MIMIC-IV

123 papers · 397 extracted observations · mortality prediction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.70.70.80.8202420252027MEDS-Tab: 0.811 (2024)Fair model g-\theta (fair): 0.723 (2024)Performance-optimized predictive model g-\theta (lg): 0.746 (2024)GAT-guided agent-discovered expression: 0.676 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 19 of 19 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026SparseEHR proposedRecall@100.4630-shot · code-system=ICD-10 · transfer-source=OLDW · prediction-horizon=next-visitSparseEHR: Scalable Foundation Modeling for Structured EHR via Conditional Computation
Source quote
L92: SparseEHR achieves 0.463 Recall@10 and 0.551 Recall@20 on MIMICIV in a zero-shot setting (Table 1). These values are higher than the published baselines we include for context, but the comparison should not be read as a protocol-matched state-of-the-art claim because cohort construction, mapping, and metric definitions may differ. The result instead suggests that large-scale structured-EHR pretraining can transfer across institutions when records are expressed in a common typed-token schema.
2026Tree-of-Evidence (ToE) proposedAUROC0.800split: test · 0-shot · params=109M · evidence-budget=k=5Tree-of-Evidence: Efficient "System 2" Search for Faithful Multimodal Grounding
Source quote
L248: We compare against 10 open-source (M)LLMs (1B–70B parameters), including medical fine-tunes and vision-language models, evaluated on E1 via zero-shot prompting with the full test set. Table~\ref{tab:llm} reports a representative subset; full results are in Appendix~\ref{app:llm_full}; Figure~\ref{fig:llm}. Even the strongest model, Med42-v2-70B (AUROC of 0.745), underperforms ToE at k = 5 (AUROC of 0.800) despite having 640× more parameters. Vision-language models (Gemma-2-12B (V), MedGemma-27B (V)~\cite{team2024gemma}) underperform their text-only counterparts on this task, suggesting that current Multimodal Large Language Models (MLLMs) struggle to extract discriminative signals from raw clinical images for structured prediction.
2026Unified three-modality model (BioMedCLIP for CXR, CSFM for ECG, BioMedBERT for notes) proposedAUPRC0.43300-shot · modalities=EHR+CXR+ECG+clinical-notes · CXR-encoder=BioMedCLIP · ECG-encoder=CSFM · notes-encoder=BioMedBERT · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L116: \checkmark │ \checkmark │ \checkmark │ \checkmark │ Best per modality │ 0.8460 │ 0.4330 │ 0.6997
2026EveryQuery proposedMean AUC (macro-averaged per-task AUROC)81.0%0-shotEveryQuery: Zero-Shot Clinical Prediction via Task-Conditioned Pretraining
Source quote
L96: 58.0% on AMC, all significantly above chance (Wilcoxon signed-rank p < 10−4). It achieves mean AUCs of 81.0%,
2026Learned latent compression (k=8, l=4) ablationAUPRC0.45990-shot · modalities=EHR+clinical-notes · compression=latent (k=8, l=4) · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L128: Table~\ref{tab:latent_compression} reports a compression ablation in a bimodal EHR + clinical notes model on ICU mortality. Mean pooling improves AUROC over no compression but slightly lowers AUPRC and F1, whereas best latent compression configuration improves all three. Sweeping k \in \{8, 16\} and l \in \{1, 2, 4\}, we select k{=}8, l{=}4, which gives the best AUPRC (0.4599) and competitive AUROC; we adopt it for all subsequent experiments. We note that no single setting dominates across all three metrics, so this choice prioritises AUPRC given the class imbalance of the mortality task.
2026Zero-shot (Qwen2.5-7B) baselineAUROC0.70000-shot · params=7B · backbone=Qwen2.5-7B · task-detail=in-hospital mortalityCounterfactual Self-Evolving Agents for Evidence-Grounded Reasoning
Source quote
L1233: \multirow{3}{*}{MIMIC-IV / IHM} │ \multirow{3}{*}{AUROC} │ Qwen2.5-7B │ 0.7000 │ -- │ -- │ 0.7235 │ 0.7553
2026BioMedBERT clinical-notes model baselineAUROC0.87510-shot · modalities=EHR+clinical-notes · notes-encoder=BioMedBERT · encoder-training=frozen · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L115: \checkmark │ × │ × │ \checkmark │ BioMedBERT \cite{pubmedbert} │ 0.8751 │ 0.4599 │ 0.7107
2026BioMedBERT clinical-notes model baselineAUPRC0.45990-shot · modalities=EHR+clinical-notes · notes-encoder=BioMedBERT · encoder-training=frozen · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L115: \checkmark │ × │ × │ \checkmark │ BioMedBERT \cite{pubmedbert} │ 0.8751 │ 0.4599 │ 0.7107
2026EHR-only baseline baselineAUROC0.86510-shot · modalities=EHR-only · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L131: Table~\ref{tab:modality_encoder_results} evaluates pretrained encoder choice in bimodal settings on ICU mortality, with the EHR-only baseline at 0.8651/0.4561/0.7182 (AUROC/AUPRC/F1). Adding an auxiliary modality does not uniformly improve over this baseline: CXR with either encoder performs below the baseline across all three metrics; ECG with CSFM \cite{gu2026cardiac} improves AUROC (0.8703 vs.\ 0.8651) but lowers AUPRC and F1; clinical notes with BioMedBERT \cite{pubmedbert} is the only configuration to exceed the baseline on both AUROC and AUPRC (0.8751/0.4599), while still trailing on F1. Encoder choice nonetheless has a clear within-modality effect: BioMedCLIP \cite{zhang2023biomedclip} outperforms ViT-MAE \cite{he2022mae} on CXR; CSFM outperforms ECG-FM \cite{mckeen2025ecg} on ECG with a notable AUPRC gap (0.426 vs.\ 0.407); and BioMedBERT substantially outperforms BERT \cite{devlin2019bert} on notes across all metrics. For CXR and notes, the advantage comes from domain-adapted pretraining over general-purpose models; for ECG, CSFM benefits from training on a larger and more diverse cardiac corpus. The unified model conditioned on all three modalities (Table~\ref{tab:modality_encoder_results}, final row; BioMedCLIP for CXR, CSFM for ECG, and BioMedBERT for notes) also fails to surpass the EHR-only baseline, indicating that simply combining modalities does not yield additive gains.
2026EHR-only baseline baselineAUPRC0.45610-shot · modalities=EHR-only · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L131: Table~\ref{tab:modality_encoder_results} evaluates pretrained encoder choice in bimodal settings on ICU mortality, with the EHR-only baseline at 0.8651/0.4561/0.7182 (AUROC/AUPRC/F1). Adding an auxiliary modality does not uniformly improve over this baseline: CXR with either encoder performs below the baseline across all three metrics; ECG with CSFM \cite{gu2026cardiac} improves AUROC (0.8703 vs.\ 0.8651) but lowers AUPRC and F1; clinical notes with BioMedBERT \cite{pubmedbert} is the only configuration to exceed the baseline on both AUROC and AUPRC (0.8751/0.4599), while still trailing on F1. Encoder choice nonetheless has a clear within-modality effect: BioMedCLIP \cite{zhang2023biomedclip} outperforms ViT-MAE \cite{he2022mae} on CXR; CSFM outperforms ECG-FM \cite{mckeen2025ecg} on ECG with a notable AUPRC gap (0.426 vs.\ 0.407); and BioMedBERT substantially outperforms BERT \cite{devlin2019bert} on notes across all metrics. For CXR and notes, the advantage comes from domain-adapted pretraining over general-purpose models; for ECG, CSFM benefits from training on a larger and more diverse cardiac corpus. The unified model conditioned on all three modalities (Table~\ref{tab:modality_encoder_results}, final row; BioMedCLIP for CXR, CSFM for ECG, and BioMedBERT for notes) also fails to surpass the EHR-only baseline, indicating that simply combining modalities does not yield additive gains.
2025Qwen3-32B (Qwen row; no-thinking, full unquantized) baselineAUPRC0.58490-shot · model=Qwen3-32B · params=32B · quantization=unquantized · thinking-mode=no-thinkingStable Prediction of Adverse Events in Medical Time-Series Data
Source quote
L535: Qwen │ 0.8608 │ 0.5849 │ 0.5786 │ 0.3035 │ 1.6934
2025Qwen3-32B (Qwen row; no-thinking, full unquantized) baselineStability0.30350-shot · model=Qwen3-32B · params=32B · quantization=unquantized · thinking-mode=no-thinkingStable Prediction of Adverse Events in Medical Time-Series Data
Source quote
L535: Qwen │ 0.8608 │ 0.5849 │ 0.5786 │ 0.3035 │ 1.6934
2024CARER proposedF1-score70.210-shot · source-dataset=MIMIC-IIICARER - ClinicAl Reasoning-Enhanced Representation for Temporal Health Risk Prediction
Source quote
L439: F1-score of 70.21, significantly outperforming the second-best baseline, MedHMP (68.04).
2024Zero-shot (Gemma-7b-it), preprocessed proposedSpecificity (Results (Patient))0.9892%0-shot · params=7b · backbone=Gemma-7b-it · preprocessing=preprocessedA Novel Compact LLM Framework for Local, High-Privacy EHR Data Applications
Source quote
L203: \multirow{2}{*}{Zero-shot} │ Preprocessed │ {0.9892} │ {0.9889}
2024Zero-shot (Gemma-7b-it), no preprocessing proposedSpecificity (Results (Patient))0.9997%0-shot · params=7b · backbone=Gemma-7b-it · preprocessing=noneA Novel Compact LLM Framework for Local, High-Privacy EHR Data Applications
Source quote
L204: No preprocessing │ 0.9997 │ 0.9998
2024MedHMP baselineF1-score68.040-shot · source-dataset=MIMIC-IIICARER - ClinicAl Reasoning-Enhanced Representation for Temporal Health Risk Prediction
Source quote
L439: F1-score of 70.21, significantly outperforming the second-best baseline, MedHMP (68.04).
2024GPT-4, visit-wise baselineAUROC57.620-shot · input-format=visit-wisePrompting Large Language Models for Zero-Shot Clinical Prediction with Structured Longitudinal Electronic Health Record Data
Source quote
L121: Visit-wise │ 57.94 │ 58.71 │ 57.62 │ 19.21
2023GPT-4 baselineF10.9640-shot · prompt=4Large Language Models in Medical Term Classification and Unexpected Misalignment Between Response and Reasoning
Source quote
L149: 0.964
2023GPT-3.5 Turbo baselineF10.5530-shot · prompt=4Large Language Models in Medical Term Classification and Unexpected Misalignment Between Response and Reasoning
Source quote
L121: 0.553