MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 21 of 21 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | FINO proposed | AUROC | 81.8 | split: test · params=2.7M label-supervised · subset=IID; 14 pathology labels · backbone=DINOv3 ViT-L/16 | Who Needs Labels? Adapting Vision Foundation Models With the Metadata You Already HaveSource quoteL201: \bf FINO (ours) │ 2.7M │ {\color{cyan}\Snow} │ {\bf 61.2} │ {\bf 53.1} │ \bf{52.9} │ {\bf 81.8} |
| 2026 | Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposed | AUROC | 97.43% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL226: S3: Case + Evidence + Claim │ 97.43 │ 87.78 │ 78.72 │ 92.03 │ 0.060 |
| 2026 | Case-grounded evidence verifier (S3: Case + Evidence + Claim; ModernBERT-large) proposed | AUROC | 55.62% | split: test | Case-Grounded Evidence Verification: A Framework for Constructing Evidence-Sensitive SupervisionSource quoteL1297: AUROC │ 97.43 ± 0.27 [97--98] │ 97.24 ± 0.33 [97--98] │ 55.62 ± 1.50 [53--59] |
| 2025 | Synthetic+Real mix model (maximal synthetic data) proposed | AUROC | 0.770 | split: test · training-data=66k real + up to 565k synthetic images · initialization=ImageNet-pretrained | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL135: The synthetic+real model with maximal data achieved an AUROC of 0.770 (CI: 0.762-0.778) for the multi-label classification task on the in-distribution MIMIC-CXR test set. |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.75 | split: test · fine-tuned · view=frontal · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL137: Frontal │ 0.75 │ 0.65 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.73 | split: test · fine-tuned · view=lateral · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL138: Lateral │ 0.73 │ 0.65 |
| 2025 | MVMAE proposed | macro-AUROC over 14 CheXpert labels | 0.75 | split: test · fine-tuned · view=frontal+lateral ensemble · fusion=late · labels=5,000 | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL139: Ensemble │ 0.75 │ 0.69 \multirow{3}{*}{Contrastive} |
| 2025 | Real-only baseline baseline | AUROC | 0.772 | split: test · training-data=66k real images · initialization=ImageNet-pretrained | Improving Performance, Robustness, and Fairness of Radiographic AI Models with Finely-Controllable Synthetic DataSource quoteL136: This was on par with the real-only baseline which had an AUROC of 0.772 (CI: 0.765-0.781), and the difference between the two was not statistically significant (p-value=0.67). |
| 2025 | Supervised baseline (trained from scratch) baseline | macro-AUROC over 14 CheXpert labels | 0.69 | split: test · fine-tuned · view=frontal · labels=5,000 · training=from scratch | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL134: Frontal │ 0.69 |
| 2025 | Supervised baseline (trained from scratch) baseline | macro-AUROC over 14 CheXpert labels | 0.70 | split: test · fine-tuned · view=lateral · labels=5,000 · training=from scratch | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL135: Lateral │ 0.70 |
| 2025 | Supervised baseline (trained from scratch) baseline | macro-AUROC over 14 CheXpert labels | 0.70 | split: test · fine-tuned · view=frontal+lateral ensemble · fusion=late · labels=5,000 · training=from scratch | Leveraging the Structure of Medical Data for Improved Representation LearningSource quoteL136: Ensemble │ 0.70 │ - \multirow{3}{*}{MVMAE} |
| 2024 | MMVM VAE (lateral representation zL) proposed | AUROC | 78.7% | split: test · evaluation=binary random forest · representation=lateral unimodal latent zL | Unity by Diversity: Improved Representation Learning for Multimodal VAEsSource quoteL294: PoE VAE’s frontal representations zF (MMVM zL: 78.7%, PoE zF : 78.5%), even though the lateral modality seems generally less informative (supervised xL: 79.0%, xF : 81.7%) for this task. The same observation can be made for other labels (see detailed results and discussion in Appendix B.7.3). |
| 2024 | MSN + x_sex or MSN + x_D (both reported at this score) | AUROC | 0.751 | split: test · linear-probe · backbone=ViT-S | Multi-modal Masked Siamese Network Improves Chest X-Ray Representation LearningSource quoteL185: First, we note that all of the models that incorporate EHR during pretraining achieve a better performance compared to the best performing baseline, vanilla MSN. The improvement is at least 1% in terms of AUROC and AUPRC, with a maximum improvement of 2% when incorporating demographic information, 0.751 AUROC with x-sex or x-D, compared to 0.731 AUROC with MSN. Additionally, in most experiments where we pretrain with a single EHR feature achieve improvements greater than 1.5%, while pretraining with groups of features yields slightly lower performance improvements. |
| 2024 | PoE VAE (frontal representation zF) baseline | AUROC | 78.5% | split: test · evaluation=binary random forest · representation=frontal unimodal latent zF | Unity by Diversity: Improved Representation Learning for Multimodal VAEsSource quoteL294: PoE VAE’s frontal representations zF (MMVM zL: 78.7%, PoE zF : 78.5%), even though the lateral modality seems generally less informative (supervised xL: 79.0%, xF : 81.7%) for this task. The same observation can be made for other labels (see detailed results and discussion in Appendix B.7.3). |
| 2024 | MSN baseline | AUROC | 0.731 | split: test · linear-probe · backbone=ViT-S | Multi-modal Masked Siamese Network Improves Chest X-Ray Representation LearningSource quoteL155: MSN │ 0.731 (0.727, 0.734) │ 0.291 (0.289, 0.294) |
| 2023 | BiomedJourney proposed | Mean AUROC (pathology classifier) | 80.54 | split: test | BiomedJourney: Counterfactual Biomedical Image Generation by Instruction-Learning from Multimodal Patient JourneysSource quoteL273: BiomedJourney\xspace{} (Ours) │ 72.08 │ 73.76 │ 88.64 │ 88.11 │ 80.12 │ 80.54 │ {10.9} |
| 2023 | RoentGen (table label: Roentgen) baseline | Mean AUROC (pathology classifier) | 79.61 | split: test | BiomedJourney: Counterfactual Biomedical Image Generation by Instruction-Learning from Multimodal Patient JourneysSource quoteL272: Roentgen~\citep{chambon2022roentgen} │ 70.05 │ 77.85 │ 78.66 │ 86.20 │ 85.26 │ 79.61 │ {40.74} |
| 2023 | InstructPix2Pix (IP2P) baseline | Mean AUROC (pathology classifier) | 58.10 | split: test | BiomedJourney: Counterfactual Biomedical Image Generation by Instruction-Learning from Multimodal Patient JourneysSource quoteL271: IP2P~\citep{brooks2023instructpix2pix} │ 57.38 │ 53.70 │ 62.59 │ 58.85 │ 57.97 │ 58.10 │ {60.15} |
| 2022 | DenseNet-121 trained from scratch on 1.1k real + 1.1k synthetic images proposed | AUROC | 0.77 | split: test · findings=6 · classifier=DenseNet-121 · training-data=1.1k real + 1.1k synthetic | RoentGen: Vision-Language Foundation Model for Chest X-ray GenerationSource quoteL378: ~~ 1.1k R/S │ 1.1k │ 1.1k │ 0.77 (\uparrow0.04) │ 0.76 |
| 2022 | DenseNet-121 trained from scratch on 5.5k synthetic images proposed | AUROC | 0.75 | split: test · findings=6 · classifier=DenseNet-121 · training-data=5.5k synthetic | RoentGen: Vision-Language Foundation Model for Chest X-ray GenerationSource quoteL379: ~~ 5.5k S │ 5.5k │ 0.75 (\uparrow0.02) │ 0.78 |
| 2022 | Raw data (plaintext baseline) baseline | ROC AUC | 0.86 | split: test · input=raw data · tasks=four chest X-ray diagnoses | Syfer: Neural Obfuscation for Private Data ReleaseSource quoteL382: Using raw data │ 0.91 │ 0.78 │ 0.89 │ 0.85 │ 0.86 |