MIMIC-CXR

263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

68.772.676.580.32024M-FLAG: 69.5 (2023)DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained): 79.53 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 60 of 60 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026AR-RRG proposedB-40.152split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedB-10.425split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedB-20.292split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedB-30.210split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026AR-RRG proposedRG-L0.322split: test · fine-tuned · params=7BAR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation
Source quote
L1266: RG-L, reaching 0.425, 0.292, 0.210, 0.152, and 0.322 for B-
2026LLaVA-TA proposedRadGraph F131.1fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · evaluation_setting=in-distributionRethinking Radiology Report Generation: From Narrative Flow to Topic-Guided Findings
Source quote
L601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs.
2026LLaVA-T ablationRadGraph F11.6fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · anatomical_masks=excluded · evaluation_setting=in-distributionRethinking Radiology Report Generation: From Narrative Flow to Topic-Guided Findings
Source quote
L601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs.
2025MoColl + tuned VQA model proposedROUGE-L0.2349fine-tunedMoColl: Agent-Based Specific and General Model Collaboration for Image Captioning
Source quote
L218: MoColl + tuned VQA model (Ours) │ \bf{0.2749} │ \bf{0.1454} │ \bf{0.0897} │ \bf{0.0655} │ \bf{0.1126} │ \bf{0.2349} │ \bf{0.0932}
2025MoColl + aligned VLM proposedROUGE-L0.1906fine-tunedMoColl: Agent-Based Specific and General Model Collaboration for Image Captioning
Source quote
L217: MoColl + aligned VLM (Ours) │ 0.2515 │ 0.1290 │ 0.0746 │ 0.0456 │ 0.0947 │ 0.1906 │ 0.0566
2025IDEFICS+ADA-Steal proposedRG-L21.4fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100Medical Multimodal Model Stealing Attacks via Adversarial Domain Alignment
Source quote
L285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3
2025IDEFICS+ADA-Steal proposedBert-S48.0fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100Medical Multimodal Model Stealing Attacks via Adversarial Domain Alignment
Source quote
L285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3
2025IDEFICS+ADA-Steal proposedRad-S14.1fine-tuned · epsilon=0.05 · attacker-image-distribution=CIFAR-100Medical Multimodal Model Stealing Attacks via Adversarial Domain Alignment
Source quote
L285: RG-L │ Bert-S │ Rad-S │ RG-L │ Bert-S │ Rad-S \emptyset │ 14.6 │ 8.0 │ 0.7 │ 14.1 │ 11.2 │ 0.3 CIFAR-100 │ 21.4 │ 48.0 │ 14.1 │ 27.6 │ 54.6 │ 22.3
2025MVMAE proposedmacro-AUROC over 14 CheXpert labels0.75split: test · fine-tuned · view=frontal · labels=5,000Leveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L137: Frontal │ 0.75 │ 0.65
2025MVMAE proposedmacro-AUROC over 14 CheXpert labels0.73split: test · fine-tuned · view=lateral · labels=5,000Leveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L138: Lateral │ 0.73 │ 0.65
2025MVMAE proposedmacro-AUROC over 14 CheXpert labels0.75split: test · fine-tuned · view=frontal+lateral ensemble · fusion=late · labels=5,000Leveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L139: Ensemble │ 0.75 │ 0.69 \multirow{3}{*}{Contrastive}
2025EMRRG proposedF10.395fine-tunedEMRRG: Efficient Fine-Tuning Pre-trained X-ray Mamba Networks for Radiology Report Generation
Source quote
L208: EMRRG │ Ours │ 0.421 │ 0.372 │ 0.395
2025XMedGPT with the clinical reasoning framework proposedKendall’s tau-b (consistency)0.479split: test · fine-tuned · training=SFT and DPO · annotation=Chest-Imagenome-derived regionsMulti-Modal Explainable Medical AI Assistant for Trustworthy Human-AI Collaboration
Source quote
L82: Training on the MIMIC-CXR dataset involved supervised fine-tuning (SFT) with 10,000 samples for long chain-of-thought reasoning, followed by reinforcement learning via Direct Preference Optimization (DPO) on 8,201 high/low-scoring report pairs. Evaluation on a test set annotated with Chest-Imagenome-derived regions revealed a 6.05% average improvement across clinical metrics (CheXpert F1, Radgraph F1, CheXpert Similarity) compared to non-reasoning baselines. DPO further refined report quality, elevating CheXpert F1 from 0.362 to 0.372. The model’s reasoning coherence was quantitatively validated using Kendall’s tau-b correlation, which measured alignment between intermediate reasoning paths and final conclusions. Scores of 0.479 (consistency) and 0.474 (completeness; both P < 0.05) indicate strong logical agreement.
2025BadMLLM proposed non-standard sliceASR0.980fine-tuned · trigger=promotional phishing slogan · backbone=LLaVA-Med · target-disease=PneumoniaShadow-Activated Backdoor Attacks on Multimodal Large Language Models
Source quote
L483: 0.980
2025BadMLLM proposed non-standard sliceASR1.000fine-tuned · trigger=promotional phishing slogan · backbone=LLaVA-Med · target-disease=PneumothoraxShadow-Activated Backdoor Attacks on Multimodal Large Language Models
Source quote
L485: 1.000
2025RadFM with V-RAG and no listed fine-tuning tasks ablationF10.721fine-tunedReducing Hallucinations of Medical Multimodal Large Language Models with Visual Retrieval-Augmented Generation
Source quote
L336: 0.721 │ 0.920
2025LLaVA-Med + LoRA baselineRaTEScore40.00split: test · fine-tuned · filter=very short reports excluded · subset=441 examples · tuning=LoRA · backbone=LLaVA-Med · report-sections=Findings and ImpressionFocus on What Matters: Enhancing Medical Vision-Language Models with Automatic Attention Alignment Tuning
Source quote
L514: LLaVA-Med + LoRA │ 3.28 │ 16.54 │ 17.90 │ 85.57 │ 22.14 │ 9.43 │ 40.00
2025Supervised baseline (trained from scratch) baselinemacro-AUROC over 14 CheXpert labels0.69split: test · fine-tuned · view=frontal · labels=5,000 · training=from scratchLeveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L134: Frontal │ 0.69
2025Supervised baseline (trained from scratch) baselinemacro-AUROC over 14 CheXpert labels0.70split: test · fine-tuned · view=lateral · labels=5,000 · training=from scratchLeveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L135: Lateral │ 0.70
2025Supervised baseline (trained from scratch) baselinemacro-AUROC over 14 CheXpert labels0.70split: test · fine-tuned · view=frontal+lateral ensemble · fusion=late · labels=5,000 · training=from scratchLeveraging the Structure of Medical Data for Improved Representation Learning
Source quote
L136: Ensemble │ 0.70 │ - \multirow{3}{*}{MVMAE}
2025Regular-tune baseline non-standard sliceASR0.976fine-tuned · backbone=LLaVA-Med · training=cross-entropy fine-tuning on polluted dataset · target-disease=PneumoniaShadow-Activated Backdoor Attacks on Multimodal Large Language Models
Source quote
L478: 0.976
2025Regular-tune baseline non-standard sliceASR0.967fine-tuned · backbone=LLaVA-Med · training=cross-entropy fine-tuning on polluted dataset · target-disease=PneumothoraxShadow-Activated Backdoor Attacks on Multimodal Large Language Models
Source quote
L480: 0.967
2024Vicuna Key Prompt (protected) proposedROUGE-L35.13fine-tuned · key=provided · backbone=Vicuna · key-prompt-data=5% of original data · positive-to-negative-ratio=1:1Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language Models
Source quote
L195: 35.13
2024Vicuna Key Prompt (protected, accessed without the key) proposedROUGE-L4.25fine-tuned · key=not provided · backbone=VicunaSecure Your Model: An Effective Key Prompt Protection Mechanism for Large Language Models
Source quote
L202: 4.25
2024DiCoM proposedAUPR.947split: test · fine-tunedDiCoM - Diverse Concept Modeling towards Enhancing Generalizability in Chest X-Ray Studies
Source quote
L214: DiCoM (ours) │ .865 │ .969 │ \multicolumn{1}{c|}{.852} │ .861 │ .987 │ .930 │ .843 │ {\ul .948} │ \multicolumn{1}{c|}{{\ul .802}} │ .840 │ .947 │ .807
2024MiniGPT-4 (FT)+I3+C2FD (INTER.) proposedBL-10.364split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediateBootstrapping Large Language Models for Radiology Report Generation
Source quote
L750: 0.364
2024MiniGPT-4 (FT)+I3+C2FD (FINAL) proposedBL-10.402split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=finalBootstrapping Large Language Models for Radiology Report Generation
Source quote
L757: 0.402
2024MiniGPT-4 (FT)+I3+C2FD (INTER.) proposedBL-40.093split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediateBootstrapping Large Language Models for Radiology Report Generation
Source quote
L753: 0.093
2024MiniGPT-4 (FT)+I3+C2FD (FINAL) proposedBL-40.128split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=finalBootstrapping Large Language Models for Radiology Report Generation
Source quote
L760: 0.128
2024MiniGPT-4 (FT)+I3+C2FD (INTER.) proposedRG-L0.261split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=intermediateBootstrapping Large Language Models for Radiology Report Generation
Source quote
L755: 0.261
2024MiniGPT-4 (FT)+I3+C2FD (FINAL) proposedRG-L0.291split: test · fine-tuned · backbone=MiniGPT-4 · report-stage=finalBootstrapping Large Language Models for Radiology Report Generation
Source quote
L762: 0.291
2024Llama 3.1 Instruct-8B (9,000-sample joint training) proposedmicro-F10.67fine-tuned · params=8B · label-source=NegBio-derived · training-samples=9000Enhancing disease detection in radiology reports through fine-tuning lightweight LLM on weak labels
Source quote
L210: 9,000 │ 6,000 │ 3,000 │ 0.62 │ 0.72 │ 0.67 │ 0.44 │ 0.83 │ 0.58
2024Finetuned LLaMA-2 (gt conditions) baselineBLEU-40.094fine-tuned · params=7B · section=impression · backbone=LLaMA-2-7B · condition-input=ground-truth conditionsGPT-4V Cannot Generate Radiology Reports Yet
Source quote
L880: LLaMA-2 (gt) │ \bf 0.301 │ \bf 0.094 │ \bf 0.330 │ \bf 0.348 │ \bf 0.923 │ 0.957 │ \bf 0.286 │ \bf 0.703 │ 0.941 │ 0.710
2024Vicuna Baseline (unprotected) baselineROUGE-L35.42fine-tuned · backbone=VicunaSecure Your Model: An Effective Key Prompt Protection Mechanism for Large Language Models
Source quote
L188: 35.42
2024Full Tune baseline non-standard sliceRecall0.273split: test · fine-tuned · runs=3 · epochs=10 · training-subset=34,463 points · evaluation-labels=CheXpertBiCAL: Bi-directional Contrastive Active Learning for Clinical Report Generation
Source quote
L213: 0.273
2024GPT-4o finetune baselineCheXbert Micro-avg F1-1448.9split: test · fine-tunedMedImageInsight: An Open-Source Embedding Model for General Domain Medical Imaging
Source quote
L187: GPT-4o finetune\tnote{d} │ 48.9 │ 52.7 │ 33.0 │ 43.8 │ 49.3 │ 54.7 │ 36.7 │ 47.8 │ 26.4 │ 29.3 │ 39.6 │ 17.8 │ 32.1
2024NegBio baselinemicro-F10.63fine-tuned · method-type=rule-basedEnhancing disease detection in radiology reports through fine-tuning lightweight LLM on weak labels
Source quote
L212: NegBio │ 0.82 │ 0.51 │ 0.63
2023DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposedAUC79.53%split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2023Proposed method (OURS; RadBloomz fine-tuned with detected-abnormality prompts) proposedROUGE-L0.373split: test · fine-tuned · prompt=detected abnormalities and probabilities · generation-length=128 tokensGeneration of Radiology Findings in Chest X-Ray by Leveraging Collaborative Knowledge
Source quote
L147: OURS │ 0.373
2023M-FLAG proposedAUC69.5%fine-tuned · labeled-data=1%M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry Optimization
Source quote
L112: M-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7
2023Pragmatic LLaMA proposedPos F10.307split: test · fine-tuned · epochs=3 · section=impression · training-examples=18264Pragmatic Radiology Report Generation
Source quote
L383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158
2023Pragmatic LLaMA proposedNeg F1-50.127split: test · fine-tuned · epochs=3 · section=impression · metric-subset=five most frequent negative labels · training-examples=18264Pragmatic Radiology Report Generation
Source quote
L383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158
2023Non-private fine-tuned NFNet-F0 (ImageNet-21K pre-trained) baselineAUC81.14%split: test · fine-tuned · privacy=non-private · backbone=NFNet-F0 · pretraining=ImageNet-21KUnlocking Accuracy and Fairness in Differentially Private Image Classification
Source quote
L41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR.
2022Ours (baseline+MSA+MCGN) proposedBLEU-40.120split: test · fine-tuned · beam-size=3 · reinforcement-learning=noA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299
2022Ours (baseline+MSA+MCGN) proposedROUGE-L0.143split: test · fine-tuned · beam-size=3 · reinforcement-learning=noA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299
2022Ours (baseline+MSA+MCGN) proposedCIDEr0.299split: test · fine-tuned · beam-size=3 · reinforcement-learning=noA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299
2022Ours+RL proposedBLEU-40.136split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr rewardA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429
2022Ours+RL proposedROUGE-L0.170split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr rewardA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429
2022Ours+RL proposedCIDEr0.429split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr rewardA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429
2022Unweighted and weighted bagging models proposedAUC0.77split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weightedEarly Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion Strategies
Source quote
L130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel.
2022Unweighted and weighted bagging models proposedF1-score0.54split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weightedEarly Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion Strategies
Source quote
L130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel.
2022Unweighted and weighted bagging models proposedAUPRC0.56split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weightedEarly Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion Strategies
Source quote
L130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel.
2022Xception base model baselineAUC0.76split: test · fine-tuned · split-unit=patient-level · pretraining-dataset=CheXpertEarly Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion Strategies
Source quote
L126: We present the results of four different state-of-the-art CNN models tested on MIMIC-CXR and Emory-CXR in Table~\ref{tab:Base models tested on MIMIC-IV data} and Table~\ref{tab:Base models tested on Emory data} of Appendix~\ref{appendix:Basemodel}. The Xception base model yields the best AUC score (0.76), F1-score (0.54), AUPRC (0.54), and balanced accuracy (0.69) during the internal testing on MIMIC-CXR; however, the performance of the four base models is relatively similar. Further, when performing external testing on Emory-CXR, the Xception base model attains the best performance. Additionally, the performance of the Xception base model on both MIMIC-CXR and Emory-CXR is very similar, demonstrating that our fine-tuned model does not overfit on the training data. The detailed results with precision and recall are listed in Supplementary Table B1 to B2.
2022Xception base model baselineF1-score0.54split: test · fine-tuned · split-unit=patient-level · pretraining-dataset=CheXpertEarly Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion Strategies
Source quote
L126: We present the results of four different state-of-the-art CNN models tested on MIMIC-CXR and Emory-CXR in Table~\ref{tab:Base models tested on MIMIC-IV data} and Table~\ref{tab:Base models tested on Emory data} of Appendix~\ref{appendix:Basemodel}. The Xception base model yields the best AUC score (0.76), F1-score (0.54), AUPRC (0.54), and balanced accuracy (0.69) during the internal testing on MIMIC-CXR; however, the performance of the four base models is relatively similar. Further, when performing external testing on Emory-CXR, the Xception base model attains the best performance. Additionally, the performance of the Xception base model on both MIMIC-CXR and Emory-CXR is very similar, demonstrating that our fine-tuned model does not overfit on the training data. The detailed results with precision and recall are listed in Supplementary Table B1 to B2.
2022Xception base model baselineAUPRC0.54split: test · fine-tuned · split-unit=patient-level · pretraining-dataset=CheXpertEarly Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion Strategies
Source quote
L126: We present the results of four different state-of-the-art CNN models tested on MIMIC-CXR and Emory-CXR in Table~\ref{tab:Base models tested on MIMIC-IV data} and Table~\ref{tab:Base models tested on Emory data} of Appendix~\ref{appendix:Basemodel}. The Xception base model yields the best AUC score (0.76), F1-score (0.54), AUPRC (0.54), and balanced accuracy (0.69) during the internal testing on MIMIC-CXR; however, the performance of the four base models is relatively similar. Further, when performing external testing on Emory-CXR, the Xception base model attains the best performance. Additionally, the performance of the Xception base model on both MIMIC-CXR and Emory-CXR is very similar, demonstrating that our fine-tuned model does not overfit on the training data. The detailed results with precision and recall are listed in Supplementary Table B1 to B2.
2020Transformer re-implementation with Multi-View Dec. (GCA) proposedCIDEr25.5fine-tuned · backbone=ResNet-50 · fine-tuning=CheXpert · pretraining=ImageNet · image-backbone=ResNet-50Rethinking and Improving Natural Language Generation with Layer-Wise Multi-View Decoding
Source quote
L446: \ \ w/ Multi-View Dec. │ Ours │ \bf {37.1 (+3.7)}\ssymbol{3} │ \bf {23.2 (+2.5)}\ssymbol{3} │ \bf {15.7 (+1.6)}\ssymbol{3} │ \bf {11.0 (+0.8)}\ssymbol{3} │ \bf {15.4 (+1.9)}\ssymbol{3} │ \bf {29.3 (+2.2)}\ssymbol{3} │ \bf {25.5 (+5.9)}\ssymbol{3}