LIVE · Image Quality Assessment

59 papers · 113 extracted observations · image quality assessment · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Image Quality Assessment: proposed/measured results on test (including papers where test split is standard/implicit).

0.80.80.91.0201420202026NIQE: 0.922 (2014)BLISS-C: 0.943 (2014)CNN: 0.953 (2014)SSIM+SOM: 0.933 (2015)BRISQUE+SOM: 0.952 (2015)MT-RankIQA: 0.973 (2019)CLRIQA+FT (Proposed): 0.979 (2019)RADN: 0.905 (2021)Unpaired-IQA (ER-IQA; reported as “Ours”): 0.785 (2021)DeepFL-IQA: 0.894 (2021)VTAMIQ: 0.974 (2021)Proposed query-based black-box attack: 0.3148 (2024)HyperIQA (/w ours; global monotonicity optimization): 0.971 (2025)Life-IQA: 0.822 (2026)
Click any point on the timeline to inspect method, protocol, and paper.
#MethodScore ↑YearProtocol / SettingsPaper & Evidence
1CLRIQA+FT (Proposed) SOTA frontier0.9792019-11-01test-sub-images=60 · train-test-split=80/20 · Fine-tuned after pre-training; evaluation uses a random 80/20 train/test split, and a…Controllable List-wise Ranking for Universal No-reference Image Quality Assessment
Source quote
CLRIQA+FT (Proposed) │ 0.979 │ 0.980 │ 0.953 │ 0.958 │ 0.935 │ 0.929 │ 0.821 │ 0.851 │ 0.921 │ 0.925\cr
2VTAMIQ (+1 variant)0.9742021-10-01Cross-database evaluation; trained on KADID-10k and tested on LIVE.VTAMIQ: Transformers for Attention Modulated Image Quality Assessment
Source quote
VTAMIQ (ours) │ 0.874 │ 0.899 │ 0.957 │ 0.907 │ 0.974 │ 0.897
3MT-RankIQA SOTA frontier0.9732019-01-01distortions=ALL · split_protocol=random 80/20 reference-image train/test split, averaged over 10 runs · Random 80%/20% reference-image train/test split, repeated 10 times and averaged; rank…Exploiting Unlabeled Data in CNNs by Self-Supervised Learning to Rank.
Source quote
MT-RankIQA │ 0.971 │ 0.978 │ 0.985 │ 0.979 │ 0.969 │ 0.973
4HyperIQA (/w ours; global monotonicity optimization)0.9712025-01-01split-strategy=4:1 by reference image · cross-validation=10-fold · 10-fold cross-validation; training-testing split 4:1 by reference image; median testi…Differentiable Low-computation Global Correlation Loss for Monotonicity Evaluation in Quality Assessment
Source quote
HyperIQA (/w ours) │ 0.935 │ 0.914 │ 0.972 │ 0.971
5CNN SOTA frontier0.9532014-01-01Overall evaluation across distortion types; the supplied excerpt does not include the…Convolutional Neural Networks for No-Reference Image Quality Assessment
Source quote
0.953
6BRISQUE+SOM (+1 variant)0.9522015-01-01All distorted images; average BRISQUE scores over N=10 top-scored object-like regions…SOM: Semantic obviousness metric for image quality assessment
Source quote
0.952
7BLISS-C (+1 variant)0.9432014-01-01ALL4 (JP2K, JPEG, WN, and BLUR combined); trained on synthetic scores from 3300 Flick…Beyond Human Opinion Scores: Blind Image Quality Assessment Based on Synthetic Scores
Source quote
0.943
8RADN0.9052021-01-01training_data=PIPAL · Cross-dataset evaluation; trained on the PIPAL training set and tested on the full LI…Region-Adaptive Deformable Network for Image Quality Assessment
Source quote
RADN │ 0.747 │ 0.796 │ 0.905 │ 0.878
9Life-IQA0.8222026-01-01Cross-dataset evaluation: trained on KonIQ and tested on LIVE.Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature Decoupling
Source quote
Life-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}}
10Unpaired-IQA (ER-IQA; reported as “Ours”)0.7852021-05-01evaluation=cross-dataset · training-dataset=LIVEC · reference-selection=within-dataset; no train-test content overlap · Cross-dataset test; the table labels this as authentic-and-synthetic (A. & S.); synth…ER-IQA: Boosting Perceptual Quality Assessment Using External Reference Images
Source quote
CSIQ │ LIVE │ 0.877 │ 0.926 │ 0.928 \multirow{2}{*}{A. \ │ S.} │ LIVEC │ LIVE │ 0.746 │ – │ 0.785
11Proposed query-based black-box attack0.31482024-01-01resolution=224x224 · model=DBCNN · attack=query-based black-box · queries=up to 8000 · DBCNN attack result on the test split; models retrained on the dataset's 80% training…Exploring Vulnerabilities of No-Reference Image Quality Assessment Models: A Query-Based Black-Box Method
Source quote
\multirow{-5}{*}{DBCNN} │ Ours │ 0.3148 │ 0.3982 │ 0.2204 │ 21.87 │ {0.896} │ {0.127}
Other primary task on LIVE: Image Quality Assessment · SRCC ↑ · test (8 papers)
#MethodScore ↑YearProtocol / SettingsPaper & Evidence
1DEIQT SOTA frontier (+1 variant)0.982023-01-01train_fraction=80% · Standard evaluation: 80% of images for training and 20% for testing; 10 repetitions, …Data-Efficient Image Quality Assessment with Attention-Panel Decoder
Source quote
Blind Image Quality Assessment (BIQA) is a fundamental task in computer vision, which however remains unresolved due to the complex distortion conditions and diversified image contents. To confront this challenge, we in this paper propose a novel BIQA pipeline based on the Transformer architecture, which achieves an efficient quality-aware feature representation with much fewer data. More specifically, we consider the traditional fine-tuning in BIQA as an interpretation of the pre-trained model. In this way, we further introduce a Transformer decoder to refine the perceptual information of the CLS token from different perspectives. This enables our model to establish the quality-aware feature manifold efficiently while attaining a strong generalization capability. Meanwhile, inspired by the subjective evaluation behaviors of human, we introduce a novel attention panel mechanism, which improves the model performance and reduces the prediction uncertainty simultaneously. The proposed BIQA method maintains a lightweight design with only one layer of the decoder, yet extensive experiments on eight standard BIQA datasets (both synthetic and authentic) demonstrate its superior performance to the state-of-the-art BIQA methods, i.e., achieving the SRCC values of 0.875 (vs. 0.859 in LIVEC) and 0.980 (vs. 0.969 in LIVE). Checkpoints, logs and code will be available at \url{https://github.com/narthchin/DEIQT}.
2MR-IQA (Diff)0.9772023-02-01repeats=10 random splits · test-patches=8 randomly sampled; horizontal/vertical flipping · patch-selection=difference masking · train-test-split=80/20 by reference image · 80/20 train/test split by reference image; average over ten random splits. Diff maski…Mask Reference Image Quality Assessment
Source quote
Ours (Diff) │ 0.977 │ 0.980 │ 0.947 │ 0.952 │ 0.912 │ 0.930 │ 0.952 │ 0.955 \Xhline{1.2pt} \specialrule{0em}{1pt}{1pt}
3DB-CNN SOTA frontier0.9682019-07-01Per-database score from the ablation-results table; the cited lines do not specify th…Blind Image Quality Assessment Using A Deep Bilinear Convolutional Neural Network
Source quote
DB-CNN │ {\bf 0.968} │ {\bf0.946} │ {\bf 0.816} │ {\bf 0.851}
4Proposed BIQA method (Ours, All databases)0.9612020-01-01resolution=original image size · training-data=all six IQA databases · Trained on all six IQA databases using intra-database image pairs; tested at original…Learning To Blindly Assess Image Quality In The Laboratory And Wild
Source quote
Ours (All databases) │ {\bf 0.961} │ {\bf 0.907} │ {\bf 0.855} │ {\bf 0.863} │ {\bf 0.851} │ {\bf 0.894}
5CSFIQA0.9332024-11-01evaluation=cross-dataset; no parameter adjustment · training-dataset=CSIQ · Cross-dataset validation; trained on CSIQ and tested on LIVE without parameter adjust…Scale Contrastive Learning with Selective Attentions for Blind Image Quality Assessment
Source quote
ours │ 0.785 │ 0.805 │ 0.762 │ 0.838 │ 0.786 │ 0.933
6DUBMA0.932025-01-01Correlation with MOS on the subject-rated image set; trained on synthetic image pairs…Deep Opinion-Unaware Blind Image Quality Assessment by Learning and Adapting from Multiple Annotators
Source quote
0.930 0.840
7CVRKD-IQA NAR-student + Content-variant NAR0.9132022-01-01reference=content-variant non-aligned HQ · training-data=KADID-10K · Cross-dataset evaluation after training on synthetic Kaddid-10K; content-variant non-…Content-Variant Reference Image Quality Assessment via Knowledge Distillation
Source quote
NAR-student + Content-variant NAR │ 0.913 │ 0.829 │ 0.691
8DiffV^2IQA0.8052025-01-01evaluation=cross-dataset · training-dataset=PIPAL · Cross-dataset test: trained on PIPAL and tested on LIVE; table reports PLCC then SRCC…Diffusion Model-Based Visual Compensation Guidance and Visual Difference Analysis for No-Reference Image Quality Assessment
Source quote
DiffV^2IQA │ 0.769 │ 0.805 │ 0.729 │ 0.652
Other primary task on LIVE: Image Quality Assessment · PLCC ↑ · test (7 papers)
#MethodScore ↑YearProtocol / SettingsPaper & Evidence
1MR-IQA (Diff) SOTA frontier0.982023-02-01repeats=10 random splits · test-patches=8 randomly sampled; horizontal/vertical flipping · patch-selection=difference masking · train-test-split=80/20 by reference image · 80/20 train/test split by reference image; average over ten random splits. Diff maski…Mask Reference Image Quality Assessment
Source quote
Ours (Diff) │ 0.977 │ 0.980 │ 0.947 │ 0.952 │ 0.912 │ 0.930 │ 0.952 │ 0.955 \Xhline{1.2pt} \specialrule{0em}{1pt}{1pt}
2YOTO (Ours-T)0.9712023-10-01epochs=200 · training=joint KonIQ+LIVE+CSIQ · Mixed-dataset joint training for NR IQA; 80/20 train/test split for each dataset, 200…UNIQA: A Unified Framework for Both Full-Reference and No-Reference Image Quality Assessment
Source quote
0.971
3DeepWSD w/P4 SOTA frontier0.96092022-08-01patch-size=4×4 · Patch size 4×4 (P4); quality-prediction evaluation.DeepWSD: Projecting Degradations in Perceptual Space to Wasserstein Distance in Deep Feature Space
Source quote
DeepWSD w/P4 │ 0.8697 │ 0.8741 │ 0.6932 │ 0.9609 │ 0.9624 │ 0.8378 │ 0.9503 │ 0.9652 │ 0.8297 │ 0.8434 │ 0.8883 │ 0.7076
4Saak-feature full-reference IQA (Proposed) SOTA frontier0.94412019-05-01distortion=JPEG · Correlation between subjective and objective scores after nonlinear regression; JPEG …Compressed Image Quality Assessment Based on Saak Features
Source quote
Proposed │ 0.9441 │ 0.914 │ 0.7517 │ 0.9625 │ 0.9542 │ 0.809 │ 0.9878 │ 0.9691 │ 0.8489 │ 0.9813 │ 0.9737 │ 0.861
5DUBMA0.9182025-01-01Correlation with MOS on the subject-rated image set; trained on synthetic image pairs…Deep Opinion-Unaware Blind Image Quality Assessment by Learning and Adapting from Multiple Annotators
Source quote
0.918 0.859
6MQAF-R0.9132026-02-01Cross-dataset evaluation: trained on KADID-10K and tested on LIVE, without fine-tunin…Image Quality Assessment: Exploring Quality Awareness via Memory-driven Distortion Patterns Matching
Source quote
MQAF-R (Ours) │ \bf 0.913 │ \bf0.941 │ \bf 0.903 │ 0.910 │ \bf0.845 │ \bf 0.847
7Life-IQA0.82026-01-01Cross-dataset evaluation: trained on KonIQ and tested on LIVE.Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature Decoupling
Source quote
Life-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}}
Other primary task on LIVE: Image Quality Assessment · LCC ↑ · test (3 papers)
#MethodScore ↑YearProtocol / SettingsPaper & Evidence
1WaDIQaM-FR SOTA frontier0.982018-01-01evaluation=10 random splits · reference-type=full-reference · patches-per-image=32 · Full LIVE evaluation; 32 patches per image; split by reference image (17 training, 6 …Deep Neural Networks for No-Reference and Full-Reference Image Quality Assessment
Source quote
WaDIQaM-FR (proposed) │ \bf{0.980} │ 0.970
2MT-RankIQA0.9762019-01-01distortions=ALL · split_protocol=random 80/20 reference-image train/test split, averaged over 10 runs · Random 80%/20% reference-image train/test split, repeated 10 times and averaged; rank…Exploiting Unlabeled Data in CNNs by Self-Supervised Learning to Rank.
Source quote
MT-RankIQA │ 0.972 │ 0.978 │ 0.988 │ 0.982 │ 0.971 │ 0.976
3NIMA(Inception-v2) SOTA frontier0.5522017-09-01Trained on AVA and tested on LIVE; cross-dataset evaluation.NIMA: Neural Image Assessment
Source quote
AVA~\cite{murray2012ava} │ 0.552 │ 0.514 │ 0.636 │ 0.567
Other primary task on LIVE: Image Quality Assessment · PCC ↑ (2 papers)
#MethodScore ↑YearProtocol / SettingsPaper & Evidence
1GMSD SOTA frontier0.962013-08-01channel=luminance · LIVE database (779 distorted images); evaluated on the luminance channel; PCC compute…Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality Index
Source quote
0.960
2SOS-H-rNSE0.9462015-10-01distortions=JP2K, JPEG, WN, GB · Common distortion types JP2K, JPEG, WN, and GB; SOS-H-rNSE configuration.Learn to Evaluate Image Perceptual Quality Blindly from Statistics of Self-similarity
Source quote
From TABLE~\ref{Table_2}, we can observe that both SOS-MD and SOS-H show good performance on the three databases in terms of PCC and SRC. The best results on all the three databases are achieved by the method SOS-H-rNSE, with PCC values 0.946, 0.933, and 0.937 on the three databases, respectively. For every single distortion type, it also demonstrates PCC and SRC values consistently higher than 0.9. Note that due to the scale difference of subjective scores on the three databases, the resulting RMSE values range differently.