MIMIC-IV
123 papers · 397 extracted observations · mortality prediction · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results matching split=val.
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MEDS-Tab SOTA frontier | 0.811 | 2024-01-01 | Result for MIMIC-IV; the table reports paired results in MIMIC-IV/Columbia order. Eva… | MEDS Decentralized, Extensible Validation (MEDS-DEV) Benchmark: Establishing Reproducibility and Comparability in ML for HealthSource quote0.811/0.761 |
| 2 | Performance-optimized predictive model g-\theta (lg) (+1 variant) | 0.746 | 2024-04-01 | groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349 · MIMIC-IV cohort after preprocessing (N=9,349); race groups White vs Non-White; 5-fold… | Explainable AI for Fair Sepsis Mortality Predictive ModelSource quoteAUC │ ACC │ TPR-Diff │ FPR-Diff │ EOD (\mathcal{E}) g-\theta (lg)(X) │ 0.746 │ 0.675 │ 0.071 │ 0.064 │ 0.068 |
| 3 | GAT-guided agent-discovered expression | 0.676 | 2026-10-01 | External validation; systemic lupus erythematosus (SLE) disease cell. The table repor… | Agentic discovery of blood biomarker from distilled private health recordsSource quote0.516 [0.501, 0.563] / 0.676 [0.633, 0.723] |
Regimefine-tuned (22)0-shot (19)age-matched-cohort (7)offline-rl (6)black-box (6)out-of-distribution (4)
Showing 5 of 5 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | Unified three-modality model (BioMedCLIP for CXR, CSFM for ECG, BioMedBERT for notes) proposed | AUPRC | 0.4330 | 0-shot · modalities=EHR+CXR+ECG+clinical-notes · CXR-encoder=BioMedCLIP · ECG-encoder=CSFM · notes-encoder=BioMedBERT · stochastic-futures=20 | Autoregressive EHR Foundation Models with Multimodal InputsSource quoteL116: \checkmark │ \checkmark │ \checkmark │ \checkmark │ Best per modality │ 0.8460 │ 0.4330 │ 0.6997 |
| 2026 | Learned latent compression (k=8, l=4) ablation | AUPRC | 0.4599 | 0-shot · modalities=EHR+clinical-notes · compression=latent (k=8, l=4) · stochastic-futures=20 | Autoregressive EHR Foundation Models with Multimodal InputsSource quoteL128: Table~\ref{tab:latent_compression} reports a compression ablation in a bimodal EHR + clinical notes model on ICU mortality. Mean pooling improves AUROC over no compression but slightly lowers AUPRC and F1, whereas best latent compression configuration improves all three. Sweeping k \in \{8, 16\} and l \in \{1, 2, 4\}, we select k{=}8, l{=}4, which gives the best AUPRC (0.4599) and competitive AUROC; we adopt it for all subsequent experiments. We note that no single setting dominates across all three metrics, so this choice prioritises AUPRC given the class imbalance of the mortality task. |
| 2026 | BioMedBERT clinical-notes model baseline | AUPRC | 0.4599 | 0-shot · modalities=EHR+clinical-notes · notes-encoder=BioMedBERT · encoder-training=frozen · stochastic-futures=20 | Autoregressive EHR Foundation Models with Multimodal InputsSource quoteL115: \checkmark │ × │ × │ \checkmark │ BioMedBERT \cite{pubmedbert} │ 0.8751 │ 0.4599 │ 0.7107 |
| 2026 | EHR-only baseline baseline | AUPRC | 0.4561 | 0-shot · modalities=EHR-only · stochastic-futures=20 | Autoregressive EHR Foundation Models with Multimodal InputsSource quoteL131: Table~\ref{tab:modality_encoder_results} evaluates pretrained encoder choice in bimodal settings on ICU mortality, with the EHR-only baseline at 0.8651/0.4561/0.7182 (AUROC/AUPRC/F1). Adding an auxiliary modality does not uniformly improve over this baseline: CXR with either encoder performs below the baseline across all three metrics; ECG with CSFM \cite{gu2026cardiac} improves AUROC (0.8703 vs.\ 0.8651) but lowers AUPRC and F1; clinical notes with BioMedBERT \cite{pubmedbert} is the only configuration to exceed the baseline on both AUROC and AUPRC (0.8751/0.4599), while still trailing on F1. Encoder choice nonetheless has a clear within-modality effect: BioMedCLIP \cite{zhang2023biomedclip} outperforms ViT-MAE \cite{he2022mae} on CXR; CSFM outperforms ECG-FM \cite{mckeen2025ecg} on ECG with a notable AUPRC gap (0.426 vs.\ 0.407); and BioMedBERT substantially outperforms BERT \cite{devlin2019bert} on notes across all metrics. For CXR and notes, the advantage comes from domain-adapted pretraining over general-purpose models; for ECG, CSFM benefits from training on a larger and more diverse cardiac corpus. The unified model conditioned on all three modalities (Table~\ref{tab:modality_encoder_results}, final row; BioMedCLIP for CXR, CSFM for ECG, and BioMedBERT for notes) also fails to surpass the EHR-only baseline, indicating that simply combining modalities does not yield additive gains. |
| 2025 | Qwen3-32B (Qwen row; no-thinking, full unquantized) baseline | AUPRC | 0.5849 | 0-shot · model=Qwen3-32B · params=32B · quantization=unquantized · thinking-mode=no-thinking | Stable Prediction of Adverse Events in Medical Time-Series DataSource quoteL535: Qwen │ 0.8608 │ 0.5849 │ 0.5786 │ 0.3035 │ 1.6934 |