| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 101 of 101 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | DRRG proposed | BLEU-4 | 0.210 | denoising-steps=72 · sequence-length=100 | DRRG: A Discrete Diffusion Framework for Radiology Report GenerationSource quoteL355: NLG Metrics: The NLG results on MIMIC-CXR and CheXpert Plus are reported in Table~\ref{tab:mimic_nlg} and Table~\ref{tab:chex_plus}. On MIMIC-CXR, DRRG achieves the best performance on BLEU-2, BLEU-3, BLEU-4, and ROUGE-L, with scores of 0.332, 0.259, 0.210, and 0.343, respectively. It also obtains the second-best BLEU-1 score of 0.452, slightly behind REVTAF-RRG~\cite{zhou2025learnable}. Compared with recent LLM-based RRG methods, DRRG achieves stronger NLG performance with a substantially smaller 0.6B text decoder, whereas the listed LLM-based competitors use text decoders with 7B or more parameters. On CheXpert Plus, DRRG achieves the best BLEU-4 score and a competitive ROUGE-L of 0.265. These results demonstrate the effectiveness of DRRG, suggesting that DLLMs provide a strong alternative to conventional AR-based RRG models. |
| 2026 | LePaX proposed | BLEU-4 | 0.253 | Report-generation evaluation; the paper reports BLEU-4 / METEOR / ROUGE in that order. | Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report GenerationSource quoteL341: On MIMIC-CXR, it achieves BLEU-4 / METEOR / ROUGE scores of 0.253 / 0.336 / 0.380, surpassing previous encoder–decoder, transformer, and LLM-based methods. |
| 2026 | RIHA (Report-Image Hierarchical Alignment Transformer) proposed | BLEU-1 | 0.385 | Reported benchmark result for RIHA on MIMIC-CXR; the split is not specified in the cite… | RIHA: Report-Image Hierarchical Alignment for Radiology Report GenerationSource quoteL146: On the more challenging MIMIC-CXR dataset, RIHA demonstrates competitive results, achieving the best scores in BLEU-1 (0.385), BLEU-2 (0.251), METEOR (0.159), and ROUGE-L (0.293). Our method shows consistent improvements over recent approaches including M2KT~\cite{yang2023radiology} (4.6% improvement on BLEU-1), CAMANET~\cite{wang2024camanet} (4.9% improvement on BLEU-1), and COMG~\cite{gu2024complex} (11.6% improvement on BLEU-1). |
| 2026 | BoxMed-RL | BLEU-3 | 0.185 | Downstream chest X-ray report generation; report target is the findings section; MIMIC-… | Reason like a radiologist: Chain-of-thought and reinforcement learning for verifiable report generationSource quoteL798: BoxMed-RL demonstrates significant performance in NLG metrics, achieving state-of-the-art performance in BLEU-3 and BLEU-4 scores across two datasets: MIMIC-CXR (0.185 and 0.134, Table 1) and IU Xray (0.240 and 0.178, Table 2). It also yields an average improvement of 7 % in both METEOR and ROUGE-L, metrics that emphasize semantic adequacy and content coverage. These consistent gains on external datasets not included in pretraining underscore the robustness and generalizability of our framework. |
| 2026 | BoxMed-RL | BLEU-4 | 0.134 | Downstream chest X-ray report generation; report target is the findings section; MIMIC-… | Reason like a radiologist: Chain-of-thought and reinforcement learning for verifiable report generationSource quoteL798: BoxMed-RL demonstrates significant performance in NLG metrics, achieving state-of-the-art performance in BLEU-3 and BLEU-4 scores across two datasets: MIMIC-CXR (0.185 and 0.134, Table 1) and IU Xray (0.240 and 0.178, Table 2). It also yields an average improvement of 7 % in both METEOR and ROUGE-L, metrics that emphasize semantic adequacy and content coverage. These consistent gains on external datasets not included in pretraining underscore the robustness and generalizability of our framework. |
| 2025 | GPT-4o, Thought Graph Traversal (TGT) proposed | BLEU-4 | 9.84% | split: test · backbone=GPT-4o | Simple Radiology VLLM Test-time Scaling with Thought Graph TraversalSource quoteL200: TGT │ 29.25 │ 15.81 │ 8.95 │ 9.84 │ 14.12 │ 26.50 |
| 2025 | HuatuoGPT-Vision, Thought Graph Traversal (TGT) proposed | BLEU-4 | 11.34% | split: test · backbone=HuatuoGPT-Vision | Simple Radiology VLLM Test-time Scaling with Thought Graph TraversalSource quoteL208: TGT │ 32.99 │ 18.89 │ 10.85 │ 11.34 │ 14.36 │ 27.06 |
| 2025 | MedUnifier (w TIG) proposed | BLEU-1 (BL-1) | 41.5 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MedUnifier (w TIG) proposed | BLEU-4 (BL-4) | 12.9 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | SS-ACL proposed | BLEU-4 | 0.144 | split: test · test-samples=3858 | Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report GenerationSource quoteL447: {\color[HTML]{C00000} 0.144} |
| 2025 | AM-MRG proposed | BLEU-4 | 0.136 | NLG report-generation metric on MIMIC-CXR; split and averaging are not specified in the… | Activating Associative Disease-Aware Vision Token Memory for LLM-Based X-Ray Report GenerationSource quoteL344: In the MIMIC-CXR dataset, AM-MRG secures the best results for all metrics except CIDEr, with scores of 0.426 for BLEU-1, 0.271 for BLEU-2, 0.187 for BLEU-3, 0.136 for BLEU-4, 0.291 for ROUGE-L, and 0.174 for METEOR. Additionally, BLEU-4 has improved by 8.8% relative to R2GenGPT~\cite{Wang2023R2GenGPT}. |
| 2025 | CURV proposed | BLEU-3 (B-3) | 9.85 | params=3B | CURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report GenerationSource quoteL210: 9.85 |
| 2025 | OTDRG proposed | BLEU-1 | 0.411 | Report-generation comparison table; table states results are from the original papers. | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | OTDRG proposed | BLEU-4 | 0.128 | Report-generation comparison table; table states results are from the original papers. | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | RADAR proposed | BLEU-1 | 0.509 | view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384 | RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge InjectionSource quoteL224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports. |
| 2025 | KIA proposed | BLEU-4 | 0.138 | split: test | KIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report GenerationSource quoteL535: Specifically, our KIA achieves 0.188 and 0.138 |
| 2025 | MediVLM proposed | BLEU-4 | 0.059 | unsupervised | MediVLM: A Vision Language Model for Radiology Report Generation from Medical ImagesSource quoteL486: 0.059 |
| 2025 | Gemini-2.5-pro (SOTA VLM thinking model) non-standard slice | BLEU-1 | 27.68 | Automated report generation on a representative 500-case subset; Original versus Vision… | VisionCAD: An Integration-Free Radiology Copilot FrameworkSource quoteL260: BLEU-1 │ 25.88 │ 25.17 │ 27.68 │ 27.84 |
| 2025 | Gemini-2.5-pro (SOTA VLM thinking model) non-standard slice | BLEU-1 | 27.84 | Automated report generation on a representative 500-case subset; Original versus Vision… | VisionCAD: An Integration-Free Radiology Copilot FrameworkSource quoteL260: BLEU-1 │ 25.88 │ 25.17 │ 27.68 │ 27.84 |
| 2025 | I3 + C2FD baseline | BLEU-1 | 0.402 | Descriptive report-generation score on the official MIMIC-CXR split; no averaging proto… | DART: Disease-aware Image-Text Alignment and Self-correcting Re-alignment for Trustworthy Radiology Report GenerationSource quoteL116: I3 + C2FD~\cite{liu2024bootstrapping} │ 0.402 │ 0.262 │ 0.180 │ 0.128 │ 0.291 │ 0.175 |
| 2025 | MAIRA-2 baseline | BLEU-3 (B-3) | 9.01 | Radiology report generation; reported as the directly compared baseline for CURV. | CURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report GenerationSource quoteL170: 9.01 |
| 2025 | BLIP-3 (longitudinal) baseline | Bleu-4 | 0.184 | split: test · input=current and prior findings · subset=2,461 frontal-view pairs | A Review of Longitudinal Radiology Report Generation: Dataset Composition, Methods, and Performance EvaluationSource quoteL596: Model performance was evaluated using the Bleu-4 and METEOR metrics. On 2,461 frontal-view pairs from the MIMIC-CXR test set, the longitudinal BLIP-3 achieved a Bleu-4 score of 0.184 and a METEOR score of 0.428, slightly outperforming the single-image BLIP-3 (0.088 and 0.306, respectively). |
| 2025 | BLIP-3 (single-image) baseline | Bleu-4 | 0.088 | split: test · input=single image · subset=2,461 frontal-view pairs | A Review of Longitudinal Radiology Report Generation: Dataset Composition, Methods, and Performance EvaluationSource quoteL596: Model performance was evaluated using the Bleu-4 and METEOR metrics. On 2,461 frontal-view pairs from the MIMIC-CXR test set, the longitudinal BLIP-3 achieved a Bleu-4 score of 0.184 and a METEOR score of 0.428, slightly outperforming the single-image BLIP-3 (0.088 and 0.306, respectively). |
| 2024 | FSE-1 proposed | BL-1 (BLEU-1) | 0.397 | split: test · reference-report-truncation=M_gt=80 | Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report GenerationSource quoteL229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency. |
| 2024 | EVOKE (multi-view; Stage 1 fact-serialization alignment with MPC, G, and L; Stage 2 indication and bridge enabled) proposed | BLEU-4 (B-4) | 0.147 | resolution=224×224 | MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report GenerationSource quoteL180: EVOKE │ M │ F │ \ding{51} │ \ding{51} │ \ding{51} │ \ding{51} (\ding{51}) │ 0.262 │ 0.147 │ 0.167 │ 0.311 │ 0.276 │ 0.557 │ 0.499 |
| 2024 | WoLF proposed | BLEU-1 | 0.496 | Report generation; official MIMIC-CXR split. | WoLF: Wide-scope Large Language Model Framework for CXR UnderstandingSource quoteL171: WoLF{} │ 0.496 │ 0.517 │ 0.335 │ 0.366 │ 0.233 │ 0.261 │ 0.165 │ 0.199 │ 0.187 │ 0.412 │ 0.370 │ 0.456 |
| 2024 | Libra proposed | BLEU-1 | 51.3% | Concurrent-work comparison; the compared models' inference sets differ, and some use su… | Libra: Leveraging Temporal Images for Biomedical Radiology AnalysisSource quoteL570: BLEU-1 │ 39.2 │ -- │ 46.5 │ 33.9 │ 51.3 (10.3%) |
| 2024 | Libra proposed | BLEU-4 | 24.5% | Concurrent-work comparison; the compared models' inference sets differ, and some use su… | Libra: Leveraging Temporal Images for Biomedical Radiology AnalysisSource quoteL571: BLEU-4 │ 14.8 │ 17.8 │ 23.4 │ 10.3 │ 24.5 (4.7%) |
| 2024 | FITA proposed | BLEU-1 | 0.411 | split: test | FITA: Fine-grained Image-Text Aligner for Radiology Report GenerationSource quoteL107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326 |
| 2024 | SGRRG proposed | BLEU-1 | 0.434 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | SGRRG proposed | BLEU-4 | 0.149 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | Ours (pathology-aware regional prompts; PARP) proposed | BLEU-1 | 0.394 | Automated natural language generation metric; compared with state-of-the-art report-gen… | Anatomy-Guided Radiology Report Generation with Pathology-Aware Regional PromptsSource quoteL388: 0.394 |
| 2024 | R2GenCSR (Llama2 text decoder) proposed | BLEU-4 | 0.136 | decoder=Llama2 | R2GenCSR: Retrieving Context Samples for Large Language Model based X-ray Medical Report GenerationSource quoteL345: As shown in Table~\ref{tab:results_iu_mimic}, we report our results on the large-scale MIMIC-CXR dataset. Our method achieved a BLEU-1 score of 0.420, a BLEU-4 score of 0.136, and a ROUGE-L score of 0.291, indicating its ability to generate precise and contextually relevant medical reports. The CIDEr score of 0.267 suggests that the method produces descriptive reports that closely match the reference summaries, highlighting its practical application in clinical settings. Note that our approach employs a dataset-specific strategy, utilizing Llama2 as the text decoder, which is the model variant optimized for the MIMIC-CXR dataset, ensuring that the model is well-suited to the medical reports it processes. Notably, as illustrated in Table~\ref{tab:Clinical_Efficacy_Metrics}, our method achieves competitive CE scores for the MIMIC-CXR dataset, highlighting the robustness of our model in handling imbalanced datasets by effectively capturing relationships in both major and minor categories. |
| 2024 | MedCycle {CheXpert} proposed | B-1 (BLEU-1) | 0.309 | MIMIC-CXR evaluation; images from CheXpert and reports from MIMIC-CXR for training; no … | MedCycle: Unpaired Medical Report Generation via Cycle-ConsistencySource quoteL286: MedCycle {CheXpert} │ 0.309 │ 0.167 │ 0.098 │ 0.061 │ 0.115 │ 0.216 │ 0.461 │ 0.290 │ 0.201 │ 0.143 │ 0.182 │ 0.332 \\[0.01in] |
| 2024 | MedCycle {PadChest} proposed | B-1 (BLEU-1) | 0.349 | MIMIC-CXR evaluation; images from PadChest and reports from MIMIC-CXR for training. Pad… | MedCycle: Unpaired Medical Report Generation via Cycle-ConsistencySource quoteL288: MedCycle {PadChest} │ 0.349 │ 0.195 │ 0.115 │ 0.072 │ 0.128 │ 0.239 │ 0.479 │ 0.291 │ 0.198 │ 0.140 │ 0.197 │ 0.360 \\[0.01in] |
| 2024 | DMMCS (InstructBLIP) proposed non-standard slice | BLEU | 13.39 | subset=ground-truth tags · backbone=InstructBLIP | A Data-Driven Guided Decoding Mechanism for Diagnostic CaptioningSource quoteL385: InstructBLIP │ 12.76 │ 13.39 │ 14.35 │ 16.27 │ 24.65 │ 25.61 |
| 2024 | Memory Alignment Network (MA; proposed model) proposed | BLEU-1 | 0.396 | split: test | Automatic Radiology Reports Generation via Memory Alignment NetworkSource quoteL254: 0.396 |
| 2024 | Ablation (a), direct Stage-2-only multi-view configuration (indication and bridge enabled) ablation | BLEU-4 (B-4) | 0.134 | resolution=224×224 | MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report GenerationSource quoteL170: (a) │ M │ \ding{55} │ \ding{55} │ \ding{55} │ \ding{51} (\ding{51}) │ 0.247 │ 0.134 │ 0.158 │ 0.296 │ 0.252 │ 0.545 │ 0.480 |
| 2024 | KGAE {CheXpert} | B-1 (BLEU-1) | 0.221 | MIMIC-CXR evaluation; images from CheXpert for training. The comparison setup is descri… | MedCycle: Unpaired Medical Report Generation via Cycle-ConsistencySource quoteL285: KGAE {CheXpert} │ 0.221 │ 0.144 │ 0.096 │ 0.062 │ 0.097 │ 0.208 │ 0.417 │ 0.263 │ 0.181 │ 0.126 │ 0.149 │ 0.318 |
| 2024 | RadFound | BLEU-4 | 0.114 | Radiological report generation; reports include findings and impression sections and ar… | Expert-level vision-language foundation model for real-world radiology and comprehensive evaluationSource quoteL74: Radiological report benchmarks typically feature longer text lengths and contain more professional and detailed descriptions. Here, RadFound was evaluated for its synthesis skills in generating radiological text. On the IU-Xray dataset, RadFound achieved ROUGE-L and BLEU-4 scores of 0.357 and 0.186 respectively, while the baseline model achieved 0.294 and 0.125. On the MIMIC-CXR dataset, RadFound achieved ROUGE-L of 0.306 and BLEU-4 of 0.114, outperforming the baseline model, which obtained noticeably lower scores of 0.219 and 0.050, respectively (Fig. 3d). The excellent performance indicates that RadFound has developed proficient text generation capabilities, including the generation of longer and more complex radiological reports. Additionally, on the MIMIC-CXR dataset, we evaluated the clinical efficacy26, which measures the accuracy of descriptions for clinical abnormalities across diseases, such as pneumonia and edema (Supplementary Figure |
| 2024 | GPT-4o, Prompt 1.1 Basic baseline | BLEU-4 | 0.031 | prompt=basic direct generation · section=findings | GPT-4V Cannot Generate Radiology Reports YetSource quoteL701: 1.1 │ 0.331 │ 0.031 │ 0.225 │ 0.282 │ 0.134 │ 0.153 │ 0.163 │ 0.244 │ 0.418 │ 0.421 |
| 2024 | GPT-4-vision-preview (gt conditions) baseline | BLEU-4 | 0.007 | section=impression · condition-input=ground-truth conditions | GPT-4V Cannot Generate Radiology Reports YetSource quoteL879: GPT-4V (gt) │ 0.176 │ 0.007 │ 0.185 │ 0.179 │ 0.885 │ \bf 0.977 │ 0.103 │ 0.584 │ \bf 0.958 │ \bf 0.431 |
| 2024 | Finetuned LLaMA-2 (gt conditions) baseline | BLEU-4 | 0.094 | fine-tuned · params=7B · section=impression · backbone=LLaMA-2-7B · condition-input=ground-truth conditions | GPT-4V Cannot Generate Radiology Reports YetSource quoteL880: LLaMA-2 (gt) │ \bf 0.301 │ \bf 0.094 │ \bf 0.330 │ \bf 0.348 │ \bf 0.923 │ 0.957 │ \bf 0.286 │ \bf 0.703 │ 0.941 │ 0.710 |
| 2024 | + DPO baseline | BL-1 (BLEU) | 29.61 | split: test · backbone=LLaVA-Med v1.5 | MMedPO: Aligning Medical Vision-Language Models with Clinical-Aware Multimodal Preference OptimizationSource quoteL367: + DPO │ 41.63 │ 15.13 │ 5.56 │ 2.03 │ 12.95 │ 17.13 │ 29.61 │ 10.29 │ 3.61 │ 1.27 │ 9.45 │ 7.81 |
| 2024 | TransSQ baseline | BLEU-1 | 0.423 | Report-generation comparison; table values quoted from published literature; WoLF evalu… | WoLF: Wide-scope Large Language Model Framework for CXR UnderstandingSource quoteL167: TransSQ~\cite{transsq} │ 0.423 │ 0.484 │ 0.261 │ 0.333 │ 0.171 │ 0.238 │ 0.116 │ 0.175 │ 0.168 │ 0.207 │ 0.286 │ 0.415 |
| 2024 | KiUT baseline | BLEU-1 | 0.393 | split: test | FITA: Fine-grained Image-Text Aligner for Radiology Report GenerationSource quoteL105: KiUT~\cite{huang2023kiut} │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321 |
| 2024 | CvT-212DistilGPT2 baseline | BLEU-1 | 0.372 | MIMIC-CXR report generation; non-dagger comparison on the study's preprocessed dataset. | HERGen: Elevating Radiology Report Generation with Longitudinal DataSource quoteL285: CvT-212DistilGPT2~\cite{nicolson2023improving} │ 2022 │ 0.372 │ 0.231 │ 0.155 │ 0.111 │ 0.149 │ 0.280 │ 0.417 │ 0.295 │ 0.306 |
| 2024 | RECAP baseline | BLEU-4 | 12.5% | Report generation; MIMIC-CXR evaluation. | Has multimodal learning delivered universal intelligence in healthcare? A comprehensive surveySource quoteL833: However, these models are still constrained by the data bias inherent in current datasets, which impairs their ability to detect and accurately describe subtle anomalies. On the MIMIC-ABN dataset~\cite{ni-etal-2020-learning}, which exclusively contains anomaly descriptions from the MIMIC-CXR dataset, the performance of these models on various metrics is significantly degraded~\cite{ni-etal-2020-learning, DBLP:conf/emnlp/HouCXLL23}. For instance, the BLEU-4 and ROUGE scores of RECAP~\cite{DBLP:conf/emnlp/HouCXLL23} on MIMIC-CXR are 12.5% and 28.8%, respectively, while on MIMIC-ABN, they drop to 8% and 22.3%, respectively. Furthermore, these models often overlook individual variability and the influence of patient-specific clinical context on diagnostic conclusions. This lack of consideration for personalized clinical information limits the overall effectiveness and accuracy of the generated reports. |
| 2024 | R2Gen baseline | BLEU-1 | 0.350 | Main comparison; original baseline, compared with R2Gen + TISR. Metric label follows th… | Textual Inversion and Self-supervised Refinement for Radiology Report GenerationSource quoteL108: R2Gen\textsuperscript{*}~\cite{ref-33} │ 0.350 │ 0.214 │ 0.143 │ 0.103 │ 0.135 │ 0.271 │ 0.424 │ 0.254 │ 0.317 |
| 2024 | R2Gen + TISR baseline | BLEU-1 | 0.358 | Main comparison; TISR applied to the R2Gen baseline. Metric label follows the table’s B… | Textual Inversion and Self-supervised Refinement for Radiology Report GenerationSource quoteL109: +TISR(Ours) │ 0.358 │ 0.219 │ 0.147 │ 0.106 │ 0.139 │ 0.275 │ 0.467 │ 0.302 │ 0.367 |
| 2024 | R2GenCMN baseline | BLEU-1 | 0.344 | Main comparison; original baseline, compared with R2GenCMN + TISR. Metric label follows… | Textual Inversion and Self-supervised Refinement for Radiology Report GenerationSource quoteL111: R2GenCMN\textsuperscript{*}~\cite{ref-20} │ 0.344 │ 0.210 │ 0.139 │ 0.098 │ 0.136 │ 0.275 │ 0.455 │ 0.317 │ 0.374 |
| 2024 | R2GenCMN + TISR baseline | BLEU-1 | 0.363 | Main comparison; TISR applied to the R2GenCMN baseline. Metric label follows the table’… | Textual Inversion and Self-supervised Refinement for Radiology Report GenerationSource quoteL112: +TISR(Ours) │ 0.363 │ 0.224 │ 0.149 │ 0.105 │ 0.143 │ 0.279 │ 0.450 │ 0.344 │ 0.390 |
| 2024 | VLCI baseline | BLEU-1 | 0.393 | Main comparison; original baseline, compared with VLCI + TISR. Metric label follows the… | Textual Inversion and Self-supervised Refinement for Radiology Report GenerationSource quoteL114: VLCI\textsuperscript{*}~\cite{ref-18} │ 0.393 │ 0.239 │ 0.159 │ 0.113 │ 0.150 │ 0.276 │ 0.439 │ 0.283 │ 0.344 |
| 2024 | VLCI + TISR baseline | BLEU-1 | 0.396 | Main comparison; TISR applied to the VLCI baseline. Metric label follows the table’s BL… | Textual Inversion and Self-supervised Refinement for Radiology Report GenerationSource quoteL115: +TISR(Ours) │ 0.396 │ 0.242 │ 0.161 │ 0.115 │ 0.149 │ 0.278 │ 0.453 │ 0.306 │ 0.366 |
| 2024 | Standard beam search (InstructBLIP) baseline non-standard slice | BLEU | 12.76 | subset=ground-truth tags · backbone=InstructBLIP · decoding=standard beam search | A Data-Driven Guided Decoding Mechanism for Diagnostic CaptioningSource quoteL385: InstructBLIP │ 12.76 │ 13.39 │ 14.35 │ 16.27 │ 24.65 │ 25.61 |
| 2024 | Nguyen et al. clinical-document-guided model baseline | BLEU-4 (BL-4) | 0.224 | The review reports this as a highest NLP score; clinical documents, such as patient his… | Automatic Medical Report Generation: Methods and ApplicationsSource quoteL403: Human-computer interaction technology achieves the highest scores in both NLP and CE. Specifically, the inclusion of doctors' notes significantly enhances the quality of the generated reports. Nguyen et al. \cite{nguyen2021automated} achieved the best NLP scores on both MIMIC-CXR (BL-4: 0.224, MTR: 0.222, and RG-L: 0.390) and IU-Xray (BL-4: 0.235, MTR: 0.219, and RG-L: 0.436) by incorporating clinical documents. These clinical documents, which may include patients’ clinical histories or doctors’ notes, guide the model to focus on specific areas of the image and relevant diseases. For instance, if the doctor's note mentions ``shows cough and shortness of breath symptoms'', the model will focus on the lung area and consider pneumonia. In addition to human-computer interaction, the model involves disease classification, memory retrieval and traceback mechanism, as illustrated in Figure \ref{human}. Similarly, Liu et al. \cite{liu2023observation} introduced disease labels provided by radiologists, achieving the highest CE scores (P: 0.855, R: 0.730, and F: 0.773). Their model offers two options: automatic disease classification based on the input image or radiologist-provided potential disease labels. The latter results in markedly higher clinical efficacy in generated reports. Thus, incorporating human guidance into the model effectively improves the quality of the generated reports. |
| 2023 | XproNet + ITHN proposed | BLEU-4 (B-4) | 0.114 | Radiology report generation on the official MIMIC-CXR split. | Automatic Radiology Report Generation by Learning with Increasingly Hard NegativesSource quoteL180: XproNet + \textbf{\text{ITHN}} (ours) │ 0.370 │ \bf{0.230} │ 0.154 │ \bf{0.114} │ \bf{0.294} │ \bf{0.145} │ \bf{0.387} |
| 2023 | AdaMatch-Cyclic proposed | BLEU-1 (B-1) | 0.3793 | direction=CXR-to-report · training-setting=cyclic | Fine-Grained Image-Text Alignment in Medical Imaging Enables Explainable Cyclic Image-Report GenerationSource quoteL302: \checkmark │ \checkmark │ 0.3793 │ 0.2346 │ 0.1540 │ 0.1060 │ 0.1625 │ 0.2813 │ 1.0916 │ 3.3931 |
| 2023 | MedXChat proposed | BLEU-1 | 0.367 | CXR-to-Report NLP evaluation; BLEU-1 score. | Medxchat: A Unified Multimodal Large Language Model Framework Towards CXRS Understanding and GenerationSource quoteL209: MedXChat (Ours) │ 0.367 │ 0.235 │ 0.158 │ 0.111 │ 0.264 │ 0.135 │ 0.175 |
| 2023 | C^2M-DoT proposed | BLEU-1 | 0.4842 | split: test | C^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer networkSource quoteL275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850 |
| 2023 | KiUT proposed | BLEU-1 | 0.393 | split: test · input-images=single-image | KiUT: Knowledge-injected U-Transformer for Radiology Report GenerationSource quoteL229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321 |
| 2023 | Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposed | BLEU-3 (BL-3) | 0.162 | split: test | Enhanced Knowledge Injection for Radiology Report GenerationSource quoteL171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217 |
| 2023 | Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposed | BLEU-4 (BL-4) | 0.119 | split: test | Enhanced Knowledge Injection for Radiology Report GenerationSource quoteL171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217 |
| 2023 | MMTN proposed non-standard slice | BLEU-4 | 0.116 | subset=IU-CX criterion | MMTN: Multi-Modal Memory Transformer Network for Image-Report Consistent Medical Report GenerationSource quoteL472: 0.116 |
| 2023 | Clin-T5-Large + LoRA proposed | BLEU | 18.9 | peft · params=738M · backbone=Clin-T5-Large · adaptation=LoRA | RadAdapt: Radiology Report Summarization via Lightweight Domain Adaptation of Large Language ModelsSource quoteL175: LoRA │ large │ 18.9 │ 44.5 │ 90.0 │ 41.8 │ 70.9 |
| 2023 | REMOTE (100% labeled training data) proposed | BLEU-4 | 0.125 | split: test · labeled-training-data=100% | A Self-training Framework for Automated Medical Report GenerationSource quoteL322: The results in Table 1 show the comparison of REMOTE and existing strong methods, e.g., PPKED (Liu et al., 2021b), DeltaNet (Wu et al., 2022), and XProNet (Wang et al., 2022a). As we can see, when trained on 1% of labeled image-report pairs, combined with 90% of image-only data without reports, REMOTE demonstrates competitive performance with previous methods. When REMOTE is trained with the complete 100% labeled data, its performance surpasses the existing stateof-the-art methods on both two datasets. For example, on the MIMIC-CXR dataset, REMOTE achieves a BLEU-4 score of 0.125, a METEOR score of 0.157, a ROUGE-L score of 0.304, and a |
| 2023 | ORGan proposed | BLEU-4 (B-4) | 0.123 | split: test · beam-size=4 · max-decoding-length=104 | ORGAN: Observation-Guided Radiology Report Generation via Tree ReasoningSource quoteL241: \multirow{4}{*}{\textsc{\makecell{MIMIC\\-CXR}}} │ ORGan │ {0.407} │ {0.256} │ {0.172} │ {0.123} │ {0.162} │ {0.293} │ {0.416} │ {0.418} │ {0.385} |
| 2023 | R2GenGPT (Deep) proposed | BLEU-4 | 0.134 | split: test | R2GenGPT: Radiology Report Generation with frozen LLMsSource quoteL149: R2GenGPT (Deep) │ 0.411 │ 0.267 │ 0.186 │ 0.134 │ 0.297 │ 0.160 │ 0.269 |
| 2023 | PhenotypeCLIP proposed | BLEU-4 | 0.119 | split: test · beam-size=3 | Fine-grained Medical Vision-Language Representation Learning for Radiology Report GenerationSource quoteL238: BLEU-4 (0.119/0.205), METEOR (0.158/0.223), and ROUGE-L (0.286/0.414) scores, surpassing all other methods. In particular, our PhenotypeCLIP consistently outperformed all previous conventional contrastive learning methods across all evaluation metrics. For example, the PhenotypeCLIP outperforms previous contrastive learning models |
| 2023 | Swin-S+VLT (w/ pt) proposed | BLEU-4 | 0.099 | backbone=Swin-S · pretraining=with pretraining | Multi-modal Pre-training for Medical Vision-language Understanding and Generation: An Empirical Study with A New BenchmarkSource quoteL379: Swin-S+VLT (w/ pt) │ 0.340 │ 0.209 │ 0.139 │ 0.099 │ \bf0.166 │ \bf0.306 |
| 2023 | AdaMatch-Cyclic (CXR-to-report only) ablation | BLEU-1 (B-1) | 0.3542 | direction=CXR-to-report · training-setting=CXR-to-report only | Fine-Grained Image-Text Alignment in Medical Imaging Enables Explainable Cyclic Image-Report GenerationSource quoteL300: \checkmark │ 0.3542 │ 0.1973 │ 0.1190 │ 0.0758 │ 0.1329 │ 0.2392 |
| 2023 | PromptRRG (manual disease-enriched prompt, de1) ablation | BLEU-4 | 11.3 | prompt=manual disease-enriched (de1) · pseudo-labels=dataset-provided | Can Prompt Learning Benefit Radiology Report Generation?Source quoteL239: \multirow{2}{*} │ + de1 │ 34.8 │ 21.9 │ 15.3 │ 11.3 │ 14.5 │ 28.6 |
| 2023 | METransformer | BLEU-4 | 0.124 | MIMIC-CXR comparison table; result marked as quoted from the method's paper (dagger), r… | R2GenGPT: Radiology Report Generation with frozen LLMsSource quoteL146: METransformer^\dagger │ 0.386 │ 0.250 │ 0.169 │ 0.124 │ 0.291 │ 0.152 │ 0.362 |
| 2023 | XproNet baseline | BLEU-4 (B-4) | 0.105 | Radiology report generation on the official MIMIC-CXR split. | Automatic Radiology Report Generation by Learning with Increasingly Hard NegativesSource quoteL178: XproNet\cite{xpronet} │ 0.344 │ 0.215 │ 0.146 │ 0.105 │ 0.279 │ 0.138 │ 0.359 |
| 2023 | UniXGen-256 baseline | BLEU-1 | 0.365 | resolution=256 | Medxchat: A Unified Multimodal Large Language Model Framework Towards CXRS Understanding and GenerationSource quoteL207: UniXGen-256~\cite{lee2023unified} │ 0.365 │ 0.227 │ 0.147 │ 0.101 │ 0.294 │ 0.156 │ 0.138 |
| 2023 | MSAT baseline | BLEU-4 | 0.120 | report-section=findings | Normal-Abnormal Decoupling Memory for Medical Report GenerationSource quoteL309: 0.120 |
| 2023 | R2Gen baseline | BLEU-1 | 0.4700 | Main-results report-generation comparison; baselines were re-implemented. Averaging is … | C^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer networkSource quoteL274: R2Gen │ 0.4700 │ 0.3098 │ 0.2390 │ 0.1911 │ 0.1905 │ 0.3609 |
| 2023 | AlignTrans baseline | BLEU-1 | 0.378 | split: test · input-images=single-image | KiUT: Knowledge-injected U-Transformer for Radiology Report GenerationSource quoteL226: AlignTrans\cite{you2021aligntransformer} │ 0.378 │ 0.235 │ 0.156 │ 0.112 │ 0.158 │ 0.283 |
| 2023 | AlignTrans baseline non-standard slice | BLEU-4 | 0.112 | subset=IU-CX criterion | MMTN: Multi-Modal Memory Transformer Network for Image-Report Consistent Medical Report GenerationSource quoteL471: 0.112 |
| 2023 | Clin-T5-Large + prefix tuning baseline | BLEU | 16.1 | peft · params=738M · backbone=Clin-T5-Large · adaptation=prefix-tuning | RadAdapt: Radiology Report Summarization via Lightweight Domain Adaptation of Large Language ModelsSource quoteL174: \multirow{2}{*}{MIMIC-CXR} │ prefix tuning │ large │ 16.1 │ 43.4 │ 89.7 │ 41.0 │ 70.2 |
| 2023 | GPT-4V baseline | BLEU-1 | 0.338 | split: test · few-shot · prompt=few-shot mixed examples | A Comprehensive Study of GPT-4V's Multimodal Capabilities in Medical ImagingSource quoteL99: GPT-4V~\citep{OpenAI2023GPT4TR} │ 0.338 │ 0.190 │ 0.109 │ 0.061 │ 0.240 │ 0.125 │ 0.033 |
| 2023 | METransformer baseline | BLEU-1 | 0.386 | MIMIC-CXR comparison table; score reported for METransformer. | A Comprehensive Study of GPT-4V's Multimodal Capabilities in Medical ImagingSource quoteL98: METransformer~\citep{wang2023metransformer} │ 0.386 │ 0.250 │ 0.169 │ 0.124 │ 0.291 │ 0.152 │ 0.362 |
| 2022 | Ours (baseline+MSA+MCGN) proposed | BLEU-4 | 0.120 | split: test · fine-tuned · beam-size=3 · reinforcement-learning=no | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299 |
| 2022 | Ours+RL proposed | BLEU-4 | 0.136 | split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr reward | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429 |
| 2022 | SAT proposed | BLEU-1 | 0.634 | split: val · 5-fold-cross-validation | Medical image captioning via generative pretrained transformersSource quoteL210: \multicolumn{3}{c}{\bf SAT} │ 1.986 │ 0.478 │ 0.634 │ 0.549 │ 0.451 │ 0.383 |
| 2022 | Ours (MoCo pretraining + R2Gen) proposed | BLEU-1 (B-1) | 0.359 | split: test | Representative Image Feature Extraction via Contrastive Learning Pretraining for Chest X-ray Report GenerationSource quoteL253: Ours (MoCo pretraining + R2Gen) │ 0.359 │ 0.239 │ 0.167 │ 0.121 │ 0.304 |
| 2022 | BASE+CMM+RL (proposed full model; reported as OURS (CMM+RL)) proposed | BL-4 (BLEU-4) | 0.109 | split: test | Reinforced Cross-modal Alignment for Radiology Report GenerationSource quoteL560: 0.109 |
| 2022 | AlignTransformer proposed | BLEU-4 | 0.112 | split: test | AlignTransformer: Hierarchical Alignment of Visual Regions and Disease Tags for Medical Report GenerationSource quoteL178: AlignTransformer │ Ours │ \bf 0.378 │ \bf 0.235 │ \bf 0.156 │ \bf 0.112 │ \bf 0.158 │ 0.283 │ \bf 54 \multirow{7}{*}[-2pt]{IU-Xray} |
| 2022 | CAMANet proposed | BL-4 (BLEU-4) | 0.112 | Comparative results; official MIMIC-CXR split; one image view; beam size 3. | CAMANet: Class Activation Map Guided Attention Network for Radiology Report GenerationSource quoteL272: \multirow{5}{*} │ \bm{CAMANet} (Ours) │ 0.374 │ 0.230 │ 0.155 │ 0.112 │ 0.279 │ 0.145 │ 0.161 |
| 2022 | R2Gen (Res50) | BLEU-1 (B-1) | 0.354 | split: test · backbone=ResNet-50 | Representative Image Feature Extraction via Contrastive Learning Pretraining for Chest X-ray Report GenerationSource quoteL252: R2Gen (Res50) \cite{chen2020generating} │ 0.354 │ 0.236 │ 0.164 │ 0.118 │ 0.305 |
| 2022 | XPRONET | BLEU-1 (BL-1) | 0.344 | MIMIC-CXR comparison using the official data split; one image per patient was used. | Cross-Modal Prototype Driven Network for Radiology Report GenerationSource quoteL201: \multirow{5}{*} │ \bm{XPRONET} (Ours) │ 0.344 │ 0.215 │ 0.146 │ 0.105 │ 0.279 │ 0.138 |
| 2022 | R2GenCMN* | BLEU-1 (BL-1) | 0.354 | MIMIC-CXR comparison using the official data split; one image per patient was used. Ast… | Cross-Modal Prototype Driven Network for Radiology Report GenerationSource quoteL199: \multirow{5}{*} │ R2GenCMN (*)~\cite{chen2021cross} │ 0.354 │ 0.212 │ 0.139 │ 0.097 │ 0.271 │ 0.137 |
| 2022 | R2GenCMN | BL-4 (BLEU-4) | 0.106 | Comparative results; official MIMIC-CXR split; one image view; beam size 3. | CAMANet: Class Activation Map Guided Attention Network for Radiology Report GenerationSource quoteL269: \multirow{5}{*} │ R2GenCMN │ 0.353 │ 0.218 │ 0.148 │ 0.106 │ 0.278 │ 0.142 |
| 2022 | Co-Attention (re-implementation) baseline | B-4 (BLEU-4) | 0.095 | split: test · image-input=single | Competence-based Multimodal Curriculum Learning for Medical Report GenerationSource quoteL292: \multicolumn{1}{l|}{Co-Attention \cite{Jing2018Automatic}\ssymbol{2}} │ \multicolumn{1}{c|}{0.329} │ \multicolumn{1}{c|}{0.206} │ \multicolumn{1}{c|}{0.133} │ \multicolumn{1}{c|}{0.095} │ \multicolumn{1}{c|}{0.129} │ \multicolumn{1}{c|}{0.273} │ \multicolumn{1}{c|}{0.463} │ \multicolumn{1}{c|}{0.293} │ \multicolumn{1}{c|}{0.207} │ \multicolumn{1}{c|}{0.155} │ \multicolumn{1}{c|}{0.178} │ \multicolumn{1}{c }{0.365} |
| 2022 | R2GENCMN (Chen et al., 2021b) baseline | BL-4 (BLEU-4) | 0.106 | split: test · params=2021b | Reinforced Cross-modal Alignment for Radiology Report GenerationSource quoteL550: 0.106 |
| 2021 | RATCHET proposed non-standard slice | BLEU-1 | 0.232 | Average NLP metric score for predicted reports compared with ground-truth radiology rep… | RATCHET: Medical Transformer for Chest X-ray Diagnosis and ReportingSource quoteL130: Baseline │ TieNet │ ours BLEU-1 │ 0.208 │ 0.190 │ 0.232 |
| 2021 | RATCHET proposed non-standard slice | BLEU-4 | 0.057 | Average NLP metric score for predicted reports compared with ground-truth radiology rep… | RATCHET: Medical Transformer for Chest X-ray Diagnosis and ReportingSource quoteL133: BLEU-4 │ 0.052 │ 0.042 │ 0.057 |
| 2021 | KGAE (unsupervised; 0% paired data) proposed | BLEU-1 (B-1) | 0.221 | Natural-language generation results; trained unsupervised with 0% paired data. | Auto-Encoding Knowledge Graph for Unsupervised Medical Report GenerationSource quoteL252: R2Gen \cite{Chen2020Generating} │ 2020 │ 100% │ 0.470 │ 0.304 │ 0.219 │ 0.165 │ 0.187 │ 0.371 │ 0.353 │ 0.218 │ 0.145 │ 0.103 │ 0.142 │ 0.277 KGAE │ \multirow{3}{*}{Ours} │ \bf 0% │ 0.417 │ 0.263 │ 0.181 │ 0.126 │ 0.149 │ 0.318 │ 0.221 │ 0.144 │ 0.096 │ 0.062 │ 0.097 │ 0.208 |
| 2021 | Knowledge Matters (proposed knowledge-enhanced approach; Ours) proposed | BLEU-4 | 0.115 | split: test | Knowledge matters: Chest radiology report generation with general and specific knowledgeSource quoteL296: Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic} show the experimental results of the baselines model and our proposed model evaluated by natural language generation (NLG) metrics on both datasets, respectively. There are four observations. Firstly, our proposed model outperforms almost all other radiology report generation models. Compared to the state-of-the-art model, our model has a performance improvement , leading to an increase of BLEU-4 from 0.173 to 0.178 on the IU-Xray dataset and from 0.107 to 0.115 on the MIMIC-CXR dataset. It demonstrates the effectiveness of incorporating general and specific knowledge and the knowledge enhanced method. Secondly, compared with general image captioning methods (Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic}, row 1/2/3), the radiology report generation models (the rest of Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic}) achieve remarkable improvement. It indicates that it is crucial to propose domain-specific techniques for radiology report generation. Thirdly, our proposed method outperforms all the previous models on the IU-Xray dataset over all metrics, except that the ROUGE-L metric is slightly lower compared to M2TR~\citep{Nooralahzadeh2021Progressive}. The reason may be due to that the ROUGE-L focuses more on the recall of generated reports, and M2TR~\citep{Nooralahzadeh2021Progressive} proposes two-staged generation progress that first identifies accurate labels and later enriches those initial sequences to more fluent sentences. As a result, M2TR generates more description patterns in radiology reports, resulting a slightly higher ROUGE-L score. On the MIMIC-CXR dataset, our proposed method has higher performance than most of the previous methods. Although it is slightly lower than M2TR~\citep{Nooralahzadeh2021Progressive} and AlignTransformer~\citep{you2021aligntransformer} on the BLEU-1/2 scores, it achieves higher performances in terms of BLEU-3/4 scores. |
| 2021 | KGAE-Semi | BLEU-1 (B-1) | 0.352 | Natural-language generation results; trained with 60% paired data. | Auto-Encoding Knowledge Graph for Unsupervised Medical Report GenerationSource quoteL253: KGAE-Semi │ 60% │ 0.497 │ 0.320 │ 0.232 │ 0.171 │ 0.189 │ 0.379 │ 0.352 │ 0.219 │ 0.149 │ 0.108 │ 0.147 │ 0.290 |
| 2021 | KGAE-Supervised | BLEU-1 (B-1) | 0.369 | Natural-language generation results; trained with 100% paired data. | Auto-Encoding Knowledge Graph for Unsupervised Medical Report GenerationSource quoteL254: KGAE-Supervised │ 100% │ \bf 0.512 │ \bf 0.327 │ \bf 0.240 │ \bf 0.179 │ \bf 0.195 │ \bf 0.383 │ \bf 0.369 │ \bf 0.231 │ \bf 0.156 │ \bf 0.118 │ \bf 0.153 │ \bf 0.295 |