MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 9 of 9 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | RAD-DINO image-only configuration proposed | AUROC (macro) | 0.637 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL873: gain 0.025 and 0.027 (AUROC 0.637 and 0.650; RAD-DINO |
| 2026 | RAD-DINO early-fusion configuration proposed | AUROC (macro) | 0.650 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL873: gain 0.025 and 0.027 (AUROC 0.637 and 0.650; RAD-DINO |
| 2026 | RAD-DINO image configuration proposed | F2 (macro) | +0.047 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL877: 0.047 F2 and 0.099 AUROC (p = 0.008 and p = 0.005), and |
| 2026 | RAD-DINO and time-aligned history fusion proposed | AUROC (macro) | 0.766 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL908: patient-separated A/C models in Table IV (0.766 and 0.762; |
| 2026 | RAD-DINO and time-aligned history fusion proposed | AUROC (macro) | 0.762 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL908: patient-separated A/C models in Table IV (0.766 and 0.762; |
| 2026 | Selected EHR-only configuration proposed | F2 (macro) | 0.373 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL946: (0.373) by 0.065 F2 and 0.142 AUROC and the 11 pathology |
| 2026 | RAD-DINO image-only configuration proposed | AUROC (macro) | 0.722 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL945: (0.438, AUROC 0.722) exceeds the released EHR variables |
| 2026 | Prior-diagnosis rule baseline | F2 (macro) | 0.385 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL895: reaches 0.385 macro F2 under P4 and 0.337 under P4-C, above |
| 2026 | Prior-diagnosis rule baseline | F2 (macro) | 0.337 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL895: reaches 0.385 macro F2 under P4 and 0.337 under P4-C, above |