MIMIC-CXR

263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

68.772.676.580.32024M-FLAG: 69.5 (2023)DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained): 79.53 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 4 of 4 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025MedAlign proposedRadGraph F110.92peft · backbone=LLaVA-Med-1.5 · fine-tuning=without LoRAEnhancing Medical Large Vision-Language Models via Alignment Distillation
Source quote
L441: MedAlign\xspace │ 4.51 │ 18.43 │ 20.80 │ 86.00 │ 25.67 │ 10.92 │ 42.03
2025A^3Tune baselineRadGraph F110.52peft · backbone=LLaVA-Med-1.5 · fine-tuning=without LoRAEnhancing Medical Large Vision-Language Models via Alignment Distillation
Source quote
L440: A^3Tune │ 4.22 │ 18.02 │ 20.69 │ 85.75 │ 25.37 │ 10.52 │ 42.15
2023Clin-T5-Large + LoRA proposedBLEU18.9peft · params=738M · backbone=Clin-T5-Large · adaptation=LoRARadAdapt: Radiology Report Summarization via Lightweight Domain Adaptation of Large Language Models
Source quote
L175: LoRA │ large │ 18.9 │ 44.5 │ 90.0 │ 41.8 │ 70.9
2023Clin-T5-Large + prefix tuning baselineBLEU16.1peft · params=738M · backbone=Clin-T5-Large · adaptation=prefix-tuningRadAdapt: Radiology Report Summarization via Lightweight Domain Adaptation of Large Language Models
Source quote
L174: \multirow{2}{*}{MIMIC-CXR} │ prefix tuning │ large │ 16.1 │ 43.4 │ 89.7 │ 41.0 │ 70.2