MIMIC-CXR

263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

68.772.676.580.32024M-FLAG: 69.5 (2023)DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained): 79.53 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 34 of 34 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025GPT-4o, Thought Graph Traversal (TGT) proposedBLEU-49.84%split: test · backbone=GPT-4oSimple Radiology VLLM Test-time Scaling with Thought Graph Traversal
Source quote
L200: TGT │ 29.25 │ 15.81 │ 8.95 │ 9.84 │ 14.12 │ 26.50
2025HuatuoGPT-Vision, Thought Graph Traversal (TGT) proposedBLEU-411.34%split: test · backbone=HuatuoGPT-VisionSimple Radiology VLLM Test-time Scaling with Thought Graph Traversal
Source quote
L208: TGT │ 32.99 │ 18.89 │ 10.85 │ 11.34 │ 14.36 │ 27.06
2025MedUnifier (w TIG) proposedBLEU-1 (BL-1)41.5split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025MedUnifier (w TIG) proposedBLEU-4 (BL-4)12.9split: test · vision-generation-task=enabledMedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations
Source quote
L254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0
2025SS-ACL proposedBLEU-40.144split: test · test-samples=3858Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report Generation
Source quote
L447: {\color[HTML]{C00000} 0.144}
2025KIA proposedBLEU-40.138split: testKIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report Generation
Source quote
L535: Specifically, our KIA achieves 0.188 and 0.138
2025BLIP-3 (longitudinal) baselineBleu-40.184split: test · input=current and prior findings · subset=2,461 frontal-view pairsA Review of Longitudinal Radiology Report Generation: Dataset Composition, Methods, and Performance Evaluation
Source quote
L596: Model performance was evaluated using the Bleu-4 and METEOR metrics. On 2,461 frontal-view pairs from the MIMIC-CXR test set, the longitudinal BLIP-3 achieved a Bleu-4 score of 0.184 and a METEOR score of 0.428, slightly outperforming the single-image BLIP-3 (0.088 and 0.306, respectively).
2025BLIP-3 (single-image) baselineBleu-40.088split: test · input=single image · subset=2,461 frontal-view pairsA Review of Longitudinal Radiology Report Generation: Dataset Composition, Methods, and Performance Evaluation
Source quote
L596: Model performance was evaluated using the Bleu-4 and METEOR metrics. On 2,461 frontal-view pairs from the MIMIC-CXR test set, the longitudinal BLIP-3 achieved a Bleu-4 score of 0.184 and a METEOR score of 0.428, slightly outperforming the single-image BLIP-3 (0.088 and 0.306, respectively).
2024FSE-1 proposedBL-1 (BLEU-1)0.397split: test · reference-report-truncation=M_gt=80Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report Generation
Source quote
L229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency.
2024FITA proposedBLEU-10.411split: testFITA: Fine-grained Image-Text Aligner for Radiology Report Generation
Source quote
L107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326
2024SGRRG proposedBLEU-10.434split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024SGRRG proposedBLEU-40.149split: test · subset=Chest ImaGenomeScene Graph Aided Radiology Report Generation
Source quote
L222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332
2024Memory Alignment Network (MA; proposed model) proposedBLEU-10.396split: testAutomatic Radiology Reports Generation via Memory Alignment Network
Source quote
L254: 0.396
2024+ DPO baselineBL-1 (BLEU)29.61split: test · backbone=LLaVA-Med v1.5MMedPO: Aligning Medical Vision-Language Models with Clinical-Aware Multimodal Preference Optimization
Source quote
L367: + DPO │ 41.63 │ 15.13 │ 5.56 │ 2.03 │ 12.95 │ 17.13 │ 29.61 │ 10.29 │ 3.61 │ 1.27 │ 9.45 │ 7.81
2024KiUT baselineBLEU-10.393split: testFITA: Fine-grained Image-Text Aligner for Radiology Report Generation
Source quote
L105: KiUT~\cite{huang2023kiut} │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321
2023C^2M-DoT proposedBLEU-10.4842split: testC^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer network
Source quote
L275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850
2023KiUT proposedBLEU-10.393split: test · input-images=single-imageKiUT: Knowledge-injected U-Transformer for Radiology Report Generation
Source quote
L229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321
2023Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposedBLEU-3 (BL-3)0.162split: testEnhanced Knowledge Injection for Radiology Report Generation
Source quote
L171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217
2023Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposedBLEU-4 (BL-4)0.119split: testEnhanced Knowledge Injection for Radiology Report Generation
Source quote
L171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217
2023REMOTE (100% labeled training data) proposedBLEU-40.125split: test · labeled-training-data=100%A Self-training Framework for Automated Medical Report Generation
Source quote
L322: The results in Table 1 show the comparison of REMOTE and existing strong methods, e.g., PPKED (Liu et al., 2021b), DeltaNet (Wu et al., 2022), and XProNet (Wang et al., 2022a). As we can see, when trained on 1% of labeled image-report pairs, combined with 90% of image-only data without reports, REMOTE demonstrates competitive performance with previous methods. When REMOTE is trained with the complete 100% labeled data, its performance surpasses the existing stateof-the-art methods on both two datasets. For example, on the MIMIC-CXR dataset, REMOTE achieves a BLEU-4 score of 0.125, a METEOR score of 0.157, a ROUGE-L score of 0.304, and a
2023ORGan proposedBLEU-4 (B-4)0.123split: test · beam-size=4 · max-decoding-length=104ORGAN: Observation-Guided Radiology Report Generation via Tree Reasoning
Source quote
L241: \multirow{4}{*}{\textsc{\makecell{MIMIC\\-CXR}}} │ ORGan │ {0.407} │ {0.256} │ {0.172} │ {0.123} │ {0.162} │ {0.293} │ {0.416} │ {0.418} │ {0.385}
2023R2GenGPT (Deep) proposedBLEU-40.134split: testR2GenGPT: Radiology Report Generation with frozen LLMs
Source quote
L149: R2GenGPT (Deep) │ 0.411 │ 0.267 │ 0.186 │ 0.134 │ 0.297 │ 0.160 │ 0.269
2023PhenotypeCLIP proposedBLEU-40.119split: test · beam-size=3Fine-grained Medical Vision-Language Representation Learning for Radiology Report Generation
Source quote
L238: BLEU-4 (0.119/0.205), METEOR (0.158/0.223), and ROUGE-L (0.286/0.414) scores, surpassing all other methods. In particular, our PhenotypeCLIP consistently outperformed all previous conventional contrastive learning methods across all evaluation metrics. For example, the PhenotypeCLIP outperforms previous contrastive learning models
2023AlignTrans baselineBLEU-10.378split: test · input-images=single-imageKiUT: Knowledge-injected U-Transformer for Radiology Report Generation
Source quote
L226: AlignTrans\cite{you2021aligntransformer} │ 0.378 │ 0.235 │ 0.156 │ 0.112 │ 0.158 │ 0.283
2023GPT-4V baselineBLEU-10.338split: test · few-shot · prompt=few-shot mixed examplesA Comprehensive Study of GPT-4V's Multimodal Capabilities in Medical Imaging
Source quote
L99: GPT-4V~\citep{OpenAI2023GPT4TR} │ 0.338 │ 0.190 │ 0.109 │ 0.061 │ 0.240 │ 0.125 │ 0.033
2022Ours (baseline+MSA+MCGN) proposedBLEU-40.120split: test · fine-tuned · beam-size=3 · reinforcement-learning=noA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299
2022Ours+RL proposedBLEU-40.136split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr rewardA Medical Semantic-Assisted Transformer for Radiographic Report Generation
Source quote
L96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429
2022Ours (MoCo pretraining + R2Gen) proposedBLEU-1 (B-1)0.359split: testRepresentative Image Feature Extraction via Contrastive Learning Pretraining for Chest X-ray Report Generation
Source quote
L253: Ours (MoCo pretraining + R2Gen) │ 0.359 │ 0.239 │ 0.167 │ 0.121 │ 0.304
2022BASE+CMM+RL (proposed full model; reported as OURS (CMM+RL)) proposedBL-4 (BLEU-4)0.109split: testReinforced Cross-modal Alignment for Radiology Report Generation
Source quote
L560: 0.109
2022AlignTransformer proposedBLEU-40.112split: testAlignTransformer: Hierarchical Alignment of Visual Regions and Disease Tags for Medical Report Generation
Source quote
L178: AlignTransformer │ Ours │ \bf 0.378 │ \bf 0.235 │ \bf 0.156 │ \bf 0.112 │ \bf 0.158 │ 0.283 │ \bf 54 \multirow{7}{*}[-2pt]{IU-Xray}
2022R2Gen (Res50)BLEU-1 (B-1)0.354split: test · backbone=ResNet-50Representative Image Feature Extraction via Contrastive Learning Pretraining for Chest X-ray Report Generation
Source quote
L252: R2Gen (Res50) \cite{chen2020generating} │ 0.354 │ 0.236 │ 0.164 │ 0.118 │ 0.305
2022Co-Attention (re-implementation) baselineB-4 (BLEU-4)0.095split: test · image-input=singleCompetence-based Multimodal Curriculum Learning for Medical Report Generation
Source quote
L292: \multicolumn{1}{l|}{Co-Attention \cite{Jing2018Automatic}\ssymbol{2}} │ \multicolumn{1}{c|}{0.329} │ \multicolumn{1}{c|}{0.206} │ \multicolumn{1}{c|}{0.133} │ \multicolumn{1}{c|}{0.095} │ \multicolumn{1}{c|}{0.129} │ \multicolumn{1}{c|}{0.273} │ \multicolumn{1}{c|}{0.463} │ \multicolumn{1}{c|}{0.293} │ \multicolumn{1}{c|}{0.207} │ \multicolumn{1}{c|}{0.155} │ \multicolumn{1}{c|}{0.178} │ \multicolumn{1}{c }{0.365}
2022R2GENCMN (Chen et al., 2021b) baselineBL-4 (BLEU-4)0.106split: test · params=2021bReinforced Cross-modal Alignment for Radiology Report Generation
Source quote
L550: 0.106
2021Knowledge Matters (proposed knowledge-enhanced approach; Ours) proposedBLEU-40.115split: testKnowledge matters: Chest radiology report generation with general and specific knowledge
Source quote
L296: Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic} show the experimental results of the baselines model and our proposed model evaluated by natural language generation (NLG) metrics on both datasets, respectively. There are four observations. Firstly, our proposed model outperforms almost all other radiology report generation models. Compared to the state-of-the-art model, our model has a performance improvement , leading to an increase of BLEU-4 from 0.173 to 0.178 on the IU-Xray dataset and from 0.107 to 0.115 on the MIMIC-CXR dataset. It demonstrates the effectiveness of incorporating general and specific knowledge and the knowledge enhanced method. Secondly, compared with general image captioning methods (Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic}, row 1/2/3), the radiology report generation models (the rest of Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic}) achieve remarkable improvement. It indicates that it is crucial to propose domain-specific techniques for radiology report generation. Thirdly, our proposed method outperforms all the previous models on the IU-Xray dataset over all metrics, except that the ROUGE-L metric is slightly lower compared to M2TR~\citep{Nooralahzadeh2021Progressive}. The reason may be due to that the ROUGE-L focuses more on the recall of generated reports, and M2TR~\citep{Nooralahzadeh2021Progressive} proposes two-staged generation progress that first identifies accurate labels and later enriches those initial sequences to more fluent sentences. As a result, M2TR generates more description patterns in radiology reports, resulting a slightly higher ROUGE-L score. On the MIMIC-CXR dataset, our proposed method has higher performance than most of the previous methods. Although it is slightly lower than M2TR~\citep{Nooralahzadeh2021Progressive} and AlignTransformer~\citep{you2021aligntransformer} on the BLEU-1/2 scores, it achieves higher performances in terms of BLEU-3/4 scores.