMs
Source quote
L4: Clinical prediction models estimate risk from patient measurements, while large language models support medical text understanding and question answering. Yet their language capabilities do not ensure accurate prediction from structured, high-dimensional clinical time series. Improving this ability would connect risk estimation with flexible questions about a patient's evolving condition. We introduce \texttt{ViSTA}\xspace{}, a compact adapter that incorporates irregular numerical measurements into a pretrained vision-language model's chart representations. It learns corrections to visual tokens while leaving all pretrained parameters unchanged. On MIMIC-IV, \texttt{ViSTA}\xspace{} has the highest mean scores among the compared adaptations on all four metrics for acute kidney injury and mortality prediction across models with 2-9 billion parameters. With 0.516 million trainable parameters, the 2-billion-parameter model reaches an area under the ROC curve of 0.7376 for acute kidney injury, compared with GPT-5.6 Sol's 0.7380 with text input and high reasoning effort. Training for temporal question answering yields 69.27% accuracy at 4 billion parameters with over 90% fewer trainable parameters than low-rank adaptation using charts or numerical text, at a 2.82-4.88 percentage-point accuracy gap. \texttt{ViSTA}\xspace{} extends pretrained language models to numerical prediction and temporal questions.
2026PATH (Gemma 4B) proposedTDCR (JSD; lower is better)0.2886params=4B · epsilon=2.0 · backbone=Gemma 4B · generation-unit=user-level trajectoriesPrivately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular Data
Source quote
L561: Gemma 4B (\varepsilon=2.0) │ 0.661 │ 0.2886 │ 3.2980 │ 0.3867
2026PATH (Gemma 4B) proposedState transition divergence (average Frobenius norm; lower is better)0.3867params=4B · epsilon=2.0 · backbone=Gemma 4B · generation-unit=user-level trajectoriesPrivately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular Data
Source quote
L561: Gemma 4B (\varepsilon=2.0) │ 0.661 │ 0.2886 │ 3.2980 │ 0.3867
2026PATH (Gemma 4B) proposedMAUVE (Gecko; higher is better)0.651params=4B · epsilon=10.0 · backbone=Gemma 4B · embedding-model=GeckoPrivately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular Data
Source quote
L571: Gemma 4B (\varepsilon=10.0) │ 0.651 │ 0.3784 │ 3.4125 │ 0.3747
2026Tree-of-Evidence (ToE) proposedAUROC0.800split: test · 0-shot · params=109M · evidence-budget=k=5Tree-of-Evidence: Efficient "System 2" Search for Faithful Multimodal Grounding
Source quote
L248: We compare against 10 open-source (M)LLMs (1B–70B parameters), including medical fine-tunes and vision-language models, evaluated on E1 via zero-shot prompting with the full test set. Table~\ref{tab:llm} reports a representative subset; full results are in Appendix~\ref{app:llm_full}; Figure~\ref{fig:llm}. Even the strongest model, Med42-v2-70B (AUROC of 0.745), underperforms ToE at k = 5 (AUROC of 0.800) despite having 640× more parameters. Vision-language models (Gemma-2-12B (V), MedGemma-27B (V)~\cite{team2024gemma}) underperform their text-only counterparts on this task, suggesting that current Multimodal Large Language Models (MLLMs) struggle to extract discriminative signals from raw clinical images for structured prediction.
2026PACE-RAG + population prior proposedJaccard0.237split: test · backbone=GPT-4o-mini · split_method=patient-level · test_admissions=1004Tabular Population Priors as Structured Retrieval for EHR Medication Set Prediction
Source quote
L82: PACE-RAG + prior population prior 0.338 ± 0.017 0.237 admission with current diagnosis strings, observed medication classes, and a patient identifier used to construct chronological prior-admission history. The split is patient-level:
2026PACE-RAG proposedJaccard0.218split: test · backbone=GPT-4o-mini · retrieval=FAISS patient records · split_method=patient-level · test_admissions=1004Tabular Population Priors as Structured Retrieval for EHR Medication Set Prediction
Source quote
L81: 0.303 ± 0.018 0.218
2026MSAM proposedJaccard0.503inputs=diagnoses and procedures · patient-subset=at least two visits · medication-restrictions=with molecular restrictionsLearning Collective Medication Effects via Multi-level Abstraction for Medication Recommendation
Source quote
L322: MSAM │ 0.502/0.503 │ 0.762/0.762 │ 0.657/0.659
2026MSAM proposedF10.659inputs=diagnoses and procedures · patient-subset=at least two visits · medication-restrictions=with molecular restrictionsLearning Collective Medication Effects via Multi-level Abstraction for Medication Recommendation
Source quote
L322: MSAM │ 0.502/0.503 │ 0.762/0.762 │ 0.657/0.659
2026STAR-Set Transformer (joint-bias vtb-vtb schedule) proposedAUC0.7158bias-schedule=joint-bias vtb-vtb · encoder-layers=4Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time Series
Source quote
L4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models.
2026STAR-Set Transformer (joint-bias vtb-vtb schedule) proposedAPR0.0026bias-schedule=joint-bias vtb-vtb · encoder-layers=4Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time Series
Source quote
L4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models.
2026STAR-Set Transformer (joint-bias vtb-vtb schedule) proposedAUC0.9164bias-schedule=joint-bias vtb-vtb · encoder-layers=4Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time Series
Source quote
L4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models.
2026STAR-Set Transformer (joint-bias vtb-vtb schedule) proposedAPR0.2033bias-schedule=joint-bias vtb-vtb · encoder-layers=4Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time Series
Source quote
L4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models.
2026STAR-Set Transformer (joint-bias vtb-vtb schedule) proposedAUC0.8373bias-schedule=joint-bias vtb-vtb · encoder-layers=4Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time Series
Source quote
L4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models.
2026STAR-Set Transformer (joint-bias vtb-vtb schedule) proposedAPR0.1258bias-schedule=joint-bias vtb-vtb · encoder-layers=4Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time Series
Source quote
L4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models.
2026FC-TPP proposedMMD0.32missingness=initial-stageForward-Chaining Temporal Point Process
Source quote
L657: To evaluate robustness under incomplete observations, we simulate realistic missing-event patterns by removing events from four temporal segments: initial, early-middle, late-middle, and final stages. As shown in Fig. 5, FC-TPP outperforms all baselines in different missingness regimes. Performance degradation is most pronounced when early events are missing—an expected limitation for autoregressive models that rely on initial context—but FC-TPP still maintains reasonable quality (MMD = 0.32). In contrast, it achieves the best performance when middle or late-stage events are missing, highlighting its robustness for generation from partial and incomplete histories.
2026LLM-as-RNN (backbone unspecified) proposedAcc@10.6434LLM-judged semantic accuracy; compared in the text with the best MemPrompt variant, who…LLM-as-RNN: A Recurrent Language Model for Memory Updates and Sequence Prediction
Source quote
L251: The advantage is largest in settings where the ground truth changes over time or conflicts with earlier evidence. On MIMIC-IV, where a patient’s condition can change abruptly, LLM-as-RNN improves Acc@1 by 12.6% (absolute) compared to the best MemPrompt variant (0.6434 vs. 0.5175). Similarly, on S\ │ P 500, where shifts in market regimes invalidate prior “trends,” our method lowers MSE by roughly 6.6% (3.821 vs. 4.090). These results suggest that standard append-only methods (FHC and MemPrompt) are prone to error persistence: once an incorrect diagnosis or outdated sentiment is written into the context, it continues to bias future predictions. In contrast, LLM-as-RNN can actively “forget” or revise these obsolete patterns through its update mechanism.
2026LLM-as-RNN (Llama-3-70B) proposedAcc@10.5804params=70B · backbone=Llama-3-70BLLM-as-RNN: A Recurrent Language Model for Memory Updates and Sequence Prediction
Source quote
L253: A direct comparison between LLM-as-RNN and FHC underscores the inefficiency of raw context. Although FHC receives a complete, lossless history, it consistently underperforms our compressed-state approach (e.g., for Llama-3-70B, FHC Acc@1 is 0.4126 vs. 0.5804 for LLM-as-RNN). This indicates that the bottleneck in sequential prediction is not how much information is available, but how well that information is curated. FHC is vulnerable to attention dilution and noise, whereas LLM-as-RNN acts as an information filter that preserves only the signals relevant for the next prediction.
2026GLEAN +Active proposedAUROC0.9345params=7B · backbone=Qwen2.5-7B-Instruct · generation-budget=N=16 · active-verification-threshold=εu=0.5Guideline-Grounded Evidence Accumulation for High-Stakes Agent Verification
Source quote
L577: +Active (\epsilon_u=0.5) │ O(T\cdot K) │ 20.3 │ 132.7 │ 0.9345 │ 0.0992 \\[1.5pt]
2026GLEAN +Active proposedBrier0.0992params=7B · backbone=Qwen2.5-7B-Instruct · generation-budget=N=16 · active-verification-threshold=εu=0.5Guideline-Grounded Evidence Accumulation for High-Stakes Agent Verification
Source quote
L577: +Active (\epsilon_u=0.5) │ O(T\cdot K) │ 20.3 │ 132.7 │ 0.9345 │ 0.0992 \\[1.5pt]
2026LONGINUS proposedMicro-F1.597training-freeRethinking Next-Visit Diagnosis Prediction Beyond Aggregate Metrics: Retrieval--Memory Multi-Agent Adjudication
Source quote
L1233: .597†
2026LONGINUS (Gemini-3.1-Flash-Lite) proposedMicro-F1.583training-freeRethinking Next-Visit Diagnosis Prediction Beyond Aggregate Metrics: Retrieval--Memory Multi-Agent Adjudication
Source quote
L1259: margins are smaller in aggregate metrics (e.g., .583
2026MM-KG (condition D) proposedAUROC.72All 3,200 MIMIC join items; condition D supplies both patient modalities and KG relatio…Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L578: 0.651 (.72)
2026MM-KG (condition D) proposedHits@10.575split: held-outAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L707: 0.575
2026MM-KG full model (trained GNN) proposedAUROC0.804split: test · trainedAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L869: alone, and the trained GNN reaches 0.804, against 0.778 for a laboratory-only model; laboratory values
2026MM-KG full model (identity-hard subset) proposed non-standard sliceHits@10.582split: held-outAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L709: 0.582
2026MDS-ICU (S4+RealMLP multimodal) proposedAUROC0.90ecg=10-second 12-lead · modalities=ECG and clinical data · prediction-horizon=24-hourA Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician Benchmarking
Source quote
L4: Artificial intelligence (AI) holds substantial promise for supporting clinical decision-making in intensive care units (ICUs), where timely and accurate risk assessment is essential. However, many existing predictive models remain narrowly scoped, focusing on isolated outcomes or limited data modalities, whereas clinicians routinely synthesize longitudinal clinical history, real-time physiological signals, and heterogeneous diagnostic information when assessing patient risk. To address this gap, we developed MDS-ICU, a unified multimodal machine learning framework that fuses routinely collected patient data—including demographics, biometrics, vital signs, laboratory values, ECG waveforms, surgical procedures, and medical device usage—to provide comprehensive predictive support throughout ICU stays. Using data from 63,001 samples across 27,062 patients in MIMIC-IV, we trained a deep learning architecture combining structured state-space (S4) encoders for ECG waveforms with multilayer perceptron (RealMLP) encoders for tabular features to jointly predict 33 clinically relevant outcomes spanning mortality, organ dysfunction, medication requirements, and acute deterioration events. The framework demonstrated strong discriminative performance, achieving AUROCs of 0.90 for 24-hour mortality, 0.92 for sedative administration, 0.97 for invasive mechanical ventilation, and 0.93 for coagulation dysfunction. Calibration analyses showed close alignment between predicted probabilities and observed outcomes, with ECG waveform inclusion yielding consistent improvements in both discrimination and predictive reliability. Direct comparison with clinicians and LLMs showed that model predictions alone outperformed clinicians' judgment and LLM predictions. Furthermore, providing model outputs as augmented decision support further increased predictive accuracy of both clinicians and LLMs. These results demonstrate that multimodal AI frameworks can deliver continuous, clinically meaningful risk stratification across diverse ICU outcomes while empirically showing that AI augments—rather than replaces—clinical expertise. This work establishes a scalable foundation for the integration of high-frequency physiological data into precision-oriented critical care decision support.
2026MDS-ICU (S4+RealMLP multimodal) proposedAUROC0.92ecg=10-second 12-lead · modalities=ECG and clinical data · prediction-horizon=24-hourA Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician Benchmarking
Source quote
L4: Artificial intelligence (AI) holds substantial promise for supporting clinical decision-making in intensive care units (ICUs), where timely and accurate risk assessment is essential. However, many existing predictive models remain narrowly scoped, focusing on isolated outcomes or limited data modalities, whereas clinicians routinely synthesize longitudinal clinical history, real-time physiological signals, and heterogeneous diagnostic information when assessing patient risk. To address this gap, we developed MDS-ICU, a unified multimodal machine learning framework that fuses routinely collected patient data—including demographics, biometrics, vital signs, laboratory values, ECG waveforms, surgical procedures, and medical device usage—to provide comprehensive predictive support throughout ICU stays. Using data from 63,001 samples across 27,062 patients in MIMIC-IV, we trained a deep learning architecture combining structured state-space (S4) encoders for ECG waveforms with multilayer perceptron (RealMLP) encoders for tabular features to jointly predict 33 clinically relevant outcomes spanning mortality, organ dysfunction, medication requirements, and acute deterioration events. The framework demonstrated strong discriminative performance, achieving AUROCs of 0.90 for 24-hour mortality, 0.92 for sedative administration, 0.97 for invasive mechanical ventilation, and 0.93 for coagulation dysfunction. Calibration analyses showed close alignment between predicted probabilities and observed outcomes, with ECG waveform inclusion yielding consistent improvements in both discrimination and predictive reliability. Direct comparison with clinicians and LLMs showed that model predictions alone outperformed clinicians' judgment and LLM predictions. Furthermore, providing model outputs as augmented decision support further increased predictive accuracy of both clinicians and LLMs. These results demonstrate that multimodal AI frameworks can deliver continuous, clinically meaningful risk stratification across diverse ICU outcomes while empirically showing that AI augments—rather than replaces—clinical expertise. This work establishes a scalable foundation for the integration of high-frequency physiological data into precision-oriented critical care decision support.
2026MDS-ICU (S4+RealMLP multimodal) proposedAUROC0.97ecg=10-second 12-lead · modalities=ECG and clinical dataA Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician Benchmarking
Source quote
L4: Artificial intelligence (AI) holds substantial promise for supporting clinical decision-making in intensive care units (ICUs), where timely and accurate risk assessment is essential. However, many existing predictive models remain narrowly scoped, focusing on isolated outcomes or limited data modalities, whereas clinicians routinely synthesize longitudinal clinical history, real-time physiological signals, and heterogeneous diagnostic information when assessing patient risk. To address this gap, we developed MDS-ICU, a unified multimodal machine learning framework that fuses routinely collected patient data—including demographics, biometrics, vital signs, laboratory values, ECG waveforms, surgical procedures, and medical device usage—to provide comprehensive predictive support throughout ICU stays. Using data from 63,001 samples across 27,062 patients in MIMIC-IV, we trained a deep learning architecture combining structured state-space (S4) encoders for ECG waveforms with multilayer perceptron (RealMLP) encoders for tabular features to jointly predict 33 clinically relevant outcomes spanning mortality, organ dysfunction, medication requirements, and acute deterioration events. The framework demonstrated strong discriminative performance, achieving AUROCs of 0.90 for 24-hour mortality, 0.92 for sedative administration, 0.97 for invasive mechanical ventilation, and 0.93 for coagulation dysfunction. Calibration analyses showed close alignment between predicted probabilities and observed outcomes, with ECG waveform inclusion yielding consistent improvements in both discrimination and predictive reliability. Direct comparison with clinicians and LLMs showed that model predictions alone outperformed clinicians' judgment and LLM predictions. Furthermore, providing model outputs as augmented decision support further increased predictive accuracy of both clinicians and LLMs. These results demonstrate that multimodal AI frameworks can deliver continuous, clinically meaningful risk stratification across diverse ICU outcomes while empirically showing that AI augments—rather than replaces—clinical expertise. This work establishes a scalable foundation for the integration of high-frequency physiological data into precision-oriented critical care decision support.
2026MDS-ICU (S4+RealMLP multimodal) proposedAUROC0.93ecg=10-second 12-lead · modalities=ECG and clinical dataA Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician Benchmarking
Source quote
L4: Artificial intelligence (AI) holds substantial promise for supporting clinical decision-making in intensive care units (ICUs), where timely and accurate risk assessment is essential. However, many existing predictive models remain narrowly scoped, focusing on isolated outcomes or limited data modalities, whereas clinicians routinely synthesize longitudinal clinical history, real-time physiological signals, and heterogeneous diagnostic information when assessing patient risk. To address this gap, we developed MDS-ICU, a unified multimodal machine learning framework that fuses routinely collected patient data—including demographics, biometrics, vital signs, laboratory values, ECG waveforms, surgical procedures, and medical device usage—to provide comprehensive predictive support throughout ICU stays. Using data from 63,001 samples across 27,062 patients in MIMIC-IV, we trained a deep learning architecture combining structured state-space (S4) encoders for ECG waveforms with multilayer perceptron (RealMLP) encoders for tabular features to jointly predict 33 clinically relevant outcomes spanning mortality, organ dysfunction, medication requirements, and acute deterioration events. The framework demonstrated strong discriminative performance, achieving AUROCs of 0.90 for 24-hour mortality, 0.92 for sedative administration, 0.97 for invasive mechanical ventilation, and 0.93 for coagulation dysfunction. Calibration analyses showed close alignment between predicted probabilities and observed outcomes, with ECG waveform inclusion yielding consistent improvements in both discrimination and predictive reliability. Direct comparison with clinicians and LLMs showed that model predictions alone outperformed clinicians' judgment and LLM predictions. Furthermore, providing model outputs as augmented decision support further increased predictive accuracy of both clinicians and LLMs. These results demonstrate that multimodal AI frameworks can deliver continuous, clinically meaningful risk stratification across diverse ICU outcomes while empirically showing that AI augments—rather than replaces—clinical expertise. This work establishes a scalable foundation for the integration of high-frequency physiological data into precision-oriented critical care decision support.
2026MDS-ICU (S4+RealMLP multimodal) proposedMacro-averaged AUROC0.865ecg=10-second 12-lead · outcomes=33 · tabular-features=801A Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician Benchmarking
Source quote
L16: \heading{Contributions} In this work, we introduce a generalist multimodal decision-support system for ICU care that integrates raw ECG waveforms with structured clinical data and explicitly benchmarks AI predictions against clinical judgment. Our contributions are threefold: (1) The construction and public release of a rich multimodal ICU dataset combining demographics, biometrics, vital sign and laboratory trends, surgical procedures, medical device usage, and raw ECG waveforms, together with 33 clinically meaningful deterioration targets spanning mortality, medication administration, organ dysfunction (Sepsis-3 SOFA), and acute clinical events. (2) A unified multimodal fusion framework that integrates high-frequency ECG waveforms with discrete clinical markers into a shared latent representation. This is achieved by combining statistical trend-based feature extraction for non-waveform time series, structured state-space models for ECG waveforms, and an enhanced deep tabular encoder. The architecture supports joint prediction across heterogeneous modalities, yielding high predictive performance (macro AUROC = 0.865) and strong calibration (Brier score = 0.0860). By comparison, the unimodal non-waveform model achieves 0.8583 AUROC and 0.0873 calibration, highlighting the added value of incorporating waveform information. (3) Clinician-centered benchmarks evaluating (i) clinician and LLM judgment versus model predictions where the proposed model outperforms both, and (ii) clinician/LLM judgment augmented with model outputs where on average, AI predictions increased the clinicians' predictive by a Youden index increase of 12% and LLM performance by 16%, demonstrating the model’s clinically meaningful benefit both alone and as augmented support. We envision this resource as both a clinically relevant benchmark and a foundation for reproducible research in ICU decision support. We refer to this dataset and framework as MDS-ICU (Multimodal Decision Support in the ICU).
2026TRACER (table label: Ours) proposedMacro F10.7942Readmission within 15 days after discharge; positive-label proportion 48.84%. Patients …Trajectory-Aware Clinical Risk Prediction via Severity-Grounded Knowledge Graphs and Retrieval-Augmented Generation
Source quote
L611: Ours │ 0.8938 │ 0.8830 │ 0.7722 │ 0.9688 │ 0.7949 │ 0.7942 │ 0.8752 │ 0.7183
2026Qwen3-8b (GES Opt; LLM-optimized GES features) proposedAUROC0.6537model=Qwen3-8b · params=8b · features=LLM-optimized GES causal features · outcomes=average across 7REACT-LLM: A Benchmark for Evaluating LLM Integration with Causal Features in Clinical Prognostic Tasks
Source quote
L402: 0.6537
2026Unified three-modality model (BioMedCLIP for CXR, CSFM for ECG, BioMedBERT for notes) proposedAUPRC0.43300-shot · modalities=EHR+CXR+ECG+clinical-notes · CXR-encoder=BioMedCLIP · ECG-encoder=CSFM · notes-encoder=BioMedBERT · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L116: \checkmark │ \checkmark │ \checkmark │ \checkmark │ Best per modality │ 0.8460 │ 0.4330 │ 0.6997
2026PACE-RAG proposedF1 score47.22%split: test · params=8B · backbone=Llama-3.1-8BPACE-RAG: Patient-Aware Contextual and Evidence-Constrained RAG for Clinical Drug Recommendation
Source quote
L22: Evaluated on a Parkinson’s cohort and the MIMIC-IV benchmark using Llama-3.1-8B and Qwen3-8B, PACE-RAG achieved state-of-the-art performance, reaching F1 scores of 80.84% and 47.22%, respectively.
2026EveryQuery proposedMean AUC (macro-averaged per-task AUROC)81.0%0-shotEveryQuery: Zero-Shot Clinical Prediction via Task-Conditioned Pretraining
Source quote
L96: 58.0% on AMC, all significantly above chance (Wilcoxon signed-rank p < 10−4). It achieves mean AUCs of 81.0%,
2026Factorization Machine (FM score) proposedDistance Correlation (dCorr)36.41Evaluated on the same evaluation split with the outcome-specific valid-label mask. Tabl…A Machine-Learned Comorbidity Index
Source quote
L2394: Factorization Machine (FM score) │ 36.41 │ 35.82 │ 50.80 │ 56.77 │ 31.96 │ 31.28 │ 45.38 │ 20.51
2026Learned projections proposedRecall@1033.6%MIMIC-IV; best-performing hyperparameters for each approach; evaluated by retrieving ev…Does Temporal Encoding Matter? Evidence from GRU-based Clinical Foundation Models
Source quote
L89: 33.6%
2026Learned projections proposedPrecision@1035.0%MIMIC-IV; best-performing hyperparameters for each approach; evaluated by retrieving ev…Does Temporal Encoding Matter? Evidence from GRU-based Clinical Foundation Models
Source quote
L90: 35.0%
2026MedCoRAG w/o MA (without Multi-Agent deliberation) ablationF1-score69.70%split: test · subset=13 hepatic disease classes · component=without Multi-Agent deliberationMedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty Consensus
Source quote
L345: w/o MA │ 76.30 │ 69.72 │ 69.70 │ 69.14
2026Patients-like-me (PLM), LM-only, Meerkat-8B ablationAUPRC43.9params=8B · backbone=Meerkat-8B · training-variant=LM-only · prediction-window=15-dayPatients-like-me: A Variational LM--GNN Framework for Explainable Clinical Prediction
Source quote
L1181: 43.9 │ 75.4 │ 79.1 │ 30.9 │ 71.3 │ 60.7 │ 45.8
2026Patients-like-me (PLM), LM-only, Meerkat-8B ablationJaccard45.8params=8B · backbone=Meerkat-8B · training-variant=LM-onlyPatients-like-me: A Variational LM--GNN Framework for Explainable Clinical Prediction
Source quote
L1181: 43.9 │ 75.4 │ 79.1 │ 30.9 │ 71.3 │ 60.7 │ 45.8
2026LM-only, Meerkat-8B ablationTraining time per epoch2.45 hours per epochparams=8B · backbone=Meerkat-8B · measurement=training-time-per-epoch · training-variant=LM-onlyPatients-like-me: A Variational LM--GNN Framework for Explainable Clinical Prediction
Source quote
L1208: LM-only │ 2.45 │ 76.8 │ 71.3 │ 60.7 │ 45.8
2026RealMLP unimodal non-waveform model ablationMacro-averaged AUROC0.8583modality=routine clinical data without ECG · outcomes=33A Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician Benchmarking
Source quote
L16: \heading{Contributions} In this work, we introduce a generalist multimodal decision-support system for ICU care that integrates raw ECG waveforms with structured clinical data and explicitly benchmarks AI predictions against clinical judgment. Our contributions are threefold: (1) The construction and public release of a rich multimodal ICU dataset combining demographics, biometrics, vital sign and laboratory trends, surgical procedures, medical device usage, and raw ECG waveforms, together with 33 clinically meaningful deterioration targets spanning mortality, medication administration, organ dysfunction (Sepsis-3 SOFA), and acute clinical events. (2) A unified multimodal fusion framework that integrates high-frequency ECG waveforms with discrete clinical markers into a shared latent representation. This is achieved by combining statistical trend-based feature extraction for non-waveform time series, structured state-space models for ECG waveforms, and an enhanced deep tabular encoder. The architecture supports joint prediction across heterogeneous modalities, yielding high predictive performance (macro AUROC = 0.865) and strong calibration (Brier score = 0.0860). By comparison, the unimodal non-waveform model achieves 0.8583 AUROC and 0.0873 calibration, highlighting the added value of incorporating waveform information. (3) Clinician-centered benchmarks evaluating (i) clinician and LLM judgment versus model predictions where the proposed model outperforms both, and (ii) clinician/LLM judgment augmented with model outputs where on average, AI predictions increased the clinicians' predictive by a Youden index increase of 12% and LLM performance by 16%, demonstrating the model’s clinically meaningful benefit both alone and as augmented support. We envision this resource as both a clinically relevant benchmark and a foundation for reproducible research in ICU decision support. We refer to this dataset and framework as MDS-ICU (Multimodal Decision Support in the ICU).
2026Learned latent compression (k=8, l=4) ablationAUPRC0.45990-shot · modalities=EHR+clinical-notes · compression=latent (k=8, l=4) · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L128: Table~\ref{tab:latent_compression} reports a compression ablation in a bimodal EHR + clinical notes model on ICU mortality. Mean pooling improves AUROC over no compression but slightly lowers AUPRC and F1, whereas best latent compression configuration improves all three. Sweeping k \in \{8, 16\} and l \in \{1, 2, 4\}, we select k{=}8, l{=}4, which gives the best AUPRC (0.4599) and competitive AUROC; we adopt it for all subsequent experiments. We note that no single setting dominates across all three metrics, so this choice prioritises AUPRC given the class imbalance of the mortality task.
2026Standard CPmaximum subgroup gap0.049Lower endpoint of the abstract-reported range 0.049–0.075; the cited text does not assi…Missingness-Aware Conformal Prediction Under Cross-Hospital Distribution Shift
Source quote
L6: on GOSSIS, standard CP attains 90% marginal coverage yet covers a low-missingness subgroup at only 0.775. We decompose the subgroup gap into a calibration heterogeneity term ηk and a within-group shift term δk, showing that the Mondrian bound removes ηk and is tighter when ηk exceeds the finite-sample grouping cost. We then introduce a label-free selection rule that chooses the missingness variable with the largest crosssite missingness shift and calibrates within its two subgroups. On GOSSIS, our method halves the maximum subgroup gap from 0.028–0.044 to 0.015–0.021 with less than 1% change in set size; on MIMIC-IV, it reduces the gap from 0.049–
2026Standard CPmaximum subgroup gap0.075Upper endpoint of the abstract-reported range 0.049–0.075; the cited text does not assi…Missingness-Aware Conformal Prediction Under Cross-Hospital Distribution Shift
Source quote
L7: 0.075 to 0.026–0.046. Subgroup assignment is invariant to model updates and remains stable under deployment-time stress tests where optimizationbased baselines degrade substantially.
2026Mondrian CP (missingness grouping)maximum subgroup gap0.026Lower endpoint of the abstract-reported range 0.026–0.046; the cited text does not assi…Missingness-Aware Conformal Prediction Under Cross-Hospital Distribution Shift
Source quote
L7: 0.075 to 0.026–0.046. Subgroup assignment is invariant to model updates and remains stable under deployment-time stress tests where optimizationbased baselines degrade substantially.
2026Anderson–Rubin (AR) baselineCI width4.870subset=Medical ICU · F-statistic=5.66 · sample-size=n=21,762 · confidence-level=95%Adaptive Inference with Weak Instruments
Source quote
L692: 4.870
2026DeepSeek-V3.1-Think baselineF1-score77.61%split: test · subset=13 hepatic disease classes · backbone=DeepSeek-V3.1-ThinkMedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty Consensus
Source quote
L267: DeepSeek-V3.1-Think \cite{deepseekai2024deepseekv3technicalreport} │ 79.59 │ 76.98 │ 77.61 │ 77.05
2026JEV (v1.14.0), Batch baselinemacro-F10.807split: testCan JEV Support Clinical Trial Criteria Assessment?
Source quote
L17: macro-F1 scores on TrialGPT (0.652 vs. 0.660) and MIMIC-IV (0.807 vs. 0.814), whereas
2026Qwen Flash, Batch baselinemacro-F10.814split: testCan JEV Support Clinical Trial Criteria Assessment?
Source quote
L17: macro-F1 scores on TrialGPT (0.652 vs. 0.660) and MIMIC-IV (0.807 vs. 0.814), whereas
2026JEV (v1.14.0), Single baselinemacro-F10.808split: testCan JEV Support Clinical Trial Criteria Assessment?
Source quote
L500: 0.808
2026Qwen Flash, Single baselinemacro-F10.732split: testCan JEV Support Clinical Trial Criteria Assessment?
Source quote
L514: 0.732
2026Attention baselineAOPC.097out-of-distributionTemporal Island Sparse Autoencoders for Interpreting Clinical Time-Series Models
Source quote
L536: .097
2026MOTOR baselinePRC0.385features=195 · configuration=No ShareTime-Conditioned Foreseeing: An EHR-Specific Foundation Model for Irregular Dynamics and Calendrical Time
Source quote
L389: 0.385
2026ETHOS baselineRMSE13426 minutesinterval bucket=0–1 · timestamp resolution=5 minutesTime-Conditioned Foreseeing: An EHR-Specific Foundation Model for Irregular Dynamics and Calendrical Time
Source quote
L746: 13426
2026LSTM baselinerace AUROC gap (max–min)0.1352Matched graph-structure ablation with identical data splits, seeds, and training settin…A Controlled Study of Fairness Interventions for Temporal Graph Transformers on ICU Mortality Prediction
Source quote
L181: Under matched training (Figure 5), TGTFULL is comparable to LSTM in overall AUROC (0.8328 vs. 0.8281) but has a smaller race AUROC gap (0.1291 vs. 0.1352). Decomposing the change in race gap relative to LSTM, TGTTEMPORAL increases the race gap by +0.0297 while TGTCLINICAL decreases it by −0.005; we present this only as a difference relative to LSTM, not as a formal causal attribution. The pattern is consistent with the hypothesis that clinical-similarity edges encode lag relationships that are less correlated with demographic features than raw temporal adjacency, but our experiments do not establish a causal mechanism.
2026Raw predictor (without NECA) baseline non-standard slicePR-AUC0.419split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L666: 0.419
2026Raw predictor (without NECA) baseline non-standard slicePR-AUC0.319split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L671: 0.319
2026Raw predictor (without NECA) baseline non-standard slicePR-AUC0.340split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L676: 0.340
2026Raw predictor (without NECA) baseline non-standard slicePR-AUC0.276split: testNECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration Prediction
Source quote
L681: 0.276
2026Logistic Regression (after age-matched resampling) baselineF1 score0.7816age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L444: 0.7816
2026Random Forest (after age-matched resampling) baselineF1 score0.7981age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L456: 0.7981
2026Logistic Regression (after age-matched resampling) baselineAUPRC0.8377age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L445: 0.8377
2026Random Forest (after age-matched resampling) baselineAUPRC0.8701age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L457: 0.8701
2026Literature-seeded starting expression baselineAUC0.516split: valAgentic discovery of blood biomarker from distilled private health records
Source quote
L421: 0.516 [0.501, 0.563] / 0.676 [0.633, 0.723]
2026Random Forest baselineF1-score (F1)0.645split: test · features=LACE-only (4 variables) · train-test-split=80/20From Prediction to Structure: Causal Discovery for 30-Day Readmission Prediction
Source quote
L72: 0.645
2026Random Forest baselineROC AUC (AUC)0.689split: test · features=LACE-only (4 variables) · train-test-split=80/20From Prediction to Structure: Causal Discovery for 30-Day Readmission Prediction
Source quote
L73: 0.689
2026Random Forest baselineF1-score (F1)0.836split: test · features=all 50 EHR features · train-test-split=80/20From Prediction to Structure: Causal Discovery for 30-Day Readmission Prediction
Source quote
L113: Forest achieves the strongest results with F1=0.836 and
2026Random Forest baselineROC AUC (AUC)0.907split: test · features=all 50 EHR features · train-test-split=80/20From Prediction to Structure: Causal Discovery for 30-Day Readmission Prediction
Source quote
L136: AUC=0.907, followed by CatBoost and XGBoost. These results show that richer EHR representations provide substantial predictive value beyond LACE alone, and that the predictive signal is robust across multiple non-linear models.
2026TFT-action baselineObserved-target MAP MAE gap (shifted minus recorded)0.300 mmHgsubset=windows where donor substitution changed at least one supplied future exposure · horizon=8-hour · intervention=future-only patient-action replacementDRIFT: Direct-Recursive Intervention-Conditioned Forecasting of ICU Physiological Trajectories
Source quote
L1477: 0.300
2026Qwen 2.5 7B baselineUnclear rate — pre-hospitalization functional status0.860 ratemodel=Qwen 2.5 7B · params=7B · questions=46 · sample_size=200 summariesCareTransition-Audit: A Benchmark to Audit Discharge Summaries for Efficient Care Transitions
Source quote
L68: Initial results highlight significant gaps in specific documentation areas. Table \ref{tab:unclear} lists the audit questions with the highest ambiguity. The most frequent \texttt{Unclear} element was pre-hospitalization functional status (rate of 0.860), followed by PCP contact information (0.680).
2026Qwen 2.5 7B baselineUnclear rate — PCP contact information0.680 ratemodel=Qwen 2.5 7B · params=7B · questions=46 · sample_size=200 summariesCareTransition-Audit: A Benchmark to Audit Discharge Summaries for Efficient Care Transitions
Source quote
L68: Initial results highlight significant gaps in specific documentation areas. Table \ref{tab:unclear} lists the audit questions with the highest ambiguity. The most frequent \texttt{Unclear} element was pre-hospitalization functional status (rate of 0.860), followed by PCP contact information (0.680).
2026Zero-shot (Qwen2.5-7B) baselineAUROC0.70000-shot · params=7B · backbone=Qwen2.5-7B · task-detail=in-hospital mortalityCounterfactual Self-Evolving Agents for Evidence-Grounded Reasoning
Source quote
L1233: \multirow{3}{*}{MIMIC-IV / IHM} │ \multirow{3}{*}{AUROC} │ Qwen2.5-7B │ 0.7000 │ -- │ -- │ 0.7235 │ 0.7553
2026Clinician behavior baselineFitted Q-Evaluation (FQE)0.521split: test · decision-step=4-hour · observation-window=72-hourLearning Dynamic Representations and Policies from Multimodal Clinical Time-Series with Informative Missingness
Source quote
L306: As shown in Table~\ref{tab:main_results}, the OPL-MT-MNAR policy reaches FQE 0.679 on MIMIC-III, compared with clinician behavior at 0.528. The gain also persists on the complementary benchmarks, reaching 0.634 on MIMIC-IV versus 0.521 for clinician behavior and 0.604 on eICU versus 0.534.
2026Target-domain ground-truth fit baseline non-standard sliceGround-truth target data-scaling exponent β0.325source-corpus=target-domain fitOn the Invariance and Generality of Neural Scaling Laws
Source quote
L508: \hat{\beta}_t │ refitted │ 0.298 │ 0.319 │ 0.321 │ 0.325
2026Ground-truth fit baseline non-standard sliceGround-truth data-scaling exponent β0.244noise-injection=rho(T)=0.5On the Invariance and Generality of Neural Scaling Laws
Source quote
L547: \hat{\beta}_t │ refitted │ 0.251 │ 0.244
2026GPT-4o baselineTop-1 Accuracy53.3%version=3.1 · label-regime=multi-labelUncertainty Reasoning with Large Language Models for Explainable Disease Diagnosis
Source quote
L452: GPT-4o │ 53.3 │ 42.0 │ 47.0 │ 75.3 │ 36.3 │ 63.5 │ 46.2 │ 88.4 │ 24.7 │ 76.2 │ 37.3
2026GPT-5.6 Sol baselineAUROC0.7380high-reasoning-effort · input=textViSTA: A Simple Bridge Extends Visual Alignment to Clinical Time-Series Understanding in Multimodal LLMs
Source quote
L4: Clinical prediction models estimate risk from patient measurements, while large language models support medical text understanding and question answering. Yet their language capabilities do not ensure accurate prediction from structured, high-dimensional clinical time series. Improving this ability would connect risk estimation with flexible questions about a patient's evolving condition. We introduce \texttt{ViSTA}\xspace{}, a compact adapter that incorporates irregular numerical measurements into a pretrained vision-language model's chart representations. It learns corrections to visual tokens while leaving all pretrained parameters unchanged. On MIMIC-IV, \texttt{ViSTA}\xspace{} has the highest mean scores among the compared adaptations on all four metrics for acute kidney injury and mortality prediction across models with 2-9 billion parameters. With 0.516 million trainable parameters, the 2-billion-parameter model reaches an area under the ROC curve of 0.7376 for acute kidney injury, compared with GPT-5.6 Sol's 0.7380 with text input and high reasoning effort. Training for temporal question answering yields 69.27% accuracy at 4 billion parameters with over 90% fewer trainable parameters than low-rank adaptation using charts or numerical text, at a 2.82-4.88 percentage-point accuracy gap. \texttt{ViSTA}\xspace{} extends pretrained language models to numerical prediction and temporal questions.
2026AIM (clipped, flattened marginal baseline) baselineTDCR (JSD; lower is better)0.7359epsilon=2.0 · sequence-length=10 · baseline-setting=clipped, flattened marginalsPrivately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular Data
Source quote
L557: AIM (Clipped, \varepsilon=2.0) │ 0.564 │ 0.7359 │ 9.7080 │ 0.7412
2026AIM (clipped, flattened marginal baseline) baselineState transition divergence (average Frobenius norm; lower is better)0.7412epsilon=2.0 · sequence-length=10 · baseline-setting=clipped, flattened marginalsPrivately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular Data
Source quote
L557: AIM (Clipped, \varepsilon=2.0) │ 0.564 │ 0.7359 │ 9.7080 │ 0.7412
2026Direct (Indep, clipped, flattened marginal baseline) baselineMAUVE (Gecko; higher is better)0.596epsilon=10.0 · embedding-model=Gecko · sequence-length=10 · baseline-setting=Direct, independent, clipped, flattened marginalsPrivately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular Data
Source quote
L569: Direct (Indep, Clipped, \varepsilon=10.0) │ 0.596 │ 0.7791 │ 8.4024 │ 0.5497
2026best MemPrompt variant (backbone unspecified) baselineAcc@10.5175LLM-judged semantic accuracy; identified as the best MemPrompt variant in the comparison.LLM-as-RNN: A Recurrent Language Model for Memory Updates and Sequence Prediction
Source quote
L251: The advantage is largest in settings where the ground truth changes over time or conflicts with earlier evidence. On MIMIC-IV, where a patient’s condition can change abruptly, LLM-as-RNN improves Acc@1 by 12.6% (absolute) compared to the best MemPrompt variant (0.6434 vs. 0.5175). Similarly, on S\ │ P 500, where shifts in market regimes invalidate prior “trends,” our method lowers MSE by roughly 6.6% (3.821 vs. 4.090). These results suggest that standard append-only methods (FHC and MemPrompt) are prone to error persistence: once an incorrect diagnosis or outdated sentiment is written into the context, it continues to bias future predictions. In contrast, LLM-as-RNN can actively “forget” or revise these obsolete patterns through its update mechanism.
2026FHC (Llama-3-70B) baselineAcc@10.4126params=70B · backbone=Llama-3-70BLLM-as-RNN: A Recurrent Language Model for Memory Updates and Sequence Prediction
Source quote
L253: A direct comparison between LLM-as-RNN and FHC underscores the inefficiency of raw context. Although FHC receives a complete, lossless history, it consistently underperforms our compressed-state approach (e.g., for Llama-3-70B, FHC Acc@1 is 0.4126 vs. 0.5804 for LLM-as-RNN). This indicates that the bottleneck in sequential prediction is not how much information is available, but how well that information is curated. FHC is vulnerable to attention dilution and noise, whereas LLM-as-RNN acts as an information filter that preserves only the signals relevant for the next prediction.
2026Self-Consistency baselineAUROC0.8368params=7B · backbone=Qwen2.5-7B-Instruct · generation-budget=N=16Guideline-Grounded Evidence Accumulation for High-Stakes Agent Verification
Source quote
L574: Method │ Complex. │ \#LLM Calls │ \#Tokens(k) │ AUROC │ Brier \\\multicolumn{6}{c}{Agent Backbone: Qwen2.5-7B-Instruct} \\Self-Consistency │ O(T\cdot N) │ 78.3 │ 135.2 │ 0.8368 │ 0.1886
2026Self-Consistency baselineBrier0.1886params=7B · backbone=Qwen2.5-7B-Instruct · generation-budget=N=16Guideline-Grounded Evidence Accumulation for High-Stakes Agent Verification
Source quote
L574: Method │ Complex. │ \#LLM Calls │ \#Tokens(k) │ AUROC │ Brier \\\multicolumn{6}{c}{Agent Backbone: Qwen2.5-7B-Instruct} \\Self-Consistency │ O(T\cdot N) │ 78.3 │ 135.2 │ 0.8368 │ 0.1886
2026GraphCare-BAT adapted baselineHits@10.609split: held-outAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L711: 0.609
2026MM-KG query-conditioned retrieval baselineAUROC0.712split: testAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L820: SapBERT vector retrieval (0.712, p=0.01); the remaining policies score 0.062–0.204 lower (Figure 4), and
2026GraphCare-BAT adapted (identity-hard subset) baseline non-standard sliceHits@10.375split: held-outAligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMs
Source quote
L713: 0.375
2026Qwen3-8b (Base; all features) baselineAUROC0.6392model=Qwen3-8b · params=8b · features=all · outcomes=average across 7REACT-LLM: A Benchmark for Evaluating LLM Integration with Causal Features in Clinical Prognostic Tasks
Source quote
L397: 0.6392
2026BioMedBERT clinical-notes model baselineAUROC0.87510-shot · modalities=EHR+clinical-notes · notes-encoder=BioMedBERT · encoder-training=frozen · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L115: \checkmark │ × │ × │ \checkmark │ BioMedBERT \cite{pubmedbert} │ 0.8751 │ 0.4599 │ 0.7107
2026BioMedBERT clinical-notes model baselineAUPRC0.45990-shot · modalities=EHR+clinical-notes · notes-encoder=BioMedBERT · encoder-training=frozen · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L115: \checkmark │ × │ × │ \checkmark │ BioMedBERT \cite{pubmedbert} │ 0.8751 │ 0.4599 │ 0.7107
2026EHR-only baseline baselineAUROC0.86510-shot · modalities=EHR-only · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L131: Table~\ref{tab:modality_encoder_results} evaluates pretrained encoder choice in bimodal settings on ICU mortality, with the EHR-only baseline at 0.8651/0.4561/0.7182 (AUROC/AUPRC/F1). Adding an auxiliary modality does not uniformly improve over this baseline: CXR with either encoder performs below the baseline across all three metrics; ECG with CSFM \cite{gu2026cardiac} improves AUROC (0.8703 vs.\ 0.8651) but lowers AUPRC and F1; clinical notes with BioMedBERT \cite{pubmedbert} is the only configuration to exceed the baseline on both AUROC and AUPRC (0.8751/0.4599), while still trailing on F1. Encoder choice nonetheless has a clear within-modality effect: BioMedCLIP \cite{zhang2023biomedclip} outperforms ViT-MAE \cite{he2022mae} on CXR; CSFM outperforms ECG-FM \cite{mckeen2025ecg} on ECG with a notable AUPRC gap (0.426 vs.\ 0.407); and BioMedBERT substantially outperforms BERT \cite{devlin2019bert} on notes across all metrics. For CXR and notes, the advantage comes from domain-adapted pretraining over general-purpose models; for ECG, CSFM benefits from training on a larger and more diverse cardiac corpus. The unified model conditioned on all three modalities (Table~\ref{tab:modality_encoder_results}, final row; BioMedCLIP for CXR, CSFM for ECG, and BioMedBERT for notes) also fails to surpass the EHR-only baseline, indicating that simply combining modalities does not yield additive gains.
2026EHR-only baseline baselineAUPRC0.45610-shot · modalities=EHR-only · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L131: Table~\ref{tab:modality_encoder_results} evaluates pretrained encoder choice in bimodal settings on ICU mortality, with the EHR-only baseline at 0.8651/0.4561/0.7182 (AUROC/AUPRC/F1). Adding an auxiliary modality does not uniformly improve over this baseline: CXR with either encoder performs below the baseline across all three metrics; ECG with CSFM \cite{gu2026cardiac} improves AUROC (0.8703 vs.\ 0.8651) but lowers AUPRC and F1; clinical notes with BioMedBERT \cite{pubmedbert} is the only configuration to exceed the baseline on both AUROC and AUPRC (0.8751/0.4599), while still trailing on F1. Encoder choice nonetheless has a clear within-modality effect: BioMedCLIP \cite{zhang2023biomedclip} outperforms ViT-MAE \cite{he2022mae} on CXR; CSFM outperforms ECG-FM \cite{mckeen2025ecg} on ECG with a notable AUPRC gap (0.426 vs.\ 0.407); and BioMedBERT substantially outperforms BERT \cite{devlin2019bert} on notes across all metrics. For CXR and notes, the advantage comes from domain-adapted pretraining over general-purpose models; for ECG, CSFM benefits from training on a larger and more diverse cardiac corpus. The unified model conditioned on all three modalities (Table~\ref{tab:modality_encoder_results}, final row; BioMedCLIP for CXR, CSFM for ECG, and BioMedBERT for notes) also fails to surpass the EHR-only baseline, indicating that simply combining modalities does not yield additive gains.
2026GRU baseline (no explicit time) baselineRecall@1037.9%MIMIC-IV; best-performing hyperparameters for each approach; evaluated by retrieving ev…Does Temporal Encoding Matter? Evidence from GRU-based Clinical Foundation Models
Source quote
L86: 37.9%
2026GRU baseline (no explicit time) baselinePrecision@1038.7%MIMIC-IV; best-performing hyperparameters for each approach; evaluated by retrieving ev…Does Temporal Encoding Matter? Evidence from GRU-based Clinical Foundation Models
Source quote
L87: 38.7%
2025ETHOS proposedAUC0.936split: test · version=2.2 · extension=EDFoundation model of electronic medical records for adaptive risk estimation
Source quote
L349: \caption{ROC Curves for ETHOS Across All Prediction Tasks. ROC curves and corresponding area under the curve (AUC) values with 95% confidence intervals are shown for seven prediction tasks: Hospital Mortality, ICU Admission, Prolonged Stay (>10 days), Composite Outcome (Hospital Mortality + ICU Admission + Prolonged Stay), Hospitalization at Triage, Critical Outcome Within 12h at Triage, and Emergency Department (ED) Re-presentation Within 72h. Each plot includes the fitted ROC curve (orange), unique thresholds (crosses), and the 95% confidence interval (gray shading). ETHOS demonstrates high predictive performance across all tasks, with AUC values ranging from 0.740 (ED Re-presentation) to 0.936 (Hospital Mortality).}
2025ETHOS proposedAUC0.740horizon=72h · version=2.2 · extension=EDFoundation model of electronic medical records for adaptive risk estimation
Source quote
L349: \caption{ROC Curves for ETHOS Across All Prediction Tasks. ROC curves and corresponding area under the curve (AUC) values with 95% confidence intervals are shown for seven prediction tasks: Hospital Mortality, ICU Admission, Prolonged Stay (>10 days), Composite Outcome (Hospital Mortality + ICU Admission + Prolonged Stay), Hospitalization at Triage, Critical Outcome Within 12h at Triage, and Emergency Department (ED) Re-presentation Within 72h. Each plot includes the fitted ROC curve (orange), unique thresholds (crosses), and the 95% confidence interval (gray shading). ETHOS demonstrates high predictive performance across all tasks, with AUC values ranging from 0.740 (ED Re-presentation) to 0.936 (Hospital Mortality).}
2025ETHOS proposedBrier score0.014split: test · version=2.2 · extension=ED · evaluation=calibrationFoundation model of electronic medical records for adaptive risk estimation
Source quote
L353: \caption{Calibration Curves for ETHOS Predictions Across Clinical Outcomes with 95% Confidence Intervals Determined by Bootstrapping. This figure presents calibration curves evaluating the reliability of ETHOS probability predictions across six key clinical outcomes: hospital mortality, ICU admission, prolonged hospital stay, composite risk score (HM+IA+PS), hospitalization at triage, critical outcome within 12 hours at triage, and ED re-presentation within 72 hours. The calibration curves compare predicted probabilities (x-axis) against observed event frequencies (y-axis), with perfect calibration represented by the dashed diagonal line, while the solid orange line shows ETHOS calibration performance, and the shaded gray region represents the 95% confidence interval (CI) derived from bootstrapping. Each plot includes the Brier score, a metric assessing probabilistic prediction accuracy, where lower values indicate better calibration, with 0.00–0.05 classified as excellent, 0.05–0.10 as good, 0.10–0.20 as acceptable, and values above 0.20 as poor calibration. ETHOS demonstrates excellent calibration for hospital mortality (Brier score: 0.014), critical outcome within 12 hours (0.031), and ED re-presentation (0.041), while ICU admission (0.064), prolonged stay (0.067), and the composite risk score (0.090) exhibit good calibration, closely following the ideal calibration curve. Hospitalization at triage (0.143) is categorized as acceptable calibration, with some deviations at higher predicted probabilities, suggesting areas for potential improvement. Overall, ETHOS exhibits strong calibration across most clinical tasks, particularly in predicting mortality, early critical deterioration, and ED re-presentation, with acceptable performance for hospitalization risk at triage. These findings highlight ETHOS’s reliability in translating probability estimates into clinically meaningful risk stratifications, supporting its potential as a robust AI-driven decision support tool for real-time risk prediction and clinical decision-making.}
2025ETHOS proposedBrier score0.064split: test · version=2.2 · extension=ED · evaluation=calibrationFoundation model of electronic medical records for adaptive risk estimation
Source quote
L353: \caption{Calibration Curves for ETHOS Predictions Across Clinical Outcomes with 95% Confidence Intervals Determined by Bootstrapping. This figure presents calibration curves evaluating the reliability of ETHOS probability predictions across six key clinical outcomes: hospital mortality, ICU admission, prolonged hospital stay, composite risk score (HM+IA+PS), hospitalization at triage, critical outcome within 12 hours at triage, and ED re-presentation within 72 hours. The calibration curves compare predicted probabilities (x-axis) against observed event frequencies (y-axis), with perfect calibration represented by the dashed diagonal line, while the solid orange line shows ETHOS calibration performance, and the shaded gray region represents the 95% confidence interval (CI) derived from bootstrapping. Each plot includes the Brier score, a metric assessing probabilistic prediction accuracy, where lower values indicate better calibration, with 0.00–0.05 classified as excellent, 0.05–0.10 as good, 0.10–0.20 as acceptable, and values above 0.20 as poor calibration. ETHOS demonstrates excellent calibration for hospital mortality (Brier score: 0.014), critical outcome within 12 hours (0.031), and ED re-presentation (0.041), while ICU admission (0.064), prolonged stay (0.067), and the composite risk score (0.090) exhibit good calibration, closely following the ideal calibration curve. Hospitalization at triage (0.143) is categorized as acceptable calibration, with some deviations at higher predicted probabilities, suggesting areas for potential improvement. Overall, ETHOS exhibits strong calibration across most clinical tasks, particularly in predicting mortality, early critical deterioration, and ED re-presentation, with acceptable performance for hospitalization risk at triage. These findings highlight ETHOS’s reliability in translating probability estimates into clinically meaningful risk stratifications, supporting its potential as a robust AI-driven decision support tool for real-time risk prediction and clinical decision-making.}
2025ETHOS proposedBrier score0.067split: test · version=2.2 · extension=ED · evaluation=calibrationFoundation model of electronic medical records for adaptive risk estimation
Source quote
L353: \caption{Calibration Curves for ETHOS Predictions Across Clinical Outcomes with 95% Confidence Intervals Determined by Bootstrapping. This figure presents calibration curves evaluating the reliability of ETHOS probability predictions across six key clinical outcomes: hospital mortality, ICU admission, prolonged hospital stay, composite risk score (HM+IA+PS), hospitalization at triage, critical outcome within 12 hours at triage, and ED re-presentation within 72 hours. The calibration curves compare predicted probabilities (x-axis) against observed event frequencies (y-axis), with perfect calibration represented by the dashed diagonal line, while the solid orange line shows ETHOS calibration performance, and the shaded gray region represents the 95% confidence interval (CI) derived from bootstrapping. Each plot includes the Brier score, a metric assessing probabilistic prediction accuracy, where lower values indicate better calibration, with 0.00–0.05 classified as excellent, 0.05–0.10 as good, 0.10–0.20 as acceptable, and values above 0.20 as poor calibration. ETHOS demonstrates excellent calibration for hospital mortality (Brier score: 0.014), critical outcome within 12 hours (0.031), and ED re-presentation (0.041), while ICU admission (0.064), prolonged stay (0.067), and the composite risk score (0.090) exhibit good calibration, closely following the ideal calibration curve. Hospitalization at triage (0.143) is categorized as acceptable calibration, with some deviations at higher predicted probabilities, suggesting areas for potential improvement. Overall, ETHOS exhibits strong calibration across most clinical tasks, particularly in predicting mortality, early critical deterioration, and ED re-presentation, with acceptable performance for hospitalization risk at triage. These findings highlight ETHOS’s reliability in translating probability estimates into clinically meaningful risk stratifications, supporting its potential as a robust AI-driven decision support tool for real-time risk prediction and clinical decision-making.}
2025ETHOS proposedBrier score0.090split: test · version=2.2 · extension=ED · evaluation=calibrationFoundation model of electronic medical records for adaptive risk estimation
Source quote
L353: \caption{Calibration Curves for ETHOS Predictions Across Clinical Outcomes with 95% Confidence Intervals Determined by Bootstrapping. This figure presents calibration curves evaluating the reliability of ETHOS probability predictions across six key clinical outcomes: hospital mortality, ICU admission, prolonged hospital stay, composite risk score (HM+IA+PS), hospitalization at triage, critical outcome within 12 hours at triage, and ED re-presentation within 72 hours. The calibration curves compare predicted probabilities (x-axis) against observed event frequencies (y-axis), with perfect calibration represented by the dashed diagonal line, while the solid orange line shows ETHOS calibration performance, and the shaded gray region represents the 95% confidence interval (CI) derived from bootstrapping. Each plot includes the Brier score, a metric assessing probabilistic prediction accuracy, where lower values indicate better calibration, with 0.00–0.05 classified as excellent, 0.05–0.10 as good, 0.10–0.20 as acceptable, and values above 0.20 as poor calibration. ETHOS demonstrates excellent calibration for hospital mortality (Brier score: 0.014), critical outcome within 12 hours (0.031), and ED re-presentation (0.041), while ICU admission (0.064), prolonged stay (0.067), and the composite risk score (0.090) exhibit good calibration, closely following the ideal calibration curve. Hospitalization at triage (0.143) is categorized as acceptable calibration, with some deviations at higher predicted probabilities, suggesting areas for potential improvement. Overall, ETHOS exhibits strong calibration across most clinical tasks, particularly in predicting mortality, early critical deterioration, and ED re-presentation, with acceptable performance for hospitalization risk at triage. These findings highlight ETHOS’s reliability in translating probability estimates into clinically meaningful risk stratifications, supporting its potential as a robust AI-driven decision support tool for real-time risk prediction and clinical decision-making.}
2025SHy (K=5, Z=2) proposednDCG@2064.43%split: test · K=5 · Z=2Self-Explaining Hypergraph Neural Networks for Diagnosis Prediction
Source quote
L158: For both MIMIC-III and MIMIC-IV, where the average number of diagnoses per visit ranges between 10 and 20, we set k=\{10, 20\} for Recall@k and nDCG@k. \tableref{tab:predictive_expt} compares the performance of \texttt{SHy}\xspace with baseline models for diagnosis prediction, along with the count of learnable parameters for each model. Overall, \texttt{SHy}\xspace delivers strong predictive performance, surpassing most baselines across all metrics on both datasets. In particular, \texttt{SHy}\xspace outperforms ConCare and Doctor AI, two black-box models, by up to 37.44% in Recall@10 (MIMIC-III) and 64.43% in nDCG@20 (MIMIC-IV), respectively. In contrast, \texttt{SHy}\xspace's edge over T-LSTM isn't as pronounced, especially on MIMIC-IV, which can be attributed to T-LSTM's much larger number of parameters. The large model size of T-LSTM can bring high expressiveness given ample training data. When juxtaposed with interpretable models, \texttt{SHy}\xspace's superiority is even more pronounced: outperforming RETAIN, Dipole, and Timeline by up to 70.53% in Recall@20 on MIMIC-IV, 66.84% in nDCG@10 on MIMIC-IV, and 28.50% in nDCG@10 on MIMIC-III, respectively. It is intriguing to note that \texttt{SHy}\xspace's margin over AdaCare is much narrower (4.39% in Recall@20 on MIMIC-III), with the difference reducing further on MIMIC-IV. This is potentially due to AdaCare's larger size.