| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | KnowGPT SOTA frontier | 78.1% | 2024-01-01 | llm-tuning=none · Supplementary comparison with fine-tuned LLMs; the paper says KnowGPT uses no LLM tun… | KnowGPT: Knowledge Graph based Prompting for Large Language ModelsSource quote\texttt{KnowGPT} │ 81.8% │ 92.4% │ 78.1% |
| 2 | LLaMA 3.1-8B (trained) + GroupRAG (+2 variants) | 71.75% | 2026-03-01 | params=8B · Separate 400-question information-dense test set. The trained small-language-model va… | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL3.1-8B(trained) │ 52.75 │ 61.50 │ 58.25 │ 71.75 |
| 3 | MedGENIE-FID-Flan-T5 | 53.1% | 2024-01-01 | reader=Fusion-in-Decoder · backbone=Flan-T5 · Fine-tuned Fusion-In-Decoder reader grounded on PMC-LLaMA-generated contexts; supervi… | To Generate or to Retrieve? On the Effectiveness of Artificial Contexts for Medical Open-Domain Question AnsweringSource quoteMedGENIE-FID-Flan-T5 │ G (PMC-LLaMA) │ Fine-tuned │ 250M │ 53.1 |
| 4 | Input-driven saliency pruning + fine-tuning (LLaMA 3 8B, 67% pruned) | 20.59% | 2025-06-01 | params=8B · pruning=67% · backbone=LLaMA 3 8B · LightEval medical-QA evaluation; fine-tuned (FT) variant. | Enabling On-Device Medical AI Assistants via Input-Driven Saliency AdaptationSource quoteLLaMA\,3\,8B │ 67% Pruned (FT) │ 5.58 │ 29.45% │ 20.59% │ 43.15% |
Showing 150 of 150 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2026 | FV-8B proposed | Accuracy | 86.2% | split: test · params=8B | Fathom-Vaidya: Advancing Medical Reasoning with Rubric-Based RewardsSource quoteL667: 86.2 (+6.4%) |
| 2026 | SelectKV-90 (SKV-90) proposed | Accuracy | 62.0% | params=4B | Selective and Hybrid-State Communication for Latent Multi-Agent SystemsSource quoteL405: 62.0 |
| 2026 | HyLaMAS (Qwen3.5-4B) proposed | Accuracy | 77.0% | params=4B | Selective and Hybrid-State Communication for Latent Multi-Agent SystemsSource quoteL577: 77.0 |
| 2026 | HyLaMAS (Qwen3.5-9B) proposed | Accuracy | 88.0% | params=9B | Selective and Hybrid-State Communication for Latent Multi-Agent SystemsSource quoteL581: 88.0 |
| 2026 | HSIR-SFT (All) proposed | Accuracy | 45.33 | split: test · 0-shot · params=1.5B · backbone=Qwen2.5-1.5B · iterations=1 | Better, Faster: Harnessing Self-Improvement in Large Reasoning ModelsSource quoteL220: ReST (EM) │ 41.63 │ 1,424 │ 69.75 │ 1,382 \textbf{\texttt{HSIR-SFT} (All)} │ \bf 45.33 │ \bf 1,064 │ \bf 71.72 │ \bf 1,181 |
| 2026 | LLM with E1 few-shot prompt intervention based on nonspecific systemic symptoms proposed | benchmark accuracy | 84.3% | few-shot · subset=analyzed cases | VeriLLMed: Interactive Visual Debugging of Medical Large Language Models with Knowledge GraphsSource quoteL657: Under this limited prompt modification, the eight previously incorrect cases associated with this error pattern were corrected, and the benchmark accuracy on the analyzed cases increased from 81.5% to 84.3%. |
| 2026 | LLM with E2 few-shot prompt intervention based on pruritus or similar dermatologic symptoms proposed | benchmark accuracy | 85.5% | few-shot · subset=analyzed set | VeriLLMed: Interactive Visual Debugging of Medical Large Language Models with Knowledge GraphsSource quoteL685: Under this limited intervention, the previously incorrect cases matching this pattern were corrected, and the benchmark accuracy in this run increased from 81.5% to 85.5% on the analyzed set. |
| 2026 | LLaMA 3.1-8B (trained) + GroupRAG proposed | Answer accuracy | 71.75% | split: test · fine-tuned · params=8B | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL239: L3.1-8B(trained) │ 52.75 │ 61.50 │ 58.25 │ 71.75 |
| 2026 | LLaMA 3.1-8B (base) + GroupRAG proposed | Answer accuracy | 61.00% | split: test · params=8B | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL238: L3.1-8B(base) │ 48.25 │ 54.50 │ 53.50 │ 61.00 |
| 2026 | HCQR proposed | answer accuracy | 75.0 | final-context-budget=15 documents · model-configurations=average across 4 | Hypothesis-Conditioned Query Rewriting for Decision-Useful RetrievalSource quoteL408: HCQR (ours) │ 63.4 │ 73.0 │ 77.9 │ 85.8 │ 75.0 │ 68.6 │ 79.7 │ 85.4 │ 90.6 │ 81.1 |
| 2026 | PRA (trained reward agent; search enabled) proposed | Acc. | 80.8 | params=4B | Process Reward Agents for Steering Knowledge-Intensive ReasoningSource quoteL244: PRA (ours) │ \checkmark │ \checkmark │ PRA │ 64(B × b) │ 80.8 |
| 2026 | EDCO proposed | Accuracy | 36.7% | params=3B | EDCO: Dynamic Curriculum Orchestration for Domain-specific Large Language Model Fine-tuningSource quoteL192: MedQA │ 32.1 │ 32.9 │ 35.1 │ 32.4 │ 24.6 │ 36.7 |
| 2026 | PolicyAlign (Qwen2.5-7B-Instruct) proposed | Accuracy | 0.5727 | params=7B · backbone=Qwen2.5-7B-Instruct | PolicyAlign: Direct Policy-Based Safety Alignment for Large Language ModelsSource quoteL308: Medical safety. Figure~\ref{fig:medical_results} shows that PolicyAlign improves medical safety while largely preserving medical capability. On MedSafetyBench, PolicyAlign reduces the Harmfulness Score from 1.753 to 1.100. Moreover, PolicyAlign achieves the best results on CARES across all three metrics. These results suggest that PolicyAlign improves safety beyond simple refusal behavior, extending to more nuanced medical safety classification and response generation. Meanwhile, PolicyAlign preserves medical capability much better than SFT. For example, on MedQA, SFT drops to 0.4595, whereas PolicyAlign reaches 0.5727, close to the base model's 0.5892. |
| 2026 | AlignBeam on MedLlama-3-8B proposed | accuracy | 12.7% | params=8B | ALIGNBEAM: Inference-Time Alignment Transfer via Cross-Vocabulary Logit MixingSource quoteL1674: from 13.1% to 12.7% (-0.4\,pp). Full per-strategy |
| 2026 | AgenticRag-R1 proposed | Format Acc | 92% | split: test · judge=Qwen2.5-72B · params=7B · backbone=Qwen2.5-7B-Instruct | AgenticRag-R1: Agentic Reinforcement Learning with Stack Memory for Multi-Step Reasoning, Retrieval and MemorizingSource quoteL1460: AgenticRag-R1 │ 92% │ 87% |
| 2026 | AgenticRag-R1 proposed | Answer Acc | 87% | split: test · judge=Qwen2.5-72B · params=7B · backbone=Qwen2.5-7B-Instruct | AgenticRag-R1: Agentic Reinforcement Learning with Stack Memory for Multi-Step Reasoning, Retrieval and MemorizingSource quoteL1460: AgenticRag-R1 │ 92% │ 87% |
| 2026 | ATPO (U1+U2) proposed | accuracy gain over TreePO | 0.82% | params=1.7B · backbone=Qwen3-1.7B | ATPO: ADAPTIVE TREE POLICY OPTIMIZATION FOR MULTI-TURN MEDICAL DIALOGUESource quoteL226: Our proposed ATPO achieves the highest accuracy in most settings, even surpassing GPT-4o at the 8B scale (e.g., exceeding GPT-4o on MedQA by 0.92%). This demonstrates the strong effectiveness of the method. Further, the results show that both uncertainty metrics are valuable and complementary: ATPO (U_1+U_2) generally outperforms ATPO (U_1), which in turn achieves higher accuracy than TreePO. Combining U_1 and U_2 yields the best results, with absolute gains over TreePO on MedQA of 0.82%, 1.73%, and 2.26% for the 1.7B, 4B, and 8B models, respectively. This performance improvement is partly driven by the enhanced quality of the dialogues. As shown in Appendix~\ref{effecive_analy}, the proportion of effective questions asked by the assistant steadily increases during ATPO training (Figure~\ref{effective_rate}), allowing it to gather crucial information more efficiently and solve tasks in fewer turns. |
| 2026 | ATPO (U1+U2) proposed | accuracy gain over TreePO | 1.73% | params=4B · backbone=Qwen3-4B | ATPO: ADAPTIVE TREE POLICY OPTIMIZATION FOR MULTI-TURN MEDICAL DIALOGUESource quoteL226: Our proposed ATPO achieves the highest accuracy in most settings, even surpassing GPT-4o at the 8B scale (e.g., exceeding GPT-4o on MedQA by 0.92%). This demonstrates the strong effectiveness of the method. Further, the results show that both uncertainty metrics are valuable and complementary: ATPO (U_1+U_2) generally outperforms ATPO (U_1), which in turn achieves higher accuracy than TreePO. Combining U_1 and U_2 yields the best results, with absolute gains over TreePO on MedQA of 0.82%, 1.73%, and 2.26% for the 1.7B, 4B, and 8B models, respectively. This performance improvement is partly driven by the enhanced quality of the dialogues. As shown in Appendix~\ref{effecive_analy}, the proportion of effective questions asked by the assistant steadily increases during ATPO training (Figure~\ref{effective_rate}), allowing it to gather crucial information more efficiently and solve tasks in fewer turns. |
| 2026 | ATPO (U1+U2) proposed | accuracy gain over TreePO | 2.26% | params=8B · backbone=Qwen3-8B | ATPO: ADAPTIVE TREE POLICY OPTIMIZATION FOR MULTI-TURN MEDICAL DIALOGUESource quoteL226: Our proposed ATPO achieves the highest accuracy in most settings, even surpassing GPT-4o at the 8B scale (e.g., exceeding GPT-4o on MedQA by 0.92%). This demonstrates the strong effectiveness of the method. Further, the results show that both uncertainty metrics are valuable and complementary: ATPO (U_1+U_2) generally outperforms ATPO (U_1), which in turn achieves higher accuracy than TreePO. Combining U_1 and U_2 yields the best results, with absolute gains over TreePO on MedQA of 0.82%, 1.73%, and 2.26% for the 1.7B, 4B, and 8B models, respectively. This performance improvement is partly driven by the enhanced quality of the dialogues. As shown in Appendix~\ref{effecive_analy}, the proportion of effective questions asked by the assistant steadily increases during ATPO training (Figure~\ref{effective_rate}), allowing it to gather crucial information more efficiently and solve tasks in fewer turns. |
| 2026 | ATPO proposed | accuracy difference | 0.92% | params=8B · backbone=Qwen3-8B | ATPO: ADAPTIVE TREE POLICY OPTIMIZATION FOR MULTI-TURN MEDICAL DIALOGUESource quoteL226: Our proposed ATPO achieves the highest accuracy in most settings, even surpassing GPT-4o at the 8B scale (e.g., exceeding GPT-4o on MedQA by 0.92%). This demonstrates the strong effectiveness of the method. Further, the results show that both uncertainty metrics are valuable and complementary: ATPO (U_1+U_2) generally outperforms ATPO (U_1), which in turn achieves higher accuracy than TreePO. Combining U_1 and U_2 yields the best results, with absolute gains over TreePO on MedQA of 0.82%, 1.73%, and 2.26% for the 1.7B, 4B, and 8B models, respectively. This performance improvement is partly driven by the enhanced quality of the dialogues. As shown in Appendix~\ref{effecive_analy}, the proportion of effective questions asked by the assistant steadily increases during ATPO training (Figure~\ref{effective_rate}), allowing it to gather crucial information more efficiently and solve tasks in fewer turns. |
| 2026 | SGR-LLaMA-3.3-70B proposed | accuracy | 79.81 | params=70B · backbone=LLaMA-3.3-70B | From Chains to Graphs: Self-Structured Reasoning for General-Domain LLMsSource quoteL279: SGR-LLaMA-3.3-70B │ 69.91 │ 57.50 │ 79.81 |
| 2026 | BELIEF (Qwen2.5-7B) proposed | ACC | 0.660 | split: test · 0-shot · params=7B · backbone=Qwen2.5-7B · retrieval=top-5 PubMed · sample-size=500 | BELIEF: Structured Evidence Modeling and Uncertainty-Aware Fusion for Biomedical Question AnsweringSource quoteL472: BELIEF │ 0.632 │ 0.447 │ 0.660 │ 0.645 │ 0.622 │ 0.612 |
| 2026 | StackSL (Full) proposed | Acc | 0.5962 | split: test · fine-tuned · params=4B · backbone=Qwen3-4B-Base · reference-model=Qwen3-4B | Optimal Budgeted Adaptation of Large Language ModelsSource quoteL640: 0.5962 │ 0.5922 │ 0.0045 |
| 2026 | LLaMA 3.1-8B (trained) + CoT prompting | Answer accuracy | 61.50% | split: test · fine-tuned · params=8B | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL239: L3.1-8B(trained) │ 52.75 │ 61.50 │ 58.25 │ 71.75 |
| 2026 | LLaMA 3.1-8B (trained) + Naive RAG | Answer accuracy | 58.25% | split: test · fine-tuned · params=8B | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL239: L3.1-8B(trained) │ 52.75 │ 61.50 │ 58.25 │ 71.75 |
| 2026 | LLaMA 3.1-8B (base) + CoT prompting | Answer accuracy | 54.50% | split: test · params=8B | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL238: L3.1-8B(base) │ 48.25 │ 54.50 │ 53.50 │ 61.00 |
| 2026 | LLaMA 3.1-8B (base) + Naive RAG | Answer accuracy | 53.50% | split: test · params=8B | GroupRAG: Cognitively Inspired Group-Aware Retrieval and Reasoning via Knowledge-Driven Problem StructuringSource quoteL238: L3.1-8B(base) │ 48.25 │ 54.50 │ 53.50 │ 61.00 |
| 2026 | RAG + SC | Acc. | 76.7 | params=4B | Process Reward Agents for Steering Knowledge-Intensive ReasoningSource quoteL241: × │ × │ \checkmark │ RAG + SC │ 64 │ 76.7 |
| 2026 | PRA with Qwen2.5-0.5B-Instruct | accuracy | 54.1 | params=0.5B | Process Reward Agents for Steering Knowledge-Intensive ReasoningSource quoteL184: We evaluate whether PRA enables the drop-in replacement of frozen policy models without requiring any retraining. Table~\ref{tab:policy_reward_vertical} shows that PRA, despite being trained exclusively on reasoning traces from Qwen3-4B, generalizes well across a diverse set of policy models spanning both smaller and larger sizes. In several cases, models that perform poorly under standard decoding exhibit especially large relative improvements when paired with PRA, with the largest gains observed for smaller policy models. For example, on Qwen2.5-0.5B-Instruct, PRA improves MedQA accuracy from 28.4 to 54.1, corresponding to a 90.5% relative improvement over chain-of-thought. |
| 2026 | PRA (Average) | Acc. | 77.6 | Process-level rewards aggregated post hoc by averaging; search enabled; same trained PR… | Process Reward Agents for Steering Knowledge-Intensive ReasoningSource quoteL268: PRA (Average) │ Process │ Post hoc │ \checkmark │ 77.6 |
| 2026 | RS | Accuracy | 32.9% | params=3B | EDCO: Dynamic Curriculum Orchestration for Domain-specific Large Language Model Fine-tuningSource quoteL192: MedQA │ 32.1 │ 32.9 │ 35.1 │ 32.4 │ 24.6 │ 36.7 |
| 2026 | ReST (EM) baseline | Accuracy | 41.63 | split: test · 0-shot · params=1.5B · backbone=Qwen2.5-1.5B · iterations=1 | Better, Faster: Harnessing Self-Improvement in Large Reasoning ModelsSource quoteL220: ReST (EM) │ 41.63 │ 1,424 │ 69.75 │ 1,382 \textbf{\texttt{HSIR-SFT} (All)} │ \bf 45.33 │ \bf 1,064 │ \bf 71.72 │ \bf 1,181 |
| 2026 | LLM evaluated in the VeriLLMed case study, before prompt intervention baseline | accuracy | 81.5% | Global accuracy in the original run; the same 81.5% is reported as the starting point f… | VeriLLMed: Interactive Visual Debugging of Medical Large Language Models with Knowledge GraphsSource quoteL624: After brushing, the Dataset Overview statistics for the selected region showed that missing errors were the dominant error type, and that the model accuracy within this region was only 75.8%, lower than the 81.5% global accuracy. |
| 2026 | Qwen2.5-0.5B-Instruct (chain-of-thought) baseline | accuracy | 28.4 | cot · params=0.5B | Process Reward Agents for Steering Knowledge-Intensive ReasoningSource quoteL184: We evaluate whether PRA enables the drop-in replacement of frozen policy models without requiring any retraining. Table~\ref{tab:policy_reward_vertical} shows that PRA, despite being trained exclusively on reasoning traces from Qwen3-4B, generalizes well across a diverse set of policy models spanning both smaller and larger sizes. In several cases, models that perform poorly under standard decoding exhibit especially large relative improvements when paired with PRA, with the largest gains observed for smaller policy models. For example, on Qwen2.5-0.5B-Instruct, PRA improves MedQA accuracy from 28.4 to 54.1, corresponding to a 90.5% relative improvement over chain-of-thought. |
| 2026 | Qwen3-4B-Instruct baseline | Acc (%) | 74.00% | mode=vanilla · params=4B | Overalignment in Frontier LLMs: An Empirical Study of Sycophantic Behaviour in HealthcareSource quoteL129: Qwen3-4B-Instruct │ 74.00 │ 66.95 │ 0.21 │ 0.00 │ 0.19 │ 66.95 │ 0.21 │ 0.00 │ 0.19 |
| 2026 | Qwen3-4B-Thinking baseline | Acc (%) | 77.06% | mode=vanilla · params=4B | Overalignment in Frontier LLMs: An Empirical Study of Sycophantic Behaviour in HealthcareSource quoteL130: Qwen3-4B-Thinking │ 77.06 │ 65.91 │ 0.27 │ 0.00 │ 0.26 │ 65.91 │ 0.27 │ 0.00 │ 0.26 |
| 2026 | Med-PRM (BoM) baseline | accuracy | 71.43% | params=8B · setting=BoM · backbone=8B | MAPLE: Elevating Medical Reasoning from Statistical Consensus to Process-Led AlignmentSource quoteL145: Med-PRM (BoM) │ 8B │ 71.43 │ 63.00 │ 79.00 │ 78.70 |
| 2026 | Qwen3-8B-thinking baseline | accuracy | 75.80 | params=8B | From Chains to Graphs: Self-Structured Reasoning for General-Domain LLMsSource quoteL277: Qwen3-8B-thinking │ 80.40 │ 80.00 │ 75.80 |
| 2026 | Naive RAG (Qwen2.5-7B) baseline | ACC | 0.596 | split: test · 0-shot · params=7B · backbone=Qwen2.5-7B · retrieval=top-5 PubMed · sample-size=500 | BELIEF: Structured Evidence Modeling and Uncertainty-Aware Fusion for Biomedical Question AnsweringSource quoteL468: Naive RAG │ 0.488 │ 0.421 │ 0.596 │ 0.586 │ 0.519 │ 0.512 |
| 2026 | Official API (Gemini-2.5-flash) baseline | Accuracy | 83.82% | Gemini-2.5-flash on MedQA; official API baseline; accuracy averaged over three trials p… | Real Money, Fake Models: Deceptive Model Claims in Shadow APIsSource quoteL47: On high-risk medical benchmarks like MedQA, the accuracy of the Gemini-2.5-flash model drops precipitously, from 83.82% with the official API to approximately 37.00% across all examined shadow APIs. |
| 2026 | SFT baseline | Acc | 0.5981 | split: test · fine-tuned · params=4B · backbone=Qwen3-4B | Optimal Budgeted Adaptation of Large Language ModelsSource quoteL628: 0.5981 │ 0.5940 │ 0.0023 |
| 2025 | PANGEA (ours), Llama3.2-1B proposed | Accuracy | 44.62% | 0-shot · params=1B | PANGEA: Projection-Based Augmentation with Non-Relevant General Data for Enhanced Domain Adaptation in LLMsSource quoteL286: 44.62 |
| 2025 | Input-driven saliency pruning + fine-tuning (LLaMA 3 8B, 67% pruned) proposed | Accuracy | 20.59% | fine-tuned · params=8B · pruning=67% · backbone=LLaMA 3 8B | Enabling On-Device Medical AI Assistants via Input-Driven Saliency AdaptationSource quoteL170: LLaMA\,3\,8B │ 67% Pruned (FT) │ 5.58 │ 29.45% │ 20.59% │ 43.15% |
| 2025 | AutoMedPrompt with Llama 3 (70B) proposed non-standard slice | accuracy | 77.7% | split: test · params=70B | AutoMedPrompt: A New Framework for Optimizing LLM Medical Prompts Using Textual GradientsSource quoteL4: Large language models (LLMs) have demonstrated increasingly sophisticated performance in medical and other fields of knowledge. Traditional methods of creating specialist LLMs require extensive fine-tuning and training of models on large datasets. Recently, prompt engineering, instead of fine-tuning, has shown potential to boost the performance of general foundation models. However, prompting methods such as chain-of-thought (CoT) may not be suitable for all subspecialty, and k-shot approaches may introduce irrelevant tokens into the context space. We present AutoMedPrompt, which explores the use of textual gradients to elicit medically relevant reasoning through system prompt optimization. AutoMedPrompt leverages TextGrad's automatic differentiation via text to improve the ability of general foundation LLMs. We evaluated AutoMedPrompt on Llama 3, an open-source LLM, using several QA benchmarks, including MedQA, PubMedQA, and the nephrology subspecialty-specific NephSAP. Our results show that prompting with textual gradients outperforms previous methods on open-source LLMs and surpasses proprietary models such as GPT-4, Claude 3 Opus, and Med-PaLM 2. AutoMedPrompt sets a new state-of-the-art (SOTA) performance on PubMedQA with an accuracy of 82.6%, while also outperforming previous prompting strategies on open-sourced models for MedQA (77.7%) and NephSAP (63.8%). |
| 2025 | sudoLLM BFT (GPT-4o; fine-tuned on BQ) proposed | Alignment accuracy (Bob: unsafe queries refused) | 100% | 3-shot · epochs=1 · backbone=GPT-4o | sudoLLM: On Multi-role Alignment of Language ModelsSource quoteL238: 100 |
| 2025 | sudoLLM BFT (GPT-4o; fine-tuned on BQ) proposed | Alignment accuracy (Alice: queries answered) | 94.6% | 3-shot · epochs=1 · backbone=GPT-4o | sudoLLM: On Multi-role Alignment of Language ModelsSource quoteL241: 94.6 |
| 2025 | MedGemma 4B proposed | Accuracy | 64.4 | split: test · params=4B | MedGemma Technical ReportSource quoteL217: MedGemma 4B │ \checkmark │ 64.4 │ 55.7 │ 73.4 │ 59.3 │ 71.3 │ 70.8 │ 65.3 │ 83.0 │ 76.8 │ 53.0 │ 52.0 |
| 2025 | KAMAC proposed | Acc | 88.14 | MedQA comparison table; split and averaging are not specified in the cited lines. | A Knowledge-driven Adaptive Collaboration of LLMs for Enhancing Medical Decision-makingSource quoteL266: KAMAC │ 88.14 │ 88.30 │ 97.02 │ 88.11 │ 90.39 │ 1.28 │ 10.80 │ 2.55 │ 5.01 |
| 2025 | Instruction retrieval proposed | accuracy | 9.4% | 0-shot · params=3B–14B | Big Reasoning with Small Models: Instruction Retrieval at Inference TimeSource quoteL4: Can we bring big-scale reasoning to local-scale compute? Small language models (SLMs) are increasingly attractive for deployment because they run efficiently on local hardware, offering strong privacy, reduced cost, and lower environmental impact. Yet these models consistently struggle on tasks that require multi-step reasoning or specialized domain knowledge. To address this gap, we introduce instruction intervention at inference time. Our method builds an Instruction Corpus by grouping similar training questions and creating instructions that pair background knowledge with step-by-step procedures. At inference, the model retrieves the most relevant instructions and follows the steps. Unlike standard retrieval-augmented generation, which supplies raw passages, our approach provides structured scaffolds that guide reasoning. We evaluate this framework on MedQA (medical board exams), MMLU Professional Law, and MathQA using models from 3B to 14B parameters without any additional fine-tuning. Instruction retrieval yields consistent gains: 9.4% on MedQA, 7.9% on MMLU Law, and 5.1% on MathQA. Concise instructions outperform longer ones, and the magnitude of improvement depends strongly on model family and intrinsic reasoning ability. |
| 2025 | High School Concise instructions with a 9B model (family not specified) proposed | accuracy | +18pp | 0-shot · params=9B · instruction-variant=High School Concise | Big Reasoning with Small Models: Instruction Retrieval at Inference TimeSource quoteL89: Figure~\ref {fig:hs-concise-performance} shows the accuracy of the High School Concise instructions compared to zero-shot prompting across MathQA, MedQA, and MMLU Law. For the smallest models under 3B parameters, improvements are mixed and often negative. A few exceptions exist, such as Qwen-3 1.7B base, which gains +15pp on MedQA, but the same model shows negligible changes on MMLU and MathQA. This instability suggests that tiny models lack the intrinsic reasoning ability to reliably leverage retrieved scaffolds, which is in line with prior research \cite{li2025smallmodelsstrugglelearn}. At around 3B parameters, gains become consistently positive, even if modest. LLaMA-3 3B, for instance, improves by +1–5pp across benchmarks. This marks a capacity threshold: once a model is large enough to follow multi-step guidance, retrieved instructions shift from being noise to providing usable structure. Above this threshold, performance consistently improves. Models from 4B to 14B shows gains across all three tasks, with deltas typically in the +5–18pp range. The largest improvements appear in MedQA and MMLU Law, where domain-specific knowledge and reasoning may lack representation in the limited parameter space. For example, Gemma-2 9B improves by +14pp on MMLU Law and Mistral 7B by +16pp, while MedQA gains reach +18pp at 9B. In contrast, MathQA gains are more muted, though still positive, likely because mathematical reasoning is already well represented in pretraining data, leaving less headroom for improvement. Overall, retrieved instructions consistently boost accuracy once models exceed 3B parameters, with robust gains across both symbolic and domain-expert reasoning tasks. Notably, on MedQA and MMLU Law, the 14B parameter SLMs with retrieved instructions surpass the zero-shot accuracy of GPT-4o. |
| 2025 | AMG-RAG (PubMed-MKG-8B) proposed | Accuracy | 73.92% | params=8B · backbone-size=8B · configuration=PubMed-MKG | Agentic Medical Knowledge Graphs Enhance Medical Question Answering: Bridging the Gap Between LLMs and Evolving Medical KnowledgeSource quoteL254: \gls{myrag} │ PubMed-MKG-8B │ 73.92 |
| 2025 | AEPO-L (Ours), LLaMA-3.1 8B w/ AEPO proposed | Answer accuracy | 68.5 | params=8B · backbone=LLaMA-3.1 8B | What Makes Reasoning Invalid: Echo Reflection Mitigation for Large Language ModelsSource quoteL219: AEPO-L (Ours) │ 8B │ {68.5} |
| 2025 | AEPO-Q (Ours), Qwen2.5 7B w/ AEPO proposed | Answer accuracy | 62.5 | params=7B · backbone=Qwen2.5 7B | What Makes Reasoning Invalid: Echo Reflection Mitigation for Large Language ModelsSource quoteL220: AEPO-Q (Ours) │ 7B │ {62.5} |
| 2025 | HuatuoGPT-O1-8B w/ AEPO proposed | Answer accuracy | 75.4 | fine-tuned · params=8B · backbone=HuatuoGPT-O1-8B | What Makes Reasoning Invalid: Echo Reflection Mitigation for Large Language ModelsSource quoteL286: w/ AEPO (Ours) │ 75.4 │ 63.9 |
| 2025 | KAG-Med-Thinker proposed | Accuracy | 85.28 | params=14B · backbone=DeepSeek-R1-Distill-Qwen-14B | KAG-Thinker: Interactive Thinking and Deep Reasoning in LLMs via Knowledge-Augmented GenerationSource quoteL422: KAG-Med-Thinker │ 85.28 |
| 2025 | Clinical-R1-3B (Cold Start + CRPO) proposed | Accuracy | 53.07% | method=Cold Start + CRPO · params=3B | Clinical-R1: Empowering Large Language Models for Faithful and Comprehensive Reasoning with Clinical Objective Relative Policy OptimizationSource quoteL196: \begin{tabular}[c]{@{}l@{}}w/ Cold Start + CRPO (Clinical-R1-3B) │ \bf 3.29 │ \bf 2.33 │ \bf 4.95 │ \bf 2.02 │ \bf 12.95 │ \bf5.76 │ \bf3.36 │ 0.76 │ \bf 53.07 |
| 2025 | MDTeamGPT proposed | Accuracy | 90.1% | base-model=GPT-4 Turbo · consultation-rounds=600 | MDTeamGPT: A Self-Evolving LLM-based Multi-Agent Framework for Multi-Disciplinary Team Medical ConsultationSource quoteL30: \item Experimental results demonstrate that the framework, utilizing 600 rounds of consultation experience, achieves accuracies of 90.1% on the MedQA dataset and 83.9% on the PubMedQA dataset. Cross-dataset tests further confirm that the knowledge bases retain generalizable reasoning skills, not just isolated consultation data. |
| 2025 | Med-swallow-13b fine-tuned with the mix setting (J-Casemap and MedQA data) proposed | Accuracy | 37.0 | fine-tuned · model=Med-swallow-13b · params=13b · training-data=J-Casemap and MedQA | Causal Tree Extraction from Medical Case Reports: A Novel Task for Experts-like Text ComprehensionSource quoteL313: + mix │ 37.0 │ 34.1 │ 38.6 |
| 2025 | TAGS with GPT-4o proposed non-standard slice | accuracy | 31.8% | backbone=GPT-4o · parameter-updates=none | TAGS: A Test-Time Generalist-Specialist Framework with Retrieval-Augmented Reasoning and VerificationSource quoteL30: Extensive experiments across nine MedQA benchmarks validate the robustness and adaptability of TAGS under both non-fine-tuned and fine-tuned settings. Our method consistently outperforms strong prompting and agent-based baselines across multiple foundation models, including GPT-4o (18.0% to 31.8%), DeepSeek-R1 (27.2% to 44.0%), and Qwen-2.5-7B (14.1% to 23.9%). Notably, we show that even without retrieving semantically similar exemplars, TAGS maintains strong performance by exposing models to diverse reasoning patterns rather than specific answers. |
| 2025 | TAGS with DeepSeek-R1 proposed non-standard slice | accuracy | 44.0% | backbone=DeepSeek-R1 · parameter-updates=none | TAGS: A Test-Time Generalist-Specialist Framework with Retrieval-Augmented Reasoning and VerificationSource quoteL30: Extensive experiments across nine MedQA benchmarks validate the robustness and adaptability of TAGS under both non-fine-tuned and fine-tuned settings. Our method consistently outperforms strong prompting and agent-based baselines across multiple foundation models, including GPT-4o (18.0% to 31.8%), DeepSeek-R1 (27.2% to 44.0%), and Qwen-2.5-7B (14.1% to 23.9%). Notably, we show that even without retrieving semantically similar exemplars, TAGS maintains strong performance by exposing models to diverse reasoning patterns rather than specific answers. |
| 2025 | TAGS with Qwen2.5-7B proposed non-standard slice | average accuracy | 23.9% | 0-shot · params=7B · backbone=Qwen2.5-7B · parameter-updates=none | TAGS: A Test-Time Generalist-Specialist Framework with Retrieval-Augmented Reasoning and VerificationSource quoteL250: To further contextualize the performance of our TAGS framework, we evaluate its effectiveness when integrated with the Qwen2.5-7B base model and compare its performance against a series of prominent open-source and medically fine-tuned large language models across the same nine challenging MedQA datasets. The results of this comparison are presented in Table~\ref{tab:results_medllm}. As shown in the table, our TAGS framework substantially boosts the zero-shot question answering capability of the base Qwen2.5-7B model, improving its average accuracy from 14.1% to 23.9%. |
| 2025 | QAP (Flan-T5 (11B)) proposed | accuracy | 44.01 | params=11B · backbone=Flan-T5-11B · knowledge-graph=UMLS | Question-Aware Knowledge Graph Prompting for Enhancing Large Language ModelsSource quoteL267: {44.01} |
| 2025 | Llama3.1 models fine-tuned on English-majority data proposed | accuracy | 29.8 | fine-tuned | Bridging language barriers in healthcare: a study on Arabic LLMsSource quoteL185: Our results in Table~\ref{tab:combined-results} show that different ratio of Arabic-English data yield to different performance levels depending on the evaluation task. For PubMedQA, training with exclusively Arabic data produces the best accuracy (71.2). While for MedMCQA and MedQA, the models perform best with strong Arabic majority and English Majority, respectively (35.1 and 29.8). Surprisingly, for the MMLU datasets, which focuses on testing direct knowledge application, using only English data, achieves 42.4 compared to the 39.8 zero-shot accuracy. |
| 2025 | Qwen2.5-32B-Instruct, Resident role ablation | accuracy drop | 0.051 | split: test · role=Resident · params=32B · backbone=Qwen2.5-32B-Instruct · decoding=greedy · neuron-masking=top 5% in top 4 hidden layers | Dissecting Role Cognition in Medical LLMs via Neuronal AblationSource quoteL206: As shown in Figures \ref{fig:RoleAccDrop}.A-F , the accuracy drop after masking was consistent across all roles. For example, in the Qwen2.5-32B-Instruct model on the MedQA dataset, the accuracy drops for the roles of "Resident," "Medical Student," and "China Doctor" were 0.051, 0.060, and 0.046, respectively. The maximum difference in accuracy drop was only 1.4%, and the same pattern was observed across different datasets (MedQA, MedMCQA, MMLU-Med). We also conducted McNemar's test and observed no significant differences in accuracy drops between roles (p > 0.05). This indicates that the impact of neuron ablation on performance was consistent across different roles. |
| 2025 | Qwen2.5-32B-Instruct, Medical Student role ablation | accuracy drop | 0.060 | split: test · role=Medical Student · params=32B · backbone=Qwen2.5-32B-Instruct · decoding=greedy · neuron-masking=top 5% in top 4 hidden layers | Dissecting Role Cognition in Medical LLMs via Neuronal AblationSource quoteL206: As shown in Figures \ref{fig:RoleAccDrop}.A-F , the accuracy drop after masking was consistent across all roles. For example, in the Qwen2.5-32B-Instruct model on the MedQA dataset, the accuracy drops for the roles of "Resident," "Medical Student," and "China Doctor" were 0.051, 0.060, and 0.046, respectively. The maximum difference in accuracy drop was only 1.4%, and the same pattern was observed across different datasets (MedQA, MedMCQA, MMLU-Med). We also conducted McNemar's test and observed no significant differences in accuracy drops between roles (p > 0.05). This indicates that the impact of neuron ablation on performance was consistent across different roles. |
| 2025 | Qwen2.5-32B-Instruct, China Doctor role ablation | accuracy drop | 0.046 | split: test · role=China Doctor · params=32B · backbone=Qwen2.5-32B-Instruct · decoding=greedy · neuron-masking=top 5% in top 4 hidden layers | Dissecting Role Cognition in Medical LLMs via Neuronal AblationSource quoteL206: As shown in Figures \ref{fig:RoleAccDrop}.A-F , the accuracy drop after masking was consistent across all roles. For example, in the Qwen2.5-32B-Instruct model on the MedQA dataset, the accuracy drops for the roles of "Resident," "Medical Student," and "China Doctor" were 0.051, 0.060, and 0.046, respectively. The maximum difference in accuracy drop was only 1.4%, and the same pattern was observed across different datasets (MedQA, MedMCQA, MMLU-Med). We also conducted McNemar's test and observed no significant differences in accuracy drops between roles (p > 0.05). This indicates that the impact of neuron ablation on performance was consistent across different roles. |
| 2025 | + Case(70B) ablation | Accuracy | 75.0% | 0-shot · runs=3 · params=70B · subset=300 randomly selected samples · case-model=70B | LLM-MedQA: Enhancing Medical Question Answering through Case Studies in Large Language ModelsSource quoteL321: + Case(70B) │ 75.0 (\uparrow 2.0) │ 74.9(\uparrow 1.4) │ 74.7(\uparrow 1.8) │ 74.8(\uparrow 1.8) |
| 2025 | AMG-RAG without search functionality ablation | accuracy | 67.16% | removed-component=search functionality | Agentic Medical Knowledge Graphs Enhance Medical Question Answering: Bridging the Gap Between LLMs and Evolving Medical KnowledgeSource quoteL247: Table~\ref{tab:medqa_results} presents a comprehensive comparison of various RAG models evaluated on the MEDQA benchmark. This includes models with different retrieval mechanisms and model sizes, enabling a head-to-head evaluation of \gls{myrag} with other state-of-the-art baselines such as Self-RAG \citep{asai2023self}, HyDE \citep{gao2022precise}, GraphRAG \citep{edge2024local}, and MedRAG \citep{zhao2025medrag}. The results clearly show that \gls{myrag} configured with the PubMed-\gls{mkg} and an 8B LLM backbone achieves the highest accuracy of 73.92%, surpassing all competing models. Notably, ablation results indicate that removing search functionality or CoT reasoning significantly degrades accuracy (dropping to 67.16% and 66.69%, respectively), confirming the essential role of structured retrieval and reasoning components in complex question answering. Other baseline models such as Gemini-pro and PMC-LLaMA demonstrate weaker performance, further validating the efficacy of domain-aware retrieval and reasoning modules proposed in \gls{myrag}. Importantly, the domain specificity and freshness of PubMedSearch provide a significant advantage in retrieving relevant knowledge that general-purpose search modules often fail to deliver. |
| 2025 | AMG-RAG without CoT reasoning ablation | accuracy | 66.69% | cot · removed-component=chain-of-thought reasoning | Agentic Medical Knowledge Graphs Enhance Medical Question Answering: Bridging the Gap Between LLMs and Evolving Medical KnowledgeSource quoteL247: Table~\ref{tab:medqa_results} presents a comprehensive comparison of various RAG models evaluated on the MEDQA benchmark. This includes models with different retrieval mechanisms and model sizes, enabling a head-to-head evaluation of \gls{myrag} with other state-of-the-art baselines such as Self-RAG \citep{asai2023self}, HyDE \citep{gao2022precise}, GraphRAG \citep{edge2024local}, and MedRAG \citep{zhao2025medrag}. The results clearly show that \gls{myrag} configured with the PubMed-\gls{mkg} and an 8B LLM backbone achieves the highest accuracy of 73.92%, surpassing all competing models. Notably, ablation results indicate that removing search functionality or CoT reasoning significantly degrades accuracy (dropping to 67.16% and 66.69%, respectively), confirming the essential role of structured retrieval and reasoning components in complex question answering. Other baseline models such as Gemini-pro and PMC-LLaMA demonstrate weaker performance, further validating the efficacy of domain-aware retrieval and reasoning modules proposed in \gls{myrag}. Importantly, the domain specificity and freshness of PubMedSearch provide a significant advantage in retrieving relevant knowledge that general-purpose search modules often fail to deliver. |
| 2025 | QAP w/o Q (Flan-T5 (11B)) ablation | accuracy | 42.26 | params=11B · backbone=Flan-T5-11B · knowledge-graph=UMLS · removed-component=QNA | Question-Aware Knowledge Graph Prompting for Enhancing Large Language ModelsSource quoteL282: 42.26 |
| 2025 | No-evidence baseline (w/o; Qwen-2.5-1.5B) ablation | Accuracy | 35.08% | params=1.5B | META-RAG: Meta-Analysis-Inspired Evidence-Re-Ranking Method for Retrieval-Augmented Generation in Evidence-Based MedicineSource quoteL236: w/o │ 35.08 |
| 2025 | No-evidence baseline (w/o; Qwen-2.5-32B) ablation | Accuracy | 62.06% | params=32B | META-RAG: Meta-Analysis-Inspired Evidence-Re-Ranking Method for Retrieval-Augmented Generation in Evidence-Based MedicineSource quoteL248: w/o │ 62.06 |
| 2025 | Gemma 3 4B | Accuracy | 50.7 | split: test · params=4B | MedGemma Technical ReportSource quoteL218: Gemma 3 4B │ \checkmark │ 50.7 │ 45.4 │ 68.4 │ 54.1 │ 69.8 │ 77.8 │ 63.0 │ 74.0 │ 65.4 │ 42.8 │ 48.0 |
| 2025 | JSL MedLlama | accuracy on MedQA | 0.61 | Table 1 predictive-validity experiment; the study used the complete Step 1 and Step 2 M… | Position: Medical Large Language Model Benchmarks Should Prioritize Construct ValiditySource quoteL149: JSL MedLlama │ \multicolumn{1}{c|}{0.61} │ 0.37 │ 0.49 |
| 2025 | PMY MedLLama | accuracy on MedQA | 0.75 | Table 1 predictive-validity experiment; the study used the complete Step 1 and Step 2 M… | Position: Medical Large Language Model Benchmarks Should Prioritize Construct ValiditySource quoteL150: PMY MedLLama │ \multicolumn{1}{c|}{0.75} │ 0.36 │ 0.45 } |
| 2025 | EMRC baseline | ACC | 83.42% | Dataset-level accuracy, reported in the MedQA Acc. column. | Expertise-aware Multi-LLM Recruitment and Collaboration for Medical Decision-MakingSource quoteL271: Our │ 66.67 │ 77.78 │ 58.99 │ 74.75 │ 82.00 │ 71.91 │ 83.42 |
| 2025 | BioMistral 7B baseline | LLM-Accuracy | 0.74 | split: test · params=7B · backbone=LLaMA-3 · evaluator=LLaMA-3 | Med-CoDE: Medical Critique based Disagreement Evaluation FrameworkSource quoteL101: MEDQA USMLE │ 0.14 │ 0.07 │ 0.74 │ 0.44 │ 0.29 │ 0.16 │ 0.11 |
| 2025 | Mistral 7B v2.0 baseline | LLM-Accuracy | 0.68 | split: test · params=7B · backbone=LLaMA-3 · evaluator=LLaMA-3 | Med-CoDE: Medical Critique based Disagreement Evaluation FrameworkSource quoteL107: MEDQA USMLE │ 0.16 │ 0.12 │ 0.68 │ 0.47 │ 0.28 │ 0.15 │ 0.01 |
| 2025 | Claude Sonnet 4 baseline | Accuracy | 91.2% | multi-turn | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL4: Large language models (LLMs) are rapidly transitioning into medical clinical use, yet their reliability under realistic, multi-turn interactions remains poorly understood. Existing evaluation frameworks typically assess single-turn question answering under idealized conditions, overlooking the complexities of medical consultations where conflicting input, misleading context, and authority influence are common. We introduce MedQA-Followup, a framework for systematically evaluating multi-turn robustness in medical question answering. Our approach distinguishes between shallow robustness (resisting misleading initial context) and deep robustness (maintaining accuracy when answers are challenged across turns), while also introducing an indirect–direct axis that separates contextual framing (indirect) from explicit suggestion (direct). Using controlled interventions on the MedQA dataset, we evaluate five state-of-the-art LLMs and find that while models perform reasonably well under shallow perturbations, they exhibit severe vulnerabilities in multi-turn settings, with accuracy dropping from 91.2% to as low as 13.5% for Claude Sonnet 4. Counterintuitively, indirect, context-based interventions are often more harmful than direct suggestions, yielding larger accuracy drops across models and exposing a significant vulnerability for clinical deployment. Further compounding analyses reveal model differences, with some showing further performance drops under repeated interventions while others partially recovering or even improving. These findings highlight multi-turn robustness as a critical but underexplored dimension for safe and reliable deployment of medical LLMs. Dataset and code available on |
| 2025 | Claude Sonnet 4 baseline | Accuracy | 13.5% | multi-turn | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL4: Large language models (LLMs) are rapidly transitioning into medical clinical use, yet their reliability under realistic, multi-turn interactions remains poorly understood. Existing evaluation frameworks typically assess single-turn question answering under idealized conditions, overlooking the complexities of medical consultations where conflicting input, misleading context, and authority influence are common. We introduce MedQA-Followup, a framework for systematically evaluating multi-turn robustness in medical question answering. Our approach distinguishes between shallow robustness (resisting misleading initial context) and deep robustness (maintaining accuracy when answers are challenged across turns), while also introducing an indirect–direct axis that separates contextual framing (indirect) from explicit suggestion (direct). Using controlled interventions on the MedQA dataset, we evaluate five state-of-the-art LLMs and find that while models perform reasonably well under shallow perturbations, they exhibit severe vulnerabilities in multi-turn settings, with accuracy dropping from 91.2% to as low as 13.5% for Claude Sonnet 4. Counterintuitively, indirect, context-based interventions are often more harmful than direct suggestions, yielding larger accuracy drops across models and exposing a significant vulnerability for clinical deployment. Further compounding analyses reveal model differences, with some showing further performance drops under repeated interventions while others partially recovering or even improving. These findings highlight multi-turn robustness as a critical but underexplored dimension for safe and reliable deployment of medical LLMs. Dataset and code available on |
| 2025 | GPT-4.1 baseline | Accuracy | 88.2 | multi-turn · intervention=direct-inc_letter · system_prompt=none | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL397: \textbf{\texttt{inc\_letter} (avg)} │ 42.9 (-53.3%) │ 88.2 (-5.0%) │ 85.2 (-6.4%) │ 54.2 (-15.5%) │ 69.1 (-18.3%) |
| 2025 | GPT-4.1 baseline | Accuracy | 58.0 | multi-turn · intervention=indirect-context · system_prompt=none | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL403: \textbf{\texttt{context} (avg)} │ 45.6 (-50.3%) │ 58.0 (-37.5%) │ 55.8 (-38.7%) │ 40.0 (-37.6%) │ 56.9 (-32.8%) |
| 2025 | GPT-4.1 mini baseline | Accuracy | 85.2 | multi-turn · intervention=direct-inc_letter · system_prompt=none | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL397: \textbf{\texttt{inc\_letter} (avg)} │ 42.9 (-53.3%) │ 88.2 (-5.0%) │ 85.2 (-6.4%) │ 54.2 (-15.5%) │ 69.1 (-18.3%) |
| 2025 | GPT-4.1 mini baseline | Accuracy | 55.8 | multi-turn · intervention=indirect-context · system_prompt=none | Shallow Robustness, Deep Vulnerabilities: Multi-Turn Evaluation of Medical LLMsSource quoteL403: \textbf{\texttt{context} (avg)} │ 45.6 (-50.3%) │ 58.0 (-37.5%) │ 55.8 (-38.7%) │ 40.0 (-37.6%) │ 56.9 (-32.8%) |
| 2025 | Vanilla fine-tuning (VFT; GPT-4o; fine-tuned on OQ) baseline | Alignment accuracy (Bob: unsafe queries refused) | 1.0% | 3-shot · epochs=1 · backbone=GPT-4o | sudoLLM: On Multi-role Alignment of Language ModelsSource quoteL237: 1.0 |
| 2025 | Vanilla fine-tuning (VFT; GPT-4o; fine-tuned on OQ) baseline | Alignment accuracy (Alice: queries answered) | 100% | 3-shot · epochs=1 · backbone=GPT-4o | sudoLLM: On Multi-role Alignment of Language ModelsSource quoteL240: 100 |
| 2025 | Med-PaLM baseline | Acc | 67.2 | evaluation=Auto+Human | Reviewing clinical knowledge in medical large language modelsSource quoteL935: Med-PaLM │ Auto+Human │ 67.2// \mid |
| 2025 | Med-PaLM 2 (Ensemble Refinement) baseline | Acc | 85.4 | variant=Ensemble Refinement · evaluation=Auto+Human | Reviewing clinical knowledge in medical large language modelsSource quoteL936: Med-PaLM 2(Ensemble Refinement) │ Auto+Human │ 85.4// \mid │ 72.3 |
| 2025 | Med-PaLM 2 baseline | Acc | 86.5 | evaluation=Auto+Human | Reviewing clinical knowledge in medical large language modelsSource quoteL937: Med-PaLM 2 │ Auto+Human │ 86.5// \mid │ 72.3 |
| 2025 | SOTA fine-tuning approach baseline | accuracy | 0.4195 | approach=SOTA | Benchmarking large language models for biomedical natural language processing applications and recommendationsSource quoteL80: MedQA, the SOTA approach had an accuracy of 0.4195. GPT-4 under the zero-shot setting had almost |
| 2025 | MDAgent baseline | Acc | 87.74 | MedQA comparison table; split and averaging are not specified in the cited lines. | A Knowledge-driven Adaptive Collaboration of LLMs for Enhancing Medical Decision-makingSource quoteL265: MDAgent │ 87.74 │ 87.92 │ 96.92 │ 87.55 │ 90.03 │ 2.41 │ 15.62 │ 3.34 │ 6.31 |
| 2025 | LLaMA-3.1 8B + DAPO baseline | Answer accuracy | 62.9 | params=8B · backbone=LLaMA-3.1 8B | What Makes Reasoning Invalid: Echo Reflection Mitigation for Large Language ModelsSource quoteL214: LLaMA-3.1 + DAPO │ 8B │ {62.9} |
| 2025 | Qwen2.5 7B + DAPO baseline | Answer accuracy | 57.1 | params=7B · backbone=Qwen2.5 7B | What Makes Reasoning Invalid: Echo Reflection Mitigation for Large Language ModelsSource quoteL218: Qwen2.5 + DAPO │ 7B │ {57.1} |
| 2025 | IRCoT baseline | Accuracy | 81.33 | params=14B · backbone=DeepSeek-R1-Distill-Qwen-14B | KAG-Thinker: Interactive Thinking and Deep Reasoning in LLMs via Knowledge-Augmented GenerationSource quoteL420: IRCoT~\cite{DBLP:conf/acl/TrivediBKS23} │ 81.33 |
| 2025 | ReAct baseline | Accuracy | 80.87 | params=14B · backbone=DeepSeek-R1-Distill-Qwen-14B | KAG-Thinker: Interactive Thinking and Deep Reasoning in LLMs via Knowledge-Augmented GenerationSource quoteL421: ReAct~\cite{DBLP:conf/iclr/YaoZYDSN023} │ 80.87 |
| 2025 | Naive RAG+adaptive baseline | Accuracy | 81.48 | params=14B · backbone=DeepSeek-R1-Distill-Qwen-14B | KAG-Thinker: Interactive Thinking and Deep Reasoning in LLMs via Knowledge-Augmented GenerationSource quoteL419: Naive RAG+adaptive~\cite{DBLP:conf/naacl/JeongBCHP24} │ 81.48 |
| 2025 | Naive RAG baseline | Accuracy | 79.00 | MedQA accuracy result; the table excerpt does not identify the base-model variant for t… | KAG-Thinker: Interactive Thinking and Deep Reasoning in LLMs via Knowledge-Augmented GenerationSource quoteL418: Naive RAG~\cite{DBLP:conf/nips/LewisPPPKGKLYR020} │ 79.00 |
| 2025 | GRPO (Qwen3-4B) baseline | accuracy | 76.12% | fine-tuned · params=4B · backbone=Qwen3-4B · distribution=in-distribution | Exploiting Tree Structure for Credit Assignment in RL Training of LLMsSource quoteL231: \quad + GRPO │ 87.6 │ 59.81 │ 85.0 │ 76.12 │ 60.55 │ 83.19 |
| 2025 | GPT-4 baseline | Accuracy | 74.16% | 0-shot · answer-options=5 | Benchmarking Large Language Models on Answering and Explaining Challenging Medical QuestionsSource quoteL242: 74.16 |
| 2025 | GPT-4o baseline baseline non-standard slice | accuracy | 18.0% | backbone=GPT-4o | TAGS: A Test-Time Generalist-Specialist Framework with Retrieval-Augmented Reasoning and VerificationSource quoteL30: Extensive experiments across nine MedQA benchmarks validate the robustness and adaptability of TAGS under both non-fine-tuned and fine-tuned settings. Our method consistently outperforms strong prompting and agent-based baselines across multiple foundation models, including GPT-4o (18.0% to 31.8%), DeepSeek-R1 (27.2% to 44.0%), and Qwen-2.5-7B (14.1% to 23.9%). Notably, we show that even without retrieving semantically similar exemplars, TAGS maintains strong performance by exposing models to diverse reasoning patterns rather than specific answers. |
| 2025 | DeepSeek-R1 baseline baseline non-standard slice | accuracy | 27.2% | backbone=DeepSeek-R1 | TAGS: A Test-Time Generalist-Specialist Framework with Retrieval-Augmented Reasoning and VerificationSource quoteL30: Extensive experiments across nine MedQA benchmarks validate the robustness and adaptability of TAGS under both non-fine-tuned and fine-tuned settings. Our method consistently outperforms strong prompting and agent-based baselines across multiple foundation models, including GPT-4o (18.0% to 31.8%), DeepSeek-R1 (27.2% to 44.0%), and Qwen-2.5-7B (14.1% to 23.9%). Notably, we show that even without retrieving semantically similar exemplars, TAGS maintains strong performance by exposing models to diverse reasoning patterns rather than specific answers. |
| 2025 | Qwen2.5-7B baseline baseline non-standard slice | average accuracy | 14.1% | 0-shot · params=7B · backbone=Qwen2.5-7B | TAGS: A Test-Time Generalist-Specialist Framework with Retrieval-Augmented Reasoning and VerificationSource quoteL250: To further contextualize the performance of our TAGS framework, we evaluate its effectiveness when integrated with the Qwen2.5-7B base model and compare its performance against a series of prominent open-source and medically fine-tuned large language models across the same nine challenging MedQA datasets. The results of this comparison are presented in Table~\ref{tab:results_medllm}. As shown in the table, our TAGS framework substantially boosts the zero-shot question answering capability of the base Qwen2.5-7B model, improving its average accuracy from 14.1% to 23.9%. |
| 2025 | OpenMedLM (Yi-34B) baseline | accuracy | 72.6% | fine-tuned · params=34B · backbone=Yi-34B · fine-tuning=none | Reasoning LLMs in the Medical Domain: A Literature SurveySource quoteL120: The OpenMedLM study demonstrated that sophisticated prompt engineering can match or exceed extensive fine-tuning for medical question-answering tasks when using powerful open-source LLMs \cite{maharjan2024openmedlm} \cite{berger2024tackling}. This finding has significant implications for healthcare AI accessibility, as specialized medical model fine-tuning typically requires substantial computational resources and curated datasets. Using the Yi-34B foundation model, researchers systematically evaluated various prompting strategies, including zero-shot, few-shot, chain-of-thought, and ensemble methods like self-consistency voting. Their approach established new state-of-the-art performance on multiple medical benchmarks, surpassing previously fine-tuned open-source models. OpenMedLM achieved 72.6% accuracy on MedQA (a 2.4% improvement over previous open-source SOTA) and 81.7% accuracy on the MMLU medical subset \cite{maharjan2024openmedlm}. These results highlight how meticulous prompt design can effectively elicit latent medical reasoning capabilities from generalist models without domain-specific fine-tuning. |
| 2024 | MedAgent-Zero proposed | Accuracy | 92.22 | backbone=GPT-4o · training-data=MedQA labeled training data not used | Agent Hospital: A Simulacrum of Hospital with Evolvable Medical AgentsSource quoteL292: MedAgent-Zero │ {\ul 74.31} │ {\ul 89.71} │ {\ul 92.22} │ 96.15 |
| 2024 | MedAgent-Zero (Hybrid) proposed | Accuracy | 92.77 | backbone=GPT-4o · training-data=MedQA training data added to medical case base | Agent Hospital: A Simulacrum of Hospital with Evolvable Medical AgentsSource quoteL293: MedAgent-Zero (Hybrid) │ 76.83 │ 91.20 │ 92.77 │ 96.15 |
| 2024 | MedGraphRAG (GPT-4) proposed | Accuracy | 91.3% | model=GPT-4 · retrieval=MedGraphRAG | Medical Graph RAG: Towards Safe Medical Large Language Model via Graph Retrieval-Augmented GenerationSource quoteL164: GPT-4 │ 86.5 │ 83.4 │ 91.3 │ 81.5 │ 83.3 │ 91.5 │ 98.1 │ 95.8 │ 93.2 │ 98.5 │ 96.4 |
| 2024 | LTM-enhanced MedAgent-Zero (LTM-rewritten experiences) proposed non-standard slice | accuracy | 95.83% | few-shot · subset=respiratory · repetitions=3 · interactions=40000 | Long Term Memory: The Foundation of AI Self-EvolutionSource quoteL630: LTM-enhanced │ 91.67 │ 94.44 │ 91.67 │ 93.06 │ 93.06 │ 91.67 │ 93.06 │ 95.83 │ 94.44 │ 93.06 |
| 2024 | MedGENIE-FID-Flan-T5 proposed | Accuracy | 53.1% | fine-tuned · reader=Fusion-in-Decoder · backbone=Flan-T5 | To Generate or to Retrieve? On the Effectiveness of Artificial Contexts for Medical Open-Domain Question AnsweringSource quoteL779: MedGENIE-FID-Flan-T5 │ G (PMC-LLaMA) │ Fine-tuned │ 250M │ 53.1 |
| 2024 | MedGENIE-Phi-3-mini proposed | Accuracy | 64.7 | 1-shot · params=3.8B · backbone=Phi-3-mini | To Generate or to Retrieve? On the Effectiveness of Artificial Contexts for Medical Open-Domain Question AnsweringSource quoteL776: \multirow{15}{*}{} │ MedGENIE-Phi-3-mini │ G ({PMC-LLaMA}) │ 1-shot │ 3.8B │ 64.7 |
| 2024 | RAG² balanced retrieval (retrieval-component-only comparison) proposed | Accuracy | 55.3 | params=8B · backbone=Llama-3-8B-Instruct · comparison=retrieval-component-only · retrieval-top-k=1 | Rationale-Guided Retrieval Augmented Generation for Medical Question AnsweringSource quoteL316: + Ours │ 55.3 │ 51.3 │ 65.8 |
| 2024 | Qwen2-0.5B-RLEF proposed non-standard slice | Tglu accuracy | 0.289 | fine-tuned · params=0.5B · subset=diabetes-related (194 questions) · training-steps=11520 | Best of Both Worlds: Harmonizing LLM Capabilities in Decision-Making and Question-Answering for Treatment RegimesSource quoteL335: 0.289 |
| 2024 | Coke proposed | Accuracy | 0.778 | Full Coke model; benchmark-level accuracy on MedQA-USMLE. | Cost-efficient Knowledge-based Question Answering with Large Language ModelsSource quoteL237: 0.778 |
| 2024 | OpenMedLM, Yi 34B (kNN few-shot CoT with shuffled-option ensemble/self-consistency) proposed non-standard slice | Benchmark Accuracy | 72.6% | split: test · few-shot · model=Yi 34B · params=34B · ensemble=5 shuffled-option runs · prompting=kNN-selected few-shot CoT | OpenMedLM: Prompt engineering can out-perform fine-tuning in medical question-answering with open-source large language modelsSource quoteL194: 72.6% for the Yi 34B foundation model. |
| 2024 | Medprompt baseline | Accuracy | 91.52 | backbone=GPT-4o | Agent Hospital: A Simulacrum of Hospital with Evolvable Medical AgentsSource quoteL291: Medprompt │ 73.76 │ 89.47 │ 91.52 │ {\ul 95.36} |
| 2024 | Mistral 7B baseline | Accuracy | 63.0% | fine-tuned · params=7B · backbone=Mistral 7B | Assessing The Potential Of Mid-Sized Language Models For Clinical QASource quoteL4: Large language models, such as GPT-4 and Med-PaLM, have shown impressive performance on clinical tasks; however, they require access to compute, are closed-source, and cannot be deployed on device. Mid-size models such as BioGPT-large, BioMedLM, LLaMA 2, and Mistral 7B avoid these drawbacks, but their capacity for clinical tasks has been understudied. To help assess their potential for clinical use and help researchers decide which model they should use, we compare their performance on two clinical question-answering (QA) tasks: MedQA and consumer query answering. We find that Mistral 7B is the best performing model, winning on all benchmarks and outperforming models trained specifically for the biomedical domain. While Mistral 7B’s MedQA score of 63.0% approaches the original Med-PaLM, and it often can produce plausible responses to consumer health queries, room for improvement still exists. This study provides the first head-to-head assessment of open source mid-sized models on clinical tasks. |
| 2024 | GraphRAG (GPT-4) baseline | Accuracy | 88.9% | model=GPT-4 · retrieval=GraphRAG | Medical Graph RAG: Towards Safe Medical Large Language Model via Graph Retrieval-Augmented GenerationSource quoteL157: GPT-4 │ 78.4 │ 77.8 │ 88.9 │ 77.2 │ 77.9 │ 82.1 │ 95.1 │ 94.8 │ 82.6 │ 92.5 │ 94.0 |
| 2024 | Med-PaLM2 baseline | accuracy | 85% | USMLE-style questions; the split is not specified in the review. | Developing ChatGPT for biology and medicine: a complete review of biomedical question answeringSource quoteL328: The recent introduction of two models, Med-PaLM2 (Singhal et al, 2023) and PMC-LLaMA (Wu et al, 2023), has significantly reshaped the field of medical question answering, enabling the generation of high-quality responses. Med-PaLM2, a large language model, harnesses the power of Google’s large language models to provide high-quality answers to medical questions. It achieved an impressive 86.5% accuracy and was the first language model to perform at an “expert” test-taker level on the MedQA dataset of USMLE-style questions, reaching 85% accuracy. |
| 2024 | Flan-PaLM baseline | accuracy | 67.6% | Medical question-answering evaluation on a multiple-choice dataset. | A Comprehensive Survey on Evaluating Large Language Model Applications in the Medical IndustrySource quoteL104: \cite{singhal2023large} evaluates the Pathways Language Model (PaLM) and its instruction-tuned variant, Flan-PaLM, across multiple medical question-answering tasks. The clinical tasks assessed include professional medicine, medical research, and consumer medical queries, encompassing areas like diagnostic reasoning and clinical knowledge application. Evaluation metrics spanned factuality, comprehension, reasoning, potential harm, and bias, alongside accuracy on multiple-choice datasets such as MedQA, MedMCQA, PubMedQA, and MMLU clinical topics. Flan-PaLM achieved state-of-the-art accuracy, notably 67.6% on MedQA, surpassing previous benchmarks by over 17%. Human evaluations, however, highlighted areas for improvement, particularly in aligning model responses with clinical expertise and minimizing potential misinformation or harm. |
| 2024 | Mistral-Large-3-675B baseline | Accuracy | 84.00% | params=675B | MEDIC: Comprehensive Evaluation of Leading Indicators for LLM Safety and Utility in Clinical ApplicationsSource quoteL175: Mistral-Large-3-675B │ 84.00 │ 77.00 │ 54.15 │ 48.59 |
| 2024 | Codex baseline | Accuracy | 52.5 | 0-shot · params=175B | To Generate or to Retrieve? On the Effectiveness of Artificial Contexts for Medical Open-Domain Question AnsweringSource quoteL744: Codex\tnote{1} │ \varnothing │ 0-zhot │ 175B │ 52.5 |
| 2024 | MedRAG baseline | Accuracy | 51.9 | params=8B · backbone=Llama-3-8B-Instruct · comparison=retrieval-component-only · retrieval-top-k=1 | Rationale-Guided Retrieval Augmented Generation for Medical Question AnsweringSource quoteL315: + MedRAG │ {51.9} │ {49.0} │ {65.1} |
| 2024 | Qwen2-1.5B baseline non-standard slice | Tglu accuracy | 0.299 | params=1.5B · subset=diabetes-related (194 questions) | Best of Both Worlds: Harmonizing LLM Capabilities in Decision-Making and Question-Answering for Treatment RegimesSource quoteL337: 0.299 |
| 2024 | Med-PaLM 2 baseline | Acc(%) | 85.4% | Fundamental Capabilities of Large Language Models and their Applications in Domain Scenarios: A SurveySource quoteL347: 85.4 | |
| 2024 | LLM as Agent, GPT-4 baseline | Accuracy | 86.9 | split: test · subset=English USMLE problems targeting specific ethnic groups · approach=agent with online search | Unveiling Performance Challenges of Large Language Models in Low-Resource Healthcare: A Demographic Fairness PerspectiveSource quoteL116: LLM as Agent │ GPT-4 │ 66.7 │ 53.3 │ 86.9 │ 70.0 │ 36.8 │ 36.8 |
| 2024 | GPT-4 baseline | Accuracy Index | 0.84 | MedQA dataset, comprised of USMLE questions; score reported in the accuracy-versus-safe… | Ensuring Safety and Trust: Analyzing the Risks of Large Language Models in MedicineSource quoteL344: Safety Index in Figure 3. A model positioned on the diagonal line in Figure 3 would indicate a balanced performance between accuracy and safety. However, we observe that all models have a higher Accuracy Index than Safety Index. The best-performing model, GPT-4, shows a difference of 0.11 between its Accuracy Index and Safety Index (0.84 versus 0.73). The largest discrepancy is found in the Meditron-70B model, which is fine-tuned for the medical domain, with a gap of 0.27 between its Accuracy Index and Safety Index (0.52 versus 0.25). |
| 2024 | RadFM baseline | Accuracy↑ | 0.230 | MultiMedEval QA on the official split; multiple-choice answers selected by BLEU compari… | MultiMedEval: A Benchmark and a Toolkit for Evaluating Medical Vision-Language ModelsSource quoteL595: 0.230 |
| 2024 | LLaVAMed baseline | Accuracy↑ | 0.241 | MultiMedEval QA on the official split; multiple-choice answers selected by BLEU compari… | MultiMedEval: A Benchmark and a Toolkit for Evaluating Medical Vision-Language ModelsSource quoteL597: 0.241 |
| 2024 | GPT-4o baseline | accuracy | 88% | split: test · few-shot · prompting=few-shot | From Medprompt to o1: Exploration of Run-Time Strategies for Medical Challenge Problems and BeyondSource quoteL196: The latest model in the GPT-4 series, GPT-4o (August 2024), introduces a new balance between cost and accuracy. Compared to GPT-4 Turbo, GPT-4o consistently offers both improved accuracy and lower costs across all prompting strategies. As illustrated in Figure~\ref{fig:cost}, GPT-4o significantly shifts the cost-accuracy Pareto frontier, outperforming GPT-4 Turbo on both metrics. While o1-preview excels in terms of absolute accuracy, GPT-4o offers a well-balanced solution with strong performance at a lower cost. For example, increasing from 88% \rightarrow 92% \rightarrow 96% accuracy on the MedQA dataset each requires an order of magnitude increase in price ({\approx}\5 \rightarrow {\approx}\50 \rightarrow {\approx}\500) with the GPT-4o Few-shot, GPT-4o Medprompt, and o1-preview (5x ensemble) strategies respectively. Depending on the specific use case and overall system setup, it is crucial to carefully consider cost-benefit tradeoffs and to optimize resources according to goals and preferences. |
| 2024 | GPT-4o baseline | accuracy | 92% | split: test · few-shot · prompting=Medprompt | From Medprompt to o1: Exploration of Run-Time Strategies for Medical Challenge Problems and BeyondSource quoteL196: The latest model in the GPT-4 series, GPT-4o (August 2024), introduces a new balance between cost and accuracy. Compared to GPT-4 Turbo, GPT-4o consistently offers both improved accuracy and lower costs across all prompting strategies. As illustrated in Figure~\ref{fig:cost}, GPT-4o significantly shifts the cost-accuracy Pareto frontier, outperforming GPT-4 Turbo on both metrics. While o1-preview excels in terms of absolute accuracy, GPT-4o offers a well-balanced solution with strong performance at a lower cost. For example, increasing from 88% \rightarrow 92% \rightarrow 96% accuracy on the MedQA dataset each requires an order of magnitude increase in price ({\approx}\5 \rightarrow {\approx}\50 \rightarrow {\approx}\500) with the GPT-4o Few-shot, GPT-4o Medprompt, and o1-preview (5x ensemble) strategies respectively. Depending on the specific use case and overall system setup, it is crucial to carefully consider cost-benefit tradeoffs and to optimize resources according to goals and preferences. |
| 2024 | o1-preview baseline | accuracy | 96% | split: test · inference-strategy=5x ensemble | From Medprompt to o1: Exploration of Run-Time Strategies for Medical Challenge Problems and BeyondSource quoteL196: The latest model in the GPT-4 series, GPT-4o (August 2024), introduces a new balance between cost and accuracy. Compared to GPT-4 Turbo, GPT-4o consistently offers both improved accuracy and lower costs across all prompting strategies. As illustrated in Figure~\ref{fig:cost}, GPT-4o significantly shifts the cost-accuracy Pareto frontier, outperforming GPT-4 Turbo on both metrics. While o1-preview excels in terms of absolute accuracy, GPT-4o offers a well-balanced solution with strong performance at a lower cost. For example, increasing from 88% \rightarrow 92% \rightarrow 96% accuracy on the MedQA dataset each requires an order of magnitude increase in price ({\approx}\5 \rightarrow {\approx}\50 \rightarrow {\approx}\500) with the GPT-4o Few-shot, GPT-4o Medprompt, and o1-preview (5x ensemble) strategies respectively. Depending on the specific use case and overall system setup, it is crucial to carefully consider cost-benefit tradeoffs and to optimize resources according to goals and preferences. |
| 2023 | Self-Explain proposed | Test accuracy | 57.5 | split: test · few-shot · backbone=GPT-3.5-turbo · exemplars=5 | SELF-EXPLAIN: Teaching Large Language Models to Reason Complex Questions by ThemselvesSource quoteL174: 57.5 |
| 2023 | Self-Explain w/ Multi-Exp proposed | Test accuracy | 59.6 | split: test · few-shot · backbone=GPT-3.5-turbo · exemplars=5 · self-explanations-per-exemplar=5 | SELF-EXPLAIN: Teaching Large Language Models to Reason Complex Questions by ThemselvesSource quoteL177: 59.6 |
| 2023 | Active Exemplar Selection (table label: Active Selection) proposed | Accuracy | 62.51 | In-context exemplar-selection comparison; model, split, and exemplar count are not spec… | In-Context Exemplars as Clues to Retrieving from Large Associative MemorySource quoteL152: Active Selection │ {62.51} │ {59.86} |
| 2023 | PMC-LLaMA proposed | ACC | 56.36 | params=13B | PMC-LLaMA: Towards Building Open-source Language Models for MedicineSource quoteL271: PMC-LLaMA │ 13B │ 56.36 │ 56.04 │ 77.9 │ 64.43 |
| 2023 | MedAgents MC framework (GPT-3.5) proposed | Acc | 63.7 | split: test · 0-shot · model=GPT-3.5-Turbo · option-domain-agents=2 · question-domain-agents=5 | MedAgents: Large Language Models as Collaborators for Zero-shot Medical ReasoningSource quoteL205: \quad - \texttt{GPT-3.5} │ 63.7 │ 58.3 │ 72.9 │ 65.3 │ 77.8 │ 81.3 │ 79.2 │ 82.7 │ 79.4 |
| 2023 | ChiMed-GPT proposed non-standard slice | Accuracy | 44.50 | 5-shot · subset=Chinese MCMLE | ChiMed-GPT: A Chinese Medical Large Language Model with Full Training Regime and Better Alignment to Human PreferencesSource quoteL420: 44.50 |
| 2023 | KnowGPT proposed | accuracy | 78.1% | fine-tuned · llm-tuning=none | KnowGPT: Knowledge Graph based Prompting for Large Language ModelsSource quoteL479: \texttt{KnowGPT} │ 81.8% │ 92.4% │ 78.1% |
| 2023 | Human CoT baseline | Test accuracy | 55.6 | split: test · few-shot · backbone=GPT-3.5-turbo · exemplars=5 | SELF-EXPLAIN: Teaching Large Language Models to Reason Complex Questions by ThemselvesSource quoteL170: 55.6 |
| 2023 | Random baseline | Accuracy | 60.01 | In-context exemplar-selection comparison; model, split, and exemplar count are not spec… | In-Context Exemplars as Clues to Retrieving from Large Associative MemorySource quoteL149: Random │ 60.01 │ {54.59} |
| 2023 | GPT-3.5 Zero-shot CoT baseline | Acc | 52.1 | split: test · 0-shot · model=GPT-3.5-Turbo · prompting=chain-of-thought | MedAgents: Large Language Models as Collaborators for Zero-shot Medical ReasoningSource quoteL198: \quad - \texttt{Zero-shot CoT} │ 52.1 │ 50.2 │ 72.3 │ 64.9 │ 76.6 │ 80.1 │ 71.6 │ 77.1 │ 75.5 |
| 2023 | LLama 2-13B baseline | accuracy | 33.15% | 0-shot · model=Llama 2 · params=13B · subset=US, 5-option · backbone=13B · prompting=standard prompts | Examining User-Friendly and Open-Sourced Large GPT Models: A Survey on Language, Multimodal, and Scientific GPT ModelsSource quoteL871: LLama 2-13B \cite{touvron2023llama_2} │ 27.23 │ 25.63 │ 24.40 │ 24.64 │ 30.36 │ 29.79 │ 30.29 │ 29.79 │ 33.15 │ 30.64 │ 30.16 │ 28.91 │ 37.39 │ 41.32 │ {42.42} │ 42.18 |
| 2023 | LLama 2-13B baseline | accuracy | 42.42% | 3-shot · model=Llama 2 · params=13B · subset=US, 4-option · backbone=13B · prompting=standard prompts | Examining User-Friendly and Open-Sourced Large GPT Models: A Survey on Language, Multimodal, and Scientific GPT ModelsSource quoteL871: LLama 2-13B \cite{touvron2023llama_2} │ 27.23 │ 25.63 │ 24.40 │ 24.64 │ 30.36 │ 29.79 │ 30.29 │ 29.79 │ 33.15 │ 30.64 │ 30.16 │ 28.91 │ 37.39 │ 41.32 │ {42.42} │ 42.18 |
| 2023 | MedPaLM-2 baseline | overall accuracy | 86.5% | MedQA dataset for the United States Medical Licensing Examination (USMLE). | A Survey of Large Language Models in Medicine: Progress, Application, and ChallengeSource quoteL540: Examination (USMLE), MedPaLM-211 achieves a competitive overall accuracy of 86.5% compared to human experts (87.0%), surpassing previous state-of-the-art method MedPaLM10 by a large margin (19%). |
| 2023 | Human experts baseline | overall accuracy | 87.0% | Human-expert result cited as the comparison on the MedQA USMLE evaluation. | A Survey of Large Language Models in Medicine: Progress, Application, and ChallengeSource quoteL540: Examination (USMLE), MedPaLM-211 achieves a competitive overall accuracy of 86.5% compared to human experts (87.0%), surpassing previous state-of-the-art method MedPaLM10 by a large margin (19%). |
| 2022 | MoEBQA proposed | Test Accuracy | 41.6 | split: test | Mixture-of-Experts for Biomedical Question AnsweringSource quoteL319: MoEBQA{} │ 39.9 │ 41.6 |
| 2022 | MoEBQA w/o MoE Extension ablation | Test Accuracy | 38.7 | split: test | Mixture-of-Experts for Biomedical Question AnsweringSource quoteL323: w/o MoE Extension │ 38.3~(1.6\downarrow) │ 38.7~(2.9\downarrow) |
| 2022 | Flan-PaLM 540B baseline | Multiple-choice question accuracy | 67.6% | split: test · cot · params=540B · options=4 | Large language models encode clinical knowledgeSource quoteL471: MedQA 4 options │ 60.3 │ 67.6 |
| 2021 | RoBERTa-wwm-ext-large baseline | Accuracy | 70.10% | split: test · fine-tuned · subset=MCMLE · options=4 · backbone=RoBERTa-wwm-ext-large · information-source=33 medical textbooks | MLEC-QA: A Chinese Multi-Choice Biomedical Question Answering DatasetSource quoteL715: 70.10 |
| 2018 | R-NET non-standard slice | accuracy | 64.5 | split: test | Medical Exam Question Answering with Large-scale Reading ComprehensionSource quoteL270: 64.5 |
| 2018 | SeaReader (ensemble) non-standard slice | accuracy | 75.3 | split: test | Medical Exam Question Answering with Large-scale Reading ComprehensionSource quoteL276: 75.3 |