| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 54 of 54 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | DRRG proposed | BLEU-4 | 0.210 | denoising-steps=72 · sequence-length=100 | DRRG: A Discrete Diffusion Framework for Radiology Report GenerationSource quoteL355: NLG Metrics: The NLG results on MIMIC-CXR and CheXpert Plus are reported in Table~\ref{tab:mimic_nlg} and Table~\ref{tab:chex_plus}. On MIMIC-CXR, DRRG achieves the best performance on BLEU-2, BLEU-3, BLEU-4, and ROUGE-L, with scores of 0.332, 0.259, 0.210, and 0.343, respectively. It also obtains the second-best BLEU-1 score of 0.452, slightly behind REVTAF-RRG~\cite{zhou2025learnable}. Compared with recent LLM-based RRG methods, DRRG achieves stronger NLG performance with a substantially smaller 0.6B text decoder, whereas the listed LLM-based competitors use text decoders with 7B or more parameters. On CheXpert Plus, DRRG achieves the best BLEU-4 score and a competitive ROUGE-L of 0.265. These results demonstrate the effectiveness of DRRG, suggesting that DLLMs provide a strong alternative to conventional AR-based RRG models. |
| 2026 | LePaX proposed | BLEU-4 | 0.253 | Report-generation evaluation; the paper reports BLEU-4 / METEOR / ROUGE in that order. | Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report GenerationSource quoteL341: On MIMIC-CXR, it achieves BLEU-4 / METEOR / ROUGE scores of 0.253 / 0.336 / 0.380, surpassing previous encoder–decoder, transformer, and LLM-based methods. |
| 2026 | RIHA (Report-Image Hierarchical Alignment Transformer) proposed | BLEU-1 | 0.385 | Reported benchmark result for RIHA on MIMIC-CXR; the split is not specified in the cite… | RIHA: Report-Image Hierarchical Alignment for Radiology Report GenerationSource quoteL146: On the more challenging MIMIC-CXR dataset, RIHA demonstrates competitive results, achieving the best scores in BLEU-1 (0.385), BLEU-2 (0.251), METEOR (0.159), and ROUGE-L (0.293). Our method shows consistent improvements over recent approaches including M2KT~\cite{yang2023radiology} (4.6% improvement on BLEU-1), CAMANET~\cite{wang2024camanet} (4.9% improvement on BLEU-1), and COMG~\cite{gu2024complex} (11.6% improvement on BLEU-1). |
| 2025 | GPT-4o, Thought Graph Traversal (TGT) proposed | BLEU-4 | 9.84% | split: test · backbone=GPT-4o | Simple Radiology VLLM Test-time Scaling with Thought Graph TraversalSource quoteL200: TGT │ 29.25 │ 15.81 │ 8.95 │ 9.84 │ 14.12 │ 26.50 |
| 2025 | HuatuoGPT-Vision, Thought Graph Traversal (TGT) proposed | BLEU-4 | 11.34% | split: test · backbone=HuatuoGPT-Vision | Simple Radiology VLLM Test-time Scaling with Thought Graph TraversalSource quoteL208: TGT │ 32.99 │ 18.89 │ 10.85 │ 11.34 │ 14.36 │ 27.06 |
| 2025 | MedUnifier (w TIG) proposed | BLEU-1 (BL-1) | 41.5 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | MedUnifier (w TIG) proposed | BLEU-4 (BL-4) | 12.9 | split: test · vision-generation-task=enabled | MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual RepresentationsSource quoteL254: MedUnifier (w TIG) │ 41.5 │ 26.3 │ 18.1 │ 12.9 │ 22.7 │ 34.0 |
| 2025 | SS-ACL proposed | BLEU-4 | 0.144 | split: test · test-samples=3858 | Self-Supervised Anatomical Consistency Learning for Vision-Grounded Medical Report GenerationSource quoteL447: {\color[HTML]{C00000} 0.144} |
| 2025 | AM-MRG proposed | BLEU-4 | 0.136 | NLG report-generation metric on MIMIC-CXR; split and averaging are not specified in the… | Activating Associative Disease-Aware Vision Token Memory for LLM-Based X-Ray Report GenerationSource quoteL344: In the MIMIC-CXR dataset, AM-MRG secures the best results for all metrics except CIDEr, with scores of 0.426 for BLEU-1, 0.271 for BLEU-2, 0.187 for BLEU-3, 0.136 for BLEU-4, 0.291 for ROUGE-L, and 0.174 for METEOR. Additionally, BLEU-4 has improved by 8.8% relative to R2GenGPT~\cite{Wang2023R2GenGPT}. |
| 2025 | CURV proposed | BLEU-3 (B-3) | 9.85 | params=3B | CURV: Coherent Uncertainty-Aware Reasoning in Vision-Language Models for X-Ray Report GenerationSource quoteL210: 9.85 |
| 2025 | OTDRG proposed | BLEU-1 | 0.411 | Report-generation comparison table; table states results are from the original papers. | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | OTDRG proposed | BLEU-4 | 0.128 | Report-generation comparison table; table states results are from the original papers. | Bridging Vision and Language: Optimal Transport-Driven Radiology Report Generation via LLMsSource quoteL277: Ours │ 0.474 │ 0.448 │ 0.436 │ 0.411 │ 0.128 │ 0.164 │ 0.295 |
| 2025 | RADAR proposed | BLEU-1 | 0.509 | view=frontal · backbone=BLIP-3 · beam-width=5 · resolution=384×384 | RADAR: Enhancing Radiology Report Generation with Supplementary Knowledge InjectionSource quoteL224: Comparison with MLLMs. As shown in Table \ref{table: mllm_mimic_frontal_results}, Radar achieves SOTA performance compared to other MLLM baselines. In terms of lexical metrics, Radar outperforms the best baselines (i.e., Libra and MAIRA-2) with absolute improvements of 1.7% in BLEU-4 and 1.3% in ROUGE-L, while maintaining competitive performance of 0.509 in BLEU-1 and 0.450 in METEOR. Regarding entity-level clinical metrics, our model achieves the best performance on RG-F_1 and RadCliQ_0, attaining scores of 0.346 and 2.61, respectively. Additionally, Radar surpasses the top baselines, achieving improvements across multiple observation-level clinical metrics, with (14)Macro-F_1 increasing to 0.460, (5)Macro-F_1 to 0.567, (14)Micro-F_1 to 0.627, and (5)Micro-F_1 to 0.653, respectively. Notably, the smallest gain over the second-best model is 2.1%, underscoring Radar's effectiveness. Furthermore, we provide an additional set of CheXpert results using the \textcolor{gray}{Uncertain as Positive} policy and compare Radar with MAIRA-1. We observe that the improvements under this setting follow a similar trend to those obtained with the Uncertain as Negative policy. These results collectively demonstrate the effectiveness of Radar in generating coherent and clinically accurate radiology reports. |
| 2025 | KIA proposed | BLEU-4 | 0.138 | split: test | KIA: Knowledge-Guided Implicit Vision-Language Alignment for Chest X-Ray Report GenerationSource quoteL535: Specifically, our KIA achieves 0.188 and 0.138 |
| 2025 | MediVLM proposed | BLEU-4 | 0.059 | unsupervised | MediVLM: A Vision Language Model for Radiology Report Generation from Medical ImagesSource quoteL486: 0.059 |
| 2024 | FSE-1 proposed | BL-1 (BLEU-1) | 0.397 | split: test · reference-report-truncation=M_gt=80 | Factual Serialization Enhancement: A Key Innovation for Chest X-ray Report GenerationSource quoteL229: As evident from Table \ref{table: main results}, FSE-1 demonstrates competitive performance compared to both retrieval-based and generative-based approaches, with generative-based methods generally outperforming retrieval-based ones. Specifically, FSE-1 achieves either the best or second-best performance in both NLG and CE metrics across specific scenarios (i.e., \({M-gt} \in \left\{ {60,80,90,100} \right\}\)) and general scenarios (i.e., \(M-gt=Cpl.\)). Notably, with \(M-gt=80\), FSE-1 reaches scores of 0.397 for BL-1, 0.238 for RG, and 0.470 for CX14. Although FSE-1 slightly trails behind CvTDistillGPT2 \cite{nicolson-improving} in some NLG metrics at \(M-gt=60\), it shows an overall performance improvement of 4.1%. As presented in Table \ref{table: main-results-iu}, our FSE-20 exhibits a slight advantage over peer methods, particularly excelling in the CX5 and CX14 metrics. Specifically, FSE-20 achieves scores of 0.504 for BL-1 and 0.607 for CX14, highlighting its effectiveness in clinical consistency. |
| 2024 | EVOKE (multi-view; Stage 1 fact-serialization alignment with MPC, G, and L; Stage 2 indication and bridge enabled) proposed | BLEU-4 (B-4) | 0.147 | resolution=224×224 | MCL: Multi-view Enhanced Contrastive Learning for Chest X-ray Report GenerationSource quoteL180: EVOKE │ M │ F │ \ding{51} │ \ding{51} │ \ding{51} │ \ding{51} (\ding{51}) │ 0.262 │ 0.147 │ 0.167 │ 0.311 │ 0.276 │ 0.557 │ 0.499 |
| 2024 | WoLF proposed | BLEU-1 | 0.496 | Report generation; official MIMIC-CXR split. | WoLF: Wide-scope Large Language Model Framework for CXR UnderstandingSource quoteL171: WoLF{} │ 0.496 │ 0.517 │ 0.335 │ 0.366 │ 0.233 │ 0.261 │ 0.165 │ 0.199 │ 0.187 │ 0.412 │ 0.370 │ 0.456 |
| 2024 | Libra proposed | BLEU-1 | 51.3% | Concurrent-work comparison; the compared models' inference sets differ, and some use su… | Libra: Leveraging Temporal Images for Biomedical Radiology AnalysisSource quoteL570: BLEU-1 │ 39.2 │ -- │ 46.5 │ 33.9 │ 51.3 (10.3%) |
| 2024 | Libra proposed | BLEU-4 | 24.5% | Concurrent-work comparison; the compared models' inference sets differ, and some use su… | Libra: Leveraging Temporal Images for Biomedical Radiology AnalysisSource quoteL571: BLEU-4 │ 14.8 │ 17.8 │ 23.4 │ 10.3 │ 24.5 (4.7%) |
| 2024 | FITA proposed | BLEU-1 | 0.411 | split: test | FITA: Fine-grained Image-Text Aligner for Radiology Report GenerationSource quoteL107: Ours (FITA) │ 0.411 │ 0.262 │ 0.173 │ 0.122 │ 0.172 │ 0.295 │ 0.365 │ 0.322 │ 0.326 |
| 2024 | SGRRG proposed | BLEU-1 | 0.434 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | SGRRG proposed | BLEU-4 | 0.149 | split: test · subset=Chest ImaGenome | Scene Graph Aided Radiology Report GenerationSource quoteL222: SGRRG │ 0.434 │ 0.285 │ 0.202 │ 0.149 │ 0.173 │ 0.326 │ 0.440 │ 0.323 │ 0.332 |
| 2024 | Ours (pathology-aware regional prompts; PARP) proposed | BLEU-1 | 0.394 | Automated natural language generation metric; compared with state-of-the-art report-gen… | Anatomy-Guided Radiology Report Generation with Pathology-Aware Regional PromptsSource quoteL388: 0.394 |
| 2024 | R2GenCSR (Llama2 text decoder) proposed | BLEU-4 | 0.136 | decoder=Llama2 | R2GenCSR: Retrieving Context Samples for Large Language Model based X-ray Medical Report GenerationSource quoteL345: As shown in Table~\ref{tab:results_iu_mimic}, we report our results on the large-scale MIMIC-CXR dataset. Our method achieved a BLEU-1 score of 0.420, a BLEU-4 score of 0.136, and a ROUGE-L score of 0.291, indicating its ability to generate precise and contextually relevant medical reports. The CIDEr score of 0.267 suggests that the method produces descriptive reports that closely match the reference summaries, highlighting its practical application in clinical settings. Note that our approach employs a dataset-specific strategy, utilizing Llama2 as the text decoder, which is the model variant optimized for the MIMIC-CXR dataset, ensuring that the model is well-suited to the medical reports it processes. Notably, as illustrated in Table~\ref{tab:Clinical_Efficacy_Metrics}, our method achieves competitive CE scores for the MIMIC-CXR dataset, highlighting the robustness of our model in handling imbalanced datasets by effectively capturing relationships in both major and minor categories. |
| 2024 | MedCycle {CheXpert} proposed | B-1 (BLEU-1) | 0.309 | MIMIC-CXR evaluation; images from CheXpert and reports from MIMIC-CXR for training; no … | MedCycle: Unpaired Medical Report Generation via Cycle-ConsistencySource quoteL286: MedCycle {CheXpert} │ 0.309 │ 0.167 │ 0.098 │ 0.061 │ 0.115 │ 0.216 │ 0.461 │ 0.290 │ 0.201 │ 0.143 │ 0.182 │ 0.332 \\[0.01in] |
| 2024 | MedCycle {PadChest} proposed | B-1 (BLEU-1) | 0.349 | MIMIC-CXR evaluation; images from PadChest and reports from MIMIC-CXR for training. Pad… | MedCycle: Unpaired Medical Report Generation via Cycle-ConsistencySource quoteL288: MedCycle {PadChest} │ 0.349 │ 0.195 │ 0.115 │ 0.072 │ 0.128 │ 0.239 │ 0.479 │ 0.291 │ 0.198 │ 0.140 │ 0.197 │ 0.360 \\[0.01in] |
| 2024 | DMMCS (InstructBLIP) proposed non-standard slice | BLEU | 13.39 | subset=ground-truth tags · backbone=InstructBLIP | A Data-Driven Guided Decoding Mechanism for Diagnostic CaptioningSource quoteL385: InstructBLIP │ 12.76 │ 13.39 │ 14.35 │ 16.27 │ 24.65 │ 25.61 |
| 2024 | Memory Alignment Network (MA; proposed model) proposed | BLEU-1 | 0.396 | split: test | Automatic Radiology Reports Generation via Memory Alignment NetworkSource quoteL254: 0.396 |
| 2023 | XproNet + ITHN proposed | BLEU-4 (B-4) | 0.114 | Radiology report generation on the official MIMIC-CXR split. | Automatic Radiology Report Generation by Learning with Increasingly Hard NegativesSource quoteL180: XproNet + \textbf{\text{ITHN}} (ours) │ 0.370 │ \bf{0.230} │ 0.154 │ \bf{0.114} │ \bf{0.294} │ \bf{0.145} │ \bf{0.387} |
| 2023 | AdaMatch-Cyclic proposed | BLEU-1 (B-1) | 0.3793 | direction=CXR-to-report · training-setting=cyclic | Fine-Grained Image-Text Alignment in Medical Imaging Enables Explainable Cyclic Image-Report GenerationSource quoteL302: \checkmark │ \checkmark │ 0.3793 │ 0.2346 │ 0.1540 │ 0.1060 │ 0.1625 │ 0.2813 │ 1.0916 │ 3.3931 |
| 2023 | MedXChat proposed | BLEU-1 | 0.367 | CXR-to-Report NLP evaluation; BLEU-1 score. | Medxchat: A Unified Multimodal Large Language Model Framework Towards CXRS Understanding and GenerationSource quoteL209: MedXChat (Ours) │ 0.367 │ 0.235 │ 0.158 │ 0.111 │ 0.264 │ 0.135 │ 0.175 |
| 2023 | C^2M-DoT proposed | BLEU-1 | 0.4842 | split: test | C^2M-DoT: Cross-modal consistent multi-view medical report generation with domain transfer networkSource quoteL275: C^2M-DoT(ours) │ 0.4842 │ 0.3450 │ 0.2579 │ 0.1925 │ 0.2098 │ 0.3850 |
| 2023 | KiUT proposed | BLEU-1 | 0.393 | split: test · input-images=single-image | KiUT: Knowledge-injected U-Transformer for Radiology Report GenerationSource quoteL229: Ours │ 0.393 │ 0.243 │ 0.159 │ 0.113 │ 0.160 │ 0.285 │ 0.371 │ 0.318 │ 0.321 |
| 2023 | Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposed | BLEU-3 (BL-3) | 0.162 | split: test | Enhanced Knowledge Injection for Radiology Report GenerationSource quoteL171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217 |
| 2023 | Enhanced Knowledge Injection framework (full model: WCK + MRK with MoK; table label “Ours”) proposed | BLEU-4 (BL-4) | 0.119 | split: test | Enhanced Knowledge Injection for Radiology Report GenerationSource quoteL171: Ours │ 0.360 │ 0.231 │ 0.162 │ 0.119 │ 0.298 │ 0.153 │ 0.217 |
| 2023 | MMTN proposed non-standard slice | BLEU-4 | 0.116 | subset=IU-CX criterion | MMTN: Multi-Modal Memory Transformer Network for Image-Report Consistent Medical Report GenerationSource quoteL472: 0.116 |
| 2023 | Clin-T5-Large + LoRA proposed | BLEU | 18.9 | peft · params=738M · backbone=Clin-T5-Large · adaptation=LoRA | RadAdapt: Radiology Report Summarization via Lightweight Domain Adaptation of Large Language ModelsSource quoteL175: LoRA │ large │ 18.9 │ 44.5 │ 90.0 │ 41.8 │ 70.9 |
| 2023 | REMOTE (100% labeled training data) proposed | BLEU-4 | 0.125 | split: test · labeled-training-data=100% | A Self-training Framework for Automated Medical Report GenerationSource quoteL322: The results in Table 1 show the comparison of REMOTE and existing strong methods, e.g., PPKED (Liu et al., 2021b), DeltaNet (Wu et al., 2022), and XProNet (Wang et al., 2022a). As we can see, when trained on 1% of labeled image-report pairs, combined with 90% of image-only data without reports, REMOTE demonstrates competitive performance with previous methods. When REMOTE is trained with the complete 100% labeled data, its performance surpasses the existing stateof-the-art methods on both two datasets. For example, on the MIMIC-CXR dataset, REMOTE achieves a BLEU-4 score of 0.125, a METEOR score of 0.157, a ROUGE-L score of 0.304, and a |
| 2023 | ORGan proposed | BLEU-4 (B-4) | 0.123 | split: test · beam-size=4 · max-decoding-length=104 | ORGAN: Observation-Guided Radiology Report Generation via Tree ReasoningSource quoteL241: \multirow{4}{*}{\textsc{\makecell{MIMIC\\-CXR}}} │ ORGan │ {0.407} │ {0.256} │ {0.172} │ {0.123} │ {0.162} │ {0.293} │ {0.416} │ {0.418} │ {0.385} |
| 2023 | R2GenGPT (Deep) proposed | BLEU-4 | 0.134 | split: test | R2GenGPT: Radiology Report Generation with frozen LLMsSource quoteL149: R2GenGPT (Deep) │ 0.411 │ 0.267 │ 0.186 │ 0.134 │ 0.297 │ 0.160 │ 0.269 |
| 2023 | PhenotypeCLIP proposed | BLEU-4 | 0.119 | split: test · beam-size=3 | Fine-grained Medical Vision-Language Representation Learning for Radiology Report GenerationSource quoteL238: BLEU-4 (0.119/0.205), METEOR (0.158/0.223), and ROUGE-L (0.286/0.414) scores, surpassing all other methods. In particular, our PhenotypeCLIP consistently outperformed all previous conventional contrastive learning methods across all evaluation metrics. For example, the PhenotypeCLIP outperforms previous contrastive learning models |
| 2023 | Swin-S+VLT (w/ pt) proposed | BLEU-4 | 0.099 | backbone=Swin-S · pretraining=with pretraining | Multi-modal Pre-training for Medical Vision-language Understanding and Generation: An Empirical Study with A New BenchmarkSource quoteL379: Swin-S+VLT (w/ pt) │ 0.340 │ 0.209 │ 0.139 │ 0.099 │ \bf0.166 │ \bf0.306 |
| 2022 | Ours (baseline+MSA+MCGN) proposed | BLEU-4 | 0.120 | split: test · fine-tuned · beam-size=3 · reinforcement-learning=no | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL95: Ours(baseline+MSA+MCGN) │ 0.373 │ 0.235 │ 0.162 │ 0.120 │ 0.282 │ 0.143 │ 0.299 |
| 2022 | Ours+RL proposed | BLEU-4 | 0.136 | split: test · fine-tuned · RL-epochs=20 · beam-size=3 · reinforcement-learning=CIDEr reward | A Medical Semantic-Assisted Transformer for Radiographic Report GenerationSource quoteL96: Ours+RL │ 0.413 │ 0.266 │ 0.186 │ 0.136 │ 0.298 │ 0.170 │ 0.429 |
| 2022 | SAT proposed | BLEU-1 | 0.634 | split: val · 5-fold-cross-validation | Medical image captioning via generative pretrained transformersSource quoteL210: \multicolumn{3}{c}{\bf SAT} │ 1.986 │ 0.478 │ 0.634 │ 0.549 │ 0.451 │ 0.383 |
| 2022 | Ours (MoCo pretraining + R2Gen) proposed | BLEU-1 (B-1) | 0.359 | split: test | Representative Image Feature Extraction via Contrastive Learning Pretraining for Chest X-ray Report GenerationSource quoteL253: Ours (MoCo pretraining + R2Gen) │ 0.359 │ 0.239 │ 0.167 │ 0.121 │ 0.304 |
| 2022 | BASE+CMM+RL (proposed full model; reported as OURS (CMM+RL)) proposed | BL-4 (BLEU-4) | 0.109 | split: test | Reinforced Cross-modal Alignment for Radiology Report GenerationSource quoteL560: 0.109 |
| 2022 | AlignTransformer proposed | BLEU-4 | 0.112 | split: test | AlignTransformer: Hierarchical Alignment of Visual Regions and Disease Tags for Medical Report GenerationSource quoteL178: AlignTransformer │ Ours │ \bf 0.378 │ \bf 0.235 │ \bf 0.156 │ \bf 0.112 │ \bf 0.158 │ 0.283 │ \bf 54 \multirow{7}{*}[-2pt]{IU-Xray} |
| 2022 | CAMANet proposed | BL-4 (BLEU-4) | 0.112 | Comparative results; official MIMIC-CXR split; one image view; beam size 3. | CAMANet: Class Activation Map Guided Attention Network for Radiology Report GenerationSource quoteL272: \multirow{5}{*} │ \bm{CAMANet} (Ours) │ 0.374 │ 0.230 │ 0.155 │ 0.112 │ 0.279 │ 0.145 │ 0.161 |
| 2021 | RATCHET proposed non-standard slice | BLEU-1 | 0.232 | Average NLP metric score for predicted reports compared with ground-truth radiology rep… | RATCHET: Medical Transformer for Chest X-ray Diagnosis and ReportingSource quoteL130: Baseline │ TieNet │ ours BLEU-1 │ 0.208 │ 0.190 │ 0.232 |
| 2021 | RATCHET proposed non-standard slice | BLEU-4 | 0.057 | Average NLP metric score for predicted reports compared with ground-truth radiology rep… | RATCHET: Medical Transformer for Chest X-ray Diagnosis and ReportingSource quoteL133: BLEU-4 │ 0.052 │ 0.042 │ 0.057 |
| 2021 | KGAE (unsupervised; 0% paired data) proposed | BLEU-1 (B-1) | 0.221 | Natural-language generation results; trained unsupervised with 0% paired data. | Auto-Encoding Knowledge Graph for Unsupervised Medical Report GenerationSource quoteL252: R2Gen \cite{Chen2020Generating} │ 2020 │ 100% │ 0.470 │ 0.304 │ 0.219 │ 0.165 │ 0.187 │ 0.371 │ 0.353 │ 0.218 │ 0.145 │ 0.103 │ 0.142 │ 0.277 KGAE │ \multirow{3}{*}{Ours} │ \bf 0% │ 0.417 │ 0.263 │ 0.181 │ 0.126 │ 0.149 │ 0.318 │ 0.221 │ 0.144 │ 0.096 │ 0.062 │ 0.097 │ 0.208 |
| 2021 | Knowledge Matters (proposed knowledge-enhanced approach; Ours) proposed | BLEU-4 | 0.115 | split: test | Knowledge matters: Chest radiology report generation with general and specific knowledgeSource quoteL296: Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic} show the experimental results of the baselines model and our proposed model evaluated by natural language generation (NLG) metrics on both datasets, respectively. There are four observations. Firstly, our proposed model outperforms almost all other radiology report generation models. Compared to the state-of-the-art model, our model has a performance improvement , leading to an increase of BLEU-4 from 0.173 to 0.178 on the IU-Xray dataset and from 0.107 to 0.115 on the MIMIC-CXR dataset. It demonstrates the effectiveness of incorporating general and specific knowledge and the knowledge enhanced method. Secondly, compared with general image captioning methods (Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic}, row 1/2/3), the radiology report generation models (the rest of Table~\ref{tab:NLG-iu} and ~\ref{tab:NLG-mimic}) achieve remarkable improvement. It indicates that it is crucial to propose domain-specific techniques for radiology report generation. Thirdly, our proposed method outperforms all the previous models on the IU-Xray dataset over all metrics, except that the ROUGE-L metric is slightly lower compared to M2TR~\citep{Nooralahzadeh2021Progressive}. The reason may be due to that the ROUGE-L focuses more on the recall of generated reports, and M2TR~\citep{Nooralahzadeh2021Progressive} proposes two-staged generation progress that first identifies accurate labels and later enriches those initial sequences to more fluent sentences. As a result, M2TR generates more description patterns in radiology reports, resulting a slightly higher ROUGE-L score. On the MIMIC-CXR dataset, our proposed method has higher performance than most of the previous methods. Although it is slightly lower than M2TR~\citep{Nooralahzadeh2021Progressive} and AlignTransformer~\citep{you2021aligntransformer} on the BLEU-1/2 scores, it achieves higher performances in terms of BLEU-3/4 scores. |