MIMIC-CXR

263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API

Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)

Proposed/measured results on test (including prose scores where split is implicit).

68.772.676.580.32024M-FLAG: 69.5 (2023)DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained): 79.53 (2023)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 13 of 13 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2026MEDA (QMS+PDI) proposedAccuracy79.4%multi-round · backbone=LLaVA-Med-1.5 · question_set=MedHEval · method_variant=QMS+PDIMEDA: Medical-Oriented Activation Editing for Hallucination Mitigation in Medical Large Vision-Language Model
Source quote
L398: 79.4
2025DLDM (disentangled latent diffusion model) proposedEffectiveness Accuracy89.2%split: test · intervention=do(A=black)AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual Analysis
Source quote
L605: DLDM │ 89.2 │ 92.0 │ 93.7
2025R-CLIP-opt proposedAccuracy0.780subset=1% · backbone=CLIPCRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest Radiographs
Source quote
L198: R-CLIP-opt (ours) │ Generated report │ 1% │ 0.848 │ 0.780
2025CoD proposedHorizontal lesion location accuracy0.514split: test · attribute=horizontal-lesion-location · evaluator=AttriBertA Chain of Diagnosis Framework for Accurate and Explainable Radiology Report Generation
Source quote
L305: We compare our model with SOTA RRG methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, RGRG~\cite{TMK23}, R2GenGPT~\cite{WLW23b}, PromptMRG~\cite{JCL24}, and I3+C2FD~\cite{LTC24}. Moreover, we have added generalist foundation models for comparison, including Med-Flamingo~\cite{MHW23}, RadFM~\cite{WZZ23}, InternVL~\cite{CWW24}, LLaVA-Med~\cite{LWZ24}, and MedDr~\cite{HNW24}, which are trained to tackle various medical tasks rather than RRG alone. Table~\ref{tab:results_sota} shows the results on both IU X-Ray and MIMIC-CXR. First of all, we can see from the table that the proposed CoD obtains the best performance on most of the entries. To be specific, CoD obtains the best results on 11 out of 12 entries within CE metrics, demonstrating its superiority in generating clinically accurate reports. Notably, our method outperforms the other methods considerably in attribute accuracy, thanks to the effective guidance of QA prompts. For example, our method achieves 0.514 and 0.404 of horizontal lesion location accuracy on MIMIC and IU, which have gained 19.3% and 16.8% improvement respectively over the second best method PromptMRG. In terms of NLG metrcis, CoD obtains best results on four out of six entries, indicating the superior capability of LLMs in generating fluent and relevant texts. Interestingly, the performance of generalist foundation models are far behind that of specialists, where MedDr performs the best among generalists. This is understandable as generalists are supposed to deal with a number of tasks as well as out-of-domain data, which inevitably degrades their competitiveness on a specific task/data.
2025AURAD-generated data augmentation proposeddisease classification accuracy gain+3.78%Cross-domain disease classification evaluation; training augmented with AURAD-generated…AURAD: Anatomy-Pathology Unified Radiology Synthesis with Progressive Representations
Source quote
L264: Cross-domain performance is evaluated on three external datasets: ChestX-ray14 and VinDr-CXR for lesion detection, and MIMIC-CXR for disease classification (Tables~\ref{tab:det_result} and~\ref{tab:cls_result}). Augmenting training with AURAD -generated samples improves performance, with gains of +5.02% mAP on ChestX-ray14, +1.40% on VinDr-CXR, and +3.78% classification accuracy on MIMIC-CXR. These results highlight the robustness of our approach and its ability to mitigate dataset-specific overfitting.
2024D-KD (RadBERT-Roberta-4m-document, contrastive) proposed non-standard sliceAccuracy85.52%split: test · params=4m · subset=p11 high-confidence-filtered test documents · backbone=RadBERT-Roberta-4m-documentIntegrating ChatGPT into Secure Hospital Networks: A Case Study on Improving Radiology Report Analysis
Source quote
L176: \begin{tabular}[c]{@{}c@{}}RadBERT-Roberta\\-4m-document\\contrastive │ \begin{tabular}[c]{@{}c@{}}85.52\\(+ 0.35) │ \begin{tabular}[c]{@{}c@{}}0.858\\(+0.026) │ \begin{tabular}[c]{@{}c@{}}0.840\\(-0.012) │ \begin{tabular}[c]{@{}c@{}}0.901\\(+0.055)
2024MDAgents (Adaptive; GPT-4o-mini) proposedAccuracy56.0%split: test · 0-shotMDAgents: An Adaptive Collaboration of LLMs for Medical Decision-Making
Source quote
L525: \shortcolorbox{MDAgents (Ours)} │ 75.0 │ 89.0 │ 59.0 │ 67.0 │ 56.0
2024Fair Diagnosis (ResNet50) proposedACC84.67%split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=genderFair Diagnosis: Leveraging Causal Modeling to Mitigate Medical Bias
Source quote
L278: Resnet50 │ 84.67 │ 62.46 │ 1.78 │ 2.39 │ 1.19
2023ELIXR-B proposedAccuracy62.5%split: test · section=impressionELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encoders
Source quote
L557: On more challenging text-generation tasks, ELIXR-B demonstrated overall accuracies of 58.7% and 54.8% on two visual question answering (VQA) datasets, VQA-RAD (CXR-only questions) (Table 5) and MIMIC-CXR test (Table 6), as well as 62.5% on report quality assurance (QA) on
20224-class IC CoPlan (Proposed) proposedClinical accuracy Micro-F58.6labeler=CheXbert · method-variant=4-class IC CoPlan · generation-setting=E2EFactual Accuracy is not Enough: Planning Consistent Description Order for Radiology Report Generation
Source quote
L497: *58.6
2021Reweighting-NURD proposedaccuracy61%nuisance=non-lung patchesOut-of-distribution Generalization in the Presence of Nuisance-Induced Spurious Correlations
Source quote
L464: Reweighting-\gls{nurd} uses the non-lung patches to adjust for the spurious correlation and achieves an accuracy of 61%, a large improvement over \gls{erm}.
2020CVSE + mutual exclusiveness proposedAccuracy0.863split: test · subset=abnormal findings · aggregation=macro-average across 14 diseasesLearning Visual-Semantic Embeddings for Reporting Abnormal Findings on Chest X-rays
Source quote
L204: Macro-Average │ 0.863 │ 0.317 │ 0.224 │ 0.850 │ 0.261 │ 0.157
2020Pre-trained DenseNet121 on Cycle-GAN-mapped OOD radiographs proposed non-standard sliceAccuracy0.74split: test · subset=OOD · backbone=DenseNet121 · adaptation=CycleGANComputer-aided abnormality detection in chest radiographs in a clinical setting via domain-adaptation
Source quote
L374: Accuracy │ 0.95 │ 0.79 │ 0.90 │ 0.71 │ 0.74