MIMIC-IV
123 papers · 397 extracted observations · mortality prediction · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MEDS-Tab SOTA frontier | 0.811 | 2024-01-01 | Result for MIMIC-IV; the table reports paired results in MIMIC-IV/Columbia order. Eva… | MEDS Decentralized, Extensible Validation (MEDS-DEV) Benchmark: Establishing Reproducibility and Comparability in ML for HealthSource quote0.811/0.761 |
| 2 | Performance-optimized predictive model g-\theta (lg) (+1 variant) | 0.746 | 2024-04-01 | groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349 · MIMIC-IV cohort after preprocessing (N=9,349); race groups White vs Non-White; 5-fold… | Explainable AI for Fair Sepsis Mortality Predictive ModelSource quoteAUC │ ACC │ TPR-Diff │ FPR-Diff │ EOD (\mathcal{E}) g-\theta (lg)(X) │ 0.746 │ 0.675 │ 0.071 │ 0.064 │ 0.068 |
| 3 | GAT-guided agent-discovered expression | 0.676 | 2026-10-01 | External validation; systemic lupus erythematosus (SLE) disease cell. The table repor… | Agentic discovery of blood biomarker from distilled private health recordsSource quote0.516 [0.501, 0.563] / 0.676 [0.633, 0.723] |
Regimefine-tuned (22)0-shot (19)age-matched-cohort (7)offline-rl (6)black-box (6)out-of-distribution (4)
Showing 4 of 4 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | Distilled-summary models proposed | AUROC | 0.92 | fine-tuned · compression=about 20x smaller than original notes | DistillNote: LLM-based clinical note summaries improve heart failure diagnosisSource quoteL10: Results: Summaries generated by LLMs maintained a strong level of heart failure diagnostic signal despite substantial compression. Models trained on the most condensed summaries (about 20 times smaller) achieved an AUROC of 0.92, compared to 0.94 with the original note baseline (97% retention). Functional evaluation provided a new lens for medical summary assessment, emphasizing clinical utility as a key dimension of quality. |
| 2025 | Original-note baseline baseline | AUROC | 0.94 | fine-tuned · input=original notes | DistillNote: LLM-based clinical note summaries improve heart failure diagnosisSource quoteL10: Results: Summaries generated by LLMs maintained a strong level of heart failure diagnostic signal despite substantial compression. Models trained on the most condensed summaries (about 20 times smaller) achieved an AUROC of 0.92, compared to 0.94 with the original note baseline (97% retention). Functional evaluation provided a new lens for medical summary assessment, emphasizing clinical utility as a key dimension of quality. |
| 2022 | MedFuse (OPTIMAL) proposed | AUROC | 0.768 | split: test · fine-tuned · variant=OPTIMAL · data-regime=partially-paired · training-data=paired samples and 20% of unimodal samples | MedFuse: Multi-modal fusion with clinical time-series data and chest X-ray imagesSource quoteL201: In Table~\ref{tab:partialresults}, we evaluate our proposed approach with \texttt{MedFuse} as well as early and joint fusion on the partially paired test set. Compared to early fusion, our proposed approach trained with the full (EHR+CXR)-PARTIAL training set achieves a better performance for phenotype classification (0.758 compared to 0.748 AUROC and 0.418 compared to 0.394 AUPRC). It performs comparably with early fusion in the in-hospital mortality prediction task, although early fusion achieves a better AUPRC. Our approach outperforms joint fusion in the in-hospital mortality setting (0.861 compared to 0.841 AUROC and 0.501 compared to 0.482 AUPRC), and performs comparably for phenotype classification. Overall, \texttt{MedFuse} (OPTIMAL), fine-tuned with paired samples and only 10% of uni-modal samples for in-hospital mortality prediction and 20% of uni-modal samples for phenotype classification, achieves the best performance (0.768 AUROC and 0.429 AUPRC for phenotype classification and 0.874 AUROC and 0.567 AUPRC for inhospital mortality prediction). We also performed an ablation study where we varied the percentage of uni-modal samples in the partially paired setting. The results are shown in Appendix~\ref{unimodalpercPARTIAL}. |
| 2022 | MedFuse (OPTIMAL) proposed | AUROC | 0.874 | split: test · fine-tuned · variant=OPTIMAL · data-regime=partially-paired · training-data=paired samples and 10% of unimodal samples | MedFuse: Multi-modal fusion with clinical time-series data and chest X-ray imagesSource quoteL201: In Table~\ref{tab:partialresults}, we evaluate our proposed approach with \texttt{MedFuse} as well as early and joint fusion on the partially paired test set. Compared to early fusion, our proposed approach trained with the full (EHR+CXR)-PARTIAL training set achieves a better performance for phenotype classification (0.758 compared to 0.748 AUROC and 0.418 compared to 0.394 AUPRC). It performs comparably with early fusion in the in-hospital mortality prediction task, although early fusion achieves a better AUPRC. Our approach outperforms joint fusion in the in-hospital mortality setting (0.861 compared to 0.841 AUROC and 0.501 compared to 0.482 AUPRC), and performs comparably for phenotype classification. Overall, \texttt{MedFuse} (OPTIMAL), fine-tuned with paired samples and only 10% of uni-modal samples for in-hospital mortality prediction and 20% of uni-modal samples for phenotype classification, achieves the best performance (0.768 AUROC and 0.429 AUPRC for phenotype classification and 0.874 AUROC and 0.567 AUPRC for inhospital mortality prediction). We also performed an ablation study where we varied the percentage of uni-modal samples in the partially paired setting. The results are shown in Appendix~\ref{unimodalpercPARTIAL}. |