MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 150 of 775 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | MedMO (variant not specified) proposed | CIDEr | 140.0 | Medical report generation; the cited prose does not specify the model variant or evalua… | MedMO: Grounding and Understanding Multimodal Large Language Model for Medical ImagesSource quoteL276: On MIMIC-CXR, the most widely-used benchmark for chest X-ray report generation, our model achieves outstanding results with a CIDEr score of 140.0 and ROUGE-L of 31.7%, substantially outperforming strong medical baselines including Fleming-VL-8B (132.5, 35.7%) and Lingshu-7B (109.4, 30.8%). While Fleming-VL-8B achieves a higher ROUGE-L, our superior CIDEr score indicates better semantic coherence and clinical relevance. Most notably, the RaTE score of 57.1% and remarkable Semb score of 50.0% demonstrate that MedMO generates reports with high clinical accuracy and semantic fidelity. |
| 2026 | RN50(KAN) + KAN-Map (K) proposed | IoU | 0.069 | backbone=ResNet-50 with KAN head · backbone_status=pretrained and frozen · explanation_method=KAN-Map | KANEx: Translating Kolmogorov-Arnold Networks' Interpretability to Medical ExplainabilitySource quoteL144: 0.060 │ -- │ 0.069 |
| 2026 | RN50(rKAN) + KAN-Map (K) proposed | IoU | 0.076 | backbone=ResNet-50 with RationalKAN head · backbone_status=pretrained and frozen · explanation_method=KAN-Map | KANEx: Translating Kolmogorov-Arnold Networks' Interpretability to Medical ExplainabilitySource quoteL150: 0.061 │ -- │ 0.076 |
| 2026 | RN50(KAN) + KAN-Map (K) proposed | Faithfulness | 9.116 | backbone=ResNet-50 with KAN head · backbone_status=pretrained and frozen · explanation_method=KAN-Map | KANEx: Translating Kolmogorov-Arnold Networks' Interpretability to Medical ExplainabilitySource quoteL147: 3.893 │ -- │ 9.116 |
| 2026 | DRRG proposed | BLEU-4 | 0.210 | denoising-steps=72 · sequence-length=100 | DRRG: A Discrete Diffusion Framework for Radiology Report GenerationSource quoteL355: NLG Metrics: The NLG results on MIMIC-CXR and CheXpert Plus are reported in Table~\ref{tab:mimic_nlg} and Table~\ref{tab:chex_plus}. On MIMIC-CXR, DRRG achieves the best performance on BLEU-2, BLEU-3, BLEU-4, and ROUGE-L, with scores of 0.332, 0.259, 0.210, and 0.343, respectively. It also obtains the second-best BLEU-1 score of 0.452, slightly behind REVTAF-RRG~\cite{zhou2025learnable}. Compared with recent LLM-based RRG methods, DRRG achieves stronger NLG performance with a substantially smaller 0.6B text decoder, whereas the listed LLM-based competitors use text decoders with 7B or more parameters. On CheXpert Plus, DRRG achieves the best BLEU-4 score and a competitive ROUGE-L of 0.265. These results demonstrate the effectiveness of DRRG, suggesting that DLLMs provide a strong alternative to conventional AR-based RRG models. |
| 2026 | ConRad (sentence-level) proposed | ECE | 0.239 | granularity=sentence-level | Calibrated Confidence Expression for Radiology Report GenerationSource quoteL103: ConRad │ 0.239 {[0.225, 0.253]} │ 0.633 {[0.620, 0.647]} │ 0.262 {[0.250, 0.274]} |
| 2026 | ConRad (sentence-level) proposed | AUROC | 0.633 | granularity=sentence-level | Calibrated Confidence Expression for Radiology Report GenerationSource quoteL103: ConRad │ 0.239 {[0.225, 0.253]} │ 0.633 {[0.620, 0.647]} │ 0.262 {[0.250, 0.274]} |
| 2026 | ConRad (sentence-level) proposed | GREEN | 0.262 | granularity=sentence-level | Calibrated Confidence Expression for Radiology Report GenerationSource quoteL103: ConRad │ 0.239 {[0.225, 0.253]} │ 0.633 {[0.620, 0.647]} │ 0.262 {[0.250, 0.274]} |
| 2026 | CLEAR (MedGemma, Blur) proposed | AUPRC | 90.23% | split: test | Visually Irrelevant Hallucinations in Medical Vision-Language ModelsSource quoteL37: CXR, CLEAR improves AUPRC from 85.10% to 90.23%. Its |
| 2026 | RAD-DINO image-only configuration proposed | AUROC (macro) | 0.637 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL873: gain 0.025 and 0.027 (AUROC 0.637 and 0.650; RAD-DINO |
| 2026 | RAD-DINO early-fusion configuration proposed | AUROC (macro) | 0.650 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL873: gain 0.025 and 0.027 (AUROC 0.637 and 0.650; RAD-DINO |
| 2026 | RAD-DINO image configuration proposed | F2 (macro) | +0.047 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL877: 0.047 F2 and 0.099 AUROC (p = 0.008 and p = 0.005), and |
| 2026 | RAD-DINO and time-aligned history fusion proposed | AUROC (macro) | 0.766 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL908: patient-separated A/C models in Table IV (0.766 and 0.762; |
| 2026 | RAD-DINO and time-aligned history fusion proposed | AUROC (macro) | 0.762 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL908: patient-separated A/C models in Table IV (0.766 and 0.762; |
| 2026 | Selected EHR-only configuration proposed | F2 (macro) | 0.394 | split: record | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL934: over the patient split (0.394 vs. 0.373), and the margins of |
| 2026 | Selected EHR-only configuration proposed | F2 (macro) | 0.373 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL946: (0.373) by 0.065 F2 and 0.142 AUROC and the 11 pathology |
| 2026 | RAD-DINO image-only configuration proposed | AUROC (macro) | 0.722 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL945: (0.438, AUROC 0.722) exceeds the released EHR variables |
| 2026 | FairLLaVA-All proposed | Age-group RadGraph-F1 fairness gap | 5.60 | Age-group gap; evaluation aggregates over subgroups of the other demographic attributes… | FairLLaVA: Fairness-Aware Parameter-Efficient Fine-Tuning for Large Vision-Language AssistantsSource quoteL680: 0.59 │ 1.01 │ 5.60 │ 12.29 |
| 2026 | FairLLaVA-All proposed | Overall GREEN | 34.32 | Overall performance score; higher is better. | FairLLaVA: Fairness-Aware Parameter-Efficient Fine-Tuning for Large Vision-Language AssistantsSource quoteL682: 34.85 │ 13.92 │ 28.52 │ 34.32 |
| 2026 | LePaX proposed | BLEU-4 | 0.253 | Report-generation evaluation; the paper reports BLEU-4 / METEOR / ROUGE in that order. | Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report GenerationSource quoteL341: On MIMIC-CXR, it achieves BLEU-4 / METEOR / ROUGE scores of 0.253 / 0.336 / 0.380, surpassing previous encoder–decoder, transformer, and LLM-based methods. |
| 2026 | LePaX proposed | RadGraph F1 (RG_F1) | 0.346 | Clinical metric evaluation on MIMIC-CXR. | Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report GenerationSource quoteL439: 0.346 |
| 2026 | LePaX (Ours-1920) proposed | Vision Tokens | 128 tokens | resolution=up to 1920×1920 | Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report GenerationSource quoteL591: 128 │ 2.7s │ 46GB |
| 2026 | Graph-Supervised Hierarchical Clinical Alignment (full model; 3B, ablation configuration 10) proposed | B@4 | 0.143 | params=3B · backbone=3B · alignment-components=ICSM, DCSR, ICDM, DCNR, IMSC | Graph-Supervised Hierarchical Clinical Alignment for Radiology Report Generation with Large Language ModelsSource quoteL476: 10 │ 3B │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 0.427 │ 0.143 │ 0.167 │ 0.305 │ 1.145 |
| 2026 | IMT-CXR proposed | BL-1 | 38.6 | split: test | A unified multi-task framework enables interpretable chest radiograph analysisSource quoteL688: Ours │ 38.6 │ 13.1 │ 16.7 │ 27.5 │ 42.8 │ 31.5 │ 33.1 |
| 2026 | CompDiff proposed | FID | 64.3 | split: test · seeds=3 · training_steps=up to 30000 | CompDiff: Hierarchical Compositional Diffusion for Fair and Zero-Shot Intersectional Medical Image GenerationSource quoteL131: Table~\ref{tab:overall_and_equity} compares CompDiff against baselines across chest X-ray and fundus modalities. CompDiff achieves the best FID on both modalities (64.3 chest, 54.6 fundus). While FairDiffusion achieves slightly lower FID-RadImageNet on chest (6.2 vs 6.8), CompDiff outperforms on disease classification AUROC (0.82 vs 0.74), indicating better clinical feature alignment. MS-SSIM values remain in the acceptable range (0.25--0.75) for all models, confirming neither overfitting nor generation failure. Sex accuracy remains near-perfect across all methods. Slightly reduced race accuracy and increased age RMSE are expected trade-offs from HCN conditioning, offset by improved subgroup-level fairness below. |
| 2026 | FINO proposed | AUROC | 81.8 | split: test · params=2.7M label-supervised · subset=IID; 14 pathology labels · backbone=DINOv3 ViT-L/16 | Who Needs Labels? Adapting Vision Foundation Models With the Metadata You Already HaveSource quoteL201: \bf FINO (ours) │ 2.7M │ {\color{cyan}\Snow} │ {\bf 61.2} │ {\bf 53.1} │ \bf{52.9} │ {\bf 81.8} |
| 2026 | Bayesian Pairwise Merging (BPM) proposed non-standard slice | Macro decided win rate against uniform merge (RS) | 91.7% | split: test · feedback-budget=100 | The Missing Coefficients: Bayesian Pairwise Merging for Model PersonalizationSource quoteL321: RS │ \mrbhldiff{91.7}{50}\,\mrbci{90.3, 93.1} │ \mrbhldiff{88.4}{50}\,\mrbci{86.2, 90.4} │ \mrbhldiff{77.1}{50}\,\mrbci{74.7, 79.3} │ \mrbhldiff{78.7}{50}\,\mrbci{76.6, 80.7} │ \mrbhldiff{64.3}{50}\,\mrbci{62.5, 66.1} │ \mrbhldiff{76.1}{50}\,\mrbci{74.4, 77.8} |
| 2026 | Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposed | AUPRC | 87.78% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL226: S3: Case + Evidence + Claim │ 97.43 │ 87.78 │ 78.72 │ 92.03 │ 0.060 |
| 2026 | Evidence-only baseline (S2: Evidence + Claim; shared ModernBERT-large verifier) proposed | AUPRC | 35.11% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL225: S2: Evidence + Claim │ 82.63 │ 35.11 │ 62.79 │ 87.53 │ 0.255 |
| 2026 | Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposed | AUROC | 97.43% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL226: S3: Case + Evidence + Claim │ 97.43 │ 87.78 │ 78.72 │ 92.03 │ 0.060 |
| 2026 | Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposed | AUROC | 55.62% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL1297: AUROC │ 97.43 ± 0.27 [97--98] │ 97.24 ± 0.33 [97--98] │ 55.62 ± 1.50 [53--59] |
| 2026 | Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposed | AUPRC | 74.18% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL1298: AUPRC │ 87.78 ± 1.56 [85--91] │ 74.18 ± 3.20 [68--80] │ 21.73 ± 1.54 [19--25] |
| 2026 | AR-RRG proposed | B-4 | 0.152 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | B-1 | 0.425 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | B-2 | 0.292 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | B-3 | 0.210 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | RG-L | 0.322 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | DiTPO proposed | F1 | 0.516 | data_setting=full-data | Rethinking the Efficiency and Effectiveness of Reinforcement Learning for Radiology Report GenerationSource quoteL233: Table \ref{table:mimic_results} details the comparative results on the MIMIC-CXR. Our DiTPO model with full-data establishes a new SOTA in clinical accuracy, achieving a F1 score of 0.516. This performance surpasses our basic GRPO framework (0.507) and previous leading RL methods like OISA (0.504), as well as strong SFT baselines such as SS-ACL (0.505), validating the effectiveness of directly optimizing for diagnostic entities. |
| 2026 | PCXR-Copilot pulmonary edema intensity index proposed | ROC AUC for grade 3 versus grade 0 pulmonary edema | 0.681 | no-retraining-or-fine-tuning | PCXR-Copilot: Device-aware pediatric chest radiographic analysis with segmentation, suppression, and edema-related cuesSource quoteL428: graphs) and grade 3 (alveolar edema; 82 radiographs), the AUC was 0.681 (95% CI |
| 2026 | RIHA (Report-Image Hierarchical Alignment Transformer) proposed | BLEU-1 | 0.385 | Reported benchmark result for RIHA on MIMIC-CXR; the split is not specified in the cite… | RIHA: Report-Image Hierarchical Alignment for Radiology Report GenerationSource quoteL146: On the more challenging MIMIC-CXR dataset, RIHA demonstrates competitive results, achieving the best scores in BLEU-1 (0.385), BLEU-2 (0.251), METEOR (0.159), and ROUGE-L (0.293). Our method shows consistent improvements over recent approaches including M2KT~\cite{yang2023radiology} (4.6% improvement on BLEU-1), CAMANET~\cite{wang2024camanet} (4.9% improvement on BLEU-1), and COMG~\cite{gu2024complex} (11.6% improvement on BLEU-1). |
| 2026 | RIHA (Report-Image Hierarchical Alignment Transformer) proposed | ROUGE-L | 0.293 | Reported benchmark result for RIHA on MIMIC-CXR; the split is not specified in the cite… | RIHA: Report-Image Hierarchical Alignment for Radiology Report GenerationSource quoteL146: On the more challenging MIMIC-CXR dataset, RIHA demonstrates competitive results, achieving the best scores in BLEU-1 (0.385), BLEU-2 (0.251), METEOR (0.159), and ROUGE-L (0.293). Our method shows consistent improvements over recent approaches including M2KT~\cite{yang2023radiology} (4.6% improvement on BLEU-1), CAMANET~\cite{wang2024camanet} (4.9% improvement on BLEU-1), and COMG~\cite{gu2024complex} (11.6% improvement on BLEU-1). |
| 2026 | LLaVA-TA proposed | RadGraph F1 | 31.1 | fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · evaluation_setting=in-distribution | Rethinking Radiology Report Generation: From Narrative Flow to Topic-Guided FindingsSource quoteL601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs. |
| 2026 | MEDA (QMS+PDI) proposed | Accuracy | 79.4% | multi-round · backbone=LLaVA-Med-1.5 · question_set=MedHEval · method_variant=QMS+PDI | MEDA: Medical-Oriented Activation Editing for Hallucination Mitigation in Medical Large Vision-Language ModelSource quoteL398: 79.4 |
| 2026 | ESC-RL proposed | F1 | 0.608 | Clinical efficacy (CE) comparison across 14 diseases; split not specified in the cited … | Enhancing Reinforcement Learning for Radiology Report Generation with Evidence-aware Rewards and Self-correcting Preference LearningSource quoteL317: ESC-RL (Ours) │ 0.632 │ 0.625 │ 0.608 │ 0.299 │ 0.311 │ 0.295 |
| 2026 | CheXOne-drafted reports proposed | cases with reports judged comparable to or better than resident-written reports | 55\% | split: test · study=radiologist reader study · sample-size=80 radiographs · radiologists=11 | A Reasoning-Enabled Vision-Language Foundation Model for Chest X-ray InterpretationSource quoteL18: A clinical reader study demonstrates that CheXOne-drafted reports are comparable to or better than resident-written reports in 55% of cases, while effectively addressing clinical indications and enhancing both report writing and CXR interpretation efficiency. |
| 2026 | MedCTA proposed | P@1 precision | 80.24% | subset=5×200 | Clinical Trajectory Alignment for Medical Vision-Language Pre-trainingSource quoteL398: Ours │ 80.24 │ 79.08 │ 75.68 │ 65.82 │ 69.13 │ 68.63 │ 67.23 │ 63.01 |
| 2026 | RadFusion (GPT-5 rewriter, default instruction) proposed | AUC-ROC (macro average) | .90 | rewriter=GPT-5 · instruction=default | RadFusion: Towards Threshold-Controllable Radiology Report GenerationSource quoteL194: GPT-5 │ default │ .93 │ .92 │ .92 │ .84 │ .92 │ .91 │ .88 │ .90 │ .88 │ .90 │ .90 │ .89 │ .93 │ .90 |
| 2026 | 7B baseline (ablation configuration 1; no alignment components enabled) ablation | B@4 | 0.134 | params=7B · backbone=7B · alignment-components=none | Graph-Supervised Hierarchical Clinical Alignment for Radiology Report Generation with Large Language ModelsSource quoteL463: 1 │ 7B │ 0.411 │ 0.134 │ 0.160 │ 0.297 │ 1.207 |
| 2026 | GRPO ablation | F1 | 0.507 | Directly compared with full-data DiTPO in the main results. | Rethinking the Efficiency and Effectiveness of Reinforcement Learning for Radiology Report GenerationSource quoteL233: Table \ref{table:mimic_results} details the comparative results on the MIMIC-CXR. Our DiTPO model with full-data establishes a new SOTA in clinical accuracy, achieving a F1 score of 0.516. This performance surpasses our basic GRPO framework (0.507) and previous leading RL methods like OISA (0.504), as well as strong SFT baselines such as SS-ACL (0.505), validating the effectiveness of directly optimizing for diagnostic entities. |
| 2026 | LLaVA-T ablation | RadGraph F1 | 1.6 | fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · anatomical_masks=excluded · evaluation_setting=in-distribution | Rethinking Radiology Report Generation: From Narrative Flow to Topic-Guided FindingsSource quoteL601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs. |
| 2026 | CoGaze (full model) | 14-observation micro-F1 (14Mi-F1) | 0.525 | Free-text report generation; metric covers the full set of 14 CheXbert-labeled observat… | Seeing Like Radiologists: Context- and Gaze-Guided Vision-Language Pretraining for Chest X-raysSource quoteL286: Effect of Multi-Level Supervision Paradigm. As shown in Tab.~ \ref{tab:ab-all}, starting from the hybrid-positive contrastive loss {\mathcal{L}-con}, incorporating gaze supervision ({\mathcal{L}-con}+{\mathcal{L}-G}) consistently improves performance across all metrics, with gains of + 0.6% BLEU2, +1.5% (14)Mi-F1, and +1.1% (5)Mi-F1. This suggests that soft gaze guidance provides complementary fine-grained alignment beyond contrastive learning. Further introducing the classification loss {\mathcal{L}-cls}, the full model (CoGaze) achieves the best overall performance, reaching 0.290 BLEU2, 0.596 BERTScore, and 0.525/0.571 on (14)Mi-F1 and (5)Mi-F1, respectively. These results validate the effectiveness of the proposed multi-level supervision paradigm. |
| 2026 | LLaVA-Rad | Age-group RadGraph-F1 fairness gap | 19.97 | Age-group gap; evaluation aggregates over subgroups of the other demographic attributes… | FairLLaVA: Fairness-Aware Parameter-Efficient Fine-Tuning for Large Vision-Language AssistantsSource quoteL632: 3.61 │ 3.39 │ 19.97 │ 16.91 |
| 2026 | LLaVA-Rad | Overall GREEN | 35.82 | Overall performance score; higher is better. | FairLLaVA: Fairness-Aware Parameter-Efficient Fine-Tuning for Large Vision-Language AssistantsSource quoteL634: 38.17 │ 15.40 │ 29.80 │ 35.82 |
| 2026 | BoxMed-RL | BLEU-3 | 0.185 | Downstream chest X-ray report generation; report target is the findings section; MIMIC-… | Reason like a radiologist: Chain-of-thought and reinforcement learning for verifiable report generationSource quoteL798: BoxMed-RL demonstrates significant performance in NLG metrics, achieving state-of-the-art performance in BLEU-3 and BLEU-4 scores across two datasets: MIMIC-CXR (0.185 and 0.134, Table 1) and IU Xray (0.240 and 0.178, Table 2). It also yields an average improvement of 7 % in both METEOR and ROUGE-L, metrics that emphasize semantic adequacy and content coverage. These consistent gains on external datasets not included in pretraining underscore the robustness and generalizability of our framework. |
| 2026 | BoxMed-RL | BLEU-4 | 0.134 | Downstream chest X-ray report generation; report target is the findings section; MIMIC-… | Reason like a radiologist: Chain-of-thought and reinforcement learning for verifiable report generationSource quoteL798: BoxMed-RL demonstrates significant performance in NLG metrics, achieving state-of-the-art performance in BLEU-3 and BLEU-4 scores across two datasets: MIMIC-CXR (0.185 and 0.134, Table 1) and IU Xray (0.240 and 0.178, Table 2). It also yields an average improvement of 7 % in both METEOR and ROUGE-L, metrics that emphasize semantic adequacy and content coverage. These consistent gains on external datasets not included in pretraining underscore the robustness and generalizability of our framework. |
| 2026 | BoxMed-RL | CheXbert F1 | 0.466 | Downstream report-generation evaluation on MIMIC-CXR; report target is the findings sec… | Reason like a radiologist: Chain-of-thought and reinforcement learning for verifiable report generationSource quoteL807: BoxMed-RL demonstrates stable performance in analyzing clinical concepts, achieving a CheXbert F1 score of 0.466 on MIMIC-CXR and a cosine similarity of 0.610 on IU X-ray. This consistency contrasts with PromptMRG, which shows unstable performance, ranking second in MIMIC-CXR but dropping to fourth in IU X-ray. |
| 2026 | CLIP | Mean Resultant Length (R) | 0.915 | backbone=CLIP | On the Cone Effect and Modality Gap in Medical Vision-Language EmbeddingsSource quoteL159: MIMIC-CXR │ 0.915 │ 0.862 │ 0.899 │ 0.726 │ 0.970 │ 0.974 │ 0.910 │ 0.735 |
| 2026 | CLIP | Mean Resultant Length (R) | 0.970 | backbone=CLIP | On the Cone Effect and Modality Gap in Medical Vision-Language EmbeddingsSource quoteL159: MIMIC-CXR │ 0.915 │ 0.862 │ 0.899 │ 0.726 │ 0.970 │ 0.974 │ 0.910 │ 0.735 |
| 2026 | REVTAF | F1 | 0.592 | Clinical efficacy (CE) comparison across 14 diseases; split not specified in the cited … | Enhancing Reinforcement Learning for Radiology Report Generation with Evidence-aware Rewards and Self-correcting Preference LearningSource quoteL312: REVTAF │ \textcolor{blue}{0.628} │ \textcolor{blue}{0.613} │ \textcolor{blue}{0.592} │ \textcolor{blue}{0.286} │ \textcolor{blue}{0.282} │ \textcolor{blue}{0.273} |
| 2026 | REVTAF baseline | F1 | 0.589 | split: test | The Double Dilemma in Multi-Task Radiology Report Generation: A Gradient Dynamics Analysis and SolutionSource quoteL516: REVTAF │ ICCV'25 │ 0.615 │ 0.617 │ 0.589 │ 0.465 │ 0.319 │ 0.236 │ 0.184 │ 0.199 │ 0.336 │ 0.607 |
| 2026 | RN50(KAN) + Grad-CAM (G) baseline | IoU | 0.060 | backbone=ResNet-50 with KAN head · backbone_status=pretrained and frozen · explanation_method=Grad-CAM | KANEx: Translating Kolmogorov-Arnold Networks' Interpretability to Medical ExplainabilitySource quoteL144: 0.060 │ -- │ 0.069 |
| 2026 | RN50(KAN) + Grad-CAM (G) baseline | Faithfulness | 3.893 | backbone=ResNet-50 with KAN head · backbone_status=pretrained and frozen · explanation_method=Grad-CAM | KANEx: Translating Kolmogorov-Arnold Networks' Interpretability to Medical ExplainabilitySource quoteL147: 3.893 │ -- │ 9.116 |
| 2026 | Verbalize Base (sentence-level) baseline | ECE | 0.438 | granularity=sentence-level | Calibrated Confidence Expression for Radiology Report GenerationSource quoteL101: Verbalize Base │ 0.438 {[0.423, 0.453]} │ 0.558 {[0.543, 0.572]} │ 0.268 {[0.257, 0.279]} |
| 2026 | Verbalize Base (sentence-level) baseline | AUROC | 0.558 | granularity=sentence-level | Calibrated Confidence Expression for Radiology Report GenerationSource quoteL101: Verbalize Base │ 0.438 {[0.423, 0.453]} │ 0.558 {[0.543, 0.572]} │ 0.268 {[0.257, 0.279]} |
| 2026 | Verbalize Base (sentence-level) baseline | GREEN | 0.268 | granularity=sentence-level | Calibrated Confidence Expression for Radiology Report GenerationSource quoteL101: Verbalize Base │ 0.438 {[0.423, 0.453]} │ 0.558 {[0.543, 0.572]} │ 0.268 {[0.257, 0.279]} |
| 2026 | Prior-diagnosis rule baseline | F2 (macro) | 0.385 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL895: reaches 0.385 macro F2 under P4 and 0.337 under P4-C, above |
| 2026 | Prior-diagnosis rule baseline | F2 (macro) | 0.337 | split: patient-grouped | Leakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR ClassificationSource quoteL895: reaches 0.385 macro F2 under P4 and 0.337 under P4-C, above |
| 2026 | Claude 4.5 (H) baseline | CD-↑ (upward certainty distortion rate) | 20% | iteration=1 | From ‘May’ to ‘Is’: Certainty Distortion in Language Model RewritingSource quoteL273: On the other hand, in the medical domain, CD-\uparrow continues to climb through turn 5: \texttt{Claude 4.5 (H)}\xspace, for instance, goes from 20% CD-\uparrow\xspace after one iteration to 40% after five. |
| 2026 | Claude 4.5 (H) baseline | CD-↑ (upward certainty distortion rate) | 40% | iteration=5 | From ‘May’ to ‘Is’: Certainty Distortion in Language Model RewritingSource quoteL273: On the other hand, in the medical domain, CD-\uparrow continues to climb through turn 5: \texttt{Claude 4.5 (H)}\xspace, for instance, goes from 20% CD-\uparrow\xspace after one iteration to 40% after five. |
| 2026 | GPT-5 baseline non-standard slice | accuracy | 0.83 | labels=binary normal/abnormal · prompt=neutral v0 · subset=balanced · modality-shift=no-shift | Medical Context Distorts Decisions in Clinical Vision Language ModelsSource quoteL22: This pattern was consistent across model families. Under the multimodal setting ("No Shift"), accuracies ranged from 0.66 (Janus-Pro) to 0.83 (GPT-5, Gemini 3 Pro), with frontier closed models achieving the strongest overall performance by a small margin. However, once conflicting text ("Text Shift") was introduced, accuracy collapsed, dropping to 0.17-0.34, below random chance for all evaluated models. The strongest frontier system dropped the accuracy from 0.83 to 0.18 for GPT-5, and from 0.83 to 0.17 for Gemini 3 Pro. Likewise, strong open models such as Qwen-2 VL and LLaVA 1.5 fell from 0.81 to 0.20 and 0.78 to 0.20, respectively, showing a strong text preference. |
| 2026 | GPT-5 baseline non-standard slice | accuracy | 0.18 | labels=binary normal/abnormal · prompt=neutral v0 · subset=balanced · modality-shift=text-shift | Medical Context Distorts Decisions in Clinical Vision Language ModelsSource quoteL22: This pattern was consistent across model families. Under the multimodal setting ("No Shift"), accuracies ranged from 0.66 (Janus-Pro) to 0.83 (GPT-5, Gemini 3 Pro), with frontier closed models achieving the strongest overall performance by a small margin. However, once conflicting text ("Text Shift") was introduced, accuracy collapsed, dropping to 0.17-0.34, below random chance for all evaluated models. The strongest frontier system dropped the accuracy from 0.83 to 0.18 for GPT-5, and from 0.83 to 0.17 for Gemini 3 Pro. Likewise, strong open models such as Qwen-2 VL and LLaVA 1.5 fell from 0.81 to 0.20 and 0.78 to 0.20, respectively, showing a strong text preference. |
| 2026 | GPT-5 baseline non-standard slice | accuracy | 0.82 | labels=binary normal/abnormal · prompt=neutral v0 · subset=balanced · modality-shift=image-shift | Medical Context Distorts Decisions in Clinical Vision Language ModelsSource quoteL24: By contrast, replacing the image while keeping the original text ("Image Shift") produced only minor changes in accuracy for most models. Qwen-2 VL remained essentially unchanged (0.81 to 0.80), LLaVA 1.5 remained at 0.78, GPT-5 changed only from 0.83 to 0.82, and Gemini 3 Pro from 0.83 to 0.82. Even the medically-adapted models, were far more robust to image perturbation than to text perturbation (MedGemma: 0.76 to 0.72 vs. 0.76 to 0.28; MedGemma 1.5: 0.79 to 0.74 vs. 0.79 to 0.26). This gap between Text Shift and Image Shift strongly suggests that unlike real radiology scenarios the image often plays a secondary role in the final decision for VLMs. |
| 2026 | UBAIA baseline | Acc/Avg | 0.789 | Individual Subgroup: Race; average accuracy as reported in the overall accuracy and fai… | Stride-Net: Fairness-Aware Disentangled Representation Learning for Chest X-Ray DiagnosisSource quoteL207: 0.789 │ {0.935} │ 0.830 |
| 2026 | UBAIA baseline | EOM | 0.830 | Individual Subgroup: Race; fairness result in the overall comparison table, not the rac… | Stride-Net: Fairness-Aware Disentangled Representation Learning for Chest X-Ray DiagnosisSource quoteL207: 0.789 │ {0.935} │ 0.830 |
| 2026 | KARGEN baseline | RadGraph F1 | 0.203 | resolution=224×224 | Graph-Supervised Hierarchical Clinical Alignment for Radiology Report Generation with Large Language ModelsSource quoteL401: 0.203 │ 0.421 │ 1.165 |
| 2026 | LM-RRG baseline | CheXbert | 0.484 | Baseline in the MIMIC-CXR report-generation comparison; CheXbert clinical-efficacy score. | Reason like a radiologist: Chain-of-thought and reinforcement learning for verifiable report generationSource quoteL808: As shown in Table 1, the top four CheXbert scores: LM-RRG (0.484), |
| 2026 | Lumina baseline | FID | 15.77 | split: test · subset=1,000 report-image pairs | Discrete Diffusion Bridges for Spatiotemporally Aligned Image Translation and GenerationSource quoteL516: Lumina. \cite{xin2025lumina} │ 21.40 │ 0.716 │ 0.127 │ 24.47 │ 0.728 │ 0.078 │ 15.77 │ 0.403 │ 0.437 │ 25.21 │ 0.781 │ 0.085 |
| 2026 | OMIB (Wu et al., 2025) baseline | mAUC | 71.0% | split: test · subset=five diseases | IBMA: Information Bottleneck-Based Multimodal AlignmentSource quoteL478: 71.0 |
| 2026 | LLaVA-Rad baseline | F1-CheXbert (F1₁₄) | 0.320 | condition=full-noise-image · corruption-level=image-level | SHOVIR: A Benchmark for Evaluating Vision Shortcut Learning in Radiology Report GenerationSource quoteL363: Conversely, LLaVA-Rad is the least sensitive to noise, retaining the highest F1\textsubscript{14} under full corruption (0.320 on MIMIC-CXR; 0.175 on PadChest-GR) and yielding the smallest \Delta_{\text{FN}} on both datasets (0.252 and 0.266, respectively), while retaining a moderate GREEN score under Full Noise Image. |
| 2026 | LLaVA-Med-1.5 (Baseline) baseline | Accuracy | 72.5% | multi-round · backbone=LLaVA-Med-1.5 · question_set=MedHEval | MEDA: Medical-Oriented Activation Editing for Hallucination Mitigation in Medical Large Vision-Language ModelSource quoteL261: 72.5 |
| 2025 | GPT-4o, Thought Graph Traversal (TGT) proposed | BLEU-4 | 9.84% | split: test · backbone=GPT-4o | Simple Radiology VLLM Test-time Scaling with Thought Graph TraversalSource quoteL200: TGT │ 29.25 │ 15.81 │ 8.95 │ 9.84 │ 14.12 │ 26.50 |
| 2025 | HuatuoGPT-Vision, Thought Graph Traversal (TGT) proposed | BLEU-4 | 11.34% | split: test · backbone=HuatuoGPT-Vision | Simple Radiology VLLM Test-time Scaling with Thought Graph TraversalSource quoteL208: TGT │ 32.99 │ 18.89 │ 10.85 │ 11.34 │ 14.36 │ 27.06 |
| 2025 | HiMed-3B proposed | RATE (RaTEScore) | 0.544 | params=3B | Beyond N-grams: A Hierarchical Reward Learning Framework for Clinically-Aware Medical Report GenerationSource quoteL272: HiMed-3B (\S) │ 0.292 │ 0.156 │ 0.088 │ 0.052 │ 0.289 │ 0.079 │ 0.271 │ 0.220 │ 0.544 |
| 2025 | MoColl + tuned VQA model proposed | ROUGE-L | 0.2349 | fine-tuned | MoColl: Agent-Based Specific and General Model Collaboration for Image CaptioningSource quoteL218: MoColl + tuned VQA model (Ours) │ \bf{0.2749} │ \bf{0.1454} │ \bf{0.0897} │ \bf{0.0655} │ \bf{0.1126} │ \bf{0.2349} │ \bf{0.0932} |
| 2025 | MoColl + aligned VLM proposed | ROUGE-L | 0.1906 | fine-tuned | MoColl: Agent-Based Specific and General Model Collaboration for Image CaptioningSource quoteL217: MoColl + aligned VLM (Ours) │ 0.2515 │ 0.1290 │ 0.0746 │ 0.0456 │ 0.0947 │ 0.1906 │ 0.0566 |
| 2025 | DLDM (disentangled latent diffusion model) proposed | Effectiveness Accuracy | 89.2% | split: test · intervention=do(A=black) | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL605: DLDM │ 89.2 │ 92.0 │ 93.7 |
| 2025 | Hulu-Med-7B proposed | RaTEScore | 57.0 | model=Hulu-Med-7B · params=7B | Hulu-Med: A Transparent Generalist Model towards Holistic Medical Vision-Language UnderstandingSource quoteL31: We evaluated Hulu-Med on three standard 2D MRG benchmarks, including MIMIC-CXR, CheXpert, and IU X-ray, and assessed performance using both standard metrics (BLEU, ROUGE, METEOR) and the clinically-oriented metric RaTEScore~\cite{demner2015preparing,zhao2024ratescore,irvin2019chexpert,johnson2019mimic} (\textcolor{blue}{Fig.~\ref{fig:2d_results}a-b}). All Hulu-Med variants achieved state-of-the-art performance across these benchmarks. Notably, on MIMIC-CXR, Hulu-Med-7B attained a RaTEScore of 57.0, substantially exceeding the previous best model, MedGemma-4B/27B (RaTEScore 51.3) (\textcolor{blue}{Fig.~\ref{fig:2d_results}b}). This result is clinically significant, as MedGemma's score corresponded to 81% of its reports leading to the same or superior clinical decisions compared to original reports, as judged by a board-certified radiologist~\cite{sellergren2025medgemma}. Our results further demonstrate that larger model size does not guarantee superior MRG performance, as evidenced by Hulu-Med-7B occasionally surpassing its 32B counterpart, a pattern also observed with MedGemma. This finding underscores that domain-specific pretraining is critical for specialized tasks like MRG, affirming the necessity of developing medical vision-language models. |
| 2025 | Synthetic+Real mix model (maximal synthetic data) proposed | AUROC | 0.770 | split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL135: The synthetic+real model with maximal data achieved an AUROC of 0.770 (CI: 0.762-0.778) for the multi-label classification task on the in-distribution MIMIC-CXR test set. |
| 2025 | IDEFICS+ADA-Steal proposed | RG-L | 21.4 | fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100 | Medical Multimodal Model Stealing Attacks via Adversarial Domain AlignmentSource quoteL285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3 |
| 2025 | IDEFICS+ADA-Steal proposed | Bert-S | 48.0 | fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100 | Medical Multimodal Model Stealing Attacks via Adversarial Domain AlignmentSource quoteL285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3 |
| 2025 | IDEFICS+ADA-Steal proposed | Rad-S | 14.1 | fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100 | Medical Multimodal Model Stealing Attacks via Adversarial Domain AlignmentSource quoteL285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3 |
| 2025 | MedUnifier (w TIG) proposed | BLEU-1 (BL-1) | 41.5 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MedUnifier (w TIG) proposed | BLEU-4 (BL-4) | 12.9 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MedUnifier (w TIG) proposed | METEOR (MTR) | 22.7 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MedUnifier (w TIG) proposed | ROUGE-L (RG-L) | 34.0 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MedUnifier proposed | FID (lower is better) | 46.2 | FID uses the MIMIC-CXR pre-training dataset as the reference. The table does not explic… | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL268: LLM-CXR\cite{lee2023llm} │ 22.8 │ MedUnifier │ 46.2 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.75 | split: test · fine-tuned · view=frontal · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL137: Frontal │ 0.75 │ 0.65 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.73 | split: test · fine-tuned · view=lateral · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL138: Lateral │ 0.73 │ 0.65 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.75 | split: test · fine-tuned · view=frontal+lateral ensemble · fusion=late · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL139: Ensemble │ 0.75 │ 0.69 \multirow{3}{*}{Contrastive} |
| 2025 | SS-ACL proposed | BLEU-4 | 0.144 | split: test · test-samples=3858 | Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report GenerationSource quoteL447: {\color[HTML]{C00000} 0.144} |
| 2025 | SS-ACL proposed | Clinical efficacy macro F1 | 0.505 | split: test · categories=14 thoracic diseases · test-samples=3858 · clinical-labeler=CheXbert | Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report GenerationSource quoteL453: {\color[HTML]{C00000} 0.505} |
| 2025 | MedAlign proposed | RadGraph F1 | 10.92 | peft · backbone=LLaVA-Med-1.5 · fine-tuning=without LoRA | Enhancing Medical Large Vision-Language Models via Alignment DistillationSource quoteL441: MedAlign\xspace │ 4.51 │ 18.43 │ 20.80 │ 86.00 │ 25.67 │ 10.92 │ 42.03 |
| 2025 | DDaTR (SwinT-B) proposed | F1_macro (Clinical Efficacy) | 0.441 | split: test · backbone=SwinT-B · averaging=macro | DDaTR: Dynamic Difference-aware Temporal Residual Network for Longitudinal Radiology Report GenerationSource quoteL313: Ours │ 0.438 │ 0.465 │ 0.441 (+0.049) │ 0.113 │ 0.162 │ 0.272 |
| 2025 | AM-MRG proposed | BLEU-4 | 0.136 | NLG report-generation metric on MIMIC-CXR; split and averaging are not specified in the… | Activating Associative Disease-Aware Vision Token Memory for LLM-Based X-Ray Report GenerationSource quoteL344: In the MIMIC-CXR dataset, AM-MRG secures the best results for all metrics except CIDEr, with scores of 0.426 for BLEU-1, 0.271 for BLEU-2, 0.187 for BLEU-3, 0.136 for BLEU-4, 0.291 for ROUGE-L, and 0.174 for METEOR. Additionally, BLEU-4 has improved by 8.8% relative to R2GenGPT~\cite{Wang2023R2GenGPT}. |
| 2025 | AM-MRG proposed | F1 | 0.484 | Clinical Efficacy (CE) metric on MIMIC-CXR; split and averaging are not specified in th… | Activating Associative Disease-Aware Vision Token Memory for LLM-Based X-Ray Report GenerationSource quoteL349: As depicted in Tables \ref{tab:CE_Metrics_Mimic_CXR_results} and \ref{tab:CE_Metrics_CheXpert_Plus_results}, we have evaluated the accuracy of our model, AM-MRG, in delineating clinical abnormalities by reporting the Clinical Efficacy (CE) metrics alongside seven other models across two distinct datasets. On the MIMIC-CXR dataset, AM-MRG yielded impressive results with Precision, Recall, and F1 scores of 0.555, 0.429, and 0.484, respectively. Notably, the Recall and F1 scores surpass those of the competing models, with the F1 score a remarkable 19.5% higher than the second-best model, CoFE~\cite{li2025CoFE}. In the Chexpert Plus dataset, AM-MRG took the lead in all three metrics, achieving Precision, Recall, and F1 scores of 0.396, 0.318, and 0.336, respectively. The F1 score represented a significant 16.6% improvement over the runner-up, Token-Mixer~\cite{Yang2024Token-Mixer}, signifying a substantial edge. |
| 2025 | DiffRGenNet proposed | F1 | 0.483 | split: test | DiffRGenNet: Difference-aware Medical Report GenerationSource quoteL286: 0.483 |
| 2025 | MedAlign proposed | F1 | 95.25% | split: test · params=7B · backbone=LLaVA-Med-1.5 7B | MedAlign: A Synergistic Framework of Multimodal Preference Optimization and Federated Meta-Cognitive ReasoningSource quoteL417: MedAlign │ 95.64 │ 96.47 │ 95.25 │ 94.36 │ 22.99 │ 27.89 │ 16.33 │ 2.29 |
| 2025 | ARRA (text-generation-only LLM initialization) proposed | FID | 5.30 | split: test · subset=1,000 pairs · resolution=512×512 | Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation AlignmentSource quoteL309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576. |
| 2025 | ARRA (text-generation-only LLM initialization) proposed | CLIP-Score | 0.4532 | split: test · subset=1,000 pairs · backbone=CLIP · resolution=512×512 | Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation AlignmentSource quoteL309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576. |
| 2025 | ARRA-Adapt (general image-generation pretrained LLM initialization) proposed | FID | 4.15 | split: test · subset=1,000 pairs · resolution=512×512 | Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation AlignmentSource quoteL309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576. |
| 2025 | ARRA-Adapt (general image-generation pretrained LLM initialization) proposed | CLIP-Score | 0.4576 | split: test · subset=1,000 pairs · backbone=CLIP · resolution=512×512 | Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation AlignmentSource quoteL309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576. |
| 2025 | MeDiM proposed | FID | 16.60 | split: test | Discrete Diffusion Models with MLLMs for Unified Medical Multimodal GenerationSource quoteL34: 1) For medical image generation, MeDiM achieves state-of-the-art Frechet Inception Distances (FID) on the MIMIC-CXR~\citep{johnson2019mimic} and PathGen~\citep{sun2024pathgen} datasets, respectively (Tab.~\ref{tab_1} and Tab.~\ref{tab_2}; 16.60 FID and 24.19 FID), generating high-fidelity medical images across different modalities (Fig.~\ref{fig_qual}; robust and high visual quality). |
| 2025 | MeDiM proposed non-standard slice | METEOR (table label: MTR) | 0.265 | split: test | Discrete Diffusion Models with MLLMs for Unified Medical Multimodal GenerationSource quoteL275: MeDiM (Ours) │ MLLM │ 0.328 │ 0.185 │ 0.109 │ 0.265 │ 0.297 │ 0.185 │ 0.084 │ 0.037 │ 0.258 │ 0.226 |
| 2025 | CURV proposed | BLEU-3 (B-3) | 9.85 | params=3B | CURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report GenerationSource quoteL210: 9.85 |
| 2025 | CURV proposed | RadGraph F1 | 19.54 | params=3B | CURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report GenerationSource quoteL277: 19.54 |
| 2025 | MedOrch proposed | Macro AUC | 61.2% | Chest X-ray analysis; macro-level metric. | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteL4: Healthcare decision-making represents one of the most challenging domains for Artificial Intelligence (AI), requiring the integration of diverse knowledge sources, complex reasoning, and various external analytical tools. Current AI systems often rely on either task-specific models, which offer limited adaptability, or general language models without grounding with specialized external knowledge and tools. We introduce \texttt{MedOrch}\xspace, a novel framework that orchestrates multiple specialized tools and reasoning agents to provide comprehensive medical decision support. \texttt{MedOrch}\xspace employs a modular, agent-based architecture that facilitates the flexible integration of domain-specific tools without altering the core system. Furthermore, it ensures transparent and traceable reasoning processes, enabling clinicians to meticulously verify each intermediate step underlying the system’s recommendations. We evaluate \texttt{MedOrch}\xspace across three distinct medical applications: Alzheimer's disease diagnosis, chest X-ray interpretation, and medical visual question answering, using authentic clinical datasets. The results demonstrate \texttt{MedOrch}\xspace's competitive performance across these diverse medical tasks. Notably, in Alzheimer's disease diagnosis, \texttt{MedOrch}\xspace achieves an accuracy of 93.26%, surpassing the state-of-the-art baseline by over four percentage points. For predicting Alzheimer's disease progression, it attains a 50.35% accuracy, marking a significant improvement. In chest X-ray analysis, \texttt{MedOrch}\xspace exhibits superior performance with a Macro AUC of 61.2% and a Macro F1-score of 25.5%. Moreover, in complex multimodal visual question answering (Image+Table), \texttt{MedOrch}\xspace achieves an accuracy of 54.47%. These findings underscore \texttt{MedOrch}\xspace's potential to advance healthcare AI by enabling reasoning-driven tool utilization for multimodal medical data processing and supporting intricate cognitive tasks in clinical decision-making. |
| 2025 | MedOrch proposed | Macro F1-score | 25.5% | Chest X-ray analysis; macro-level metric. | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteL4: Healthcare decision-making represents one of the most challenging domains for Artificial Intelligence (AI), requiring the integration of diverse knowledge sources, complex reasoning, and various external analytical tools. Current AI systems often rely on either task-specific models, which offer limited adaptability, or general language models without grounding with specialized external knowledge and tools. We introduce \texttt{MedOrch}\xspace, a novel framework that orchestrates multiple specialized tools and reasoning agents to provide comprehensive medical decision support. \texttt{MedOrch}\xspace employs a modular, agent-based architecture that facilitates the flexible integration of domain-specific tools without altering the core system. Furthermore, it ensures transparent and traceable reasoning processes, enabling clinicians to meticulously verify each intermediate step underlying the system’s recommendations. We evaluate \texttt{MedOrch}\xspace across three distinct medical applications: Alzheimer's disease diagnosis, chest X-ray interpretation, and medical visual question answering, using authentic clinical datasets. The results demonstrate \texttt{MedOrch}\xspace's competitive performance across these diverse medical tasks. Notably, in Alzheimer's disease diagnosis, \texttt{MedOrch}\xspace achieves an accuracy of 93.26%, surpassing the state-of-the-art baseline by over four percentage points. For predicting Alzheimer's disease progression, it attains a 50.35% accuracy, marking a significant improvement. In chest X-ray analysis, \texttt{MedOrch}\xspace exhibits superior performance with a Macro AUC of 61.2% and a Macro F1-score of 25.5%. Moreover, in complex multimodal visual question answering (Image+Table), \texttt{MedOrch}\xspace achieves an accuracy of 54.47%. These findings underscore \texttt{MedOrch}\xspace's potential to advance healthcare AI by enabling reasoning-driven tool utilization for multimodal medical data processing and supporting intricate cognitive tasks in clinical decision-making. |
| 2025 | LANCE proposed | CPG | 0.81 | resolution=512×512 · intervention=do(sex) | Leveraging Vision-Language Foundation Models to Reveal Hidden Image-Attribute Relationships in Medical ImagingSource quoteL97: Ours │ 0.81 │ 0.89 │ 0.75 |
| 2025 | LANCE proposed | CPG | 0.89 | resolution=512×512 · intervention=do(disease) | Leveraging Vision-Language Foundation Models to Reveal Hidden Image-Attribute Relationships in Medical ImagingSource quoteL97: Ours │ 0.81 │ 0.89 │ 0.75 |
| 2025 | LANCE proposed | CPG | 0.75 | resolution=512×512 · intervention=do(race) | Leveraging Vision-Language Foundation Models to Reveal Hidden Image-Attribute Relationships in Medical ImagingSource quoteL97: Ours │ 0.81 │ 0.89 │ 0.75 |
| 2025 | CXR-LanSE proposed non-standard slice | number of distinct radiological patterns | 899 patterns | Patterns discovered using the interpretability framework adapted for medical data. | Interpretable Evaluation of AI-Generated Content with Language-Grounded Sparse EncodersSource quoteL36: CXR-LanSE extends our content analysis approach to medical imaging by systematically discovering clinical visual patterns in chest X-ray images. Using the same interpretability framework adapted for medical data, CXR-LanSE identifies 899 distinct radiological patterns from MIMIC-CXR datasets and AI-generated medical images. These patterns capture clinically meaningful features ranging from anatomical landmarks to pathological findings and medical devices. To validate the clinical relevance of discovered patterns, we conducted evaluations with two expert radiologists who assessed pattern-image correspondence on randomly selected neuron-image pairs. Each pair consisted of a CXR-LanSE pattern description and a chest X-ray image that activated the corresponding neuron. The radiologists judged whether the automated interpretation accurately captured clinically meaningful features present in the image. |
| 2025 | MCA-RG (7B; listed as Ours) proposed | ROUGE-L (RG-L) | 0.300 | params=7B | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL138: Ours │ 7B │ 0.411 │ 0.256 │ 0.175 │ 0.128 │ 0.163 │ 0.300 |
| 2025 | MCA-RG (7B; listed as Ours) proposed | Example-based F1 | 0.408 | split: test · params=7B · scores=CE · averaging=example-based | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt] |
| 2025 | MCA-RG (7B; listed as Ours) proposed | Macro-based F1 | 0.335 | split: test · params=7B · scores=CE · averaging=macro-based | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt] |
| 2025 | ChexGen proposed | FID (CLIP features) | 0.89 | split: test · backbone=CLIP · sample-size=3500 cases · feature-extractor=CLIP | A Generative Foundation Model for Chest RadiographySource quoteL76: We assessed fidelity by calculating the FID (lower is better) between synthetic and real CXRs, extracting features from a pretrained general-purpose model (CLIP~\cite{radford2021learning}) and a domain-specific chest radiograph classifier (XRV~\cite{Cohen2022xrv}). ChexGen achieved substantially better fidelity with lower FID scores compared to MINIM-CXR~\cite{wang2024self} and RoentGen~\cite{chambon2022roentgen} (CLIP: 0.89 vs. 9.63 and 4.42; XRV: 0.57 vs. 8.29 and 6.80) (\textbf{\cref{fig:figure2}a}, p < 0.001). These results demonstrate that ChexGen better captures the distribution of real-world chest radiographs. |
| 2025 | ChexGen-balanced DenseNet121 model proposed | Weighted F1-score for worst-performing gender group | 0.387 | split: test · model=DenseNet121 · subgroup=worst-performing gender group · training-data=ChexGen-balanced | A Generative Foundation Model for Chest RadiographySource quoteL160: In addition to detecting model bias, we explored whether synthetic data could be used to further mitigate the observed bias. Using ChexGen, we generated additional training samples for underrepresented demographic subgroups until their representation matched that of the majority groups. Consequently, the augmented training data led to substantial improvements in model fairness across all demographic dimensions. For instance, the F1-Scores increased significantly for the worst group (gender: 0.338 to 0.387, race: 0.321 to 0.394, age: 0.363 to 0.419), while performance gaps between best and worst groups narrowed considerably with a relative reduction of up to 60% (gender: 2.5% to 1.6%, race: 2.9% to 1.2%, age: 2.3% to 1.2%) (\textbf{\cref{fig:figure6}d}). These results highlight the potential of CheXGen for generating synthetic data to enhance model fairness by detecting and mitigating bias. |
| 2025 | MAIRA-2 + CCD proposed | RadGraph-F1 | 19.01 | Radiology report generation; CCD applied to MAIRA-2. | CCD: Mitigating Hallucinations in Radiology MLLMs via Clinical Contrastive DecodingSource quoteL478: \(+\) CCD │ 20.70 │ 2.10 │ 51.62 │ 19.01 │ 17.58 │ 53.32 │ 17.50 │ 27.05 │ 16.02 |
| 2025 | Domain-specific tokenizer (Specific) proposed | R-L | 0.344 | split: test · vocabulary-size=9.1k | Specialised or Generic? Tokenization Choices for Radiology Language ModelsSource quoteL167: Specific │ \ding{55} │ 9.1k │ 0.273 │ 0.364 │ 0.344 │ 0.514 │ 0.604 │ 0.270 │ 0.813 |
| 2025 | DCFG (ω_aff=2.5, ω_inv=1.2) proposed | ROC-AUC (intervened Sex) | 99.9 | omega-aff=2.5 · omega-inv=1.2 · intervention=do(sex) · target-label=pleural-effusion | Factored Classifier-Free GuidanceSource quoteL658: \omega-aff=2.5, \omega-inv=1.2 │ \inter{99.9 / +7.5} │ \uninter{74.9 / -0.7} │ \uninter{90.1 / +1.3} │ 0.199 │ 0.260 |
| 2025 | DCFG (ω_aff=2.5, ω_inv=1.2) proposed | ROC-AUC (invariant Race) | 74.9 | attribute=Race (invariant) · omega-aff=2.5 · omega-inv=1.2 · intervention=do(sex) | Factored Classifier-Free GuidanceSource quoteL658: \omega-aff=2.5, \omega-inv=1.2 │ \inter{99.9 / +7.5} │ \uninter{74.9 / -0.7} │ \uninter{90.1 / +1.3} │ 0.199 │ 0.260 |
| 2025 | OTDRG proposed | BLEU-1 | 0.411 | Report-generation comparison table; table states results are from the original papers. | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | OTDRG proposed | BLEU-4 | 0.128 | Report-generation comparison table; table states results are from the original papers. | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | OTDRG proposed | METEOR | 0.164 | Report-generation comparison table; table states results are from the original papers. | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | OTDRG proposed | ROUGE-L | 0.295 | Report-generation comparison table; table states results are from the original papers. | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | OTDRG proposed | Clinical efficacy F1 | 0.436 | disease-labels=14 · clinical-labeler=CheXbert | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | RadVLM+RL (GRPO) proposed | BERTScore (B-S) | 59.2 | split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findings | RadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement LearningSource quoteL117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86 |
| 2025 | RadVLM+RL (GRPO) proposed | GREEN (GRN) | 32.7 | split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findings | RadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement LearningSource quoteL117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86 |
| 2025 | RadVLM+RL (GRPO) proposed | RadCliQ (RCQ) | 0.86 | split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findings | RadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement LearningSource quoteL117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86 |
| 2025 | CoCa-CXR, description-only generation proposed | RadGraph F1 | 24.2% | Generates descriptions only; CoCa-CXR and the compared models rely solely on images as … | CoCa-CXR: Contrastive Captioners Learn Strong Temporal Structures for Chest X-Ray Vision-Language UnderstandingSource quoteL127: Tab.~\ref{tab:mimic-cxr} presents report generation results on the MIMIC-CXR dataset \cite{johnson2019mimic}. CoCa-CXR predicts both FINDINGS and IMPRESSION sections, a more challenging task than FINDINGS alone \cite{bannur2023learning}. When generating only descriptions, it achieves a RadGraph F1 score of 24.2%, on par with large-scale models like Med-Gemini \cite{yang2024advancing}. Notably, PaliGemma-2 \cite{steiner2024paligemma} incorporates both images and the indication section as inputs, whereas CoCa-CXR and other models in Tab.~\ref{tab:mimic-cxr} rely solely on images; hence, we exclude its result for fair comparison. |
| 2025 | CoCa-CXR, generating comparison descriptions proposed | RadGraph F1 | 23.7% | Generates comparison descriptions in addition to descriptions. | CoCa-CXR: Contrastive Captioners Learn Strong Temporal Structures for Chest X-Ray Vision-Language UnderstandingSource quoteL128: When also generating comparison descriptions, CoCa-CXR attains a RadGraph F1 score of 23.7%. Although this is slightly lower than description-only generation, our hypothesis is that, describing progression adds another dimension to report generation tasks, and with the current accuracy-level (65%) on temporal classification, one can obtain a similar level of benefit on Radgraph F1 by simply omitting comparisons in the generated reports. But still, as shown in Fig. \ref{fig:pos_vs_neg_order}, this is step forward in incorporating this progression dimension and towards real world application. |
| 2025 | RRG-opt proposed | BLEU2 | 0.157 | subset=3.70% | CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest RadiographsSource quoteL168: RRG-opt (ours) │ 3.70% │ 0.241 │ 0.157 │ 0.108 │ 0.078 │ 0.109 │ 0.239 │ 0.513 |
| 2025 | RRG-opt proposed | BLEU3 | 0.108 | subset=3.70% | CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest RadiographsSource quoteL168: RRG-opt (ours) │ 3.70% │ 0.241 │ 0.157 │ 0.108 │ 0.078 │ 0.109 │ 0.239 │ 0.513 |
| 2025 | RRG-opt proposed | BLEU4 | 0.078 | subset=3.70% | CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest RadiographsSource quoteL168: RRG-opt (ours) │ 3.70% │ 0.241 │ 0.157 │ 0.108 │ 0.078 │ 0.109 │ 0.239 │ 0.513 |
| 2025 | RRG-opt proposed | ROUGEL | 0.239 | subset=3.70% | CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest RadiographsSource quoteL168: RRG-opt (ours) │ 3.70% │ 0.241 │ 0.157 │ 0.108 │ 0.078 │ 0.109 │ 0.239 │ 0.513 |
| 2025 | R-CLIP-opt proposed | AUC | 0.848 | subset=1% · backbone=CLIP | CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest RadiographsSource quoteL198: R-CLIP-opt (ours) │ Generated report │ 1% │ 0.848 │ 0.780 |
| 2025 | R-CLIP-opt proposed | Accuracy | 0.780 | subset=1% · backbone=CLIP | CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest RadiographsSource quoteL198: R-CLIP-opt (ours) │ Generated report │ 1% │ 0.848 │ 0.780 |
| 2025 | RADAR proposed | BLEU-1 | 0.509 | view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384 | RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge InjectionSource quoteL224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports. |
| 2025 | RADAR proposed | METEOR | 0.450 | view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384 | RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge InjectionSource quoteL224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports. |
| 2025 | RADAR proposed | RG-F1 | 0.346 | view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384 | RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge InjectionSource quoteL224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports. |
| 2025 | RADAR proposed | 14-observation macro-average F1 | 0.460 | backbone=BLIP-3 · beam-width=5 · resolution=384×384 | RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge InjectionSource quoteL288: (14)Macro Average │ 0.481 │ 0.474 │ 0.460 |