MIMIC-IV

123 papers · 397 extracted observations · mortality prediction · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results matching split=val.

0.70.70.80.8202420252027MEDS-Tab: 0.811 (2024)Fair model g-\theta (fair): 0.723 (2024)Performance-optimized predictive model g-\theta (lg): 0.746 (2024)GAT-guided agent-discovered expression: 0.676 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 8 of 8 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2024Performance-optimized predictive model g-\theta (lg) proposedACC (Accuracy)0.675split: val · groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349Explainable AI for Fair Sepsis Mortality Predictive Model
Source quote
L110: AUC │ ACC │ TPR-Diff │ FPR-Diff │ EOD (\mathcal{E}) g-\theta (lg)(X) │ 0.746 │ 0.675 │ 0.071 │ 0.064 │ 0.068
2024Fair model g-\theta (fair) proposedACC (Accuracy)0.637split: val · groups=White vs Non-White · validation=5-fold cross-validation · cohort-size=9349Explainable AI for Fair Sepsis Mortality Predictive Model
Source quote
L111: g-\theta (fair)(X) │ 0.723 │ 0.637 │ 0.002 │ 0.015 │ 0.008
2024pyAKI generated labels proposedOverall AKI-stage accuracy1.0split: valpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024pyAKI generated labels proposedUrine-output (UO) accuracy1.0split: val · criterion=urine-outputpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024pyAKI generated labels proposedRelative serum creatinine (SCr) elevation accuracy1.0split: val · criterion=relative-serum-creatinine-elevationpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024Human labels (senior physicians) baselineOverall AKI-stage accuracy0.9771split: valpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024Human labels (senior physicians) baselineUrine-output (UO) accuracy0.9664split: val · criterion=urine-outputpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.
2024Human labels (senior physicians) baselineRelative serum creatinine (SCr) elevation accuracy0.9996split: val · criterion=relative-serum-creatinine-elevationpyAKI - An Open Source Solution to Automated KDIGO classification
Source quote
L85: An overview of all measured accuracies, categorized by each stage and each criterion of \acrshort{kdigo} classification, after comparing to the labels generated by the senior physicians is depicted in table \ref{tab:aki_and_accuracies}. Overall accuracy was high, both in the labels generated by physicians, as well as the labels generated by the pipeline. Accuracy across \acrshort{kdigo}-stages were also high (human vs. pyAKI): \acrshort{uo} was 0.9664 vs. 1.0 and relative \acrshort{scr} elevation was 0.9996 vs. 1.0. Accuracy for both dialysis-stage and absolute \acrshort{scr} elevation was 1.0 both in human labelling, as well as in labels generated by pyAKI. For overall \acrshort{aki}-stage, accuracy where 0.9771 for human labels and 1.0 for pyAKI generated labels.