MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 60 of 60 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | AR-RRG proposed | B-4 | 0.152 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | B-1 | 0.425 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | B-2 | 0.292 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | B-3 | 0.210 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | AR-RRG proposed | RG-L | 0.322 | split: test · fine-tuned · params=7B | AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report GenerationSource quoteL1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B- |
| 2026 | LLaVA-TA proposed | RadGraph F1 | 31.1 | fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · evaluation_setting=in-distribution | Rethinking Radiology Report Generation: From Narrative Flow to Topic-Guided FindingsSource quoteL601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs. |
| 2026 | LLaVA-T ablation | RadGraph F1 | 1.6 | fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · anatomical_masks=excluded · evaluation_setting=in-distribution | Rethinking Radiology Report Generation: From Narrative Flow to Topic-Guided FindingsSource quoteL601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs. |
| 2025 | MoColl + tuned VQA model proposed | ROUGE-L | 0.2349 | fine-tuned | MoColl: Agent-Based Specific and General Model Collaboration for Image CaptioningSource quoteL218: MoColl + tuned VQA model (Ours) │ \bf{0.2749} │ \bf{0.1454} │ \bf{0.0897} │ \bf{0.0655} │ \bf{0.1126} │ \bf{0.2349} │ \bf{0.0932} |
| 2025 | MoColl + aligned VLM proposed | ROUGE-L | 0.1906 | fine-tuned | MoColl: Agent-Based Specific and General Model Collaboration for Image CaptioningSource quoteL217: MoColl + aligned VLM (Ours) │ 0.2515 │ 0.1290 │ 0.0746 │ 0.0456 │ 0.0947 │ 0.1906 │ 0.0566 |
| 2025 | IDEFICS+ADA-Steal proposed | RG-L | 21.4 | fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100 | Medical Multimodal Model Stealing Attacks via Adversarial Domain AlignmentSource quoteL285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3 |
| 2025 | IDEFICS+ADA-Steal proposed | Bert-S | 48.0 | fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100 | Medical Multimodal Model Stealing Attacks via Adversarial Domain AlignmentSource quoteL285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3 |
| 2025 | IDEFICS+ADA-Steal proposed | Rad-S | 14.1 | fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100 | Medical Multimodal Model Stealing Attacks via Adversarial Domain AlignmentSource quoteL285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.75 | split: test · fine-tuned · view=frontal · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL137: Frontal │ 0.75 │ 0.65 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.73 | split: test · fine-tuned · view=lateral · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL138: Lateral │ 0.73 │ 0.65 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.75 | split: test · fine-tuned · view=frontal+lateral ensemble · fusion=late · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL139: Ensemble │ 0.75 │ 0.69 \multirow{3}{*}{Contrastive} |
| 2025 | EMRRG proposed | F1 | 0.395 | fine-tuned | EMRRG: Efficient Fine-Tuning Pre-trained X-ray Mamba Networks for Radiology Report GenerationSource quoteL208: EMRRG │ Ours │ 0.421 │ 0.372 │ 0.395 |
| 2025 | XMedGPT with the clinical reasoning framework proposed | Kendall’s tau-b (consistency) | 0.479 | split: test · fine-tuned · training=SFT and DPO · annotation=Chest-Imagenome-derived regions | Multi-Modal Explainable Medical AI Assistant for Trustworthy Human-AI CollaborationSource quoteL82: Training on the MIMIC-CXR dataset involved supervised fine-tuning (SFT) with 10,000 samples for long chain-of-thought reasoning, followed by reinforcement learning via Direct Preference Optimization (DPO) on 8,201 high/low-scoring report pairs. Evaluation on a test set annotated with Chest-Imagenome-derived regions revealed a 6.05% average improvement across clinical metrics (CheXpert F1, Radgraph F1, CheXpert Similarity) compared to non-reasoning baselines. DPO further refined report quality, elevating CheXpert F1 from 0.362 to 0.372. The model’s reasoning coherence was quantitatively validated using Kendall’s tau-b correlation, which measured alignment between intermediate reasoning paths and final conclusions. Scores of 0.479 (consistency) and 0.474 (completeness; both P < 0.05) indicate strong logical agreement. |
| 2025 | BadMLLM proposed non-standard slice | ASR | 0.980 | fine-tuned · trigger=promotional phishing slogan · backbone=LLaVA-Med · target-disease=Pneumonia | Shadow-Activated Backdoor Attacks on Multimodal Large Language ModelsSource quoteL483: 0.980 |
| 2025 | BadMLLM proposed non-standard slice | ASR | 1.000 | fine-tuned · trigger=promotional phishing slogan · backbone=LLaVA-Med · target-disease=Pneumothorax | Shadow-Activated Backdoor Attacks on Multimodal Large Language ModelsSource quoteL485: 1.000 |
| 2025 | RadFM with V-RAG and no listed fine-tuning tasks ablation | F1 | 0.721 | fine-tuned | Reducing Hallucinations of Medical Multimodal Large Language Models with Visual Retrieval-Augmented GenerationSource quoteL336: 0.721 │ 0.920 |
| 2025 | LLaVA-Med + LoRA baseline | RaTEScore | 40.00 | split: test · fine-tuned · filter=very short reports excluded · subset=441 examples · tuning=LoRA · backbone=LLaVA-Med · report-sections=Findings and Impression | Focus on What Matters: Enhancing Medical Vision-Language Models with Automatic Attention Alignment TuningSource quoteL514: LLaVA-Med + LoRA │ 3.28 │ 16.54 │ 17.90 │ 85.57 │ 22.14 │ 9.43 │ 40.00 |
| 2025 | Supervised baseline (trained from scratch) baseline | macro-AUROC over 14 CheXpert labels | 0.69 | split: test · fine-tuned · view=frontal · labels=5,000 · training=from scratch | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL134: Frontal │ 0.69 |
| 2025 | Supervised baseline (trained from scratch) baseline | macro-AUROC over 14 CheXpert labels | 0.70 | split: test · fine-tuned · view=lateral · labels=5,000 · training=from scratch | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL135: Lateral │ 0.70 |
| 2025 | Supervised baseline (trained from scratch) baseline | macro-AUROC over 14 CheXpert labels | 0.70 | split: test · fine-tuned · view=frontal+lateral ensemble · fusion=late · labels=5,000 · training=from scratch | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL136: Ensemble │ 0.70 │ - \multirow{3}{*}{MVMAE} |
| 2025 | Regular-tune baseline non-standard slice | ASR | 0.976 | fine-tuned · backbone=LLaVA-Med · training=cross-entropy fine-tuning on polluted dataset · target-disease=Pneumonia | Shadow-Activated Backdoor Attacks on Multimodal Large Language ModelsSource quoteL478: 0.976 |
| 2025 | Regular-tune baseline non-standard slice | ASR | 0.967 | fine-tuned · backbone=LLaVA-Med · training=cross-entropy fine-tuning on polluted dataset · target-disease=Pneumothorax | Shadow-Activated Backdoor Attacks on Multimodal Large Language ModelsSource quoteL480: 0.967 |
| 2024 | Vicuna Key Prompt (protected) proposed | ROUGE-L | 35.13 | fine-tuned · key=provided · backbone=Vicuna · key-prompt-data=5% of original data · positive-to-negative-ratio=1:1 | Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language ModelsSource quoteL195: 35.13 |
| 2024 | Vicuna Key Prompt (protected, accessed without the key) proposed | ROUGE-L | 4.25 | fine-tuned · key=not provided · backbone=Vicuna | Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language ModelsSource quoteL202: 4.25 |
| 2024 | DiCoM proposed | AUPR | .947 | split: test · fine-tuned | DiCoM - Diverse Concept Modeling towards Enhancing Generalizability in Chest X-Ray StudiesSource quoteL214: DiCoM (ours) │ .865 │ .969 │ \multicolumn{1}{c|}{.852} │ .861 │ .987 │ .930 │ .843 │ {\ul .948} │ \multicolumn{1}{c|}{{\ul .802}} │ .840 │ .947 │ .807 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (INTER.) proposed | BL-1 | 0.364 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediate | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL750: 0.364 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (FINAL) proposed | BL-1 | 0.402 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=final | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL757: 0.402 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (INTER.) proposed | BL-4 | 0.093 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediate | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL753: 0.093 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (FINAL) proposed | BL-4 | 0.128 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=final | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL760: 0.128 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (INTER.) proposed | RG-L | 0.261 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediate | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL755: 0.261 |
| 2024 | MiniGPT-4 (FT)+I3+C2FD (FINAL) proposed | RG-L | 0.291 | split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=final | Bootstrapping Large Language Models for Radiology Report GenerationSource quoteL762: 0.291 |
| 2024 | Llama 3.1 Instruct-8B (9,000-sample joint training) proposed | micro-F1 | 0.67 | fine-tuned · params=8B · label-source=NegBio-derived · training-samples=9000 | Enhancing disease detection in radiology reports through fine-tuning lightweight LLM on weak labelsSource quoteL210: 9,000 │ 6,000 │ 3,000 │ 0.62 │ 0.72 │ 0.67 │ 0.44 │ 0.83 │ 0.58 |
| 2024 | Finetuned LLaMA-2 (gt conditions) baseline | BLEU-4 | 0.094 | fine-tuned · params=7B · section=impression · backbone=LLaMA-2-7B · condition-input=ground-truth conditions | GPT-4V Cannot Generate Radiology Reports YetSource quoteL880: LLaMA-2 (gt) │ \bf 0.301 │ \bf 0.094 │ \bf 0.330 │ \bf 0.348 │ \bf 0.923 │ 0.957 │ \bf 0.286 │ \bf 0.703 │ 0.941 │ 0.710 |
| 2024 | Vicuna Baseline (unprotected) baseline | ROUGE-L | 35.42 | fine-tuned · backbone=Vicuna | Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language ModelsSource quoteL188: 35.42 |
| 2024 | Full Tune baseline non-standard slice | Recall | 0.273 | split: test · fine-tuned · runs=3 · epochs=10 · training-subset=34,463 points · evaluation-labels=CheXpert | BiCAL: Bi-directional Contrastive Active Learning for Clinical Report GenerationSource quoteL213: 0.273 |
| 2024 | GPT-4o finetune baseline | CheXbert Micro-avg F1-14 | 48.9 | split: test · fine-tuned | MedImageInsight: An Open-Source Embedding Model for General Domain Medical ImagingSource quoteL187: GPT-4o finetune\tnote{d} │ 48.9 │ 52.7 │ 33.0 │ 43.8 │ 49.3 │ 54.7 │ 36.7 │ 47.8 │ 26.4 │ 29.3 │ 39.6 │ 17.8 │ 32.1 |
| 2024 | NegBio baseline | micro-F1 | 0.63 | fine-tuned · method-type=rule-based | Enhancing disease detection in radiology reports through fine-tuning lightweight LLM on weak labelsSource quoteL212: NegBio │ 0.82 │ 0.51 │ 0.63 |
| 2023 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposed | AUC | 79.53% | split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteL41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2023 | Proposed method (OURS; RadBloomz fine-tuned with detected-abnormality prompts) proposed | ROUGE-L | 0.373 | split: test · fine-tuned · prompt=detected abnormalities and probabilities · generation-length=128 tokens | Generation of Radiology Findings in Chest X-Ray by Leveraging Collaborative KnowledgeSource quoteL147: OURS │ 0.373 |
| 2023 | M-FLAG proposed | AUC | 69.5% | fine-tuned · labeled-data=1% | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteL112: M-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
| 2023 | Pragmatic LLaMA proposed | Pos F1 | 0.307 | split: test · fine-tuned · epochs=3 · section=impression · training-examples=18264 | Pragmatic Radiology Report GenerationSource quoteL383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158 |
| 2023 | Pragmatic LLaMA proposed | Neg F1-5 | 0.127 | split: test · fine-tuned · epochs=3 · section=impression · metric-subset=five most frequent negative labels · training-examples=18264 | Pragmatic Radiology Report GenerationSource quoteL383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158 |
| 2023 | Non-private fine-tuned NFNet-F0 (ImageNet-21K pre-trained) baseline | AUC | 81.14% | split: test · fine-tuned · privacy=non-private · backbone=NFNet-F0 · pretraining=ImageNet-21K | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteL41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2022 | Ours (baseline+MSA+MCGN) proposed | BLEU-4 | 0.120 | split: test · fine-tuned · beam-size=3 · reinforcement-learning=no | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299 |
| 2022 | Ours (baseline+MSA+MCGN) proposed | ROUGE-L | 0.143 | split: test · fine-tuned · beam-size=3 · reinforcement-learning=no | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299 |
| 2022 | Ours (baseline+MSA+MCGN) proposed | CIDEr | 0.299 | split: test · fine-tuned · beam-size=3 · reinforcement-learning=no | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299 |
| 2022 | Ours+RL proposed | BLEU-4 | 0.136 | split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr reward | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429 |
| 2022 | Ours+RL proposed | ROUGE-L | 0.170 | split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr reward | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429 |
| 2022 | Ours+RL proposed | CIDEr | 0.429 | split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr reward | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429 |
| 2022 | Unweighted and weighted bagging models proposed | AUC | 0.77 | split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weighted | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel. |
| 2022 | Unweighted and weighted bagging models proposed | F1-score | 0.54 | split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weighted | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel. |
| 2022 | Unweighted and weighted bagging models proposed | AUPRC | 0.56 | split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weighted | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel. |
| 2022 | Xception base model baseline | AUC | 0.76 | split: test · fine-tuned · split-unit=patient-level · pretraining-dataset=CheXpert | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL126: We present the results of four different state-of-the-art CNN models tested on MIMIC-CXR and Emory-CXR in Table~\ref{tab:Base models tested on MIMIC-IV data} and Table~\ref{tab:Base models tested on Emory data} of Appendix~\ref{appendix:Basemodel}. The Xception base model yields the best AUC score (0.76), F1-score (0.54), AUPRC (0.54), and balanced accuracy (0.69) during the internal testing on MIMIC-CXR; however, the performance of the four base models is relatively similar. Further, when performing external testing on Emory-CXR, the Xception base model attains the best performance. Additionally, the performance of the Xception base model on both MIMIC-CXR and Emory-CXR is very similar, demonstrating that our fine-tuned model does not overfit on the training data. The detailed results with precision and recall are listed in Supplementary Table B1 to B2. |
| 2022 | Xception base model baseline | F1-score | 0.54 | split: test · fine-tuned · split-unit=patient-level · pretraining-dataset=CheXpert | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL126: We present the results of four different state-of-the-art CNN models tested on MIMIC-CXR and Emory-CXR in Table~\ref{tab:Base models tested on MIMIC-IV data} and Table~\ref{tab:Base models tested on Emory data} of Appendix~\ref{appendix:Basemodel}. The Xception base model yields the best AUC score (0.76), F1-score (0.54), AUPRC (0.54), and balanced accuracy (0.69) during the internal testing on MIMIC-CXR; however, the performance of the four base models is relatively similar. Further, when performing external testing on Emory-CXR, the Xception base model attains the best performance. Additionally, the performance of the Xception base model on both MIMIC-CXR and Emory-CXR is very similar, demonstrating that our fine-tuned model does not overfit on the training data. The detailed results with precision and recall are listed in Supplementary Table B1 to B2. |
| 2022 | Xception base model baseline | AUPRC | 0.54 | split: test · fine-tuned · split-unit=patient-level · pretraining-dataset=CheXpert | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL126: We present the results of four different state-of-the-art CNN models tested on MIMIC-CXR and Emory-CXR in Table~\ref{tab:Base models tested on MIMIC-IV data} and Table~\ref{tab:Base models tested on Emory data} of Appendix~\ref{appendix:Basemodel}. The Xception base model yields the best AUC score (0.76), F1-score (0.54), AUPRC (0.54), and balanced accuracy (0.69) during the internal testing on MIMIC-CXR; however, the performance of the four base models is relatively similar. Further, when performing external testing on Emory-CXR, the Xception base model attains the best performance. Additionally, the performance of the Xception base model on both MIMIC-CXR and Emory-CXR is very similar, demonstrating that our fine-tuned model does not overfit on the training data. The detailed results with precision and recall are listed in Supplementary Table B1 to B2. |
| 2020 | Transformer re-implementation with Multi-View Dec. (GCA) proposed | CIDEr | 25.5 | fine-tuned · backbone=ResNet-50 · fine-tuning=CheXpert · pretraining=ImageNet · image-backbone=ResNet-50 | Rethinking and Improving Natural Language Generation with Layer-Wise Multi-View DecodingSource quoteL446: \ \ w/ Multi-View Dec. │ Ours │ \bf {37.1 (+3.7)}\ssymbol{3} │ \bf {23.2 (+2.5)}\ssymbol{3} │ \bf {15.7 (+1.6)}\ssymbol{3} │ \bf {11.0 (+0.8)}\ssymbol{3} │ \bf {15.4 (+1.9)}\ssymbol{3} │ \bf {29.3 (+2.2)}\ssymbol{3} │ \bf {25.5 (+5.9)}\ssymbol{3} |