MIMIC-CXR

263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

68.772.676.580.32024M-FLAG: 69.5 (2023)DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained): 79.53 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 101 of 101 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026DRRG proposedBLEU-40.210denoising-steps=72 · sequence-length=100DRRG: A Discrete Diffusion Framework for Radiology Report Generation
Source quote
L355: NLG Metrics: The NLG results on MIMIC-CXR and CheXpert Plus are reported in Table~\ref{tab:mimic_nlg} and Table~\ref{tab:chex_plus}. On MIMIC-CXR, DRRG achieves the best performance on BLEU-2, BLEU-3, BLEU-4, and ROUGE-L, with scores of 0.332, 0.259, 0.210, and 0.343, respectively. It also obtains the second-best BLEU-1 score of 0.452, slightly behind REVTAF-RRG~\cite{zhou2025learnable}. Compared with recent LLM-based RRG methods, DRRG achieves stronger NLG performance with a substantially smaller 0.6B text decoder, whereas the listed LLM-based competitors use text decoders with 7B or more parameters. On CheXpert Plus, DRRG achieves the best BLEU-4 score and a competitive ROUGE-L of 0.265. These results demonstrate the effectiveness of DRRG, suggesting that DLLMs provide a strong alternative to conventional AR-based RRG models.
2026LePaX proposedBLEU-40.253Report-generation evaluation; the paper reports BLEU-4 / METEOR / ROUGE in that order.Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report Generation
Source quote
L341: On MIMIC-CXR, it achieves BLEU-4 / METEOR / ROUGE scores of 0.253 / 0.336 / 0.380, surpassing previous encoder–decoder, transformer, and LLM-based methods.
2026RIHA (Report-Image Hierarchical Alignment Transformer) proposedBLEU-10.385Reported benchmark result for RIHA on MIMIC-CXR; the split is not specified in the cite…RIHA: Report-Image Hierarchical Alignment for Radiology Report Generation
Source quote
L146: On the more challenging MIMIC-CXR dataset, RIHA demonstrates competitive results, achieving the best scores in BLEU-1 (0.385), BLEU-2 (0.251), METEOR (0.159), and ROUGE-L (0.293). Our method shows consistent improvements over recent approaches including M2KT~\cite{yang2023radiology} (4.6% improvement on BLEU-1), CAMANET~\cite{wang2024camanet} (4.9% improvement on BLEU-1), and COMG~\cite{gu2024complex} (11.6% improvement on BLEU-1).
2026BoxMed-RLBLEU-30.185Downstream chest X-ray report generation; report target is the findings section; MIMIC-…Reason like a radiologist: Chain-of-thought and reinforcement learning for verifiable report generation
Source quote
L798: BoxMed-RL demonstrates significant performance in NLG metrics, achieving state-of-the-art performance in BLEU-3 and BLEU-4 scores across two datasets: MIMIC-CXR (0.185 and 0.134, Table 1) and IU Xray (0.240 and 0.178, Table 2). It also yields an average improvement of 7 % in both METEOR and ROUGE-L, metrics that emphasize semantic adequacy and content coverage. These consistent gains on external datasets not included in pretraining underscore the robustness and generalizability of our framework.
2026BoxMed-RLBLEU-40.134Downstream chest X-ray report generation; report target is the findings section; MIMIC-…Reason like a radiologist: Chain-of-thought and reinforcement learning for verifiable report generation
Source quote
L798: BoxMed-RL demonstrates significant performance in NLG metrics, achieving state-of-the-art performance in BLEU-3 and BLEU-4 scores across two datasets: MIMIC-CXR (0.185 and 0.134, Table 1) and IU Xray (0.240 and 0.178, Table 2). It also yields an average improvement of 7 % in both METEOR and ROUGE-L, metrics that emphasize semantic adequacy and content coverage. These consistent gains on external datasets not included in pretraining underscore the robustness and generalizability of our framework.
2025GPT-4o, Thought Graph Traversal (TGT) proposedBLEU-49.84%split: test · backbone=GPT-4oSimple Radiology VLLM Test-time Scaling with Thought Graph Traversal
Source quote
L200: TGT │ 29.25 │ 15.81 │ 8.95 │ 9.84 │ 14.12 │ 26.50
2025HuatuoGPT-Vision, Thought Graph Traversal (TGT) proposedBLEU-411.34%split: test · backbone=HuatuoGPT-VisionSimple Radiology VLLM Test-time Scaling with Thought Graph Traversal
Source quote
L208: TGT │ 32.99 │ 18.89 │ 10.85 │ 11.34 │ 14.36 │ 27.06
2025MedUnifier (w TIG) proposedBLEU-1 (BL-1)41.5split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MedUnifier (w TIG) proposedBLEU-4 (BL-4)12.9split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025SS-ACL proposedBLEU-40.144split: test · test-samples=3858Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report Generation
Source quote
L447: {\color[HTML]{C00000} 0.144}
2025AM-MRG proposedBLEU-40.136NLG report-generation metric on MIMIC-CXR; split and averaging are not specified in the…Activating Associative Disease-Aware Vision Token Memory for LLM-Based X-Ray Report Generation
Source quote
L344: In the MIMIC-CXR dataset, AM-MRG secures the best results for all metrics except CIDEr, with scores of 0.426 for BLEU-1, 0.271 for BLEU-2, 0.187 for BLEU-3, 0.136 for BLEU-4, 0.291 for ROUGE-L, and 0.174 for METEOR. Additionally, BLEU-4 has improved by 8.8% relative to R2GenGPT~\cite{Wang2023R2GenGPT}.
2025CURV proposedBLEU-3 (B-3)9.85params=3BCURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report Generation
Source quote
L210: 9.85
2025OTDRG proposedBLEU-10.411Report-generation comparison table; table states results are from the original papers.Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMs
Source quote
L277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295
2025OTDRG proposedBLEU-40.128Report-generation comparison table; table states results are from the original papers.Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMs
Source quote
L277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295
2025RADAR proposedBLEU-10.509view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge Injection
Source quote
L224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports.
2025KIA proposedBLEU-40.138split: testKIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report Generation
Source quote
L535: Specifically, our KIA achieves 0.188 and 0.138
2025MediVLM proposedBLEU-40.059unsupervisedMediVLM: A Vision Language Model for Radiology Report Generation from Medical Images
Source quote
L486: 0.059
2025Gemini-2.5-pro (SOTA VLM thinking model) non-standard sliceBLEU-127.68Automated report generation on a representative 500-case subset; Original versus Vision…VisionCAD: An Integration-Free Radiology Copilot Framework
Source quote
L260: BLEU-1 │ 25.88 │ 25.17 │ 27.68 │ 27.84
2025Gemini-2.5-pro (SOTA VLM thinking model) non-standard sliceBLEU-127.84Automated report generation on a representative 500-case subset; Original versus Vision…VisionCAD: An Integration-Free Radiology Copilot Framework
Source quote
L260: BLEU-1 │ 25.88 │ 25.17 │ 27.68 │ 27.84
2025I3 + C2FD baselineBLEU-10.402Descriptive report-generation score on the official MIMIC-CXR split; no averaging proto…DART: Disease-aware Image-Text Alignment and Self-correcting Re-alignment for Trustworthy Radiology Report Generation
Source quote
L116: I3 + C2FD~\cite{liu2024bootstrapping} │ 0.402 │ 0.262 │ 0.180 │ 0.128 │ 0.291 │ 0.175
2025MAIRA-2 baselineBLEU-3 (B-3)9.01Radiology report generation; reported as the directly compared baseline for CURV.CURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report Generation
Source quote
L170: 9.01
2025BLIP-3 (longitudinal) baselineBleu-40.184split: test · input=current and prior findings · subset=2,461 frontal-view pairsA Review of Longitudinal Radiology Report Generation: Dataset Composition, Methods, and Performance Evaluation
Source quote
L596: Model performance was evaluated using the Bleu-4 and METEOR metrics. On 2,461 frontal-view pairs from the MIMIC-CXR test set, the longitudinal BLIP-3 achieved a Bleu-4 score of 0.184 and a METEOR score of 0.428, slightly outperforming the single-image BLIP-3 (0.088 and 0.306, respectively).
2025BLIP-3 (single-image) baselineBleu-40.088split: test · input=single image · subset=2,461 frontal-view pairsA Review of Longitudinal Radiology Report Generation: Dataset Composition, Methods, and Performance Evaluation
Source quote
L596: Model performance was evaluated using the Bleu-4 and METEOR metrics. On 2,461 frontal-view pairs from the MIMIC-CXR test set, the longitudinal BLIP-3 achieved a Bleu-4 score of 0.184 and a METEOR score of 0.428, slightly outperforming the single-image BLIP-3 (0.088 and 0.306, respectively).
2024FSE-1 proposedBL-1 (BLEU-1)0.397split: test · reference-report-truncation=M_gt=80Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report Generation
Source quote
L229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency.
2024EVOKE (multi-view; Stage 1 fact-serialization alignment with MPC, G, and L; Stage 2 indication and bridge enabled) proposedBLEU-4 (B-4)0.147resolution=224×224MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report Generation
Source quote
L180: EVOKE │ M │ F │ \ding{51} │ \ding{51} │ \ding{51} │ \ding{51} (\ding{51}) │ 0.262 │ 0.147 │ 0.167 │ 0.311 │ 0.276 │ 0.557 │ 0.499
2024WoLF proposedBLEU-10.496Report generation; official MIMIC-CXR split.WoLF: Wide-scope Large Language Model Framework for CXR Understanding
Source quote
L171: WoLF{} │ 0.496 │ 0.517 │ 0.335 │ 0.366 │ 0.233 │ 0.261 │ 0.165 │ 0.199 │ 0.187 │ 0.412 │ 0.370 │ 0.456
2024Libra proposedBLEU-151.3%Concurrent-work comparison; the compared models' inference sets differ, and some use su…Libra: Leveraging Temporal Images for Biomedical Radiology Analysis
Source quote
L570: BLEU-1 │ 39.2 │ -- │ 46.5 │ 33.9 │ 51.3 (10.3%)
2024Libra proposedBLEU-424.5%Concurrent-work comparison; the compared models' inference sets differ, and some use su…Libra: Leveraging Temporal Images for Biomedical Radiology Analysis
Source quote
L571: BLEU-4 │ 14.8 │ 17.8 │ 23.4 │ 10.3 │ 24.5 (4.7%)
2024FITA proposedBLEU-10.411split: testFITA: Fine-grained Image-Text Aligner for Radiology Report Generation
Source quote
L107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326
2024SGRRG proposedBLEU-10.434split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024SGRRG proposedBLEU-40.149split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024Ours (pathology-aware regional prompts; PARP) proposedBLEU-10.394Automated natural language generation metric; compared with state-of-the-art report-gen…Anatomy-Guided Radiology Report Generation with Pathology-Aware Regional Prompts
Source quote
L388: 0.394
2024R2GenCSR (Llama2 text decoder) proposedBLEU-40.136decoder=Llama2R2GenCSR: Retrieving Context Samples for Large Language Model based X-ray Medical Report Generation
Source quote
L345: As shown in Table~\ref{tab:results_iu_mimic}, we report our results on the large-scale MIMIC-CXR dataset. Our method achieved a BLEU-1 score of 0.420, a BLEU-4 score of 0.136, and a ROUGE-L score of 0.291, indicating its ability to generate precise and contextually relevant medical reports. The CIDEr score of 0.267 suggests that the method produces descriptive reports that closely match the reference summaries, highlighting its practical application in clinical settings. Note that our approach employs a dataset-specific strategy, utilizing Llama2 as the text decoder, which is the model variant optimized for the MIMIC-CXR dataset, ensuring that the model is well-suited to the medical reports it processes. Notably, as illustrated in Table~\ref{tab:Clinical_Efficacy_Metrics}, our method achieves competitive CE scores for the MIMIC-CXR dataset, highlighting the robustness of our model in handling imbalanced datasets by effectively capturing relationships in both major and minor categories.
2024MedCycle {CheXpert} proposedB-1 (BLEU-1)0.309MIMIC-CXR evaluation; images from CheXpert and reports from MIMIC-CXR for training; no …MedCycle: Unpaired Medical Report Generation via Cycle-Consistency
Source quote
L286: MedCycle {CheXpert} │ 0.309 │ 0.167 │ 0.098 │ 0.061 │ 0.115 │ 0.216 │ 0.461 │ 0.290 │ 0.201 │ 0.143 │ 0.182 │ 0.332 \\[0.01in]
2024MedCycle {PadChest} proposedB-1 (BLEU-1)0.349MIMIC-CXR evaluation; images from PadChest and reports from MIMIC-CXR for training. Pad…MedCycle: Unpaired Medical Report Generation via Cycle-Consistency
Source quote
L288: MedCycle {PadChest} │ 0.349 │ 0.195 │ 0.115 │ 0.072 │ 0.128 │ 0.239 │ 0.479 │ 0.291 │ 0.198 │ 0.140 │ 0.197 │ 0.360 \\[0.01in]
2024DMMCS (InstructBLIP) proposed non-standard sliceBLEU13.39subset=ground-truth tags · backbone=InstructBLIPA Data-Driven Guided Decoding Mechanism for Diagnostic Captioning
Source quote
L385: InstructBLIP │ 12.76 │ 13.39 │ 14.35 │ 16.27 │ 24.65 │ 25.61
2024Memory Alignment Network (MA; proposed model) proposedBLEU-10.396split: testAutomatic Radiology Reports Generation via Memory Alignment Network
Source quote
L254: 0.396
2024Ablation (a), direct Stage-2-only multi-view configuration (indication and bridge enabled) ablationBLEU-4 (B-4)0.134resolution=224×224MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report Generation
Source quote
L170: (a) │ M │ \ding{55} │ \ding{55} │ \ding{55} │ \ding{51} (\ding{51}) │ 0.247 │ 0.134 │ 0.158 │ 0.296 │ 0.252 │ 0.545 │ 0.480
2024KGAE {CheXpert}B-1 (BLEU-1)0.221MIMIC-CXR evaluation; images from CheXpert for training. The comparison setup is descri…MedCycle: Unpaired Medical Report Generation via Cycle-Consistency
Source quote
L285: KGAE {CheXpert} │ 0.221 │ 0.144 │ 0.096 │ 0.062 │ 0.097 │ 0.208 │ 0.417 │ 0.263 │ 0.181 │ 0.126 │ 0.149 │ 0.318
2024RadFoundBLEU-40.114Radiological report generation; reports include findings and impression sections and ar…Expert-level vision-language foundation model for real-world radiology and comprehensive evaluation
Source quote
L74: Radiological report benchmarks typically feature longer text lengths and contain more professional and detailed descriptions. Here, RadFound was evaluated for its synthesis skills in generating radiological text. On the IU-Xray dataset, RadFound achieved ROUGE-L and BLEU-4 scores of 0.357 and 0.186 respectively, while the baseline model achieved 0.294 and 0.125. On the MIMIC-CXR dataset, RadFound achieved ROUGE-L of 0.306 and BLEU-4 of 0.114, outperforming the baseline model, which obtained noticeably lower scores of 0.219 and 0.050, respectively (Fig. 3d). The excellent performance indicates that RadFound has developed proficient text generation capabilities, including the generation of longer and more complex radiological reports. Additionally, on the MIMIC-CXR dataset, we evaluated the clinical efficacy26, which measures the accuracy of descriptions for clinical abnormalities across diseases, such as pneumonia and edema (Supplementary Figure
2024GPT-4o, Prompt 1.1 Basic baselineBLEU-40.031prompt=basic direct generation · section=findingsGPT-4V Cannot Generate Radiology Reports Yet
Source quote
L701: 1.1 │ 0.331 │ 0.031 │ 0.225 │ 0.282 │ 0.134 │ 0.153 │ 0.163 │ 0.244 │ 0.418 │ 0.421
2024GPT-4-vision-preview (gt conditions) baselineBLEU-40.007section=impression · condition-input=ground-truth conditionsGPT-4V Cannot Generate Radiology Reports Yet
Source quote
L879: GPT-4V (gt) │ 0.176 │ 0.007 │ 0.185 │ 0.179 │ 0.885 │ \bf 0.977 │ 0.103 │ 0.584 │ \bf 0.958 │ \bf 0.431
2024Finetuned LLaMA-2 (gt conditions) baselineBLEU-40.094fine-tuned · params=7B · section=impression · backbone=LLaMA-2-7B · condition-input=ground-truth conditionsGPT-4V Cannot Generate Radiology Reports Yet
Source quote
L880: LLaMA-2 (gt) │ \bf 0.301 │ \bf 0.094 │ \bf 0.330 │ \bf 0.348 │ \bf 0.923 │ 0.957 │ \bf 0.286 │ \bf 0.703 │ 0.941 │ 0.710
2024+ DPO baselineBL-1 (BLEU)29.61split: test · backbone=LLaVA-Med v1.5MMedPO: Aligning Medical Vision-Language Models with Clinical-Aware Multimodal Preference Optimization
Source quote
L367: + DPO │ 41.63 │ 15.13 │ 5.56 │ 2.03 │ 12.95 │ 17.13 │ 29.61 │ 10.29 │ 3.61 │ 1.27 │ 9.45 │ 7.81
2024TransSQ baselineBLEU-10.423Report-generation comparison; table values quoted from published literature; WoLF evalu…WoLF: Wide-scope Large Language Model Framework for CXR Understanding
Source quote
L167: TransSQ~\cite{transsq} │ 0.423 │ 0.484 │ 0.261 │ 0.333 │ 0.171 │ 0.238 │ 0.116 │ 0.175 │ 0.168 │ 0.207 │ 0.286 │ 0.415
2024KiUT baselineBLEU-10.393split: testFITA: Fine-grained Image-Text Aligner for Radiology Report Generation
Source quote
L105: KiUT~\cite{huang2023kiut} │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321
2024CvT-212DistilGPT2 baselineBLEU-10.372MIMIC-CXR report generation; non-dagger comparison on the study's preprocessed dataset.HERGen: Elevating Radiology Report Generation with Longitudinal Data
Source quote
L285: CvT-212DistilGPT2~\cite{nicolson2023improving} │ 2022 │ 0.372 │ 0.231 │ 0.155 │ 0.111 │ 0.149 │ 0.280 │ 0.417 │ 0.295 │ 0.306
2024RECAP baselineBLEU-412.5%Report generation; MIMIC-CXR evaluation.Has multimodal learning delivered universal intelligence in healthcare? A comprehensive survey
Source quote
L833: However, these models are still constrained by the data bias inherent in current datasets, which impairs their ability to detect and accurately describe subtle anomalies. On the MIMIC-ABN dataset~\cite{ni-etal-2020-learning}, which exclusively contains anomaly descriptions from the MIMIC-CXR dataset, the performance of these models on various metrics is significantly degraded~\cite{ni-etal-2020-learning, DBLP:conf/emnlp/HouCXLL23}. For instance, the BLEU-4 and ROUGE scores of RECAP~\cite{DBLP:conf/emnlp/HouCXLL23} on MIMIC-CXR are 12.5% and 28.8%, respectively, while on MIMIC-ABN, they drop to 8% and 22.3%, respectively. Furthermore, these models often overlook individual variability and the influence of patient-specific clinical context on diagnostic conclusions. This lack of consideration for personalized clinical information limits the overall effectiveness and accuracy of the generated reports.
2024R2Gen baselineBLEU-10.350Main comparison; original baseline, compared with R2Gen + TISR. Metric label follows th…Textual Inversion and Self-supervised Refinement for Radiology Report Generation
Source quote
L108: R2Gen\textsuperscript{*}~\cite{ref-33} │ 0.350 │ 0.214 │ 0.143 │ 0.103 │ 0.135 │ 0.271 │ 0.424 │ 0.254 │ 0.317
2024R2Gen + TISR baselineBLEU-10.358Main comparison; TISR applied to the R2Gen baseline. Metric label follows the table’s B…Textual Inversion and Self-supervised Refinement for Radiology Report Generation
Source quote
L109: +TISR(Ours) │ 0.358 │ 0.219 │ 0.147 │ 0.106 │ 0.139 │ 0.275 │ 0.467 │ 0.302 │ 0.367
2024R2GenCMN baselineBLEU-10.344Main comparison; original baseline, compared with R2GenCMN + TISR. Metric label follows…Textual Inversion and Self-supervised Refinement for Radiology Report Generation
Source quote
L111: R2GenCMN\textsuperscript{*}~\cite{ref-20} │ 0.344 │ 0.210 │ 0.139 │ 0.098 │ 0.136 │ 0.275 │ 0.455 │ 0.317 │ 0.374
2024R2GenCMN + TISR baselineBLEU-10.363Main comparison; TISR applied to the R2GenCMN baseline. Metric label follows the table’…Textual Inversion and Self-supervised Refinement for Radiology Report Generation
Source quote
L112: +TISR(Ours) │ 0.363 │ 0.224 │ 0.149 │ 0.105 │ 0.143 │ 0.279 │ 0.450 │ 0.344 │ 0.390
2024VLCI baselineBLEU-10.393Main comparison; original baseline, compared with VLCI + TISR. Metric label follows the…Textual Inversion and Self-supervised Refinement for Radiology Report Generation
Source quote
L114: VLCI\textsuperscript{*}~\cite{ref-18} │ 0.393 │ 0.239 │ 0.159 │ 0.113 │ 0.150 │ 0.276 │ 0.439 │ 0.283 │ 0.344
2024VLCI + TISR baselineBLEU-10.396Main comparison; TISR applied to the VLCI baseline. Metric label follows the table’s BL…Textual Inversion and Self-supervised Refinement for Radiology Report Generation
Source quote
L115: +TISR(Ours) │ 0.396 │ 0.242 │ 0.161 │ 0.115 │ 0.149 │ 0.278 │ 0.453 │ 0.306 │ 0.366
2024Standard beam search (InstructBLIP) baseline non-standard sliceBLEU12.76subset=ground-truth tags · backbone=InstructBLIP · decoding=standard beam searchA Data-Driven Guided Decoding Mechanism for Diagnostic Captioning
Source quote
L385: InstructBLIP │ 12.76 │ 13.39 │ 14.35 │ 16.27 │ 24.65 │ 25.61
2024Nguyen et al. clinical-document-guided model baselineBLEU-4 (BL-4)0.224The review reports this as a highest NLP score; clinical documents, such as patient his…Automatic Medical Report Generation: Methods and Applications
Source quote
L403: Human-computer interaction technology achieves the highest scores in both NLP and CE. Specifically, the inclusion of doctors' notes significantly enhances the quality of the generated reports. Nguyen et al. \cite{nguyen2021automated} achieved the best NLP scores on both MIMIC-CXR (BL-4: 0.224, MTR: 0.222, and RG-L: 0.390) and IU-Xray (BL-4: 0.235, MTR: 0.219, and RG-L: 0.436) by incorporating clinical documents. These clinical documents, which may include patients’ clinical histories or doctors’ notes, guide the model to focus on specific areas of the image and relevant diseases. For instance, if the doctor's note mentions ``shows cough and shortness of breath symptoms'', the model will focus on the lung area and consider pneumonia. In addition to human-computer interaction, the model involves disease classification, memory retrieval and traceback mechanism, as illustrated in Figure \ref{human}. Similarly, Liu et al. \cite{liu2023observation} introduced disease labels provided by radiologists, achieving the highest CE scores (P: 0.855, R: 0.730, and F: 0.773). Their model offers two options: automatic disease classification based on the input image or radiologist-provided potential disease labels. The latter results in markedly higher clinical efficacy in generated reports. Thus, incorporating human guidance into the model effectively improves the quality of the generated reports.
2023XproNet + ITHN proposedBLEU-4 (B-4)0.114Radiology report generation on the official MIMIC-CXR split.Automatic Radiology Report Generation by Learning with Increasingly Hard Negatives
Source quote
L180: XproNet + \textbf{\text{ITHN}} (ours) │ 0.370 │ \bf{0.230} │ 0.154 │ \bf{0.114} │ \bf{0.294} │ \bf{0.145} │ \bf{0.387}
2023AdaMatch-Cyclic proposedBLEU-1 (B-1)0.3793direction=CXR-to-report · training-setting=cyclicFine-Grained Image-Text Alignment in Medical Imaging Enables Explainable Cyclic Image-Report Generation
Source quote
L302: \checkmark │ \checkmark │ 0.3793 │ 0.2346 │ 0.1540 │ 0.1060 │ 0.1625 │ 0.2813 │ 1.0916 │ 3.3931
2023MedXChat proposedBLEU-10.367CXR-to-Report NLP evaluation; BLEU-1 score.Medxchat: A Unified Multimodal Large Language Model Framework Towards CXRS Understanding and Generation
Source quote
L209: MedXChat (Ours) │ 0.367 │ 0.235 │ 0.158 │ 0.111 │ 0.264 │ 0.135 │ 0.175
2023C^2M-DoT proposedBLEU-10.4842split: testC^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer network
Source quote
L275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850
2023KiUT proposedBLEU-10.393split: test · input-images=single-imageKiUT: Knowledge-injected U-Transformer for Radiology Report Generation
Source quote
L229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321
2023Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposedBLEU-3 (BL-3)0.162split: testEnhanced Knowledge Injection for Radiology Report Generation
Source quote
L171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217
2023Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposedBLEU-4 (BL-4)0.119split: testEnhanced Knowledge Injection for Radiology Report Generation
Source quote
L171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217
2023MMTN proposed non-standard sliceBLEU-40.116subset=IU-CX criterionMMTN: Multi-Modal Memory Transformer Network for Image-Report Consistent Medical Report Generation
Source quote
L472: 0.116
2023Clin-T5-Large + LoRA proposedBLEU18.9peft · params=738M · backbone=Clin-T5-Large · adaptation=LoRARadAdapt: Radiology Report Summarization via Lightweight Domain Adaptation of Large Language Models
Source quote
L175: LoRA │ large │ 18.9 │ 44.5 │ 90.0 │ 41.8 │ 70.9
2023REMOTE (100% labeled training data) proposedBLEU-40.125split: test · labeled-training-data=100%A Self-training Framework for Automated Medical Report Generation
Source quote
L322: The results in Table 1 show the comparison of REMOTE and existing strong methods, e.g., PPKED (Liu et al., 2021b), DeltaNet (Wu et al., 2022), and XProNet (Wang et al., 2022a). As we can see, when trained on 1% of labeled image-report pairs, combined with 90% of image-only data without reports, REMOTE demonstrates competitive performance with previous methods. When REMOTE is trained with the complete 100% labeled data, its performance surpasses the existing stateof-the-art methods on both two datasets. For example, on the MIMIC-CXR dataset, REMOTE achieves a BLEU-4 score of 0.125, a METEOR score of 0.157, a ROUGE-L score of 0.304, and a
2023ORGan proposedBLEU-4 (B-4)0.123split: test · beam-size=4 · max-decoding-length=104ORGAN: Observation-Guided Radiology Report Generation via Tree Reasoning
Source quote
L241: \multirow{4}{*}{\textsc{\makecell{MIMIC\\-CXR}}} │ ORGan │ {0.407} │ {0.256} │ {0.172} │ {0.123} │ {0.162} │ {0.293} │ {0.416} │ {0.418} │ {0.385}
2023R2GenGPT (Deep) proposedBLEU-40.134split: testR2GenGPT: Radiology Report Generation with frozen LLMs
Source quote
L149: R2GenGPT (Deep) │ 0.411 │ 0.267 │ 0.186 │ 0.134 │ 0.297 │ 0.160 │ 0.269
2023PhenotypeCLIP proposedBLEU-40.119split: test · beam-size=3Fine-grained Medical Vision-Language Representation Learning for Radiology Report Generation
Source quote
L238: BLEU-4 (0.119/0.205), METEOR (0.158/0.223), and ROUGE-L (0.286/0.414) scores, surpassing all other methods. In particular, our PhenotypeCLIP consistently outperformed all previous conventional contrastive learning methods across all evaluation metrics. For example, the PhenotypeCLIP outperforms previous contrastive learning models
2023Swin-S+VLT (w/ pt) proposedBLEU-40.099backbone=Swin-S · pretraining=with pretrainingMulti-modal Pre-training for Medical Vision-language Understanding and Generation: An Empirical Study with A New Benchmark
Source quote
L379: Swin-S+VLT (w/ pt) │ 0.340 │ 0.209 │ 0.139 │ 0.099 │ \bf0.166 │ \bf0.306
2023AdaMatch-Cyclic (CXR-to-report only) ablationBLEU-1 (B-1)0.3542direction=CXR-to-report · training-setting=CXR-to-report onlyFine-Grained Image-Text Alignment in Medical Imaging Enables Explainable Cyclic Image-Report Generation
Source quote
L300: \checkmark │ 0.3542 │ 0.1973 │ 0.1190 │ 0.0758 │ 0.1329 │ 0.2392
2023PromptRRG (manual disease-enriched prompt, de1) ablationBLEU-411.3prompt=manual disease-enriched (de1) · pseudo-labels=dataset-providedCan Prompt Learning Benefit Radiology Report Generation?
Source quote
L239: \multirow{2}{*} │ + de1 │ 34.8 │ 21.9 │ 15.3 │ 11.3 │ 14.5 │ 28.6
2023METransformerBLEU-40.124MIMIC-CXR comparison table; result marked as quoted from the method's paper (dagger), r…R2GenGPT: Radiology Report Generation with frozen LLMs
Source quote
L146: METransformer^\dagger │ 0.386 │ 0.250 │ 0.169 │ 0.124 │ 0.291 │ 0.152 │ 0.362
2023XproNet baselineBLEU-4 (B-4)0.105Radiology report generation on the official MIMIC-CXR split.Automatic Radiology Report Generation by Learning with Increasingly Hard Negatives
Source quote
L178: XproNet\cite{xpronet} │ 0.344 │ 0.215 │ 0.146 │ 0.105 │ 0.279 │ 0.138 │ 0.359
2023UniXGen-256 baselineBLEU-10.365resolution=256Medxchat: A Unified Multimodal Large Language Model Framework Towards CXRS Understanding and Generation
Source quote
L207: UniXGen-256~\cite{lee2023unified} │ 0.365 │ 0.227 │ 0.147 │ 0.101 │ 0.294 │ 0.156 │ 0.138
2023MSAT baselineBLEU-40.120report-section=findingsNormal-Abnormal Decoupling Memory for Medical Report Generation
Source quote
L309: 0.120
2023R2Gen baselineBLEU-10.4700Main-results report-generation comparison; baselines were re-implemented. Averaging is …C^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer network
Source quote
L274: R2Gen │ 0.4700 │ 0.3098 │ 0.2390 │ 0.1911 │ 0.1905 │ 0.3609
2023AlignTrans baselineBLEU-10.378split: test · input-images=single-imageKiUT: Knowledge-injected U-Transformer for Radiology Report Generation
Source quote
L226: AlignTrans\cite{you2021aligntransformer} │ 0.378 │ 0.235 │ 0.156 │ 0.112 │ 0.158 │ 0.283
2023AlignTrans baseline non-standard sliceBLEU-40.112subset=IU-CX criterionMMTN: Multi-Modal Memory Transformer Network for Image-Report Consistent Medical Report Generation
Source quote
L471: 0.112
2023Clin-T5-Large + prefix tuning baselineBLEU16.1peft · params=738M · backbone=Clin-T5-Large · adaptation=prefix-tuningRadAdapt: Radiology Report Summarization via Lightweight Domain Adaptation of Large Language Models
Source quote
L174: \multirow{2}{*}{MIMIC-CXR} │ prefix tuning │ large │ 16.1 │ 43.4 │ 89.7 │ 41.0 │ 70.2
2023GPT-4V baselineBLEU-10.338split: test · few-shot · prompt=few-shot mixed examplesA Comprehensive Study of GPT-4V's Multimodal Capabilities in Medical Imaging
Source quote
L99: GPT-4V~\citep{OpenAI2023GPT4TR} │ 0.338 │ 0.190 │ 0.109 │ 0.061 │ 0.240 │ 0.125 │ 0.033
2023METransformer baselineBLEU-10.386MIMIC-CXR comparison table; score reported for METransformer.A Comprehensive Study of GPT-4V's Multimodal Capabilities in Medical Imaging
Source quote
L98: METransformer~\citep{wang2023metransformer} │ 0.386 │ 0.250 │ 0.169 │ 0.124 │ 0.291 │ 0.152 │ 0.362
2022Ours (baseline+MSA+MCGN) proposedBLEU-40.120split: test · fine-tuned · beam-size=3 · reinforcement-learning=noA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299
2022Ours+RL proposedBLEU-40.136split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr rewardA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429
2022SAT proposedBLEU-10.634split: val · 5-fold-cross-validationMedical image captioning via generative pretrained transformers
Source quote
L210: \multicolumn{3}{c}{\bf SAT} │ 1.986 │ 0.478 │ 0.634 │ 0.549 │ 0.451 │ 0.383
2022Ours (MoCo pretraining + R2Gen) proposedBLEU-1 (B-1)0.359split: testRepresentative Image Feature Extraction via Contrastive Learning Pretraining for Chest X-ray Report Generation
Source quote
L253: Ours (MoCo pretraining + R2Gen) │ 0.359 │ 0.239 │ 0.167 │ 0.121 │ 0.304
2022BASE+CMM+RL (proposed full model; reported as OURS (CMM+RL)) proposedBL-4 (BLEU-4)0.109split: testReinforced Cross-modal Alignment for Radiology Report Generation
Source quote
L560: 0.109
2022AlignTransformer proposedBLEU-40.112split: testAlignTransformer: Hierarchical Alignment of Visual Regions and Disease Tags for Medical Report Generation
Source quote
L178: AlignTransformer │ Ours │ \bf 0.378 │ \bf 0.235 │ \bf 0.156 │ \bf 0.112 │ \bf 0.158 │ 0.283 │ \bf 54 \multirow{7}{*}[-2pt]{IU-Xray}
2022CAMANet proposedBL-4 (BLEU-4)0.112Comparative results; official MIMIC-CXR split; one image view; beam size 3.CAMANet: Class Activation Map Guided Attention Network for Radiology Report Generation
Source quote
L272: \multirow{5}{*} │ \bm{CAMANet} (Ours) │ 0.374 │ 0.230 │ 0.155 │ 0.112 │ 0.279 │ 0.145 │ 0.161
2022R2Gen (Res50)BLEU-1 (B-1)0.354split: test · backbone=ResNet-50Representative Image Feature Extraction via Contrastive Learning Pretraining for Chest X-ray Report Generation
Source quote
L252: R2Gen (Res50) \cite{chen2020generating} │ 0.354 │ 0.236 │ 0.164 │ 0.118 │ 0.305
2022XPRONETBLEU-1 (BL-1)0.344MIMIC-CXR comparison using the official data split; one image per patient was used.Cross-Modal Prototype Driven Network for Radiology Report Generation
Source quote
L201: \multirow{5}{*} │ \bm{XPRONET} (Ours) │ 0.344 │ 0.215 │ 0.146 │ 0.105 │ 0.279 │ 0.138
2022R2GenCMN*BLEU-1 (BL-1)0.354MIMIC-CXR comparison using the official data split; one image per patient was used. Ast…Cross-Modal Prototype Driven Network for Radiology Report Generation
Source quote
L199: \multirow{5}{*} │ R2GenCMN (*)~\cite{chen2021cross} │ 0.354 │ 0.212 │ 0.139 │ 0.097 │ 0.271 │ 0.137
2022R2GenCMNBL-4 (BLEU-4)0.106Comparative results; official MIMIC-CXR split; one image view; beam size 3.CAMANet: Class Activation Map Guided Attention Network for Radiology Report Generation
Source quote
L269: \multirow{5}{*} │ R2GenCMN │ 0.353 │ 0.218 │ 0.148 │ 0.106 │ 0.278 │ 0.142
2022Co-Attention (re-implementation) baselineB-4 (BLEU-4)0.095split: test · image-input=singleCompetence-based Multimodal Curriculum Learning for Medical Report Generation
Source quote
L292: \multicolumn{1}{l|}{Co-Attention \cite{Jing2018Automatic}\ssymbol{2}} │ \multicolumn{1}{c|}{0.329} │ \multicolumn{1}{c|}{0.206} │ \multicolumn{1}{c|}{0.133} │ \multicolumn{1}{c|}{0.095} │ \multicolumn{1}{c|}{0.129} │ \multicolumn{1}{c|}{0.273} │ \multicolumn{1}{c|}{0.463} │ \multicolumn{1}{c|}{0.293} │ \multicolumn{1}{c|}{0.207} │ \multicolumn{1}{c|}{0.155} │ \multicolumn{1}{c|}{0.178} │ \multicolumn{1}{c }{0.365}
2022R2GENCMN (Chen et al., 2021b) baselineBL-4 (BLEU-4)0.106split: test · params=2021bReinforced Cross-modal Alignment for Radiology Report Generation
Source quote
L550: 0.106
2021RATCHET proposed non-standard sliceBLEU-10.232Average NLP metric score for predicted reports compared with ground-truth radiology rep…RATCHET: Medical Transformer for Chest X-ray Diagnosis and Reporting
Source quote
L130: Baseline │ TieNet │ ours BLEU-1 │ 0.208 │ 0.190 │ 0.232
2021RATCHET proposed non-standard sliceBLEU-40.057Average NLP metric score for predicted reports compared with ground-truth radiology rep…RATCHET: Medical Transformer for Chest X-ray Diagnosis and Reporting
Source quote
L133: BLEU-4 │ 0.052 │ 0.042 │ 0.057
2021KGAE (unsupervised; 0% paired data) proposedBLEU-1 (B-1)0.221Natural-language generation results; trained unsupervised with 0% paired data.Auto-Encoding Knowledge Graph for Unsupervised Medical Report Generation
Source quote
L252: R2Gen \cite{Chen2020Generating} │ 2020 │ 100% │ 0.470 │ 0.304 │ 0.219 │ 0.165 │ 0.187 │ 0.371 │ 0.353 │ 0.218 │ 0.145 │ 0.103 │ 0.142 │ 0.277 KGAE │ \multirow{3}{*}{Ours} │ \bf 0% │ 0.417 │ 0.263 │ 0.181 │ 0.126 │ 0.149 │ 0.318 │ 0.221 │ 0.144 │ 0.096 │ 0.062 │ 0.097 │ 0.208
2021Knowledge Matters (proposed knowledge-enhanced approach; Ours) proposedBLEU-40.115split: testKnowledge matters: Chest radiology report generation with general and specific knowledge
Source quote
L296: Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic} show the experimental results of the baselines model and our proposed model evaluated by natural language generation (NLG) metrics on both datasets, respectively. There are four observations. Firstly, our proposed model outperforms almost all other radiology report generation models. Compared to the state-of-the-art model, our model has a performance improvement , leading to an increase of BLEU-4 from 0.173 to 0.178 on the IU-Xray dataset and from 0.107 to 0.115 on the MIMIC-CXR dataset. It demonstrates the effectiveness of incorporating general and specific knowledge and the knowledge enhanced method. Secondly, compared with general image captioning methods (Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic}, row 1/2/3), the radiology report generation models (the rest of Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic}) achieve remarkable improvement. It indicates that it is crucial to propose domain-specific techniques for radiology report generation. Thirdly, our proposed method outperforms all the previous models on the IU-Xray dataset over all metrics, except that the ROUGE-L metric is slightly lower compared to M2TR~\citep{Nooralahzadeh2021Progressive}. The reason may be due to that the ROUGE-L focuses more on the recall of generated reports, and M2TR~\citep{Nooralahzadeh2021Progressive} proposes two-staged generation progress that first identifies accurate labels and later enriches those initial sequences to more fluent sentences. As a result, M2TR generates more description patterns in radiology reports, resulting a slightly higher ROUGE-L score. On the MIMIC-CXR dataset, our proposed method has higher performance than most of the previous methods. Although it is slightly lower than M2TR~\citep{Nooralahzadeh2021Progressive} and AlignTransformer~\citep{you2021aligntransformer} on the BLEU-1/2 scores, it achieves higher performances in terms of BLEU-3/4 scores.
2021KGAE-SemiBLEU-1 (B-1)0.352Natural-language generation results; trained with 60% paired data.Auto-Encoding Knowledge Graph for Unsupervised Medical Report Generation
Source quote
L253: KGAE-Semi │ 60% │ 0.497 │ 0.320 │ 0.232 │ 0.171 │ 0.189 │ 0.379 │ 0.352 │ 0.219 │ 0.149 │ 0.108 │ 0.147 │ 0.290
2021KGAE-SupervisedBLEU-1 (B-1)0.369Natural-language generation results; trained with 100% paired data.Auto-Encoding Knowledge Graph for Unsupervised Medical Report Generation
Source quote
L254: KGAE-Supervised │ 100% │ \bf 0.512 │ \bf 0.327 │ \bf 0.240 │ \bf 0.179 │ \bf 0.195 │ \bf 0.383 │ \bf 0.369 │ \bf 0.231 │ \bf 0.156 │ \bf 0.118 │ \bf 0.153 │ \bf 0.295