MIMIC-CXR

263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

68.772.676.580.32024M-FLAG: 69.5 (2023)DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained): 79.53 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 150 of 205 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026CLEAR (MedGemma, Blur) proposedAUPRC90.23%split: testVisually Irrelevant Hallucinations in Medical Vision-Language Models
Source quote
L37: CXR, CLEAR improves AUPRC from 85.10% to 90.23%. Its
2026IMT-CXR proposedBL-138.6split: testA unified multi-task framework enables interpretable chest radiograph analysis
Source quote
L688: Ours │ 38.6 │ 13.1 │ 16.7 │ 27.5 │ 42.8 │ 31.5 │ 33.1
2026CompDiff proposedFID64.3split: test · seeds=3 · training_steps=up to 30000CompDiff: Hierarchical Compositional Diffusion for Fair and Zero-Shot Intersectional Medical Image Generation
Source quote
L131: Table~\ref{tab:overall_and_equity} compares CompDiff against baselines across chest X-ray and fundus modalities. CompDiff achieves the best FID on both modalities (64.3 chest, 54.6 fundus). While FairDiffusion achieves slightly lower FID-RadImageNet on chest (6.2 vs 6.8), CompDiff outperforms on disease classification AUROC (0.82 vs 0.74), indicating better clinical feature alignment. MS-SSIM values remain in the acceptable range (0.25--0.75) for all models, confirming neither overfitting nor generation failure. Sex accuracy remains near-perfect across all methods. Slightly reduced race accuracy and increased age RMSE are expected trade-offs from HCN conditioning, offset by improved subgroup-level fairness below.
2026FINO proposedAUROC81.8split: test · params=2.7M label-supervised · subset=IID; 14 pathology labels · backbone=DINOv3 ViT-L/16Who Needs Labels? Adapting Vision Foundation Models With the Metadata You Already Have
Source quote
L201: \bf FINO (ours) │ 2.7M │ {\color{cyan}\Snow} │ {\bf 61.2} │ {\bf 53.1} │ \bf{52.9} │ {\bf 81.8}
2026Bayesian Pairwise Merging (BPM) proposed non-standard sliceMacro decided win rate against uniform merge (RS)91.7%split: test · feedback-budget=100The Missing Coefficients: Bayesian Pairwise Merging for Model Personalization
Source quote
L321: RS │ \mrbhldiff{91.7}{50}\,\mrbci{90.3, 93.1} │ \mrbhldiff{88.4}{50}\,\mrbci{86.2, 90.4} │ \mrbhldiff{77.1}{50}\,\mrbci{74.7, 79.3} │ \mrbhldiff{78.7}{50}\,\mrbci{76.6, 80.7} │ \mrbhldiff{64.3}{50}\,\mrbci{62.5, 66.1} │ \mrbhldiff{76.1}{50}\,\mrbci{74.4, 77.8}
2026Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposedAUPRC87.78%split: testCase-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive Supervision
Source quote
L226: S3: Case + Evidence + Claim │ 97.43 │ 87.78 │ 78.72 │ 92.03 │ 0.060
2026Evidence-only baseline (S2: Evidence + Claim; shared ModernBERT-large verifier) proposedAUPRC35.11%split: testCase-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive Supervision
Source quote
L225: S2: Evidence + Claim │ 82.63 │ 35.11 │ 62.79 │ 87.53 │ 0.255
2026Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposedAUROC97.43%split: testCase-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive Supervision
Source quote
L226: S3: Case + Evidence + Claim │ 97.43 │ 87.78 │ 78.72 │ 92.03 │ 0.060
2026Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposedAUROC55.62%split: testCase-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive Supervision
Source quote
L1297: AUROC │ 97.43 ± 0.27 [97--98] │ 97.24 ± 0.33 [97--98] │ 55.62 ± 1.50 [53--59]
2026Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposedAUPRC74.18%split: testCase-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive Supervision
Source quote
L1298: AUPRC │ 87.78 ± 1.56 [85--91] │ 74.18 ± 3.20 [68--80] │ 21.73 ± 1.54 [19--25]
2026AR-RRG proposedB-40.152split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedB-10.425split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedB-20.292split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedB-30.210split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedRG-L0.322split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026CheXOne-drafted reports proposedcases with reports judged comparable to or better than resident-written reports55\%split: test · study=radiologist reader study · sample-size=80 radiographs · radiologists=11A Reasoning-Enabled Vision-Language Foundation Model for Chest X-ray Interpretation
Source quote
L18: A clinical reader study demonstrates that CheXOne-drafted reports are comparable to or better than resident-written reports in 55% of cases, while effectively addressing clinical indications and enhancing both report writing and CXR interpretation efficiency.
2025GPT-4o, Thought Graph Traversal (TGT) proposedBLEU-49.84%split: test · backbone=GPT-4oSimple Radiology VLLM Test-time Scaling with Thought Graph Traversal
Source quote
L200: TGT │ 29.25 │ 15.81 │ 8.95 │ 9.84 │ 14.12 │ 26.50
2025HuatuoGPT-Vision, Thought Graph Traversal (TGT) proposedBLEU-411.34%split: test · backbone=HuatuoGPT-VisionSimple Radiology VLLM Test-time Scaling with Thought Graph Traversal
Source quote
L208: TGT │ 32.99 │ 18.89 │ 10.85 │ 11.34 │ 14.36 │ 27.06
2025DLDM (disentangled latent diffusion model) proposedEffectiveness Accuracy89.2%split: test · intervention=do(A=black)AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual Analysis
Source quote
L605: DLDM │ 89.2 │ 92.0 │ 93.7
2025Synthetic+Real mix model (maximal synthetic data) proposedAUROC0.770split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrainedImproving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic Data
Source quote
L135: The synthetic+real model with maximal data achieved an AUROC of 0.770 (CI: 0.762-0.778) for the multi-label classification task on the in-distribution MIMIC-CXR test set.
2025MedUnifier (w TIG) proposedBLEU-1 (BL-1)41.5split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MedUnifier (w TIG) proposedBLEU-4 (BL-4)12.9split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MedUnifier (w TIG) proposedMETEOR (MTR)22.7split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MedUnifier (w TIG) proposedROUGE-L (RG-L)34.0split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MVMAE proposedmacro-AUROC over 14 CheXpert labels0.75split: test · fine-tuned · view=frontal · labels=5,000Leveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L137: Frontal │ 0.75 │ 0.65
2025MVMAE proposedmacro-AUROC over 14 CheXpert labels0.73split: test · fine-tuned · view=lateral · labels=5,000Leveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L138: Lateral │ 0.73 │ 0.65
2025MVMAE proposedmacro-AUROC over 14 CheXpert labels0.75split: test · fine-tuned · view=frontal+lateral ensemble · fusion=late · labels=5,000Leveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L139: Ensemble │ 0.75 │ 0.69 \multirow{3}{*}{Contrastive}
2025SS-ACL proposedBLEU-40.144split: test · test-samples=3858Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report Generation
Source quote
L447: {\color[HTML]{C00000} 0.144}
2025SS-ACL proposedClinical efficacy macro F10.505split: test · categories=14 thoracic diseases · test-samples=3858 · clinical-labeler=CheXbertSelf-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report Generation
Source quote
L453: {\color[HTML]{C00000} 0.505}
2025DDaTR (SwinT-B) proposedF1_macro (Clinical Efficacy)0.441split: test · backbone=SwinT-B · averaging=macroDDaTR: Dynamic Difference-aware Temporal Residual Network for Longitudinal Radiology Report Generation
Source quote
L313: Ours │ 0.438 │ 0.465 │ 0.441 (+0.049) │ 0.113 │ 0.162 │ 0.272
2025DiffRGenNet proposedF10.483split: testDiffRGenNet: Difference-aware Medical Report Generation
Source quote
L286: 0.483
2025MedAlign proposedF195.25%split: test · params=7B · backbone=LLaVA-Med-1.5 7BMedAlign: A Synergistic Framework of Multimodal Preference Optimization and Federated Meta-Cognitive Reasoning
Source quote
L417: MedAlign │ 95.64 │ 96.47 │ 95.25 │ 94.36 │ 22.99 │ 27.89 │ 16.33 │ 2.29
2025ARRA (text-generation-only LLM initialization) proposedFID5.30split: test · subset=1,000 pairs · resolution=512×512Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation Alignment
Source quote
L309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576.
2025ARRA (text-generation-only LLM initialization) proposedCLIP-Score0.4532split: test · subset=1,000 pairs · backbone=CLIP · resolution=512×512Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation Alignment
Source quote
L309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576.
2025ARRA-Adapt (general image-generation pretrained LLM initialization) proposedFID4.15split: test · subset=1,000 pairs · resolution=512×512Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation Alignment
Source quote
L309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576.
2025ARRA-Adapt (general image-generation pretrained LLM initialization) proposedCLIP-Score0.4576split: test · subset=1,000 pairs · backbone=CLIP · resolution=512×512Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation Alignment
Source quote
L309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576.
2025MeDiM proposedFID16.60split: testDiscrete Diffusion Models with MLLMs for Unified Medical Multimodal Generation
Source quote
L34: 1) For medical image generation, MeDiM achieves state-of-the-art Frechet Inception Distances (FID) on the MIMIC-CXR~\citep{johnson2019mimic} and PathGen~\citep{sun2024pathgen} datasets, respectively (Tab.~\ref{tab_1} and Tab.~\ref{tab_2}; 16.60 FID and 24.19 FID), generating high-fidelity medical images across different modalities (Fig.~\ref{fig_qual}; robust and high visual quality).
2025MeDiM proposed non-standard sliceMETEOR (table label: MTR)0.265split: testDiscrete Diffusion Models with MLLMs for Unified Medical Multimodal Generation
Source quote
L275: MeDiM (Ours) │ MLLM │ 0.328 │ 0.185 │ 0.109 │ 0.265 │ 0.297 │ 0.185 │ 0.084 │ 0.037 │ 0.258 │ 0.226
2025MCA-RG (7B; listed as Ours) proposedExample-based F10.408split: test · params=7B · scores=CE · averaging=example-basedMCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report Generation
Source quote
L172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt]
2025MCA-RG (7B; listed as Ours) proposedMacro-based F10.335split: test · params=7B · scores=CE · averaging=macro-basedMCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report Generation
Source quote
L172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt]
2025ChexGen proposedFID (CLIP features)0.89split: test · backbone=CLIP · sample-size=3500 cases · feature-extractor=CLIPA Generative Foundation Model for Chest Radiography
Source quote
L76: We assessed fidelity by calculating the FID (lower is better) between synthetic and real CXRs, extracting features from a pretrained general-purpose model (CLIP~\cite{radford2021learning}) and a domain-specific chest radiograph classifier (XRV~\cite{Cohen2022xrv}). ChexGen achieved substantially better fidelity with lower FID scores compared to MINIM-CXR~\cite{wang2024self} and RoentGen~\cite{chambon2022roentgen} (CLIP: 0.89 vs. 9.63 and 4.42; XRV: 0.57 vs. 8.29 and 6.80) (\textbf{\cref{fig:figure2}a}, p < 0.001). These results demonstrate that ChexGen better captures the distribution of real-world chest radiographs.
2025ChexGen-balanced DenseNet121 model proposedWeighted F1-score for worst-performing gender group0.387split: test · model=DenseNet121 · subgroup=worst-performing gender group · training-data=ChexGen-balancedA Generative Foundation Model for Chest Radiography
Source quote
L160: In addition to detecting model bias, we explored whether synthetic data could be used to further mitigate the observed bias. Using ChexGen, we generated additional training samples for underrepresented demographic subgroups until their representation matched that of the majority groups. Consequently, the augmented training data led to substantial improvements in model fairness across all demographic dimensions. For instance, the F1-Scores increased significantly for the worst group (gender: 0.338 to 0.387, race: 0.321 to 0.394, age: 0.363 to 0.419), while performance gaps between best and worst groups narrowed considerably with a relative reduction of up to 60% (gender: 2.5% to 1.6%, race: 2.9% to 1.2%, age: 2.3% to 1.2%) (\textbf{\cref{fig:figure6}d}). These results highlight the potential of CheXGen for generating synthetic data to enhance model fairness by detecting and mitigating bias.
2025Domain-specific tokenizer (Specific) proposedR-L0.344split: test · vocabulary-size=9.1kSpecialised or Generic? Tokenization Choices for Radiology Language Models
Source quote
L167: Specific │ \ding{55} │ 9.1k │ 0.273 │ 0.364 │ 0.344 │ 0.514 │ 0.604 │ 0.270 │ 0.813
2025RadVLM+RL (GRPO) proposedBERTScore (B-S)59.2split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findingsRadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement Learning
Source quote
L117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86
2025RadVLM+RL (GRPO) proposedGREEN (GRN)32.7split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findingsRadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement Learning
Source quote
L117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86
2025RadVLM+RL (GRPO) proposedRadCliQ (RCQ)0.86split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findingsRadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement Learning
Source quote
L117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86
2025Weighted Avg (W-Avg; PRM scores) proposedF1-CheXbert0.3575split: test · subset=full-unbalanced · strategy=weighted-average · generator=MAIRA-2 · candidates=128 · temperature=1.0Process Reward Models for Sentence-Level Verification of LVLM Radiology Reports
Source quote
L536: Our results (Figures~\ref{fig:bon_weighted_all} and \ref{fig:bon_nonweighted_all}) show that weighted strategies generally outperform non-weighted ones. For instance, Weighted Avg (W-Avg) using PRM scores improves F1-CheXbert by +5.0 points (0.3575 vs 0.3077 for non-weighted AvgProb) at N=128. Similarly, W-Avg boosts BERTScore by +0.001 points (0.8594 vs 0.8584) under the same conditions. The choice of N also impacts performance, with larger N generally leads to better results.
2025HTSC-CIF proposedMETEOR0.177split: testMedical Report Generation: A Hierarchical Task Structure-Based Cross-Modal Causal Intervention Framework
Source quote
L230: Ours │ 0.413 │ 0.264 │ 0.193 │ 0.139 │ 0.177 │ 0.305 │ 0.386
2025HTSC-CIF proposedROUGE-L0.305split: testMedical Report Generation: A Hierarchical Task Structure-Based Cross-Modal Causal Intervention Framework
Source quote
L230: Ours │ 0.413 │ 0.264 │ 0.193 │ 0.139 │ 0.177 │ 0.305 │ 0.386
2025KIA proposedBLEU-40.138split: testKIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report Generation
Source quote
L535: Specifically, our KIA achieves 0.188 and 0.138
2025KIA proposedCIDEr0.316split: testKIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report Generation
Source quote
L538: Notably, our CIDEr scores of 0.641 and 0.316 on two datasets achieve considerable improvements of 9% and 6%, showing that reports generated by KIA are highly relevant to the image content and accurately reflect important information. This illustrates that the multitask implicit alignment we designed can effectively enhance the understanding of images and reports.
2025KIA proposed non-standard sliceF1-Score0.461split: test · clinical-labels=14 CheXpert abnormality categoriesKIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report Generation
Source quote
L477: 0.461
2025XMedGPT with the clinical reasoning framework proposedKendall’s tau-b (consistency)0.479split: test · fine-tuned · training=SFT and DPO · annotation=Chest-Imagenome-derived regionsMulti-Modal Explainable Medical AI Assistant for Trustworthy Human-AI Collaboration
Source quote
L82: Training on the MIMIC-CXR dataset involved supervised fine-tuning (SFT) with 10,000 samples for long chain-of-thought reasoning, followed by reinforcement learning via Direct Preference Optimization (DPO) on 8,201 high/low-scoring report pairs. Evaluation on a test set annotated with Chest-Imagenome-derived regions revealed a 6.05% average improvement across clinical metrics (CheXpert F1, Radgraph F1, CheXpert Similarity) compared to non-reasoning baselines. DPO further refined report quality, elevating CheXpert F1 from 0.362 to 0.372. The model’s reasoning coherence was quantitatively validated using Kendall’s tau-b correlation, which measured alignment between intermediate reasoning paths and final conclusions. Scores of 0.479 (consistency) and 0.474 (completeness; both P < 0.05) indicate strong logical agreement.
2025XMedGPT sentence-level uncertainty estimation proposed non-standard sliceAUC0.764split: test · method=semantic entropy with test-time scaling · subset=200 samplesMulti-Modal Explainable Medical AI Assistant for Trustworthy Human-AI Collaboration
Source quote
L76: Having validated the effectiveness of our uncertainty estimation approach on medical VQA tasks, we extended it to the domain of medical report captioning for sentence-level uncertainty estimation, as illustrated in \Cref{fig:Uncertainty_method}. For each sentence generated in a medical report, our system generates multiple questions based on the sentence using a large language model. The consistency between the answers to these questions and the caption is assessed, with semantic entropy calculated to quantify uncertainty for each sentence. We evaluated the reliability of the uncertainty estimates on a subset (n = 200) of the MIMIC-CXR test dataset. As the number of questions increased from 1 to 5, the AUC improved from 0.676 to 0.764, reflecting a 13.02% enhancement. This substantial improvement demonstrates the effectiveness of combining semantic entropy with test-time scaling for estimating sentence-level uncertainty.
2025CoD proposedHorizontal lesion location accuracy0.514split: test · attribute=horizontal-lesion-location · evaluator=AttriBertA Chain of Diagnosis Framework for Accurate and Explainable Radiology Report Generation
Source quote
L305: We compare our model with SOTA RRG methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, RGRG~\cite{TMK23}, R2GenGPT~\cite{WLW23b}, PromptMRG~\cite{JCL24}, and I3+C2FD~\cite{LTC24}. Moreover, we have added generalist foundation models for comparison, including Med-Flamingo~\cite{MHW23}, RadFM~\cite{WZZ23}, InternVL~\cite{CWW24}, LLaVA-Med~\cite{LWZ24}, and MedDr~\cite{HNW24}, which are trained to tackle various medical tasks rather than RRG alone. Table~\ref{tab:results_sota} shows the results on both IU X-Ray and MIMIC-CXR. First of all, we can see from the table that the proposed CoD obtains the best performance on most of the entries. To be specific, CoD obtains the best results on 11 out of 12 entries within CE metrics, demonstrating its superiority in generating clinically accurate reports. Notably, our method outperforms the other methods considerably in attribute accuracy, thanks to the effective guidance of QA prompts. For example, our method achieves 0.514 and 0.404 of horizontal lesion location accuracy on MIMIC and IU, which have gained 19.3% and 16.8% improvement respectively over the second best method PromptMRG. In terms of NLG metrcis, CoD obtains best results on four out of six entries, indicating the superior capability of LLMs in generating fluent and relevant texts. Interestingly, the performance of generalist foundation models are far behind that of specialists, where MedDr performs the best among generalists. This is understandable as generalists are supposed to deal with a number of tasks as well as out-of-domain data, which inevitably degrades their competitiveness on a specific task/data.
2025REVTAF (full model: LRE and FVTAF enabled) proposedAvg0.397split: testLearnable Retrieval Enhanced Visual-Text Alignment and Fusion for Radiology Report Generation
Source quote
L189: Ours │ 0.465 │ 0.318 │ 0.235 │ 0.182 │ 0.199 │ 0.336 │ 0.628 │ 0.613 │ 0.592 │ 0.397
2025CXRAgent framework proposedRaTEScore0.513split: test · subset=400 randomly selected casesCXRAgent: Director-Orchestrated Multi-Stage Reasoning for Chest X-Ray Interpretation
Source quote
L260: MIMIC-CXR. As demonstrated in Table~\ref{tab:report1}, our proposed CXRAgent framework achieves superior performance in chest X-ray report generation, attaining the highest RaTEScore of 0.513 among all evaluated models. This metric, which specifically measures the accuracy of clinical entity recognition, highlights our method's exceptional capability in identifying and describing medically relevant findings with precision. The RaTEScore performance represents a significant advancement over general-purpose multimodal models such as GPT-4o (0.429) and Qwen-VL-Max (0.415), demonstrating the effectiveness of our approach to report generation. In terms of overall report quality assessment using the LLMScore metric, our GPT-based implementation achieves a score of 2.77, ranking second only to LLaVA-Rad (2.99), which is specifically optimized for radiology report generation. This performance is particularly noteworthy given that LLaVA-Rad employs dedicated training strategies tailored specifically for this task. Compared to baseline models, our framework demonstrates substantial improvements, with relative enhancements of 34.5% over GPT-4o (2.06) and 23.1% over MedRAX with GPT backbone (2.25). These improvements underscore the effectiveness of our multi-stage reasoning framework in generating clinically coherent and comprehensive radiology reports. The consistent performance across both evaluation dimensions—entity-level recognition (RaTEScore) and overall quality (LLMScore)—validates the robustness of our approach. The integration of EDV ensures that generated reports maintain high factual accuracy, while the adaptive team collaboration mechanism enables comprehensive coverage of clinical findings. This balanced performance across different assessment criteria demonstrates the framework's capability to handle the complex requirements of clinical report generation, where both precise entity extraction and overall narrative quality are essential for practical utility.
2024D-KD (RadBERT-Roberta-4m-document, contrastive) proposed non-standard sliceAccuracy85.52%split: test · params=4m · subset=p11 high-confidence-filtered test documents · backbone=RadBERT-Roberta-4m-documentIntegrating ChatGPT into Secure Hospital Networks: A Case Study on Improving Radiology Report Analysis
Source quote
L176: \begin{tabular}[c]{@{}c@{}}RadBERT-Roberta\\-4m-document\\contrastive │ \begin{tabular}[c]{@{}c@{}}85.52\\(+ 0.35) │ \begin{tabular}[c]{@{}c@{}}0.858\\(+0.026) │ \begin{tabular}[c]{@{}c@{}}0.840\\(-0.012) │ \begin{tabular}[c]{@{}c@{}}0.901\\(+0.055)
2024FSE-1 proposedBL-1 (BLEU-1)0.397split: test · reference-report-truncation=M_gt=80Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report Generation
Source quote
L229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency.
2024FSE-1 proposedCX14 (CheXbert micro-F1, 14 categories)0.470split: test · reference-report-truncation=M_gt=80Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report Generation
Source quote
L229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency.
2024CLIP(SapBERT)+AHIVE proposedCE(11/5) micro-average F10.678split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impressionAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L499: 0.678
2024CLIP(SapBERT)+AHIVE proposedCE(11) micro-average F10.604split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impressionAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L498: 0.604
2024CLIP(SapBERT)+AHIVE proposedCE(13+NL) micro-average F10.685split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impressionAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L500: 0.685
2024MDAgents (Adaptive; GPT-4o-mini) proposedAccuracy56.0%split: test · 0-shotMDAgents: An Adaptive Collaboration of LLMs for Medical Decision-Making
Source quote
L525: \shortcolorbox{MDAgents (Ours)} │ 75.0 │ 89.0 │ 59.0 │ 67.0 │ 56.0
2024FactMM-RAG proposedF1CheXbert0.605split: test · retrieval-setting=multimodalFact-Aware Multimodal Retrieval Augmentation for Accurate Medical Radiology Report Generation
Source quote
L269: FactMM-RAG │ 0.605 │ 0.249 │ 0.297 │ 0.547 │ 0.491 │ 0.174 │ 0.237 │ 0.467
2024FactMM-RAG proposedF1RadGraph0.249split: test · retrieval-setting=multimodalFact-Aware Multimodal Retrieval Augmentation for Accurate Medical Radiology Report Generation
Source quote
L269: FactMM-RAG │ 0.605 │ 0.249 │ 0.297 │ 0.547 │ 0.491 │ 0.174 │ 0.237 │ 0.467
2024FITA proposedBLEU-10.411split: testFITA: Fine-grained Image-Text Aligner for Radiology Report Generation
Source quote
L107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326
2024FITA proposedMETEOR0.172split: testFITA: Fine-grained Image-Text Aligner for Radiology Report Generation
Source quote
L107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326
2024FITA proposedROUGE-L0.295split: testFITA: Fine-grained Image-Text Aligner for Radiology Report Generation
Source quote
L107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326
2024SGRRG proposedBLEU-10.434split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024SGRRG proposedBLEU-40.149split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024SGRRG proposedMETEOR0.173split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024SGRRG proposed non-standard sliceMacro-average precision (clinical efficacy)0.440split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024SGRRG proposed non-standard sliceMacro-average recall (clinical efficacy)0.323split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024SGRRG proposed non-standard sliceMacro-average F1 (clinical efficacy)0.332split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024DiCoM proposedAUPR.948split: test · linear-probeDiCoM - Diverse Concept Modeling towards Enhancing Generalizability in Chest X-Ray Studies
Source quote
L214: DiCoM (ours) │ .865 │ .969 │ \multicolumn{1}{c|}{.852} │ .861 │ .987 │ .930 │ .843 │ {\ul .948} │ \multicolumn{1}{c|}{{\ul .802}} │ .840 │ .947 │ .807
2024DiCoM proposedAUPR.947split: test · fine-tunedDiCoM - Diverse Concept Modeling towards Enhancing Generalizability in Chest X-Ray Studies
Source quote
L214: DiCoM (ours) │ .865 │ .969 │ \multicolumn{1}{c|}{.852} │ .861 │ .987 │ .930 │ .843 │ {\ul .948} │ \multicolumn{1}{c|}{{\ul .802}} │ .840 │ .947 │ .807
2024MedRAT proposedCE Recall0.265split: test · paired-data=0%MedRAT: Unpaired Medical Report Generation via Auxiliary Tasks
Source quote
L340: MedRAT {(Ours)} │ 0.285 │ 0.265 │ 0.227
2024MedRAT proposedB-10.365split: test · paired-data=0%MedRAT: Unpaired Medical Report Generation via Auxiliary Tasks
Source quote
L321: MedRAT │ 0.365 │ 0.086 │ 0.132 │ 0.251 │ 0.138 │ 0.398 │ 0.455 │ 0.129 │ 0.171 │ 0.349 │ 0.204 │ 0.427
2024ChEX (VinDr-CXR and MIMIC-CXR training) proposedEx-F1-1458.76split: test · 0-shotChEX: Interactive Localization and Region Description in Chest X-Rays
Source quote
L636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}}
2024ChEX (VinDr-CXR and MIMIC-CXR training) proposedMic-F1-5+61.03split: test · 0-shotChEX: Interactive Localization and Region Description in Chest X-Rays
Source quote
L636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}}
2024ChEX (VinDr-CXR and MIMIC-CXR training) proposedMac-F1-5+55.85split: test · 0-shotChEX: Interactive Localization and Region Description in Chest X-Rays
Source quote
L636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}}
2024XReal proposedAvg. Radiologist Score — Anatomy4.167split: test · evaluation=radiologist-rating · rating-dimension=anatomyXReal: Realistic Anatomy and Pathology-Aware X-ray Generation via Controllable Diffusion Model
Source quote
L193: To solidify our assessment of the generated X-rays' clinical realism, two expert radiologists reviewed the images in a blind review setting. As shown in Table \ref{tab:results}, XReal outperformed other methods by a large margin with scores of 4.167 and 4.130 for anatomy and pathology, respectively, while surpassing real images in both anatomy (+0.536) and pathology realism (+0.569) evaluation. This improvement, particularly over real images, can be attributed to a number of factors, including XReal's ability to accurately generate all anatomical structures based on the provided anatomical mask (m_a), making both the anatomy and pathology clearer. Additionally, since the anatomical mask was obtained using a segmentation model, XReal can potentially avoid including artifacts that might be present in the real images but are not captured in the mask. This can lead to clearer anatomy and more evident pathology manifestations. However, it would be important to investigate incorporating X-ray artifacts in the future.
2024XReal proposedAvg. Radiologist Score — Pathology4.130split: test · evaluation=radiologist-rating · rating-dimension=pathologyXReal: Realistic Anatomy and Pathology-Aware X-ray Generation via Controllable Diffusion Model
Source quote
L193: To solidify our assessment of the generated X-rays' clinical realism, two expert radiologists reviewed the images in a blind review setting. As shown in Table \ref{tab:results}, XReal outperformed other methods by a large margin with scores of 4.167 and 4.130 for anatomy and pathology, respectively, while surpassing real images in both anatomy (+0.536) and pathology realism (+0.569) evaluation. This improvement, particularly over real images, can be attributed to a number of factors, including XReal's ability to accurately generate all anatomical structures based on the provided anatomical mask (m_a), making both the anatomy and pathology clearer. Additionally, since the anatomical mask was obtained using a segmentation model, XReal can potentially avoid including artifacts that might be present in the real images but are not captured in the mask. This can lead to clearer anatomy and more evident pathology manifestations. However, it would be important to investigate incorporating X-ray artifacts in the future.
2024IVGN proposedBL-20.236split: testIntensive Vision-guided Network for Radiology Report Generation
Source quote
L293: IVGN │ 0.377 │ 0.236 │ 0.158 │ 0.112 │ 0.144 │ 0.280 │ 0.415 │ 0.442 │ 0.398
2024IVGN proposedF1-score (CE)0.398split: testIntensive Vision-guided Network for Radiology Report Generation
Source quote
L293: IVGN │ 0.377 │ 0.236 │ 0.158 │ 0.112 │ 0.144 │ 0.280 │ 0.415 │ 0.442 │ 0.398
2024BiCAL CheSS proposed non-standard sliceRecall0.274split: test · active-learning · runs=3 · encoder=CheSS · queried-labels=1000 · training-subset=stratified 10% · evaluation-labels=CheXpertBiCAL: Bi-directional Contrastive Active Learning for Clinical Report Generation
Source quote
L208: 0.274
2024BiCAL CheSS proposed non-standard sliceF-1 Score0.219split: test · active-learning · runs=3 · encoder=CheSS · queried-labels=1000 · training-subset=stratified 10% · evaluation-labels=CheXpertBiCAL: Bi-directional Contrastive Active Learning for Clinical Report Generation
Source quote
L209: 0.219
2024Hard-CFT (Sex CFs) proposedAUC75.4%split: test · counterfactuals=sexMitigating Attribute Amplification in Counterfactual Image Generation
Source quote
L111: Hard-CFT │ \unint{75.4 {(\downarrow 18.4)}} │ \interv{79.6 {(\downarrow 20.0)}} │ \unint{89.8 {(\downarrow 4.4)}}
2024Soft-CFT (Sex CFs) proposedAUC92.4%split: test · counterfactuals=sexMitigating Attribute Amplification in Counterfactual Image Generation
Source quote
L112: Soft-CFT │ \unint{92.4 {(\downarrow 1.4)}} │ \interv{90.0 {(\downarrow 9.6)}} │ \unint{94.0 {(\downarrow 0.2)}}
2024Hard-CFT (Sex CFs) proposedAUC79.6%split: test · counterfactuals=sexMitigating Attribute Amplification in Counterfactual Image Generation
Source quote
L111: Hard-CFT │ \unint{75.4 {(\downarrow 18.4)}} │ \interv{79.6 {(\downarrow 20.0)}} │ \unint{89.8 {(\downarrow 4.4)}}
2024Soft-CFT (Sex CFs) proposedAUC90.0%split: test · counterfactuals=sexMitigating Attribute Amplification in Counterfactual Image Generation
Source quote
L112: Soft-CFT │ \unint{92.4 {(\downarrow 1.4)}} │ \interv{90.0 {(\downarrow 9.6)}} │ \unint{94.0 {(\downarrow 0.2)}}
2024MiniGPT-4 (FT)+I3+C2FD (INTER.) proposedBL-10.364split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediateBootstrapping Large Language Models for Radiology Report Generation
Source quote
L750: 0.364
2024MiniGPT-4 (FT)+I3+C2FD (FINAL) proposedBL-10.402split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=finalBootstrapping Large Language Models for Radiology Report Generation
Source quote
L757: 0.402
2024MiniGPT-4 (FT)+I3+C2FD (INTER.) proposedBL-40.093split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediateBootstrapping Large Language Models for Radiology Report Generation
Source quote
L753: 0.093
2024MiniGPT-4 (FT)+I3+C2FD (FINAL) proposedBL-40.128split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=finalBootstrapping Large Language Models for Radiology Report Generation
Source quote
L760: 0.128
2024MiniGPT-4 (FT)+I3+C2FD (INTER.) proposedRG-L0.261split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediateBootstrapping Large Language Models for Radiology Report Generation
Source quote
L755: 0.261
2024MiniGPT-4 (FT)+I3+C2FD (FINAL) proposedRG-L0.291split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=finalBootstrapping Large Language Models for Radiology Report Generation
Source quote
L762: 0.291
2024Fair Diagnosis (ResNet50) proposedACC84.67%split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=genderFair Diagnosis: Leveraging Causal Modeling to Mitigate Medical Bias
Source quote
L278: Resnet50 │ 84.67 │ 62.46 │ 1.78 │ 2.39 │ 1.19
2024Fair Diagnosis (ResNet50) proposed non-standard sliceADF (column label: ADF-e-3)1.19split: test · η=0.2 · backbone=ResNet50 · metric_scale=e-3 · train_test_split=90/10 · sensitive_attribute=genderFair Diagnosis: Leveraging Causal Modeling to Mitigate Medical Bias
Source quote
L278: Resnet50 │ 84.67 │ 62.46 │ 1.78 │ 2.39 │ 1.19
2024GPT4V + FactCheXcker (updated report) proposedMAE1.15 cmsplit: test · model=GPT4V · report=FactCheXcker-updatedFactCheXcker: Mitigating Measurement Hallucinations in Chest X-ray Report Generation Models
Source quote
L611: GPT4V │ 0.58 │ 0.22 │ 0.32 │ 0.60 │ 1.15 │ 3.08 │ 0.85 │ 0.74 │ 0.79 │ 0.65
2024CheXagent + FactCheXcker (updated report) proposedMAE1.20 cmsplit: test · model=CheXagent · report=FactCheXcker-updatedFactCheXcker: Mitigating Measurement Hallucinations in Chest X-ray Report Generation Models
Source quote
L613: CheXagent │ 0.76 │ 0.36 │ 0.49 │ 0.68 │ 1.20 │ 3.13 │ 0.81 │ 0.88 │ 0.84 │ 0.64
2024Cvt2distilgpt2 + FactCheXcker (updated report) proposedMAE1.35 cmsplit: test · model=Cvt2distilgpt2 · report=FactCheXcker-updatedFactCheXcker: Mitigating Measurement Hallucinations in Chest X-ray Report Generation Models
Source quote
L615: Cvt2distilgpt2 │ 0.72 │ 0.53 │ 0.61 │ 0.75 │ 1.35 │ 4.87 │ 0.70 │ 0.81 │ 0.75 │ 0.63
2024MedImageInsight proposedCheXbert Micro-avg F1-1453.6split: test · params=0.4BMedImageInsight: An Open-Source Embedding Model for General Domain Medical Imaging
Source quote
L203: MedImageInsight\xspace \tnote{a} │ 53.6 │ 57.2 │ 37.0 │ 48.3 │ 53.3 │ 58.6 │ 40.7 │ 51.7 │ 25.5 │ 28.8 │ 37.0 │ 15.2 │ 31.6
2024MMVM VAE (lateral representation zL) proposedAUROC78.7%split: test · evaluation=binary random forest · representation=lateral unimodal latent zLUnity by Diversity: Improved Representation Learning for Multimodal VAEs
Source quote
L294: PoE VAE’s frontal representations zF (MMVM zL: 78.7%, PoE zF : 78.5%), even though the lateral modality seems generally less informative (supervised xL: 79.0%, xF : 81.7%) for this task. The same observation can be made for other labels (see detailed results and discussion in Appendix B.7.3).
2024Memory Alignment Network (MA; proposed model) proposedBLEU-10.396split: testAutomatic Radiology Reports Generation via Memory Alignment Network
Source quote
L254: 0.396
2024M4CXR proposed non-standard slicemF1-14 (CheXbert)60.6split: test · subset=frontal images; 2,461 imagesM4CXR: Exploring Multitask Potentials of Multimodal Large Language Models for Chest X-Ray Interpretation
Source quote
L326: 60.6 │ 61.8 │ 40.0 │ 49.5 │ 53.6 │ 21.8 │ 33.9 │ 10.3 │ 28.5 │ 2,461
2024RayDINO proposedRadGraph F123.9split: testAdvancing human-centric AI for robust X-ray analysis through holistic self-supervised learning
Source quote
L278: RayDINO │ 13.8\ci{13.4}{14.2} │ 30.3\ci{29.7}{30.8} │ 23.9\ci{23.3}{24.6} │ 44.8\ci{44.0}{45.6} │ 3.07\ci{3.04}{3.11} │ 36.1\ci{34.4}{37.6} │ 54.8\ci{53.5}{56.0}
2024RayDINO proposedCheXbert score44.8split: testAdvancing human-centric AI for robust X-ray analysis through holistic self-supervised learning
Source quote
L278: RayDINO │ 13.8\ci{13.4}{14.2} │ 30.3\ci{29.7}{30.8} │ 23.9\ci{23.3}{24.6} │ 44.8\ci{44.0}{45.6} │ 3.07\ci{3.04}{3.11} │ 36.1\ci{34.4}{37.6} │ 54.8\ci{53.5}{56.0}
2024RayDINO proposedRadCliQ3.07split: testAdvancing human-centric AI for robust X-ray analysis through holistic self-supervised learning
Source quote
L278: RayDINO │ 13.8\ci{13.4}{14.2} │ 30.3\ci{29.7}{30.8} │ 23.9\ci{23.3}{24.6} │ 44.8\ci{44.0}{45.6} │ 3.07\ci{3.04}{3.11} │ 36.1\ci{34.4}{37.6} │ 54.8\ci{53.5}{56.0}
2024DAug (Full; DAug feature augmentation, Hybrid Contrastive criterion) proposedmAP@K, wAvg.799split: test · K=5 · backbone=CLIP ViT-Base/32 · direction=report-to-imageDAug: Diffusion-based Channel Augmentation for Radiology Image Retrieval and Classification
Source quote
L146: DAug (Full) │ DAug │ Hybrid Contrastive │ .77 │ .86 │ .83 │ .89 │ .64 │ .79 │ .80 │ .71 │ .81 │ .64 │ .79 │ .66 │ .76 │ .79 │ .767 │ .799
2024DAug (Full; DAug feature augmentation, Hybrid Contrastive criterion) proposedmAP@K, wAvg.771split: test · K=5 · backbone=CLIP ViT-Base/32 · direction=image-to-imageDAug: Diffusion-based Channel Augmentation for Radiology Image Retrieval and Classification
Source quote
L151: DAug (Full) │ DAug │ Hybrid Contrastive │ .72 │ .86 │ .83 │ .88 │ .53 │ .78 │ .79 │ .65 │ .81 │ .47 │ .77 │ .59 │ .69 │ .74 │ .721 │ .771
2024Generalized orthogonalization (C^h) proposedEstimated influence coefficient of age on predictions-0.011split: test · embedding=CXR foundation-model embeddings · dimensions=111 (SVD-reduced)Generalizing Orthogonalization for Models with Non-Linearities
Source quote
L44: Generalized orthogonalization \mathcal{C}^h │ 0.001 (0.994)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.011 (0.689)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.001 (0.753)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.000 (0.904)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}}
2024Generalized orthogonalization (C^h) proposedEstimated influence coefficient of Race (Black) on predictions-0.001split: test · embedding=CXR foundation-model embeddings · dimensions=111 (SVD-reduced)Generalizing Orthogonalization for Models with Non-Linearities
Source quote
L44: Generalized orthogonalization \mathcal{C}^h │ 0.001 (0.994)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.011 (0.689)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.001 (0.753)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.000 (0.904)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}}
2024GenX+AC (t=0)_1 proposedF1 score54.3split: test · backbone=ResNet-18 · auditing-component=AC · confidence-threshold=0Quality Control for Radiology Report Generation Models via Auxiliary Auditing Components
Source quote
L192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3
2024GenX+AC (t=0.8)_1 proposedF1 score58.4split: test · backbone=ResNet-18 · auditing-component=AC · confidence-threshold=0.8Quality Control for Radiology Report Generation Models via Auxiliary Auditing Components
Source quote
L192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3
2023BiomedJourney proposedMean AUROC (pathology classifier)80.54split: testBiomedJourney: Counterfactual Biomedical Image Generation by Instruction-Learning from Multimodal Patient Journeys
Source quote
L273: BiomedJourney\xspace{} (Ours) │ 72.08 │ 73.76 │ 88.64 │ 88.11 │ 80.12 │ 80.54 │ {10.9}
2023Classifier trained on D_distill proposedf-\theta (class) AUC0.810split: test · subset=40,000 training images · backbone=DenseNet-121 · test_size=3,101 imagesPrivacy Distillation: Reducing Re-identification Risk of Multimodal Diffusion Models
Source quote
L203: D-distill │ 1.34 % │ 0.810 │ 0.611-0.272
2023METransformer proposedCIDEr0.362split: testMETransformer: Radiology Report Generation by Transformer with Multiple Learnable Expert Tokens
Source quote
L158: Ours(METransformer) │ 0.386 │ 0.250 │ 0.169 │ 0.124 │ 0.291 │ 0.152 │ 0.362
2023XrayGPT (+ RadVicuna; row 4) proposedR-10.3213split: testXrayGPT: Chest Radiographs Summarization using Large Medical Vision-Language Models
Source quote
L115: + RadVicuna │ 0.3213 │ 0.0912 │ 0.1997
2023XrayGPT (+ RadVicuna; row 4) proposedR-20.0912split: testXrayGPT: Chest Radiographs Summarization using Large Medical Vision-Language Models
Source quote
L115: + RadVicuna │ 0.3213 │ 0.0912 │ 0.1997
2023XrayGPT (+ RadVicuna; row 4) proposedR-L0.1997split: testXrayGPT: Chest Radiographs Summarization using Large Medical Vision-Language Models
Source quote
L115: + RadVicuna │ 0.3213 │ 0.0912 │ 0.1997
2023DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposedAUC79.53%split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023Proposed method (OURS; RadBloomz fine-tuned with detected-abnormality prompts) proposedROUGE-L0.373split: test · fine-tuned · prompt=detected abnormalities and probabilities · generation-length=128 tokensGeneration of Radiology Findings in Chest X-Ray by Leveraging Collaborative Knowledge
Source quote
L147: OURS │ 0.373
2023CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposedBLEU425.58split: test · evaluation=RadSum23 public testKU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report Summarization
Source quote
L148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96
2023CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposedROUGE-L47.75split: test · evaluation=RadSum23 public testKU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report Summarization
Source quote
L148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96
2023CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposedBertscore64.80split: test · evaluation=RadSum23 public testKU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report Summarization
Source quote
L148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96
2023CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposedF1-cheXbert76.29split: test · evaluation=RadSum23 public testKU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report Summarization
Source quote
L148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96
2023CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposedF1-Radgraph50.96split: test · evaluation=RadSum23 public testKU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report Summarization
Source quote
L148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96
2023ELIXR proposedNDCG@50.76split: test · cutoff=5 · queries=19ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L25: AUCs of 0.893 and 0.898 across five findings (atelectasis, cardiomegaly, consolidation, pleural effusion, and pulmonary edema) for 1% (~2,200 images) and 10% (~22,000 images) training data), and semantic search (0.76 normalized discounted cumulative gain (NDCG) across nineteen queries, including perfect retrieval on twelve of them). Compared to existing data-efficient methods including supervised contrastive learning (SupCon), ELIXR required two orders of magnitude less data to reach similar performance. ELIXR also showed promise on CXR vision-language tasks, demonstrating overall accuracies of 58.7% and 62.5% on visual question answering and report quality assurance tasks, respectively. These results suggest that ELIXR is a robust and versatile approach to CXR AI.
2023ELIXR-B proposedAccuracy62.5%split: test · section=impressionELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L557: On more challenging text-generation tasks, ELIXR-B demonstrated overall accuracies of 58.7% and 54.8% on two visual question answering (VQA) datasets, VQA-RAD (CXR-only questions) (Table 5) and MIMIC-CXR test (Table 6), as well as 62.5% on report quality assurance (QA) on
2023PromptMRG proposedF1 score (clinical efficacy)0.476split: test · evaluation=CheXbert 14-disease-label clinical efficacyPromptMRG: Diagnosis-Driven Prompts for Medical Report Generation
Source quote
L190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details.
2023C^2M-DoT proposedBLEU-10.4842split: testC^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer network
Source quote
L275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850
2023C^2M-DoT proposedROUGE-L0.3850split: testC^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer network
Source quote
L275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850
2023Latent Diffusion Models proposedFID8.8325split: test · resolution=512×512Generative AI for Medical Imaging: extending the MONAI Framework
Source quote
L59: MIMIC-CXR │ 2D Chest X-ray │ 512 × 512 │ 8.8325 │ 0.4276 │ 0.9834
2023Pragmatic LLaMA proposedPos F10.307split: test · fine-tuned · epochs=3 · section=impression · training-examples=18264Pragmatic Radiology Report Generation
Source quote
L383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158
2023Pragmatic Retrieval proposedNeg F1-50.156split: test · section=impression · metric-subset=five most frequent negative labelsPragmatic Radiology Report Generation
Source quote
L382: Pragmatic Retrieval │ 0.293 │ 0.403 │ 0.103 │ 0.072 │ -0.103 │ 0.078 │ -0.084 │ \bf 0.077 │ \bf 0.156 │ 0.445
2023Pragmatic LLaMA proposedNeg F1-50.127split: test · fine-tuned · epochs=3 · section=impression · metric-subset=five most frequent negative labels · training-examples=18264Pragmatic Radiology Report Generation
Source quote
L383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158
2023KiUT proposedBLEU-10.393split: test · input-images=single-imageKiUT: Knowledge-injected U-Transformer for Radiology Report Generation
Source quote
L229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321
2023KiUT proposedF10.321split: test · input-images=single-image · label-source=CheXpertKiUT: Knowledge-injected U-Transformer for Radiology Report Generation
Source quote
L229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321
2023LA-SSL proposedPrecision (old subgroup)40.00%split: test · subgroup=older than 90Making Self-supervised Learning Robust to Spurious Correlation via Learning-speed Aware Sampling
Source quote
L339: LA-SSL │ 32.43 │ 16.07 │ 83.47 │ 74.89 │ 63.65 │ 40.00 │ 73.42 │ 34.83
2023Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposedBLEU-3 (BL-3)0.162split: testEnhanced Knowledge Injection for Radiology Report Generation
Source quote
L171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217
2023Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposedBLEU-4 (BL-4)0.119split: testEnhanced Knowledge Injection for Radiology Report Generation
Source quote
L171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217
2023Proposed longitudinal model with sentence-anatomy dropout proposedBL-40.246split: test · report_scope=full · prior_cxr_input=enabled · sentence_anatomy_dropout=enabledControllable Chest X-Ray Report Generation from Longitudinal Representations
Source quote
L360: 0.246
2023Proposed longitudinal model with sentence-anatomy dropout proposedRG-L0.423split: test · report_scope=full · prior_cxr_input=enabled · sentence_anatomy_dropout=enabledControllable Chest X-Ray Report Generation from Longitudinal Representations
Source quote
L362: 0.423
2023Proposed longitudinal model with sentence-anatomy dropout proposedF1 (CE)0.553split: test · report_scope=full · prior_cxr_input=enabled · sentence_anatomy_dropout=enabledControllable Chest X-Ray Report Generation from Longitudinal Representations
Source quote
L363: 0.553
2023Proposed longitudinal model with sentence-anatomy dropout proposed non-standard sliceBL-40.223split: test · report_scope=partial · prior_cxr_input=enabled · sentence_anatomy_dropout=enabledControllable Chest X-Ray Report Generation from Longitudinal Representations
Source quote
L483: 0.223
2023Proposed longitudinal model with sentence-anatomy dropout proposed non-standard sliceRG-L0.462split: test · report_scope=partial · prior_cxr_input=enabled · sentence_anatomy_dropout=enabledControllable Chest X-Ray Report Generation from Longitudinal Representations
Source quote
L485: 0.462
2023Proposed longitudinal model with sentence-anatomy dropout proposed non-standard sliceF1 (CE)0.672split: test · report_scope=partial · prior_cxr_input=enabled · sentence_anatomy_dropout=enabledControllable Chest X-Ray Report Generation from Longitudinal Representations
Source quote
L486: 0.672
2023DCL (row “Ours”) proposedCIDEr0.281split: testDynamic Graph Enhanced Contrastive Learning for Chest X-ray Report Generation
Source quote
L188: Ours │ 0.586 │ 0.163 │ 0.383 │ 0.193 │ Ours │ 0.281 │ 0.109 │ 0.284 │ 0.150