MIMIC-IV

123 papers · 397 extracted observations · mortality prediction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.70.70.80.8202420252027MEDS-Tab: 0.811 (2024)Fair model g-\theta (fair): 0.723 (2024)Performance-optimized predictive model g-\theta (lg): 0.746 (2024)GAT-guided agent-discovered expression: 0.676 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 41 of 41 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Qwen3-4B (Mech) proposedMacro-F10.51params=4B · backbone=Qwen3-4BCharacterize Then Distill: Mechanistic Reasoning in Large Output Spaces
Source quote
L997: \gain{0.51}{0.12}
2026MedCoRAG proposedF1-score79.12%split: test · params=8B · subset=13 hepatic disease classes · teacher=Qwen3-Max · backbone=Llama-3.1-8B-InstructMedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty Consensus
Source quote
L285: MedCoRAG │ 81.32 │ 79.18 │ 79.12 │ 78.99
2026Calibrated XGBoost (after age-matched resampling) proposedF1 score0.8108age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L480: prior to age-matched resampling, compared to a 0.8108 F1
2026Calibrated XGBoost (age-matched, 20-seed average) proposedF1 score0.8062split: test · age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L671: fier achieved an average F1 score of 0.8062 with a 95% con-
2026MSAM proposedF10.659inputs=diagnoses and procedures · patient-subset=at least two visits · medication-restrictions=with molecular restrictionsLearning Collective Medication Effects via Multi-level Abstraction for Medication Recommendation
Source quote
L322: MSAM │ 0.502/0.503 │ 0.762/0.762 │ 0.657/0.659
2026LONGINUS proposedMicro-F1.597training-freeRethinking Next-Visit Diagnosis Prediction Beyond Aggregate Metrics: Retrieval--Memory Multi-Agent Adjudication
Source quote
L1233: .597†
2026LONGINUS (Gemini-3.1-Flash-Lite) proposedMicro-F1.583training-freeRethinking Next-Visit Diagnosis Prediction Beyond Aggregate Metrics: Retrieval--Memory Multi-Agent Adjudication
Source quote
L1259: margins are smaller in aggregate metrics (e.g., .583
2026TRACER (table label: Ours) proposedMacro F10.7942Readmission within 15 days after discharge; positive-label proportion 48.84%. Patients …Trajectory-Aware Clinical Risk Prediction via Severity-Grounded Knowledge Graphs and Retrieval-Augmented Generation
Source quote
L611: Ours │ 0.8938 │ 0.8830 │ 0.7722 │ 0.9688 │ 0.7949 │ 0.7942 │ 0.8752 │ 0.7183
2026PACE-RAG proposedF1 score47.22%split: test · params=8B · backbone=Llama-3.1-8BPACE-RAG: Patient-Aware Contextual and Evidence-Constrained RAG for Clinical Drug Recommendation
Source quote
L22: Evaluated on a Parkinson’s cohort and the MIMIC-IV benchmark using Llama-3.1-8B and Qwen3-8B, PACE-RAG achieved state-of-the-art performance, reaching F1 scores of 80.84% and 47.22%, respectively.
2026MedCoRAG w/o MA (without Multi-Agent deliberation) ablationF1-score69.70%split: test · subset=13 hepatic disease classes · component=without Multi-Agent deliberationMedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty Consensus
Source quote
L345: w/o MA │ 76.30 │ 69.72 │ 69.70 │ 69.14
2026DeepSeek-V3.1-Think baselineF1-score77.61%split: test · subset=13 hepatic disease classes · backbone=DeepSeek-V3.1-ThinkMedCoRAG: Interpretable Hepatology Diagnosis via Hybrid Evidence Retrieval and Multispecialty Consensus
Source quote
L267: DeepSeek-V3.1-Think \cite{deepseekai2024deepseekv3technicalreport} │ 79.59 │ 76.98 │ 77.61 │ 77.05
2026JEV (v1.14.0), Batch baselinemacro-F10.807split: testCan JEV Support Clinical Trial Criteria Assessment?
Source quote
L17: macro-F1 scores on TrialGPT (0.652 vs. 0.660) and MIMIC-IV (0.807 vs. 0.814), whereas
2026Qwen Flash, Batch baselinemacro-F10.814split: testCan JEV Support Clinical Trial Criteria Assessment?
Source quote
L17: macro-F1 scores on TrialGPT (0.652 vs. 0.660) and MIMIC-IV (0.807 vs. 0.814), whereas
2026JEV (v1.14.0), Single baselinemacro-F10.808split: testCan JEV Support Clinical Trial Criteria Assessment?
Source quote
L500: 0.808
2026Qwen Flash, Single baselinemacro-F10.732split: testCan JEV Support Clinical Trial Criteria Assessment?
Source quote
L514: 0.732
2026Logistic Regression (after age-matched resampling) baselineF1 score0.7816age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L444: 0.7816
2026Random Forest (after age-matched resampling) baselineF1 score0.7981age-matched-cohortMultidimensional Suicide Risk Assessment with Machine Learning using Electronic Health Records
Source quote
L456: 0.7981
2026Random Forest baselineF1-score (F1)0.645split: test · features=LACE-only (4 variables) · train-test-split=80/20From Prediction to Structure: Causal Discovery for 30-Day Readmission Prediction
Source quote
L72: 0.645
2026Random Forest baselineF1-score (F1)0.836split: test · features=all 50 EHR features · train-test-split=80/20From Prediction to Structure: Causal Discovery for 30-Day Readmission Prediction
Source quote
L113: Forest achieves the strongest results with F1=0.836 and
2025EHR2Path Outcome-Oriented Fine-Tuning (E2P-FT-O) proposedF10.45fine-tunedFrom EHRs to Patient Pathways: Scalable Modeling of Longitudinal Health Trajectories with LLMs
Source quote
L312: \metricci{0.45}{0.41,0.48}
2025HiRef proposedF10.6500In-distribution performance, general settings.HiRef: Leveraging Hierarchical Ontology and Network Refinement for Robust Medication Recommendation
Source quote
L330: As shown in Table~\ref{tab:main}, HiRef~ surpasses all baseline models on MIMIC-IV with a Jaccard score of 0.4989, PRAUC of 0.7592, and F1 score of 0.6500, while achieving superior performance compared to the baseline models on MIMIC-III. This demonstrates its overall effectiveness in recommending medications that align with real-world clinical practices. To assess the contribution of each component, we conducted ablation studies with three variants: i) HiRef~w/o hie removes the hierarchical ontology encoder, ii) HiRef~w/o co excludes the co-occurrence graph encoder, and iii) HiRef~w/o fus replaces the convex combination gate with a simple average of the component outputs. The ablation results indicate that all modules are essential for overall performance. Notably, removing the co-occurrence graph encoder (HiRef~w/o co) exhibits the most significant performance drop, underscoring the importance of capturing non-spurious, data-driven associations critical for accurate medication recommendation. The performance decline observed in removing hierarchical ontology encoder (HiRef~w/o hie) highlights the value of enriching entity representations with hierarchical semantic information, thereby improving robustness and generalization. Meanwhile, although removing adaptive gate (HiRef~w/o fus) results in only a small performance drop, it still demonstrates the benefit of adaptive fusion of the outputs from different modules rather than treating them equally.
2025Count baselineF10.600all-shotCross-Representation Benchmarking in Time-Series Electronic Health Records for Clinical Outcome Prediction
Source quote
L112: The effectiveness of pretrained models such as CLMBR is limited to the few-shot scenario. On MIMIC-IV, the Count model outperforms CLMBR in ICU phenotyping (F1 = 0.600 vs. 0.493). In contrast, CLMBR shows clear benefits in few-shot settings, as in EHRSHOT 30-day readmission (F1 = 0.335 vs. 0.266 for Count). These results suggest that a pretrained model is useful when data are scarce, but its advantage diminishes with sufficient training data.
2025CLMBR baselineF10.493all-shotCross-Representation Benchmarking in Time-Series Electronic Health Records for Clinical Outcome Prediction
Source quote
L112: The effectiveness of pretrained models such as CLMBR is limited to the few-shot scenario. On MIMIC-IV, the Count model outperforms CLMBR in ICU phenotyping (F1 = 0.600 vs. 0.493). In contrast, CLMBR shows clear benefits in few-shot settings, as in EHRSHOT 30-day readmission (F1 = 0.335 vs. 0.266 for Count). These results suggest that a pretrained model is useful when data are scarce, but its advantage diminishes with sufficient training data.
2025MEME baselineF10.42MIMIC-IV retrospective outcome-task evaluation; 95% confidence interval reported.From EHRs to Patient Pathways: Scalable Modeling of Longitudinal Health Trajectories with LLMs
Source quote
L309: \metricci{0.42}{0.37,0.48}
2025GPT-5-mini baselineaverage F172.4subset=curated 1,000 notes · evaluation=sentence-level and freetext segmentationCNSight: Evaluation of Clinical Note Segmentation Tools
Source quote
L4: Clinical notes are often stored in unstructured or semi-structured formats after extraction from electronic medical record (EMR) systems, which complicates their use for secondary analysis and downstream clinical applications. Reliable identification of section boundaries is a key step toward structuring these notes, as sections such as history of present illness, medications, and discharge instructions each provide distinct clinical contexts. In this work, we evaluate rule-based baselines, domain-specific transformer models, and large language models for clinical note segmentation using a curated dataset of 1,000 notes from MIMIC-IV. Our experiments show that large API-based models achieve the best overall performance, with GPT-5-mini reaching a best average F1 of 72.4 across sentence-level and freetext segmentation. Lightweight baselines remain competitive on structured sentence-level tasks but falter on unstructured freetext. Our results provide guidance for method selection and lay the groundwork for downstream tasks such as information extraction, cohort identification, and automated summarization.
2024MulT-EHR (RMDL, all four tasks) proposedF168.45training-tasks=readmission, mortality, drug recommendation, length-of-stayMulti-task heterogeneous graph learning on electronic health records
Source quote
L540: RMDL │ 71.33 │ 70.61 │ 69.86 │ 68.74 │ 70.02 │ 68.45
2024KARE (ours), fine-tuned Mistral-7B-Instruct-v0.3 proposedMacro F173.8split: test · fine-tuned · runs=3 · params=7B · backbone=Mistral-7B-Instruct-v0.3 · readmission-window=15 daysReasoning-Enhanced Healthcare Predictions with Knowledge Graph Community Retrieval
Source quote
L281: \quad KARE (ours) │ 94.1 │ 90.4 │ 73.2 │ 99.8 │ 73.9 │ 73.8 │ 85.6 │ 63.7
2024CARER proposed non-standard sliceweighted F1 (table label: F1)77.80split: test · modalities=clinical-notes-excludedCARER - ClinicAl Reasoning-Enhanced Representation for Temporal Health Risk Prediction
Source quote
L384: 77.80
2024CARER proposedF1-score70.210-shot · source-dataset=MIMIC-IIICARER - ClinicAl Reasoning-Enhanced Representation for Temporal Health Risk Prediction
Source quote
L439: F1-score of 70.21, significantly outperforming the second-best baseline, MedHMP (68.04).
2024MedHMP baseline non-standard sliceweighted F1 (table label: F1)75.53split: test · modalities=clinical-notes-excludedCARER - ClinicAl Reasoning-Enhanced Representation for Temporal Health Risk Prediction
Source quote
L369: 75.53
2024MedHMP baselineF1-score68.040-shot · source-dataset=MIMIC-IIICARER - ClinicAl Reasoning-Enhanced Representation for Temporal Health Risk Prediction
Source quote
L439: F1-score of 70.21, significantly outperforming the second-best baseline, MedHMP (68.04).
2024GPT-3.5 baselineCoPHE F116.72GPT-3.5 coding evaluation on real discharge summaries, without the prompted concept des…Can GPT-3.5 Generate and Code Discharge Summaries?
Source quote
L222: GPT-3.5 Real │ 9.46 │ 33.51 │ 14.76 │ 10.59 │ 44.87 │ 17.13 │ 10.30 │ 44.33 │ 16.72
2024FLAN-T5 baselineF171.92split: val · fine-tuned · subset=25%-training-data · evaluation=5-fold-cross-validationAre Clinical T5 Models Better for Clinical Text?
Source quote
L1552: 71.92
2024MIMIC-T5 baselineF164.44split: val · fine-tuned · subset=25%-training-data · evaluation=5-fold-cross-validationAre Clinical T5 Models Better for Clinical Text?
Source quote
L1553: 64.44
2023GPT-4 reasoning-based predictions proposedF10.788split: test · prompt=1 · correction=after rationalization correction · test-cases=87Large Language Models in Medical Term Classification and Unexpected Misalignment Between Response and Reasoning
Source quote
L317: 0.788
2023Self-verified extraction (GPT-4) proposedF10.53model=GPT-4 · subset=patient discharge summaries · code-system=ICD-10Self-verification improves few-shot clinical information extraction
Source quote
L288: MIMIC-IV ICD10, self-verified │ 0.53\err{0.002}
2023DRG-LLaMA-7B proposedmacro-averaged F1 score0.327fine-tuned · params=7B · tuning=LoRA · backbone=LLaMA-7B · max_input_length=512 tokensDRG-LLaMA : tuning LLaMA model to predict diagnosis-related group for hospitalized patients
Source quote
L4: In the U.S. inpatient payment system, the Diagnosis-Related Group (DRG) is pivotal, but its assignment process is inefficient. The study introduces \texttt{DRG-LLaMA} , an advanced large language model (LLM) fine-tuned on clinical notes to enhance DRGs assignment. Utilizing LLaMA as the foundational model and optimizing it through Low-Rank Adaptation (LoRA) on 236,192 MIMIC-IV discharge summaries, our \texttt{DRG-LLaMA} -7B model exhibited a noteworthy macro-averaged F1 score of 0.327, a top-1 prediction accuracy of 52.0%, and a macro-averaged Area Under the Curve (AUC) of 0.986, with a maximum input token length of 512. This model surpassed the performance of prior leading models in DRG prediction, showing a relative improvement of 40.3% and 35.7% in macro-averaged F1 score compared to ClinicalBERT and CAML, respectively. Applied to base DRG and complication or comorbidity (CC)/major complication or comorbidity (MCC) prediction, \texttt{DRG-LLaMA} achieved a top-1 prediction accuracy of 67.8% and 67.5%, respectively. Additionally, our findings indicate that \texttt{DRG-LLaMA} ’s performance correlates with increased model parameters and input context lengths.
2023GPT-4 baselineF10.9640-shot · prompt=4Large Language Models in Medical Term Classification and Unexpected Misalignment Between Response and Reasoning
Source quote
L149: 0.964
2023GPT-3.5 Turbo baselineF10.5530-shot · prompt=4Large Language Models in Medical Term Classification and Unexpected Misalignment Between Response and Reasoning
Source quote
L121: 0.553
2023GPT-4 actual predictions baselineF10.667split: test · prompt=1 · correction=before rationalization correction · test-cases=87Large Language Models in Medical Term Classification and Unexpected Misalignment Between Response and Reasoning
Source quote
L313: 0.667
2023Original extraction (GPT-4) baselineF10.49model=GPT-4 · subset=patient discharge summaries · code-system=ICD-10Self-verification improves few-shot clinical information extraction
Source quote
L287: MIMIC-IV ICD10, original │ 0.49\err{0.02}