MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 41 of 41 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | RadFusion (GPT-5 rewriter, default instruction) proposed | AUC-ROC (macro average) | .90 | rewriter=GPT-5 · instruction=default | RadFusion: Towards Threshold-Controllable Radiology Report GenerationSource quoteL194: GPT-5 │ default │ .93 │ .92 │ .92 │ .84 │ .92 │ .91 │ .88 │ .90 │ .88 │ .90 │ .90 │ .89 │ .93 │ .90 |
| 2025 | MedOrch proposed | Macro AUC | 61.2% | Chest X-ray analysis; macro-level metric. | MedOrch: Medical Diagnosis with Tool-Augmented Reasoning Agents for Flexible ExtensibilitySource quoteL4: Healthcare decision-making represents one of the most challenging domains for Artificial Intelligence (AI), requiring the integration of diverse knowledge sources, complex reasoning, and various external analytical tools. Current AI systems often rely on either task-specific models, which offer limited adaptability, or general language models without grounding with specialized external knowledge and tools. We introduce \texttt{MedOrch}\xspace, a novel framework that orchestrates multiple specialized tools and reasoning agents to provide comprehensive medical decision support. \texttt{MedOrch}\xspace employs a modular, agent-based architecture that facilitates the flexible integration of domain-specific tools without altering the core system. Furthermore, it ensures transparent and traceable reasoning processes, enabling clinicians to meticulously verify each intermediate step underlying the system’s recommendations. We evaluate \texttt{MedOrch}\xspace across three distinct medical applications: Alzheimer's disease diagnosis, chest X-ray interpretation, and medical visual question answering, using authentic clinical datasets. The results demonstrate \texttt{MedOrch}\xspace's competitive performance across these diverse medical tasks. Notably, in Alzheimer's disease diagnosis, \texttt{MedOrch}\xspace achieves an accuracy of 93.26%, surpassing the state-of-the-art baseline by over four percentage points. For predicting Alzheimer's disease progression, it attains a 50.35% accuracy, marking a significant improvement. In chest X-ray analysis, \texttt{MedOrch}\xspace exhibits superior performance with a Macro AUC of 61.2% and a Macro F1-score of 25.5%. Moreover, in complex multimodal visual question answering (Image+Table), \texttt{MedOrch}\xspace achieves an accuracy of 54.47%. These findings underscore \texttt{MedOrch}\xspace's potential to advance healthcare AI by enabling reasoning-driven tool utilization for multimodal medical data processing and supporting intricate cognitive tasks in clinical decision-making. |
| 2025 | R-CLIP-opt proposed | AUC | 0.848 | subset=1% · backbone=CLIP | CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest RadiographsSource quoteL198: R-CLIP-opt (ours) │ Generated report │ 1% │ 0.848 │ 0.780 |
| 2025 | XMedGPT sentence-level uncertainty estimation proposed non-standard slice | AUC | 0.764 | split: test · method=semantic entropy with test-time scaling · subset=200 samples | Multi-Modal Explainable Medical AI Assistant for Trustworthy Human-AI CollaborationSource quoteL76: Having validated the effectiveness of our uncertainty estimation approach on medical VQA tasks, we extended it to the domain of medical report captioning for sentence-level uncertainty estimation, as illustrated in \Cref{fig:Uncertainty_method}. For each sentence generated in a medical report, our system generates multiple questions based on the sentence using a large language model. The consistency between the answers to these questions and the caption is assessed, with semantic entropy calculated to quantify uncertainty for each sentence. We evaluated the reliability of the uncertainty estimates on a subset (n = 200) of the MIMIC-CXR test dataset. As the number of questions increased from 1 to 5, the AUC improved from 0.676 to 0.764, reflecting a 13.02% enhancement. This substantial improvement demonstrates the effectiveness of combining semantic entropy with test-time scaling for estimating sentence-level uncertainty. |
| 2025 | Ark (+) | average AUC | 0.788 | split: test | VisionCAD: An Integration-Free Radiology Copilot FrameworkSource quoteL241: To assess performance in complex clinical scenarios, we evaluated the MIMIC-CXR dataset for multi-label chest pathology detection. Figure~\ref{fig:exp2}(a) presents the detailed AUC scores across 14 conditions for three image types, with statistical confidence intervals derived from 1000 bootstrap samples. The results show that our Quality Enhancer module substantially improves diagnostic utility: the average AUC score improves from 0.728 for raw captured images to 0.788 for VisionCAD-processed images, nearly matching the 0.799 AUC achieved on original images. |
| 2025 | Ark (+) | average AUC | 0.799 | split: test | VisionCAD: An Integration-Free Radiology Copilot FrameworkSource quoteL241: To assess performance in complex clinical scenarios, we evaluated the MIMIC-CXR dataset for multi-label chest pathology detection. Figure~\ref{fig:exp2}(a) presents the detailed AUC scores across 14 conditions for three image types, with statistical confidence intervals derived from 1000 bootstrap samples. The results show that our Quality Enhancer module substantially improves diagnostic utility: the average AUC score improves from 0.728 for raw captured images to 0.788 for VisionCAD-processed images, nearly matching the 0.799 AUC achieved on original images. |
| 2024 | XReal label-to-image LDM proposed | AUC | 0.78 | conditioning=pathology-label-to-image | XReal: Realistic Anatomy and Pathology-Aware X-ray Generation via Controllable Diffusion ModelSource quoteL221: Another experiment was conducted to evaluate the choice of using a label-to-image LDM in XReal instead of a report-to-image diffusion model. For this, we compared the label-to-image LDM in XReal with the Cheff \cite{weber2023cascaded} and Roentgen \cite{chambon2022roentgen} report-to-image diffusion models. Cheff and Roentgen were trained on paired radiology reports and images from the MIMIC dataset, while our LDM was trained on paired pathology labels and X-ray images. The results show that the label-to-image LDM outperformed the report-to-image models, achieving the highest F_1 score of 0.59 and an AUC score of 0.78 (second only to Roentgen \cite{chambon2022roentgen}). This suggests that longer prompts or reports do not necessarily improve pathology manifestation. While radiology reports provide more detailed prompts, they may not enhance accuracy in these models. These findings support our decision to use a label-to-image LDM in XReal, where text provides only pathology label p, and all spatial information is conveyed through segmentation masks m_a and m_p. |
| 2024 | Disentangled Dense Fusion proposed | AUC Macro Avg | 0.99 | params=7B · text_encoder=Llama 2 7B · image_encoder=DINOv2 | DF-DM: A foundational process model for multimodal data fusion in the artificial intelligence eraSource quoteL437: Disentangled Dense Fusion (Ours) │ 0.94 │ 0.99 |
| 2024 | Disentangled Dense Fusion proposed | AUC Macro Avg | 0.84 | params=7B · classes=4 · text_encoder=Llama 2 7B · image_encoder=DINOv2 | DF-DM: A foundational process model for multimodal data fusion in the artificial intelligence eraSource quoteL454: Disentangled Dense Fusion (Ours) │ 0.80 │ 0.84 |
| 2024 | Hard-CFT (Sex CFs) proposed | AUC | 75.4% | split: test · counterfactuals=sex | Mitigating Attribute Amplification in Counterfactual Image GenerationSource quoteL111: Hard-CFT │ \unint{75.4 {(\downarrow 18.4)}} │ \interv{79.6 {(\downarrow 20.0)}} │ \unint{89.8 {(\downarrow 4.4)}} |
| 2024 | Soft-CFT (Sex CFs) proposed | AUC | 92.4% | split: test · counterfactuals=sex | Mitigating Attribute Amplification in Counterfactual Image GenerationSource quoteL112: Soft-CFT │ \unint{92.4 {(\downarrow 1.4)}} │ \interv{90.0 {(\downarrow 9.6)}} │ \unint{94.0 {(\downarrow 0.2)}} |
| 2024 | Hard-CFT (Sex CFs) proposed | AUC | 79.6% | split: test · counterfactuals=sex | Mitigating Attribute Amplification in Counterfactual Image GenerationSource quoteL111: Hard-CFT │ \unint{75.4 {(\downarrow 18.4)}} │ \interv{79.6 {(\downarrow 20.0)}} │ \unint{89.8 {(\downarrow 4.4)}} |
| 2024 | Soft-CFT (Sex CFs) proposed | AUC | 90.0% | split: test · counterfactuals=sex | Mitigating Attribute Amplification in Counterfactual Image GenerationSource quoteL112: Soft-CFT │ \unint{92.4 {(\downarrow 1.4)}} │ \interv{90.0 {(\downarrow 9.6)}} │ \unint{94.0 {(\downarrow 0.2)}} |
| 2024 | Logistic Regression (text-only) baseline | AUC Macro Avg | 0.92 | input=text-only · model=logistic regression | DF-DM: A foundational process model for multimodal data fusion in the artificial intelligence eraSource quoteL422: For the disease classification, results can be seen in Table 5. The best performing model was the logistic regression using only text data reaching a macro AUC of 0.92 and the fusion model using the neural network with an accuracy of 0.80. These results are comparable with related work results for clinical diagnosis using MIMIC CXR, surpassing the macro AUC results reported in literature archiving 0.89 \cite{90, 91}. |
| 2024 | RadFM baseline | Macro-AUC↑ | 0.536 | MultiMedEval image classification; official dataset split; five conditions extracted fr… | MultiMedEval: A Benchmark and a Toolkit for Evaluating Medical Vision-Language ModelsSource quoteL196: 0.536 |
| 2023 | Classifier trained on D_distill proposed | f-\theta (class) AUC | 0.810 | split: test · subset=40,000 training images · backbone=DenseNet-121 · test_size=3,101 images | Privacy Distillation: Reducing Re-identification Risk of Multimodal Diffusion ModelsSource quoteL203: D-distill │ 1.34 % │ 0.810 │ 0.611-0.272 |
| 2023 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) proposed | AUC | 79.53% | split: test · fine-tuned · privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteL41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2023 | Proposed graph embeddings proposed | AUC | .823 | hidden-size=2048 · graph-attention-layers=12 | Knowledge Graph Embeddings for Multi-lingual Structured Representations of Radiology ReportsSource quoteL118: AUC │ .837 │ .885 │ .862 │ .807 │ .839 │ .823 │ .802 │ .815 │ \textBF{.819} |
| 2023 | M-FLAG proposed | AUC | 69.5% | fine-tuned · labeled-data=1% | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteL112: M-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
| 2023 | Proposed instrumental variable learning framework proposed | Mean AUC | 0.812 | Mean AUC across the abnormalities listed in the comparison table. | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteL254: Mean AUC │ 0.807 │ 0.746 │ 0.805 │ 0.812 |
| 2023 | CLIP without X-TRA retrieval augmentation ablation | Avg AUC | .80 | model=CLIP · backbone=CLIP · augmentation=no X-TRA retrieval augmentation | X-TRA: Improving Chest X-ray Tasks with Cross-Modal Retrieval AugmentationSource quoteL153: CLIP │ \ding{55} │ .77 │ .65 │ .71 │ .67 │ .62 │ .85 │ .73 │ .61 │ .72 │ .75 │ .80 │ .59 │ .51 │ .83 │ .70 │ .80 |
| 2023 | Classifier trained on D_real baseline | f-\theta (class) AUC | 0.863 | split: test · subset=3,101 images · backbone=DenseNet-121 | Privacy Distillation: Reducing Re-identification Risk of Multimodal Diffusion ModelsSource quoteL201: D-real │ 0.863 │ 0.698-0.259 |
| 2023 | Classifier trained on D_synth baseline | f-\theta (class) AUC | 0.830 | split: test · subset=40,000 training images · backbone=DenseNet-121 · test_size=3,101 images | Privacy Distillation: Reducing Re-identification Risk of Multimodal Diffusion ModelsSource quoteL202: D-synth │ 4.24 % │ 0.830 │ 0.645-0.219 |
| 2023 | Non-private fine-tuned NFNet-F0 (ImageNet-21K pre-trained) baseline | AUC | 81.14% | split: test · fine-tuned · privacy=non-private · backbone=NFNet-F0 · pretraining=ImageNet-21K | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteL41: As shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2023 | Img only baseline | AUC | .807 | modality=image-only | Knowledge Graph Embeddings for Multi-lingual Structured Representations of Radiology ReportsSource quoteL118: AUC │ .837 │ .885 │ .862 │ .807 │ .839 │ .823 │ .802 │ .815 │ \textBF{.819} |
| 2023 | MVC-NET baseline | Mean AUC | 0.807 | Mean AUC across the abnormalities listed in the comparison table; reported alongside th… | Instrumental Variable Learning for Chest X-ray ClassificationSource quoteL254: Mean AUC │ 0.807 │ 0.746 │ 0.805 │ 0.812 |
| 2022 | Unweighted and weighted bagging models proposed | AUC | 0.77 | split: test · fine-tuned · fusion=model-level bagging · evaluation=average over 1000 epochs · aggregation=unweighted and weighted | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL130: We present the model testing results of our fusion strategies in Table~\ref{tab:Fusion strategies tested on MIMIC data} for MIMIC-CXR and Table~\ref{tab:Fusion strategies tested on Emory data} of Appendix~ \ref{appendix:second} for Emory-CXR. For testing on MIMIC-CXR, the unweighted and weighted bagging models have the best AUC score (0.77), F1-score (0.54), AUPRC (0.56), and balanced accuracy (0.70). Since the Xception model performs the best among the base models, we use the Xception model in the data-level fusion strategy. The stacking model using the random forest as a meta-model performs the best among the other stacking models; however, it does not outperform the Xception basemodel. |
| 2022 | Probabilistic Integration of Object Level Annotations (DenseNet121, base model) ablation | AUC | 0.807 | split: test · stage=I · backbone=DenseNet121 | Probabilistic Integration of Object Level Annotations in Chest X-ray ClassificationSource quoteL173: DenseNet121 │ Base model │ 0.807 │ 0.25 |
| 2022 | Xception base model baseline | AUC | 0.76 | split: test · fine-tuned · split-unit=patient-level · pretraining-dataset=CheXpert | Early Diagnosis of Chronic Obstructive Pulmonary Disease from Chest X-Rays using Transfer Learning and Fusion StrategiesSource quoteL126: We present the results of four different state-of-the-art CNN models tested on MIMIC-CXR and Emory-CXR in Table~\ref{tab:Base models tested on MIMIC-IV data} and Table~\ref{tab:Base models tested on Emory data} of Appendix~\ref{appendix:Basemodel}. The Xception base model yields the best AUC score (0.76), F1-score (0.54), AUPRC (0.54), and balanced accuracy (0.69) during the internal testing on MIMIC-CXR; however, the performance of the four base models is relatively similar. Further, when performing external testing on Emory-CXR, the Xception base model attains the best performance. Additionally, the performance of the Xception base model on both MIMIC-CXR and Emory-CXR is very similar, demonstrating that our fine-tuned model does not overfit on the training data. The detailed results with precision and recall are listed in Supplementary Table B1 to B2. |
| 2021 | Variational knowledge distillation proposed | AUC | 0.758 | class=Cardiomegaly · training-modality=EHRs · inference-modality=X-rays | Variational Knowledge Distillation for Disease Classification in Chest X-RaysSource quoteL166: Cardiomegaly │ 0.889 │ 0.892 │ 0.810 │ 0.893 │ 0.899 │ 0.803 │ 0.837 │ 0.851 │ 0.739 │ 0.758 |
| 2020 | ranking-dot-semi proposed | AUC (0 vs 1,2,3) | 0.82 | split: test · view=frontal · cohort=CHF pulmonary-edema | Joint Modeling of Chest Radiographs and Radiology Reports for Pulmonary Edema AssessmentSource quoteL125: ranking-dot-semi │ 0.82 │ 0.81 │ 0.90 |
| 2020 | ranking-dot-semi proposed | AUC (0,1 vs 2,3) | 0.81 | split: test · view=frontal · cohort=CHF pulmonary-edema | Joint Modeling of Chest Radiographs and Radiology Reports for Pulmonary Edema AssessmentSource quoteL125: ranking-dot-semi │ 0.82 │ 0.81 │ 0.90 |
| 2020 | ranking-dot-semi proposed | AUC (0,1,2 vs 3) | 0.90 | split: test · view=frontal · cohort=CHF pulmonary-edema | Joint Modeling of Chest Radiographs and Radiology Reports for Pulmonary Edema AssessmentSource quoteL125: ranking-dot-semi │ 0.82 │ 0.81 │ 0.90 |
| 2020 | Pre-trained DenseNet121 on Cycle-GAN-mapped OOD radiographs proposed non-standard slice | AUC | 0.75 | split: test · subset=OOD · backbone=DenseNet121 · adaptation=CycleGAN | Computer-aided abnormality detection in chest radiographs in a clinical setting via domain-adaptationSource quoteL373: AUC │ 0.98 │ 0.79 │ 0.87 │ 0.73 │ 0.75 |
| 2020 | image-only ablation | AUC (0 vs 1,2,3) | 0.74 | split: test · view=frontal · cohort=CHF pulmonary-edema | Joint Modeling of Chest Radiographs and Radiology Reports for Pulmonary Edema AssessmentSource quoteL121: \texttt{image-only} │ 0.74 │ 0.73 │ 0.78 |
| 2020 | image-only ablation | AUC (0,1 vs 2,3) | 0.73 | split: test · view=frontal · cohort=CHF pulmonary-edema | Joint Modeling of Chest Radiographs and Radiology Reports for Pulmonary Edema AssessmentSource quoteL121: \texttt{image-only} │ 0.74 │ 0.73 │ 0.78 |
| 2020 | image-only ablation | AUC (0,1,2 vs 3) | 0.78 | split: test · view=frontal · cohort=CHF pulmonary-edema | Joint Modeling of Chest Radiographs and Radiology Reports for Pulmonary Edema AssessmentSource quoteL121: \texttt{image-only} │ 0.74 │ 0.73 │ 0.78 |
| 2020 | VisualBERT baseline | averaged AUC | 0.987 | split: test · configuration=default | A Comparison of Pre-trained Vision-and-Language Models for Multimodal Representation Learning across Medical Images and ReportsSource quoteL114: We use the held-out test split of MIMIC-CXR to make a more comprehensive comparison of 4 V+L models. The results are revealed in the default column of Table \ref{mimic}. VisualBERT yields the best averaged AUC of 0.987, followed by 0.985 using UNITER and 0.984 using LXMERT. PixelBERT only achieves a moderate AUC of 0.953 due to the absence of the pre-training. When comparing the performance on different findings, we surprisingly find that VisualBERT achieves the best results on 11 out of 13 findings. Although VisualBERT adopts the least pre-training tasks and the simplest model architecture, we believe the introduction of task-specific training for VQA contributes to this optimal performance. LXMERT outperforms others in Pleural Others and Fracture, which are the two least prevalent findings. We also notice that it is harder to identify Enlarged Cardiomediastinum compared with other abnormalities. We attribute this to the absence of lateral view X-ray images in our training set in that the cardiomediastinum contour is easier to recognize from a lateral view. Moreover, it is as expected that UNITER does not have a supreme performance in our study as we adopt the base version of UNITER. UNITER\textsubscript{larger} is much larger than UNITER\textsubscript{base} in both number of layers and trainable parameters. We believe that UNITER\textsubscript{larger} can achieve better results given its phenomenal performance in general domain. |
| 2020 | UNITER baseline | averaged AUC | 0.985 | split: test · configuration=default | A Comparison of Pre-trained Vision-and-Language Models for Multimodal Representation Learning across Medical Images and ReportsSource quoteL114: We use the held-out test split of MIMIC-CXR to make a more comprehensive comparison of 4 V+L models. The results are revealed in the default column of Table \ref{mimic}. VisualBERT yields the best averaged AUC of 0.987, followed by 0.985 using UNITER and 0.984 using LXMERT. PixelBERT only achieves a moderate AUC of 0.953 due to the absence of the pre-training. When comparing the performance on different findings, we surprisingly find that VisualBERT achieves the best results on 11 out of 13 findings. Although VisualBERT adopts the least pre-training tasks and the simplest model architecture, we believe the introduction of task-specific training for VQA contributes to this optimal performance. LXMERT outperforms others in Pleural Others and Fracture, which are the two least prevalent findings. We also notice that it is harder to identify Enlarged Cardiomediastinum compared with other abnormalities. We attribute this to the absence of lateral view X-ray images in our training set in that the cardiomediastinum contour is easier to recognize from a lateral view. Moreover, it is as expected that UNITER does not have a supreme performance in our study as we adopt the base version of UNITER. UNITER\textsubscript{larger} is much larger than UNITER\textsubscript{base} in both number of layers and trainable parameters. We believe that UNITER\textsubscript{larger} can achieve better results given its phenomenal performance in general domain. |
| 2020 | LXMERT baseline | averaged AUC | 0.984 | split: test · configuration=default | A Comparison of Pre-trained Vision-and-Language Models for Multimodal Representation Learning across Medical Images and ReportsSource quoteL114: We use the held-out test split of MIMIC-CXR to make a more comprehensive comparison of 4 V+L models. The results are revealed in the default column of Table \ref{mimic}. VisualBERT yields the best averaged AUC of 0.987, followed by 0.985 using UNITER and 0.984 using LXMERT. PixelBERT only achieves a moderate AUC of 0.953 due to the absence of the pre-training. When comparing the performance on different findings, we surprisingly find that VisualBERT achieves the best results on 11 out of 13 findings. Although VisualBERT adopts the least pre-training tasks and the simplest model architecture, we believe the introduction of task-specific training for VQA contributes to this optimal performance. LXMERT outperforms others in Pleural Others and Fracture, which are the two least prevalent findings. We also notice that it is harder to identify Enlarged Cardiomediastinum compared with other abnormalities. We attribute this to the absence of lateral view X-ray images in our training set in that the cardiomediastinum contour is easier to recognize from a lateral view. Moreover, it is as expected that UNITER does not have a supreme performance in our study as we adopt the base version of UNITER. UNITER\textsubscript{larger} is much larger than UNITER\textsubscript{base} in both number of layers and trainable parameters. We believe that UNITER\textsubscript{larger} can achieve better results given its phenomenal performance in general domain. |
| 2020 | Pre-trained DenseNet121, no adaptation baseline non-standard slice | AUC | 0.73 | split: test · subset=OOD · backbone=DenseNet121 · adaptation=none | Computer-aided abnormality detection in chest radiographs in a clinical setting via domain-adaptationSource quoteL373: AUC │ 0.98 │ 0.79 │ 0.87 │ 0.73 │ 0.75 |