MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 2 of 2 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | MedAlign proposed | RadGraph F1 | 10.92 | peft · backbone=LLaVA-Med-1.5 · fine-tuning=without LoRA | Enhancing Medical Large Vision-Language Models via Alignment DistillationSource quoteL441: MedAlign\xspace │ 4.51 │ 18.43 │ 20.80 │ 86.00 │ 25.67 │ 10.92 │ 42.03 |
| 2025 | A^3Tune baseline | RadGraph F1 | 10.52 | peft · backbone=LLaVA-Med-1.5 · fine-tuning=without LoRA | Enhancing Medical Large Vision-Language Models via Alignment DistillationSource quoteL440: A^3Tune │ 4.22 │ 18.02 │ 20.69 │ 85.75 │ 25.37 │ 10.52 │ 42.15 |