MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 40 of 40 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | RIHA (Report-Image Hierarchical Alignment Transformer) proposed | ROUGE-L | 0.293 | Reported benchmark result for RIHA on MIMIC-CXR; the split is not specified in the cite… | RIHA: Report-Image Hierarchical Alignment for Radiology Report GenerationSource quoteL146: On the more challenging MIMIC-CXR dataset, RIHA demonstrates competitive results, achieving the best scores in BLEU-1 (0.385), BLEU-2 (0.251), METEOR (0.159), and ROUGE-L (0.293). Our method shows consistent improvements over recent approaches including M2KT~\cite{yang2023radiology} (4.6% improvement on BLEU-1), CAMANET~\cite{wang2024camanet} (4.9% improvement on BLEU-1), and COMG~\cite{gu2024complex} (11.6% improvement on BLEU-1). |
| 2025 | MoColl + tuned VQA model proposed | ROUGE-L | 0.2349 | fine-tuned | MoColl: Agent-Based Specific and General Model Collaboration for Image CaptioningSource quoteL218: MoColl + tuned VQA model (Ours) │ \bf{0.2749} │ \bf{0.1454} │ \bf{0.0897} │ \bf{0.0655} │ \bf{0.1126} │ \bf{0.2349} │ \bf{0.0932} |
| 2025 | MoColl + aligned VLM proposed | ROUGE-L | 0.1906 | fine-tuned | MoColl: Agent-Based Specific and General Model Collaboration for Image CaptioningSource quoteL217: MoColl + aligned VLM (Ours) │ 0.2515 │ 0.1290 │ 0.0746 │ 0.0456 │ 0.0947 │ 0.1906 │ 0.0566 |
| 2025 | MedUnifier (w TIG) proposed | ROUGE-L (RG-L) | 34.0 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MCA-RG (7B; listed as Ours) proposed | ROUGE-L (RG-L) | 0.300 | params=7B | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL138: Ours │ 7B │ 0.411 │ 0.256 │ 0.175 │ 0.128 │ 0.163 │ 0.300 |
| 2025 | OTDRG proposed | ROUGE-L | 0.295 | Report-generation comparison table; table states results are from the original papers. | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | RRG-opt proposed | ROUGEL | 0.239 | subset=3.70% | CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest RadiographsSource quoteL168: RRG-opt (ours) │ 3.70% │ 0.241 │ 0.157 │ 0.108 │ 0.078 │ 0.109 │ 0.239 │ 0.513 |
| 2025 | HTSC-CIF proposed | ROUGE-L | 0.305 | split: test | Medical Report Generation: A Hierarchical Task Structure-Based Cross-Modal Causal Intervention FrameworkSource quoteL230: Ours │ 0.413 │ 0.264 │ 0.193 │ 0.139 │ 0.177 │ 0.305 │ 0.386 |
| 2025 | Disease-Aware Dual-Stage Framework (Ours; DASTs + DVAF + DMSR) proposed | ROUGE-L | 0.291 | stage-1-data=480,000 image-text pairs · stage-1-supervision=14-category CheXpert labels | A Disease-Aware Dual-Stage Framework for Chest X-ray Report GenerationSource quoteL231: Ours │ -- │ 0.428 │ 0.272 │ 0.187 │ 0.131 │ 0.291 │ 0.232 |
| 2024 | FITA proposed | ROUGE-L | 0.295 | split: test | FITA: Fine-grained Image-Text Aligner for Radiology Report GenerationSource quoteL107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326 |
| 2024 | Vicuna Key Prompt (protected) proposed | ROUGE-L | 35.13 | fine-tuned · key=provided · backbone=Vicuna · key-prompt-data=5% of original data · positive-to-negative-ratio=1:1 | Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language ModelsSource quoteL195: 35.13 |
| 2024 | Vicuna Key Prompt (protected, accessed without the key) proposed | ROUGE-L | 4.25 | fine-tuned · key=not provided · backbone=Vicuna | Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language ModelsSource quoteL202: 4.25 |
| 2024 | TRRG full configuration (BASE + DCI + CMCI + DAL) proposed | ROUGE | 0.336 | Full ablation configuration: DCI, CMCI, and DAL added to BASE; split not specified in t… | TRRG: Towards Truthful Radiology Report Generation With Cross-modal Disease Clue Enhanced Large Language ModelSource quoteL248: 4 │ \multicolumn{1}{l|}{+DCI+CMCI+DAL} │ 0.151 │ 0.377 │ 0.209 │ 0.405 │ 0.157 │ 0.336 │ 0.167 │ 0.219 │ 0.393 |
| 2024 | Ours (pathology-aware regional prompts; PARP) proposed | ROUGE-L | 0.302 | Automated natural language generation metric; compared with state-of-the-art report-gen… | Anatomy-Guided Radiology Report Generation with Pathology-Aware Regional PromptsSource quoteL393: 0.302 |
| 2024 | R2GenCSR (Llama2 text decoder) proposed | ROUGE-L | 0.291 | decoder=Llama2 | R2GenCSR: Retrieving Context Samples for Large Language Model based X-ray Medical Report GenerationSource quoteL345: As shown in Table~\ref{tab:results_iu_mimic}, we report our results on the large-scale MIMIC-CXR dataset. Our method achieved a BLEU-1 score of 0.420, a BLEU-4 score of 0.136, and a ROUGE-L score of 0.291, indicating its ability to generate precise and contextually relevant medical reports. The CIDEr score of 0.267 suggests that the method produces descriptive reports that closely match the reference summaries, highlighting its practical application in clinical settings. Note that our approach employs a dataset-specific strategy, utilizing Llama2 as the text decoder, which is the model variant optimized for the MIMIC-CXR dataset, ensuring that the model is well-suited to the medical reports it processes. Notably, as illustrated in Table~\ref{tab:Clinical_Efficacy_Metrics}, our method achieves competitive CE scores for the MIMIC-CXR dataset, highlighting the robustness of our model in handling imbalanced datasets by effectively capturing relationships in both major and minor categories. |
| 2024 | LM-RRG proposed | ROUGE | 0.296 | Main comparison table; NLG metric. Split not stated. | Large Model driven Radiology Report Generation with Clinical Quality Reinforcement LearningSource quoteL193: LM-RRG(Ours) │ 0.122 │ 0.165 │ 0.296 │ 0.500 │ 0.500 │ 0.484 │ 0.865 |
| 2024 | CoFE proposed | ROUGE-L | 0.304 | Descriptive-accuracy report-generation evaluation on MIMIC-CXR, as reported in the NLG … | Contrastive Learning with Counterfactual Explanations for Radiology Report GenerationSource quoteL152: CoFE │ 0.731 │ 0.175 │ 0.438 │ 0.202 │ CoFE │ 0.453 │ 0.125 │ 0.304 │ 0.176 |
| 2024 | RadFound | ROUGE-L | 0.306 | Radiological report generation; reports include findings and impression sections and ar… | Expert-level vision-language foundation model for real-world radiology and comprehensive evaluationSource quoteL74: Radiological report benchmarks typically feature longer text lengths and contain more professional and detailed descriptions. Here, RadFound was evaluated for its synthesis skills in generating radiological text. On the IU-Xray dataset, RadFound achieved ROUGE-L and BLEU-4 scores of 0.357 and 0.186 respectively, while the baseline model achieved 0.294 and 0.125. On the MIMIC-CXR dataset, RadFound achieved ROUGE-L of 0.306 and BLEU-4 of 0.114, outperforming the baseline model, which obtained noticeably lower scores of 0.219 and 0.050, respectively (Fig. 3d). The excellent performance indicates that RadFound has developed proficient text generation capabilities, including the generation of longer and more complex radiological reports. Additionally, on the MIMIC-CXR dataset, we evaluated the clinical efficacy26, which measures the accuracy of descriptions for clinical abnormalities across diseases, such as pneumonia and edema (Supplementary Figure |
| 2024 | KiUT baseline | ROUGE-L | 0.285 | split: test | FITA: Fine-grained Image-Text Aligner for Radiology Report GenerationSource quoteL105: KiUT~\cite{huang2023kiut} │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321 |
| 2024 | Vicuna Baseline (unprotected) baseline | ROUGE-L | 35.42 | fine-tuned · backbone=Vicuna | Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language ModelsSource quoteL188: 35.42 |
| 2024 | RECAP baseline | ROUGE | 28.8% | Report generation; MIMIC-CXR evaluation. | Has multimodal learning delivered universal intelligence in healthcare? A comprehensive surveySource quoteL833: However, these models are still constrained by the data bias inherent in current datasets, which impairs their ability to detect and accurately describe subtle anomalies. On the MIMIC-ABN dataset~\cite{ni-etal-2020-learning}, which exclusively contains anomaly descriptions from the MIMIC-CXR dataset, the performance of these models on various metrics is significantly degraded~\cite{ni-etal-2020-learning, DBLP:conf/emnlp/HouCXLL23}. For instance, the BLEU-4 and ROUGE scores of RECAP~\cite{DBLP:conf/emnlp/HouCXLL23} on MIMIC-CXR are 12.5% and 28.8%, respectively, while on MIMIC-ABN, they drop to 8% and 22.3%, respectively. Furthermore, these models often overlook individual variability and the influence of patient-specific clinical context on diagnostic conclusions. This lack of consideration for personalized clinical information limits the overall effectiveness and accuracy of the generated reports. |
| 2024 | Gemini-1.0-Pro-Vision baseline | R-1 (ROUGE) | 0.2814 | 0-shot | Potential of Multimodal Large Language Models for Data Mining of Medical Images and Free-text ReportsSource quoteL276: Gemini-1.0-Pro-Vision │ 0.2814 │ 0.1334 │ 0.2259 │ 0.1654 │ 0.0663 │ 0.1425 │ 0.0103 │ 0.0000 │ 0.0087 |
| 2024 | Gemini-1.0-Pro-Vision baseline | R-L (ROUGE) | 0.2259 | 0-shot | Potential of Multimodal Large Language Models for Data Mining of Medical Images and Free-text ReportsSource quoteL276: Gemini-1.0-Pro-Vision │ 0.2814 │ 0.1334 │ 0.2259 │ 0.1654 │ 0.0663 │ 0.1425 │ 0.0103 │ 0.0000 │ 0.0087 |
| 2024 | Nguyen et al. clinical-document-guided model baseline | ROUGE-L (RG-L) | 0.390 | The review reports this as a highest NLP score; clinical documents, such as patient his… | Automatic Medical Report Generation: Methods and ApplicationsSource quoteL403: Human-computer interaction technology achieves the highest scores in both NLP and CE. Specifically, the inclusion of doctors' notes significantly enhances the quality of the generated reports. Nguyen et al. \cite{nguyen2021automated} achieved the best NLP scores on both MIMIC-CXR (BL-4: 0.224, MTR: 0.222, and RG-L: 0.390) and IU-Xray (BL-4: 0.235, MTR: 0.219, and RG-L: 0.436) by incorporating clinical documents. These clinical documents, which may include patients’ clinical histories or doctors’ notes, guide the model to focus on specific areas of the image and relevant diseases. For instance, if the doctor's note mentions ``shows cough and shortness of breath symptoms'', the model will focus on the lung area and consider pneumonia. In addition to human-computer interaction, the model involves disease classification, memory retrieval and traceback mechanism, as illustrated in Figure \ref{human}. Similarly, Liu et al. \cite{liu2023observation} introduced disease labels provided by radiologists, achieving the highest CE scores (P: 0.855, R: 0.730, and F: 0.773). Their model offers two options: automatic disease classification based on the input image or radiologist-provided potential disease labels. The latter results in markedly higher clinical efficacy in generated reports. Thus, incorporating human guidance into the model effectively improves the quality of the generated reports. |
| 2023 | Proposed method (OURS; RadBloomz fine-tuned with detected-abnormality prompts) proposed | ROUGE-L | 0.373 | split: test · fine-tuned · prompt=detected abnormalities and probabilities · generation-length=128 tokens | Generation of Radiology Findings in Chest X-Ray by Leveraging Collaborative KnowledgeSource quoteL147: OURS │ 0.373 |
| 2023 | CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposed | ROUGE-L | 47.75 | split: test · evaluation=RadSum23 public test | KU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report SummarizationSource quoteL148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96 |
| 2023 | CLIP with X-TRA retrieval augmentation proposed | ROUGE-L | .339 | model=CLIP · backbone=CLIP · augmentation=X-TRA retrieval augmentation | X-TRA: Improving Chest X-ray Tasks with Cross-Modal Retrieval AugmentationSource quoteL178: CLIP │ .318~(\uparrow.041) │ .226~(\uparrow.041) │ .121~(\uparrow.024) │ .085~(\uparrow.023) │ .339~(\uparrow.044) │ \textBF{.296~(\uparrow.055)} │ \textBF{.617(\uparrow.31)} |
| 2023 | C^2M-DoT proposed | ROUGE-L | 0.3850 | split: test | C^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer networkSource quoteL275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850 |
| 2023 | Radiology-Llama2 proposed | Rouge-1 | 0.4834 | Radiology impressions generated from findings; dataset-level ROUGE evaluation. No furth… | Radiology-Llama2: Best-in-Class Large Language Model for RadiologySource quoteL137: Radiology-Llama2 │ 0.4834 │ 0.324 │ 0.4427 │ 0.4185 │ 0.2569 │ 0.4087 |
| 2023 | Radiology-Llama2 proposed | Rouge-2 | 0.324 | Radiology impressions generated from findings; dataset-level ROUGE evaluation. No furth… | Radiology-Llama2: Best-in-Class Large Language Model for RadiologySource quoteL137: Radiology-Llama2 │ 0.4834 │ 0.324 │ 0.4427 │ 0.4185 │ 0.2569 │ 0.4087 |
| 2023 | Radiology-Llama2 proposed | Rouge-L | 0.4427 | Radiology impressions generated from findings; dataset-level ROUGE evaluation. No furth… | Radiology-Llama2: Best-in-Class Large Language Model for RadiologySource quoteL137: Radiology-Llama2 │ 0.4834 │ 0.324 │ 0.4427 │ 0.4185 │ 0.2569 │ 0.4087 |
| 2023 | DCL (row “Ours”) proposed | ROUGE-L | 0.284 | split: test | Dynamic Graph Enhanced Contrastive Learning for Chest X-ray Report GenerationSource quoteL188: Ours │ 0.586 │ 0.163 │ 0.383 │ 0.193 │ Ours │ 0.281 │ 0.109 │ 0.284 │ 0.150 |
| 2023 | REMOTE (100% labeled training data) proposed | ROUGE-L | 0.304 | split: test · labeled-training-data=100% | A Self-training Framework for Automated Medical Report GenerationSource quoteL322: The results in Table 1 show the comparison of REMOTE and existing strong methods, e.g., PPKED (Liu et al., 2021b), DeltaNet (Wu et al., 2022), and XProNet (Wang et al., 2022a). As we can see, when trained on 1% of labeled image-report pairs, combined with 90% of image-only data without reports, REMOTE demonstrates competitive performance with previous methods. When REMOTE is trained with the complete 100% labeled data, its performance surpasses the existing stateof-the-art methods on both two datasets. For example, on the MIMIC-CXR dataset, REMOTE achieves a BLEU-4 score of 0.125, a METEOR score of 0.157, a ROUGE-L score of 0.304, and a |
| 2023 | PhenotypeCLIP proposed | ROUGE-L | 0.286 | split: test · beam-size=3 | Fine-grained Medical Vision-Language Representation Learning for Radiology Report GenerationSource quoteL238: BLEU-4 (0.119/0.205), METEOR (0.158/0.223), and ROUGE-L (0.286/0.414) scores, surpassing all other methods. In particular, our PhenotypeCLIP consistently outperformed all previous conventional contrastive learning methods across all evaluation metrics. For example, the PhenotypeCLIP outperforms previous contrastive learning models |
| 2023 | Li et al. (report generation) baseline | ROUGE-L | .415 | method=Li et al. (2022) | X-TRA: Improving Chest X-ray Tasks with Cross-Modal Retrieval AugmentationSource quoteL172: Li et al.~\cite{li2022self} │ \textBF{.467} │ \textBF{.334} │ \textBF{.261} │ \textBF{.215} │ \textBF{.415} │ .201 │ -\\\multirow{5}{*}{\begin{tabular}[c]{@{}l@{}}Report retrieval} │ Chambon et al.~\cite{chambon2022roentgen} │ .432 |
| 2023 | HReMRG-MR baseline | ROUGE-L | 0.3742 | Main-results report-generation comparison; baselines were re-implemented. Averaging is … | C^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer networkSource quoteL273: HReMRG-MR │ 0.4696 │ 0.3251 │ 0.2412 │ 0.1877 │ 0.1993 │ 0.3742 |
| 2022 | Ours (baseline+MSA+MCGN) proposed | ROUGE-L | 0.143 | split: test · fine-tuned · beam-size=3 · reinforcement-learning=no | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299 |
| 2022 | Ours+RL proposed | ROUGE-L | 0.170 | split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr reward | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429 |
| 2021 | T5-base, run 7 (findings-only) | Rouge 2 | 46.5 | split: val | Optum at MEDIQA 2021: Abstractive Summarization of Radiology Reports using simple BART FinetuningSource quoteL127: 46.5 |
| 2021 | T5-base, run 8 (background and findings) | Rouge 2 | 51.22 | split: val | Optum at MEDIQA 2021: Abstractive Summarization of Radiology Reports using simple BART FinetuningSource quoteL131: 51.22 |