MIMIC-IV

123 papers · 397 extracted observations · mortality prediction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.70.70.80.8202420252027MEDS-Tab: 0.811 (2024)Fair model g-\theta (fair): 0.723 (2024)Performance-optimized predictive model g-\theta (lg): 0.746 (2024)GAT-guided agent-discovered expression: 0.676 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 5 of 5 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026Unified three-modality model (BioMedCLIP for CXR, CSFM for ECG, BioMedBERT for notes) proposedAUPRC0.43300-shot · modalities=EHR+CXR+ECG+clinical-notes · CXR-encoder=BioMedCLIP · ECG-encoder=CSFM · notes-encoder=BioMedBERT · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L116: \checkmark │ \checkmark │ \checkmark │ \checkmark │ Best per modality │ 0.8460 │ 0.4330 │ 0.6997
2026Learned latent compression (k=8, l=4) ablationAUPRC0.45990-shot · modalities=EHR+clinical-notes · compression=latent (k=8, l=4) · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L128: Table~\ref{tab:latent_compression} reports a compression ablation in a bimodal EHR + clinical notes model on ICU mortality. Mean pooling improves AUROC over no compression but slightly lowers AUPRC and F1, whereas best latent compression configuration improves all three. Sweeping k \in \{8, 16\} and l \in \{1, 2, 4\}, we select k{=}8, l{=}4, which gives the best AUPRC (0.4599) and competitive AUROC; we adopt it for all subsequent experiments. We note that no single setting dominates across all three metrics, so this choice prioritises AUPRC given the class imbalance of the mortality task.
2026BioMedBERT clinical-notes model baselineAUPRC0.45990-shot · modalities=EHR+clinical-notes · notes-encoder=BioMedBERT · encoder-training=frozen · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L115: \checkmark │ × │ × │ \checkmark │ BioMedBERT \cite{pubmedbert} │ 0.8751 │ 0.4599 │ 0.7107
2026EHR-only baseline baselineAUPRC0.45610-shot · modalities=EHR-only · stochastic-futures=20Autoregressive EHR Foundation Models with Multimodal Inputs
Source quote
L131: Table~\ref{tab:modality_encoder_results} evaluates pretrained encoder choice in bimodal settings on ICU mortality, with the EHR-only baseline at 0.8651/0.4561/0.7182 (AUROC/AUPRC/F1). Adding an auxiliary modality does not uniformly improve over this baseline: CXR with either encoder performs below the baseline across all three metrics; ECG with CSFM \cite{gu2026cardiac} improves AUROC (0.8703 vs.\ 0.8651) but lowers AUPRC and F1; clinical notes with BioMedBERT \cite{pubmedbert} is the only configuration to exceed the baseline on both AUROC and AUPRC (0.8751/0.4599), while still trailing on F1. Encoder choice nonetheless has a clear within-modality effect: BioMedCLIP \cite{zhang2023biomedclip} outperforms ViT-MAE \cite{he2022mae} on CXR; CSFM outperforms ECG-FM \cite{mckeen2025ecg} on ECG with a notable AUPRC gap (0.426 vs.\ 0.407); and BioMedBERT substantially outperforms BERT \cite{devlin2019bert} on notes across all metrics. For CXR and notes, the advantage comes from domain-adapted pretraining over general-purpose models; for ECG, CSFM benefits from training on a larger and more diverse cardiac corpus. The unified model conditioned on all three modalities (Table~\ref{tab:modality_encoder_results}, final row; BioMedCLIP for CXR, CSFM for ECG, and BioMedBERT for notes) also fails to surpass the EHR-only baseline, indicating that simply combining modalities does not yield additive gains.
2025Qwen3-32B (Qwen row; no-thinking, full unquantized) baselineAUPRC0.58490-shot · model=Qwen3-32B · params=32B · quantization=unquantized · thinking-mode=no-thinkingStable Prediction of Adverse Events in Medical Time-Series Data
Source quote
L535: Qwen │ 0.8608 │ 0.5849 │ 0.5786 │ 0.3035 │ 1.6934