| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 150 of 205 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | CLEAR (MedGemma, Blur) proposed | AUPRC | 90.23% | split: test | Visually Irrelevant Hallucinations in Medical Vision-Language ModelsSource quoteL37: CXR, CLEAR improves AUPRC from 85.10% to 90.23%. Its |
| 2026 | IMT-CXR proposed | BL-1 | 38.6 | split: test | A unified multi-task framework enables interpretable chest radiograph analysisSource quoteL688: Ours │ 38.6 │ 13.1 │ 16.7 │ 27.5 │ 42.8 │ 31.5 │ 33.1 |
| 2026 | CompDiff proposed | FID | 64.3 | split: test · seeds=3 · training_steps=up to 30000 | CompDiff: Hierarchical Compositional Diffusion for Fair and Zero-Shot Intersectional Medical Image GenerationSource quoteL131: Table~\ref{tab:overall_and_equity} compares CompDiff against baselines across chest X-ray and fundus modalities. CompDiff achieves the best FID on both modalities (64.3 chest, 54.6 fundus). While FairDiffusion achieves slightly lower FID-RadImageNet on chest (6.2 vs 6.8), CompDiff outperforms on disease classification AUROC (0.82 vs 0.74), indicating better clinical feature alignment. MS-SSIM values remain in the acceptable range (0.25--0.75) for all models, confirming neither overfitting nor generation failure. Sex accuracy remains near-perfect across all methods. Slightly reduced race accuracy and increased age RMSE are expected trade-offs from HCN conditioning, offset by improved subgroup-level fairness below. |
| 2026 | FINO proposed | AUROC | 81.8 | split: test · params=2.7M label-supervised · subset=IID; 14 pathology labels · backbone=DINOv3 ViT-L/16 | Who Needs Labels? Adapting Vision Foundation Models With the Metadata You Already HaveSource quoteL201: \bf FINO (ours) │ 2.7M │ {\color{cyan}\Snow} │ {\bf 61.2} │ {\bf 53.1} │ \bf{52.9} │ {\bf 81.8} |
| 2026 | Bayesian Pairwise Merging (BPM) proposed non-standard slice | Macro decided win rate against uniform merge (RS) | 91.7% | split: test · feedback-budget=100 | The Missing Coefficients: Bayesian Pairwise Merging for Model PersonalizationSource quoteL321: RS │ \mrbhldiff{91.7}{50}\,\mrbci{90.3, 93.1} │ \mrbhldiff{88.4}{50}\,\mrbci{86.2, 90.4} │ \mrbhldiff{77.1}{50}\,\mrbci{74.7, 79.3} │ \mrbhldiff{78.7}{50}\,\mrbci{76.6, 80.7} │ \mrbhldiff{64.3}{50}\,\mrbci{62.5, 66.1} │ \mrbhldiff{76.1}{50}\,\mrbci{74.4, 77.8} |
| 2026 | Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposed | AUPRC | 87.78% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL226: S3: Case + Evidence + Claim │ 97.43 │ 87.78 │ 78.72 │ 92.03 │ 0.060 |
| 2026 | Evidence-only baseline (S2: Evidence + Claim; shared ModernBERT-large verifier) proposed | AUPRC | 35.11% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL225: S2: Evidence + Claim │ 82.63 │ 35.11 │ 62.79 │ 87.53 │ 0.255 |
| 2026 | Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposed | AUROC | 97.43% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL226: S3: Case + Evidence + Claim │ 97.43 │ 87.78 │ 78.72 │ 92.03 │ 0.060 |
| 2026 | Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposed | AUROC | 55.62% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL1297: AUROC │ 97.43 ± 0.27 [97--98] │ 97.24 ± 0.33 [97--98] │ 55.62 ± 1.50 [53--59] |
| 2026 | Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposed | AUPRC | 74.18% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL1298: AUPRC │ 87.78 ± 1.56 [85--91] │ 74.18 ± 3.20 [68--80] │ 21.73 ± 1.54 [19--25] |
| 2026 | AR-RRG proposed | B-4 | 0.152 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | B-1 | 0.425 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | B-2 | 0.292 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | B-3 | 0.210 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | RG-L | 0.322 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | CheXOne-drafted reports proposed | cases with reports judged comparable to or better than resident-written reports | 55\% | split: test · study=radiologist reader study · sample-size=80 radiographs · radiologists=11 | A Reasoning-Enabled Vision-Language Foundation Model for Chest X-ray InterpretationSource quoteL18: A clinical reader study demonstrates that CheXOne-drafted reports are comparable to or better than resident-written reports in 55% of cases, while effectively addressing clinical indications and enhancing both report writing and CXR interpretation efficiency. |
| 2025 | GPT-4o, Thought Graph Traversal (TGT) proposed | BLEU-4 | 9.84% | split: test · backbone=GPT-4o | Simple Radiology VLLM Test-time Scaling with Thought Graph TraversalSource quoteL200: TGT │ 29.25 │ 15.81 │ 8.95 │ 9.84 │ 14.12 │ 26.50 |
| 2025 | HuatuoGPT-Vision, Thought Graph Traversal (TGT) proposed | BLEU-4 | 11.34% | split: test · backbone=HuatuoGPT-Vision | Simple Radiology VLLM Test-time Scaling with Thought Graph TraversalSource quoteL208: TGT │ 32.99 │ 18.89 │ 10.85 │ 11.34 │ 14.36 │ 27.06 |
| 2025 | DLDM (disentangled latent diffusion model) proposed | Effectiveness Accuracy | 89.2% | split: test · intervention=do(A=black) | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL605: DLDM │ 89.2 │ 92.0 │ 93.7 |
| 2025 | Synthetic+Real mix model (maximal synthetic data) proposed | AUROC | 0.770 | split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL135: The synthetic+real model with maximal data achieved an AUROC of 0.770 (CI: 0.762-0.778) for the multi-label classification task on the in-distribution MIMIC-CXR test set. |
| 2025 | MedUnifier (w TIG) proposed | BLEU-1 (BL-1) | 41.5 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MedUnifier (w TIG) proposed | BLEU-4 (BL-4) | 12.9 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MedUnifier (w TIG) proposed | METEOR (MTR) | 22.7 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MedUnifier (w TIG) proposed | ROUGE-L (RG-L) | 34.0 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.75 | split: test · fine-tuned · view=frontal · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL137: Frontal │ 0.75 │ 0.65 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.73 | split: test · fine-tuned · view=lateral · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL138: Lateral │ 0.73 │ 0.65 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.75 | split: test · fine-tuned · view=frontal+lateral ensemble · fusion=late · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL139: Ensemble │ 0.75 │ 0.69 \multirow{3}{*}{Contrastive} |
| 2025 | SS-ACL proposed | BLEU-4 | 0.144 | split: test · test-samples=3858 | Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report GenerationSource quoteL447: {\color[HTML]{C00000} 0.144} |
| 2025 | SS-ACL proposed | Clinical efficacy macro F1 | 0.505 | split: test · categories=14 thoracic diseases · test-samples=3858 · clinical-labeler=CheXbert | Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report GenerationSource quoteL453: {\color[HTML]{C00000} 0.505} |
| 2025 | DDaTR (SwinT-B) proposed | F1_macro (Clinical Efficacy) | 0.441 | split: test · backbone=SwinT-B · averaging=macro | DDaTR: Dynamic Difference-aware Temporal Residual Network for Longitudinal Radiology Report GenerationSource quoteL313: Ours │ 0.438 │ 0.465 │ 0.441 (+0.049) │ 0.113 │ 0.162 │ 0.272 |
| 2025 | DiffRGenNet proposed | F1 | 0.483 | split: test | DiffRGenNet: Difference-aware Medical Report GenerationSource quoteL286: 0.483 |
| 2025 | MedAlign proposed | F1 | 95.25% | split: test · params=7B · backbone=LLaVA-Med-1.5 7B | MedAlign: A Synergistic Framework of Multimodal Preference Optimization and Federated Meta-Cognitive ReasoningSource quoteL417: MedAlign │ 95.64 │ 96.47 │ 95.25 │ 94.36 │ 22.99 │ 27.89 │ 16.33 │ 2.29 |
| 2025 | ARRA (text-generation-only LLM initialization) proposed | FID | 5.30 | split: test · subset=1,000 pairs · resolution=512×512 | Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation AlignmentSource quoteL309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576. |
| 2025 | ARRA (text-generation-only LLM initialization) proposed | CLIP-Score | 0.4532 | split: test · subset=1,000 pairs · backbone=CLIP · resolution=512×512 | Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation AlignmentSource quoteL309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576. |
| 2025 | ARRA-Adapt (general image-generation pretrained LLM initialization) proposed | FID | 4.15 | split: test · subset=1,000 pairs · resolution=512×512 | Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation AlignmentSource quoteL309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576. |
| 2025 | ARRA-Adapt (general image-generation pretrained LLM initialization) proposed | CLIP-Score | 0.4576 | split: test · subset=1,000 pairs · backbone=CLIP · resolution=512×512 | Unleashing the Potential of Large Language Models for Text-to-Image Generation Through Autoregressive Representation AlignmentSource quoteL309: On the MIMIC-CXR dataset, ARRA surpasses the best-performing baseline, LLM-CXR, reducing the FID from 5.88 to 5.30 and increasing the CLIP-Score from 0.4374 to 0.4532. The ARRA-Adapt variant delivers even stronger results, achieving an FID of 4.15 and a CLIP-Score of 0.4576. |
| 2025 | MeDiM proposed | FID | 16.60 | split: test | Discrete Diffusion Models with MLLMs for Unified Medical Multimodal GenerationSource quoteL34: 1) For medical image generation, MeDiM achieves state-of-the-art Frechet Inception Distances (FID) on the MIMIC-CXR~\citep{johnson2019mimic} and PathGen~\citep{sun2024pathgen} datasets, respectively (Tab.~\ref{tab_1} and Tab.~\ref{tab_2}; 16.60 FID and 24.19 FID), generating high-fidelity medical images across different modalities (Fig.~\ref{fig_qual}; robust and high visual quality). |
| 2025 | MeDiM proposed non-standard slice | METEOR (table label: MTR) | 0.265 | split: test | Discrete Diffusion Models with MLLMs for Unified Medical Multimodal GenerationSource quoteL275: MeDiM (Ours) │ MLLM │ 0.328 │ 0.185 │ 0.109 │ 0.265 │ 0.297 │ 0.185 │ 0.084 │ 0.037 │ 0.258 │ 0.226 |
| 2025 | MCA-RG (7B; listed as Ours) proposed | Example-based F1 | 0.408 | split: test · params=7B · scores=CE · averaging=example-based | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt] |
| 2025 | MCA-RG (7B; listed as Ours) proposed | Macro-based F1 | 0.335 | split: test · params=7B · scores=CE · averaging=macro-based | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt] |
| 2025 | ChexGen proposed | FID (CLIP features) | 0.89 | split: test · backbone=CLIP · sample-size=3500 cases · feature-extractor=CLIP | A Generative Foundation Model for Chest RadiographySource quoteL76: We assessed fidelity by calculating the FID (lower is better) between synthetic and real CXRs, extracting features from a pretrained general-purpose model (CLIP~\cite{radford2021learning}) and a domain-specific chest radiograph classifier (XRV~\cite{Cohen2022xrv}). ChexGen achieved substantially better fidelity with lower FID scores compared to MINIM-CXR~\cite{wang2024self} and RoentGen~\cite{chambon2022roentgen} (CLIP: 0.89 vs. 9.63 and 4.42; XRV: 0.57 vs. 8.29 and 6.80) (\textbf{\cref{fig:figure2}a}, p < 0.001). These results demonstrate that ChexGen better captures the distribution of real-world chest radiographs. |
| 2025 | ChexGen-balanced DenseNet121 model proposed | Weighted F1-score for worst-performing gender group | 0.387 | split: test · model=DenseNet121 · subgroup=worst-performing gender group · training-data=ChexGen-balanced | A Generative Foundation Model for Chest RadiographySource quoteL160: In addition to detecting model bias, we explored whether synthetic data could be used to further mitigate the observed bias. Using ChexGen, we generated additional training samples for underrepresented demographic subgroups until their representation matched that of the majority groups. Consequently, the augmented training data led to substantial improvements in model fairness across all demographic dimensions. For instance, the F1-Scores increased significantly for the worst group (gender: 0.338 to 0.387, race: 0.321 to 0.394, age: 0.363 to 0.419), while performance gaps between best and worst groups narrowed considerably with a relative reduction of up to 60% (gender: 2.5% to 1.6%, race: 2.9% to 1.2%, age: 2.3% to 1.2%) (\textbf{\cref{fig:figure6}d}). These results highlight the potential of CheXGen for generating synthetic data to enhance model fairness by detecting and mitigating bias. |
| 2025 | Domain-specific tokenizer (Specific) proposed | R-L | 0.344 | split: test · vocabulary-size=9.1k | Specialised or Generic? Tokenization Choices for Radiology Language ModelsSource quoteL167: Specific │ \ding{55} │ 9.1k │ 0.273 │ 0.364 │ 0.344 │ 0.514 │ 0.604 │ 0.270 │ 0.813 |
| 2025 | RadVLM+RL (GRPO) proposed | BERTScore (B-S) | 59.2 | split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findings | RadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement LearningSource quoteL117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86 |
| 2025 | RadVLM+RL (GRPO) proposed | GREEN (GRN) | 32.7 | split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findings | RadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement LearningSource quoteL117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86 |
| 2025 | RadVLM+RL (GRPO) proposed | RadCliQ (RCQ) | 0.86 | split: test · evaluation=unified-pipeline · image-input=single-frontal-CXR · report-type=findings | RadVLM-GRPO: Enhancing Chest X-ray Report Generation and Visual Grounding via Reinforcement LearningSource quoteL117: RadVLM+RL │ 8 │ 29.9 │ 59.2 │ 57.0 │ 33.4 │ 25.8 │ 32.7 │ 0.86 |
| 2025 | Weighted Avg (W-Avg; PRM scores) proposed | F1-CheXbert | 0.3575 | split: test · subset=full-unbalanced · strategy=weighted-average · generator=MAIRA-2 · candidates=128 · temperature=1.0 | Process Reward Models for Sentence-Level Verification of LVLM Radiology ReportsSource quoteL536: Our results (Figures~\ref{fig:bon_weighted_all} and \ref{fig:bon_nonweighted_all}) show that weighted strategies generally outperform non-weighted ones. For instance, Weighted Avg (W-Avg) using PRM scores improves F1-CheXbert by +5.0 points (0.3575 vs 0.3077 for non-weighted AvgProb) at N=128. Similarly, W-Avg boosts BERTScore by +0.001 points (0.8594 vs 0.8584) under the same conditions. The choice of N also impacts performance, with larger N generally leads to better results. |
| 2025 | HTSC-CIF proposed | METEOR | 0.177 | split: test | Medical Report Generation: A Hierarchical Task Structure-Based Cross-Modal Causal Intervention FrameworkSource quoteL230: Ours │ 0.413 │ 0.264 │ 0.193 │ 0.139 │ 0.177 │ 0.305 │ 0.386 |
| 2025 | HTSC-CIF proposed | ROUGE-L | 0.305 | split: test | Medical Report Generation: A Hierarchical Task Structure-Based Cross-Modal Causal Intervention FrameworkSource quoteL230: Ours │ 0.413 │ 0.264 │ 0.193 │ 0.139 │ 0.177 │ 0.305 │ 0.386 |
| 2025 | KIA proposed | BLEU-4 | 0.138 | split: test | KIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report GenerationSource quoteL535: Specifically, our KIA achieves 0.188 and 0.138 |
| 2025 | KIA proposed | CIDEr | 0.316 | split: test | KIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report GenerationSource quoteL538: Notably, our CIDEr scores of 0.641 and 0.316 on two datasets achieve considerable improvements of 9% and 6%, showing that reports generated by KIA are highly relevant to the image content and accurately reflect important information. This illustrates that the multitask implicit alignment we designed can effectively enhance the understanding of images and reports. |
| 2025 | KIA proposed non-standard slice | F1-Score | 0.461 | split: test · clinical-labels=14 CheXpert abnormality categories | KIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report GenerationSource quoteL477: 0.461 |
| 2025 | XMedGPT with the clinical reasoning framework proposed | Kendall’s tau-b (consistency) | 0.479 | split: test · fine-tuned · training=SFT and DPO · annotation=Chest-Imagenome-derived regions | Multi-Modal Explainable Medical AI Assistant for Trustworthy Human-AI CollaborationSource quoteL82: Training on the MIMIC-CXR dataset involved supervised fine-tuning (SFT) with 10,000 samples for long chain-of-thought reasoning, followed by reinforcement learning via Direct Preference Optimization (DPO) on 8,201 high/low-scoring report pairs. Evaluation on a test set annotated with Chest-Imagenome-derived regions revealed a 6.05% average improvement across clinical metrics (CheXpert F1, Radgraph F1, CheXpert Similarity) compared to non-reasoning baselines. DPO further refined report quality, elevating CheXpert F1 from 0.362 to 0.372. The model’s reasoning coherence was quantitatively validated using Kendall’s tau-b correlation, which measured alignment between intermediate reasoning paths and final conclusions. Scores of 0.479 (consistency) and 0.474 (completeness; both P < 0.05) indicate strong logical agreement. |
| 2025 | XMedGPT sentence-level uncertainty estimation proposed non-standard slice | AUC | 0.764 | split: test · method=semantic entropy with test-time scaling · subset=200 samples | Multi-Modal Explainable Medical AI Assistant for Trustworthy Human-AI CollaborationSource quoteL76: Having validated the effectiveness of our uncertainty estimation approach on medical VQA tasks, we extended it to the domain of medical report captioning for sentence-level uncertainty estimation, as illustrated in \Cref{fig:Uncertainty_method}. For each sentence generated in a medical report, our system generates multiple questions based on the sentence using a large language model. The consistency between the answers to these questions and the caption is assessed, with semantic entropy calculated to quantify uncertainty for each sentence. We evaluated the reliability of the uncertainty estimates on a subset (n = 200) of the MIMIC-CXR test dataset. As the number of questions increased from 1 to 5, the AUC improved from 0.676 to 0.764, reflecting a 13.02% enhancement. This substantial improvement demonstrates the effectiveness of combining semantic entropy with test-time scaling for estimating sentence-level uncertainty. |
| 2025 | CoD proposed | Horizontal lesion location accuracy | 0.514 | split: test · attribute=horizontal-lesion-location · evaluator=AttriBert | A Chain of Diagnosis Framework for Accurate and Explainable Radiology Report GenerationSource quoteL305: We compare our model with SOTA RRG methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, RGRG~\cite{TMK23}, R2GenGPT~\cite{WLW23b}, PromptMRG~\cite{JCL24}, and I3+C2FD~\cite{LTC24}. Moreover, we have added generalist foundation models for comparison, including Med-Flamingo~\cite{MHW23}, RadFM~\cite{WZZ23}, InternVL~\cite{CWW24}, LLaVA-Med~\cite{LWZ24}, and MedDr~\cite{HNW24}, which are trained to tackle various medical tasks rather than RRG alone. Table~\ref{tab:results_sota} shows the results on both IU X-Ray and MIMIC-CXR. First of all, we can see from the table that the proposed CoD obtains the best performance on most of the entries. To be specific, CoD obtains the best results on 11 out of 12 entries within CE metrics, demonstrating its superiority in generating clinically accurate reports. Notably, our method outperforms the other methods considerably in attribute accuracy, thanks to the effective guidance of QA prompts. For example, our method achieves 0.514 and 0.404 of horizontal lesion location accuracy on MIMIC and IU, which have gained 19.3% and 16.8% improvement respectively over the second best method PromptMRG. In terms of NLG metrcis, CoD obtains best results on four out of six entries, indicating the superior capability of LLMs in generating fluent and relevant texts. Interestingly, the performance of generalist foundation models are far behind that of specialists, where MedDr performs the best among generalists. This is understandable as generalists are supposed to deal with a number of tasks as well as out-of-domain data, which inevitably degrades their competitiveness on a specific task/data. |
| 2025 | REVTAF (full model: LRE and FVTAF enabled) proposed | Avg | 0.397 | split: test | Learnable Retrieval Enhanced Visual-Text Alignment and Fusion for Radiology Report GenerationSource quoteL189: Ours │ 0.465 │ 0.318 │ 0.235 │ 0.182 │ 0.199 │ 0.336 │ 0.628 │ 0.613 │ 0.592 │ 0.397 |
| 2025 | CXRAgent framework proposed | RaTEScore | 0.513 | split: test · subset=400 randomly selected cases | CXRAgent: Director-Orchestrated Multi-Stage Reasoning for Chest X-Ray InterpretationSource quoteL260: MIMIC-CXR. As demonstrated in Table~\ref{tab:report1}, our proposed CXRAgent framework achieves superior performance in chest X-ray report generation, attaining the highest RaTEScore of 0.513 among all evaluated models. This metric, which specifically measures the accuracy of clinical entity recognition, highlights our method's exceptional capability in identifying and describing medically relevant findings with precision. The RaTEScore performance represents a significant advancement over general-purpose multimodal models such as GPT-4o (0.429) and Qwen-VL-Max (0.415), demonstrating the effectiveness of our approach to report generation. In terms of overall report quality assessment using the LLMScore metric, our GPT-based implementation achieves a score of 2.77, ranking second only to LLaVA-Rad (2.99), which is specifically optimized for radiology report generation. This performance is particularly noteworthy given that LLaVA-Rad employs dedicated training strategies tailored specifically for this task. Compared to baseline models, our framework demonstrates substantial improvements, with relative enhancements of 34.5% over GPT-4o (2.06) and 23.1% over MedRAX with GPT backbone (2.25). These improvements underscore the effectiveness of our multi-stage reasoning framework in generating clinically coherent and comprehensive radiology reports. The consistent performance across both evaluation dimensions—entity-level recognition (RaTEScore) and overall quality (LLMScore)—validates the robustness of our approach. The integration of EDV ensures that generated reports maintain high factual accuracy, while the adaptive team collaboration mechanism enables comprehensive coverage of clinical findings. This balanced performance across different assessment criteria demonstrates the framework's capability to handle the complex requirements of clinical report generation, where both precise entity extraction and overall narrative quality are essential for practical utility. |
| 2024 | D-KD (RadBERT-Roberta-4m-document, contrastive) proposed non-standard slice | Accuracy | 85.52% | split: test · params=4m · subset=p11 high-confidence-filtered test documents · backbone=RadBERT-Roberta-4m-document | Integrating ChatGPT into Secure Hospital Networks: A Case Study on Improving Radiology Report AnalysisSource quoteL176: \begin{tabular}[c]{@{}c@{}}RadBERT-Roberta\\-4m-document\\contrastive │ \begin{tabular}[c]{@{}c@{}}85.52\\(+ 0.35) │ \begin{tabular}[c]{@{}c@{}}0.858\\(+0.026) │ \begin{tabular}[c]{@{}c@{}}0.840\\(-0.012) │ \begin{tabular}[c]{@{}c@{}}0.901\\(+0.055) |
| 2024 | FSE-1 proposed | BL-1 (BLEU-1) | 0.397 | split: test · reference-report-truncation=M_gt=80 | Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report GenerationSource quoteL229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency. |
| 2024 | FSE-1 proposed | CX14 (CheXbert micro-F1, 14 categories) | 0.470 | split: test · reference-report-truncation=M_gt=80 | Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report GenerationSource quoteL229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency. |
| 2024 | CLIP(SapBERT)+AHIVE proposed | CE(11/5) micro-average F1 | 0.678 | split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impression | AHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report RetrievalSource quoteL499: 0.678 |
| 2024 | CLIP(SapBERT)+AHIVE proposed | CE(11) micro-average F1 | 0.604 | split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impression | AHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report RetrievalSource quoteL498: 0.604 |
| 2024 | CLIP(SapBERT)+AHIVE proposed | CE(13+NL) micro-average F1 | 0.685 | split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impression | AHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report RetrievalSource quoteL500: 0.685 |
| 2024 | MDAgents (Adaptive; GPT-4o-mini) proposed | Accuracy | 56.0% | split: test · 0-shot | MDAgents: An Adaptive Collaboration of LLMs for Medical Decision-MakingSource quoteL525: \shortcolorbox{MDAgents (Ours)} │ 75.0 │ 89.0 │ 59.0 │ 67.0 │ 56.0 |
| 2024 | FactMM-RAG proposed | F1CheXbert | 0.605 | split: test · retrieval-setting=multimodal | Fact-Aware Multimodal Retrieval Augmentation for Accurate Medical Radiology Report GenerationSource quoteL269: FactMM-RAG │ 0.605 │ 0.249 │ 0.297 │ 0.547 │ 0.491 │ 0.174 │ 0.237 │ 0.467 |
| 2024 | FactMM-RAG proposed | F1RadGraph | 0.249 | split: test · retrieval-setting=multimodal | Fact-Aware Multimodal Retrieval Augmentation for Accurate Medical Radiology Report GenerationSource quoteL269: FactMM-RAG │ 0.605 │ 0.249 │ 0.297 │ 0.547 │ 0.491 │ 0.174 │ 0.237 │ 0.467 |
| 2024 | FITA proposed | BLEU-1 | 0.411 | split: test | FITA: Fine-grained Image-Text Aligner for Radiology Report GenerationSource quoteL107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326 |
| 2024 | FITA proposed | METEOR | 0.172 | split: test | FITA: Fine-grained Image-Text Aligner for Radiology Report GenerationSource quoteL107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326 |
| 2024 | FITA proposed | ROUGE-L | 0.295 | split: test | FITA: Fine-grained Image-Text Aligner for Radiology Report GenerationSource quoteL107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326 |
| 2024 | SGRRG proposed | BLEU-1 | 0.434 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | SGRRG proposed | BLEU-4 | 0.149 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | SGRRG proposed | METEOR | 0.173 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | SGRRG proposed non-standard slice | Macro-average precision (clinical efficacy) | 0.440 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | SGRRG proposed non-standard slice | Macro-average recall (clinical efficacy) | 0.323 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | SGRRG proposed non-standard slice | Macro-average F1 (clinical efficacy) | 0.332 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | DiCoM proposed | AUPR | .948 | split: test · linear-probe | DiCoM - Diverse Concept Modeling towards Enhancing Generalizability in Chest X-Ray StudiesSource quoteL214: DiCoM (ours) │ .865 │ .969 │ \multicolumn{1}{c|}{.852} │ .861 │ .987 │ .930 │ .843 │ {\ul .948} │ \multicolumn{1}{c|}{{\ul .802}} │ .840 │ .947 │ .807 |
| 2024 | DiCoM proposed | AUPR | .947 | split: test · fine-tuned | DiCoM - Diverse Concept Modeling towards Enhancing Generalizability in Chest X-Ray StudiesSource quoteL214: DiCoM (ours) │ .865 │ .969 │ \multicolumn{1}{c|}{.852} │ .861 │ .987 │ .930 │ .843 │ {\ul .948} │ \multicolumn{1}{c|}{{\ul .802}} │ .840 │ .947 │ .807 |
| 2024 | MedRAT proposed | CE Recall | 0.265 | split: test · paired-data=0% | MedRAT: Unpaired Medical Report Generation via Auxiliary TasksSource quoteL340: MedRAT {(Ours)} │ 0.285 │ 0.265 │ 0.227 |
| 2024 | MedRAT proposed | B-1 | 0.365 | split: test · paired-data=0% | MedRAT: Unpaired Medical Report Generation via Auxiliary TasksSource quoteL321: MedRAT │ 0.365 │ 0.086 │ 0.132 │ 0.251 │ 0.138 │ 0.398 │ 0.455 │ 0.129 │ 0.171 │ 0.349 │ 0.204 │ 0.427 |
| 2024 | ChEX (VinDr-CXR and MIMIC-CXR training) proposed | Ex-F1-14 | 58.76 | split: test · 0-shot | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}} |
| 2024 | ChEX (VinDr-CXR and MIMIC-CXR training) proposed | Mic-F1-5+ | 61.03 | split: test · 0-shot | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}} |
| 2024 | ChEX (VinDr-CXR and MIMIC-CXR training) proposed | Mac-F1-5+ | 55.85 | split: test · 0-shot | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}} |
| 2024 | XReal proposed | Avg. Radiologist Score — Anatomy | 4.167 | split: test · evaluation=radiologist-rating · rating-dimension=anatomy | XReal: Realistic Anatomy and Pathology-Aware X-ray Generation via Controllable Diffusion ModelSource quoteL193: To solidify our assessment of the generated X-rays' clinical realism, two expert radiologists reviewed the images in a blind review setting. As shown in Table \ref{tab:results}, XReal outperformed other methods by a large margin with scores of 4.167 and 4.130 for anatomy and pathology, respectively, while surpassing real images in both anatomy (+0.536) and pathology realism (+0.569) evaluation. This improvement, particularly over real images, can be attributed to a number of factors, including XReal's ability to accurately generate all anatomical structures based on the provided anatomical mask (m_a), making both the anatomy and pathology clearer. Additionally, since the anatomical mask was obtained using a segmentation model, XReal can potentially avoid including artifacts that might be present in the real images but are not captured in the mask. This can lead to clearer anatomy and more evident pathology manifestations. However, it would be important to investigate incorporating X-ray artifacts in the future. |
| 2024 | XReal proposed | Avg. Radiologist Score — Pathology | 4.130 | split: test · evaluation=radiologist-rating · rating-dimension=pathology | XReal: Realistic Anatomy and Pathology-Aware X-ray Generation via Controllable Diffusion ModelSource quoteL193: To solidify our assessment of the generated X-rays' clinical realism, two expert radiologists reviewed the images in a blind review setting. As shown in Table \ref{tab:results}, XReal outperformed other methods by a large margin with scores of 4.167 and 4.130 for anatomy and pathology, respectively, while surpassing real images in both anatomy (+0.536) and pathology realism (+0.569) evaluation. This improvement, particularly over real images, can be attributed to a number of factors, including XReal's ability to accurately generate all anatomical structures based on the provided anatomical mask (m_a), making both the anatomy and pathology clearer. Additionally, since the anatomical mask was obtained using a segmentation model, XReal can potentially avoid including artifacts that might be present in the real images but are not captured in the mask. This can lead to clearer anatomy and more evident pathology manifestations. However, it would be important to investigate incorporating X-ray artifacts in the future. |
| 2024 | IVGN proposed | BL-2 | 0.236 | split: test | Intensive Vision-guided Network for Radiology Report GenerationSource quoteL293: IVGN │ 0.377 │ 0.236 │ 0.158 │ 0.112 │ 0.144 │ 0.280 │ 0.415 │ 0.442 │ 0.398 |
| 2024 | IVGN proposed | F1-score (CE) | 0.398 | split: test | Intensive Vision-guided Network for Radiology Report GenerationSource quoteL293: IVGN │ 0.377 │ 0.236 │ 0.158 │ 0.112 │ 0.144 │ 0.280 │ 0.415 │ 0.442 │ 0.398 |
| 2024 | BiCAL CheSS proposed non-standard slice | Recall | 0.274 | split: test · active-learning · runs=3 · encoder=CheSS · queried-labels=1000 · training-subset=stratified 10% · evaluation-labels=CheXpert | BiCAL: Bi-directional Contrastive Active Learning for Clinical Report GenerationSource quoteL208: 0.274 |
| 2024 | BiCAL CheSS proposed non-standard slice | F-1 Score | 0.219 | split: test · active-learning · runs=3 · encoder=CheSS · queried-labels=1000 · training-subset=stratified 10% · evaluation-labels=CheXpert | BiCAL: Bi-directional Contrastive Active Learning for Clinical Report GenerationSource quoteL209: 0.219 |
| 2024 | Hard-CFT (Sex CFs) proposed | AUC | 75.4% | split: test · counterfactuals=sex | Mitigating Attribute Amplification in Counterfactual Image GenerationSource quoteL111: Hard-CFT │ \unint{75.4 {(\downarrow 18.4)}} │ \interv{79.6 {(\downarrow 20.0)}} │ \unint{89.8 {(\downarrow 4.4)}} |
| 2024 | Soft-CFT (Sex CFs) proposed | AUC | 92.4% | split: test · counterfactuals=sex | Mitigating Attribute Amplification in Counterfactual Image GenerationSource quoteL112: Soft-CFT │ \unint{92.4 {(\downarrow 1.4)}} │ \interv{90.0 {(\downarrow 9.6)}} │ \unint{94.0 {(\downarrow 0.2)}} |
| 2024 | Hard-CFT (Sex CFs) proposed | AUC | 79.6% | split: test · counterfactuals=sex | Mitigating Attribute Amplification in Counterfactual Image GenerationSource quoteL111: Hard-CFT │ \unint{75.4 {(\downarrow 18.4)}} │ \interv{79.6 {(\downarrow 20.0)}} │ \unint{89.8 {(\downarrow 4.4)}} |
| 2024 | Soft-CFT (Sex CFs) proposed | AUC | 90.0% | split: test · counterfactuals=sex | Mitigating Attribute Amplification in Counterfactual Image GenerationSource quoteL112: Soft-CFT │ \unint{92.4 {(\downarrow 1.4)}} │ \interv{90.0 {(\downarrow 9.6)}} │ \unint{94.0 {(\downarrow 0.2)}} |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (INTER.) proposed | BL-1 | 0.364 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediate | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL750: 0.364 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (FINAL) proposed | BL-1 | 0.402 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=final | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL757: 0.402 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (INTER.) proposed | BL-4 | 0.093 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediate | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL753: 0.093 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (FINAL) proposed | BL-4 | 0.128 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=final | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL760: 0.128 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (INTER.) proposed | RG-L | 0.261 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediate | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL755: 0.261 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (FINAL) proposed | RG-L | 0.291 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=final | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL762: 0.291 |
| 2024 | Fair Diagnosis (ResNet50) proposed | ACC | 84.67% | split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=gender | Fair Diagnosis: Leveraging Causal Modeling to Mitigate Medical BiasSource quoteL278: Resnet50 │ 84.67 │ 62.46 │ 1.78 │ 2.39 │ 1.19 |
| 2024 | Fair Diagnosis (ResNet50) proposed non-standard slice | ADF (column label: ADF-e-3) | 1.19 | split: test · η=0.2 · backbone=ResNet50 · metric_scale=e-3 · train_test_split=90/10 · sensitive_attribute=gender | Fair Diagnosis: Leveraging Causal Modeling to Mitigate Medical BiasSource quoteL278: Resnet50 │ 84.67 │ 62.46 │ 1.78 │ 2.39 │ 1.19 |
| 2024 | GPT4V + FactCheXcker (updated report) proposed | MAE | 1.15 cm | split: test · model=GPT4V · report=FactCheXcker-updated | FactCheXcker: Mitigating Measurement Hallucinations in Chest X-ray Report Generation ModelsSource quoteL611: GPT4V │ 0.58 │ 0.22 │ 0.32 │ 0.60 │ 1.15 │ 3.08 │ 0.85 │ 0.74 │ 0.79 │ 0.65 |
| 2024 | CheXagent + FactCheXcker (updated report) proposed | MAE | 1.20 cm | split: test · model=CheXagent · report=FactCheXcker-updated | FactCheXcker: Mitigating Measurement Hallucinations in Chest X-ray Report Generation ModelsSource quoteL613: CheXagent │ 0.76 │ 0.36 │ 0.49 │ 0.68 │ 1.20 │ 3.13 │ 0.81 │ 0.88 │ 0.84 │ 0.64 |
| 2024 | Cvt2distilgpt2 + FactCheXcker (updated report) proposed | MAE | 1.35 cm | split: test · model=Cvt2distilgpt2 · report=FactCheXcker-updated | FactCheXcker: Mitigating Measurement Hallucinations in Chest X-ray Report Generation ModelsSource quoteL615: Cvt2distilgpt2 │ 0.72 │ 0.53 │ 0.61 │ 0.75 │ 1.35 │ 4.87 │ 0.70 │ 0.81 │ 0.75 │ 0.63 |
| 2024 | MedImageInsight proposed | CheXbert Micro-avg F1-14 | 53.6 | split: test · params=0.4B | MedImageInsight: An Open-Source Embedding Model for General Domain Medical ImagingSource quoteL203: MedImageInsight\xspace \tnote{a} │ 53.6 │ 57.2 │ 37.0 │ 48.3 │ 53.3 │ 58.6 │ 40.7 │ 51.7 │ 25.5 │ 28.8 │ 37.0 │ 15.2 │ 31.6 |
| 2024 | MMVM VAE (lateral representation zL) proposed | AUROC | 78.7% | split: test · evaluation=binary random forest · representation=lateral unimodal latent zL | Unity by Diversity: Improved Representation Learning for Multimodal VAEsSource quoteL294: PoE VAE’s frontal representations zF (MMVM zL: 78.7%, PoE zF : 78.5%), even though the lateral modality seems generally less informative (supervised xL: 79.0%, xF : 81.7%) for this task. The same observation can be made for other labels (see detailed results and discussion in Appendix B.7.3). |
| 2024 | Memory Alignment Network (MA; proposed model) proposed | BLEU-1 | 0.396 | split: test | Automatic Radiology Reports Generation via Memory Alignment NetworkSource quoteL254: 0.396 |
| 2024 | M4CXR proposed non-standard slice | mF1-14 (CheXbert) | 60.6 | split: test · subset=frontal images; 2,461 images | M4CXR: Exploring Multitask Potentials of Multimodal Large Language Models for Chest X-Ray InterpretationSource quoteL326: 60.6 │ 61.8 │ 40.0 │ 49.5 │ 53.6 │ 21.8 │ 33.9 │ 10.3 │ 28.5 │ 2,461 |
| 2024 | RayDINO proposed | RadGraph F1 | 23.9 | split: test | Advancing human-centric AI for robust X-ray analysis through holistic self-supervised learningSource quoteL278: RayDINO │ 13.8\ci{13.4}{14.2} │ 30.3\ci{29.7}{30.8} │ 23.9\ci{23.3}{24.6} │ 44.8\ci{44.0}{45.6} │ 3.07\ci{3.04}{3.11} │ 36.1\ci{34.4}{37.6} │ 54.8\ci{53.5}{56.0} |
| 2024 | RayDINO proposed | CheXbert score | 44.8 | split: test | Advancing human-centric AI for robust X-ray analysis through holistic self-supervised learningSource quoteL278: RayDINO │ 13.8\ci{13.4}{14.2} │ 30.3\ci{29.7}{30.8} │ 23.9\ci{23.3}{24.6} │ 44.8\ci{44.0}{45.6} │ 3.07\ci{3.04}{3.11} │ 36.1\ci{34.4}{37.6} │ 54.8\ci{53.5}{56.0} |
| 2024 | RayDINO proposed | RadCliQ | 3.07 | split: test | Advancing human-centric AI for robust X-ray analysis through holistic self-supervised learningSource quoteL278: RayDINO │ 13.8\ci{13.4}{14.2} │ 30.3\ci{29.7}{30.8} │ 23.9\ci{23.3}{24.6} │ 44.8\ci{44.0}{45.6} │ 3.07\ci{3.04}{3.11} │ 36.1\ci{34.4}{37.6} │ 54.8\ci{53.5}{56.0} |
| 2024 | DAug (Full; DAug feature augmentation, Hybrid Contrastive criterion) proposed | mAP@K, wAvg | .799 | split: test · K=5 · backbone=CLIP ViT-Base/32 · direction=report-to-image | DAug: Diffusion-based Channel Augmentation for Radiology Image Retrieval and ClassificationSource quoteL146: DAug (Full) │ DAug │ Hybrid Contrastive │ .77 │ .86 │ .83 │ .89 │ .64 │ .79 │ .80 │ .71 │ .81 │ .64 │ .79 │ .66 │ .76 │ .79 │ .767 │ .799 |
| 2024 | DAug (Full; DAug feature augmentation, Hybrid Contrastive criterion) proposed | mAP@K, wAvg | .771 | split: test · K=5 · backbone=CLIP ViT-Base/32 · direction=image-to-image | DAug: Diffusion-based Channel Augmentation for Radiology Image Retrieval and ClassificationSource quoteL151: DAug (Full) │ DAug │ Hybrid Contrastive │ .72 │ .86 │ .83 │ .88 │ .53 │ .78 │ .79 │ .65 │ .81 │ .47 │ .77 │ .59 │ .69 │ .74 │ .721 │ .771 |
| 2024 | Generalized orthogonalization (C^h) proposed | Estimated influence coefficient of age on predictions | -0.011 | split: test · embedding=CXR foundation-model embeddings · dimensions=111 (SVD-reduced) | Generalizing Orthogonalization for Models with Non-LinearitiesSource quoteL44: Generalized orthogonalization \mathcal{C}^h │ 0.001 (0.994)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.011 (0.689)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.001 (0.753)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.000 (0.904)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} |
| 2024 | Generalized orthogonalization (C^h) proposed | Estimated influence coefficient of Race (Black) on predictions | -0.001 | split: test · embedding=CXR foundation-model embeddings · dimensions=111 (SVD-reduced) | Generalizing Orthogonalization for Models with Non-LinearitiesSource quoteL44: Generalized orthogonalization \mathcal{C}^h │ 0.001 (0.994)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.011 (0.689)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.001 (0.753)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} │ -0.000 (0.904)\,\makebox[\symbolwidth]{\textcolor{cb-green-sea}{\ding{51}}} |
| 2024 | GenX+AC (t=0)_1 proposed | F1 score | 54.3 | split: test · backbone=ResNet-18 · auditing-component=AC · confidence-threshold=0 | Quality Control for Radiology Report Generation Models via Auxiliary Auditing ComponentsSource quoteL192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3 |
| 2024 | GenX+AC (t=0.8)_1 proposed | F1 score | 58.4 | split: test · backbone=ResNet-18 · auditing-component=AC · confidence-threshold=0.8 | Quality Control for Radiology Report Generation Models via Auxiliary Auditing ComponentsSource quoteL192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3 |
| 2023 | BiomedJourney proposed | Mean AUROC (pathology classifier) | 80.54 | split: test | BiomedJourney: Counterfactual Biomedical Image Generation by Instruction-Learning from Multimodal Patient JourneysSource quoteL273: BiomedJourney\xspace{} (Ours) │ 72.08 │ 73.76 │ 88.64 │ 88.11 │ 80.12 │ 80.54 │ {10.9} |
| 2023 | Classifier trained on D_distill proposed | f-\theta (class) AUC | 0.810 | split: test · subset=40,000 training images · backbone=DenseNet-121 · test_size=3,101 images | Privacy Distillation: Reducing Re-identification Risk of Multimodal Diffusion ModelsSource quoteL203: D-distill │ 1.34 % │ 0.810 │ 0.611-0.272 |
| 2023 | METransformer proposed | CIDEr | 0.362 | split: test | METransformer: Radiology Report Generation by Transformer with Multiple Learnable Expert TokensSource quoteL158: Ours(METransformer) │ 0.386 │ 0.250 │ 0.169 │ 0.124 │ 0.291 │ 0.152 │ 0.362 |
| 2023 | XrayGPT (+ RadVicuna; row 4) proposed | R-1 | 0.3213 | split: test | XrayGPT: Chest Radiographs Summarization using Large Medical Vision-Language ModelsSource quoteL115: + RadVicuna │ 0.3213 │ 0.0912 │ 0.1997 |
| 2023 | XrayGPT (+ RadVicuna; row 4) proposed | R-2 | 0.0912 | split: test | XrayGPT: Chest Radiographs Summarization using Large Medical Vision-Language ModelsSource quoteL115: + RadVicuna │ 0.3213 │ 0.0912 │ 0.1997 |
| 2023 | XrayGPT (+ RadVicuna; row 4) proposed | R-L | 0.1997 | split: test | XrayGPT: Chest Radiographs Summarization using Large Medical Vision-Language ModelsSource quoteL115: + RadVicuna │ 0.3213 │ 0.0912 │ 0.1997 |
| 2023 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposed | AUC | 79.53% | split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteL41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2023 | Proposed method (OURS; RadBloomz fine-tuned with detected-abnormality prompts) proposed | ROUGE-L | 0.373 | split: test · fine-tuned · prompt=detected abnormalities and probabilities · generation-length=128 tokens | Generation of Radiology Findings in Chest X-Ray by Leveraging Collaborative KnowledgeSource quoteL147: OURS │ 0.373 |
| 2023 | CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposed | BLEU4 | 25.58 | split: test · evaluation=RadSum23 public test | KU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report SummarizationSource quoteL148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96 |
| 2023 | CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposed | ROUGE-L | 47.75 | split: test · evaluation=RadSum23 public test | KU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report SummarizationSource quoteL148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96 |
| 2023 | CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposed | Bertscore | 64.80 | split: test · evaluation=RadSum23 public test | KU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report SummarizationSource quoteL148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96 |
| 2023 | CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposed | F1-cheXbert | 76.29 | split: test · evaluation=RadSum23 public test | KU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report SummarizationSource quoteL148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96 |
| 2023 | CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposed | F1-Radgraph | 50.96 | split: test · evaluation=RadSum23 public test | KU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report SummarizationSource quoteL148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96 |
| 2023 | ELIXR proposed | NDCG@5 | 0.76 | split: test · cutoff=5 · queries=19 | ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encodersSource quoteL25: AUCs of 0.893 and 0.898 across five findings (atelectasis, cardiomegaly, consolidation, pleural effusion, and pulmonary edema) for 1% (~2,200 images) and 10% (~22,000 images) training data), and semantic search (0.76 normalized discounted cumulative gain (NDCG) across nineteen queries, including perfect retrieval on twelve of them). Compared to existing data-efficient methods including supervised contrastive learning (SupCon), ELIXR required two orders of magnitude less data to reach similar performance. ELIXR also showed promise on CXR vision-language tasks, demonstrating overall accuracies of 58.7% and 62.5% on visual question answering and report quality assurance tasks, respectively. These results suggest that ELIXR is a robust and versatile approach to CXR AI. |
| 2023 | ELIXR-B proposed | Accuracy | 62.5% | split: test · section=impression | ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encodersSource quoteL557: On more challenging text-generation tasks, ELIXR-B demonstrated overall accuracies of 58.7% and 54.8% on two visual question answering (VQA) datasets, VQA-RAD (CXR-only questions) (Table 5) and MIMIC-CXR test (Table 6), as well as 62.5% on report quality assurance (QA) on |
| 2023 | PromptMRG proposed | F1 score (clinical efficacy) | 0.476 | split: test · evaluation=CheXbert 14-disease-label clinical efficacy | PromptMRG: Diagnosis-Driven Prompts for Medical Report GenerationSource quoteL190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details. |
| 2023 | C^2M-DoT proposed | BLEU-1 | 0.4842 | split: test | C^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer networkSource quoteL275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850 |
| 2023 | C^2M-DoT proposed | ROUGE-L | 0.3850 | split: test | C^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer networkSource quoteL275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850 |
| 2023 | Latent Diffusion Models proposed | FID | 8.8325 | split: test · resolution=512×512 | Generative AI for Medical Imaging: extending the MONAI FrameworkSource quoteL59: MIMIC-CXR │ 2D Chest X-ray │ 512 × 512 │ 8.8325 │ 0.4276 │ 0.9834 |
| 2023 | Pragmatic LLaMA proposed | Pos F1 | 0.307 | split: test · fine-tuned · epochs=3 · section=impression · training-examples=18264 | Pragmatic Radiology Report GenerationSource quoteL383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158 |
| 2023 | Pragmatic Retrieval proposed | Neg F1-5 | 0.156 | split: test · section=impression · metric-subset=five most frequent negative labels | Pragmatic Radiology Report GenerationSource quoteL382: Pragmatic Retrieval │ 0.293 │ 0.403 │ 0.103 │ 0.072 │ -0.103 │ 0.078 │ -0.084 │ \bf 0.077 │ \bf 0.156 │ 0.445 |
| 2023 | Pragmatic LLaMA proposed | Neg F1-5 | 0.127 | split: test · fine-tuned · epochs=3 · section=impression · metric-subset=five most frequent negative labels · training-examples=18264 | Pragmatic Radiology Report GenerationSource quoteL383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158 |
| 2023 | KiUT proposed | BLEU-1 | 0.393 | split: test · input-images=single-image | KiUT: Knowledge-injected U-Transformer for Radiology Report GenerationSource quoteL229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321 |
| 2023 | KiUT proposed | F1 | 0.321 | split: test · input-images=single-image · label-source=CheXpert | KiUT: Knowledge-injected U-Transformer for Radiology Report GenerationSource quoteL229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321 |
| 2023 | LA-SSL proposed | Precision (old subgroup) | 40.00% | split: test · subgroup=older than 90 | Making Self-supervised Learning Robust to Spurious Correlation via Learning-speed Aware SamplingSource quoteL339: LA-SSL │ 32.43 │ 16.07 │ 83.47 │ 74.89 │ 63.65 │ 40.00 │ 73.42 │ 34.83 |
| 2023 | Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposed | BLEU-3 (BL-3) | 0.162 | split: test | Enhanced Knowledge Injection for Radiology Report GenerationSource quoteL171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217 |
| 2023 | Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposed | BLEU-4 (BL-4) | 0.119 | split: test | Enhanced Knowledge Injection for Radiology Report GenerationSource quoteL171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217 |
| 2023 | Proposed longitudinal model with sentence-anatomy dropout proposed | BL-4 | 0.246 | split: test · report_scope=full · prior_cxr_input=enabled · sentence_anatomy_dropout=enabled | Controllable Chest X-Ray Report Generation from Longitudinal RepresentationsSource quoteL360: 0.246 |
| 2023 | Proposed longitudinal model with sentence-anatomy dropout proposed | RG-L | 0.423 | split: test · report_scope=full · prior_cxr_input=enabled · sentence_anatomy_dropout=enabled | Controllable Chest X-Ray Report Generation from Longitudinal RepresentationsSource quoteL362: 0.423 |
| 2023 | Proposed longitudinal model with sentence-anatomy dropout proposed | F1 (CE) | 0.553 | split: test · report_scope=full · prior_cxr_input=enabled · sentence_anatomy_dropout=enabled | Controllable Chest X-Ray Report Generation from Longitudinal RepresentationsSource quoteL363: 0.553 |
| 2023 | Proposed longitudinal model with sentence-anatomy dropout proposed non-standard slice | BL-4 | 0.223 | split: test · report_scope=partial · prior_cxr_input=enabled · sentence_anatomy_dropout=enabled | Controllable Chest X-Ray Report Generation from Longitudinal RepresentationsSource quoteL483: 0.223 |
| 2023 | Proposed longitudinal model with sentence-anatomy dropout proposed non-standard slice | RG-L | 0.462 | split: test · report_scope=partial · prior_cxr_input=enabled · sentence_anatomy_dropout=enabled | Controllable Chest X-Ray Report Generation from Longitudinal RepresentationsSource quoteL485: 0.462 |
| 2023 | Proposed longitudinal model with sentence-anatomy dropout proposed non-standard slice | F1 (CE) | 0.672 | split: test · report_scope=partial · prior_cxr_input=enabled · sentence_anatomy_dropout=enabled | Controllable Chest X-Ray Report Generation from Longitudinal RepresentationsSource quoteL486: 0.672 |
| 2023 | DCL (row “Ours”) proposed | CIDEr | 0.281 | split: test | Dynamic Graph Enhanced Contrastive Learning for Chest X-ray Report GenerationSource quoteL188: Ours │ 0.586 │ 0.163 │ 0.383 │ 0.193 │ Ours │ 0.281 │ 0.109 │ 0.284 │ 0.150 |