MIMIC-IV
123 papers · 397 extracted observations · mortality prediction · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MEDS-Tab SOTA frontier | 0.811 | 2024-01-01 | Result for MIMIC-IV; the table reports paired results in MIMIC-IV/Columbia order. Eva… | MEDS Decentralized, Extensible Validation (MEDS-DEV) Benchmark: Establishing Reproducibility and Comparability in ML for HealthSource quote0.811/0.761 |
| 2 | Performance-optimized predictive model g-\theta (lg) (+1 variant) | 0.746 | 2024-04-01 | groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349 · MIMIC-IV cohort after preprocessing (N=9,349); race groups White vs Non-White; 5-fold… | Explainable AI for Fair Sepsis Mortality Predictive ModelSource quoteAUC │ ACC │ TPR-Diff │ FPR-Diff │ EOD (\mathcal{E}) g-\theta (lg)(X) │ 0.746 │ 0.675 │ 0.071 │ 0.064 │ 0.068 |
| 3 | GAT-guided agent-discovered expression | 0.676 | 2026-10-01 | External validation; systemic lupus erythematosus (SLE) disease cell. The table repor… | Agentic discovery of blood biomarker from distilled private health recordsSource quote0.516 [0.501, 0.563] / 0.676 [0.633, 0.723] |
Regimefine-tuned (22)0-shot (19)age-matched-cohort (7)offline-rl (6)black-box (6)out-of-distribution (4)
Showing 150 of 397 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | StAR proposed | CI width | 2.021 | subset=Medical ICU · F-statistic=5.66 · sample-size=n=21,762 · confidence-level=95% | Adaptive Inference with Weak InstrumentsSource quoteL704: 2.021 |
| 2026 | Qwen3-4B (Mech) proposed | Macro-F1 | 0.51 | params=4B · backbone=Qwen3-4B | Characterize Then Distill: Mechanistic Reasoning in Large Output SpacesSource quoteL997: \gain{0.51}{0.12} |
| 2026 | MIMIC-IV multimodal pipeline proposed | Runtime (clock time) | 2,430.44 seconds | hardware=Intel Core i7; 16 GB DDR4 RAM; Windows 11 · modalities=notes+x-ray · sample-size=100 | A Multimodal Data Processing Pipeline for MIMIC-IV DatasetSource quoteL212: Integrated Modalities │ Runtime Notes + X-ray (n:100) │ 2,430.44 |
| 2026 | MIMIC-IV multimodal pipeline proposed | Runtime (clock time) | 2,479.06 seconds | hardware=Intel Core i7; 16 GB DDR4 RAM; Windows 11 · modalities=notes+waveforms · sample-size=100 | A Multimodal Data Processing Pipeline for MIMIC-IV DatasetSource quoteL213: Notes + Waveforms (n:100) │ 2,479.06 |
| 2026 | MIMIC-IV multimodal pipeline proposed | Runtime (clock time) | 0.31 seconds | hardware=Intel Core i7; 16 GB DDR4 RAM; Windows 11 · modalities=waveforms · sample-size=50 | A Multimodal Data Processing Pipeline for MIMIC-IV DatasetSource quoteL214: Waveforms (n:50) │ 0.31 |
| 2026 | MIMIC-IV multimodal pipeline proposed | Runtime (clock time) | 300 seconds | hardware=Intel Core i7; 16 GB DDR4 RAM; Windows 11 · modalities=structured data+notes+waveforms · sample-size=200 | A Multimodal Data Processing Pipeline for MIMIC-IV DatasetSource quoteL217: Structured + Notes + Waveforms (n:200) │ 300 |
| 2026 | MIMIC-IV multimodal pipeline proposed | Runtime (clock time) | 2,735.85 seconds | hardware=Intel Core i7; 16 GB DDR4 RAM; Windows 11 · modalities=structured data+notes+waveforms+x-ray+2D echo · sample-size=200 per modality | A Multimodal Data Processing Pipeline for MIMIC-IV DatasetSource quoteL218: Structured + Notes + Waveforms (n:200) + X-ray (n:200) + 2D Echo (n:200) │ 2,735.85 |
| 2026 | MedCoRAG proposed | Precision | 81.32% | split: test · params=8B · subset=13 hepatic disease classes · teacher=Qwen3-Max · backbone=Llama-3.1-8B-Instruct | MedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty ConsensusSource quoteL285: MedCoRAG │ 81.32 │ 79.18 │ 79.12 │ 78.99 |
| 2026 | MedCoRAG proposed | Recall | 79.18% | split: test · params=8B · subset=13 hepatic disease classes · teacher=Qwen3-Max · backbone=Llama-3.1-8B-Instruct | MedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty ConsensusSource quoteL285: MedCoRAG │ 81.32 │ 79.18 │ 79.12 │ 78.99 |
| 2026 | MedCoRAG proposed | F1-score | 79.12% | split: test · params=8B · subset=13 hepatic disease classes · teacher=Qwen3-Max · backbone=Llama-3.1-8B-Instruct | MedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty ConsensusSource quoteL285: MedCoRAG │ 81.32 │ 79.18 │ 79.12 │ 78.99 |
| 2026 | MedCoRAG proposed | F0.5-score | 78.99% | split: test · params=8B · subset=13 hepatic disease classes · teacher=Qwen3-Max · backbone=Llama-3.1-8B-Instruct | MedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty ConsensusSource quoteL285: MedCoRAG │ 81.32 │ 79.18 │ 79.12 │ 78.99 |
| 2026 | TI-SAE (soft) proposed | AOPC | .130 | out-of-distribution | Temporal Island Sparse Autoencoders for Interpreting Clinical Time-Series ModelsSource quoteL531: .130 |
| 2026 | TI-SAE (soft) proposed | AUROC | .756 | out-of-distribution | Temporal Island Sparse Autoencoders for Interpreting Clinical Time-Series ModelsSource quoteL533: .756/.370 |
| 2026 | TI-SAE (soft) proposed | AUPRC | .370 | out-of-distribution | Temporal Island Sparse Autoencoders for Interpreting Clinical Time-Series ModelsSource quoteL533: .756/.370 |
| 2026 | Proposed TCF model (No Share) proposed | PRC | 0.419 | features=195 · configuration=No Share | Time-Conditioned Foreseeing: An EHR-Specific Foundation Model for Irregular Dynamics and Calendrical TimeSource quoteL390: 0.419 |
| 2026 | TGTFULL proposed | race AUROC gap (max–min) | 0.1291 | Matched graph-structure ablation with identical data splits, seeds, and training settin… | A Controlled Study of Fairness Interventions for Temporal Graph Transformers on ICU Mortality PredictionSource quoteL181: Under matched training (Figure 5), TGTFULL is comparable to LSTM in overall AUROC (0.8328 vs. 0.8281) but has a smaller race AUROC gap (0.1291 vs. 0.1352). Decomposing the change in race gap relative to LSTM, TGTTEMPORAL increases the race gap by +0.0297 while TGTCLINICAL decreases it by −0.005; we present this only as a difference relative to LSTM, not as a formal causal attribution. The pattern is consistent with the hypothesis that clinical-similarity edges encode lag relationships that are less correlated with demographic features than raw temporal adjacency, but our experiments do not establish a causal mechanism. |
| 2026 | Curve-NECA (NECA-augmented predictor) proposed non-standard slice | PR-AUC | 0.520 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL667: 0.520 |
| 2026 | Curve-NECA (NECA-augmented predictor) proposed non-standard slice | PR-AUC | 0.345 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL672: 0.345 |
| 2026 | Curve-NECA (NECA-augmented predictor) proposed non-standard slice | PR-AUC | 0.357 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL677: 0.357 |
| 2026 | Curve-NECA (NECA-augmented predictor) proposed non-standard slice | PR-AUC | 0.289 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL682: 0.289 |
| 2026 | Curve-NECA (NECA-augmented predictor) proposed non-standard slice | ROC-AUC | 0.809 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL669: 0.809 |
| 2026 | Curve-NECA (NECA-augmented predictor) proposed non-standard slice | ROC-AUC | 0.693 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL674: 0.693 |
| 2026 | Curve-NECA (NECA-augmented predictor) proposed non-standard slice | ROC-AUC | 0.674 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL679: 0.674 |
| 2026 | Curve-NECA (NECA-augmented predictor) proposed non-standard slice | ROC-AUC | 0.696 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL684: 0.696 |
| 2026 | Calibrated XGBoost (after age-matched resampling) proposed | F1 score | 0.8108 | age-matched-cohort | Multidimensional Suicide Risk Assessment with Machine Learning using Electronic Health RecordsSource quoteL480: prior to age-matched resampling, compared to a 0.8108 F1 |
| 2026 | Calibrated XGBoost (after age-matched resampling) proposed | AUPRC | 0.8891 | age-matched-cohort | Multidimensional Suicide Risk Assessment with Machine Learning using Electronic Health RecordsSource quoteL481: score and a 0.8891 AUPRC after age-matched resampling. |
| 2026 | Calibrated XGBoost (age-matched, 20-seed average) proposed | F1 score | 0.8062 | split: test · age-matched-cohort | Multidimensional Suicide Risk Assessment with Machine Learning using Electronic Health RecordsSource quoteL671: fier achieved an average F1 score of 0.8062 with a 95% con- |
| 2026 | GAT-guided agent-discovered expression proposed | AUC | 0.676 | split: val | Agentic discovery of blood biomarker from distilled private health recordsSource quoteL421: 0.516 [0.501, 0.563] / 0.676 [0.633, 0.723] |
| 2026 | COMBIO (MIMIC-IV mortality task) proposed non-standard slice | AUROC | 0.773 | split: test | COMBIO: Automated Discovery of a Compact Composite Biomarker from Routine Laboratory PanelsSource quoteL435: 0.773 |
| 2026 | COMBIO (MIMIC-IV sepsis case-finding task) proposed non-standard slice | AUROC | 0.781 | split: test | COMBIO: Automated Discovery of a Compact Composite Biomarker from Routine Laboratory PanelsSource quoteL448: 0.781 |
| 2026 | COMBIO (eICU-derived reverse-derivation in-hospital mortality score) proposed | AUROC | 0.771 | split: external | COMBIO: Automated Discovery of a Compact Composite Biomarker from Routine Laboratory PanelsSource quoteL728: 0.771 |
| 2026 | DRIFT proposed | Observed-target MAP MAE gap (shifted minus recorded) | 0.554 mmHg | subset=windows where donor substitution changed at least one supplied future exposure · horizon=8-hour · intervention=future-only patient-action replacement | DRIFT: Direct-Recursive Intervention-Conditioned Forecasting of ICU Physiological TrajectoriesSource quoteL1476: 0.554 |
| 2026 | SparseEHR proposed | Recall@10 | 0.463 | 0-shot · code-system=ICD-10 · transfer-source=OLDW · prediction-horizon=next-visit | SparseEHR: Scalable Foundation Modeling for Structured EHR via Conditional ComputationSource quoteL92: SparseEHR achieves 0.463 Recall@10 and 0.551 Recall@20 on MIMICIV in a zero-shot setting (Table 1). These values are higher than the published baselines we include for context, but the comparison should not be read as a protocol-matched state-of-the-art claim because cohort construction, mapping, and metric definitions may differ. The result instead suggests that large-scale structured-EHR pretraining can transfer across institutions when records are expressed in a common typed-token schema. |
| 2026 | GenRxR proposed | DDI ratio | 7.71 | Reported for admissions in the dataset; DDI ratio measures the proportion of predicted … | Improving Rare Medication Recommendation with Counterfactual Data Augmentation and Large Language ModelsSource quoteL456: In addition, GenRxR\xspace yields DDI ratios of 8.29 on MIMIC-\uppercase\expandafter{\romannumeral3}\xspace and 7.71 on MIMIC-\uppercase\expandafter{\romannumeral4}\xspace, which are close to those of the ground-truth prescriptions (8.26 and 7.89, respectively). |
| 2026 | CF-Evolve (Ours; Qwen2.5-7B) proposed | AUROC | 0.7553 | params=7B · backbone=Qwen2.5-7B · task-detail=in-hospital mortality | Counterfactual Self-Evolving Agents for Evidence-Grounded ReasoningSource quoteL1233: \multirow{3}{*}{MIMIC-IV / IHM} │ \multirow{3}{*}{AUROC} │ Qwen2.5-7B │ 0.7000 │ -- │ -- │ 0.7235 │ 0.7553 |
| 2026 | OPL-MT-MNAR proposed | Fitted Q-Evaluation (FQE) | 0.634 | split: test · modalities=low-frequency radiology and microbiology diagnostic text · decision-step=4-hour · observation-window=72-hour | Learning Dynamic Representations and Policies from Multimodal Clinical Time-Series with Informative MissingnessSource quoteL306: As shown in Table~\ref{tab:main_results}, the OPL-MT-MNAR policy reaches FQE 0.679 on MIMIC-III, compared with clinician behavior at 0.528. The gain also persists on the complementary benchmarks, reaching 0.634 on MIMIC-IV versus 0.521 for clinician behavior and 0.604 on eICU versus 0.534. |
| 2026 | Info-Resolution Scaling Law (vocabulary-based ρ estimator) proposed | Refitted target data-scaling exponent β | 0.298 | rho-estimator=vocabulary-based · source-corpus=OpenWebText | On the Invariance and Generality of Neural Scaling LawsSource quoteL508: \hat{\beta}_t │ refitted │ 0.298 │ 0.319 │ 0.321 │ 0.325 |
| 2026 | Info-Resolution Scaling Law (3-gram ρ estimator) proposed | Refitted target data-scaling exponent β | 0.319 | rho-estimator=3-gram entropy · source-corpus=OpenWebText | On the Invariance and Generality of Neural Scaling LawsSource quoteL508: \hat{\beta}_t │ refitted │ 0.298 │ 0.319 │ 0.321 │ 0.325 |
| 2026 | Info-Resolution Scaling Law (compression-based ρ estimator) proposed | Refitted target data-scaling exponent β | 0.321 | rho-estimator=gzip compression · source-corpus=OpenWebText | On the Invariance and Generality of Neural Scaling LawsSource quoteL508: \hat{\beta}_t │ refitted │ 0.298 │ 0.319 │ 0.321 │ 0.325 |
| 2026 | Info-Resolution Scaling Law proposed | Refitted data-scaling exponent β | 0.251 | noise-injection=rho(T)=0.5 | On the Invariance and Generality of Neural Scaling LawsSource quoteL547: \hat{\beta}_t │ refitted │ 0.251 │ 0.244 |
| 2026 | Patients-like-me (PLM), VEM, Meerkat-8B proposed | AUPRC | 49.7 | params=8B · backbone=Meerkat-8B · prediction-window=15-day | Patients-like-me: A Variational LM--GNN Framework for Explainable Clinical PredictionSource quoteL1179: 49.7 │ 80.3 │ 85.3 │ 35.6 │ 77.1 │ 65.7 │ 50.4 |
| 2026 | Patients-like-me (PLM), VEM, Meerkat-8B proposed | Jaccard | 50.4 | params=8B · backbone=Meerkat-8B | Patients-like-me: A Variational LM--GNN Framework for Explainable Clinical PredictionSource quoteL1179: 49.7 │ 80.3 │ 85.3 │ 35.6 │ 77.1 │ 65.7 │ 50.4 |
| 2026 | Patients-like-me (PLM), VEM, Meerkat-8B proposed | Training time per epoch | 2.55 hours per epoch | params=8B · backbone=Meerkat-8B · measurement=training-time-per-epoch | Patients-like-me: A Variational LM--GNN Framework for Explainable Clinical PredictionSource quoteL1204: VEM │ 2.55 │ 80.4 │ 77.1 │ 65.7 │ 50.4 |
| 2026 | Full Hybrid (proposed neuro-symbolic reasoning framework) proposed | Top-1 Accuracy | 57.2% | version=3.1 · label-regime=multi-label | Uncertainty Reasoning with Large Language Models for Explainable Disease DiagnosisSource quoteL453: Full Hybrid │ 57.2 │ 45.6 │ 50.7 │ 76.3 │ 38.2 │ 64.4 │ 48.0 │ 89.3 │ 25.0 │ 75.5 │ 37.6 |
| 2026 | ViSTA-Joint (full V+R) proposed | AP | 0.4650 | params=4B · backbone=4B | ViSTA: A Simple Bridge Extends Visual Alignment to Clinical Time-Series Understanding in Multimodal LLMsSource quoteL435: \textbf{\texttt{ViSTA}\xspace{}: full V+R} │ 0.7440 │ 0.4650 │ 0.7350 │ 0.2651 │ 41.73 |
| 2026 | ViSTA-Joint (full V+R) proposed | AP | 0.2651 | params=4B · backbone=4B | ViSTA: A Simple Bridge Extends Visual Alignment to Clinical Time-Series Understanding in Multimodal LLMsSource quoteL435: \textbf{\texttt{ViSTA}\xspace{}: full V+R} │ 0.7440 │ 0.4650 │ 0.7350 │ 0.2651 │ 41.73 |
| 2026 | ViSTA proposed | AUROC | 0.7376 | params=2B · trainable-params=0.516M | ViSTA: A Simple Bridge Extends Visual Alignment to Clinical Time-Series Understanding in Multimodal LLMsSource quoteL4: Clinical prediction models estimate risk from patient measurements, while large language models support medical text understanding and question answering. Yet their language capabilities do not ensure accurate prediction from structured, high-dimensional clinical time series. Improving this ability would connect risk estimation with flexible questions about a patient's evolving condition. We introduce \texttt{ViSTA}\xspace{}, a compact adapter that incorporates irregular numerical measurements into a pretrained vision-language model's chart representations. It learns corrections to visual tokens while leaving all pretrained parameters unchanged. On MIMIC-IV, \texttt{ViSTA}\xspace{} has the highest mean scores among the compared adaptations on all four metrics for acute kidney injury and mortality prediction across models with 2-9 billion parameters. With 0.516 million trainable parameters, the 2-billion-parameter model reaches an area under the ROC curve of 0.7376 for acute kidney injury, compared with GPT-5.6 Sol's 0.7380 with text input and high reasoning effort. Training for temporal question answering yields 69.27% accuracy at 4 billion parameters with over 90% fewer trainable parameters than low-rank adaptation using charts or numerical text, at a 2.82-4.88 percentage-point accuracy gap. \texttt{ViSTA}\xspace{} extends pretrained language models to numerical prediction and temporal questions. |
| 2026 | PATH (Gemma 4B) proposed | TDCR (JSD; lower is better) | 0.2886 | params=4B · epsilon=2.0 · backbone=Gemma 4B · generation-unit=user-level trajectories | Privately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular DataSource quoteL561: Gemma 4B (\varepsilon=2.0) │ 0.661 │ 0.2886 │ 3.2980 │ 0.3867 |
| 2026 | PATH (Gemma 4B) proposed | State transition divergence (average Frobenius norm; lower is better) | 0.3867 | params=4B · epsilon=2.0 · backbone=Gemma 4B · generation-unit=user-level trajectories | Privately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular DataSource quoteL561: Gemma 4B (\varepsilon=2.0) │ 0.661 │ 0.2886 │ 3.2980 │ 0.3867 |
| 2026 | PATH (Gemma 4B) proposed | MAUVE (Gecko; higher is better) | 0.651 | params=4B · epsilon=10.0 · backbone=Gemma 4B · embedding-model=Gecko | Privately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular DataSource quoteL571: Gemma 4B (\varepsilon=10.0) │ 0.651 │ 0.3784 │ 3.4125 │ 0.3747 |
| 2026 | Tree-of-Evidence (ToE) proposed | AUROC | 0.800 | split: test · 0-shot · params=109M · evidence-budget=k=5 | Tree-of-Evidence: Efficient "System 2" Search for Faithful Multimodal GroundingSource quoteL248: We compare against 10 open-source (M)LLMs (1B–70B parameters), including medical fine-tunes and vision-language models, evaluated on E1 via zero-shot prompting with the full test set. Table~\ref{tab:llm} reports a representative subset; full results are in Appendix~\ref{app:llm_full}; Figure~\ref{fig:llm}. Even the strongest model, Med42-v2-70B (AUROC of 0.745), underperforms ToE at k = 5 (AUROC of 0.800) despite having 640× more parameters. Vision-language models (Gemma-2-12B (V), MedGemma-27B (V)~\cite{team2024gemma}) underperform their text-only counterparts on this task, suggesting that current Multimodal Large Language Models (MLLMs) struggle to extract discriminative signals from raw clinical images for structured prediction. |
| 2026 | PACE-RAG + population prior proposed | Jaccard | 0.237 | split: test · backbone=GPT-4o-mini · split_method=patient-level · test_admissions=1004 | Tabular Population Priors as Structured Retrieval for EHR Medication Set PredictionSource quoteL82: PACE-RAG + prior population prior 0.338 ± 0.017 0.237 admission with current diagnosis strings, observed medication classes, and a patient identifier used to construct chronological prior-admission history. The split is patient-level: |
| 2026 | PACE-RAG proposed | Jaccard | 0.218 | split: test · backbone=GPT-4o-mini · retrieval=FAISS patient records · split_method=patient-level · test_admissions=1004 | Tabular Population Priors as Structured Retrieval for EHR Medication Set PredictionSource quoteL81: 0.303 ± 0.018 0.218 |
| 2026 | MSAM proposed | Jaccard | 0.503 | inputs=diagnoses and procedures · patient-subset=at least two visits · medication-restrictions=with molecular restrictions | Learning Collective Medication Effects via Multi-level Abstraction for Medication RecommendationSource quoteL322: MSAM │ 0.502/0.503 │ 0.762/0.762 │ 0.657/0.659 |
| 2026 | MSAM proposed | F1 | 0.659 | inputs=diagnoses and procedures · patient-subset=at least two visits · medication-restrictions=with molecular restrictions | Learning Collective Medication Effects via Multi-level Abstraction for Medication RecommendationSource quoteL322: MSAM │ 0.502/0.503 │ 0.762/0.762 │ 0.657/0.659 |
| 2026 | STAR-Set Transformer (joint-bias vtb-vtb schedule) proposed | AUC | 0.7158 | bias-schedule=joint-bias vtb-vtb · encoder-layers=4 | Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time SeriesSource quoteL4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models. |
| 2026 | STAR-Set Transformer (joint-bias vtb-vtb schedule) proposed | APR | 0.0026 | bias-schedule=joint-bias vtb-vtb · encoder-layers=4 | Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time SeriesSource quoteL4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models. |
| 2026 | STAR-Set Transformer (joint-bias vtb-vtb schedule) proposed | AUC | 0.9164 | bias-schedule=joint-bias vtb-vtb · encoder-layers=4 | Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time SeriesSource quoteL4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models. |
| 2026 | STAR-Set Transformer (joint-bias vtb-vtb schedule) proposed | APR | 0.2033 | bias-schedule=joint-bias vtb-vtb · encoder-layers=4 | Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time SeriesSource quoteL4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models. |
| 2026 | STAR-Set Transformer (joint-bias vtb-vtb schedule) proposed | AUC | 0.8373 | bias-schedule=joint-bias vtb-vtb · encoder-layers=4 | Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time SeriesSource quoteL4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models. |
| 2026 | STAR-Set Transformer (joint-bias vtb-vtb schedule) proposed | APR | 0.1258 | bias-schedule=joint-bias vtb-vtb · encoder-layers=4 | Structure-Aware Set Transformers: Temporal and Variable-type Attention Biases for Asynchronous Clinical Time SeriesSource quoteL4: Electronic health records (EHR) are irregular, asynchronous multivariate time series. As time-series foundation models increasingly tokenize events rather than discretizing time, the input layout becomes a key design choice. Grids expose time×variable structure but require imputation or missingness masks, risking error or sampling-policy shortcuts. Point-set tokenization avoids discretization but loses within-variable trajectories and time-local cross-variable context (Fig.~\ref{fig:fig1}). We restore these priors in STructure-AwaRe (STAR) Set Transformer by adding parameter-efficient soft attention biases: a temporal locality penalty -|\Delta t|/\tau with learnable timescales and a variable-type affinity B-s_i,s_j from a learned feature-compatibility matrix. We benchmark 10 depth-wise fusion schedules (Fig.~\ref{fig:fig2}). On three ICU prediction tasks, STAR-Set achieves AUC/APR of 0.7158/0.0026 (CPR), 0.9164/0.2033 (mortality), and 0.8373/0.1258 (vasopressor use), outperforming regular-grid, event-time grid, and prior set baselines. Learned \tau and B provide interpretable summaries of temporal context and variable interactions, offering a practical plug-in for context-informed time-series models. |
| 2026 | FC-TPP proposed | MMD | 0.32 | missingness=initial-stage | Forward-Chaining Temporal Point ProcessSource quoteL657: To evaluate robustness under incomplete observations, we simulate realistic missing-event patterns by removing events from four temporal segments: initial, early-middle, late-middle, and final stages. As shown in Fig. 5, FC-TPP outperforms all baselines in different missingness regimes. Performance degradation is most pronounced when early events are missing—an expected limitation for autoregressive models that rely on initial context—but FC-TPP still maintains reasonable quality (MMD = 0.32). In contrast, it achieves the best performance when middle or late-stage events are missing, highlighting its robustness for generation from partial and incomplete histories. |
| 2026 | LLM-as-RNN (backbone unspecified) proposed | Acc@1 | 0.6434 | LLM-judged semantic accuracy; compared in the text with the best MemPrompt variant, who… | LLM-as-RNN: A Recurrent Language Model for Memory Updates and Sequence PredictionSource quoteL251: The advantage is largest in settings where the ground truth changes over time or conflicts with earlier evidence. On MIMIC-IV, where a patient’s condition can change abruptly, LLM-as-RNN improves Acc@1 by 12.6% (absolute) compared to the best MemPrompt variant (0.6434 vs. 0.5175). Similarly, on S\ │ P 500, where shifts in market regimes invalidate prior “trends,” our method lowers MSE by roughly 6.6% (3.821 vs. 4.090). These results suggest that standard append-only methods (FHC and MemPrompt) are prone to error persistence: once an incorrect diagnosis or outdated sentiment is written into the context, it continues to bias future predictions. In contrast, LLM-as-RNN can actively “forget” or revise these obsolete patterns through its update mechanism. |
| 2026 | LLM-as-RNN (Llama-3-70B) proposed | Acc@1 | 0.5804 | params=70B · backbone=Llama-3-70B | LLM-as-RNN: A Recurrent Language Model for Memory Updates and Sequence PredictionSource quoteL253: A direct comparison between LLM-as-RNN and FHC underscores the inefficiency of raw context. Although FHC receives a complete, lossless history, it consistently underperforms our compressed-state approach (e.g., for Llama-3-70B, FHC Acc@1 is 0.4126 vs. 0.5804 for LLM-as-RNN). This indicates that the bottleneck in sequential prediction is not how much information is available, but how well that information is curated. FHC is vulnerable to attention dilution and noise, whereas LLM-as-RNN acts as an information filter that preserves only the signals relevant for the next prediction. |
| 2026 | GLEAN +Active proposed | AUROC | 0.9345 | params=7B · backbone=Qwen2.5-7B-Instruct · generation-budget=N=16 · active-verification-threshold=εu=0.5 | Guideline-Grounded Evidence Accumulation for High-Stakes Agent VerificationSource quoteL577: +Active (\epsilon_u=0.5) │ O(T\cdot K) │ 20.3 │ 132.7 │ 0.9345 │ 0.0992 \\[1.5pt] |
| 2026 | GLEAN +Active proposed | Brier | 0.0992 | params=7B · backbone=Qwen2.5-7B-Instruct · generation-budget=N=16 · active-verification-threshold=εu=0.5 | Guideline-Grounded Evidence Accumulation for High-Stakes Agent VerificationSource quoteL577: +Active (\epsilon_u=0.5) │ O(T\cdot K) │ 20.3 │ 132.7 │ 0.9345 │ 0.0992 \\[1.5pt] |
| 2026 | LONGINUS proposed | Micro-F1 | .597 | training-free | Rethinking Next-Visit Diagnosis Prediction Beyond Aggregate Metrics: Retrieval--Memory Multi-Agent AdjudicationSource quoteL1233: .597† |
| 2026 | LONGINUS (Gemini-3.1-Flash-Lite) proposed | Micro-F1 | .583 | training-free | Rethinking Next-Visit Diagnosis Prediction Beyond Aggregate Metrics: Retrieval--Memory Multi-Agent AdjudicationSource quoteL1259: margins are smaller in aggregate metrics (e.g., .583 |
| 2026 | MM-KG (condition D) proposed | AUROC | .72 | All 3,200 MIMIC join items; condition D supplies both patient modalities and KG relatio… | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quoteL578: 0.651 (.72) |
| 2026 | MM-KG (condition D) proposed | Hits@1 | 0.575 | split: held-out | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quoteL707: 0.575 |
| 2026 | MM-KG full model (trained GNN) proposed | AUROC | 0.804 | split: test · trained | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quoteL869: alone, and the trained GNN reaches 0.804, against 0.778 for a laboratory-only model; laboratory values |
| 2026 | MM-KG full model (identity-hard subset) proposed non-standard slice | Hits@1 | 0.582 | split: held-out | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quoteL709: 0.582 |
| 2026 | MDS-ICU (S4+RealMLP multimodal) proposed | AUROC | 0.90 | ecg=10-second 12-lead · modalities=ECG and clinical data · prediction-horizon=24-hour | A Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician BenchmarkingSource quoteL4: Artificial intelligence (AI) holds substantial promise for supporting clinical decision-making in intensive care units (ICUs), where timely and accurate risk assessment is essential. However, many existing predictive models remain narrowly scoped, focusing on isolated outcomes or limited data modalities, whereas clinicians routinely synthesize longitudinal clinical history, real-time physiological signals, and heterogeneous diagnostic information when assessing patient risk. To address this gap, we developed MDS-ICU, a unified multimodal machine learning framework that fuses routinely collected patient data—including demographics, biometrics, vital signs, laboratory values, ECG waveforms, surgical procedures, and medical device usage—to provide comprehensive predictive support throughout ICU stays. Using data from 63,001 samples across 27,062 patients in MIMIC-IV, we trained a deep learning architecture combining structured state-space (S4) encoders for ECG waveforms with multilayer perceptron (RealMLP) encoders for tabular features to jointly predict 33 clinically relevant outcomes spanning mortality, organ dysfunction, medication requirements, and acute deterioration events. The framework demonstrated strong discriminative performance, achieving AUROCs of 0.90 for 24-hour mortality, 0.92 for sedative administration, 0.97 for invasive mechanical ventilation, and 0.93 for coagulation dysfunction. Calibration analyses showed close alignment between predicted probabilities and observed outcomes, with ECG waveform inclusion yielding consistent improvements in both discrimination and predictive reliability. Direct comparison with clinicians and LLMs showed that model predictions alone outperformed clinicians' judgment and LLM predictions. Furthermore, providing model outputs as augmented decision support further increased predictive accuracy of both clinicians and LLMs. These results demonstrate that multimodal AI frameworks can deliver continuous, clinically meaningful risk stratification across diverse ICU outcomes while empirically showing that AI augments—rather than replaces—clinical expertise. This work establishes a scalable foundation for the integration of high-frequency physiological data into precision-oriented critical care decision support. |
| 2026 | MDS-ICU (S4+RealMLP multimodal) proposed | AUROC | 0.92 | ecg=10-second 12-lead · modalities=ECG and clinical data · prediction-horizon=24-hour | A Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician BenchmarkingSource quoteL4: Artificial intelligence (AI) holds substantial promise for supporting clinical decision-making in intensive care units (ICUs), where timely and accurate risk assessment is essential. However, many existing predictive models remain narrowly scoped, focusing on isolated outcomes or limited data modalities, whereas clinicians routinely synthesize longitudinal clinical history, real-time physiological signals, and heterogeneous diagnostic information when assessing patient risk. To address this gap, we developed MDS-ICU, a unified multimodal machine learning framework that fuses routinely collected patient data—including demographics, biometrics, vital signs, laboratory values, ECG waveforms, surgical procedures, and medical device usage—to provide comprehensive predictive support throughout ICU stays. Using data from 63,001 samples across 27,062 patients in MIMIC-IV, we trained a deep learning architecture combining structured state-space (S4) encoders for ECG waveforms with multilayer perceptron (RealMLP) encoders for tabular features to jointly predict 33 clinically relevant outcomes spanning mortality, organ dysfunction, medication requirements, and acute deterioration events. The framework demonstrated strong discriminative performance, achieving AUROCs of 0.90 for 24-hour mortality, 0.92 for sedative administration, 0.97 for invasive mechanical ventilation, and 0.93 for coagulation dysfunction. Calibration analyses showed close alignment between predicted probabilities and observed outcomes, with ECG waveform inclusion yielding consistent improvements in both discrimination and predictive reliability. Direct comparison with clinicians and LLMs showed that model predictions alone outperformed clinicians' judgment and LLM predictions. Furthermore, providing model outputs as augmented decision support further increased predictive accuracy of both clinicians and LLMs. These results demonstrate that multimodal AI frameworks can deliver continuous, clinically meaningful risk stratification across diverse ICU outcomes while empirically showing that AI augments—rather than replaces—clinical expertise. This work establishes a scalable foundation for the integration of high-frequency physiological data into precision-oriented critical care decision support. |
| 2026 | MDS-ICU (S4+RealMLP multimodal) proposed | AUROC | 0.97 | ecg=10-second 12-lead · modalities=ECG and clinical data | A Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician BenchmarkingSource quoteL4: Artificial intelligence (AI) holds substantial promise for supporting clinical decision-making in intensive care units (ICUs), where timely and accurate risk assessment is essential. However, many existing predictive models remain narrowly scoped, focusing on isolated outcomes or limited data modalities, whereas clinicians routinely synthesize longitudinal clinical history, real-time physiological signals, and heterogeneous diagnostic information when assessing patient risk. To address this gap, we developed MDS-ICU, a unified multimodal machine learning framework that fuses routinely collected patient data—including demographics, biometrics, vital signs, laboratory values, ECG waveforms, surgical procedures, and medical device usage—to provide comprehensive predictive support throughout ICU stays. Using data from 63,001 samples across 27,062 patients in MIMIC-IV, we trained a deep learning architecture combining structured state-space (S4) encoders for ECG waveforms with multilayer perceptron (RealMLP) encoders for tabular features to jointly predict 33 clinically relevant outcomes spanning mortality, organ dysfunction, medication requirements, and acute deterioration events. The framework demonstrated strong discriminative performance, achieving AUROCs of 0.90 for 24-hour mortality, 0.92 for sedative administration, 0.97 for invasive mechanical ventilation, and 0.93 for coagulation dysfunction. Calibration analyses showed close alignment between predicted probabilities and observed outcomes, with ECG waveform inclusion yielding consistent improvements in both discrimination and predictive reliability. Direct comparison with clinicians and LLMs showed that model predictions alone outperformed clinicians' judgment and LLM predictions. Furthermore, providing model outputs as augmented decision support further increased predictive accuracy of both clinicians and LLMs. These results demonstrate that multimodal AI frameworks can deliver continuous, clinically meaningful risk stratification across diverse ICU outcomes while empirically showing that AI augments—rather than replaces—clinical expertise. This work establishes a scalable foundation for the integration of high-frequency physiological data into precision-oriented critical care decision support. |
| 2026 | MDS-ICU (S4+RealMLP multimodal) proposed | AUROC | 0.93 | ecg=10-second 12-lead · modalities=ECG and clinical data | A Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician BenchmarkingSource quoteL4: Artificial intelligence (AI) holds substantial promise for supporting clinical decision-making in intensive care units (ICUs), where timely and accurate risk assessment is essential. However, many existing predictive models remain narrowly scoped, focusing on isolated outcomes or limited data modalities, whereas clinicians routinely synthesize longitudinal clinical history, real-time physiological signals, and heterogeneous diagnostic information when assessing patient risk. To address this gap, we developed MDS-ICU, a unified multimodal machine learning framework that fuses routinely collected patient data—including demographics, biometrics, vital signs, laboratory values, ECG waveforms, surgical procedures, and medical device usage—to provide comprehensive predictive support throughout ICU stays. Using data from 63,001 samples across 27,062 patients in MIMIC-IV, we trained a deep learning architecture combining structured state-space (S4) encoders for ECG waveforms with multilayer perceptron (RealMLP) encoders for tabular features to jointly predict 33 clinically relevant outcomes spanning mortality, organ dysfunction, medication requirements, and acute deterioration events. The framework demonstrated strong discriminative performance, achieving AUROCs of 0.90 for 24-hour mortality, 0.92 for sedative administration, 0.97 for invasive mechanical ventilation, and 0.93 for coagulation dysfunction. Calibration analyses showed close alignment between predicted probabilities and observed outcomes, with ECG waveform inclusion yielding consistent improvements in both discrimination and predictive reliability. Direct comparison with clinicians and LLMs showed that model predictions alone outperformed clinicians' judgment and LLM predictions. Furthermore, providing model outputs as augmented decision support further increased predictive accuracy of both clinicians and LLMs. These results demonstrate that multimodal AI frameworks can deliver continuous, clinically meaningful risk stratification across diverse ICU outcomes while empirically showing that AI augments—rather than replaces—clinical expertise. This work establishes a scalable foundation for the integration of high-frequency physiological data into precision-oriented critical care decision support. |
| 2026 | MDS-ICU (S4+RealMLP multimodal) proposed | Macro-averaged AUROC | 0.865 | ecg=10-second 12-lead · outcomes=33 · tabular-features=801 | A Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician BenchmarkingSource quoteL16: \heading{Contributions} In this work, we introduce a generalist multimodal decision-support system for ICU care that integrates raw ECG waveforms with structured clinical data and explicitly benchmarks AI predictions against clinical judgment. Our contributions are threefold: (1) The construction and public release of a rich multimodal ICU dataset combining demographics, biometrics, vital sign and laboratory trends, surgical procedures, medical device usage, and raw ECG waveforms, together with 33 clinically meaningful deterioration targets spanning mortality, medication administration, organ dysfunction (Sepsis-3 SOFA), and acute clinical events. (2) A unified multimodal fusion framework that integrates high-frequency ECG waveforms with discrete clinical markers into a shared latent representation. This is achieved by combining statistical trend-based feature extraction for non-waveform time series, structured state-space models for ECG waveforms, and an enhanced deep tabular encoder. The architecture supports joint prediction across heterogeneous modalities, yielding high predictive performance (macro AUROC = 0.865) and strong calibration (Brier score = 0.0860). By comparison, the unimodal non-waveform model achieves 0.8583 AUROC and 0.0873 calibration, highlighting the added value of incorporating waveform information. (3) Clinician-centered benchmarks evaluating (i) clinician and LLM judgment versus model predictions where the proposed model outperforms both, and (ii) clinician/LLM judgment augmented with model outputs where on average, AI predictions increased the clinicians' predictive by a Youden index increase of 12% and LLM performance by 16%, demonstrating the model’s clinically meaningful benefit both alone and as augmented support. We envision this resource as both a clinically relevant benchmark and a foundation for reproducible research in ICU decision support. We refer to this dataset and framework as MDS-ICU (Multimodal Decision Support in the ICU). |
| 2026 | TRACER (table label: Ours) proposed | Macro F1 | 0.7942 | Readmission within 15 days after discharge; positive-label proportion 48.84%. Patients … | Trajectory-Aware Clinical Risk Prediction via Severity-Grounded Knowledge Graphs and Retrieval-Augmented GenerationSource quoteL611: Ours │ 0.8938 │ 0.8830 │ 0.7722 │ 0.9688 │ 0.7949 │ 0.7942 │ 0.8752 │ 0.7183 |
| 2026 | Qwen3-8b (GES Opt; LLM-optimized GES features) proposed | AUROC | 0.6537 | model=Qwen3-8b · params=8b · features=LLM-optimized GES causal features · outcomes=average across 7 | REACT-LLM: A Benchmark for Evaluating LLM Integration with Causal Features in Clinical Prognostic TasksSource quoteL402: 0.6537 |
| 2026 | Unified three-modality model (BioMedCLIP for CXR, CSFM for ECG, BioMedBERT for notes) proposed | AUPRC | 0.4330 | 0-shot · modalities=EHR+CXR+ECG+clinical-notes · CXR-encoder=BioMedCLIP · ECG-encoder=CSFM · notes-encoder=BioMedBERT · stochastic-futures=20 | Autoregressive EHR Foundation Models with Multimodal InputsSource quoteL116: \checkmark │ \checkmark │ \checkmark │ \checkmark │ Best per modality │ 0.8460 │ 0.4330 │ 0.6997 |
| 2026 | PACE-RAG proposed | F1 score | 47.22% | split: test · params=8B · backbone=Llama-3.1-8B | PACE-RAG: Patient-Aware Contextual and Evidence-Constrained RAG for Clinical Drug RecommendationSource quoteL22: Evaluated on a Parkinson’s cohort and the MIMIC-IV benchmark using Llama-3.1-8B and Qwen3-8B, PACE-RAG achieved state-of-the-art performance, reaching F1 scores of 80.84% and 47.22%, respectively. |
| 2026 | EveryQuery proposed | Mean AUC (macro-averaged per-task AUROC) | 81.0% | 0-shot | EveryQuery: Zero-Shot Clinical Prediction via Task-Conditioned PretrainingSource quoteL96: 58.0% on AMC, all significantly above chance (Wilcoxon signed-rank p < 10−4). It achieves mean AUCs of 81.0%, |
| 2026 | Factorization Machine (FM score) proposed | Distance Correlation (dCorr) | 36.41 | Evaluated on the same evaluation split with the outcome-specific valid-label mask. Tabl… | A Machine-Learned Comorbidity IndexSource quoteL2394: Factorization Machine (FM score) │ 36.41 │ 35.82 │ 50.80 │ 56.77 │ 31.96 │ 31.28 │ 45.38 │ 20.51 |
| 2026 | Learned projections proposed | Recall@10 | 33.6% | MIMIC-IV; best-performing hyperparameters for each approach; evaluated by retrieving ev… | Does Temporal Encoding Matter? Evidence from GRU-based Clinical Foundation ModelsSource quoteL89: 33.6% |
| 2026 | Learned projections proposed | Precision@10 | 35.0% | MIMIC-IV; best-performing hyperparameters for each approach; evaluated by retrieving ev… | Does Temporal Encoding Matter? Evidence from GRU-based Clinical Foundation ModelsSource quoteL90: 35.0% |
| 2026 | MedCoRAG w/o MA (without Multi-Agent deliberation) ablation | F1-score | 69.70% | split: test · subset=13 hepatic disease classes · component=without Multi-Agent deliberation | MedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty ConsensusSource quoteL345: w/o MA │ 76.30 │ 69.72 │ 69.70 │ 69.14 |
| 2026 | Patients-like-me (PLM), LM-only, Meerkat-8B ablation | AUPRC | 43.9 | params=8B · backbone=Meerkat-8B · training-variant=LM-only · prediction-window=15-day | Patients-like-me: A Variational LM--GNN Framework for Explainable Clinical PredictionSource quoteL1181: 43.9 │ 75.4 │ 79.1 │ 30.9 │ 71.3 │ 60.7 │ 45.8 |
| 2026 | Patients-like-me (PLM), LM-only, Meerkat-8B ablation | Jaccard | 45.8 | params=8B · backbone=Meerkat-8B · training-variant=LM-only | Patients-like-me: A Variational LM--GNN Framework for Explainable Clinical PredictionSource quoteL1181: 43.9 │ 75.4 │ 79.1 │ 30.9 │ 71.3 │ 60.7 │ 45.8 |
| 2026 | LM-only, Meerkat-8B ablation | Training time per epoch | 2.45 hours per epoch | params=8B · backbone=Meerkat-8B · measurement=training-time-per-epoch · training-variant=LM-only | Patients-like-me: A Variational LM--GNN Framework for Explainable Clinical PredictionSource quoteL1208: LM-only │ 2.45 │ 76.8 │ 71.3 │ 60.7 │ 45.8 |
| 2026 | RealMLP unimodal non-waveform model ablation | Macro-averaged AUROC | 0.8583 | modality=routine clinical data without ECG · outcomes=33 | A Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician BenchmarkingSource quoteL16: \heading{Contributions} In this work, we introduce a generalist multimodal decision-support system for ICU care that integrates raw ECG waveforms with structured clinical data and explicitly benchmarks AI predictions against clinical judgment. Our contributions are threefold: (1) The construction and public release of a rich multimodal ICU dataset combining demographics, biometrics, vital sign and laboratory trends, surgical procedures, medical device usage, and raw ECG waveforms, together with 33 clinically meaningful deterioration targets spanning mortality, medication administration, organ dysfunction (Sepsis-3 SOFA), and acute clinical events. (2) A unified multimodal fusion framework that integrates high-frequency ECG waveforms with discrete clinical markers into a shared latent representation. This is achieved by combining statistical trend-based feature extraction for non-waveform time series, structured state-space models for ECG waveforms, and an enhanced deep tabular encoder. The architecture supports joint prediction across heterogeneous modalities, yielding high predictive performance (macro AUROC = 0.865) and strong calibration (Brier score = 0.0860). By comparison, the unimodal non-waveform model achieves 0.8583 AUROC and 0.0873 calibration, highlighting the added value of incorporating waveform information. (3) Clinician-centered benchmarks evaluating (i) clinician and LLM judgment versus model predictions where the proposed model outperforms both, and (ii) clinician/LLM judgment augmented with model outputs where on average, AI predictions increased the clinicians' predictive by a Youden index increase of 12% and LLM performance by 16%, demonstrating the model’s clinically meaningful benefit both alone and as augmented support. We envision this resource as both a clinically relevant benchmark and a foundation for reproducible research in ICU decision support. We refer to this dataset and framework as MDS-ICU (Multimodal Decision Support in the ICU). |
| 2026 | Learned latent compression (k=8, l=4) ablation | AUPRC | 0.4599 | 0-shot · modalities=EHR+clinical-notes · compression=latent (k=8, l=4) · stochastic-futures=20 | Autoregressive EHR Foundation Models with Multimodal InputsSource quoteL128: Table~\ref{tab:latent_compression} reports a compression ablation in a bimodal EHR + clinical notes model on ICU mortality. Mean pooling improves AUROC over no compression but slightly lowers AUPRC and F1, whereas best latent compression configuration improves all three. Sweeping k \in \{8, 16\} and l \in \{1, 2, 4\}, we select k{=}8, l{=}4, which gives the best AUPRC (0.4599) and competitive AUROC; we adopt it for all subsequent experiments. We note that no single setting dominates across all three metrics, so this choice prioritises AUPRC given the class imbalance of the mortality task. |
| 2026 | Standard CP | maximum subgroup gap | 0.049 | Lower endpoint of the abstract-reported range 0.049–0.075; the cited text does not assi… | Missingness-Aware Conformal Prediction Under Cross-Hospital Distribution ShiftSource quoteL6: on GOSSIS, standard CP attains 90% marginal coverage yet covers a low-missingness subgroup at only 0.775. We decompose the subgroup gap into a calibration heterogeneity term ηk and a within-group shift term δk, showing that the Mondrian bound removes ηk and is tighter when ηk exceeds the finite-sample grouping cost. We then introduce a label-free selection rule that chooses the missingness variable with the largest crosssite missingness shift and calibrates within its two subgroups. On GOSSIS, our method halves the maximum subgroup gap from 0.028–0.044 to 0.015–0.021 with less than 1% change in set size; on MIMIC-IV, it reduces the gap from 0.049– |
| 2026 | Standard CP | maximum subgroup gap | 0.075 | Upper endpoint of the abstract-reported range 0.049–0.075; the cited text does not assi… | Missingness-Aware Conformal Prediction Under Cross-Hospital Distribution ShiftSource quoteL7: 0.075 to 0.026–0.046. Subgroup assignment is invariant to model updates and remains stable under deployment-time stress tests where optimizationbased baselines degrade substantially. |
| 2026 | Mondrian CP (missingness grouping) | maximum subgroup gap | 0.026 | Lower endpoint of the abstract-reported range 0.026–0.046; the cited text does not assi… | Missingness-Aware Conformal Prediction Under Cross-Hospital Distribution ShiftSource quoteL7: 0.075 to 0.026–0.046. Subgroup assignment is invariant to model updates and remains stable under deployment-time stress tests where optimizationbased baselines degrade substantially. |
| 2026 | Anderson–Rubin (AR) baseline | CI width | 4.870 | subset=Medical ICU · F-statistic=5.66 · sample-size=n=21,762 · confidence-level=95% | Adaptive Inference with Weak InstrumentsSource quoteL692: 4.870 |
| 2026 | DeepSeek-V3.1-Think baseline | F1-score | 77.61% | split: test · subset=13 hepatic disease classes · backbone=DeepSeek-V3.1-Think | MedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty ConsensusSource quoteL267: DeepSeek-V3.1-Think \cite{deepseekai2024deepseekv3technicalreport} │ 79.59 │ 76.98 │ 77.61 │ 77.05 |
| 2026 | JEV (v1.14.0), Batch baseline | macro-F1 | 0.807 | split: test | Can JEV Support Clinical Trial Criteria Assessment?Source quoteL17: macro-F1 scores on TrialGPT (0.652 vs. 0.660) and MIMIC-IV (0.807 vs. 0.814), whereas |
| 2026 | Qwen Flash, Batch baseline | macro-F1 | 0.814 | split: test | Can JEV Support Clinical Trial Criteria Assessment?Source quoteL17: macro-F1 scores on TrialGPT (0.652 vs. 0.660) and MIMIC-IV (0.807 vs. 0.814), whereas |
| 2026 | JEV (v1.14.0), Single baseline | macro-F1 | 0.808 | split: test | Can JEV Support Clinical Trial Criteria Assessment?Source quoteL500: 0.808 |
| 2026 | Qwen Flash, Single baseline | macro-F1 | 0.732 | split: test | Can JEV Support Clinical Trial Criteria Assessment?Source quoteL514: 0.732 |
| 2026 | Attention baseline | AOPC | .097 | out-of-distribution | Temporal Island Sparse Autoencoders for Interpreting Clinical Time-Series ModelsSource quoteL536: .097 |
| 2026 | MOTOR baseline | PRC | 0.385 | features=195 · configuration=No Share | Time-Conditioned Foreseeing: An EHR-Specific Foundation Model for Irregular Dynamics and Calendrical TimeSource quoteL389: 0.385 |
| 2026 | ETHOS baseline | RMSE | 13426 minutes | interval bucket=0–1 · timestamp resolution=5 minutes | Time-Conditioned Foreseeing: An EHR-Specific Foundation Model for Irregular Dynamics and Calendrical TimeSource quoteL746: 13426 |
| 2026 | LSTM baseline | race AUROC gap (max–min) | 0.1352 | Matched graph-structure ablation with identical data splits, seeds, and training settin… | A Controlled Study of Fairness Interventions for Temporal Graph Transformers on ICU Mortality PredictionSource quoteL181: Under matched training (Figure 5), TGTFULL is comparable to LSTM in overall AUROC (0.8328 vs. 0.8281) but has a smaller race AUROC gap (0.1291 vs. 0.1352). Decomposing the change in race gap relative to LSTM, TGTTEMPORAL increases the race gap by +0.0297 while TGTCLINICAL decreases it by −0.005; we present this only as a difference relative to LSTM, not as a formal causal attribution. The pattern is consistent with the hypothesis that clinical-similarity edges encode lag relationships that are less correlated with demographic features than raw temporal adjacency, but our experiments do not establish a causal mechanism. |
| 2026 | Raw predictor (without NECA) baseline non-standard slice | PR-AUC | 0.419 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL666: 0.419 |
| 2026 | Raw predictor (without NECA) baseline non-standard slice | PR-AUC | 0.319 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL671: 0.319 |
| 2026 | Raw predictor (without NECA) baseline non-standard slice | PR-AUC | 0.340 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL676: 0.340 |
| 2026 | Raw predictor (without NECA) baseline non-standard slice | PR-AUC | 0.276 | split: test | NECA: Neighbor Event Curve Augmentation for Multi-Horizon ICU Deterioration PredictionSource quoteL681: 0.276 |
| 2026 | Logistic Regression (after age-matched resampling) baseline | F1 score | 0.7816 | age-matched-cohort | Multidimensional Suicide Risk Assessment with Machine Learning using Electronic Health RecordsSource quoteL444: 0.7816 |
| 2026 | Random Forest (after age-matched resampling) baseline | F1 score | 0.7981 | age-matched-cohort | Multidimensional Suicide Risk Assessment with Machine Learning using Electronic Health RecordsSource quoteL456: 0.7981 |
| 2026 | Logistic Regression (after age-matched resampling) baseline | AUPRC | 0.8377 | age-matched-cohort | Multidimensional Suicide Risk Assessment with Machine Learning using Electronic Health RecordsSource quoteL445: 0.8377 |
| 2026 | Random Forest (after age-matched resampling) baseline | AUPRC | 0.8701 | age-matched-cohort | Multidimensional Suicide Risk Assessment with Machine Learning using Electronic Health RecordsSource quoteL457: 0.8701 |
| 2026 | Literature-seeded starting expression baseline | AUC | 0.516 | split: val | Agentic discovery of blood biomarker from distilled private health recordsSource quoteL421: 0.516 [0.501, 0.563] / 0.676 [0.633, 0.723] |
| 2026 | Random Forest baseline | F1-score (F1) | 0.645 | split: test · features=LACE-only (4 variables) · train-test-split=80/20 | From Prediction to Structure: Causal Discovery for 30-Day Readmission PredictionSource quoteL72: 0.645 |
| 2026 | Random Forest baseline | ROC AUC (AUC) | 0.689 | split: test · features=LACE-only (4 variables) · train-test-split=80/20 | From Prediction to Structure: Causal Discovery for 30-Day Readmission PredictionSource quoteL73: 0.689 |
| 2026 | Random Forest baseline | F1-score (F1) | 0.836 | split: test · features=all 50 EHR features · train-test-split=80/20 | From Prediction to Structure: Causal Discovery for 30-Day Readmission PredictionSource quoteL113: Forest achieves the strongest results with F1=0.836 and |
| 2026 | Random Forest baseline | ROC AUC (AUC) | 0.907 | split: test · features=all 50 EHR features · train-test-split=80/20 | From Prediction to Structure: Causal Discovery for 30-Day Readmission PredictionSource quoteL136: AUC=0.907, followed by CatBoost and XGBoost. These results show that richer EHR representations provide substantial predictive value beyond LACE alone, and that the predictive signal is robust across multiple non-linear models. |
| 2026 | TFT-action baseline | Observed-target MAP MAE gap (shifted minus recorded) | 0.300 mmHg | subset=windows where donor substitution changed at least one supplied future exposure · horizon=8-hour · intervention=future-only patient-action replacement | DRIFT: Direct-Recursive Intervention-Conditioned Forecasting of ICU Physiological TrajectoriesSource quoteL1477: 0.300 |
| 2026 | Qwen 2.5 7B baseline | Unclear rate — pre-hospitalization functional status | 0.860 rate | model=Qwen 2.5 7B · params=7B · questions=46 · sample_size=200 summaries | CareTransition-Audit: A Benchmark to Audit Discharge Summaries for Efficient Care TransitionsSource quoteL68: Initial results highlight significant gaps in specific documentation areas. Table \ref{tab:unclear} lists the audit questions with the highest ambiguity. The most frequent \texttt{Unclear} element was pre-hospitalization functional status (rate of 0.860), followed by PCP contact information (0.680). |
| 2026 | Qwen 2.5 7B baseline | Unclear rate — PCP contact information | 0.680 rate | model=Qwen 2.5 7B · params=7B · questions=46 · sample_size=200 summaries | CareTransition-Audit: A Benchmark to Audit Discharge Summaries for Efficient Care TransitionsSource quoteL68: Initial results highlight significant gaps in specific documentation areas. Table \ref{tab:unclear} lists the audit questions with the highest ambiguity. The most frequent \texttt{Unclear} element was pre-hospitalization functional status (rate of 0.860), followed by PCP contact information (0.680). |
| 2026 | Zero-shot (Qwen2.5-7B) baseline | AUROC | 0.7000 | 0-shot · params=7B · backbone=Qwen2.5-7B · task-detail=in-hospital mortality | Counterfactual Self-Evolving Agents for Evidence-Grounded ReasoningSource quoteL1233: \multirow{3}{*}{MIMIC-IV / IHM} │ \multirow{3}{*}{AUROC} │ Qwen2.5-7B │ 0.7000 │ -- │ -- │ 0.7235 │ 0.7553 |
| 2026 | Clinician behavior baseline | Fitted Q-Evaluation (FQE) | 0.521 | split: test · decision-step=4-hour · observation-window=72-hour | Learning Dynamic Representations and Policies from Multimodal Clinical Time-Series with Informative MissingnessSource quoteL306: As shown in Table~\ref{tab:main_results}, the OPL-MT-MNAR policy reaches FQE 0.679 on MIMIC-III, compared with clinician behavior at 0.528. The gain also persists on the complementary benchmarks, reaching 0.634 on MIMIC-IV versus 0.521 for clinician behavior and 0.604 on eICU versus 0.534. |
| 2026 | Target-domain ground-truth fit baseline non-standard slice | Ground-truth target data-scaling exponent β | 0.325 | source-corpus=target-domain fit | On the Invariance and Generality of Neural Scaling LawsSource quoteL508: \hat{\beta}_t │ refitted │ 0.298 │ 0.319 │ 0.321 │ 0.325 |
| 2026 | Ground-truth fit baseline non-standard slice | Ground-truth data-scaling exponent β | 0.244 | noise-injection=rho(T)=0.5 | On the Invariance and Generality of Neural Scaling LawsSource quoteL547: \hat{\beta}_t │ refitted │ 0.251 │ 0.244 |
| 2026 | GPT-4o baseline | Top-1 Accuracy | 53.3% | version=3.1 · label-regime=multi-label | Uncertainty Reasoning with Large Language Models for Explainable Disease DiagnosisSource quoteL452: GPT-4o │ 53.3 │ 42.0 │ 47.0 │ 75.3 │ 36.3 │ 63.5 │ 46.2 │ 88.4 │ 24.7 │ 76.2 │ 37.3 |
| 2026 | GPT-5.6 Sol baseline | AUROC | 0.7380 | high-reasoning-effort · input=text | ViSTA: A Simple Bridge Extends Visual Alignment to Clinical Time-Series Understanding in Multimodal LLMsSource quoteL4: Clinical prediction models estimate risk from patient measurements, while large language models support medical text understanding and question answering. Yet their language capabilities do not ensure accurate prediction from structured, high-dimensional clinical time series. Improving this ability would connect risk estimation with flexible questions about a patient's evolving condition. We introduce \texttt{ViSTA}\xspace{}, a compact adapter that incorporates irregular numerical measurements into a pretrained vision-language model's chart representations. It learns corrections to visual tokens while leaving all pretrained parameters unchanged. On MIMIC-IV, \texttt{ViSTA}\xspace{} has the highest mean scores among the compared adaptations on all four metrics for acute kidney injury and mortality prediction across models with 2-9 billion parameters. With 0.516 million trainable parameters, the 2-billion-parameter model reaches an area under the ROC curve of 0.7376 for acute kidney injury, compared with GPT-5.6 Sol's 0.7380 with text input and high reasoning effort. Training for temporal question answering yields 69.27% accuracy at 4 billion parameters with over 90% fewer trainable parameters than low-rank adaptation using charts or numerical text, at a 2.82-4.88 percentage-point accuracy gap. \texttt{ViSTA}\xspace{} extends pretrained language models to numerical prediction and temporal questions. |
| 2026 | AIM (clipped, flattened marginal baseline) baseline | TDCR (JSD; lower is better) | 0.7359 | epsilon=2.0 · sequence-length=10 · baseline-setting=clipped, flattened marginals | Privately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular DataSource quoteL557: AIM (Clipped, \varepsilon=2.0) │ 0.564 │ 0.7359 │ 9.7080 │ 0.7412 |
| 2026 | AIM (clipped, flattened marginal baseline) baseline | State transition divergence (average Frobenius norm; lower is better) | 0.7412 | epsilon=2.0 · sequence-length=10 · baseline-setting=clipped, flattened marginals | Privately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular DataSource quoteL557: AIM (Clipped, \varepsilon=2.0) │ 0.564 │ 0.7359 │ 9.7080 │ 0.7412 |
| 2026 | Direct (Indep, clipped, flattened marginal baseline) baseline | MAUVE (Gecko; higher is better) | 0.596 | epsilon=10.0 · embedding-model=Gecko · sequence-length=10 · baseline-setting=Direct, independent, clipped, flattened marginals | Privately Fine-Tuned LLMs Preserve Temporal Dynamics in Tabular DataSource quoteL569: Direct (Indep, Clipped, \varepsilon=10.0) │ 0.596 │ 0.7791 │ 8.4024 │ 0.5497 |
| 2026 | best MemPrompt variant (backbone unspecified) baseline | Acc@1 | 0.5175 | LLM-judged semantic accuracy; identified as the best MemPrompt variant in the comparison. | LLM-as-RNN: A Recurrent Language Model for Memory Updates and Sequence PredictionSource quoteL251: The advantage is largest in settings where the ground truth changes over time or conflicts with earlier evidence. On MIMIC-IV, where a patient’s condition can change abruptly, LLM-as-RNN improves Acc@1 by 12.6% (absolute) compared to the best MemPrompt variant (0.6434 vs. 0.5175). Similarly, on S\ │ P 500, where shifts in market regimes invalidate prior “trends,” our method lowers MSE by roughly 6.6% (3.821 vs. 4.090). These results suggest that standard append-only methods (FHC and MemPrompt) are prone to error persistence: once an incorrect diagnosis or outdated sentiment is written into the context, it continues to bias future predictions. In contrast, LLM-as-RNN can actively “forget” or revise these obsolete patterns through its update mechanism. |
| 2026 | FHC (Llama-3-70B) baseline | Acc@1 | 0.4126 | params=70B · backbone=Llama-3-70B | LLM-as-RNN: A Recurrent Language Model for Memory Updates and Sequence PredictionSource quoteL253: A direct comparison between LLM-as-RNN and FHC underscores the inefficiency of raw context. Although FHC receives a complete, lossless history, it consistently underperforms our compressed-state approach (e.g., for Llama-3-70B, FHC Acc@1 is 0.4126 vs. 0.5804 for LLM-as-RNN). This indicates that the bottleneck in sequential prediction is not how much information is available, but how well that information is curated. FHC is vulnerable to attention dilution and noise, whereas LLM-as-RNN acts as an information filter that preserves only the signals relevant for the next prediction. |
| 2026 | Self-Consistency baseline | AUROC | 0.8368 | params=7B · backbone=Qwen2.5-7B-Instruct · generation-budget=N=16 | Guideline-Grounded Evidence Accumulation for High-Stakes Agent VerificationSource quoteL574: Method │ Complex. │ \#LLM Calls │ \#Tokens(k) │ AUROC │ Brier \\\multicolumn{6}{c}{Agent Backbone: Qwen2.5-7B-Instruct} \\Self-Consistency │ O(T\cdot N) │ 78.3 │ 135.2 │ 0.8368 │ 0.1886 |
| 2026 | Self-Consistency baseline | Brier | 0.1886 | params=7B · backbone=Qwen2.5-7B-Instruct · generation-budget=N=16 | Guideline-Grounded Evidence Accumulation for High-Stakes Agent VerificationSource quoteL574: Method │ Complex. │ \#LLM Calls │ \#Tokens(k) │ AUROC │ Brier \\\multicolumn{6}{c}{Agent Backbone: Qwen2.5-7B-Instruct} \\Self-Consistency │ O(T\cdot N) │ 78.3 │ 135.2 │ 0.8368 │ 0.1886 |
| 2026 | GraphCare-BAT adapted baseline | Hits@1 | 0.609 | split: held-out | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quoteL711: 0.609 |
| 2026 | MM-KG query-conditioned retrieval baseline | AUROC | 0.712 | split: test | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quoteL820: SapBERT vector retrieval (0.712, p=0.01); the remaining policies score 0.062–0.204 lower (Figure 4), and |
| 2026 | GraphCare-BAT adapted (identity-hard subset) baseline non-standard slice | Hits@1 | 0.375 | split: held-out | Aligning Multimodal Patient Evidence with Biomedical Knowledge Graphs for Clinical LLMsSource quoteL713: 0.375 |
| 2026 | Qwen3-8b (Base; all features) baseline | AUROC | 0.6392 | model=Qwen3-8b · params=8b · features=all · outcomes=average across 7 | REACT-LLM: A Benchmark for Evaluating LLM Integration with Causal Features in Clinical Prognostic TasksSource quoteL397: 0.6392 |
| 2026 | BioMedBERT clinical-notes model baseline | AUROC | 0.8751 | 0-shot · modalities=EHR+clinical-notes · notes-encoder=BioMedBERT · encoder-training=frozen · stochastic-futures=20 | Autoregressive EHR Foundation Models with Multimodal InputsSource quoteL115: \checkmark │ × │ × │ \checkmark │ BioMedBERT \cite{pubmedbert} │ 0.8751 │ 0.4599 │ 0.7107 |
| 2026 | BioMedBERT clinical-notes model baseline | AUPRC | 0.4599 | 0-shot · modalities=EHR+clinical-notes · notes-encoder=BioMedBERT · encoder-training=frozen · stochastic-futures=20 | Autoregressive EHR Foundation Models with Multimodal InputsSource quoteL115: \checkmark │ × │ × │ \checkmark │ BioMedBERT \cite{pubmedbert} │ 0.8751 │ 0.4599 │ 0.7107 |
| 2026 | EHR-only baseline baseline | AUROC | 0.8651 | 0-shot · modalities=EHR-only · stochastic-futures=20 | Autoregressive EHR Foundation Models with Multimodal InputsSource quoteL131: Table~\ref{tab:modality_encoder_results} evaluates pretrained encoder choice in bimodal settings on ICU mortality, with the EHR-only baseline at 0.8651/0.4561/0.7182 (AUROC/AUPRC/F1). Adding an auxiliary modality does not uniformly improve over this baseline: CXR with either encoder performs below the baseline across all three metrics; ECG with CSFM \cite{gu2026cardiac} improves AUROC (0.8703 vs.\ 0.8651) but lowers AUPRC and F1; clinical notes with BioMedBERT \cite{pubmedbert} is the only configuration to exceed the baseline on both AUROC and AUPRC (0.8751/0.4599), while still trailing on F1. Encoder choice nonetheless has a clear within-modality effect: BioMedCLIP \cite{zhang2023biomedclip} outperforms ViT-MAE \cite{he2022mae} on CXR; CSFM outperforms ECG-FM \cite{mckeen2025ecg} on ECG with a notable AUPRC gap (0.426 vs.\ 0.407); and BioMedBERT substantially outperforms BERT \cite{devlin2019bert} on notes across all metrics. For CXR and notes, the advantage comes from domain-adapted pretraining over general-purpose models; for ECG, CSFM benefits from training on a larger and more diverse cardiac corpus. The unified model conditioned on all three modalities (Table~\ref{tab:modality_encoder_results}, final row; BioMedCLIP for CXR, CSFM for ECG, and BioMedBERT for notes) also fails to surpass the EHR-only baseline, indicating that simply combining modalities does not yield additive gains. |
| 2026 | EHR-only baseline baseline | AUPRC | 0.4561 | 0-shot · modalities=EHR-only · stochastic-futures=20 | Autoregressive EHR Foundation Models with Multimodal InputsSource quoteL131: Table~\ref{tab:modality_encoder_results} evaluates pretrained encoder choice in bimodal settings on ICU mortality, with the EHR-only baseline at 0.8651/0.4561/0.7182 (AUROC/AUPRC/F1). Adding an auxiliary modality does not uniformly improve over this baseline: CXR with either encoder performs below the baseline across all three metrics; ECG with CSFM \cite{gu2026cardiac} improves AUROC (0.8703 vs.\ 0.8651) but lowers AUPRC and F1; clinical notes with BioMedBERT \cite{pubmedbert} is the only configuration to exceed the baseline on both AUROC and AUPRC (0.8751/0.4599), while still trailing on F1. Encoder choice nonetheless has a clear within-modality effect: BioMedCLIP \cite{zhang2023biomedclip} outperforms ViT-MAE \cite{he2022mae} on CXR; CSFM outperforms ECG-FM \cite{mckeen2025ecg} on ECG with a notable AUPRC gap (0.426 vs.\ 0.407); and BioMedBERT substantially outperforms BERT \cite{devlin2019bert} on notes across all metrics. For CXR and notes, the advantage comes from domain-adapted pretraining over general-purpose models; for ECG, CSFM benefits from training on a larger and more diverse cardiac corpus. The unified model conditioned on all three modalities (Table~\ref{tab:modality_encoder_results}, final row; BioMedCLIP for CXR, CSFM for ECG, and BioMedBERT for notes) also fails to surpass the EHR-only baseline, indicating that simply combining modalities does not yield additive gains. |
| 2026 | GRU baseline (no explicit time) baseline | Recall@10 | 37.9% | MIMIC-IV; best-performing hyperparameters for each approach; evaluated by retrieving ev… | Does Temporal Encoding Matter? Evidence from GRU-based Clinical Foundation ModelsSource quoteL86: 37.9% |
| 2026 | GRU baseline (no explicit time) baseline | Precision@10 | 38.7% | MIMIC-IV; best-performing hyperparameters for each approach; evaluated by retrieving ev… | Does Temporal Encoding Matter? Evidence from GRU-based Clinical Foundation ModelsSource quoteL87: 38.7% |
| 2025 | ETHOS proposed | AUC | 0.936 | split: test · version=2.2 · extension=ED | Foundation model of electronic medical records for adaptive risk estimationSource quoteL349: \caption{ROC Curves for ETHOS Across All Prediction Tasks. ROC curves and corresponding area under the curve (AUC) values with 95% confidence intervals are shown for seven prediction tasks: Hospital Mortality, ICU Admission, Prolonged Stay (>10 days), Composite Outcome (Hospital Mortality + ICU Admission + Prolonged Stay), Hospitalization at Triage, Critical Outcome Within 12h at Triage, and Emergency Department (ED) Re-presentation Within 72h. Each plot includes the fitted ROC curve (orange), unique thresholds (crosses), and the 95% confidence interval (gray shading). ETHOS demonstrates high predictive performance across all tasks, with AUC values ranging from 0.740 (ED Re-presentation) to 0.936 (Hospital Mortality).} |
| 2025 | ETHOS proposed | AUC | 0.740 | horizon=72h · version=2.2 · extension=ED | Foundation model of electronic medical records for adaptive risk estimationSource quoteL349: \caption{ROC Curves for ETHOS Across All Prediction Tasks. ROC curves and corresponding area under the curve (AUC) values with 95% confidence intervals are shown for seven prediction tasks: Hospital Mortality, ICU Admission, Prolonged Stay (>10 days), Composite Outcome (Hospital Mortality + ICU Admission + Prolonged Stay), Hospitalization at Triage, Critical Outcome Within 12h at Triage, and Emergency Department (ED) Re-presentation Within 72h. Each plot includes the fitted ROC curve (orange), unique thresholds (crosses), and the 95% confidence interval (gray shading). ETHOS demonstrates high predictive performance across all tasks, with AUC values ranging from 0.740 (ED Re-presentation) to 0.936 (Hospital Mortality).} |
| 2025 | ETHOS proposed | Brier score | 0.014 | split: test · version=2.2 · extension=ED · evaluation=calibration | Foundation model of electronic medical records for adaptive risk estimationSource quoteL353: \caption{Calibration Curves for ETHOS Predictions Across Clinical Outcomes with 95% Confidence Intervals Determined by Bootstrapping. This figure presents calibration curves evaluating the reliability of ETHOS probability predictions across six key clinical outcomes: hospital mortality, ICU admission, prolonged hospital stay, composite risk score (HM+IA+PS), hospitalization at triage, critical outcome within 12 hours at triage, and ED re-presentation within 72 hours. The calibration curves compare predicted probabilities (x-axis) against observed event frequencies (y-axis), with perfect calibration represented by the dashed diagonal line, while the solid orange line shows ETHOS calibration performance, and the shaded gray region represents the 95% confidence interval (CI) derived from bootstrapping. Each plot includes the Brier score, a metric assessing probabilistic prediction accuracy, where lower values indicate better calibration, with 0.00–0.05 classified as excellent, 0.05–0.10 as good, 0.10–0.20 as acceptable, and values above 0.20 as poor calibration. ETHOS demonstrates excellent calibration for hospital mortality (Brier score: 0.014), critical outcome within 12 hours (0.031), and ED re-presentation (0.041), while ICU admission (0.064), prolonged stay (0.067), and the composite risk score (0.090) exhibit good calibration, closely following the ideal calibration curve. Hospitalization at triage (0.143) is categorized as acceptable calibration, with some deviations at higher predicted probabilities, suggesting areas for potential improvement. Overall, ETHOS exhibits strong calibration across most clinical tasks, particularly in predicting mortality, early critical deterioration, and ED re-presentation, with acceptable performance for hospitalization risk at triage. These findings highlight ETHOS’s reliability in translating probability estimates into clinically meaningful risk stratifications, supporting its potential as a robust AI-driven decision support tool for real-time risk prediction and clinical decision-making.} |
| 2025 | ETHOS proposed | Brier score | 0.064 | split: test · version=2.2 · extension=ED · evaluation=calibration | Foundation model of electronic medical records for adaptive risk estimationSource quoteL353: \caption{Calibration Curves for ETHOS Predictions Across Clinical Outcomes with 95% Confidence Intervals Determined by Bootstrapping. This figure presents calibration curves evaluating the reliability of ETHOS probability predictions across six key clinical outcomes: hospital mortality, ICU admission, prolonged hospital stay, composite risk score (HM+IA+PS), hospitalization at triage, critical outcome within 12 hours at triage, and ED re-presentation within 72 hours. The calibration curves compare predicted probabilities (x-axis) against observed event frequencies (y-axis), with perfect calibration represented by the dashed diagonal line, while the solid orange line shows ETHOS calibration performance, and the shaded gray region represents the 95% confidence interval (CI) derived from bootstrapping. Each plot includes the Brier score, a metric assessing probabilistic prediction accuracy, where lower values indicate better calibration, with 0.00–0.05 classified as excellent, 0.05–0.10 as good, 0.10–0.20 as acceptable, and values above 0.20 as poor calibration. ETHOS demonstrates excellent calibration for hospital mortality (Brier score: 0.014), critical outcome within 12 hours (0.031), and ED re-presentation (0.041), while ICU admission (0.064), prolonged stay (0.067), and the composite risk score (0.090) exhibit good calibration, closely following the ideal calibration curve. Hospitalization at triage (0.143) is categorized as acceptable calibration, with some deviations at higher predicted probabilities, suggesting areas for potential improvement. Overall, ETHOS exhibits strong calibration across most clinical tasks, particularly in predicting mortality, early critical deterioration, and ED re-presentation, with acceptable performance for hospitalization risk at triage. These findings highlight ETHOS’s reliability in translating probability estimates into clinically meaningful risk stratifications, supporting its potential as a robust AI-driven decision support tool for real-time risk prediction and clinical decision-making.} |
| 2025 | ETHOS proposed | Brier score | 0.067 | split: test · version=2.2 · extension=ED · evaluation=calibration | Foundation model of electronic medical records for adaptive risk estimationSource quoteL353: \caption{Calibration Curves for ETHOS Predictions Across Clinical Outcomes with 95% Confidence Intervals Determined by Bootstrapping. This figure presents calibration curves evaluating the reliability of ETHOS probability predictions across six key clinical outcomes: hospital mortality, ICU admission, prolonged hospital stay, composite risk score (HM+IA+PS), hospitalization at triage, critical outcome within 12 hours at triage, and ED re-presentation within 72 hours. The calibration curves compare predicted probabilities (x-axis) against observed event frequencies (y-axis), with perfect calibration represented by the dashed diagonal line, while the solid orange line shows ETHOS calibration performance, and the shaded gray region represents the 95% confidence interval (CI) derived from bootstrapping. Each plot includes the Brier score, a metric assessing probabilistic prediction accuracy, where lower values indicate better calibration, with 0.00–0.05 classified as excellent, 0.05–0.10 as good, 0.10–0.20 as acceptable, and values above 0.20 as poor calibration. ETHOS demonstrates excellent calibration for hospital mortality (Brier score: 0.014), critical outcome within 12 hours (0.031), and ED re-presentation (0.041), while ICU admission (0.064), prolonged stay (0.067), and the composite risk score (0.090) exhibit good calibration, closely following the ideal calibration curve. Hospitalization at triage (0.143) is categorized as acceptable calibration, with some deviations at higher predicted probabilities, suggesting areas for potential improvement. Overall, ETHOS exhibits strong calibration across most clinical tasks, particularly in predicting mortality, early critical deterioration, and ED re-presentation, with acceptable performance for hospitalization risk at triage. These findings highlight ETHOS’s reliability in translating probability estimates into clinically meaningful risk stratifications, supporting its potential as a robust AI-driven decision support tool for real-time risk prediction and clinical decision-making.} |
| 2025 | ETHOS proposed | Brier score | 0.090 | split: test · version=2.2 · extension=ED · evaluation=calibration | Foundation model of electronic medical records for adaptive risk estimationSource quoteL353: \caption{Calibration Curves for ETHOS Predictions Across Clinical Outcomes with 95% Confidence Intervals Determined by Bootstrapping. This figure presents calibration curves evaluating the reliability of ETHOS probability predictions across six key clinical outcomes: hospital mortality, ICU admission, prolonged hospital stay, composite risk score (HM+IA+PS), hospitalization at triage, critical outcome within 12 hours at triage, and ED re-presentation within 72 hours. The calibration curves compare predicted probabilities (x-axis) against observed event frequencies (y-axis), with perfect calibration represented by the dashed diagonal line, while the solid orange line shows ETHOS calibration performance, and the shaded gray region represents the 95% confidence interval (CI) derived from bootstrapping. Each plot includes the Brier score, a metric assessing probabilistic prediction accuracy, where lower values indicate better calibration, with 0.00–0.05 classified as excellent, 0.05–0.10 as good, 0.10–0.20 as acceptable, and values above 0.20 as poor calibration. ETHOS demonstrates excellent calibration for hospital mortality (Brier score: 0.014), critical outcome within 12 hours (0.031), and ED re-presentation (0.041), while ICU admission (0.064), prolonged stay (0.067), and the composite risk score (0.090) exhibit good calibration, closely following the ideal calibration curve. Hospitalization at triage (0.143) is categorized as acceptable calibration, with some deviations at higher predicted probabilities, suggesting areas for potential improvement. Overall, ETHOS exhibits strong calibration across most clinical tasks, particularly in predicting mortality, early critical deterioration, and ED re-presentation, with acceptable performance for hospitalization risk at triage. These findings highlight ETHOS’s reliability in translating probability estimates into clinically meaningful risk stratifications, supporting its potential as a robust AI-driven decision support tool for real-time risk prediction and clinical decision-making.} |
| 2025 | SHy (K=5, Z=2) proposed | nDCG@20 | 64.43% | split: test · K=5 · Z=2 | Self-Explaining Hypergraph Neural Networks for Diagnosis PredictionSource quoteL158: For both MIMIC-III and MIMIC-IV, where the average number of diagnoses per visit ranges between 10 and 20, we set k=\{10, 20\} for Recall@k and nDCG@k. \tableref{tab:predictive_expt} compares the performance of \texttt{SHy}\xspace with baseline models for diagnosis prediction, along with the count of learnable parameters for each model. Overall, \texttt{SHy}\xspace delivers strong predictive performance, surpassing most baselines across all metrics on both datasets. In particular, \texttt{SHy}\xspace outperforms ConCare and Doctor AI, two black-box models, by up to 37.44% in Recall@10 (MIMIC-III) and 64.43% in nDCG@20 (MIMIC-IV), respectively. In contrast, \texttt{SHy}\xspace's edge over T-LSTM isn't as pronounced, especially on MIMIC-IV, which can be attributed to T-LSTM's much larger number of parameters. The large model size of T-LSTM can bring high expressiveness given ample training data. When juxtaposed with interpretable models, \texttt{SHy}\xspace's superiority is even more pronounced: outperforming RETAIN, Dipole, and Timeline by up to 70.53% in Recall@20 on MIMIC-IV, 66.84% in nDCG@10 on MIMIC-IV, and 28.50% in nDCG@10 on MIMIC-III, respectively. It is intriguing to note that \texttt{SHy}\xspace's margin over AdaCare is much narrower (4.39% in Recall@20 on MIMIC-III), with the difference reducing further on MIMIC-IV. This is potentially due to AdaCare's larger size. |