MIMIC-CXR
263 papers · 775 extracted observations · report generation · Markdown · CSV · JSON API
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines)
Proposed/measured results on test (including prose scores where split is implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DP-SGD-fine-tuned NFNet-F0 (ImageNet-21K pre-trained) SOTA frontier | 79.53% | 2023-08-01 | privacy=DP-SGD, ε=8 · backbone=NFNet-F0 · pretraining=ImageNet-21K · ε=8; AUC averaged over all classes. Evaluation uses the 80-10-10 train-validation-tes… | Unlocking Accuracy and Fairness in Differentially Private Image ClassificationSource quoteAs shown in \Cref{fig:main-accuracy}, our fine-tuned image classifiers are able to reach high accuracies. Specifically, on CheXpert, our model fine-tuned with differential privacy at \varepsilon=8 obtains 89.24% AUC, to be compared to 89.97% for the pre-trained model fine-tuned without privacy, and to 93.0% for the state-of-the-art, achieved by ensembles of models trained without any privacy constraints \cite{DBLP:conf/iccv/Yuan0SY21}. Similar results also hold for MIMIC-CXR where our private model obtains 79.53% AUC at \varepsilon=8, 81.14% without privacy, and for which the published state-of-the-art obtains 84.04% \cite{KamalZNH22} by using a more complicated architecture that segments the images as part of its processing. Remarkably, when imposing stringent privacy guarantees, e.g. a privacy budget of only \varepsilon=1, it is still possible to obtain useful levels of accuracy, with an AUC of 86.34% on CheXpert and 76.40% on MIMIC-CXR. |
| 2 | M-FLAG SOTA frontier | 69.5% | 2023-07-01 | labeled-data=1% · Fine-tuned using 1% labeled data. | M-FLAG: Medical Vision-Language Pre-training with Frozen Language Models and Latent Space Geometry OptimizationSource quoteM-FLAG │ 25.6 │ 69.5 │ 74.8 │ 80.2 │ 64.4 │ 71.4 │ 78.1 │ 62.2 │ 71.6 │ 78.7 |
Showing 13 of 13 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | MEDA (QMS+PDI) proposed | Accuracy | 79.4% | multi-round · backbone=LLaVA-Med-1.5 · question_set=MedHEval · method_variant=QMS+PDI | MEDA: Medical-Oriented Activation Editing for Hallucination Mitigation in Medical Large Vision-Language ModelSource quoteL398: 79.4 |
| 2025 | DLDM (disentangled latent diffusion model) proposed | Effectiveness Accuracy | 89.2% | split: test · intervention=do(A=black) | AI Alignment in Medical Imaging: Unveiling Hidden Biases Through Counterfactual AnalysisSource quoteL605: DLDM │ 89.2 │ 92.0 │ 93.7 |
| 2025 | R-CLIP-opt proposed | Accuracy | 0.780 | subset=1% · backbone=CLIP | CRRG-CLIP: Automatic Generation of Chest Radiology Reports and Classification of Chest RadiographsSource quoteL198: R-CLIP-opt (ours) │ Generated report │ 1% │ 0.848 │ 0.780 |
| 2025 | CoD proposed | Horizontal lesion location accuracy | 0.514 | split: test · attribute=horizontal-lesion-location · evaluator=AttriBert | A Chain of Diagnosis Framework for Accurate and Explainable Radiology Report GenerationSource quoteL305: We compare our model with SOTA RRG methods, including R2Gen~\cite{CSC20}, M2TR~\cite{NGF21}, MKSG~\cite{YWG22}, CliBert~\cite{YaP22}, CVT2Dis.~\cite{NDK22}, M2KT~\cite{YWG23}, METrans.~\cite{WLW23}, KiUT~\cite{HZZ23}, DCL~\cite{LLC23}, RGRG~\cite{TMK23}, R2GenGPT~\cite{WLW23b}, PromptMRG~\cite{JCL24}, and I3+C2FD~\cite{LTC24}. Moreover, we have added generalist foundation models for comparison, including Med-Flamingo~\cite{MHW23}, RadFM~\cite{WZZ23}, InternVL~\cite{CWW24}, LLaVA-Med~\cite{LWZ24}, and MedDr~\cite{HNW24}, which are trained to tackle various medical tasks rather than RRG alone. Table~\ref{tab:results_sota} shows the results on both IU X-Ray and MIMIC-CXR. First of all, we can see from the table that the proposed CoD obtains the best performance on most of the entries. To be specific, CoD obtains the best results on 11 out of 12 entries within CE metrics, demonstrating its superiority in generating clinically accurate reports. Notably, our method outperforms the other methods considerably in attribute accuracy, thanks to the effective guidance of QA prompts. For example, our method achieves 0.514 and 0.404 of horizontal lesion location accuracy on MIMIC and IU, which have gained 19.3% and 16.8% improvement respectively over the second best method PromptMRG. In terms of NLG metrcis, CoD obtains best results on four out of six entries, indicating the superior capability of LLMs in generating fluent and relevant texts. Interestingly, the performance of generalist foundation models are far behind that of specialists, where MedDr performs the best among generalists. This is understandable as generalists are supposed to deal with a number of tasks as well as out-of-domain data, which inevitably degrades their competitiveness on a specific task/data. |
| 2025 | AURAD-generated data augmentation proposed | disease classification accuracy gain | +3.78% | Cross-domain disease classification evaluation; training augmented with AURAD-generated… | AURAD: Anatomy-Pathology Unified Radiology Synthesis with Progressive RepresentationsSource quoteL264: Cross-domain performance is evaluated on three external datasets: ChestX-ray14 and VinDr-CXR for lesion detection, and MIMIC-CXR for disease classification (Tables~\ref{tab:det_result} and~\ref{tab:cls_result}). Augmenting training with AURAD -generated samples improves performance, with gains of +5.02% mAP on ChestX-ray14, +1.40% on VinDr-CXR, and +3.78% classification accuracy on MIMIC-CXR. These results highlight the robustness of our approach and its ability to mitigate dataset-specific overfitting. |
| 2024 | D-KD (RadBERT-Roberta-4m-document, contrastive) proposed non-standard slice | Accuracy | 85.52% | split: test · params=4m · subset=p11 high-confidence-filtered test documents · backbone=RadBERT-Roberta-4m-document | Integrating ChatGPT into Secure Hospital Networks: A Case Study on Improving Radiology Report AnalysisSource quoteL176: \begin{tabular}[c]{@{}c@{}}RadBERT-Roberta\\-4m-document\\contrastive │ \begin{tabular}[c]{@{}c@{}}85.52\\(+ 0.35) │ \begin{tabular}[c]{@{}c@{}}0.858\\(+0.026) │ \begin{tabular}[c]{@{}c@{}}0.840\\(-0.012) │ \begin{tabular}[c]{@{}c@{}}0.901\\(+0.055) |
| 2024 | MDAgents (Adaptive; GPT-4o-mini) proposed | Accuracy | 56.0% | split: test · 0-shot | MDAgents: An Adaptive Collaboration of LLMs for Medical Decision-MakingSource quoteL525: \shortcolorbox{MDAgents (Ours)} │ 75.0 │ 89.0 │ 59.0 │ 67.0 │ 56.0 |
| 2024 | Fair Diagnosis (ResNet50) proposed | ACC | 84.67% | split: test · α=1.0 · η=0.2 · backbone=ResNet50 · train_test_split=90/10 · sensitive_attribute=gender | Fair Diagnosis: Leveraging Causal Modeling to Mitigate Medical BiasSource quoteL278: Resnet50 │ 84.67 │ 62.46 │ 1.78 │ 2.39 │ 1.19 |
| 2023 | ELIXR-B proposed | Accuracy | 62.5% | split: test · section=impression | ELIXR: Towards a general purpose X-ray artificial intelligence system through alignment of large language models and radiology vision encodersSource quoteL557: On more challenging text-generation tasks, ELIXR-B demonstrated overall accuracies of 58.7% and 54.8% on two visual question answering (VQA) datasets, VQA-RAD (CXR-only questions) (Table 5) and MIMIC-CXR test (Table 6), as well as 62.5% on report quality assurance (QA) on |
| 2022 | 4-class IC CoPlan (Proposed) proposed | Clinical accuracy Micro-F | 58.6 | labeler=CheXbert · method-variant=4-class IC CoPlan · generation-setting=E2E | Factual Accuracy is not Enough: Planning Consistent Description Order for Radiology Report GenerationSource quoteL497: *58.6 |
| 2021 | Reweighting-NURD proposed | accuracy | 61% | nuisance=non-lung patches | Out-of-distribution Generalization in the Presence of Nuisance-Induced Spurious CorrelationsSource quoteL464: Reweighting-\gls{nurd} uses the non-lung patches to adjust for the spurious correlation and achieves an accuracy of 61%, a large improvement over \gls{erm}. |
| 2020 | CVSE + mutual exclusiveness proposed | Accuracy | 0.863 | split: test · subset=abnormal findings · aggregation=macro-average across 14 diseases | Learning Visual-Semantic Embeddings for Reporting Abnormal Findings on Chest X-raysSource quoteL204: Macro-Average │ 0.863 │ 0.317 │ 0.224 │ 0.850 │ 0.261 │ 0.157 |
| 2020 | Pre-trained DenseNet121 on Cycle-GAN-mapped OOD radiographs proposed non-standard slice | Accuracy | 0.74 | split: test · subset=OOD · backbone=DenseNet121 · adaptation=CycleGAN | Computer-aided abnormality detection in chest radiographs in a clinical setting via domain-adaptationSource quoteL374: Accuracy │ 0.95 │ 0.79 │ 0.90 │ 0.71 │ 0.74 |