MIMIC-CXR

263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

68.772.676.580.32024M-FLAG: 69.5 (2023)DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained): 79.53 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 29 of 29 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026RIHA (Report-Image Hierarchical Alignment Transformer) proposedROUGE-L0.293Reported benchmark result for RIHA on MIMIC-CXR; the split is not specified in the cite…RIHA: Report-Image Hierarchical Alignment for Radiology Report Generation
Source quote
L146: On the more challenging MIMIC-CXR dataset, RIHA demonstrates competitive results, achieving the best scores in BLEU-1 (0.385), BLEU-2 (0.251), METEOR (0.159), and ROUGE-L (0.293). Our method shows consistent improvements over recent approaches including M2KT~\cite{yang2023radiology} (4.6% improvement on BLEU-1), CAMANET~\cite{wang2024camanet} (4.9% improvement on BLEU-1), and COMG~\cite{gu2024complex} (11.6% improvement on BLEU-1).
2025MoColl + tuned VQA model proposedROUGE-L0.2349fine-tunedMoColl: Agent-Based Specific and General Model Collaboration for Image Captioning
Source quote
L218: MoColl + tuned VQA model (Ours) │ \bf{0.2749} │ \bf{0.1454} │ \bf{0.0897} │ \bf{0.0655} │ \bf{0.1126} │ \bf{0.2349} │ \bf{0.0932}
2025MoColl + aligned VLM proposedROUGE-L0.1906fine-tunedMoColl: Agent-Based Specific and General Model Collaboration for Image Captioning
Source quote
L217: MoColl + aligned VLM (Ours) │ 0.2515 │ 0.1290 │ 0.0746 │ 0.0456 │ 0.0947 │ 0.1906 │ 0.0566
2025MedUnifier (w TIG) proposedROUGE-L (RG-L)34.0split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MCA-RG (7B; listed as Ours) proposedROUGE-L (RG-L)0.300params=7BMCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report Generation
Source quote
L138: Ours │ 7B │ 0.411 │ 0.256 │ 0.175 │ 0.128 │ 0.163 │ 0.300
2025OTDRG proposedROUGE-L0.295Report-generation comparison table; table states results are from the original papers.Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMs
Source quote
L277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295
2025RRG-opt proposedROUGEL0.239subset=3.70%CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest Radiographs
Source quote
L168: RRG-opt (ours) │ 3.70% │ 0.241 │ 0.157 │ 0.108 │ 0.078 │ 0.109 │ 0.239 │ 0.513
2025HTSC-CIF proposedROUGE-L0.305split: testMedical Report Generation: A Hierarchical Task Structure-Based Cross-Modal Causal Intervention Framework
Source quote
L230: Ours │ 0.413 │ 0.264 │ 0.193 │ 0.139 │ 0.177 │ 0.305 │ 0.386
2025Disease-Aware Dual-Stage Framework (Ours; DASTs + DVAF + DMSR) proposedROUGE-L0.291stage-1-data=480,000 image-text pairs · stage-1-supervision=14-category CheXpert labelsA Disease-Aware Dual-Stage Framework for Chest X-ray Report Generation
Source quote
L231: Ours │ -- │ 0.428 │ 0.272 │ 0.187 │ 0.131 │ 0.291 │ 0.232
2024FITA proposedROUGE-L0.295split: testFITA: Fine-grained Image-Text Aligner for Radiology Report Generation
Source quote
L107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326
2024Vicuna Key Prompt (protected) proposedROUGE-L35.13fine-tuned · key=provided · backbone=Vicuna · key-prompt-data=5% of original data · positive-to-negative-ratio=1:1Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language Models
Source quote
L195: 35.13
2024Vicuna Key Prompt (protected, accessed without the key) proposedROUGE-L4.25fine-tuned · key=not provided · backbone=VicunaSecure Your Model: An Effective Key Prompt Protection Mechanism for Large Language Models
Source quote
L202: 4.25
2024TRRG full configuration (BASE + DCI + CMCI + DAL) proposedROUGE0.336Full ablation configuration: DCI, CMCI, and DAL added to BASE; split not specified in t…TRRG: Towards Truthful Radiology Report Generation With Cross-modal Disease Clue Enhanced Large Language Model
Source quote
L248: 4 │ \multicolumn{1}{l|}{+DCI+CMCI+DAL} │ 0.151 │ 0.377 │ 0.209 │ 0.405 │ 0.157 │ 0.336 │ 0.167 │ 0.219 │ 0.393
2024Ours (pathology-aware regional prompts; PARP) proposedROUGE-L0.302Automated natural language generation metric; compared with state-of-the-art report-gen…Anatomy-Guided Radiology Report Generation with Pathology-Aware Regional Prompts
Source quote
L393: 0.302
2024R2GenCSR (Llama2 text decoder) proposedROUGE-L0.291decoder=Llama2R2GenCSR: Retrieving Context Samples for Large Language Model based X-ray Medical Report Generation
Source quote
L345: As shown in Table~\ref{tab:results_iu_mimic}, we report our results on the large-scale MIMIC-CXR dataset. Our method achieved a BLEU-1 score of 0.420, a BLEU-4 score of 0.136, and a ROUGE-L score of 0.291, indicating its ability to generate precise and contextually relevant medical reports. The CIDEr score of 0.267 suggests that the method produces descriptive reports that closely match the reference summaries, highlighting its practical application in clinical settings. Note that our approach employs a dataset-specific strategy, utilizing Llama2 as the text decoder, which is the model variant optimized for the MIMIC-CXR dataset, ensuring that the model is well-suited to the medical reports it processes. Notably, as illustrated in Table~\ref{tab:Clinical_Efficacy_Metrics}, our method achieves competitive CE scores for the MIMIC-CXR dataset, highlighting the robustness of our model in handling imbalanced datasets by effectively capturing relationships in both major and minor categories.
2024LM-RRG proposedROUGE0.296Main comparison table; NLG metric. Split not stated.Large Model driven Radiology Report Generation with Clinical Quality Reinforcement Learning
Source quote
L193: LM-RRG(Ours) │ 0.122 │ 0.165 │ 0.296 │ 0.500 │ 0.500 │ 0.484 │ 0.865
2024CoFE proposedROUGE-L0.304Descriptive-accuracy report-generation evaluation on MIMIC-CXR, as reported in the NLG …Contrastive Learning with Counterfactual Explanations for Radiology Report Generation
Source quote
L152: CoFE │ 0.731 │ 0.175 │ 0.438 │ 0.202 │ CoFE │ 0.453 │ 0.125 │ 0.304 │ 0.176
2023Proposed method (OURS; RadBloomz fine-tuned with detected-abnormality prompts) proposedROUGE-L0.373split: test · fine-tuned · prompt=detected abnormalities and probabilities · generation-length=128 tokensGeneration of Radiology Findings in Chest X-Ray by Leveraging Collaborative Knowledge
Source quote
L147: OURS │ 0.373
2023CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposedROUGE-L47.75split: test · evaluation=RadSum23 public testKU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report Summarization
Source quote
L148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96
2023CLIP with X-TRA retrieval augmentation proposedROUGE-L.339model=CLIP · backbone=CLIP · augmentation=X-TRA retrieval augmentationX-TRA: Improving Chest X-ray Tasks with Cross-Modal Retrieval Augmentation
Source quote
L178: CLIP │ .318~(\uparrow.041) │ .226~(\uparrow.041) │ .121~(\uparrow.024) │ .085~(\uparrow.023) │ .339~(\uparrow.044) │ \textBF{.296~(\uparrow.055)} │ \textBF{.617(\uparrow.31)}
2023C^2M-DoT proposedROUGE-L0.3850split: testC^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer network
Source quote
L275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850
2023Radiology-Llama2 proposedRouge-10.4834Radiology impressions generated from findings; dataset-level ROUGE evaluation. No furth…Radiology-Llama2: Best-in-Class Large Language Model for Radiology
Source quote
L137: Radiology-Llama2 │ 0.4834 │ 0.324 │ 0.4427 │ 0.4185 │ 0.2569 │ 0.4087
2023Radiology-Llama2 proposedRouge-20.324Radiology impressions generated from findings; dataset-level ROUGE evaluation. No furth…Radiology-Llama2: Best-in-Class Large Language Model for Radiology
Source quote
L137: Radiology-Llama2 │ 0.4834 │ 0.324 │ 0.4427 │ 0.4185 │ 0.2569 │ 0.4087
2023Radiology-Llama2 proposedRouge-L0.4427Radiology impressions generated from findings; dataset-level ROUGE evaluation. No furth…Radiology-Llama2: Best-in-Class Large Language Model for Radiology
Source quote
L137: Radiology-Llama2 │ 0.4834 │ 0.324 │ 0.4427 │ 0.4185 │ 0.2569 │ 0.4087
2023DCL (row “Ours”) proposedROUGE-L0.284split: testDynamic Graph Enhanced Contrastive Learning for Chest X-ray Report Generation
Source quote
L188: Ours │ 0.586 │ 0.163 │ 0.383 │ 0.193 │ Ours │ 0.281 │ 0.109 │ 0.284 │ 0.150
2023REMOTE (100% labeled training data) proposedROUGE-L0.304split: test · labeled-training-data=100%A Self-training Framework for Automated Medical Report Generation
Source quote
L322: The results in Table 1 show the comparison of REMOTE and existing strong methods, e.g., PPKED (Liu et al., 2021b), DeltaNet (Wu et al., 2022), and XProNet (Wang et al., 2022a). As we can see, when trained on 1% of labeled image-report pairs, combined with 90% of image-only data without reports, REMOTE demonstrates competitive performance with previous methods. When REMOTE is trained with the complete 100% labeled data, its performance surpasses the existing stateof-the-art methods on both two datasets. For example, on the MIMIC-CXR dataset, REMOTE achieves a BLEU-4 score of 0.125, a METEOR score of 0.157, a ROUGE-L score of 0.304, and a
2023PhenotypeCLIP proposedROUGE-L0.286split: test · beam-size=3Fine-grained Medical Vision-Language Representation Learning for Radiology Report Generation
Source quote
L238: BLEU-4 (0.119/0.205), METEOR (0.158/0.223), and ROUGE-L (0.286/0.414) scores, surpassing all other methods. In particular, our PhenotypeCLIP consistently outperformed all previous conventional contrastive learning methods across all evaluation metrics. For example, the PhenotypeCLIP outperforms previous contrastive learning models
2022Ours (baseline+MSA+MCGN) proposedROUGE-L0.143split: test · fine-tuned · beam-size=3 · reinforcement-learning=noA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299
2022Ours+RL proposedROUGE-L0.170split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr rewardA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429