MIMIC-CXR

263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

68.772.676.580.32024M-FLAG: 69.5 (2023)DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained): 79.53 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 150 of 418 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MedMO (variant not specified) proposedCIDEr140.0Medical report generation; the cited prose does not specify the model variant or evalua…MedMO: Grounding and Understanding Multimodal Large Language Model for Medical Images
Source quote
L276: On MIMIC-CXR, the most widely-used benchmark for chest X-ray report generation, our model achieves outstanding results with a CIDEr score of 140.0 and ROUGE-L of 31.7%, substantially outperforming strong medical baselines including Fleming-VL-8B (132.5, 35.7%) and Lingshu-7B (109.4, 30.8%). While Fleming-VL-8B achieves a higher ROUGE-L, our superior CIDEr score indicates better semantic coherence and clinical relevance. Most notably, the RaTE score of 57.1% and remarkable Semb score of 50.0% demonstrate that MedMO generates reports with high clinical accuracy and semantic fidelity.
2026RN50(KAN) + KAN-Map (K) proposedIoU0.069backbone=ResNet-50 with KAN head · backbone_status=pretrained and frozen · explanation_method=KAN-MapKANEx: Translating Kolmogorov-Arnold Networks' Interpretability to Medical Explainability
Source quote
L144: 0.060 │ -- │ 0.069
2026RN50(rKAN) + KAN-Map (K) proposedIoU0.076backbone=ResNet-50 with RationalKAN head · backbone_status=pretrained and frozen · explanation_method=KAN-MapKANEx: Translating Kolmogorov-Arnold Networks' Interpretability to Medical Explainability
Source quote
L150: 0.061 │ -- │ 0.076
2026RN50(KAN) + KAN-Map (K) proposedFaithfulness9.116backbone=ResNet-50 with KAN head · backbone_status=pretrained and frozen · explanation_method=KAN-MapKANEx: Translating Kolmogorov-Arnold Networks' Interpretability to Medical Explainability
Source quote
L147: 3.893 │ -- │ 9.116
2026DRRG proposedBLEU-40.210denoising-steps=72 · sequence-length=100DRRG: A Discrete Diffusion Framework for Radiology Report Generation
Source quote
L355: NLG Metrics: The NLG results on MIMIC-CXR and CheXpert Plus are reported in Table~\ref{tab:mimic_nlg} and Table~\ref{tab:chex_plus}. On MIMIC-CXR, DRRG achieves the best performance on BLEU-2, BLEU-3, BLEU-4, and ROUGE-L, with scores of 0.332, 0.259, 0.210, and 0.343, respectively. It also obtains the second-best BLEU-1 score of 0.452, slightly behind REVTAF-RRG~\cite{zhou2025learnable}. Compared with recent LLM-based RRG methods, DRRG achieves stronger NLG performance with a substantially smaller 0.6B text decoder, whereas the listed LLM-based competitors use text decoders with 7B or more parameters. On CheXpert Plus, DRRG achieves the best BLEU-4 score and a competitive ROUGE-L of 0.265. These results demonstrate the effectiveness of DRRG, suggesting that DLLMs provide a strong alternative to conventional AR-based RRG models.
2026ConRad (sentence-level) proposedECE0.239granularity=sentence-levelCalibrated Confidence Expression for Radiology Report Generation
Source quote
L103: ConRad │ 0.239 {[0.225, 0.253]} │ 0.633 {[0.620, 0.647]} │ 0.262 {[0.250, 0.274]}
2026ConRad (sentence-level) proposedAUROC0.633granularity=sentence-levelCalibrated Confidence Expression for Radiology Report Generation
Source quote
L103: ConRad │ 0.239 {[0.225, 0.253]} │ 0.633 {[0.620, 0.647]} │ 0.262 {[0.250, 0.274]}
2026ConRad (sentence-level) proposedGREEN0.262granularity=sentence-levelCalibrated Confidence Expression for Radiology Report Generation
Source quote
L103: ConRad │ 0.239 {[0.225, 0.253]} │ 0.633 {[0.620, 0.647]} │ 0.262 {[0.250, 0.274]}
2026CLEAR (MedGemma, Blur) proposedAUPRC90.23%split: testVisually Irrelevant Hallucinations in Medical Vision-Language Models
Source quote
L37: CXR, CLEAR improves AUPRC from 85.10% to 90.23%. Its
2026RAD-DINO image-only configuration proposedAUROC (macro)0.637split: patient-groupedLeakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification
Source quote
L873: gain 0.025 and 0.027 (AUROC 0.637 and 0.650; RAD-DINO
2026RAD-DINO early-fusion configuration proposedAUROC (macro)0.650split: patient-groupedLeakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification
Source quote
L873: gain 0.025 and 0.027 (AUROC 0.637 and 0.650; RAD-DINO
2026RAD-DINO image configuration proposedF2 (macro)+0.047split: patient-groupedLeakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification
Source quote
L877: 0.047 F2 and 0.099 AUROC (p = 0.008 and p = 0.005), and
2026RAD-DINO and time-aligned history fusion proposedAUROC (macro)0.766split: patient-groupedLeakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification
Source quote
L908: patient-separated A/C models in Table IV (0.766 and 0.762;
2026RAD-DINO and time-aligned history fusion proposedAUROC (macro)0.762split: patient-groupedLeakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification
Source quote
L908: patient-separated A/C models in Table IV (0.766 and 0.762;
2026Selected EHR-only configuration proposedF2 (macro)0.394split: recordLeakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification
Source quote
L934: over the patient split (0.394 vs. 0.373), and the margins of
2026Selected EHR-only configuration proposedF2 (macro)0.373split: patient-groupedLeakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification
Source quote
L946: (0.373) by 0.065 F2 and 0.142 AUROC and the 11 pathology
2026RAD-DINO image-only configuration proposedAUROC (macro)0.722split: patient-groupedLeakage- and Label-Aware Benchmarking of Class-Imbalance Strategies for Multimodal Chest X-Ray and EHR Classification
Source quote
L945: (0.438, AUROC 0.722) exceeds the released EHR variables
2026FairLLaVA-All proposedAge-group RadGraph-F1 fairness gap5.60Age-group gap; evaluation aggregates over subgroups of the other demographic attributes…FairLLaVA: Fairness-Aware Parameter-Efficient Fine-Tuning for Large Vision-Language Assistants
Source quote
L680: 0.59 │ 1.01 │ 5.60 │ 12.29
2026FairLLaVA-All proposedOverall GREEN34.32Overall performance score; higher is better.FairLLaVA: Fairness-Aware Parameter-Efficient Fine-Tuning for Large Vision-Language Assistants
Source quote
L682: 34.85 │ 13.92 │ 28.52 │ 34.32
2026LePaX proposedBLEU-40.253Report-generation evaluation; the paper reports BLEU-4 / METEOR / ROUGE in that order.Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report Generation
Source quote
L341: On MIMIC-CXR, it achieves BLEU-4 / METEOR / ROUGE scores of 0.253 / 0.336 / 0.380, surpassing previous encoder–decoder, transformer, and LLM-based methods.
2026LePaX proposedRadGraph F1 (RG_F1)0.346Clinical metric evaluation on MIMIC-CXR.Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report Generation
Source quote
L439: 0.346
2026LePaX (Ours-1920) proposedVision Tokens128 tokensresolution=up to 1920×1920Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report Generation
Source quote
L591: 128 │ 2.7s │ 46GB
2026Graph-Supervised Hierarchical Clinical Alignment (full model; 3B, ablation configuration 10) proposedB@40.143params=3B · backbone=3B · alignment-components=ICSM, DCSR, ICDM, DCNR, IMSCGraph-Supervised Hierarchical Clinical Alignment for Radiology Report Generation with Large Language Models
Source quote
L476: 10 │ 3B │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ \checkmark │ 0.427 │ 0.143 │ 0.167 │ 0.305 │ 1.145
2026IMT-CXR proposedBL-138.6split: testA unified multi-task framework enables interpretable chest radiograph analysis
Source quote
L688: Ours │ 38.6 │ 13.1 │ 16.7 │ 27.5 │ 42.8 │ 31.5 │ 33.1
2026CompDiff proposedFID64.3split: test · seeds=3 · training_steps=up to 30000CompDiff: Hierarchical Compositional Diffusion for Fair and Zero-Shot Intersectional Medical Image Generation
Source quote
L131: Table~\ref{tab:overall_and_equity} compares CompDiff against baselines across chest X-ray and fundus modalities. CompDiff achieves the best FID on both modalities (64.3 chest, 54.6 fundus). While FairDiffusion achieves slightly lower FID-RadImageNet on chest (6.2 vs 6.8), CompDiff outperforms on disease classification AUROC (0.82 vs 0.74), indicating better clinical feature alignment. MS-SSIM values remain in the acceptable range (0.25--0.75) for all models, confirming neither overfitting nor generation failure. Sex accuracy remains near-perfect across all methods. Slightly reduced race accuracy and increased age RMSE are expected trade-offs from HCN conditioning, offset by improved subgroup-level fairness below.
2026FINO proposedAUROC81.8split: test · params=2.7M label-supervised · subset=IID; 14 pathology labels · backbone=DINOv3 ViT-L/16Who Needs Labels? Adapting Vision Foundation Models With the Metadata You Already Have
Source quote
L201: \bf FINO (ours) │ 2.7M │ {\color{cyan}\Snow} │ {\bf 61.2} │ {\bf 53.1} │ \bf{52.9} │ {\bf 81.8}
2026Bayesian Pairwise Merging (BPM) proposed non-standard sliceMacro decided win rate against uniform merge (RS)91.7%split: test · feedback-budget=100The Missing Coefficients: Bayesian Pairwise Merging for Model Personalization
Source quote
L321: RS │ \mrbhldiff{91.7}{50}\,\mrbci{90.3, 93.1} │ \mrbhldiff{88.4}{50}\,\mrbci{86.2, 90.4} │ \mrbhldiff{77.1}{50}\,\mrbci{74.7, 79.3} │ \mrbhldiff{78.7}{50}\,\mrbci{76.6, 80.7} │ \mrbhldiff{64.3}{50}\,\mrbci{62.5, 66.1} │ \mrbhldiff{76.1}{50}\,\mrbci{74.4, 77.8}
2026Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposedAUPRC87.78%split: testCase-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive Supervision
Source quote
L226: S3: Case + Evidence + Claim │ 97.43 │ 87.78 │ 78.72 │ 92.03 │ 0.060
2026Evidence-only baseline (S2: Evidence + Claim; shared ModernBERT-large verifier) proposedAUPRC35.11%split: testCase-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive Supervision
Source quote
L225: S2: Evidence + Claim │ 82.63 │ 35.11 │ 62.79 │ 87.53 │ 0.255
2026Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposedAUROC97.43%split: testCase-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive Supervision
Source quote
L226: S3: Case + Evidence + Claim │ 97.43 │ 87.78 │ 78.72 │ 92.03 │ 0.060
2026Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposedAUROC55.62%split: testCase-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive Supervision
Source quote
L1297: AUROC │ 97.43 ± 0.27 [97--98] │ 97.24 ± 0.33 [97--98] │ 55.62 ± 1.50 [53--59]
2026Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposedAUPRC74.18%split: testCase-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive Supervision
Source quote
L1298: AUPRC │ 87.78 ± 1.56 [85--91] │ 74.18 ± 3.20 [68--80] │ 21.73 ± 1.54 [19--25]
2026AR-RRG proposedB-40.152split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedB-10.425split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedB-20.292split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedB-30.210split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedRG-L0.322split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026DiTPO proposedF10.516data_setting=full-dataRethinking the Efficiency and Effectiveness of Reinforcement Learning for Radiology Report Generation
Source quote
L233: Table \ref{table:mimic_results} details the comparative results on the MIMIC-CXR. Our DiTPO model with full-data establishes a new SOTA in clinical accuracy, achieving a F1 score of 0.516. This performance surpasses our basic GRPO framework (0.507) and previous leading RL methods like OISA (0.504), as well as strong SFT baselines such as SS-ACL (0.505), validating the effectiveness of directly optimizing for diagnostic entities.
2026PCXR-Copilot pulmonary edema intensity index proposedROC AUC for grade 3 versus grade 0 pulmonary edema0.681no-retraining-or-fine-tuningPCXR-Copilot: Device-aware pediatric chest radiographic analysis with segmentation, suppression, and edema-related cues
Source quote
L428: graphs) and grade 3 (alveolar edema; 82 radiographs), the AUC was 0.681 (95% CI
2026RIHA (Report-Image Hierarchical Alignment Transformer) proposedBLEU-10.385Reported benchmark result for RIHA on MIMIC-CXR; the split is not specified in the cite…RIHA: Report-Image Hierarchical Alignment for Radiology Report Generation
Source quote
L146: On the more challenging MIMIC-CXR dataset, RIHA demonstrates competitive results, achieving the best scores in BLEU-1 (0.385), BLEU-2 (0.251), METEOR (0.159), and ROUGE-L (0.293). Our method shows consistent improvements over recent approaches including M2KT~\cite{yang2023radiology} (4.6% improvement on BLEU-1), CAMANET~\cite{wang2024camanet} (4.9% improvement on BLEU-1), and COMG~\cite{gu2024complex} (11.6% improvement on BLEU-1).
2026RIHA (Report-Image Hierarchical Alignment Transformer) proposedROUGE-L0.293Reported benchmark result for RIHA on MIMIC-CXR; the split is not specified in the cite…RIHA: Report-Image Hierarchical Alignment for Radiology Report Generation
Source quote
L146: On the more challenging MIMIC-CXR dataset, RIHA demonstrates competitive results, achieving the best scores in BLEU-1 (0.385), BLEU-2 (0.251), METEOR (0.159), and ROUGE-L (0.293). Our method shows consistent improvements over recent approaches including M2KT~\cite{yang2023radiology} (4.6% improvement on BLEU-1), CAMANET~\cite{wang2024camanet} (4.9% improvement on BLEU-1), and COMG~\cite{gu2024complex} (11.6% improvement on BLEU-1).
2026LLaVA-TA proposedRadGraph F131.1fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · evaluation_setting=in-distributionRethinking Radiology Report Generation: From Narrative Flow to Topic-Guided Findings
Source quote
L601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs.
2026MEDA (QMS+PDI) proposedAccuracy79.4%multi-round · backbone=LLaVA-Med-1.5 · question_set=MedHEval · method_variant=QMS+PDIMEDA: Medical-Oriented Activation Editing for Hallucination Mitigation in Medical Large Vision-Language Model
Source quote
L398: 79.4
2026ESC-RL proposedF10.608Clinical efficacy (CE) comparison across 14 diseases; split not specified in the cited …Enhancing Reinforcement Learning for Radiology Report Generation with Evidence-aware Rewards and Self-correcting Preference Learning
Source quote
L317: ESC-RL (Ours) │ 0.632 │ 0.625 │ 0.608 │ 0.299 │ 0.311 │ 0.295
2026CheXOne-drafted reports proposedcases with reports judged comparable to or better than resident-written reports55\%split: test · study=radiologist reader study · sample-size=80 radiographs · radiologists=11A Reasoning-Enabled Vision-Language Foundation Model for Chest X-ray Interpretation
Source quote
L18: A clinical reader study demonstrates that CheXOne-drafted reports are comparable to or better than resident-written reports in 55% of cases, while effectively addressing clinical indications and enhancing both report writing and CXR interpretation efficiency.
2026MedCTA proposedP@1 precision80.24%subset=5×200Clinical Trajectory Alignment for Medical Vision-Language Pre-training
Source quote
L398: Ours │ 80.24 │ 79.08 │ 75.68 │ 65.82 │ 69.13 │ 68.63 │ 67.23 │ 63.01
2026RadFusion (GPT-5 rewriter, default instruction) proposedAUC-ROC (macro average).90rewriter=GPT-5 · instruction=defaultRadFusion: Towards Threshold-Controllable Radiology Report Generation
Source quote
L194: GPT-5 │ default │ .93 │ .92 │ .92 │ .84 │ .92 │ .91 │ .88 │ .90 │ .88 │ .90 │ .90 │ .89 │ .93 │ .90
2025GPT-4o, Thought Graph Traversal (TGT) proposedBLEU-49.84%split: test · backbone=GPT-4oSimple Radiology VLLM Test-time Scaling with Thought Graph Traversal
Source quote
L200: TGT │ 29.25 │ 15.81 │ 8.95 │ 9.84 │ 14.12 │ 26.50
2025HuatuoGPT-Vision, Thought Graph Traversal (TGT) proposedBLEU-411.34%split: test · backbone=HuatuoGPT-VisionSimple Radiology VLLM Test-time Scaling with Thought Graph Traversal
Source quote
L208: TGT │ 32.99 │ 18.89 │ 10.85 │ 11.34 │ 14.36 │ 27.06
2025HiMed-3B proposedRATE (RaTEScore)0.544params=3BBeyond N-grams: A Hierarchical Reward Learning Framework for Clinically-Aware Medical Report Generation
Source quote
L272: HiMed-3B (\S) │ 0.292 │ 0.156 │ 0.088 │ 0.052 │ 0.289 │ 0.079 │ 0.271 │ 0.220 │ 0.544
2025MoColl + tuned VQA model proposedROUGE-L0.2349fine-tunedMoColl: Agent-Based Specific and General Model Collaboration for Image Captioning
Source quote
L218: MoColl + tuned VQA model (Ours) │ \bf{0.2749} │ \bf{0.1454} │ \bf{0.0897} │ \bf{0.0655} │ \bf{0.1126} │ \bf{0.2349} │ \bf{0.0932}
2025MoColl + aligned VLM proposedROUGE-L0.1906fine-tunedMoColl: Agent-Based Specific and General Model Collaboration for Image Captioning
Source quote
L217: MoColl + aligned VLM (Ours) │ 0.2515 │ 0.1290 │ 0.0746 │ 0.0456 │ 0.0947 │ 0.1906 │ 0.0566
2025DLDM (disentangled latent diffusion model) proposedEffectiveness Accuracy89.2%split: test · intervention=do(A=black)AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual Analysis
Source quote
L605: DLDM │ 89.2 │ 92.0 │ 93.7
2025Hulu-Med-7B proposedRaTEScore57.0model=Hulu-Med-7B · params=7BHulu-Med: A Transparent Generalist Model towards Holistic Medical Vision-Language Understanding
Source quote
L31: We evaluated Hulu-Med on three standard 2D MRG benchmarks, including MIMIC-CXR, CheXpert, and IU X-ray, and assessed performance using both standard metrics (BLEU, ROUGE, METEOR) and the clinically-oriented metric RaTEScore~\cite{demner2015preparing,zhao2024ratescore,irvin2019chexpert,johnson2019mimic} (\textcolor{blue}{Fig.~\ref{fig:2d_results}a-b}). All Hulu-Med variants achieved state-of-the-art performance across these benchmarks. Notably, on MIMIC-CXR, Hulu-Med-7B attained a RaTEScore of 57.0, substantially exceeding the previous best model, MedGemma-4B/27B (RaTEScore 51.3) (\textcolor{blue}{Fig.~\ref{fig:2d_results}b}). This result is clinically significant, as MedGemma's score corresponded to 81% of its reports leading to the same or superior clinical decisions compared to original reports, as judged by a board-certified radiologist~\cite{sellergren2025medgemma}. Our results further demonstrate that larger model size does not guarantee superior MRG performance, as evidenced by Hulu-Med-7B occasionally surpassing its 32B counterpart, a pattern also observed with MedGemma. This finding underscores that domain-specific pretraining is critical for specialized tasks like MRG, affirming the necessity of developing medical vision-language models.
2025Synthetic+Real mix model (maximal synthetic data) proposedAUROC0.770split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrainedImproving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic Data
Source quote
L135: The synthetic+real model with maximal data achieved an AUROC of 0.770 (CI: 0.762-0.778) for the multi-label classification task on the in-distribution MIMIC-CXR test set.
2025IDEFICS+ADA-Steal proposedRG-L21.4fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100Medical Multimodal Model Stealing Attacks via Adversarial Domain Alignment
Source quote
L285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3
2025IDEFICS+ADA-Steal proposedBert-S48.0fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100Medical Multimodal Model Stealing Attacks via Adversarial Domain Alignment
Source quote
L285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3
2025IDEFICS+ADA-Steal proposedRad-S14.1fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100Medical Multimodal Model Stealing Attacks via Adversarial Domain Alignment
Source quote
L285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3
2025MedUnifier (w TIG) proposedBLEU-1 (BL-1)41.5split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MedUnifier (w TIG) proposedBLEU-4 (BL-4)12.9split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MedUnifier (w TIG) proposedMETEOR (MTR)22.7split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MedUnifier (w TIG) proposedROUGE-L (RG-L)34.0split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MedUnifier proposedFID (lower is better)46.2FID uses the MIMIC-CXR pre-training dataset as the reference. The table does not explic…MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L268: LLM-CXR\cite{lee2023llm} │ 22.8 │ MedUnifier │ 46.2
2025MVMAE proposedmacro-AUROC over 14 CheXpert labels0.75split: test · fine-tuned · view=frontal · labels=5,000Leveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L137: Frontal │ 0.75 │ 0.65
2025MVMAE proposedmacro-AUROC over 14 CheXpert labels0.73split: test · fine-tuned · view=lateral · labels=5,000Leveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L138: Lateral │ 0.73 │ 0.65
2025MVMAE proposedmacro-AUROC over 14 CheXpert labels0.75split: test · fine-tuned · view=frontal+lateral ensemble · fusion=late · labels=5,000Leveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L139: Ensemble │ 0.75 │ 0.69 \multirow{3}{*}{Contrastive}
2025SS-ACL proposedBLEU-40.144split: test · test-samples=3858Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report Generation
Source quote
L447: {\color[HTML]{C00000} 0.144}
2025SS-ACL proposedClinical efficacy macro F10.505split: test · categories=14 thoracic diseases · test-samples=3858 · clinical-labeler=CheXbertSelf-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report Generation
Source quote
L453: {\color[HTML]{C00000} 0.505}
2025MedAlign proposedRadGraph F110.92peft · backbone=LLaVA-Med-1.5 · fine-tuning=without LoRAEnhancing Medical Large Vision-Language Models via Alignment Distillation
Source quote
L441: MedAlign\xspace │ 4.51 │ 18.43 │ 20.80 │ 86.00 │ 25.67 │ 10.92 │ 42.03
2025DDaTR (SwinT-B) proposedF1_macro (Clinical Efficacy)0.441split: test · backbone=SwinT-B · averaging=macroDDaTR: Dynamic Difference-aware Temporal Residual Network for Longitudinal Radiology Report Generation
Source quote
L313: Ours │ 0.438 │ 0.465 │ 0.441 (+0.049) │ 0.113 │ 0.162 │ 0.272
2025AM-MRG proposedBLEU-40.136NLG report-generation metric on MIMIC-CXR; split and averaging are not specified in the…Activating Associative Disease-Aware Vision Token Memory for LLM-Based X-Ray Report Generation
Source quote
L344: In the MIMIC-CXR dataset, AM-MRG secures the best results for all metrics except CIDEr, with scores of 0.426 for BLEU-1, 0.271 for BLEU-2, 0.187 for BLEU-3, 0.136 for BLEU-4, 0.291 for ROUGE-L, and 0.174 for METEOR. Additionally, BLEU-4 has improved by 8.8% relative to R2GenGPT~\cite{Wang2023R2GenGPT}.
2025AM-MRG proposedF10.484Clinical Efficacy (CE) metric on MIMIC-CXR; split and averaging are not specified in th…Activating Associative Disease-Aware Vision Token Memory for LLM-Based X-Ray Report Generation
Source quote
L349: As depicted in Tables \ref{tab:CE_Metrics_Mimic_CXR_results} and \ref{tab:CE_Metrics_CheXpert_Plus_results}, we have evaluated the accuracy of our model, AM-MRG, in delineating clinical abnormalities by reporting the Clinical Efficacy (CE) metrics alongside seven other models across two distinct datasets. On the MIMIC-CXR dataset, AM-MRG yielded impressive results with Precision, Recall, and F1 scores of 0.555, 0.429, and 0.484, respectively. Notably, the Recall and F1 scores surpass those of the competing models, with the F1 score a remarkable 19.5% higher than the second-best model, CoFE~\cite{li2025CoFE}. In the Chexpert Plus dataset, AM-MRG took the lead in all three metrics, achieving Precision, Recall, and F1 scores of 0.396, 0.318, and 0.336, respectively. The F1 score represented a significant 16.6% improvement over the runner-up, Token-Mixer~\cite{Yang2024Token-Mixer}, signifying a substantial edge.
2025DiffRGenNet proposedF10.483split: testDiffRGenNet: Difference-aware Medical Report Generation
Source quote
L286: 0.483
2025MedAlign proposedF195.25%split: test · params=7B · backbone=LLaVA-Med-1.5 7BMedAlign: A Synergistic Framework of Multimodal Preference Optimization and Federated Meta-Cognitive Reasoning
Source quote
L417: MedAlign │ 95.64 │ 96.47 │ 95.25 │ 94.36 │ 22.99 │ 27.89 │ 16.33 │ 2.29
2025ARRA (text-generation-only LLM initialization) proposedFID5.30split: test · subset=1,000 pairs · resolution=512×512Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation Alignment
Source quote
L309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576.
2025ARRA (text-generation-only LLM initialization) proposedCLIP-Score0.4532split: test · subset=1,000 pairs · backbone=CLIP · resolution=512×512Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation Alignment
Source quote
L309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576.
2025ARRA-Adapt (general image-generation pretrained LLM initialization) proposedFID4.15split: test · subset=1,000 pairs · resolution=512×512Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation Alignment
Source quote
L309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576.
2025ARRA-Adapt (general image-generation pretrained LLM initialization) proposedCLIP-Score0.4576split: test · subset=1,000 pairs · backbone=CLIP · resolution=512×512Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation Alignment
Source quote
L309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576.
2025MeDiM proposedFID16.60split: testDiscrete Diffusion Models with MLLMs for Unified Medical Multimodal Generation
Source quote
L34: 1) For medical image generation, MeDiM achieves state-of-the-art Frechet Inception Distances (FID) on the MIMIC-CXR~\citep{johnson2019mimic} and PathGen~\citep{sun2024pathgen} datasets, respectively (Tab.~\ref{tab_1} and Tab.~\ref{tab_2}; 16.60 FID and 24.19 FID), generating high-fidelity medical images across different modalities (Fig.~\ref{fig_qual}; robust and high visual quality).
2025MeDiM proposed non-standard sliceMETEOR (table label: MTR)0.265split: testDiscrete Diffusion Models with MLLMs for Unified Medical Multimodal Generation
Source quote
L275: MeDiM (Ours) │ MLLM │ 0.328 │ 0.185 │ 0.109 │ 0.265 │ 0.297 │ 0.185 │ 0.084 │ 0.037 │ 0.258 │ 0.226
2025CURV proposedBLEU-3 (B-3)9.85params=3BCURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report Generation
Source quote
L210: 9.85
2025CURV proposedRadGraph F119.54params=3BCURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report Generation
Source quote
L277: 19.54
2025MedOrch proposedMacro AUC61.2%Chest X-ray analysis; macro-level metric.MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible Extensibility
Source quote
L4: Healthcare decision-making represents one of the most challenging domains for Artificial Intelligence (AI), requiring the integration of diverse knowledge sources, complex reasoning, and various external analytical tools. Current AI systems often rely on either task-specific models, which offer limited adaptability, or general language models without grounding with specialized external knowledge and tools. We introduce \texttt{MedOrch}\xspace, a novel framework that orchestrates multiple specialized tools and reasoning agents to provide comprehensive medical decision support. \texttt{MedOrch}\xspace employs a modular, agent-based architecture that facilitates the flexible integration of domain-specific tools without altering the core system. Furthermore, it ensures transparent and traceable reasoning processes, enabling clinicians to meticulously verify each intermediate step underlying the system’s recommendations. We evaluate \texttt{MedOrch}\xspace across three distinct medical applications: Alzheimer's disease diagnosis, chest X-ray interpretation, and medical visual question answering, using authentic clinical datasets. The results demonstrate \texttt{MedOrch}\xspace's competitive performance across these diverse medical tasks. Notably, in Alzheimer's disease diagnosis, \texttt{MedOrch}\xspace achieves an accuracy of 93.26%, surpassing the state-of-the-art baseline by over four percentage points. For predicting Alzheimer's disease progression, it attains a 50.35% accuracy, marking a significant improvement. In chest X-ray analysis, \texttt{MedOrch}\xspace exhibits superior performance with a Macro AUC of 61.2% and a Macro F1-score of 25.5%. Moreover, in complex multimodal visual question answering (Image+Table), \texttt{MedOrch}\xspace achieves an accuracy of 54.47%. These findings underscore \texttt{MedOrch}\xspace's potential to advance healthcare AI by enabling reasoning-driven tool utilization for multimodal medical data processing and supporting intricate cognitive tasks in clinical decision-making.
2025MedOrch proposedMacro F1-score25.5%Chest X-ray analysis; macro-level metric.MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible Extensibility
Source quote
L4: Healthcare decision-making represents one of the most challenging domains for Artificial Intelligence (AI), requiring the integration of diverse knowledge sources, complex reasoning, and various external analytical tools. Current AI systems often rely on either task-specific models, which offer limited adaptability, or general language models without grounding with specialized external knowledge and tools. We introduce \texttt{MedOrch}\xspace, a novel framework that orchestrates multiple specialized tools and reasoning agents to provide comprehensive medical decision support. \texttt{MedOrch}\xspace employs a modular, agent-based architecture that facilitates the flexible integration of domain-specific tools without altering the core system. Furthermore, it ensures transparent and traceable reasoning processes, enabling clinicians to meticulously verify each intermediate step underlying the system’s recommendations. We evaluate \texttt{MedOrch}\xspace across three distinct medical applications: Alzheimer's disease diagnosis, chest X-ray interpretation, and medical visual question answering, using authentic clinical datasets. The results demonstrate \texttt{MedOrch}\xspace's competitive performance across these diverse medical tasks. Notably, in Alzheimer's disease diagnosis, \texttt{MedOrch}\xspace achieves an accuracy of 93.26%, surpassing the state-of-the-art baseline by over four percentage points. For predicting Alzheimer's disease progression, it attains a 50.35% accuracy, marking a significant improvement. In chest X-ray analysis, \texttt{MedOrch}\xspace exhibits superior performance with a Macro AUC of 61.2% and a Macro F1-score of 25.5%. Moreover, in complex multimodal visual question answering (Image+Table), \texttt{MedOrch}\xspace achieves an accuracy of 54.47%. These findings underscore \texttt{MedOrch}\xspace's potential to advance healthcare AI by enabling reasoning-driven tool utilization for multimodal medical data processing and supporting intricate cognitive tasks in clinical decision-making.
2025LANCE proposedCPG0.81resolution=512×512 · intervention=do(sex)Leveraging Vision-Language Foundation Models to Reveal Hidden Image-Attribute Relationships in Medical Imaging
Source quote
L97: Ours │ 0.81 │ 0.89 │ 0.75
2025LANCE proposedCPG0.89resolution=512×512 · intervention=do(disease)Leveraging Vision-Language Foundation Models to Reveal Hidden Image-Attribute Relationships in Medical Imaging
Source quote
L97: Ours │ 0.81 │ 0.89 │ 0.75
2025LANCE proposedCPG0.75resolution=512×512 · intervention=do(race)Leveraging Vision-Language Foundation Models to Reveal Hidden Image-Attribute Relationships in Medical Imaging
Source quote
L97: Ours │ 0.81 │ 0.89 │ 0.75
2025CXR-LanSE proposed non-standard slicenumber of distinct radiological patterns899 patternsPatterns discovered using the interpretability framework adapted for medical data.Interpretable Evaluation of AI-Generated Content with Language-Grounded Sparse Encoders
Source quote
L36: CXR-LanSE extends our content analysis approach to medical imaging by systematically discovering clinical visual patterns in chest X-ray images. Using the same interpretability framework adapted for medical data, CXR-LanSE identifies 899 distinct radiological patterns from MIMIC-CXR datasets and AI-generated medical images. These patterns capture clinically meaningful features ranging from anatomical landmarks to pathological findings and medical devices. To validate the clinical relevance of discovered patterns, we conducted evaluations with two expert radiologists who assessed pattern-image correspondence on randomly selected neuron-image pairs. Each pair consisted of a CXR-LanSE pattern description and a chest X-ray image that activated the corresponding neuron. The radiologists judged whether the automated interpretation accurately captured clinically meaningful features present in the image.
2025MCA-RG (7B; listed as Ours) proposedROUGE-L (RG-L)0.300params=7BMCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report Generation
Source quote
L138: Ours │ 7B │ 0.411 │ 0.256 │ 0.175 │ 0.128 │ 0.163 │ 0.300
2025MCA-RG (7B; listed as Ours) proposedExample-based F10.408split: test · params=7B · scores=CE · averaging=example-basedMCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report Generation
Source quote
L172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt]
2025MCA-RG (7B; listed as Ours) proposedMacro-based F10.335split: test · params=7B · scores=CE · averaging=macro-basedMCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report Generation
Source quote
L172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt]
2025ChexGen proposedFID (CLIP features)0.89split: test · backbone=CLIP · sample-size=3500 cases · feature-extractor=CLIPA Generative Foundation Model for Chest Radiography
Source quote
L76: We assessed fidelity by calculating the FID (lower is better) between synthetic and real CXRs, extracting features from a pretrained general-purpose model (CLIP~\cite{radford2021learning}) and a domain-specific chest radiograph classifier (XRV~\cite{Cohen2022xrv}). ChexGen achieved substantially better fidelity with lower FID scores compared to MINIM-CXR~\cite{wang2024self} and RoentGen~\cite{chambon2022roentgen} (CLIP: 0.89 vs. 9.63 and 4.42; XRV: 0.57 vs. 8.29 and 6.80) (\textbf{\cref{fig:figure2}a}, p < 0.001). These results demonstrate that ChexGen better captures the distribution of real-world chest radiographs.
2025ChexGen-balanced DenseNet121 model proposedWeighted F1-score for worst-performing gender group0.387split: test · model=DenseNet121 · subgroup=worst-performing gender group · training-data=ChexGen-balancedA Generative Foundation Model for Chest Radiography
Source quote
L160: In addition to detecting model bias, we explored whether synthetic data could be used to further mitigate the observed bias. Using ChexGen, we generated additional training samples for underrepresented demographic subgroups until their representation matched that of the majority groups. Consequently, the augmented training data led to substantial improvements in model fairness across all demographic dimensions. For instance, the F1-Scores increased significantly for the worst group (gender: 0.338 to 0.387, race: 0.321 to 0.394, age: 0.363 to 0.419), while performance gaps between best and worst groups narrowed considerably with a relative reduction of up to 60% (gender: 2.5% to 1.6%, race: 2.9% to 1.2%, age: 2.3% to 1.2%) (\textbf{\cref{fig:figure6}d}). These results highlight the potential of CheXGen for generating synthetic data to enhance model fairness by detecting and mitigating bias.
2025MAIRA-2 + CCD proposedRadGraph-F119.01Radiology report generation; CCD applied to MAIRA-2.CCD: Mitigating Hallucinations in Radiology MLLMs via Clinical Contrastive Decoding
Source quote
L478: \(+\) CCD │ 20.70 │ 2.10 │ 51.62 │ 19.01 │ 17.58 │ 53.32 │ 17.50 │ 27.05 │ 16.02
2025Domain-specific tokenizer (Specific) proposedR-L0.344split: test · vocabulary-size=9.1kSpecialised or Generic? Tokenization Choices for Radiology Language Models
Source quote
L167: Specific │ \ding{55} │ 9.1k │ 0.273 │ 0.364 │ 0.344 │ 0.514 │ 0.604 │ 0.270 │ 0.813
2025DCFG (ω_aff=2.5, ω_inv=1.2) proposedROC-AUC (intervened Sex)99.9omega-aff=2.5 · omega-inv=1.2 · intervention=do(sex) · target-label=pleural-effusionFactored Classifier-Free Guidance
Source quote
L658: \omega-aff=2.5, \omega-inv=1.2 │ \inter{99.9 / +7.5} │ \uninter{74.9 / -0.7} │ \uninter{90.1 / +1.3} │ 0.199 │ 0.260
2025DCFG (ω_aff=2.5, ω_inv=1.2) proposedROC-AUC (invariant Race)74.9attribute=Race (invariant) · omega-aff=2.5 · omega-inv=1.2 · intervention=do(sex)Factored Classifier-Free Guidance
Source quote
L658: \omega-aff=2.5, \omega-inv=1.2 │ \inter{99.9 / +7.5} │ \uninter{74.9 / -0.7} │ \uninter{90.1 / +1.3} │ 0.199 │ 0.260
2025OTDRG proposedBLEU-10.411Report-generation comparison table; table states results are from the original papers.Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMs
Source quote
L277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295
2025OTDRG proposedBLEU-40.128Report-generation comparison table; table states results are from the original papers.Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMs
Source quote
L277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295
2025OTDRG proposedMETEOR0.164Report-generation comparison table; table states results are from the original papers.Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMs
Source quote
L277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295
2025OTDRG proposedROUGE-L0.295Report-generation comparison table; table states results are from the original papers.Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMs
Source quote
L277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295
2025OTDRG proposedClinical efficacy F10.436disease-labels=14 · clinical-labeler=CheXbertBridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMs
Source quote
L277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295
2025RadVLM+RL (GRPO) proposedBERTScore (B-S)59.2split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findingsRadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement Learning
Source quote
L117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86
2025RadVLM+RL (GRPO) proposedGREEN (GRN)32.7split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findingsRadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement Learning
Source quote
L117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86
2025RadVLM+RL (GRPO) proposedRadCliQ (RCQ)0.86split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findingsRadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement Learning
Source quote
L117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86
2025CoCa-CXR, description-only generation proposedRadGraph F124.2%Generates descriptions only; CoCa-CXR and the compared models rely solely on images as …CoCa-CXR: Contrastive Captioners Learn Strong Temporal Structures for Chest X-Ray Vision-Language Understanding
Source quote
L127: Tab.~\ref{tab:mimic-cxr} presents report generation results on the MIMIC-CXR dataset \cite{johnson2019mimic}. CoCa-CXR predicts both FINDINGS and IMPRESSION sections, a more challenging task than FINDINGS alone \cite{bannur2023learning}. When generating only descriptions, it achieves a RadGraph F1 score of 24.2%, on par with large-scale models like Med-Gemini \cite{yang2024advancing}. Notably, PaliGemma-2 \cite{steiner2024paligemma} incorporates both images and the indication section as inputs, whereas CoCa-CXR and other models in Tab.~\ref{tab:mimic-cxr} rely solely on images; hence, we exclude its result for fair comparison.
2025CoCa-CXR, generating comparison descriptions proposedRadGraph F123.7%Generates comparison descriptions in addition to descriptions.CoCa-CXR: Contrastive Captioners Learn Strong Temporal Structures for Chest X-Ray Vision-Language Understanding
Source quote
L128: When also generating comparison descriptions, CoCa-CXR attains a RadGraph F1 score of 23.7%. Although this is slightly lower than description-only generation, our hypothesis is that, describing progression adds another dimension to report generation tasks, and with the current accuracy-level (65%) on temporal classification, one can obtain a similar level of benefit on Radgraph F1 by simply omitting comparisons in the generated reports. But still, as shown in Fig. \ref{fig:pos_vs_neg_order}, this is step forward in incorporating this progression dimension and towards real world application.
2025RRG-opt proposedBLEU20.157subset=3.70%CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest Radiographs
Source quote
L168: RRG-opt (ours) │ 3.70% │ 0.241 │ 0.157 │ 0.108 │ 0.078 │ 0.109 │ 0.239 │ 0.513
2025RRG-opt proposedBLEU30.108subset=3.70%CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest Radiographs
Source quote
L168: RRG-opt (ours) │ 3.70% │ 0.241 │ 0.157 │ 0.108 │ 0.078 │ 0.109 │ 0.239 │ 0.513
2025RRG-opt proposedBLEU40.078subset=3.70%CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest Radiographs
Source quote
L168: RRG-opt (ours) │ 3.70% │ 0.241 │ 0.157 │ 0.108 │ 0.078 │ 0.109 │ 0.239 │ 0.513
2025RRG-opt proposedROUGEL0.239subset=3.70%CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest Radiographs
Source quote
L168: RRG-opt (ours) │ 3.70% │ 0.241 │ 0.157 │ 0.108 │ 0.078 │ 0.109 │ 0.239 │ 0.513
2025R-CLIP-opt proposedAUC0.848subset=1% · backbone=CLIPCRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest Radiographs
Source quote
L198: R-CLIP-opt (ours) │ Generated report │ 1% │ 0.848 │ 0.780
2025R-CLIP-opt proposedAccuracy0.780subset=1% · backbone=CLIPCRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest Radiographs
Source quote
L198: R-CLIP-opt (ours) │ Generated report │ 1% │ 0.848 │ 0.780
2025RADAR proposedBLEU-10.509view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge Injection
Source quote
L224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports.
2025RADAR proposedMETEOR0.450view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge Injection
Source quote
L224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports.
2025RADAR proposedRG-F10.346view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge Injection
Source quote
L224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports.
2025RADAR proposed14-observation macro-average F10.460backbone=BLIP-3 · beam-width=5 · resolution=384×384RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge Injection
Source quote
L288: (14)Macro Average │ 0.481 │ 0.474 │ 0.460
2025RADAR proposed5-observation macro-average F10.567backbone=BLIP-3 · beam-width=5 · resolution=384×384RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge Injection
Source quote
L276: ^5Macro Average │ 0.551 │ 0.602 │ 0.567
2025Weighted Avg (W-Avg; PRM scores) proposedF1-CheXbert0.3575split: test · subset=full-unbalanced · strategy=weighted-average · generator=MAIRA-2 · candidates=128 · temperature=1.0Process Reward Models for Sentence-Level Verification of LVLM Radiology Reports
Source quote
L536: Our results (Figures~\ref{fig:bon_weighted_all} and \ref{fig:bon_nonweighted_all}) show that weighted strategies generally outperform non-weighted ones. For instance, Weighted Avg (W-Avg) using PRM scores improves F1-CheXbert by +5.0 points (0.3575 vs 0.3077 for non-weighted AvgProb) at N=128. Similarly, W-Avg boosts BERTScore by +0.001 points (0.8594 vs 0.8584) under the same conditions. The choice of N also impacts performance, with larger N generally leads to better results.
2025HTSC-CIF proposedMETEOR0.177split: testMedical Report Generation: A Hierarchical Task Structure-Based Cross-Modal Causal Intervention Framework
Source quote
L230: Ours │ 0.413 │ 0.264 │ 0.193 │ 0.139 │ 0.177 │ 0.305 │ 0.386
2025HTSC-CIF proposedROUGE-L0.305split: testMedical Report Generation: A Hierarchical Task Structure-Based Cross-Modal Causal Intervention Framework
Source quote
L230: Ours │ 0.413 │ 0.264 │ 0.193 │ 0.139 │ 0.177 │ 0.305 │ 0.386
2025Disease-Aware Dual-Stage Framework (Ours; DASTs + DVAF + DMSR) proposedBLEU40.131stage-1-data=480,000 image-text pairs · stage-1-supervision=14-category CheXpert labelsA Disease-Aware Dual-Stage Framework for Chest X-ray Report Generation
Source quote
L231: Ours │ -- │ 0.428 │ 0.272 │ 0.187 │ 0.131 │ 0.291 │ 0.232
2025Disease-Aware Dual-Stage Framework (Ours; DASTs + DVAF + DMSR) proposedROUGE-L0.291stage-1-data=480,000 image-text pairs · stage-1-supervision=14-category CheXpert labelsA Disease-Aware Dual-Stage Framework for Chest X-ray Report Generation
Source quote
L231: Ours │ -- │ 0.428 │ 0.272 │ 0.187 │ 0.131 │ 0.291 │ 0.232
2025Disease-Aware Dual-Stage Framework (Ours; DASTs + DVAF + DMSR) proposedCIDEr0.232stage-1-data=480,000 image-text pairs · stage-1-supervision=14-category CheXpert labelsA Disease-Aware Dual-Stage Framework for Chest X-ray Report Generation
Source quote
L231: Ours │ -- │ 0.428 │ 0.272 │ 0.187 │ 0.131 │ 0.291 │ 0.232
2025MLRG proposedmicro avg F10.505Clinical accuracy across 14 CheXpert-annotated observations; micro average. The cited t…Enhanced Contrastive Learning with Multi-view Longitudinal Data for Chest X-ray Report Generation
Source quote
L259: micro avg │ 0.523 │ 0.410 │ 0.460 │ 0.549 │ 0.468 │ 0.505 │ 0.522 │ 0.447 │ 0.481 │ 0.532 │ 0.474 │ 0.501
2025KIA proposedBLEU-40.138split: testKIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report Generation
Source quote
L535: Specifically, our KIA achieves 0.188 and 0.138
2025KIA proposedCIDEr0.316split: testKIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report Generation
Source quote
L538: Notably, our CIDEr scores of 0.641 and 0.316 on two datasets achieve considerable improvements of 9% and 6%, showing that reports generated by KIA are highly relevant to the image content and accurately reflect important information. This illustrates that the multitask implicit alignment we designed can effectively enhance the understanding of images and reports.
2025KIA proposed non-standard sliceF1-Score0.461split: test · clinical-labels=14 CheXpert abnormality categoriesKIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report Generation
Source quote
L477: 0.461
2025EMRRG proposedF10.395fine-tunedEMRRG: Efficient Fine-Tuning Pre-trained X-ray Mamba Networks for Radiology Report Generation
Source quote
L208: EMRRG │ Ours │ 0.421 │ 0.372 │ 0.395
2025XMedGPT with the clinical reasoning framework proposedKendall’s tau-b (consistency)0.479split: test · fine-tuned · training=SFT and DPO · annotation=Chest-Imagenome-derived regionsMulti-Modal Explainable Medical AI Assistant for Trustworthy Human-AI Collaboration
Source quote
L82: Training on the MIMIC-CXR dataset involved supervised fine-tuning (SFT) with 10,000 samples for long chain-of-thought reasoning, followed by reinforcement learning via Direct Preference Optimization (DPO) on 8,201 high/low-scoring report pairs. Evaluation on a test set annotated with Chest-Imagenome-derived regions revealed a 6.05% average improvement across clinical metrics (CheXpert F1, Radgraph F1, CheXpert Similarity) compared to non-reasoning baselines. DPO further refined report quality, elevating CheXpert F1 from 0.362 to 0.372. The model’s reasoning coherence was quantitatively validated using Kendall’s tau-b correlation, which measured alignment between intermediate reasoning paths and final conclusions. Scores of 0.479 (consistency) and 0.474 (completeness; both P < 0.05) indicate strong logical agreement.
2025XMedGPT sentence-level uncertainty estimation proposed non-standard sliceAUC0.764split: test · method=semantic entropy with test-time scaling · subset=200 samplesMulti-Modal Explainable Medical AI Assistant for Trustworthy Human-AI Collaboration
Source quote
L76: Having validated the effectiveness of our uncertainty estimation approach on medical VQA tasks, we extended it to the domain of medical report captioning for sentence-level uncertainty estimation, as illustrated in \Cref{fig:Uncertainty_method}. For each sentence generated in a medical report, our system generates multiple questions based on the sentence using a large language model. The consistency between the answers to these questions and the caption is assessed, with semantic entropy calculated to quantify uncertainty for each sentence. We evaluated the reliability of the uncertainty estimates on a subset (n = 200) of the MIMIC-CXR test dataset. As the number of questions increased from 1 to 5, the AUC improved from 0.676 to 0.764, reflecting a 13.02% enhancement. This substantial improvement demonstrates the effectiveness of combining semantic entropy with test-time scaling for estimating sentence-level uncertainty.
2025BadMLLM proposed non-standard sliceASR0.980fine-tuned · trigger=promotional phishing slogan · backbone=LLaVA-Med · target-disease=PneumoniaShadow-Activated Backdoor Attacks on Multimodal Large Language Models
Source quote
L483: 0.980
2025BadMLLM proposed non-standard sliceASR1.000fine-tuned · trigger=promotional phishing slogan · backbone=LLaVA-Med · target-disease=PneumothoraxShadow-Activated Backdoor Attacks on Multimodal Large Language Models
Source quote
L485: 1.000
2025CoD proposedHorizontal lesion location accuracy0.514split: test · attribute=horizontal-lesion-location · evaluator=AttriBertA Chain of Diagnosis Framework for Accurate and Explainable Radiology Report Generation
Source quote
L305: We compare our model with SOTA RRG methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, RGRG~\cite{TMK23}, R2GenGPT~\cite{WLW23b}, PromptMRG~\cite{JCL24}, and I3+C2FD~\cite{LTC24}. Moreover, we have added generalist foundation models for comparison, including Med-Flamingo~\cite{MHW23}, RadFM~\cite{WZZ23}, InternVL~\cite{CWW24}, LLaVA-Med~\cite{LWZ24}, and MedDr~\cite{HNW24}, which are trained to tackle various medical tasks rather than RRG alone. Table~\ref{tab:results_sota} shows the results on both IU X-Ray and MIMIC-CXR. First of all, we can see from the table that the proposed CoD obtains the best performance on most of the entries. To be specific, CoD obtains the best results on 11 out of 12 entries within CE metrics, demonstrating its superiority in generating clinically accurate reports. Notably, our method outperforms the other methods considerably in attribute accuracy, thanks to the effective guidance of QA prompts. For example, our method achieves 0.514 and 0.404 of horizontal lesion location accuracy on MIMIC and IU, which have gained 19.3% and 16.8% improvement respectively over the second best method PromptMRG. In terms of NLG metrcis, CoD obtains best results on four out of six entries, indicating the superior capability of LLMs in generating fluent and relevant texts. Interestingly, the performance of generalist foundation models are far behind that of specialists, where MedDr performs the best among generalists. This is understandable as generalists are supposed to deal with a number of tasks as well as out-of-domain data, which inevitably degrades their competitiveness on a specific task/data.
2025REVTAF (full model: LRE and FVTAF enabled) proposedAvg0.397split: testLearnable Retrieval Enhanced Visual-Text Alignment and Fusion for Radiology Report Generation
Source quote
L189: Ours │ 0.465 │ 0.318 │ 0.235 │ 0.182 │ 0.199 │ 0.336 │ 0.628 │ 0.613 │ 0.592 │ 0.397
2025CXRAgent framework proposedRaTEScore0.513split: test · subset=400 randomly selected casesCXRAgent: Director-Orchestrated Multi-Stage Reasoning for Chest X-Ray Interpretation
Source quote
L260: MIMIC-CXR. As demonstrated in Table~\ref{tab:report1}, our proposed CXRAgent framework achieves superior performance in chest X-ray report generation, attaining the highest RaTEScore of 0.513 among all evaluated models. This metric, which specifically measures the accuracy of clinical entity recognition, highlights our method's exceptional capability in identifying and describing medically relevant findings with precision. The RaTEScore performance represents a significant advancement over general-purpose multimodal models such as GPT-4o (0.429) and Qwen-VL-Max (0.415), demonstrating the effectiveness of our approach to report generation. In terms of overall report quality assessment using the LLMScore metric, our GPT-based implementation achieves a score of 2.77, ranking second only to LLaVA-Rad (2.99), which is specifically optimized for radiology report generation. This performance is particularly noteworthy given that LLaVA-Rad employs dedicated training strategies tailored specifically for this task. Compared to baseline models, our framework demonstrates substantial improvements, with relative enhancements of 34.5% over GPT-4o (2.06) and 23.1% over MedRAX with GPT backbone (2.25). These improvements underscore the effectiveness of our multi-stage reasoning framework in generating clinically coherent and comprehensive radiology reports. The consistent performance across both evaluation dimensions—entity-level recognition (RaTEScore) and overall quality (LLMScore)—validates the robustness of our approach. The integration of EDV ensures that generated reports maintain high factual accuracy, while the adaptive team collaboration mechanism enables comprehensive coverage of clinical findings. This balanced performance across different assessment criteria demonstrates the framework's capability to handle the complex requirements of clinical report generation, where both precise entity extraction and overall narrative quality are essential for practical utility.
2025UniMedVL proposedRaTE0.5138Report-generation evaluation; table reports NLG and clinical efficacy metricsUniMedVL: Unifying Medical Multimodal Understanding and Generation through Observation-Knowledge-Analysis
Source quote
L1137: UniMedVL (Ours) │ \checkmark │ 0.2193 │ 0.0235 │ 0.2843 │ 0.2727 │ 0.5138
2025AURAD-generated data augmentation proposeddisease classification accuracy gain+3.78%Cross-domain disease classification evaluation; training augmented with AURAD-generated…AURAD: Anatomy-Pathology Unified Radiology Synthesis with Progressive Representations
Source quote
L264: Cross-domain performance is evaluated on three external datasets: ChestX-ray14 and VinDr-CXR for lesion detection, and MIMIC-CXR for disease classification (Tables~\ref{tab:det_result} and~\ref{tab:cls_result}). Augmenting training with AURAD -generated samples improves performance, with gains of +5.02% mAP on ChestX-ray14, +1.40% on VinDr-CXR, and +3.78% classification accuracy on MIMIC-CXR. These results highlight the robustness of our approach and its ability to mitigate dataset-specific overfitting.
2025MediVLM proposedBLEU-40.059unsupervisedMediVLM: A Vision Language Model for Radiology Report Generation from Medical Images
Source quote
L486: 0.059
2025MIRA proposed non-standard sliceCIDEr0.299subset=1,000 samplesMIRA: A Novel Framework for Fusing Modalities in Medical RAG
Source quote
L316: MIRA outperforms all baselines, achieving the highest BLEU-1 (0.571), BLEU-4 (0.175), METEOR (0.292), ROUGE-L (0.3232), CIDEr (0.299), and SPICE (0.318) scores. Its strong performance, despite no exposure to MIMIC-CXR during pre-training, reflects robust generalization rather than overfitting.
2025MIRA proposed non-standard sliceSPICE0.318subset=1,000 samplesMIRA: A Novel Framework for Fusing Modalities in Medical RAG
Source quote
L316: MIRA outperforms all baselines, achieving the highest BLEU-1 (0.571), BLEU-4 (0.175), METEOR (0.292), ROUGE-L (0.3232), CIDEr (0.299), and SPICE (0.318) scores. Its strong performance, despite no exposure to MIMIC-CXR during pre-training, reflects robust generalization rather than overfitting.
2024D-KD (RadBERT-Roberta-4m-document, contrastive) proposed non-standard sliceAccuracy85.52%split: test · params=4m · subset=p11 high-confidence-filtered test documents · backbone=RadBERT-Roberta-4m-documentIntegrating ChatGPT into Secure Hospital Networks: A Case Study on Improving Radiology Report Analysis
Source quote
L176: \begin{tabular}[c]{@{}c@{}}RadBERT-Roberta\\-4m-document\\contrastive │ \begin{tabular}[c]{@{}c@{}}85.52\\(+ 0.35) │ \begin{tabular}[c]{@{}c@{}}0.858\\(+0.026) │ \begin{tabular}[c]{@{}c@{}}0.840\\(-0.012) │ \begin{tabular}[c]{@{}c@{}}0.901\\(+0.055)
2024FSE-1 proposedBL-1 (BLEU-1)0.397split: test · reference-report-truncation=M_gt=80Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report Generation
Source quote
L229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency.
2024FSE-1 proposedCX14 (CheXbert micro-F1, 14 categories)0.470split: test · reference-report-truncation=M_gt=80Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report Generation
Source quote
L229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency.
2024EVOKE (multi-view; Stage 1 fact-serialization alignment with MPC, G, and L; Stage 2 indication and bridge enabled) proposedF1 RadGraph (RG)0.276resolution=224×224MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report Generation
Source quote
L180: EVOKE │ M │ F │ \ding{51} │ \ding{51} │ \ding{51} │ \ding{51} (\ding{51}) │ 0.262 │ 0.147 │ 0.167 │ 0.311 │ 0.276 │ 0.557 │ 0.499
2024EVOKE (multi-view; Stage 1 fact-serialization alignment with MPC, G, and L; Stage 2 indication and bridge enabled) proposedBLEU-4 (B-4)0.147resolution=224×224MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report Generation
Source quote
L180: EVOKE │ M │ F │ \ding{51} │ \ding{51} │ \ding{51} │ \ding{51} (\ding{51}) │ 0.262 │ 0.147 │ 0.167 │ 0.311 │ 0.276 │ 0.557 │ 0.499
2024CLIP(SapBERT)+AHIVE proposedCE(11/5) micro-average F10.678split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impressionAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L499: 0.678
2024CLIP(SapBERT)+AHIVE proposedCE(11) micro-average F10.604split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impressionAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L498: 0.604
2024CLIP(SapBERT)+AHIVE proposedCE(13+NL) micro-average F10.685split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impressionAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L500: 0.685
2024MDAgents (Adaptive; GPT-4o-mini) proposedAccuracy56.0%split: test · 0-shotMDAgents: An Adaptive Collaboration of LLMs for Medical Decision-Making
Source quote
L525: \shortcolorbox{MDAgents (Ours)} │ 75.0 │ 89.0 │ 59.0 │ 67.0 │ 56.0