MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 77 of 77 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | REVTAF baseline | F1 | 0.589 | split: test | The Double Dilemma in Multi-Task Radiology Report Generation: A Gradient Dynamics Analysis and SolutionSource quoteL516: REVTAF │ ICCV'25 │ 0.615 │ 0.617 │ 0.589 │ 0.465 │ 0.319 │ 0.236 │ 0.184 │ 0.199 │ 0.336 │ 0.607 |
| 2025 | SS-ACL proposed | Clinical efficacy macro F1 | 0.505 | split: test · categories=14 thoracic diseases · test-samples=3858 · clinical-labeler=CheXbert | Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report GenerationSource quoteL453: {\color[HTML]{C00000} 0.505} |
| 2025 | DiffRGenNet proposed | F1 | 0.483 | split: test | DiffRGenNet: Difference-aware Medical Report GenerationSource quoteL286: 0.483 |
| 2025 | MedAlign proposed | F1 | 95.25% | split: test · params=7B · backbone=LLaVA-Med-1.5 7B | MedAlign: A Synergistic Framework of Multimodal Preference Optimization and Federated Meta-Cognitive ReasoningSource quoteL417: MedAlign │ 95.64 │ 96.47 │ 95.25 │ 94.36 │ 22.99 │ 27.89 │ 16.33 │ 2.29 |
| 2025 | MCA-RG (7B; listed as Ours) proposed | Example-based F1 | 0.408 | split: test · params=7B · scores=CE · averaging=example-based | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt] |
| 2025 | MCA-RG (7B; listed as Ours) proposed | Macro-based F1 | 0.335 | split: test · params=7B · scores=CE · averaging=macro-based | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt] |
| 2025 | ChexGen-balanced DenseNet121 model proposed | Weighted F1-score for worst-performing gender group | 0.387 | split: test · model=DenseNet121 · subgroup=worst-performing gender group · training-data=ChexGen-balanced | A Generative Foundation Model for Chest RadiographySource quoteL160: In addition to detecting model bias, we explored whether synthetic data could be used to further mitigate the observed bias. Using ChexGen, we generated additional training samples for underrepresented demographic subgroups until their representation matched that of the majority groups. Consequently, the augmented training data led to substantial improvements in model fairness across all demographic dimensions. For instance, the F1-Scores increased significantly for the worst group (gender: 0.338 to 0.387, race: 0.321 to 0.394, age: 0.363 to 0.419), while performance gaps between best and worst groups narrowed considerably with a relative reduction of up to 60% (gender: 2.5% to 1.6%, race: 2.9% to 1.2%, age: 2.3% to 1.2%) (\textbf{\cref{fig:figure6}d}). These results highlight the potential of CheXGen for generating synthetic data to enhance model fairness by detecting and mitigating bias. |
| 2025 | Weighted Avg (W-Avg; PRM scores) proposed | F1-CheXbert | 0.3575 | split: test · subset=full-unbalanced · strategy=weighted-average · generator=MAIRA-2 · candidates=128 · temperature=1.0 | Process Reward Models for Sentence-Level Verification of LVLM Radiology ReportsSource quoteL536: Our results (Figures~\ref{fig:bon_weighted_all} and \ref{fig:bon_nonweighted_all}) show that weighted strategies generally outperform non-weighted ones. For instance, Weighted Avg (W-Avg) using PRM scores improves F1-CheXbert by +5.0 points (0.3575 vs 0.3077 for non-weighted AvgProb) at N=128. Similarly, W-Avg boosts BERTScore by +0.001 points (0.8594 vs 0.8584) under the same conditions. The choice of N also impacts performance, with larger N generally leads to better results. |
| 2025 | KIA proposed non-standard slice | F1-Score | 0.461 | split: test · clinical-labels=14 CheXpert abnormality categories | KIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report GenerationSource quoteL477: 0.461 |
| 2025 | + Hybrid-RAG ablation | F1 | 76.68% | split: test · params=7B · variant=Hybrid-RAG · backbone=LLaVA-Med-1.5 7B | MedAlign: A Synergistic Framework of Multimodal Preference Optimization and Federated Meta-Cognitive ReasoningSource quoteL415: + Hybrid-RAG │ 78.12 │ 76.71 │ 76.68 │ 76.66 │ 15.91 │ 18.90 │ 12.82 │ 3.17 |
| 2025 | Non-weighted AvgProb (PRM-based BoN) ablation | F1-CheXbert | 0.3077 | split: test · subset=full-unbalanced · strategy=non-weighted-AvgProb · generator=MAIRA-2 · candidates=128 · temperature=1.0 | Process Reward Models for Sentence-Level Verification of LVLM Radiology ReportsSource quoteL536: Our results (Figures~\ref{fig:bon_weighted_all} and \ref{fig:bon_nonweighted_all}) show that weighted strategies generally outperform non-weighted ones. For instance, Weighted Avg (W-Avg) using PRM scores improves F1-CheXbert by +5.0 points (0.3575 vs 0.3077 for non-weighted AvgProb) at N=128. Similarly, W-Avg boosts BERTScore by +0.001 points (0.8594 vs 0.8584) under the same conditions. The choice of N also impacts performance, with larger N generally leads to better results. |
| 2025 | RA-RRG (E12) | RadGraph F1 | 26.7 | split: test | Leveraging LLMs for Multimodal Retrieval-Augmented Radiology Report Generation via Key Phrase ExtractionSource quoteL377: RA-RRG │ F │ 3,858 │ 58.5 │ 62.1 │ 41.7 │ 52.9 │ 50.7 │ 26.7 │ 3.18 │ 24.9 │ 37.9 │ 8.0 |
| 2025 | Med-PaLM M 84B | RadGraph F1 | 26.7 | split: test · params=84B | Leveraging LLMs for Multimodal Retrieval-Augmented Radiology Report Generation via Key Phrase ExtractionSource quoteL361: Med-PaLM M 84B \cite{medpalm-m} │ F │ 4,834 │ 53.6 │ 57.9 │ 39.8 │ 51.6 │ 26.7 │ 27.3 │ 32.3 │ 11.3 |
| 2025 | PromptMRG baseline | F1 (CE) | 0.476 | split: test · domain=seen | ARDGen: Augmentation Regularization for Domain-Generalized Medical Report GenerationSource quoteL284: 0.476 |
| 2025 | DCG baseline | Clinical efficacy macro F1 | 0.404 | split: test · categories=14 thoracic diseases · clinical-labeler=CheXbert | Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report GenerationSource quoteL437: {\color[HTML]{4472C4} 0.404} |
| 2025 | PromptMRG baseline | F1 | 0.476 | split: test | DiffRGenNet: Difference-aware Medical Report GenerationSource quoteL277: 0.476 |
| 2025 | WarmStart baseline | Macro-based F1 | 0.306 | split: test · scores=CE · averaging=macro-based | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL168: WarmStart\cite{warm_start} │ 2023 │ \ding{55} │ 0.418 │ 0.367 │ \multicolumn{1}{c|}{0.367} │ 0.417 │ 0.295 │ 0.306 |
| 2025 | Original biased DenseNet121 model baseline | Weighted F1-score for worst-performing gender group | 0.338 | split: test · model=DenseNet121 · subgroup=worst-performing gender group | A Generative Foundation Model for Chest RadiographySource quoteL160: In addition to detecting model bias, we explored whether synthetic data could be used to further mitigate the observed bias. Using ChexGen, we generated additional training samples for underrepresented demographic subgroups until their representation matched that of the majority groups. Consequently, the augmented training data led to substantial improvements in model fairness across all demographic dimensions. For instance, the F1-Scores increased significantly for the worst group (gender: 0.338 to 0.387, race: 0.321 to 0.394, age: 0.363 to 0.419), while performance gaps between best and worst groups narrowed considerably with a relative reduction of up to 60% (gender: 2.5% to 1.6%, race: 2.9% to 1.2%, age: 2.3% to 1.2%) (\textbf{\cref{fig:figure6}d}). These results highlight the potential of CheXGen for generating synthetic data to enhance model fairness by detecting and mitigating bias. |
| 2025 | No-rejection baseline (0% rejection) baseline | F1-CheXbert | 0.32934 | split: test · subset=full-unbalanced · generator=MAIRA-2 · rejection=none | Process Reward Models for Sentence-Level Verification of LVLM Radiology ReportsSource quoteL513: F1-CheXbert │ 0% │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 │ 0.32934 |
| 2025 | DCL baseline non-standard slice | F1-Score | 0.373 | split: test · clinical-labels=14 CheXpert abnormality categories | KIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report GenerationSource quoteL465: 0.373 |
| 2024 | FSE-1 proposed | CX14 (CheXbert micro-F1, 14 categories) | 0.470 | split: test · reference-report-truncation=M_gt=80 | Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report GenerationSource quoteL229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency. |
| 2024 | CLIP(SapBERT)+AHIVE proposed | CE(11/5) micro-average F1 | 0.678 | split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impression | AHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report RetrievalSource quoteL499: 0.678 |
| 2024 | CLIP(SapBERT)+AHIVE proposed | CE(11) micro-average F1 | 0.604 | split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impression | AHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report RetrievalSource quoteL498: 0.604 |
| 2024 | CLIP(SapBERT)+AHIVE proposed | CE(13+NL) micro-average F1 | 0.685 | split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impression | AHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report RetrievalSource quoteL500: 0.685 |
| 2024 | SGRRG proposed non-standard slice | Macro-average F1 (clinical efficacy) | 0.332 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | ChEX (VinDr-CXR and MIMIC-CXR training) proposed | Ex-F1-14 | 58.76 | split: test · 0-shot | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}} |
| 2024 | ChEX (VinDr-CXR and MIMIC-CXR training) proposed | Mic-F1-5+ | 61.03 | split: test · 0-shot | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}} |
| 2024 | ChEX (VinDr-CXR and MIMIC-CXR training) proposed | Mac-F1-5+ | 55.85 | split: test · 0-shot | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}} |
| 2024 | IVGN proposed | F1-score (CE) | 0.398 | split: test | Intensive Vision-guided Network for Radiology Report GenerationSource quoteL293: IVGN │ 0.377 │ 0.236 │ 0.158 │ 0.112 │ 0.144 │ 0.280 │ 0.415 │ 0.442 │ 0.398 |
| 2024 | MedImageInsight proposed | CheXbert Micro-avg F1-14 | 53.6 | split: test · params=0.4B | MedImageInsight: An Open-Source Embedding Model for General Domain Medical ImagingSource quoteL203: MedImageInsight\xspace \tnote{a} │ 53.6 │ 57.2 │ 37.0 │ 48.3 │ 53.3 │ 58.6 │ 40.7 │ 51.7 │ 25.5 │ 28.8 │ 37.0 │ 15.2 │ 31.6 |
| 2024 | RayDINO proposed | RadGraph F1 | 23.9 | split: test | Advancing human-centric AI for robust X-ray analysis through holistic self-supervised learningSource quoteL278: RayDINO │ 13.8\ci{13.4}{14.2} │ 30.3\ci{29.7}{30.8} │ 23.9\ci{23.3}{24.6} │ 44.8\ci{44.0}{45.6} │ 3.07\ci{3.04}{3.11} │ 36.1\ci{34.4}{37.6} │ 54.8\ci{53.5}{56.0} |
| 2024 | GenX+AC (t=0)_1 proposed | F1 score | 54.3 | split: test · backbone=ResNet-18 · auditing-component=AC · confidence-threshold=0 | Quality Control for Radiology Report Generation Models via Auxiliary Auditing ComponentsSource quoteL192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3 |
| 2024 | GenX+AC (t=0.8)_1 proposed | F1 score | 58.4 | split: test · backbone=ResNet-18 · auditing-component=AC · confidence-threshold=0.8 | Quality Control for Radiology Report Generation Models via Auxiliary Auditing ComponentsSource quoteL192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3 |
| 2024 | MAIRA-1 baseline | Mic-F1-5+ | 58.8 | split: test | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL645: MAIRA-1\cite{maira} \training{\textcolor{MidnightBlue}{M}} │ 55.7 │ -- │ 38.6 │ 58.8 │ 51.7 |
| 2024 | MAIRA-1 baseline | Mac-F1-5+ | 51.7 | split: test | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL645: MAIRA-1\cite{maira} \training{\textcolor{MidnightBlue}{M}} │ 55.7 │ -- │ 38.6 │ 58.8 │ 51.7 |
| 2024 | \textsc{\mathcal{M}^2Tr.Progressive} baseline | F1-score (CE) | 0.308 | split: test | Intensive Vision-guided Network for Radiology Report GenerationSource quoteL292: \textsc{\mathcal{M}^2Tr.Progressive} │ 0.378 │ 0.232 │ 0.154 │ 0.107 │ 0.145 │ 0.272 │ 0.240 │ 0.428 │ 0.308 |
| 2024 | GPT-4o finetune baseline | CheXbert Micro-avg F1-14 | 48.9 | split: test · fine-tuned | MedImageInsight: An Open-Source Embedding Model for General Domain Medical ImagingSource quoteL187: GPT-4o finetune\tnote{d} │ 48.9 │ 52.7 │ 33.0 │ 43.8 │ 49.3 │ 54.7 │ 36.7 │ 47.8 │ 26.4 │ 29.3 │ 39.6 │ 17.8 │ 32.1 |
| 2024 | MAIRA-1 baseline | RadGraph F1 | 22.8 | split: test | Advancing human-centric AI for robust X-ray analysis through holistic self-supervised learningSource quoteL272: \text{MAIRA-1 } │ 14.0\ci{13.6}{14.5} │ 28.5\ci{28.0}{28.9} │ 22.8\ci{22.1}{23.3} │ 42.8\ci{42.0}{43.6} │ 3.16\ci{3.13}{3.19} │ 36.7\ci{35.0}{38.2} │ 54.3\ci{53.3}{55.4} |
| 2024 | GenX (unfiltered) baseline | F1 score | 46.8 | split: test | Quality Control for Radiology Report Generation Models via Auxiliary Auditing ComponentsSource quoteL192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3 |
| 2023 | CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposed | F1-cheXbert | 76.29 | split: test · evaluation=RadSum23 public test | KU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report SummarizationSource quoteL148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96 |
| 2023 | CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposed | F1-Radgraph | 50.96 | split: test · evaluation=RadSum23 public test | KU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report SummarizationSource quoteL148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96 |
| 2023 | PromptMRG proposed | F1 score (clinical efficacy) | 0.476 | split: test · evaluation=CheXbert 14-disease-label clinical efficacy | PromptMRG: Diagnosis-Driven Prompts for Medical Report GenerationSource quoteL190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details. |
| 2023 | Pragmatic LLaMA proposed | Pos F1 | 0.307 | split: test · fine-tuned · epochs=3 · section=impression · training-examples=18264 | Pragmatic Radiology Report GenerationSource quoteL383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158 |
| 2023 | Pragmatic Retrieval proposed | Neg F1-5 | 0.156 | split: test · section=impression · metric-subset=five most frequent negative labels | Pragmatic Radiology Report GenerationSource quoteL382: Pragmatic Retrieval │ 0.293 │ 0.403 │ 0.103 │ 0.072 │ -0.103 │ 0.078 │ -0.084 │ \bf 0.077 │ \bf 0.156 │ 0.445 |
| 2023 | Pragmatic LLaMA proposed | Neg F1-5 | 0.127 | split: test · fine-tuned · epochs=3 · section=impression · metric-subset=five most frequent negative labels · training-examples=18264 | Pragmatic Radiology Report GenerationSource quoteL383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158 |
| 2023 | KiUT proposed | F1 | 0.321 | split: test · input-images=single-image · label-source=CheXpert | KiUT: Knowledge-injected U-Transformer for Radiology Report GenerationSource quoteL229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321 |
| 2023 | Proposed longitudinal model with sentence-anatomy dropout proposed | F1 (CE) | 0.553 | split: test · report_scope=full · prior_cxr_input=enabled · sentence_anatomy_dropout=enabled | Controllable Chest X-Ray Report Generation from Longitudinal RepresentationsSource quoteL363: 0.553 |
| 2023 | Proposed longitudinal model with sentence-anatomy dropout proposed non-standard slice | F1 (CE) | 0.672 | split: test · report_scope=partial · prior_cxr_input=enabled · sentence_anatomy_dropout=enabled | Controllable Chest X-Ray Report Generation from Longitudinal RepresentationsSource quoteL486: 0.672 |
| 2023 | DCL (row “Ours”) proposed | F1-score | 0.373 | split: test · labels=CheXpert 14 medical terminologies · evaluation=clinical efficacy | Dynamic Graph Enhanced Contrastive Learning for Chest X-ray Report GenerationSource quoteL205: Ours │ 0.471 │ 0.352 │ 0.373 |
| 2023 | ORGan proposed | F1 (F_1; clinical efficacy) | 0.385 | split: test · labeler=CheXpert · evaluation=clinical-efficacy | ORGAN: Observation-Guided Radiology Report Generation via Tree ReasoningSource quoteL241: \multirow{4}{*}{\textsc{\makecell{MIMIC\\-CXR}}} │ ORGan │ {0.407} │ {0.256} │ {0.172} │ {0.123} │ {0.162} │ {0.293} │ {0.416} │ {0.418} │ {0.385} |
| 2023 | ChatCAD+ (P3) proposed | F1 | 0.564 | split: test · llm=ChatGPT · subset=1,000 samples; five findings · retrieval-k=3 | ChatCAD+: Toward a Universal and Reliable Interactive CAD Using LLMsSource quoteL311: ChatCAD+ (P3) │ 256M+175B │ 4.409 │ 17.344 │ 24.337 │ 0.531 │ 0.615 │ 0.564 |
| 2023 | PromptMRG ablation baseline (no added modules) ablation | F1 score (clinical efficacy) | 0.370 | split: test · evaluation=CheXbert 14-disease-label clinical efficacy · configuration=baseline only | PromptMRG: Diagnosis-Driven Prompts for Medical Report GenerationSource quoteL195: To verify the effectiveness of each module, we do ablation study on MIMIC test set, which is shown in Table 2. Firstly, we see that the baseline only achieves fair CE performance (e.g., a F1 score of 0.370). By adding DDP, the F1 score increases significantly to 0.444, indicating the effectiveness of DDP in producing diagnostically correct reports. Adding auxiliary disease labeling (ADL) also benefits CE results, improves F1 score to 0.451. When CFE and SDL are further applied, the F1 score improves to 0.464 and 0.468, respectively. Finally, utilizing all the modules yields the best F1 score of 0.476. We notice that ADL and CFE improve both precision and recall while SDL is more helpful for recall. We believe this is related to the mechanism of SDL, which encourages the learning of less-learned diseases on recalling positive cases. On the other hand, the usage of DDP degrades the NLG performance by about 0.8% on average. Through an examination of the N-gram statistics of the generated reports (see Appendix), we have noted that the baseline is more likely to repeat the frequent phrases from the training set in comparison to the model that utilizes DDP. We suspect it is because DDP provides extra diagnostic information during the generation process, making the generated texts more diverse and less susceptible to high-frequency phrases. Consequently, the NLG performance would exhibit a decline with DDP, as a result of fewer matched phrases. When CFE and SDL are further added, the NLG performance increases, but still lags behind the baseline (except for BLEU-1). Overall, the proposed modules substantially improve the CE performance at the expense of slightly degraded NLG performance. |
| 2023 | PromptMRG ablation baseline with DDP ablation | F1 score (clinical efficacy) | 0.444 | split: test · evaluation=CheXbert 14-disease-label clinical efficacy · configuration=baseline plus DDP | PromptMRG: Diagnosis-Driven Prompts for Medical Report GenerationSource quoteL195: To verify the effectiveness of each module, we do ablation study on MIMIC test set, which is shown in Table 2. Firstly, we see that the baseline only achieves fair CE performance (e.g., a F1 score of 0.370). By adding DDP, the F1 score increases significantly to 0.444, indicating the effectiveness of DDP in producing diagnostically correct reports. Adding auxiliary disease labeling (ADL) also benefits CE results, improves F1 score to 0.451. When CFE and SDL are further applied, the F1 score improves to 0.464 and 0.468, respectively. Finally, utilizing all the modules yields the best F1 score of 0.476. We notice that ADL and CFE improve both precision and recall while SDL is more helpful for recall. We believe this is related to the mechanism of SDL, which encourages the learning of less-learned diseases on recalling positive cases. On the other hand, the usage of DDP degrades the NLG performance by about 0.8% on average. Through an examination of the N-gram statistics of the generated reports (see Appendix), we have noted that the baseline is more likely to repeat the frequent phrases from the training set in comparison to the model that utilizes DDP. We suspect it is because DDP provides extra diagnostic information during the generation process, making the generated texts more diverse and less susceptible to high-frequency phrases. Consequently, the NLG performance would exhibit a decline with DDP, as a result of fewer matched phrases. When CFE and SDL are further added, the NLG performance increases, but still lags behind the baseline (except for BLEU-1). Overall, the proposed modules substantially improve the CE performance at the expense of slightly degraded NLG performance. |
| 2023 | Flamingo-CXR (F + I) | CheXpert F1 (all) | 0.519 | split: test | Consensus, dissensus and synergy between clinicians and specialist foundation models in radiology report generationSource quoteL218: Flamingo-CXR (Ours) │ F + I │ \gradientcdr{0.138} │ \gradientblu{0.101} │ \textbf{\gradientrou{0.297}} │ \textbf{\gradientall{0.519}} │ \textbf{\gradienttop{0.580}} │ \gradientrad{0.205} |
| 2023 | Flamingo-CXR (F + I) | Radgraph F1 | 0.205 | split: test | Consensus, dissensus and synergy between clinicians and specialist foundation models in radiology report generationSource quoteL218: Flamingo-CXR (Ours) │ F + I │ \gradientcdr{0.138} │ \gradientblu{0.101} │ \textbf{\gradientrou{0.297}} │ \textbf{\gradientall{0.519}} │ \textbf{\gradienttop{0.580}} │ \gradientrad{0.205} |
| 2023 | Contrastive baseline | F1 | 30.6 | split: test | Learning A Multi-Task Transformer Via Unified And Customized Instruction Tuning For Chest Radiograph InterpretationSource quoteL76: Report generation │ MIMIC-CXR │ F1 │ 30.6\cite{liu-etal-2021-contrastive} │ 33.1 {(32.5, 33.7)} |
| 2023 | RGRG baseline | F1 score (clinical efficacy) | 0.447 | split: test · evaluation=CheXbert 14-disease-label clinical efficacy | PromptMRG: Diagnosis-Driven Prompts for Medical Report GenerationSource quoteL190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details. |
| 2023 | DCL baseline | F1 score (clinical efficacy) | 0.373 | split: test · evaluation=CheXbert 14-disease-label clinical efficacy | PromptMRG: Diagnosis-Driven Prompts for Medical Report GenerationSource quoteL190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details. |
| 2023 | KiUT baseline | F1 score (clinical efficacy) | 0.321 | split: test · evaluation=CheXbert 14-disease-label clinical efficacy | PromptMRG: Diagnosis-Driven Prompts for Medical Report GenerationSource quoteL190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details. |
| 2023 | CXR-RePaiR baseline | Pos F1 | 0.238 | split: test · method=retrieval · section=impression | Pragmatic Radiology Report GenerationSource quoteL377: CXR-RePaiR │ 0.238 │ 0.368 │ 0.076 │ 0.027 │ 0.162 │ 0.028 │ 0.176 │ 0.016 │ 0.042 │ 0.756 |
| 2023 | Contrastive baseline | F1 | 0.303 | split: test · input-images=single-image · label-source=CheXpert | KiUT: Knowledge-injected U-Transformer for Radiology Report GenerationSource quoteL225: CXR │ Contrastive\cite{liu2021contrastive} │ 0.350 │ 0.219 │ 0.152 │ 0.109 │ 0.151 │ 0.283 │ 0.352 │ 0.298 │ 0.303 |
| 2023 | ChatCAD (P3) baseline | F1 | 0.553 | split: test · llm=ChatGPT · subset=1,000 samples; five findings · retrieval-k=3 | ChatCAD+: Toward a Universal and Reliable Interactive CAD Using LLMsSource quoteL308: ChatCAD (P3) │ 256M+175B │ 3.594 │ 16.791 │ 23.146 │ 0.526 │ 0.603 │ 0.553 |
| 2022 | Unweighted and weighted bagging models proposed | F1-score | 0.54 | split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weighted | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel. |
| 2022 | Base+AP+DCA (reported as Ours) proposed | ROUGE-1 (R-1) F1 | 47.63 | split: test | Improving Radiology Summarization with Radiograph and Anatomy PromptsSource quoteL323: Ours │ 68.00 │ 59.89 │ 67.87 │ 47.63 │ 32.03 │ 46.13 |
| 2022 | Base+AP+DCA (reported as Ours) proposed | ROUGE-2 (R-2) F1 | 32.03 | split: test | Improving Radiology Summarization with Radiograph and Anatomy PromptsSource quoteL323: Ours │ 68.00 │ 59.89 │ 67.87 │ 47.63 │ 32.03 │ 46.13 |
| 2022 | Base+AP+DCA (reported as Ours) proposed | ROUGE-L (R-L) F1 | 46.13 | split: test | Improving Radiology Summarization with Radiograph and Anatomy PromptsSource quoteL323: Ours │ 68.00 │ 59.89 │ 67.87 │ 47.63 │ 32.03 │ 46.13 |
| 2022 | Base+graph+CL proposed | ROUGE-1 (R-1) F1 | 57.38 | split: test | Graph Enhanced Contrastive Learning for Radiology Findings SummarizationSource quoteL276: 57.38 │ 45.52 │ 56.13 |
| 2022 | CMN (Base+cmn; table label “Ours (cmn)”) proposed | F1 | 0.278 | split: test · beam_size=3 · images_per_patient=1 | Cross-modal Memory Networks for Radiology Report GenerationSource quoteL248: Ours (cmn) │ 0.353 │ 0.218 │ 0.148 │ 0.106 │ 0.142 │ 0.278 │ 0.334 │ 0.275 │ 0.278 |
| 2022 | Probabilistic Integration of Object Level Annotations (DenseNet121, +Gaze - EGD-CXR) proposed | F1 | 0.27 | split: test · stage=II · backbone=DenseNet121 · annotation=EGD-CXR eye gaze | Probabilistic Integration of Object Level Annotations in Chest X-ray ClassificationSource quoteL176: +Gaze - EGD-CXR │ \textBF{0.836} │ \textBF{0.27} |
| 2022 | Probabilistic Integration of Object Level Annotations (DenseNet121, base model) ablation | F1 | 0.25 | split: test · stage=I · backbone=DenseNet121 | Probabilistic Integration of Object Level Annotations in Chest X-ray ClassificationSource quoteL173: DenseNet121 │ Base model │ 0.807 │ 0.25 |
| 2022 | Xception base model baseline | F1-score | 0.54 | split: test · fine-tuned · split-unit=patient-level · pretraining-dataset=CheXpert | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL126: We present the results of four different state-of-the-art CNN models tested on MIMIC-CXR and Emory-CXR in Table~\ref{tab:Base models tested on MIMIC-IV data} and Table~\ref{tab:Base models tested on Emory data} of Appendix~\ref{appendix:Basemodel}. The Xception base model yields the best AUC score (0.76), F1-score (0.54), AUPRC (0.54), and balanced accuracy (0.69) during the internal testing on MIMIC-CXR; however, the performance of the four base models is relatively similar. Further, when performing external testing on Emory-CXR, the Xception base model attains the best performance. Additionally, the performance of the Xception base model on both MIMIC-CXR and Emory-CXR is very similar, demonstrating that our fine-tuned model does not overfit on the training data. The detailed results with precision and recall are listed in Supplementary Table B1 to B2. |
| 2022 | WGSum (Trans) baseline | ROUGE-1 (R-1) F1 | 56.38 | split: test | Graph Enhanced Contrastive Learning for Radiology Findings SummarizationSource quoteL272: WGSum (Trans) (\dagger) \cite{hu2021word} │ {61.63} │ {50.98} │ {61.73} │ {{48.37}} │ {{33.34}} │ {{46.68}} │ {56.38} │ {44.75} │ {55.32} |
| 2022 | R2Gen baseline | F1 | 0.276 | split: test · beam_size=3 · images_per_patient=1 | Cross-modal Memory Networks for Radiology Report GenerationSource quoteL247: R2Gen (\ddag) │ 0.353 │ 0.218 │ 0.145 │ 0.103 │ 0.142 │ 0.277 │ 0.333 │ 0.273 │ 0.276 |
| 2021 | RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard slice | Micro F1, relation extraction | 0.823 | split: test · backbone=PubMedBERT · architecture=DYGIE++ | RadGraph: Extracting Clinical Entities and Relations from Radiology ReportsSource quoteL175: RadGraph Benchmark │ 0.804 │ 0.861 │ 0.685 │ 0.823 │ 0.783 |
| 2021 | RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard slice | Micro F1, named entity recognition | 0.940 | split: test · backbone=PubMedBERT · architecture=DYGIE++ | RadGraph: Extracting Clinical Entities and Relations from Radiology ReportsSource quoteL157: RadGraph Benchmark │ 0.968 │ 0.922 │ 0.700 │ 0.952 │ 0.940 │ 0.886 |
| 2021 | Radiologist Benchmark baseline | Micro F1, relation extraction | 0.947 | split: test · reference=radiologist benchmark | RadGraph: Extracting Clinical Entities and Relations from Radiology ReportsSource quoteL174: Radiologist Benchmark │ 0.952 │ 0.949 │ 0.830 │ 0.947 │ 0.910 |
| 2020 | R2Gen baseline | Micro Average F1 | 34.6 | split: test | Improving Factual Completeness and Consistency of Image-to-Text Radiology Report GenerationSource quoteL664: (2713 / 654) │ F_1 │ 34.6 │ 54.9 │ 56.7 │ 56.7 │ 21.1 │ 47.2 │ 48.3 │ 47.8 |