MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 77 of 77 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | FairLLaVA-All proposed | Age-group RadGraph-F1 fairness gap | 5.60 | Age-group gap; evaluation aggregates over subgroups of the other demographic attributes… | FairLLaVA: Fairness-Aware Parameter-Efficient Fine-Tuning for Large Vision-Language AssistantsSource quoteL680: 0.59 │ 1.01 │ 5.60 │ 12.29 |
| 2026 | LePaX proposed | RadGraph F1 (RG_F1) | 0.346 | Clinical metric evaluation on MIMIC-CXR. | Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report GenerationSource quoteL439: 0.346 |
| 2026 | DiTPO proposed | F1 | 0.516 | data_setting=full-data | Rethinking the Efficiency and Effectiveness of Reinforcement Learning for Radiology Report GenerationSource quoteL233: Table \ref{table:mimic_results} details the comparative results on the MIMIC-CXR. Our DiTPO model with full-data establishes a new SOTA in clinical accuracy, achieving a F1 score of 0.516. This performance surpasses our basic GRPO framework (0.507) and previous leading RL methods like OISA (0.504), as well as strong SFT baselines such as SS-ACL (0.505), validating the effectiveness of directly optimizing for diagnostic entities. |
| 2026 | LLaVA-TA proposed | RadGraph F1 | 31.1 | fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · evaluation_setting=in-distribution | Rethinking Radiology Report Generation: From Narrative Flow to Topic-Guided FindingsSource quoteL601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs. |
| 2026 | ESC-RL proposed | F1 | 0.608 | Clinical efficacy (CE) comparison across 14 diseases; split not specified in the cited … | Enhancing Reinforcement Learning for Radiology Report Generation with Evidence-aware Rewards and Self-correcting Preference LearningSource quoteL317: ESC-RL (Ours) │ 0.632 │ 0.625 │ 0.608 │ 0.299 │ 0.311 │ 0.295 |
| 2025 | SS-ACL proposed | Clinical efficacy macro F1 | 0.505 | split: test · categories=14 thoracic diseases · test-samples=3858 · clinical-labeler=CheXbert | Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report GenerationSource quoteL453: {\color[HTML]{C00000} 0.505} |
| 2025 | MedAlign proposed | RadGraph F1 | 10.92 | peft · backbone=LLaVA-Med-1.5 · fine-tuning=without LoRA | Enhancing Medical Large Vision-Language Models via Alignment DistillationSource quoteL441: MedAlign\xspace │ 4.51 │ 18.43 │ 20.80 │ 86.00 │ 25.67 │ 10.92 │ 42.03 |
| 2025 | AM-MRG proposed | F1 | 0.484 | Clinical Efficacy (CE) metric on MIMIC-CXR; split and averaging are not specified in th… | Activating Associative Disease-Aware Vision Token Memory for LLM-Based X-Ray Report GenerationSource quoteL349: As depicted in Tables \ref{tab:CE_Metrics_Mimic_CXR_results} and \ref{tab:CE_Metrics_CheXpert_Plus_results}, we have evaluated the accuracy of our model, AM-MRG, in delineating clinical abnormalities by reporting the Clinical Efficacy (CE) metrics alongside seven other models across two distinct datasets. On the MIMIC-CXR dataset, AM-MRG yielded impressive results with Precision, Recall, and F1 scores of 0.555, 0.429, and 0.484, respectively. Notably, the Recall and F1 scores surpass those of the competing models, with the F1 score a remarkable 19.5% higher than the second-best model, CoFE~\cite{li2025CoFE}. In the Chexpert Plus dataset, AM-MRG took the lead in all three metrics, achieving Precision, Recall, and F1 scores of 0.396, 0.318, and 0.336, respectively. The F1 score represented a significant 16.6% improvement over the runner-up, Token-Mixer~\cite{Yang2024Token-Mixer}, signifying a substantial edge. |
| 2025 | DiffRGenNet proposed | F1 | 0.483 | split: test | DiffRGenNet: Difference-aware Medical Report GenerationSource quoteL286: 0.483 |
| 2025 | MedAlign proposed | F1 | 95.25% | split: test · params=7B · backbone=LLaVA-Med-1.5 7B | MedAlign: A Synergistic Framework of Multimodal Preference Optimization and Federated Meta-Cognitive ReasoningSource quoteL417: MedAlign │ 95.64 │ 96.47 │ 95.25 │ 94.36 │ 22.99 │ 27.89 │ 16.33 │ 2.29 |
| 2025 | CURV proposed | RadGraph F1 | 19.54 | params=3B | CURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report GenerationSource quoteL277: 19.54 |
| 2025 | MedOrch proposed | Macro F1-score | 25.5% | Chest X-ray analysis; macro-level metric. | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteL4: Healthcare decision-making represents one of the most challenging domains for Artificial Intelligence (AI), requiring the integration of diverse knowledge sources, complex reasoning, and various external analytical tools. Current AI systems often rely on either task-specific models, which offer limited adaptability, or general language models without grounding with specialized external knowledge and tools. We introduce \texttt{MedOrch}\xspace, a novel framework that orchestrates multiple specialized tools and reasoning agents to provide comprehensive medical decision support. \texttt{MedOrch}\xspace employs a modular, agent-based architecture that facilitates the flexible integration of domain-specific tools without altering the core system. Furthermore, it ensures transparent and traceable reasoning processes, enabling clinicians to meticulously verify each intermediate step underlying the system’s recommendations. We evaluate \texttt{MedOrch}\xspace across three distinct medical applications: Alzheimer's disease diagnosis, chest X-ray interpretation, and medical visual question answering, using authentic clinical datasets. The results demonstrate \texttt{MedOrch}\xspace's competitive performance across these diverse medical tasks. Notably, in Alzheimer's disease diagnosis, \texttt{MedOrch}\xspace achieves an accuracy of 93.26%, surpassing the state-of-the-art baseline by over four percentage points. For predicting Alzheimer's disease progression, it attains a 50.35% accuracy, marking a significant improvement. In chest X-ray analysis, \texttt{MedOrch}\xspace exhibits superior performance with a Macro AUC of 61.2% and a Macro F1-score of 25.5%. Moreover, in complex multimodal visual question answering (Image+Table), \texttt{MedOrch}\xspace achieves an accuracy of 54.47%. These findings underscore \texttt{MedOrch}\xspace's potential to advance healthcare AI by enabling reasoning-driven tool utilization for multimodal medical data processing and supporting intricate cognitive tasks in clinical decision-making. |
| 2025 | MCA-RG (7B; listed as Ours) proposed | Example-based F1 | 0.408 | split: test · params=7B · scores=CE · averaging=example-based | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt] |
| 2025 | MCA-RG (7B; listed as Ours) proposed | Macro-based F1 | 0.335 | split: test · params=7B · scores=CE · averaging=macro-based | MCA-RG: Enhancing LLMs with Medical Concept Alignment for Radiology Report GenerationSource quoteL172: Ours │ 7B │ 0.472 │ 0.406 │ \multicolumn{1}{c|}{0.408} │ 0.443 │ 0.306 │ 0.335 [1.1pt] |
| 2025 | ChexGen-balanced DenseNet121 model proposed | Weighted F1-score for worst-performing gender group | 0.387 | split: test · model=DenseNet121 · subgroup=worst-performing gender group · training-data=ChexGen-balanced | A Generative Foundation Model for Chest RadiographySource quoteL160: In addition to detecting model bias, we explored whether synthetic data could be used to further mitigate the observed bias. Using ChexGen, we generated additional training samples for underrepresented demographic subgroups until their representation matched that of the majority groups. Consequently, the augmented training data led to substantial improvements in model fairness across all demographic dimensions. For instance, the F1-Scores increased significantly for the worst group (gender: 0.338 to 0.387, race: 0.321 to 0.394, age: 0.363 to 0.419), while performance gaps between best and worst groups narrowed considerably with a relative reduction of up to 60% (gender: 2.5% to 1.6%, race: 2.9% to 1.2%, age: 2.3% to 1.2%) (\textbf{\cref{fig:figure6}d}). These results highlight the potential of CheXGen for generating synthetic data to enhance model fairness by detecting and mitigating bias. |
| 2025 | MAIRA-2 + CCD proposed | RadGraph-F1 | 19.01 | Radiology report generation; CCD applied to MAIRA-2. | CCD: Mitigating Hallucinations in Radiology MLLMs via Clinical Contrastive DecodingSource quoteL478: \(+\) CCD │ 20.70 │ 2.10 │ 51.62 │ 19.01 │ 17.58 │ 53.32 │ 17.50 │ 27.05 │ 16.02 |
| 2025 | OTDRG proposed | Clinical efficacy F1 | 0.436 | disease-labels=14 · clinical-labeler=CheXbert | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | CoCa-CXR, description-only generation proposed | RadGraph F1 | 24.2% | Generates descriptions only; CoCa-CXR and the compared models rely solely on images as … | CoCa-CXR: Contrastive Captioners Learn Strong Temporal Structures for Chest X-Ray Vision-Language UnderstandingSource quoteL127: Tab.~\ref{tab:mimic-cxr} presents report generation results on the MIMIC-CXR dataset \cite{johnson2019mimic}. CoCa-CXR predicts both FINDINGS and IMPRESSION sections, a more challenging task than FINDINGS alone \cite{bannur2023learning}. When generating only descriptions, it achieves a RadGraph F1 score of 24.2%, on par with large-scale models like Med-Gemini \cite{yang2024advancing}. Notably, PaliGemma-2 \cite{steiner2024paligemma} incorporates both images and the indication section as inputs, whereas CoCa-CXR and other models in Tab.~\ref{tab:mimic-cxr} rely solely on images; hence, we exclude its result for fair comparison. |
| 2025 | CoCa-CXR, generating comparison descriptions proposed | RadGraph F1 | 23.7% | Generates comparison descriptions in addition to descriptions. | CoCa-CXR: Contrastive Captioners Learn Strong Temporal Structures for Chest X-Ray Vision-Language UnderstandingSource quoteL128: When also generating comparison descriptions, CoCa-CXR attains a RadGraph F1 score of 23.7%. Although this is slightly lower than description-only generation, our hypothesis is that, describing progression adds another dimension to report generation tasks, and with the current accuracy-level (65%) on temporal classification, one can obtain a similar level of benefit on Radgraph F1 by simply omitting comparisons in the generated reports. But still, as shown in Fig. \ref{fig:pos_vs_neg_order}, this is step forward in incorporating this progression dimension and towards real world application. |
| 2025 | RADAR proposed | RG-F1 | 0.346 | view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384 | RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge InjectionSource quoteL224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports. |
| 2025 | RADAR proposed | 14-observation macro-average F1 | 0.460 | backbone=BLIP-3 · beam-width=5 · resolution=384×384 | RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge InjectionSource quoteL288: (14)Macro Average │ 0.481 │ 0.474 │ 0.460 |
| 2025 | RADAR proposed | 5-observation macro-average F1 | 0.567 | backbone=BLIP-3 · beam-width=5 · resolution=384×384 | RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge InjectionSource quoteL276: ^5Macro Average │ 0.551 │ 0.602 │ 0.567 |
| 2025 | Weighted Avg (W-Avg; PRM scores) proposed | F1-CheXbert | 0.3575 | split: test · subset=full-unbalanced · strategy=weighted-average · generator=MAIRA-2 · candidates=128 · temperature=1.0 | Process Reward Models for Sentence-Level Verification of LVLM Radiology ReportsSource quoteL536: Our results (Figures~\ref{fig:bon_weighted_all} and \ref{fig:bon_nonweighted_all}) show that weighted strategies generally outperform non-weighted ones. For instance, Weighted Avg (W-Avg) using PRM scores improves F1-CheXbert by +5.0 points (0.3575 vs 0.3077 for non-weighted AvgProb) at N=128. Similarly, W-Avg boosts BERTScore by +0.001 points (0.8594 vs 0.8584) under the same conditions. The choice of N also impacts performance, with larger N generally leads to better results. |
| 2025 | MLRG proposed | micro avg F1 | 0.505 | Clinical accuracy across 14 CheXpert-annotated observations; micro average. The cited t… | Enhanced Contrastive Learning with Multi-view Longitudinal Data for Chest X-ray Report GenerationSource quoteL259: micro avg │ 0.523 │ 0.410 │ 0.460 │ 0.549 │ 0.468 │ 0.505 │ 0.522 │ 0.447 │ 0.481 │ 0.532 │ 0.474 │ 0.501 |
| 2025 | KIA proposed non-standard slice | F1-Score | 0.461 | split: test · clinical-labels=14 CheXpert abnormality categories | KIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report GenerationSource quoteL477: 0.461 |
| 2025 | EMRRG proposed | F1 | 0.395 | fine-tuned | EMRRG: Efficient Fine-Tuning Pre-trained X-ray Mamba Networks for Radiology Report GenerationSource quoteL208: EMRRG │ Ours │ 0.421 │ 0.372 │ 0.395 |
| 2024 | FSE-1 proposed | CX14 (CheXbert micro-F1, 14 categories) | 0.470 | split: test · reference-report-truncation=M_gt=80 | Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report GenerationSource quoteL229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency. |
| 2024 | EVOKE (multi-view; Stage 1 fact-serialization alignment with MPC, G, and L; Stage 2 indication and bridge enabled) proposed | F1 RadGraph (RG) | 0.276 | resolution=224×224 | MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report GenerationSource quoteL180: EVOKE │ M │ F │ \ding{51} │ \ding{51} │ \ding{51} │ \ding{51} (\ding{51}) │ 0.262 │ 0.147 │ 0.167 │ 0.311 │ 0.276 │ 0.557 │ 0.499 |
| 2024 | CLIP(SapBERT)+AHIVE proposed | CE(11/5) micro-average F1 | 0.678 | split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impression | AHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report RetrievalSource quoteL499: 0.678 |
| 2024 | CLIP(SapBERT)+AHIVE proposed | CE(11) micro-average F1 | 0.604 | split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impression | AHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report RetrievalSource quoteL498: 0.604 |
| 2024 | CLIP(SapBERT)+AHIVE proposed | CE(13+NL) micro-average F1 | 0.685 | split: test · runs=3-run average · backbone=CLIP · description=three-level; five anatomical parts · target-report=findings/impression | AHIVE: Anatomy-Aware Hierarchical Vision Encoding for Interactive Radiology Report RetrievalSource quoteL500: 0.685 |
| 2024 | Libra proposed | Macro-F1-5 | 53.8% | CheXpert F1 for the five most common findings; concurrent-work comparison, with differi… | Libra: Leveraging Temporal Images for Biomedical Radiology AnalysisSource quoteL583: Macro-F1-5 │ -- │ -- │ 51.5 │ 49.5 │ 53.8 (4.5%) |
| 2024 | SGRRG proposed non-standard slice | Macro-average F1 (clinical efficacy) | 0.332 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | TRRG full configuration (BASE + DCI + CMCI + DAL) proposed | F1 | 0.393 | Full ablation configuration: DCI, CMCI, and DAL added to BASE; split not specified in t… | TRRG: Towards Truthful Radiology Report Generation With Cross-modal Disease Clue Enhanced Large Language ModelSource quoteL248: 4 │ \multicolumn{1}{l|}{+DCI+CMCI+DAL} │ 0.151 │ 0.377 │ 0.209 │ 0.405 │ 0.157 │ 0.336 │ 0.167 │ 0.219 │ 0.393 |
| 2024 | ChEX (VinDr-CXR and MIMIC-CXR training) proposed | Ex-F1-14 | 58.76 | split: test · 0-shot | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}} |
| 2024 | ChEX (VinDr-CXR and MIMIC-CXR training) proposed | Mic-F1-5+ | 61.03 | split: test · 0-shot | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}} |
| 2024 | ChEX (VinDr-CXR and MIMIC-CXR training) proposed | Mac-F1-5+ | 55.85 | split: test · 0-shot | ChEX: Interactive Localization and Region Description in Chest X-RaysSource quoteL636: ChEX \training{\textcolor{OliveGreen}{V}}\training{\textcolor{MidnightBlue}{M}} │ 52.32\std{0.51} │ \textbf{58.76\std{0.42}} │ 32.56\std{0.51} │ \textbf{61.03\std{0.56}} │ \textbf{55.85\std{0.57}} |
| 2024 | Ours (pathology-aware regional prompts; PARP) proposed | F1-score | 0.470 | Automated clinical-efficacy metric; compared with state-of-the-art report-generation me… | Anatomy-Guided Radiology Report Generation with Pathology-Aware Regional PromptsSource quoteL397: 0.470 \Xhline{1pt} |
| 2024 | Teaser proposed | F1-score | 0.526 | Clinical-efficacy metric over 14 disease categories; split and averaging details are no… | Topicwise Separable Sentence Retrieval for Medical Report GenerationSource quoteL317: Specifically, our Precision metric increases from 0.501 to 0.534, Recall increases from 0.509 to 0.518, and F1-score increases from 0.476 to 0.526. |
| 2024 | IVGN proposed | F1-score (CE) | 0.398 | split: test | Intensive Vision-guided Network for Radiology Report GenerationSource quoteL293: IVGN │ 0.377 │ 0.236 │ 0.158 │ 0.112 │ 0.144 │ 0.280 │ 0.415 │ 0.442 │ 0.398 |
| 2024 | LM-RRG proposed | F1 | 0.484 | Main comparison table; clinical efficacy metric. Split not stated. | Large Model driven Radiology Report Generation with Clinical Quality Reinforcement LearningSource quoteL193: LM-RRG(Ours) │ 0.122 │ 0.165 │ 0.296 │ 0.500 │ 0.500 │ 0.484 │ 0.865 |
| 2024 | MedImageInsight proposed | CheXbert Micro-avg F1-14 | 53.6 | split: test · params=0.4B | MedImageInsight: An Open-Source Embedding Model for General Domain Medical ImagingSource quoteL203: MedImageInsight\xspace \tnote{a} │ 53.6 │ 57.2 │ 37.0 │ 48.3 │ 53.3 │ 58.6 │ 40.7 │ 51.7 │ 25.5 │ 28.8 │ 37.0 │ 15.2 │ 31.6 |
| 2024 | MedCycle {CheXpert} proposed | F1 | 0.183 | Clinical efficacy on MIMIC-CXR; images from CheXpert and reports from MIMIC-CXR for tra… | MedCycle: Unpaired Medical Report Generation via Cycle-ConsistencySource quoteL349: MedCycle {CheXpert} │ 0.230 │ 0.171 │ 0.183 |
| 2024 | MedCycle {Xlate} proposed | F1 | 0.198 | Clinical efficacy on MIMIC-CXR; images from PadChest and reports from MIMIC-CXR for tra… | MedCycle: Unpaired Medical Report Generation via Cycle-ConsistencySource quoteL351: MedCycle {Xlate} │ 0.218 │ 0.209 │ 0.198 |
| 2024 | CoFE (+ \mathcal{L}-CF, full) proposed | F1-score | 0.405 | Clinical efficacy evaluation on MIMIC-CXR. | Contrastive Learning with Counterfactual Explanations for Radiology Report GenerationSource quoteL173: + \mathcal{L}-CF (full) │ 0.489 │ 0.370 │ 0.405 |
| 2024 | DCRRG proposed | clinical efficacy F1 | 0.376 | Clinical-efficacy evaluation on MIMIC-CXR; disease labels are extracted from reports. | Divide and Conquer Radiology Report Generation via Observation Level Fine-grained Pretraining and Prompt TuningSource quoteL287: 0.376 |
| 2024 | RayDINO proposed | RadGraph F1 | 23.9 | split: test | Advancing human-centric AI for robust X-ray analysis through holistic self-supervised learningSource quoteL278: RayDINO │ 13.8\ci{13.4}{14.2} │ 30.3\ci{29.7}{30.8} │ 23.9\ci{23.3}{24.6} │ 44.8\ci{44.0}{45.6} │ 3.07\ci{3.04}{3.11} │ 36.1\ci{34.4}{37.6} │ 54.8\ci{53.5}{56.0} |
| 2024 | GenX+AC (t=0)_1 proposed | F1 score | 54.3 | split: test · backbone=ResNet-18 · auditing-component=AC · confidence-threshold=0 | Quality Control for Radiology Report Generation Models via Auxiliary Auditing ComponentsSource quoteL192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3 |
| 2024 | GenX+AC (t=0.8)_1 proposed | F1 score | 58.4 | split: test · backbone=ResNet-18 · auditing-component=AC · confidence-threshold=0.8 | Quality Control for Radiology Report Generation Models via Auxiliary Auditing ComponentsSource quoteL192: Average │ 54.1 │ 46.8 │ 54.3 │ 58.4 │ 41.6 │ 42.3 |
| 2024 | Llama 3.1 Instruct-8B (9,000-sample joint training) proposed | micro-F1 | 0.67 | fine-tuned · params=8B · label-source=NegBio-derived · training-samples=9000 | Enhancing disease detection in radiology reports through fine-tuning lightweight LLM on weak labelsSource quoteL210: 9,000 │ 6,000 │ 3,000 │ 0.62 │ 0.72 │ 0.67 │ 0.44 │ 0.83 │ 0.58 |
| 2023 | ChatCAD (Ours, ChatGPT) proposed | F1 | 0.605 | prompt=Prompt#3 | ChatCAD: Interactive Computer-Aided Diagnosis on Medical Image using Large Language ModelsSource quoteL112: \multicolumn{2}{c}{Average} │ 0.312 │ 0.476 │ 0.368 │ 0.616 │ 0.382 │ 0.441 │ 0.504 │ 0.781 │ 0.591 │ {0.549} │ 0.726 │ 0.605 |
| 2023 | ChatCAD (Ours, GPT-3) proposed | F1 | 0.591 | prompt=Prompt#3 | ChatCAD: Interactive Computer-Aided Diagnosis on Medical Image using Large Language ModelsSource quoteL112: \multicolumn{2}{c}{Average} │ 0.312 │ 0.476 │ 0.368 │ 0.616 │ 0.382 │ 0.441 │ 0.504 │ 0.781 │ 0.591 │ {0.549} │ 0.726 │ 0.605 |
| 2023 | XproNet + ITHN proposed non-standard slice | F1 | 0.317 | Clinical efficacy metric on MIMIC-CXR; generated reports are labeled with a CheXpert-tr… | Automatic Radiology Report Generation by Learning with Increasingly Hard NegativesSource quoteL215: XproNet + \textbf{\text{ITHN}} │ 0.362 │ 0.283 │ 0.317 │ 0.82 |
| 2023 | CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposed | F1-cheXbert | 76.29 | split: test · evaluation=RadSum23 public test | KU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report SummarizationSource quoteL148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96 |
| 2023 | CheXOFA (KU-DMIS-MSRA; leaderboard row “ku-dmis-msra (Ours)”) proposed | F1-Radgraph | 50.96 | split: test · evaluation=RadSum23 public test | KU-DMIS-MSRA at RadSum23: Pre-trained Vision-Language Model for Radiology Report SummarizationSource quoteL148: ku-dmis-msra (Ours) │ 25.58 │ 47.75 │ 64.80 │ 76.29 │ 50.96 |
| 2023 | PromptMRG proposed | F1 score (clinical efficacy) | 0.476 | split: test · evaluation=CheXbert 14-disease-label clinical efficacy | PromptMRG: Diagnosis-Driven Prompts for Medical Report GenerationSource quoteL190: We compare our model with SOTA methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, and RGRG~\cite{TMK23}. Table 1 shows the results on both MIMIC-CXR and IU X-Ray. We can see from the table that the proposed method achieves SOTA performance on the three CE metrics on both datasets and outperforms most existing methods by a large margin. For example, our method obtains 0.476 F1 score on MIMIC, which shows a 10% absolute improvement over a recent work DCL (0.373 F1) and 15% over KiUT (0.321 F1). Even compared with the best existing method RGRG (0.447 F1), the absolute improvement is 2.9%. Similarly, on IU X-Ray, PromptMRG outperforms other methods considerably, where its absolute improvement over the best existing method RGRG is 3.1%. As for NLG metrics, our method is also competitive. For example, PromptMRG achieves the best results on all the NLG metrics of IU and the best BLEU-1 on MIMIC. However, the performance of our method on the other NLG metrics of MIMIC is not as good as that of IU. We suspect it is caused by DDP, as we found that model without DDP tends to generate more frequent phrases from the training data than the one with DDP, especially for long reports (MIMIC is about two times longer than IU on average). As a result, the former will achieve better NLG performance than the latter, as NLG metrics evaluate language consistency between predictions and references by utilizing word matching. See Ablation Study below and N-gram Statistics in the Appendix for more details. |
| 2023 | Pragmatic LLaMA proposed | Pos F1 | 0.307 | split: test · fine-tuned · epochs=3 · section=impression · training-examples=18264 | Pragmatic Radiology Report GenerationSource quoteL383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158 |
| 2023 | Pragmatic Retrieval proposed | Neg F1-5 | 0.156 | split: test · section=impression · metric-subset=five most frequent negative labels | Pragmatic Radiology Report GenerationSource quoteL382: Pragmatic Retrieval │ 0.293 │ 0.403 │ 0.103 │ 0.072 │ -0.103 │ 0.078 │ -0.084 │ \bf 0.077 │ \bf 0.156 │ 0.445 |
| 2023 | Pragmatic LLaMA proposed | Neg F1-5 | 0.127 | split: test · fine-tuned · epochs=3 · section=impression · metric-subset=five most frequent negative labels · training-examples=18264 | Pragmatic Radiology Report GenerationSource quoteL383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158 |
| 2023 | KiUT proposed | F1 | 0.321 | split: test · input-images=single-image · label-source=CheXpert | KiUT: Knowledge-injected U-Transformer for Radiology Report GenerationSource quoteL229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321 |
| 2023 | Proposed longitudinal model with sentence-anatomy dropout proposed | F1 (CE) | 0.553 | split: test · report_scope=full · prior_cxr_input=enabled · sentence_anatomy_dropout=enabled | Controllable Chest X-Ray Report Generation from Longitudinal RepresentationsSource quoteL363: 0.553 |
| 2023 | Proposed longitudinal model with sentence-anatomy dropout proposed non-standard slice | F1 (CE) | 0.672 | split: test · report_scope=partial · prior_cxr_input=enabled · sentence_anatomy_dropout=enabled | Controllable Chest X-Ray Report Generation from Longitudinal RepresentationsSource quoteL486: 0.672 |
| 2023 | DCL (row “Ours”) proposed | F1-score | 0.373 | split: test · labels=CheXpert 14 medical terminologies · evaluation=clinical efficacy | Dynamic Graph Enhanced Contrastive Learning for Chest X-ray Report GenerationSource quoteL205: Ours │ 0.471 │ 0.352 │ 0.373 |
| 2023 | ORGan proposed | F1 (F_1; clinical efficacy) | 0.385 | split: test · labeler=CheXpert · evaluation=clinical-efficacy | ORGAN: Observation-Guided Radiology Report Generation via Tree ReasoningSource quoteL241: \multirow{4}{*}{\textsc{\makecell{MIMIC\\-CXR}}} │ ORGan │ {0.407} │ {0.256} │ {0.172} │ {0.123} │ {0.162} │ {0.293} │ {0.416} │ {0.418} │ {0.385} |
| 2023 | ChatCAD+ (P3) proposed | F1 | 0.564 | split: test · llm=ChatGPT · subset=1,000 samples; five findings · retrieval-k=3 | ChatCAD+: Toward a Universal and Reliable Interactive CAD Using LLMsSource quoteL311: ChatCAD+ (P3) │ 256M+175B │ 4.409 │ 17.344 │ 24.337 │ 0.531 │ 0.615 │ 0.564 |
| 2023 | R2GenGPT (Deep) proposed non-standard slice | F1 | 0.389 | Clinical efficacy evaluation on MIMIC-CXR using CheXpert annotations of generated repor… | R2GenGPT: Radiology Report Generation with frozen LLMsSource quoteL184: Deep │ \checkmark │ \checkmark │ 90.9M │ 2.75h/epo │ 0.392 │ 0.387 │ 0.389 |
| 2022 | Unweighted and weighted bagging models proposed | F1-score | 0.54 | split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weighted | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel. |
| 2022 | Base+AP+DCA (reported as Ours) proposed | ROUGE-1 (R-1) F1 | 47.63 | split: test | Improving Radiology Summarization with Radiograph and Anatomy PromptsSource quoteL323: Ours │ 68.00 │ 59.89 │ 67.87 │ 47.63 │ 32.03 │ 46.13 |
| 2022 | Base+AP+DCA (reported as Ours) proposed | ROUGE-2 (R-2) F1 | 32.03 | split: test | Improving Radiology Summarization with Radiograph and Anatomy PromptsSource quoteL323: Ours │ 68.00 │ 59.89 │ 67.87 │ 47.63 │ 32.03 │ 46.13 |
| 2022 | Base+AP+DCA (reported as Ours) proposed | ROUGE-L (R-L) F1 | 46.13 | split: test | Improving Radiology Summarization with Radiograph and Anatomy PromptsSource quoteL323: Ours │ 68.00 │ 59.89 │ 67.87 │ 47.63 │ 32.03 │ 46.13 |
| 2022 | Base+graph+CL proposed | ROUGE-1 (R-1) F1 | 49.13 | Official split. | Graph Enhanced Contrastive Learning for Radiology Findings SummarizationSource quoteL275: \textbf{{49.13}} │ \textbf{{33.76}} │ \textbf{{47.12}} |
| 2022 | Base+graph+CL proposed | ROUGE-1 (R-1) F1 | 57.38 | split: test | Graph Enhanced Contrastive Learning for Radiology Findings SummarizationSource quoteL276: 57.38 │ 45.52 │ 56.13 |
| 2022 | CMN (Base+cmn; table label “Ours (cmn)”) proposed | F1 | 0.278 | split: test · beam_size=3 · images_per_patient=1 | Cross-modal Memory Networks for Radiology Report GenerationSource quoteL248: Ours (cmn) │ 0.353 │ 0.218 │ 0.148 │ 0.106 │ 0.142 │ 0.278 │ 0.334 │ 0.275 │ 0.278 |
| 2022 | Probabilistic Integration of Object Level Annotations (DenseNet121, +Gaze - EGD-CXR) proposed | F1 | 0.27 | split: test · stage=II · backbone=DenseNet121 · annotation=EGD-CXR eye gaze | Probabilistic Integration of Object Level Annotations in Chest X-ray ClassificationSource quoteL176: +Gaze - EGD-CXR │ \textBF{0.836} │ \textBF{0.27} |
| 2021 | Multi-Attention w/ Contrastive Attention proposed non-standard slice | F1 | 0.303 | Clinical efficacy automatic evaluation using CheXpert labels for 14 thoracic disease an… | Contrastive Attention for Automatic Chest X-ray Report GenerationSource quoteL301: \ w/ Contrastive Attention │ \color{red} \bf 0.352 │ \color{red} \bf 0.298 │ \color{red} \bf 0.303 |
| 2021 | RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard slice | Micro F1, relation extraction | 0.823 | split: test · backbone=PubMedBERT · architecture=DYGIE++ | RadGraph: Extracting Clinical Entities and Relations from Radiology ReportsSource quoteL175: RadGraph Benchmark │ 0.804 │ 0.861 │ 0.685 │ 0.823 │ 0.783 |
| 2021 | RadGraph Benchmark (DYGIE++ with PubMedBERT initializations) proposed non-standard slice | Micro F1, named entity recognition | 0.940 | split: test · backbone=PubMedBERT · architecture=DYGIE++ | RadGraph: Extracting Clinical Entities and Relations from Radiology ReportsSource quoteL157: RadGraph Benchmark │ 0.968 │ 0.922 │ 0.700 │ 0.952 │ 0.940 │ 0.886 |