MIMIC-CXR

263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

68.772.676.580.32024M-FLAG: 69.5 (2023)DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained): 79.53 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 150 of 158 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026FairLLaVA-All proposedAge-group RadGraph-F1 fairness gap5.60Age-group gap; evaluation aggregates over subgroups of the other demographic attributes…FairLLaVA: Fairness-Aware Parameter-Efficient Fine-Tuning for Large Vision-Language Assistants
Source quote
L680: 0.59 │ 1.01 │ 5.60 │ 12.29
2026LePaX proposedRadGraph F1 (RG_F1)0.346Clinical metric evaluation on MIMIC-CXR.Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report Generation
Source quote
L439: 0.346
2026DiTPO proposedF10.516data_setting=full-dataRethinking the Efficiency and Effectiveness of Reinforcement Learning for Radiology Report Generation
Source quote
L233: Table \ref{table:mimic_results} details the comparative results on the MIMIC-CXR. Our DiTPO model with full-data establishes a new SOTA in clinical accuracy, achieving a F1 score of 0.516. This performance surpasses our basic GRPO framework (0.507) and previous leading RL methods like OISA (0.504), as well as strong SFT baselines such as SS-ACL (0.505), validating the effectiveness of directly optimizing for diagnostic entities.
2026LLaVA-TA proposedRadGraph F131.1fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · evaluation_setting=in-distributionRethinking Radiology Report Generation: From Narrative Flow to Topic-Guided Findings
Source quote
L601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs.
2026ESC-RL proposedF10.608Clinical efficacy (CE) comparison across 14 diseases; split not specified in the cited …Enhancing Reinforcement Learning for Radiology Report Generation with Evidence-aware Rewards and Self-correcting Preference Learning
Source quote
L317: ESC-RL (Ours) │ 0.632 │ 0.625 │ 0.608 │ 0.299 │ 0.311 │ 0.295
2026GRPO ablationF10.507Directly compared with full-data DiTPO in the main results.Rethinking the Efficiency and Effectiveness of Reinforcement Learning for Radiology Report Generation
Source quote
L233: Table \ref{table:mimic_results} details the comparative results on the MIMIC-CXR. Our DiTPO model with full-data establishes a new SOTA in clinical accuracy, achieving a F1 score of 0.516. This performance surpasses our basic GRPO framework (0.507) and previous leading RL methods like OISA (0.504), as well as strong SFT baselines such as SS-ACL (0.505), validating the effectiveness of directly optimizing for diagnostic entities.
2026LLaVA-T ablationRadGraph F11.6fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · anatomical_masks=excluded · evaluation_setting=in-distributionRethinking Radiology Report Generation: From Narrative Flow to Topic-Guided Findings
Source quote
L601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs.
2026CoGaze (full model)14-observation micro-F1 (14Mi-F1)0.525Free-text report generation; metric covers the full set of 14 CheXbert-labeled observat…Seeing Like Radiologists: Context- and Gaze-Guided Vision-Language Pretraining for Chest X-rays
Source quote
L286: Effect of Multi-Level Supervision Paradigm. As shown in Tab.~ \ref{tab:ab-all}, starting from the hybrid-positive contrastive loss {\mathcal{L}-con}, incorporating gaze supervision ({\mathcal{L}-con}+{\mathcal{L}-G}) consistently improves performance across all metrics, with gains of + 0.6% BLEU2, +1.5% (14)Mi-F1, and +1.1% (5)Mi-F1. This suggests that soft gaze guidance provides complementary fine-grained alignment beyond contrastive learning. Further introducing the classification loss {\mathcal{L}-cls}, the full model (CoGaze) achieves the best overall performance, reaching 0.290 BLEU2, 0.596 BERTScore, and 0.525/0.571 on (14)Mi-F1 and (5)Mi-F1, respectively. These results validate the effectiveness of the proposed multi-level supervision paradigm.
2026LLaVA-RadAge-group RadGraph-F1 fairness gap19.97Age-group gap; evaluation aggregates over subgroups of the other demographic attributes…FairLLaVA: Fairness-Aware Parameter-Efficient Fine-Tuning for Large Vision-Language Assistants
Source quote
L632: 3.61 │ 3.39 │ 19.97 │ 16.91
2026BoxMed-RLCheXbert F10.466Downstream report-generation evaluation on MIMIC-CXR; report target is the findings sec…Reason like a radiologist: Chain-of-thought and reinforcement learning for verifiable report generation
Source quote
L807: BoxMed-RL demonstrates stable performance in analyzing clinical concepts, achieving a CheXbert F1 score of 0.466 on MIMIC-CXR and a cosine similarity of 0.610 on IU X-ray. This consistency contrasts with PromptMRG, which shows unstable performance, ranking second in MIMIC-CXR but dropping to fourth in IU X-ray.
2026REVTAFF10.592Clinical efficacy (CE) comparison across 14 diseases; split not specified in the cited …Enhancing Reinforcement Learning for Radiology Report Generation with Evidence-aware Rewards and Self-correcting Preference Learning
Source quote
L312: REVTAF │ \textcolor{blue}{0.628} │ \textcolor{blue}{0.613} │ \textcolor{blue}{0.592} │ \textcolor{blue}{0.286} │ \textcolor{blue}{0.282} │ \textcolor{blue}{0.273}
2026REVTAF baselineF10.589split: testThe Double Dilemma in Multi-Task Radiology Report Generation: A Gradient Dynamics Analysis and Solution
Source quote
L516: REVTAF │ ICCV'25 │ 0.615 │ 0.617 │ 0.589 │ 0.465 │ 0.319 │ 0.236 │ 0.184 │ 0.199 │ 0.336 │ 0.607
2026KARGEN baselineRadGraph F10.203resolution=224×224Graph-Supervised Hierarchical Clinical Alignment for Radiology Report Generation with Large Language Models
Source quote
L401: 0.203 │ 0.421 │ 1.165
2026LLaVA-Rad baselineF1-CheXbert (F1₁₄)0.320condition=full-noise-image · corruption-level=image-levelSHOVIR: A Benchmark for Evaluating Vision Shortcut Learning in Radiology Report Generation
Source quote
L363: Conversely, LLaVA-Rad is the least sensitive to noise, retaining the highest F1\textsubscript{14} under full corruption (0.320 on MIMIC-CXR; 0.175 on PadChest-GR) and yielding the smallest \Delta_{\text{FN}} on both datasets (0.252 and 0.266, respectively), while retaining a moderate GREEN score under Full Noise Image.
2025SS-ACL proposedClinical efficacy macro F10.505split: test · categories=14 thoracic diseases · test-samples=3858 · clinical-labeler=CheXbertSelf-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report Generation
Source quote
L453: {\color[HTML]{C00000} 0.505}
2025MedAlign proposedRadGraph F110.92peft · backbone=LLaVA-Med-1.5 · fine-tuning=without LoRAEnhancing Medical Large Vision-Language Models via Alignment Distillation
Source quote
L441: MedAlign\xspace │ 4.51 │ 18.43 │ 20.80 │ 86.00 │ 25.67 │ 10.92 │ 42.03
2025AM-MRG proposedF10.484Clinical Efficacy (CE) metric on MIMIC-CXR; split and averaging are not specified in th…Activating Associative Disease-Aware Vision Token Memory for LLM-Based X-Ray Report Generation
Source quote
L349: As depicted in Tables \ref{tab:CE_Metrics_Mimic_CXR_results} and \ref{tab:CE_Metrics_CheXpert_Plus_results}, we have evaluated the accuracy of our model, AM-MRG, in delineating clinical abnormalities by reporting the Clinical Efficacy (CE) metrics alongside seven other models across two distinct datasets. On the MIMIC-CXR dataset, AM-MRG yielded impressive results with Precision, Recall, and F1 scores of 0.555, 0.429, and 0.484, respectively. Notably, the Recall and F1 scores surpass those of the competing models, with the F1 score a remarkable 19.5% higher than the second-best model, CoFE~\cite{li2025CoFE}. In the Chexpert Plus dataset, AM-MRG took the lead in all three metrics, achieving Precision, Recall, and F1 scores of 0.396, 0.318, and 0.336, respectively. The F1 score represented a significant 16.6% improvement over the runner-up, Token-Mixer~\cite{Yang2024Token-Mixer}, signifying a substantial edge.
2025DiffRGenNet proposedF10.483split: testDiffRGenNet: Difference-aware Medical Report Generation
Source quote
L286: 0.483
2025MedAlign proposedF195.25%split: test · params=7B · backbone=LLaVA-Med-1.5 7BMedAlign: A Synergistic Framework of Multimodal Preference Optimization and Federated Meta-Cognitive Reasoning
Source quote
L417: MedAlign │ 95.64 │ 96.47 │ 95.25 │ 94.36 │ 22.99 │ 27.89 │ 16.33 │ 2.29
2025CURV proposedRadGraph F119.54params=3BCURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report Generation
Source quote
L277: 19.54
2025MedOrch proposedMacro F1-score25.5%Chest X-ray analysis; macro-level metric.MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible Extensibility
Source quote
L4: Healthcare decision-making represents one of the most challenging domains for Artificial Intelligence (AI), requiring the integration of diverse knowledge sources, complex reasoning, and various external analytical tools. Current AI systems often rely on either task-specific models, which offer limited adaptability, or general language models without grounding with specialized external knowledge and tools. We introduce \texttt{MedOrch}\xspace, a novel framework that orchestrates multiple specialized tools and reasoning agents to provide comprehensive medical decision support. \texttt{MedOrch}\xspace employs a modular, agent-based architecture that facilitates the flexible integration of domain-specific tools without altering the core system. Furthermore, it ensures transparent and traceable reasoning processes, enabling clinicians to meticulously verify each intermediate step underlying the system’s recommendations. We evaluate \texttt{MedOrch}\xspace across three distinct medical applications: Alzheimer's disease diagnosis, chest X-ray interpretation, and medical visual question answering, using authentic clinical datasets. The results demonstrate \texttt{MedOrch}\xspace's competitive performance across these diverse medical tasks. Notably, in Alzheimer's disease diagnosis, \texttt{MedOrch}\xspace achieves an accuracy of 93.26%, surpassing the state-of-the-art baseline by over four percentage points. For predicting Alzheimer's disease progression, it attains a 50.35% accuracy, marking a significant improvement. In chest X-ray analysis, \texttt{MedOrch}\xspace exhibits superior performance with a Macro AUC of 61.2% and a Macro F1-score of 25.5%. Moreover, in complex multimodal visual question answering (Image+Table), \texttt{MedOrch}\xspace achieves an accuracy of 54.47%. These findings underscore \texttt{MedOrch}\xspace's potential to advance healthcare AI by enabling reasoning-driven tool utilization for multimodal medical data processing and supporting intricate cognitive tasks in clinical decision-making.
2025MCA-RG (7B; listed as Ours) proposedExample-based F10.408split: test · params=7B · scores=CE · averaging=example-basedMCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report Generation
Source quote
L172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt]
2025MCA-RG (7B; listed as Ours) proposedMacro-based F10.335split: test · params=7B · scores=CE · averaging=macro-basedMCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report Generation
Source quote
L172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt]
2025ChexGen-balanced DenseNet121 model proposedWeighted F1-score for worst-performing gender group0.387split: test · model=DenseNet121 · subgroup=worst-performing gender group · training-data=ChexGen-balancedA Generative Foundation Model for Chest Radiography
Source quote
L160: In addition to detecting model bias, we explored whether synthetic data could be used to further mitigate the observed bias. Using ChexGen, we generated additional training samples for underrepresented demographic subgroups until their representation matched that of the majority groups. Consequently, the augmented training data led to substantial improvements in model fairness across all demographic dimensions. For instance, the F1-Scores increased significantly for the worst group (gender: 0.338 to 0.387, race: 0.321 to 0.394, age: 0.363 to 0.419), while performance gaps between best and worst groups narrowed considerably with a relative reduction of up to 60% (gender: 2.5% to 1.6%, race: 2.9% to 1.2%, age: 2.3% to 1.2%) (\textbf{\cref{fig:figure6}d}). These results highlight the potential of CheXGen for generating synthetic data to enhance model fairness by detecting and mitigating bias.
2025MAIRA-2 + CCD proposedRadGraph-F119.01Radiology report generation; CCD applied to MAIRA-2.CCD: Mitigating Hallucinations in Radiology MLLMs via Clinical Contrastive Decoding
Source quote
L478: \(+\) CCD │ 20.70 │ 2.10 │ 51.62 │ 19.01 │ 17.58 │ 53.32 │ 17.50 │ 27.05 │ 16.02
2025OTDRG proposedClinical efficacy F10.436disease-labels=14 · clinical-labeler=CheXbertBridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMs
Source quote
L277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295
2025CoCa-CXR, description-only generation proposedRadGraph F124.2%Generates descriptions only; CoCa-CXR and the compared models rely solely on images as …CoCa-CXR: Contrastive Captioners Learn Strong Temporal Structures for Chest X-Ray Vision-Language Understanding
Source quote
L127: Tab.~\ref{tab:mimic-cxr} presents report generation results on the MIMIC-CXR dataset \cite{johnson2019mimic}. CoCa-CXR predicts both FINDINGS and IMPRESSION sections, a more challenging task than FINDINGS alone \cite{bannur2023learning}. When generating only descriptions, it achieves a RadGraph F1 score of 24.2%, on par with large-scale models like Med-Gemini \cite{yang2024advancing}. Notably, PaliGemma-2 \cite{steiner2024paligemma} incorporates both images and the indication section as inputs, whereas CoCa-CXR and other models in Tab.~\ref{tab:mimic-cxr} rely solely on images; hence, we exclude its result for fair comparison.
2025CoCa-CXR, generating comparison descriptions proposedRadGraph F123.7%Generates comparison descriptions in addition to descriptions.CoCa-CXR: Contrastive Captioners Learn Strong Temporal Structures for Chest X-Ray Vision-Language Understanding
Source quote
L128: When also generating comparison descriptions, CoCa-CXR attains a RadGraph F1 score of 23.7%. Although this is slightly lower than description-only generation, our hypothesis is that, describing progression adds another dimension to report generation tasks, and with the current accuracy-level (65%) on temporal classification, one can obtain a similar level of benefit on Radgraph F1 by simply omitting comparisons in the generated reports. But still, as shown in Fig. \ref{fig:pos_vs_neg_order}, this is step forward in incorporating this progression dimension and towards real world application.
2025RADAR proposedRG-F10.346view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge Injection
Source quote
L224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports.
2025RADAR proposed14-observation macro-average F10.460backbone=BLIP-3 · beam-width=5 · resolution=384×384RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge Injection
Source quote
L288: (14)Macro Average │ 0.481 │ 0.474 │ 0.460
2025RADAR proposed5-observation macro-average F10.567backbone=BLIP-3 · beam-width=5 · resolution=384×384RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge Injection
Source quote
L276: ^5Macro Average │ 0.551 │ 0.602 │ 0.567
2025Weighted Avg (W-Avg; PRM scores) proposedF1-CheXbert0.3575split: test · subset=full-unbalanced · strategy=weighted-average · generator=MAIRA-2 · candidates=128 · temperature=1.0Process Reward Models for Sentence-Level Verification of LVLM Radiology Reports
Source quote
L536: Our results (Figures~\ref{fig:bon_weighted_all} and \ref{fig:bon_nonweighted_all}) show that weighted strategies generally outperform non-weighted ones. For instance, Weighted Avg (W-Avg) using PRM scores improves F1-CheXbert by +5.0 points (0.3575 vs 0.3077 for non-weighted AvgProb) at N=128. Similarly, W-Avg boosts BERTScore by +0.001 points (0.8594 vs 0.8584) under the same conditions. The choice of N also impacts performance, with larger N generally leads to better results.
2025MLRG proposedmicro avg F10.505Clinical accuracy across 14 CheXpert-annotated observations; micro average. The cited t…Enhanced Contrastive Learning with Multi-view Longitudinal Data for Chest X-ray Report Generation
Source quote
L259: micro avg │ 0.523 │ 0.410 │ 0.460 │ 0.549 │ 0.468 │ 0.505 │ 0.522 │ 0.447 │ 0.481 │ 0.532 │ 0.474 │ 0.501
2025KIA proposed non-standard sliceF1-Score0.461split: test · clinical-labels=14 CheXpert abnormality categoriesKIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report Generation
Source quote
L477: 0.461
2025EMRRG proposedF10.395fine-tunedEMRRG: Efficient Fine-Tuning Pre-trained X-ray Mamba Networks for Radiology Report Generation
Source quote
L208: EMRRG │ Ours │ 0.421 │ 0.372 │ 0.395
2025RadFM with V-RAG and no listed fine-tuning tasks ablationF10.721fine-tunedReducing Hallucinations of Medical Multimodal Large Language Models with Visual Retrieval-Augmented Generation
Source quote
L336: 0.721 │ 0.920
2025+ Hybrid-RAG ablationF176.68%split: test · params=7B · variant=Hybrid-RAG · backbone=LLaVA-Med-1.5 7BMedAlign: A Synergistic Framework of Multimodal Preference Optimization and Federated Meta-Cognitive Reasoning
Source quote
L415: + Hybrid-RAG │ 78.12 │ 76.71 │ 76.68 │ 76.66 │ 15.91 │ 18.90 │ 12.82 │ 3.17
2025w/o Fine-grained Grounding (S1→S2) ablationF10.513PAG ablation; fine-grained grounding stage omitted. MIMIC-CXR samples lacking RadGraph …S2D-ALIGN: Shallow-to-Deep Auxiliary Learning for Anatomically-Grounded Radiology Report Generation
Source quote
L328: w/o Fine-grained Grounding (S1\rightarrowS2) │ 0.386 │ 0.112 │ 0.303 │ 0.513
2025Non-weighted AvgProb (PRM-based BoN) ablationF1-CheXbert0.3077split: test · subset=full-unbalanced · strategy=non-weighted-AvgProb · generator=MAIRA-2 · candidates=128 · temperature=1.0Process Reward Models for Sentence-Level Verification of LVLM Radiology Reports
Source quote
L536: Our results (Figures~\ref{fig:bon_weighted_all} and \ref{fig:bon_nonweighted_all}) show that weighted strategies generally outperform non-weighted ones. For instance, Weighted Avg (W-Avg) using PRM scores improves F1-CheXbert by +5.0 points (0.3575 vs 0.3077 for non-weighted AvgProb) at N=128. Similarly, W-Avg boosts BERTScore by +0.001 points (0.8594 vs 0.8584) under the same conditions. The choice of N also impacts performance, with larger N generally leads to better results.
2025Gemini 2.5 proRadGraph F17.71Radiology report generation; clinical accuracy metric, directly compared with CURV in t…CURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report Generation
Source quote
L259: 7.71
2025RA-RRG (E12)RadGraph F126.7split: testLeveraging LLMs for Multimodal Retrieval-Augmented Radiology Report Generation via Key Phrase Extraction
Source quote
L377: RA-RRG │ F │ 3,858 │ 58.5 │ 62.1 │ 41.7 │ 52.9 │ 50.7 │ 26.7 │ 3.18 │ 24.9 │ 37.9 │ 8.0
2025Med-PaLM M 84BRadGraph F126.7split: test · params=84BLeveraging LLMs for Multimodal Retrieval-Augmented Radiology Report Generation via Key Phrase Extraction
Source quote
L361: Med-PaLM M 84B \cite{medpalm-m} │ F │ 4,834 │ 53.6 │ 57.9 │ 39.8 │ 51.6 │ 26.7 │ 27.3 │ 32.3 │ 11.3
2025PromptMRG baselineF1 (CE)0.476split: test · domain=seenARDGen: Augmentation Regularization for Domain-Generalized Medical Report Generation
Source quote
L284: 0.476
2025DCG baselineClinical efficacy macro F10.404split: test · categories=14 thoracic diseases · clinical-labeler=CheXbertSelf-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report Generation
Source quote
L437: {\color[HTML]{4472C4} 0.404}
2025A^3Tune baselineRadGraph F110.52peft · backbone=LLaVA-Med-1.5 · fine-tuning=without LoRAEnhancing Medical Large Vision-Language Models via Alignment Distillation
Source quote
L440: A^3Tune │ 4.22 │ 18.02 │ 20.69 │ 85.75 │ 25.37 │ 10.52 │ 42.15
2025PromptMRG baselineF10.476split: testDiffRGenNet: Difference-aware Medical Report Generation
Source quote
L277: 0.476
2025I3 + C2FD baselineF10.473Clinical-efficacy evaluation on generated reports labeled using CheXpert; official MIMI…DART: Disease-aware Image-Text Alignment and Self-correcting Re-alignment for Trustworthy Radiology Report Generation
Source quote
L144: I3 + C2FD~\cite{liu2024bootstrapping} │ 0.473 │ 0.465 │ 0.482
2025WarmStart baselineMacro-based F10.306split: test · scores=CE · averaging=macro-basedMCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report Generation
Source quote
L168: WarmStart\cite{warm_start} │ 2023 │ \ding{55} │ 0.418 │ 0.367 │ \multicolumn{1}{c|}{0.367} │ 0.417 │ 0.295 │ 0.306
2025Original biased DenseNet121 model baselineWeighted F1-score for worst-performing gender group0.338split: test · model=DenseNet121 · subgroup=worst-performing gender groupA Generative Foundation Model for Chest Radiography
Source quote
L160: In addition to detecting model bias, we explored whether synthetic data could be used to further mitigate the observed bias. Using ChexGen, we generated additional training samples for underrepresented demographic subgroups until their representation matched that of the majority groups. Consequently, the augmented training data led to substantial improvements in model fairness across all demographic dimensions. For instance, the F1-Scores increased significantly for the worst group (gender: 0.338 to 0.387, race: 0.321 to 0.394, age: 0.363 to 0.419), while performance gaps between best and worst groups narrowed considerably with a relative reduction of up to 60% (gender: 2.5% to 1.6%, race: 2.9% to 1.2%, age: 2.3% to 1.2%) (\textbf{\cref{fig:figure6}d}). These results highlight the potential of CheXGen for generating synthetic data to enhance model fairness by detecting and mitigating bias.
2025MAIRA-2 baseline baselineRadGraph-F116.23Radiology report generation; MAIRA-2 is the baseline identified in the table caption.CCD: Mitigating Hallucinations in Radiology MLLMs via Clinical Contrastive Decoding
Source quote
L466: Baseline │ 19.57 │ 1.61 │ 49.56 │ 16.23 │ 12.11 │ 50.82 │ 16.96 │ 16.14 │ 10.57
2025MAIRA-2 baseline baselineCheXbert-F1 (5-class)16.14Radiology report generation; five-class CheXbert-F1; MAIRA-2 is the baseline identified…CCD: Mitigating Hallucinations in Radiology MLLMs via Clinical Contrastive Decoding
Source quote
L466: Baseline │ 19.57 │ 1.61 │ 49.56 │ 16.23 │ 12.11 │ 50.82 │ 16.96 │ 16.14 │ 10.57
2025PromptMRG baselineClinical efficacy F10.476disease-labels=14 · clinical-labeler=CheXbertBridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMs
Source quote
L273: PromptMRG │ 2024 │ 0.501 │ 0.509 │ 0.476 │ 0.398 │ 0.112 │ 0.157 │ 0.268 \
2025No-rejection baseline (0% rejection) baselineF1-CheXbert0.32934split: test · subset=full-unbalanced · generator=MAIRA-2 · rejection=noneProcess Reward Models for Sentence-Level Verification of LVLM Radiology Reports
Source quote
L513: F1-CheXbert │ 0% │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934
2025SEI baselinemicro avg F10.460Clinical accuracy across 14 CheXpert-annotated observations; micro average. The cited t…Enhanced Contrastive Learning with Multi-view Longitudinal Data for Chest X-ray Report Generation
Source quote
L259: micro avg │ 0.523 │ 0.410 │ 0.460 │ 0.549 │ 0.468 │ 0.505 │ 0.522 │ 0.447 │ 0.481 │ 0.532 │ 0.474 │ 0.501
2025DCL baseline non-standard sliceF1-Score0.373split: test · clinical-labels=14 CheXpert abnormality categoriesKIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report Generation
Source quote
L465: 0.373
2025Qwen-VL + RAG baseline non-standard sliceF185.98%RAG reference condition; no poisoning is listed for this row.How to make Medical AI Systems safer? Simulating Vulnerabilities, and Threats in Multimodal Medical RAG System
Source quote
L217: + RAG │ 82.94 │ 69.77 │ 75.34 │ 72.46 │ 86.01 │ 86.86 │ 85.12 │ 85.98
2024FSE-1 proposedCX14 (CheXbert micro-F1, 14 categories)0.470split: test · reference-report-truncation=M_gt=80Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report Generation
Source quote
L229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency.
2024EVOKE (multi-view; Stage 1 fact-serialization alignment with MPC, G, and L; Stage 2 indication and bridge enabled) proposedF1 RadGraph (RG)0.276resolution=224×224MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report Generation
Source quote
L180: EVOKE │ M │ F │ \ding{51} │ \ding{51} │ \ding{51} │ \ding{51} (\ding{51}) │ 0.262 │ 0.147 │ 0.167 │ 0.311 │ 0.276 │ 0.557 │ 0.499
2024CLIP(SapBERT)+AHIVE proposedCE(11/5) micro-average F10.678split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impressionAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L499: 0.678
2024CLIP(SapBERT)+AHIVE proposedCE(11) micro-average F10.604split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impressionAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L498: 0.604
2024CLIP(SapBERT)+AHIVE proposedCE(13+NL) micro-average F10.685split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impressionAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L500: 0.685
2024Libra proposedMacro-F1-553.8%CheXpert F1 for the five most common findings; concurrent-work comparison, with differi…Libra: Leveraging Temporal Images for Biomedical Radiology Analysis
Source quote
L583: Macro-F1-5 │ -- │ -- │ 51.5 │ 49.5 │ 53.8 (4.5%)
2024SGRRG proposed non-standard sliceMacro-average F1 (clinical efficacy)0.332split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024TRRG full configuration (BASE + DCI + CMCI + DAL) proposedF10.393Full ablation configuration: DCI, CMCI, and DAL added to BASE; split not specified in t…TRRG: Towards Truthful Radiology Report Generation With Cross-modal Disease Clue Enhanced Large Language Model
Source quote
L248: 4 │ \multicolumn{1}{l|}{+DCI+CMCI+DAL} │ 0.151 │ 0.377 │ 0.209 │ 0.405 │ 0.157 │ 0.336 │ 0.167 │ 0.219 │ 0.393
2024ChEX (VinDr-CXR and MIMIC-CXR training) proposedEx-F1-1458.76split: test · 0-shotChEX: Interactive Localization and Region Description in Chest X-Rays
Source quote
L636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}}
2024ChEX (VinDr-CXR and MIMIC-CXR training) proposedMic-F1-5+61.03split: test · 0-shotChEX: Interactive Localization and Region Description in Chest X-Rays
Source quote
L636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}}
2024ChEX (VinDr-CXR and MIMIC-CXR training) proposedMac-F1-5+55.85split: test · 0-shotChEX: Interactive Localization and Region Description in Chest X-Rays
Source quote
L636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}}
2024Ours (pathology-aware regional prompts; PARP) proposedF1-score0.470Automated clinical-efficacy metric; compared with state-of-the-art report-generation me…Anatomy-Guided Radiology Report Generation with Pathology-Aware Regional Prompts
Source quote
L397: 0.470 \Xhline{1pt}
2024Teaser proposedF1-score0.526Clinical-efficacy metric over 14 disease categories; split and averaging details are no…Topicwise Separable Sentence Retrieval for Medical Report Generation
Source quote
L317: Specifically, our Precision metric increases from 0.501 to 0.534, Recall increases from 0.509 to 0.518, and F1-score increases from 0.476 to 0.526.
2024IVGN proposedF1-score (CE)0.398split: testIntensive Vision-guided Network for Radiology Report Generation
Source quote
L293: IVGN │ 0.377 │ 0.236 │ 0.158 │ 0.112 │ 0.144 │ 0.280 │ 0.415 │ 0.442 │ 0.398
2024LM-RRG proposedF10.484Main comparison table; clinical efficacy metric. Split not stated.Large Model driven Radiology Report Generation with Clinical Quality Reinforcement Learning
Source quote
L193: LM-RRG(Ours) │ 0.122 │ 0.165 │ 0.296 │ 0.500 │ 0.500 │ 0.484 │ 0.865
2024MedImageInsight proposedCheXbert Micro-avg F1-1453.6split: test · params=0.4BMedImageInsight: An Open-Source Embedding Model for General Domain Medical Imaging
Source quote
L203: MedImageInsight\xspace \tnote{a} │ 53.6 │ 57.2 │ 37.0 │ 48.3 │ 53.3 │ 58.6 │ 40.7 │ 51.7 │ 25.5 │ 28.8 │ 37.0 │ 15.2 │ 31.6
2024MedCycle {CheXpert} proposedF10.183Clinical efficacy on MIMIC-CXR; images from CheXpert and reports from MIMIC-CXR for tra…MedCycle: Unpaired Medical Report Generation via Cycle-Consistency
Source quote
L349: MedCycle {CheXpert} │ 0.230 │ 0.171 │ 0.183
2024MedCycle {Xlate} proposedF10.198Clinical efficacy on MIMIC-CXR; images from PadChest and reports from MIMIC-CXR for tra…MedCycle: Unpaired Medical Report Generation via Cycle-Consistency
Source quote
L351: MedCycle {Xlate} │ 0.218 │ 0.209 │ 0.198
2024CoFE (+ \mathcal{L}-CF, full) proposedF1-score0.405Clinical efficacy evaluation on MIMIC-CXR.Contrastive Learning with Counterfactual Explanations for Radiology Report Generation
Source quote
L173: + \mathcal{L}-CF (full) │ 0.489 │ 0.370 │ 0.405
2024DCRRG proposedclinical efficacy F10.376Clinical-efficacy evaluation on MIMIC-CXR; disease labels are extracted from reports.Divide and Conquer Radiology Report Generation via Observation Level Fine-grained Pretraining and Prompt Tuning
Source quote
L287: 0.376
2024RayDINO proposedRadGraph F123.9split: testAdvancing human-centric AI for robust X-ray analysis through holistic self-supervised learning
Source quote
L278: RayDINO │ 13.8\ci{13.4}{14.2} │ 30.3\ci{29.7}{30.8} │ 23.9\ci{23.3}{24.6} │ 44.8\ci{44.0}{45.6} │ 3.07\ci{3.04}{3.11} │ 36.1\ci{34.4}{37.6} │ 54.8\ci{53.5}{56.0}
2024GenX+AC (t=0)_1 proposedF1 score54.3split: test · backbone=ResNet-18 · auditing-component=AC · confidence-threshold=0Quality Control for Radiology Report Generation Models via Auxiliary Auditing Components
Source quote
L192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3
2024GenX+AC (t=0.8)_1 proposedF1 score58.4split: test · backbone=ResNet-18 · auditing-component=AC · confidence-threshold=0.8Quality Control for Radiology Report Generation Models via Auxiliary Auditing Components
Source quote
L192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3
2024Llama 3.1 Instruct-8B (9,000-sample joint training) proposedmicro-F10.67fine-tuned · params=8B · label-source=NegBio-derived · training-samples=9000Enhancing disease detection in radiology reports through fine-tuning lightweight LLM on weak labels
Source quote
L210: 9,000 │ 6,000 │ 3,000 │ 0.62 │ 0.72 │ 0.67 │ 0.44 │ 0.83 │ 0.58
2024Ablation (a), direct Stage-2-only multi-view configuration (indication and bridge enabled) ablationF1 RadGraph (RG)0.252resolution=224×224MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report Generation
Source quote
L170: (a) │ M │ \ding{55} │ \ding{55} │ \ding{55} │ \ding{51} (\ding{51}) │ 0.247 │ 0.134 │ 0.158 │ 0.296 │ 0.252 │ 0.545 │ 0.480
2024Ablation (h), multi-view with Stage 1 alignment losses; indication and bridge disabled ablationF1 RadGraph (RG)0.230resolution=224×224MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report Generation
Source quote
L177: (h) │ M │ F │ \ding{51} │ \ding{51} │ \ding{51} │ \ding{55} (\ding{55}) │ 0.226 │ 0.108 │ 0.148 │ 0.279 │ 0.230 │ 0.539 │ 0.477
2024Uncorrected retrieval ablation non-standard sliceCE F10.183Clinical-efficacy metric; evaluation against ground truth using the retrieval model bef…MedAutoCorrect: Image-Conditioned Autocorrection in Medical Reporting
Source quote
L213: \multirow{11}{*}{\rotatebox[origin=c]{90}{MIMIC-CXR}} │ Uncorrected retrieval (Ours) │ 0.216 │ 0.108 │ 0.056 │ 0.029 │ 0.051 │ 0.187 │ 0.192 │ 0.173 │ 0.183
2024Prompt-guided structured report generation model, ablation (b) ablationClinical effectiveness (CE) F10.404prompt=custom-prompt-C · variant=ablation-bPrompt-Guided Generation of Structured Chest X-Ray Report Using a Pre-trained LLM
Source quote
L152: (b) │ \(\checkmark\) │ \(\checkmark\) │ 0.233 │ 0.404 │ 0.432 │ 0.432
2024Prompt-guided structured report generation model, ablation (f) ablationClinical effectiveness (CE) F10.441prompt=custom-prompt-C · variant=ablation-fPrompt-Guided Generation of Structured Chest X-Ray Report Using a Pre-trained LLM
Source quote
L156: (f) │ \(\checkmark\) │ \(\checkmark\) │ \(\checkmark\) │ \(\checkmark\) │ \(\checkmark\) │ 0.231 │ 0.441 │ 0.469 │ 0.470
2024MPOF10.353Clinical-metric comparison; split and preference configuration not specified in the cit…Radiology Report Generation via Multi-objective Preference Optimization
Source quote
L206: MPO │ ours │ 0.436 │ 0.376 │ 0.353
2024KGAE {CheXpert}F10.156Clinical efficacy on MIMIC-CXR; images from CheXpert for training. The comparison setup…MedCycle: Unpaired Medical Report Generation via Cycle-Consistency
Source quote
L348: KGAE {CheXpert} │ 0.214 │ 0.158 │ 0.156
2024CXR-RePaiR baselineCE(11/5) micro-average F10.654runs=3-run averageAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L489: 0.654
2024CXR-RePaiR baselineCE(11) micro-average F10.564runs=3-run averageAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L488: 0.564
2024CXR-RePaiR baselineCE(13+NL) micro-average F10.660runs=3-run averageAHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval
Source quote
L490: 0.660
2024MAIRA-1 baselineMic-F1-5+58.8split: testChEX: Interactive Localization and Region Description in Chest X-Rays
Source quote
L645: MAIRA-1\cite{maira} \training{\textcolor{MidnightBlue}{M}} │ 55.7 │ -- │ 38.6 │ 58.8 │ 51.7
2024MAIRA-1 baselineMac-F1-5+51.7split: testChEX: Interactive Localization and Region Description in Chest X-Rays
Source quote
L645: MAIRA-1\cite{maira} \training{\textcolor{MidnightBlue}{M}} │ 55.7 │ -- │ 38.6 │ 58.8 │ 51.7
2024PromptMRG baselineF1-score0.476Clinical-efficacy metric over 14 disease categories; split and averaging details are no…Topicwise Separable Sentence Retrieval for Medical Report Generation
Source quote
L317: Specifically, our Precision metric increases from 0.501 to 0.534, Recall increases from 0.509 to 0.518, and F1-score increases from 0.476 to 0.526.
2024\textsc{\mathcal{M}^2Tr.Progressive} baselineF1-score (CE)0.308split: testIntensive Vision-guided Network for Radiology Report Generation
Source quote
L292: \textsc{\mathcal{M}^2Tr.Progressive} │ 0.378 │ 0.232 │ 0.154 │ 0.107 │ 0.145 │ 0.272 │ 0.240 │ 0.428 │ 0.308
2024GPT-4o finetune baselineCheXbert Micro-avg F1-1448.9split: test · fine-tunedMedImageInsight: An Open-Source Embedding Model for General Domain Medical Imaging
Source quote
L187: GPT-4o finetune\tnote{d} │ 48.9 │ 52.7 │ 33.0 │ 43.8 │ 49.3 │ 54.7 │ 36.7 │ 47.8 │ 26.4 │ 29.3 │ 39.6 │ 17.8 │ 32.1
2024DCL baselineclinical efficacy F10.373Clinical-efficacy baseline on MIMIC-CXR; disease labels are extracted from reports.Divide and Conquer Radiology Report Generation via Observation Level Fine-grained Pretraining and Prompt Tuning
Source quote
L247: 0.373
2024MAIRA-1 baselineRadGraph F122.8split: testAdvancing human-centric AI for robust X-ray analysis through holistic self-supervised learning
Source quote
L272: \text{MAIRA-1 } │ 14.0\ci{13.6}{14.5} │ 28.5\ci{28.0}{28.9} │ 22.8\ci{22.1}{23.3} │ 42.8\ci{42.0}{43.6} │ 3.16\ci{3.13}{3.19} │ 36.7\ci{35.0}{38.2} │ 54.3\ci{53.3}{55.4}
2024GenX (unfiltered) baselineF1 score46.8split: testQuality Control for Radiology Report Generation Models via Auxiliary Auditing Components
Source quote
L192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3
2024NegBio baselinemicro-F10.63fine-tuned · method-type=rule-basedEnhancing disease detection in radiology reports through fine-tuning lightweight LLM on weak labels
Source quote
L212: NegBio │ 0.82 │ 0.51 │ 0.63
2023ChatCAD (Ours, ChatGPT) proposedF10.605prompt=Prompt#3ChatCAD: Interactive Computer-Aided Diagnosis on Medical Image using Large Language Models
Source quote
L112: \multicolumn{2}{c}{Average} │ 0.312 │ 0.476 │ 0.368 │ 0.616 │ 0.382 │ 0.441 │ 0.504 │ 0.781 │ 0.591 │ {0.549} │ 0.726 │ 0.605
2023ChatCAD (Ours, GPT-3) proposedF10.591prompt=Prompt#3ChatCAD: Interactive Computer-Aided Diagnosis on Medical Image using Large Language Models
Source quote
L112: \multicolumn{2}{c}{Average} │ 0.312 │ 0.476 │ 0.368 │ 0.616 │ 0.382 │ 0.441 │ 0.504 │ 0.781 │ 0.591 │ {0.549} │ 0.726 │ 0.605
2023XproNet + ITHN proposed non-standard sliceF10.317Clinical efficacy metric on MIMIC-CXR; generated reports are labeled with a CheXpert-tr…Automatic Radiology Report Generation by Learning with Increasingly Hard Negatives
Source quote
L215: XproNet + \textbf{\text{ITHN}} │ 0.362 │ 0.283 │ 0.317 │ 0.82
2023CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposedF1-cheXbert76.29split: test · evaluation=RadSum23 public testKU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report Summarization
Source quote
L148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96
2023CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposedF1-Radgraph50.96split: test · evaluation=RadSum23 public testKU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report Summarization
Source quote
L148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96
2023PromptMRG proposedF1 score (clinical efficacy)0.476split: test · evaluation=CheXbert 14-disease-label clinical efficacyPromptMRG: Diagnosis-Driven Prompts for Medical Report Generation
Source quote
L190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details.
2023Pragmatic LLaMA proposedPos F10.307split: test · fine-tuned · epochs=3 · section=impression · training-examples=18264Pragmatic Radiology Report Generation
Source quote
L383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158
2023Pragmatic Retrieval proposedNeg F1-50.156split: test · section=impression · metric-subset=five most frequent negative labelsPragmatic Radiology Report Generation
Source quote
L382: Pragmatic Retrieval │ 0.293 │ 0.403 │ 0.103 │ 0.072 │ -0.103 │ 0.078 │ -0.084 │ \bf 0.077 │ \bf 0.156 │ 0.445
2023Pragmatic LLaMA proposedNeg F1-50.127split: test · fine-tuned · epochs=3 · section=impression · metric-subset=five most frequent negative labels · training-examples=18264Pragmatic Radiology Report Generation
Source quote
L383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158
2023KiUT proposedF10.321split: test · input-images=single-image · label-source=CheXpertKiUT: Knowledge-injected U-Transformer for Radiology Report Generation
Source quote
L229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321
2023Proposed longitudinal model with sentence-anatomy dropout proposedF1 (CE)0.553split: test · report_scope=full · prior_cxr_input=enabled · sentence_anatomy_dropout=enabledControllable Chest X-Ray Report Generation from Longitudinal Representations
Source quote
L363: 0.553
2023Proposed longitudinal model with sentence-anatomy dropout proposed non-standard sliceF1 (CE)0.672split: test · report_scope=partial · prior_cxr_input=enabled · sentence_anatomy_dropout=enabledControllable Chest X-Ray Report Generation from Longitudinal Representations
Source quote
L486: 0.672
2023DCL (row “Ours”) proposedF1-score0.373split: test · labels=CheXpert 14 medical terminologies · evaluation=clinical efficacyDynamic Graph Enhanced Contrastive Learning for Chest X-ray Report Generation
Source quote
L205: Ours │ 0.471 │ 0.352 │ 0.373
2023ORGan proposedF1 (F_1; clinical efficacy)0.385split: test · labeler=CheXpert · evaluation=clinical-efficacyORGAN: Observation-Guided Radiology Report Generation via Tree Reasoning
Source quote
L241: \multirow{4}{*}{\textsc{\makecell{MIMIC\\-CXR}}} │ ORGan │ {0.407} │ {0.256} │ {0.172} │ {0.123} │ {0.162} │ {0.293} │ {0.416} │ {0.418} │ {0.385}
2023ChatCAD+ (P3) proposedF10.564split: test · llm=ChatGPT · subset=1,000 samples; five findings · retrieval-k=3ChatCAD+: Toward a Universal and Reliable Interactive CAD Using LLMs
Source quote
L311: ChatCAD+ (P3) │ 256M+175B │ 4.409 │ 17.344 │ 24.337 │ 0.531 │ 0.615 │ 0.564
2023R2GenGPT (Deep) proposed non-standard sliceF10.389Clinical efficacy evaluation on MIMIC-CXR using CheXpert annotations of generated repor…R2GenGPT: Radiology Report Generation with frozen LLMs
Source quote
L184: Deep │ \checkmark │ \checkmark │ 90.9M │ 2.75h/epo │ 0.392 │ 0.387 │ 0.389
2023PromptMRG ablation baseline (no added modules) ablationF1 score (clinical efficacy)0.370split: test · evaluation=CheXbert 14-disease-label clinical efficacy · configuration=baseline onlyPromptMRG: Diagnosis-Driven Prompts for Medical Report Generation
Source quote
L195: To verify the effectiveness of each module, we do ablation study on MIMIC test set, which is shown in Table 2. Firstly, we see that the baseline only achieves fair CE performance (e.g., a F1 score of 0.370). By adding DDP, the F1 score increases significantly to 0.444, indicating the effectiveness of DDP in producing diagnostically correct reports. Adding auxiliary disease labeling (ADL) also benefits CE results, improves F1 score to 0.451. When CFE and SDL are further applied, the F1 score improves to 0.464 and 0.468, respectively. Finally, utilizing all the modules yields the best F1 score of 0.476. We notice that ADL and CFE improve both precision and recall while SDL is more helpful for recall. We believe this is related to the mechanism of SDL, which encourages the learning of less-learned diseases on recalling positive cases. On the other hand, the usage of DDP degrades the NLG performance by about 0.8% on average. Through an examination of the N-gram statistics of the generated reports (see Appendix), we have noted that the baseline is more likely to repeat the frequent phrases from the training set in comparison to the model that utilizes DDP. We suspect it is because DDP provides extra diagnostic information during the generation process, making the generated texts more diverse and less susceptible to high-frequency phrases. Consequently, the NLG performance would exhibit a decline with DDP, as a result of fewer matched phrases. When CFE and SDL are further added, the NLG performance increases, but still lags behind the baseline (except for BLEU-1). Overall, the proposed modules substantially improve the CE performance at the expense of slightly degraded NLG performance.
2023PromptMRG ablation baseline with DDP ablationF1 score (clinical efficacy)0.444split: test · evaluation=CheXbert 14-disease-label clinical efficacy · configuration=baseline plus DDPPromptMRG: Diagnosis-Driven Prompts for Medical Report Generation
Source quote
L195: To verify the effectiveness of each module, we do ablation study on MIMIC test set, which is shown in Table 2. Firstly, we see that the baseline only achieves fair CE performance (e.g., a F1 score of 0.370). By adding DDP, the F1 score increases significantly to 0.444, indicating the effectiveness of DDP in producing diagnostically correct reports. Adding auxiliary disease labeling (ADL) also benefits CE results, improves F1 score to 0.451. When CFE and SDL are further applied, the F1 score improves to 0.464 and 0.468, respectively. Finally, utilizing all the modules yields the best F1 score of 0.476. We notice that ADL and CFE improve both precision and recall while SDL is more helpful for recall. We believe this is related to the mechanism of SDL, which encourages the learning of less-learned diseases on recalling positive cases. On the other hand, the usage of DDP degrades the NLG performance by about 0.8% on average. Through an examination of the N-gram statistics of the generated reports (see Appendix), we have noted that the baseline is more likely to repeat the frequent phrases from the training set in comparison to the model that utilizes DDP. We suspect it is because DDP provides extra diagnostic information during the generation process, making the generated texts more diverse and less susceptible to high-frequency phrases. Consequently, the NLG performance would exhibit a decline with DDP, as a result of fewer matched phrases. When CFE and SDL are further added, the NLG performance increases, but still lags behind the baseline (except for BLEU-1). Overall, the proposed modules substantially improve the CE performance at the expense of slightly degraded NLG performance.
2023Vanilla Transformer (baseline) ablationF1-score (F1)0.320Clinical-efficacy metric; ablation study without CSS or CRR augmentation.Rethinking Radiology Report Generation via Causal Inspired Counterfactual Augmentation
Source quote
L233: \multirow{8}{*}{MIMIC-CXR} │ Vanilla │ 0.782 │ 0.256 │ 0.427 │ 0.320
2023Vanilla Transformer + CSS & CRR ablationF1-score (F1)0.413Clinical-efficacy metric; ablation study with the CSS and CRR ensemble.Rethinking Radiology Report Generation via Causal Inspired Counterfactual Augmentation
Source quote
L236: /w CSS \ │ CRR │ 0.801 │ 0.348 │ 0.507 │ 0.413
2023Flamingo-CXR (F + I)CheXpert F1 (all)0.519split: testConsensus, dissensus and synergy between clinicians and specialist foundation models in radiology report generation
Source quote
L218: Flamingo-CXR (Ours) │ F + I │ \gradientcdr{0.138} │ \gradientblu{0.101} │ \textbf{\gradientrou{0.297}} │ \textbf{\gradientall{0.519}} │ \textbf{\gradienttop{0.580}} │ \gradientrad{0.205}
2023Med-PaLM-M, 12B (F only)CheXpert F1 (all)0.514params=12BConsensus, dissensus and synergy between clinicians and specialist foundation models in radiology report generation
Source quote
L212: Med-PaLM-M, 12B \citep{tu2023generalist} │ F │ \gradientcdr{0.234} │ \gradientblu{0.104} │ \gradientrou{0.262} │ \gradientall{0.514} │ \gradienttop{0.565} │ \textbf{\gradientrad{0.252}}
2023Flamingo-CXR (F + I)Radgraph F10.205split: testConsensus, dissensus and synergy between clinicians and specialist foundation models in radiology report generation
Source quote
L218: Flamingo-CXR (Ours) │ F + I │ \gradientcdr{0.138} │ \gradientblu{0.101} │ \textbf{\gradientrou{0.297}} │ \textbf{\gradientall{0.519}} │ \textbf{\gradienttop{0.580}} │ \gradientrad{0.205}
2023CvT-21DistillGPT2 (F + I)Radgraph F10.154Published comparison on MIMIC-CXR; FINDINGS and IMPRESSION generation. The metric accou…Consensus, dissensus and synergy between clinicians and specialist foundation models in radiology report generation
Source quote
L215: CvT-21DistillGPT2 \citep{NICOLSON2023} │ F + I │ \gradientcdr{0.361} │ \gradientblu{0.124} │ \gradientrou{0.285} │ \gradientall{0.384} │ \gradientrad{0.154}
2023METransformer non-standard sliceF10.334Clinical efficacy evaluation on MIMIC-CXR using CheXpert annotations of generated repor…R2GenGPT: Radiology Report Generation with frozen LLMs
Source quote
L185: METransformer │ 152M │ 3.62h/epo │ 0.364 │ 0.309 │ 0.334
2023R2GenCMN baselineF10.441Average row across five listed disease categories; reported in the diagnostic-accuracy …ChatCAD: Interactive Computer-Aided Diagnosis on Medical Image using Large Language Models
Source quote
L112: \multicolumn{2}{c}{Average} │ 0.312 │ 0.476 │ 0.368 │ 0.616 │ 0.382 │ 0.441 │ 0.504 │ 0.781 │ 0.591 │ {0.549} │ 0.726 │ 0.605
2023Contrastive baselineF130.6split: testLearning A Multi-Task Transformer Via Unified And Customized Instruction Tuning For Chest Radiograph Interpretation
Source quote
L76: Report generation │ MIMIC-CXR │ F1 │ 30.6\cite{liu-etal-2021-contrastive} │ 33.1 {(32.5, 33.7)}
2023R2GenRL baselineF1-Score (clinical efficacy)0.292report-section=findings · label-extractor=CheXpertNormal-Abnormal Decoupling Memory for Medical Report Generation
Source quote
L367: 0.292
2023RGRG baselineF1 score (clinical efficacy)0.447split: test · evaluation=CheXbert 14-disease-label clinical efficacyPromptMRG: Diagnosis-Driven Prompts for Medical Report Generation
Source quote
L190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details.
2023DCL baselineF1 score (clinical efficacy)0.373split: test · evaluation=CheXbert 14-disease-label clinical efficacyPromptMRG: Diagnosis-Driven Prompts for Medical Report Generation
Source quote
L190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details.
2023KiUT baselineF1 score (clinical efficacy)0.321split: test · evaluation=CheXbert 14-disease-label clinical efficacyPromptMRG: Diagnosis-Driven Prompts for Medical Report Generation
Source quote
L190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details.
2023CXR-RePaiR baselinePos F10.238split: test · method=retrieval · section=impressionPragmatic Radiology Report Generation
Source quote
L377: CXR-RePaiR │ 0.238 │ 0.368 │ 0.076 │ 0.027 │ 0.162 │ 0.028 │ 0.176 │ 0.016 │ 0.042 │ 0.756
2023Contrastive baselineF10.303split: test · input-images=single-image · label-source=CheXpertKiUT: Knowledge-injected U-Transformer for Radiology Report Generation
Source quote
L225: CXR │ Contrastive\cite{liu2021contrastive} │ 0.350 │ 0.219 │ 0.152 │ 0.109 │ 0.151 │ 0.283 │ 0.352 │ 0.298 │ 0.303
2023ChatCAD (P3) baselineF10.553split: test · llm=ChatGPT · subset=1,000 samples; five findings · retrieval-k=3ChatCAD+: Toward a Universal and Reliable Interactive CAD Using LLMs
Source quote
L308: ChatCAD (P3) │ 256M+175B │ 3.594 │ 16.791 │ 23.146 │ 0.526 │ 0.603 │ 0.553
2022Unweighted and weighted bagging models proposedF1-score0.54split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weightedEarly Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion Strategies
Source quote
L130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel.
2022Base+AP+DCA (reported as Ours) proposedROUGE-1 (R-1) F147.63split: testImproving Radiology Summarization with Radiograph and Anatomy Prompts
Source quote
L323: Ours │ 68.00 │ 59.89 │ 67.87 │ 47.63 │ 32.03 │ 46.13
2022Base+AP+DCA (reported as Ours) proposedROUGE-2 (R-2) F132.03split: testImproving Radiology Summarization with Radiograph and Anatomy Prompts
Source quote
L323: Ours │ 68.00 │ 59.89 │ 67.87 │ 47.63 │ 32.03 │ 46.13
2022Base+AP+DCA (reported as Ours) proposedROUGE-L (R-L) F146.13split: testImproving Radiology Summarization with Radiograph and Anatomy Prompts
Source quote
L323: Ours │ 68.00 │ 59.89 │ 67.87 │ 47.63 │ 32.03 │ 46.13
2022Base+graph+CL proposedROUGE-1 (R-1) F149.13Official split.Graph Enhanced Contrastive Learning for Radiology Findings Summarization
Source quote
L275: \textbf{{49.13}} │ \textbf{{33.76}} │ \textbf{{47.12}}
2022Base+graph+CL proposedROUGE-1 (R-1) F157.38split: testGraph Enhanced Contrastive Learning for Radiology Findings Summarization
Source quote
L276: 57.38 │ 45.52 │ 56.13
2022CMN (Base+cmn; table label “Ours (cmn)”) proposedF10.278split: test · beam_size=3 · images_per_patient=1Cross-modal Memory Networks for Radiology Report Generation
Source quote
L248: Ours (cmn) │ 0.353 │ 0.218 │ 0.148 │ 0.106 │ 0.142 │ 0.278 │ 0.334 │ 0.275 │ 0.278
2022Probabilistic Integration of Object Level Annotations (DenseNet121, +Gaze - EGD-CXR) proposedF10.27split: test · stage=II · backbone=DenseNet121 · annotation=EGD-CXR eye gazeProbabilistic Integration of Object Level Annotations in Chest X-ray Classification
Source quote
L176: +Gaze - EGD-CXR │ \textBF{0.836} │ \textBF{0.27}
2022Probabilistic Integration of Object Level Annotations (DenseNet121, base model) ablationF10.25split: test · stage=I · backbone=DenseNet121Probabilistic Integration of Object Level Annotations in Chest X-ray Classification
Source quote
L173: DenseNet121 │ Base model │ 0.807 │ 0.25
2022Xception base model baselineF1-score0.54split: test · fine-tuned · split-unit=patient-level · pretraining-dataset=CheXpertEarly Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion Strategies
Source quote
L126: We present the results of four different state-of-the-art CNN models tested on MIMIC-CXR and Emory-CXR in Table~\ref{tab:Base models tested on MIMIC-IV data} and Table~\ref{tab:Base models tested on Emory data} of Appendix~\ref{appendix:Basemodel}. The Xception base model yields the best AUC score (0.76), F1-score (0.54), AUPRC (0.54), and balanced accuracy (0.69) during the internal testing on MIMIC-CXR; however, the performance of the four base models is relatively similar. Further, when performing external testing on Emory-CXR, the Xception base model attains the best performance. Additionally, the performance of the Xception base model on both MIMIC-CXR and Emory-CXR is very similar, demonstrating that our fine-tuned model does not overfit on the training data. The detailed results with precision and recall are listed in Supplementary Table B1 to B2.
2022WGSum (Trans) baselineROUGE-1 (R-1) F148.37Official split. Result cited from the original paper.Graph Enhanced Contrastive Learning for Radiology Findings Summarization
Source quote
L272: WGSum (Trans) (\dagger) \cite{hu2021word} │ {61.63} │ {50.98} │ {61.73} │ {{48.37}} │ {{33.34}} │ {{46.68}} │ {56.38} │ {44.75} │ {55.32}
2022WGSum (Trans) baselineROUGE-1 (R-1) F156.38split: testGraph Enhanced Contrastive Learning for Radiology Findings Summarization
Source quote
L272: WGSum (Trans) (\dagger) \cite{hu2021word} │ {61.63} │ {50.98} │ {61.73} │ {{48.37}} │ {{33.34}} │ {{46.68}} │ {56.38} │ {44.75} │ {55.32}
2022R2Gen baselineF10.276split: test · beam_size=3 · images_per_patient=1Cross-modal Memory Networks for Radiology Report Generation
Source quote
L247: R2Gen (\ddag) │ 0.353 │ 0.218 │ 0.145 │ 0.103 │ 0.142 │ 0.277 │ 0.333 │ 0.273 │ 0.276
2021Multi-Attention w/ Contrastive Attention proposed non-standard sliceF10.303Clinical efficacy automatic evaluation using CheXpert labels for 14 thoracic disease an…Contrastive Attention for Automatic Chest X-ray Report Generation
Source quote
L301: \ w/ Contrastive Attention │ \color{red} \bf 0.352 │ \color{red} \bf 0.298 │ \color{red} \bf 0.303
2021RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard sliceMicro F1, relation extraction0.823split: test · backbone=PubMedBERT · architecture=DYGIE++RadGraph: Extracting Clinical Entities and Relations from Radiology Reports
Source quote
L175: RadGraph Benchmark │ 0.804 │ 0.861 │ 0.685 │ 0.823 │ 0.783
2021RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard sliceMicro F1, named entity recognition0.940split: test · backbone=PubMedBERT · architecture=DYGIE++RadGraph: Extracting Clinical Entities and Relations from Radiology Reports
Source quote
L157: RadGraph Benchmark │ 0.968 │ 0.922 │ 0.700 │ 0.952 │ 0.940 │ 0.886
2021R2Gen baseline non-standard sliceF10.276Clinical efficacy automatic evaluation using CheXpert labels for 14 thoracic disease an…Contrastive Attention for Automatic Chest X-ray Report Generation
Source quote
L298: R2Gen \cite{Chen2020Generating} │ 0.333 │ 0.273 │ 0.276