MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 8 of 8 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | MoColl + tuned VQA model proposed | ROUGE-L | 0.2349 | fine-tuned | MoColl: Agent-Based Specific and General Model Collaboration for Image CaptioningSource quoteL218: MoColl + tuned VQA model (Ours) │ \bf{0.2749} │ \bf{0.1454} │ \bf{0.0897} │ \bf{0.0655} │ \bf{0.1126} │ \bf{0.2349} │ \bf{0.0932} |
| 2025 | MoColl + aligned VLM proposed | ROUGE-L | 0.1906 | fine-tuned | MoColl: Agent-Based Specific and General Model Collaboration for Image CaptioningSource quoteL217: MoColl + aligned VLM (Ours) │ 0.2515 │ 0.1290 │ 0.0746 │ 0.0456 │ 0.0947 │ 0.1906 │ 0.0566 |
| 2024 | Vicuna Key Prompt (protected) proposed | ROUGE-L | 35.13 | fine-tuned · key=provided · backbone=Vicuna · key-prompt-data=5% of original data · positive-to-negative-ratio=1:1 | Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language ModelsSource quoteL195: 35.13 |
| 2024 | Vicuna Key Prompt (protected, accessed without the key) proposed | ROUGE-L | 4.25 | fine-tuned · key=not provided · backbone=Vicuna | Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language ModelsSource quoteL202: 4.25 |
| 2024 | Vicuna Baseline (unprotected) baseline | ROUGE-L | 35.42 | fine-tuned · backbone=Vicuna | Secure Your Model: An Effective Key Prompt Protection Mechanism for Large Language ModelsSource quoteL188: 35.42 |
| 2023 | Proposed method (OURS; RadBloomz fine-tuned with detected-abnormality prompts) proposed | ROUGE-L | 0.373 | split: test · fine-tuned · prompt=detected abnormalities and probabilities · generation-length=128 tokens | Generation of Radiology Findings in Chest X-Ray by Leveraging Collaborative KnowledgeSource quoteL147: OURS │ 0.373 |
| 2022 | Ours (baseline+MSA+MCGN) proposed | ROUGE-L | 0.143 | split: test · fine-tuned · beam-size=3 · reinforcement-learning=no | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299 |
| 2022 | Ours+RL proposed | ROUGE-L | 0.170 | split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr reward | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429 |