MIMIC-CXR

263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

68.772.676.580.32024M-FLAG: 69.5 (2023)DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained): 79.53 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 11 of 11 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026LLaVA-TA proposedRadGraph F131.1fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · evaluation_setting=in-distributionRethinking Radiology Report Generation: From Narrative Flow to Topic-Guided Findings
Source quote
L601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs.
2026LLaVA-T ablationRadGraph F11.6fine-tuned · LLM=frozen · fine-tuning=MLP-only · vision_encoder=frozen · anatomical_masks=excluded · evaluation_setting=in-distributionRethinking Radiology Report Generation: From Narrative Flow to Topic-Guided Findings
Source quote
L601: LLaVA-T and LLaVA-Rad. For instance, on MIMIC-CXR, LLaVA-TA achieves a RadGraph F1 of 31.1, whereas LLaVA-T and LLaVA-Rad lag far behind at 1.6 and 19.8, respectively. This suggests that when the LLM’s parameters are frozen, the explicit spatial cues from the anatomical masks are vital. They provide a strong, structured signal that helps the lightweight MLP learn to map visual regions to the LLM’s latent space effectively. This finding points to a promising direction for efficiently adapting large, frozen VLMs to the medical domain by using structured visual inputs.
2025EMRRG proposedF10.395fine-tunedEMRRG: Efficient Fine-Tuning Pre-trained X-ray Mamba Networks for Radiology Report Generation
Source quote
L208: EMRRG │ Ours │ 0.421 │ 0.372 │ 0.395
2025RadFM with V-RAG and no listed fine-tuning tasks ablationF10.721fine-tunedReducing Hallucinations of Medical Multimodal Large Language Models with Visual Retrieval-Augmented Generation
Source quote
L336: 0.721 │ 0.920
2024Llama 3.1 Instruct-8B (9,000-sample joint training) proposedmicro-F10.67fine-tuned · params=8B · label-source=NegBio-derived · training-samples=9000Enhancing disease detection in radiology reports through fine-tuning lightweight LLM on weak labels
Source quote
L210: 9,000 │ 6,000 │ 3,000 │ 0.62 │ 0.72 │ 0.67 │ 0.44 │ 0.83 │ 0.58
2024GPT-4o finetune baselineCheXbert Micro-avg F1-1448.9split: test · fine-tunedMedImageInsight: An Open-Source Embedding Model for General Domain Medical Imaging
Source quote
L187: GPT-4o finetune\tnote{d} │ 48.9 │ 52.7 │ 33.0 │ 43.8 │ 49.3 │ 54.7 │ 36.7 │ 47.8 │ 26.4 │ 29.3 │ 39.6 │ 17.8 │ 32.1
2024NegBio baselinemicro-F10.63fine-tuned · method-type=rule-basedEnhancing disease detection in radiology reports through fine-tuning lightweight LLM on weak labels
Source quote
L212: NegBio │ 0.82 │ 0.51 │ 0.63
2023Pragmatic LLaMA proposedPos F10.307split: test · fine-tuned · epochs=3 · section=impression · training-examples=18264Pragmatic Radiology Report Generation
Source quote
L383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158
2023Pragmatic LLaMA proposedNeg F1-50.127split: test · fine-tuned · epochs=3 · section=impression · metric-subset=five most frequent negative labels · training-examples=18264Pragmatic Radiology Report Generation
Source quote
L383: Pragmatic LLaMA │ \bf 0.307 │ \bf 0.417 │ \bf 0.194 │ \bf 0.137 │ \bf 0.360 │ \bf 0.151 │ \bf 0.385 │ 0.050 │ 0.127 │ \bf 0.158
2022Unweighted and weighted bagging models proposedF1-score0.54split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weightedEarly Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion Strategies
Source quote
L130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel.
2022Xception base model baselineF1-score0.54split: test · fine-tuned · split-unit=patient-level · pretraining-dataset=CheXpertEarly Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion Strategies
Source quote
L126: We present the results of four different state-of-the-art CNN models tested on MIMIC-CXR and Emory-CXR in Table~\ref{tab:Base models tested on MIMIC-IV data} and Table~\ref{tab:Base models tested on Emory data} of Appendix~\ref{appendix:Basemodel}. The Xception base model yields the best AUC score (0.76), F1-score (0.54), AUPRC (0.54), and balanced accuracy (0.69) during the internal testing on MIMIC-CXR; however, the performance of the four base models is relatively similar. Further, when performing external testing on Emory-CXR, the Xception base model attains the best performance. Additionally, the performance of the Xception base model on both MIMIC-CXR and Emory-CXR is very similar, demonstrating that our fine-tuned model does not overfit on the training data. The detailed results with precision and recall are listed in Supplementary Table B1 to B2.