MIMIC-IV

123 papers · 397 extracted observations · mortality prediction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.70.70.80.8202420252027MEDS-Tab: 0.811 (2024)Fair model g-\theta (fair): 0.723 (2024)Performance-optimized predictive model g-\theta (lg): 0.746 (2024)GAT-guided agent-discovered expression: 0.676 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 21 of 21 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026GAT-guided agent-discovered expression proposedAUC0.676split: valAgentic discovery of blood biomarker from distilled private health records
Source quote
L421: 0.516 [0.501, 0.563] / 0.676 [0.633, 0.723]
2026Literature-seeded starting expression baselineAUC0.516split: valAgentic discovery of blood biomarker from distilled private health records
Source quote
L421: 0.516 [0.501, 0.563] / 0.676 [0.633, 0.723]
2024Performance-optimized predictive model g-\theta (lg) proposedAUC0.746split: val · groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349Explainable AI for Fair Sepsis Mortality Predictive Model
Source quote
L110: AUC │ ACC │ TPR-Diff │ FPR-Diff │ EOD (\mathcal{E}) g-\theta (lg)(X) │ 0.746 │ 0.675 │ 0.071 │ 0.064 │ 0.068
2024Fair model g-\theta (fair) proposedAUC0.723split: val · groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349Explainable AI for Fair Sepsis Mortality Predictive Model
Source quote
L111: g-\theta (fair)(X) │ 0.723 │ 0.637 │ 0.002 │ 0.015 │ 0.008
2024Performance-optimized predictive model g-\theta (lg) proposedACC (Accuracy)0.675split: val · groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349Explainable AI for Fair Sepsis Mortality Predictive Model
Source quote
L110: AUC │ ACC │ TPR-Diff │ FPR-Diff │ EOD (\mathcal{E}) g-\theta (lg)(X) │ 0.746 │ 0.675 │ 0.071 │ 0.064 │ 0.068
2024Fair model g-\theta (fair) proposedACC (Accuracy)0.637split: val · groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349Explainable AI for Fair Sepsis Mortality Predictive Model
Source quote
L111: g-\theta (fair)(X) │ 0.723 │ 0.637 │ 0.002 │ 0.015 │ 0.008
2024Performance-optimized predictive model g-\theta (lg) proposedEOD (\mathcal{E})0.068split: val · groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349Explainable AI for Fair Sepsis Mortality Predictive Model
Source quote
L110: AUC │ ACC │ TPR-Diff │ FPR-Diff │ EOD (\mathcal{E}) g-\theta (lg)(X) │ 0.746 │ 0.675 │ 0.071 │ 0.064 │ 0.068
2024Fair model g-\theta (fair) proposedEOD (\mathcal{E})0.008split: val · groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349Explainable AI for Fair Sepsis Mortality Predictive Model
Source quote
L111: g-\theta (fair)(X) │ 0.723 │ 0.637 │ 0.002 │ 0.015 │ 0.008
2024pyAKI generated labels proposedOverall AKI-stage accuracy1.0split: valpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024pyAKI generated labels proposedUrine-output (UO) accuracy1.0split: val · criterion=urine-outputpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024pyAKI generated labels proposedRelative serum creatinine (SCr) elevation accuracy1.0split: val · criterion=relative-serum-creatinine-elevationpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024MEDS-Tab proposedAUC-ROC0.811split: valMEDS Decentralized, Extensible Validation (MEDS-DEV) Benchmark: Establishing Reproducibility and Comparability in ML for Health
Source quote
L141: 0.811/0.761
2024Human labels (senior physicians) baselineOverall AKI-stage accuracy0.9771split: valpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024Human labels (senior physicians) baselineUrine-output (UO) accuracy0.9664split: val · criterion=urine-outputpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024Human labels (senior physicians) baselineRelative serum creatinine (SCr) elevation accuracy0.9996split: val · criterion=relative-serum-creatinine-elevationpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024MOTOR baselineAUC-ROC0.854split: valMEDS Decentralized, Extensible Validation (MEDS-DEV) Benchmark: Establishing Reproducibility and Comparability in ML for Health
Source quote
L136: 0.854/0.727
2024CorGAN baselineArea Under the Curve (AUC), discriminative prediction0.927split: val · evaluation=5-fold cross-validation · discriminator=logistic regression · training_data=MIMIC-IIIGenerating synthetic electronic health record data: a methodological scoping review with benchmarking on phenotype data and open-source software
Source quote
L198: When evaluated on the MIMIC-IV data, CorGAN outperforms \textcolor{black}{the baselines} in preserving the phecode-wise prevalence, achieving an MMD of 0.234 for absolute differences. \textcolor{black}{However, PromptEHR performs best in relative difference metrics} (RMSPE: 113.5; MAPE: 1418.7). Additionally, \textcolor{black}{since synthetic data were trained on MIMIC-III, it is significantly easier to distinguish them from real MIMIC-IV data. Among all the selected methods, CorGAN remains the most effective, achieving lowest AUC of 0.927.}
2024FLAN-T5 baselineF171.92split: val · fine-tuned · subset=25%-training-data · evaluation=5-fold-cross-validationAre Clinical T5 Models Better for Clinical Text?
Source quote
L1552: 71.92
2024MIMIC-T5 baselineF164.44split: val · fine-tuned · subset=25%-training-data · evaluation=5-fold-cross-validationAre Clinical T5 Models Better for Clinical Text?
Source quote
L1553: 64.44
2023time Transformer (time-only sublayers) ablationmean squared error (MSE)0.0867split: val · depth=same as DuETT · cohort=ICU · target=creatinine · architecture=time-only sublayersDuETT: Dual Event Time Transformer for Electronic Health Records
Source quote
L234: \caption{Reconstruction of masked creatinine measurements for two random validation set patients in the MIMIC-IV ICU dataset. DuETT is compared to models of the same depth that use only event Transformer sublayers or only time Transformer sublayers. The overall validation set reconstruction mean squared error (MSE) follows the same trend: \text{DuETT}{} has a masked event MSE of 0.0754 while the time Transformer has MSE of 0.0867 and the event Transformer has MSE of 0.0916.}
2023event Transformer (event-only sublayers) ablationmean squared error (MSE)0.0916split: val · depth=same as DuETT · cohort=ICU · target=creatinine · architecture=event-only sublayersDuETT: Dual Event Time Transformer for Electronic Health Records
Source quote
L234: \caption{Reconstruction of masked creatinine measurements for two random validation set patients in the MIMIC-IV ICU dataset. DuETT is compared to models of the same depth that use only event Transformer sublayers or only time Transformer sublayers. The overall validation set reconstruction mean squared error (MSE) follows the same trend: \text{DuETT}{} has a masked event MSE of 0.0754 while the time Transformer has MSE of 0.0867 and the event Transformer has MSE of 0.0916.}