| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 34 of 34 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2025 | GPT-4o, Thought Graph Traversal (TGT) proposed | BLEU-4 | 9.84% | split: test · backbone=GPT-4o | Simple Radiology VLLM Test-time Scaling with Thought Graph TraversalSource quoteL200: TGT │ 29.25 │ 15.81 │ 8.95 │ 9.84 │ 14.12 │ 26.50 |
| 2025 | HuatuoGPT-Vision, Thought Graph Traversal (TGT) proposed | BLEU-4 | 11.34% | split: test · backbone=HuatuoGPT-Vision | Simple Radiology VLLM Test-time Scaling with Thought Graph TraversalSource quoteL208: TGT │ 32.99 │ 18.89 │ 10.85 │ 11.34 │ 14.36 │ 27.06 |
| 2025 | MedUnifier (w TIG) proposed | BLEU-1 (BL-1) | 41.5 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MedUnifier (w TIG) proposed | BLEU-4 (BL-4) | 12.9 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | SS-ACL proposed | BLEU-4 | 0.144 | split: test · test-samples=3858 | Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report GenerationSource quoteL447: {\color[HTML]{C00000} 0.144} |
| 2025 | KIA proposed | BLEU-4 | 0.138 | split: test | KIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report GenerationSource quoteL535: Specifically, our KIA achieves 0.188 and 0.138 |
| 2025 | BLIP-3 (longitudinal) baseline | Bleu-4 | 0.184 | split: test · input=current and prior findings · subset=2,461 frontal-view pairs | A Review of Longitudinal Radiology Report Generation: Dataset Composition, Methods, and Performance EvaluationSource quoteL596: Model performance was evaluated using the Bleu-4 and METEOR metrics. On 2,461 frontal-view pairs from the MIMIC-CXR test set, the longitudinal BLIP-3 achieved a Bleu-4 score of 0.184 and a METEOR score of 0.428, slightly outperforming the single-image BLIP-3 (0.088 and 0.306, respectively). |
| 2025 | BLIP-3 (single-image) baseline | Bleu-4 | 0.088 | split: test · input=single image · subset=2,461 frontal-view pairs | A Review of Longitudinal Radiology Report Generation: Dataset Composition, Methods, and Performance EvaluationSource quoteL596: Model performance was evaluated using the Bleu-4 and METEOR metrics. On 2,461 frontal-view pairs from the MIMIC-CXR test set, the longitudinal BLIP-3 achieved a Bleu-4 score of 0.184 and a METEOR score of 0.428, slightly outperforming the single-image BLIP-3 (0.088 and 0.306, respectively). |
| 2024 | FSE-1 proposed | BL-1 (BLEU-1) | 0.397 | split: test · reference-report-truncation=M_gt=80 | Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report GenerationSource quoteL229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency. |
| 2024 | FITA proposed | BLEU-1 | 0.411 | split: test | FITA: Fine-grained Image-Text Aligner for Radiology Report GenerationSource quoteL107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326 |
| 2024 | SGRRG proposed | BLEU-1 | 0.434 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | SGRRG proposed | BLEU-4 | 0.149 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | Memory Alignment Network (MA; proposed model) proposed | BLEU-1 | 0.396 | split: test | Automatic Radiology Reports Generation via Memory Alignment NetworkSource quoteL254: 0.396 |
| 2024 | + DPO baseline | BL-1 (BLEU) | 29.61 | split: test · backbone=LLaVA-Med v1.5 | MMedPO: Aligning Medical Vision-Language Models with Clinical-Aware Multimodal Preference OptimizationSource quoteL367: + DPO │ 41.63 │ 15.13 │ 5.56 │ 2.03 │ 12.95 │ 17.13 │ 29.61 │ 10.29 │ 3.61 │ 1.27 │ 9.45 │ 7.81 |
| 2024 | KiUT baseline | BLEU-1 | 0.393 | split: test | FITA: Fine-grained Image-Text Aligner for Radiology Report GenerationSource quoteL105: KiUT~\cite{huang2023kiut} │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321 |
| 2023 | C^2M-DoT proposed | BLEU-1 | 0.4842 | split: test | C^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer networkSource quoteL275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850 |
| 2023 | KiUT proposed | BLEU-1 | 0.393 | split: test · input-images=single-image | KiUT: Knowledge-injected U-Transformer for Radiology Report GenerationSource quoteL229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321 |
| 2023 | Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposed | BLEU-3 (BL-3) | 0.162 | split: test | Enhanced Knowledge Injection for Radiology Report GenerationSource quoteL171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217 |
| 2023 | Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposed | BLEU-4 (BL-4) | 0.119 | split: test | Enhanced Knowledge Injection for Radiology Report GenerationSource quoteL171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217 |
| 2023 | REMOTE (100% labeled training data) proposed | BLEU-4 | 0.125 | split: test · labeled-training-data=100% | A Self-training Framework for Automated Medical Report GenerationSource quoteL322: The results in Table 1 show the comparison of REMOTE and existing strong methods, e.g., PPKED (Liu et al., 2021b), DeltaNet (Wu et al., 2022), and XProNet (Wang et al., 2022a). As we can see, when trained on 1% of labeled image-report pairs, combined with 90% of image-only data without reports, REMOTE demonstrates competitive performance with previous methods. When REMOTE is trained with the complete 100% labeled data, its performance surpasses the existing stateof-the-art methods on both two datasets. For example, on the MIMIC-CXR dataset, REMOTE achieves a BLEU-4 score of 0.125, a METEOR score of 0.157, a ROUGE-L score of 0.304, and a |
| 2023 | ORGan proposed | BLEU-4 (B-4) | 0.123 | split: test · beam-size=4 · max-decoding-length=104 | ORGAN: Observation-Guided Radiology Report Generation via Tree ReasoningSource quoteL241: \multirow{4}{*}{\textsc{\makecell{MIMIC\\-CXR}}} │ ORGan │ {0.407} │ {0.256} │ {0.172} │ {0.123} │ {0.162} │ {0.293} │ {0.416} │ {0.418} │ {0.385} |
| 2023 | R2GenGPT (Deep) proposed | BLEU-4 | 0.134 | split: test | R2GenGPT: Radiology Report Generation with frozen LLMsSource quoteL149: R2GenGPT (Deep) │ 0.411 │ 0.267 │ 0.186 │ 0.134 │ 0.297 │ 0.160 │ 0.269 |
| 2023 | PhenotypeCLIP proposed | BLEU-4 | 0.119 | split: test · beam-size=3 | Fine-grained Medical Vision-Language Representation Learning for Radiology Report GenerationSource quoteL238: BLEU-4 (0.119/0.205), METEOR (0.158/0.223), and ROUGE-L (0.286/0.414) scores, surpassing all other methods. In particular, our PhenotypeCLIP consistently outperformed all previous conventional contrastive learning methods across all evaluation metrics. For example, the PhenotypeCLIP outperforms previous contrastive learning models |
| 2023 | AlignTrans baseline | BLEU-1 | 0.378 | split: test · input-images=single-image | KiUT: Knowledge-injected U-Transformer for Radiology Report GenerationSource quoteL226: AlignTrans\cite{you2021aligntransformer} │ 0.378 │ 0.235 │ 0.156 │ 0.112 │ 0.158 │ 0.283 |
| 2023 | GPT-4V baseline | BLEU-1 | 0.338 | split: test · few-shot · prompt=few-shot mixed examples | A Comprehensive Study of GPT-4V's Multimodal Capabilities in Medical ImagingSource quoteL99: GPT-4V~\citep{OpenAI2023GPT4TR} │ 0.338 │ 0.190 │ 0.109 │ 0.061 │ 0.240 │ 0.125 │ 0.033 |
| 2022 | Ours (baseline+MSA+MCGN) proposed | BLEU-4 | 0.120 | split: test · fine-tuned · beam-size=3 · reinforcement-learning=no | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299 |
| 2022 | Ours+RL proposed | BLEU-4 | 0.136 | split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr reward | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429 |
| 2022 | Ours (MoCo pretraining + R2Gen) proposed | BLEU-1 (B-1) | 0.359 | split: test | Representative Image Feature Extraction via Contrastive Learning Pretraining for Chest X-ray Report GenerationSource quoteL253: Ours (MoCo pretraining + R2Gen) │ 0.359 │ 0.239 │ 0.167 │ 0.121 │ 0.304 |
| 2022 | BASE+CMM+RL (proposed full model; reported as OURS (CMM+RL)) proposed | BL-4 (BLEU-4) | 0.109 | split: test | Reinforced Cross-modal Alignment for Radiology Report GenerationSource quoteL560: 0.109 |
| 2022 | AlignTransformer proposed | BLEU-4 | 0.112 | split: test | AlignTransformer: Hierarchical Alignment of Visual Regions and Disease Tags for Medical Report GenerationSource quoteL178: AlignTransformer │ Ours │ \bf 0.378 │ \bf 0.235 │ \bf 0.156 │ \bf 0.112 │ \bf 0.158 │ 0.283 │ \bf 54 \multirow{7}{*}[-2pt]{IU-Xray} |
| 2022 | R2Gen (Res50) | BLEU-1 (B-1) | 0.354 | split: test · backbone=ResNet-50 | Representative Image Feature Extraction via Contrastive Learning Pretraining for Chest X-ray Report GenerationSource quoteL252: R2Gen (Res50) \cite{chen2020generating} │ 0.354 │ 0.236 │ 0.164 │ 0.118 │ 0.305 |
| 2022 | Co-Attention (re-implementation) baseline | B-4 (BLEU-4) | 0.095 | split: test · image-input=single | Competence-based Multimodal Curriculum Learning for Medical Report GenerationSource quoteL292: \multicolumn{1}{l|}{Co-Attention \cite{Jing2018Automatic}\ssymbol{2}} │ \multicolumn{1}{c|}{0.329} │ \multicolumn{1}{c|}{0.206} │ \multicolumn{1}{c|}{0.133} │ \multicolumn{1}{c|}{0.095} │ \multicolumn{1}{c|}{0.129} │ \multicolumn{1}{c|}{0.273} │ \multicolumn{1}{c|}{0.463} │ \multicolumn{1}{c|}{0.293} │ \multicolumn{1}{c|}{0.207} │ \multicolumn{1}{c|}{0.155} │ \multicolumn{1}{c|}{0.178} │ \multicolumn{1}{c }{0.365} |
| 2022 | R2GENCMN (Chen et al., 2021b) baseline | BL-4 (BLEU-4) | 0.106 | split: test · params=2021b | Reinforced Cross-modal Alignment for Radiology Report GenerationSource quoteL550: 0.106 |
| 2021 | Knowledge Matters (proposed knowledge-enhanced approach; Ours) proposed | BLEU-4 | 0.115 | split: test | Knowledge matters: Chest radiology report generation with general and specific knowledgeSource quoteL296: Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic} show the experimental results of the baselines model and our proposed model evaluated by natural language generation (NLG) metrics on both datasets, respectively. There are four observations. Firstly, our proposed model outperforms almost all other radiology report generation models. Compared to the state-of-the-art model, our model has a performance improvement , leading to an increase of BLEU-4 from 0.173 to 0.178 on the IU-Xray dataset and from 0.107 to 0.115 on the MIMIC-CXR dataset. It demonstrates the effectiveness of incorporating general and specific knowledge and the knowledge enhanced method. Secondly, compared with general image captioning methods (Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic}, row 1/2/3), the radiology report generation models (the rest of Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic}) achieve remarkable improvement. It indicates that it is crucial to propose domain-specific techniques for radiology report generation. Thirdly, our proposed method outperforms all the previous models on the IU-Xray dataset over all metrics, except that the ROUGE-L metric is slightly lower compared to M2TR~\citep{Nooralahzadeh2021Progressive}. The reason may be due to that the ROUGE-L focuses more on the recall of generated reports, and M2TR~\citep{Nooralahzadeh2021Progressive} proposes two-staged generation progress that first identifies accurate labels and later enriches those initial sequences to more fluent sentences. As a result, M2TR generates more description patterns in radiology reports, resulting a slightly higher ROUGE-L score. On the MIMIC-CXR dataset, our proposed method has higher performance than most of the previous methods. Although it is slightly lower than M2TR~\citep{Nooralahzadeh2021Progressive} and AlignTransformer~\citep{you2021aligntransformer} on the BLEU-1/2 scores, it achieves higher performances in terms of BLEU-3/4 scores. |