Abstract
OpenAI’s o1-preview model has established a new benchmark for artificial intelligence in medicine, outperforming GPT-4 even when the latter is augmented by the sophisticated "Medprompt" strategy. This study explores the performance of "reasoning-native" models, revealing that traditional few-shot prompting can actually hinder o1’s accuracy. By evaluating o1-preview across diverse benchmarks, including the USMLE-style MedQA and the 2024 Japanese Medical Licensing Exam, the researchers demonstrate that while o1-preview achieves record-breaking results, it necessitates a fundamental shift in prompt engineering and a careful consideration of the cost-accuracy trade-off.
Introduction
For the past year, the "Medprompt" strategy—integrating few-shot learning, chain-of-thought (CoT) reasoning, and ensembling—represented the gold standard for adapting general-purpose LLMs to the medical domain without intensive fine-tuning. With the release of OpenAI’s o1-preview, which utilizes reinforcement learning to perform internal reasoning, new questions arise: Does a reasoning-native model still benefit from complex run-time steering? How does it handle high-stakes medical nuances? And is the significant computational cost of its "thinking" phase justified by the gains in accuracy?
Methodology
The researchers compared o1-preview against the GPT-4 family (GPT-4, GPT-4 Turbo, and GPT-4o) using several run-time strategies:
- Zero-shot: Simple prompting without examples.
- Few-shot (kNN): Providing contextually similar medical cases retrieved from a database.
- Medprompt: A combination of kNN few-shot, automated CoT, and choice-shuffle ensembling.
- Extended Reasoning: Explicitly prompting o1 to "think carefully" to increase reasoning tokens.
- Ensembling: Running multiple iterations (up to 15x) with shuffled answer choices to utilize majority voting.
Datasets
Performance was measured across a robust suite of benchmarks:
- Standard Benchmarks: MedQA (USMLE-style), MedMCQA, NCLEX (Nursing), and medical subsets of MMLU (e.g., Clinical Knowledge, Anatomy).
- JMLE-2024: A newly curated benchmark based on the 2024 Japanese Medical Licensing Exam, ensuring the model could not have memorized the answers during training and testing its reasoning in non-English contexts.
Results and Discussion
Performance Breakthroughs and Benchmark Saturation
o1-preview achieved a staggering 96.0% accuracy on the MedQA (USMLE) benchmark, significantly surpassing the 90.2% achieved by GPT-4 with Medprompt. On many MMLU subsets, the model is reaching 98-99% accuracy, suggesting that these benchmarks are nearing saturation and that remaining errors may stem from noise or flaws within the datasets themselves.
The Shift in Prompt Engineering
A critical finding was the counter-intuitive impact of few-shot prompting on o1-preview. While few-shot examples are a staple of prompt engineering for previous models, they actually decreased o1's accuracy. This suggests that excessive context may interfere with the model's internalized reasoning processes. Conversely, ensembling remained highly effective, serving as a variance reduction technique that further boosted performance.
The Pareto Frontier: Accuracy vs. Cost
The study mapped accuracy against API costs, revealing a clear Pareto frontier. While o1-preview is the absolute leader in performance, GPT-4o remains the most cost-effective "value" option. Achieving the jump from 92% to 96% accuracy on MedQA requires a 10x to 100x increase in cost due to the high price of reasoning tokens and the necessity of ensembling for peak results.
Conclusion and Future Directions
While o1-preview sets a new standard, its "black box" reasoning—where reasoning tokens are hidden from the API—presents challenges for auditing clinical logic. As benchmarks saturate, the community requires more complex, open-ended clinical reasoning challenges. Future research should focus on "metareasoning" systems that can dynamically decide whether a query requires a cheap model or the expensive, high-powered reasoning of o1, optimizing both performance and cost.
Summary updated