LIVE

59 papers · 113 extracted observations · image quality assessment · vision · Markdown · CSV · JSON API

Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)

Image Quality Assessment: proposed/measured results on test (including papers where test split is standard/implicit).

0.80.80.91.0201420202026NIQE: 0.922 (2014)BLISS-C: 0.943 (2014)CNN: 0.953 (2014)SSIM+SOM: 0.933 (2015)BRISQUE+SOM: 0.952 (2015)MT-RankIQA: 0.973 (2019)CLRIQA+FT (Proposed): 0.979 (2019)RADN: 0.905 (2021)Unpaired-IQA (ER-IQA; reported as “Ours”): 0.785 (2021)DeepFL-IQA: 0.894 (2021)VTAMIQ: 0.974 (2021)Proposed query-based black-box attack: 0.3148 (2024)HyperIQA (/w ours; global monotonicity optimization): 0.971 (2025)Life-IQA: 0.822 (2026)
Click any point on the timeline to inspect method, protocol, and paper.

Showing 35 of 35 matching observations.

YearMethodMetricScoreProtocol / FacetsPaper & Evidence
2025Life-IQA proposedSROCC0.822Image Quality Assessment · split: testLife-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature Decoupling
Source quote
L239: Life-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}}
2025Life-IQA proposedPLCC0.800Image Quality Assessment · split: testLife-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature Decoupling
Source quote
L239: Life-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}}
2025HyperIQA (/w ours; global monotonicity optimization) proposedSROCC0.971Image Quality Assessment · split: test · split-strategy=4:1 by reference image · cross-validation=10-foldDifferentiable Low-computation Global Correlation Loss for Monotonicity Evaluation in Quality Assessment
Source quote
L164: HyperIQA (/w ours) │ 0.935 │ 0.914 │ 0.972 │ 0.971
2024DiffV^2IQA proposedSRCC0.805Image Quality Assessment · split: test · evaluation=cross-dataset · training-dataset=PIPALDiffusion Model-Based Visual Compensation Guidance and Visual Difference Analysis for No-Reference Image Quality Assessment
Source quote
L379: DiffV^2IQA │ 0.769 │ 0.805 │ 0.729 │ 0.652
2024CSFIQA proposedSRCC0.933Image Quality Assessment · split: test · evaluation=cross-dataset; no parameter adjustment · training-dataset=CSIQScale Contrastive Learning with Selective Attentions for Blind Image Quality Assessment
Source quote
L181: ours │ 0.785 │ 0.805 │ 0.762 │ 0.838 │ 0.786 │ 0.933
2024Proposed query-based black-box attack proposedSROCC0.3148Image Quality Assessment · split: test · resolution=224x224 · model=DBCNN · attack=query-based black-box · queries=up to 8000Exploring Vulnerabilities of No-Reference Image Quality Assessment Models: A Query-Based Black-Box Method
Source quote
L228: \multirow{-5}{*}{DBCNN} │ Ours │ 0.3148 │ 0.3982 │ 0.2204 │ 21.87 │ {0.896} │ {0.127}
2024ExIQA proposedSRCC0.922Image Quality Assessment · split: test · 0-shotExIQA: Explainable Image Quality Assessment Using Distortion Attributes
Source quote
L276: ExIQA │ LIVE │ 0.922
2023DEIQT proposedSRCC0.980Image Quality Assessment · split: test · train_fraction=80%Data-Efficient Image Quality Assessment with Attention-Panel Decoder
Source quote
L4: Blind Image Quality Assessment (BIQA) is a fundamental task in computer vision, which however remains unresolved due to the complex distortion conditions and diversified image contents. To confront this challenge, we in this paper propose a novel BIQA pipeline based on the Transformer architecture, which achieves an efficient quality-aware feature representation with much fewer data. More specifically, we consider the traditional fine-tuning in BIQA as an interpretation of the pre-trained model. In this way, we further introduce a Transformer decoder to refine the perceptual information of the CLS token from different perspectives. This enables our model to establish the quality-aware feature manifold efficiently while attaining a strong generalization capability. Meanwhile, inspired by the subjective evaluation behaviors of human, we introduce a novel attention panel mechanism, which improves the model performance and reduces the prediction uncertainty simultaneously. The proposed BIQA method maintains a lightweight design with only one layer of the decoder, yet extensive experiments on eight standard BIQA datasets (both synthetic and authentic) demonstrate its superior performance to the state-of-the-art BIQA methods, i.e., achieving the SRCC values of 0.875 (vs. 0.859 in LIVEC) and 0.980 (vs. 0.969 in LIVE). Checkpoints, logs and code will be available at \url{https://github.com/narthchin/DEIQT}.
2023DEIQT proposedSRCC0.965Image Quality Assessment · split: test · train_fraction=20%Data-Efficient Image Quality Assessment with Attention-Panel Decoder
Source quote
L176: DEIQT │ 0.968 │ 0.965 │ 0.822 │ 0.792 │ 0.908 │ 0.888 [0.25pt]
2023DEIQT proposedSRCC0.932Image Quality Assessment · split: test · cross-dataset · training_dataset=CSIQData-Efficient Image Quality Assessment with Attention-Panel Decoder
Source quote
L157: DEIQT │ 0.733 │ 0.781 │ 0.744 │ 0.794 │ 0.781 │ 0.932
2023YOTO (Ours-T) proposedPLCC0.971Image Quality Assessment · split: test · epochs=200 · training=joint KonIQ+LIVE+CSIQUNIQA: A Unified Framework for Both Full-Reference and No-Reference Image Quality Assessment
Source quote
L363: 0.971
2023MR-IQA (Diff) proposedSRCC0.977Image Quality Assessment · split: test · repeats=10 random splits · test-patches=8 randomly sampled; horizontal/vertical flipping · patch-selection=difference masking · train-test-split=80/20 by reference imageMask Reference Image Quality Assessment
Source quote
L271: Ours (Diff) │ 0.977 │ 0.980 │ 0.947 │ 0.952 │ 0.912 │ 0.930 │ 0.952 │ 0.955 \Xhline{1.2pt} \specialrule{0em}{1pt}{1pt}
2023MR-IQA (Diff) proposedPLCC0.980Image Quality Assessment · split: test · repeats=10 random splits · test-patches=8 randomly sampled; horizontal/vertical flipping · patch-selection=difference masking · train-test-split=80/20 by reference imageMask Reference Image Quality Assessment
Source quote
L271: Ours (Diff) │ 0.977 │ 0.980 │ 0.947 │ 0.952 │ 0.912 │ 0.930 │ 0.952 │ 0.955 \Xhline{1.2pt} \specialrule{0em}{1pt}{1pt}
2022MANIQA proposedPLCC0.835Image Quality Assessment · split: test · cross-dataset · adaptation=none · training-dataset=PIPALMANIQA: Multi-dimension Attention Network for No-Reference Image Quality Assessment
Source quote
L294: MANIQA(ours) │ 0.835 │ 0.855 │ 0.704 │ 0.619
2022MANIQA proposedSROCC0.855Image Quality Assessment · split: test · cross-dataset · adaptation=none · training-dataset=PIPALMANIQA: Multi-dimension Attention Network for No-Reference Image Quality Assessment
Source quote
L294: MANIQA(ours) │ 0.835 │ 0.855 │ 0.704 │ 0.619
2022Note Generation system (incremental transcript chunks) proposed% copied42%Medical Note Generation · split: test · duration=3 weeks · clinician=CUser-Driven Research of Medical Note Generation Software
Source quote
L201: 42%
2022Note Generation system (incremental transcript chunks) proposedOverlap (ROUGE-L recall)22%Medical Note Generation · split: test · duration=3 weeks · clinician=CUser-Driven Research of Medical Note Generation Software
Source quote
L202: 22%
2022Note Generation system (incremental transcript chunks) proposed% copied50%Medical Note Generation · split: test · duration=3 weeks · clinician=DUser-Driven Research of Medical Note Generation Software
Source quote
L205: 50%
2022Note Generation system (incremental transcript chunks) proposedOverlap (ROUGE-L recall)34%Medical Note Generation · split: test · duration=3 weeks · clinician=DUser-Driven Research of Medical Note Generation Software
Source quote
L206: 34%
2022Note Generation system (incremental transcript chunks) proposed% copied13%Medical Note Generation · split: test · duration=3 weeks · clinician=EUser-Driven Research of Medical Note Generation Software
Source quote
L209: 13%
2022Note Generation system (incremental transcript chunks) proposedOverlap (ROUGE-L recall)19%Medical Note Generation · split: test · duration=3 weeks · clinician=EUser-Driven Research of Medical Note Generation Software
Source quote
L210: 19%
2022Proposed SFUDA proposedSROCC0.8577Image Quality Assessment · split: test · source-free-adaptation · seeds=5 · source-dataset=KonIQ-10K · adaptation-data=unlabeled target dataSource-free Unsupervised Domain Adaptation for Blind Image Quality Assessment
Source quote
L225: \multicolumn{2}{c|}{Ours} │ 0.5829/0.6024 │ 0.7574/0.7766 │ 0.7699/0.8121 │ 0.8577/0.8444
2022STFEE proposed non-standard slicePLCC0.7352Video Quality Assessment · split: test · subset=compressed-video subset (80 outputs) · score-normalization=[0,1]Deep Quality Assessment of Compressed Videos: A Subjective and Objective Study
Source quote
L267: \multicolumn{1}{l}{STFEE} │ 0.9203 │ 0.9098 │ 0.7352 │ 0.7451 │ 0.7883 │ 0.7682 │ 0.8813 │ 0.8775
2021Proposed model (trained on PIPAL train phase) proposedSRCC0.9263Image Quality Assessment · split: test · cross-dataset · train-data=PIPAL train phase · score-processing=normalized differential MOS converted to MOSDeep Learning-Based Distortion Sensitivity Prediction for Full-Reference Image Quality Assessment
Source quote
L354: 0.9263
2021Proposed model (trained on PIPAL train phase) proposedPLCC0.9211Image Quality Assessment · split: test · cross-dataset · train-data=PIPAL train phase · score-processing=normalized differential MOS converted to MOSDeep Learning-Based Distortion Sensitivity Prediction for Full-Reference Image Quality Assessment
Source quote
L355: 0.9211
2021Unpaired-IQA (ER-IQA; reported as “Ours”) proposedSROCC0.785Image Quality Assessment · split: test · evaluation=cross-dataset · training-dataset=LIVEC · reference-selection=within-dataset; no train-test content overlapER-IQA: Boosting Perceptual Quality Assessment Using External Reference Images
Source quote
L228: CSIQ │ LIVE │ 0.877 │ 0.926 │ 0.928 \multirow{2}{*}{A. \ │ S.} │ LIVEC │ LIVE │ 0.746 │ – │ 0.785
2021RADN proposedSROCC0.905Image Quality Assessment · split: test · training_data=PIPALRegion-Adaptive Deformable Network for Image Quality Assessment
Source quote
L237: RADN │ 0.747 │ 0.796 │ 0.905 │ 0.878
2019MT-RankIQA proposedLCC0.976Image Quality Assessment · split: test · fine-tuned · distortions=ALL · split_protocol=random 80/20 reference-image train/test split, averaged over 10 runsExploiting Unlabeled Data in CNNs by Self-Supervised Learning to Rank.
Source quote
L1264: MT-RankIQA │ 0.972 │ 0.978 │ 0.988 │ 0.982 │ 0.971 │ 0.976
2019MT-RankIQA proposedSROCC0.973Image Quality Assessment · split: test · fine-tuned · distortions=ALL · split_protocol=random 80/20 reference-image train/test split, averaged over 10 runsExploiting Unlabeled Data in CNNs by Self-Supervised Learning to Rank.
Source quote
L1281: MT-RankIQA │ 0.971 │ 0.978 │ 0.985 │ 0.979 │ 0.969 │ 0.973
2019RRLRIQA proposed non-standard sliceSROCC0.956Image Quality Assessment · split: test · fine-tuned · repeats=20; median · split-protocol=80/20 grouped by reference image · training-target=objective-score rewards, not MOSNo-Reference Image Quality Assessment with Reinforcement Recursive List-Wise Ranking
Source quote
L367: 0.956
2019CLRIQA+FT (Proposed) proposedSROCC0.979Image Quality Assessment · split: test · fine-tuned · test-sub-images=60 · train-test-split=80/20Controllable List-wise Ranking for Universal No-reference Image Quality Assessment
Source quote
L289: CLRIQA+FT (Proposed) │ 0.979 │ 0.980 │ 0.953 │ 0.958 │ 0.935 │ 0.929 │ 0.821 │ 0.851 │ 0.921 │ 0.925\cr
2019Proposed BIQA method (Ours, All databases) proposedSRCC0.961Image Quality Assessment · split: test · resolution=original image size · training-data=all six IQA databasesLearning To Blindly Assess Image Quality In The Laboratory And Wild
Source quote
L110: Ours (All databases) │ {\bf 0.961} │ {\bf 0.907} │ {\bf 0.855} │ {\bf 0.863} │ {\bf 0.851} │ {\bf 0.894}
2018T/S AM (25k-hour beamformed simulation + 3.4k-hour sequence training + 300 hours live data) proposedWER10.20%Speech Recognition · split: test · params=100M · setting=far-field · training-data=25k-hour beamformed simulation; 3.4k-hour sequence training; 300 hours live data · language_model=5-gramDeveloping Far-Field Speaker System Via Teacher-Student Learning
Source quote
L166: 10.20
2016WaDIQaM-FR proposedLCC0.980Image Quality Assessment · split: test · evaluation=10 random splits · reference-type=full-reference · patches-per-image=32Deep Neural Networks for No-Reference and Full-Reference Image Quality Assessment
Source quote
L669: WaDIQaM-FR (proposed) │ \bf{0.980} │ 0.970
2013SF100 (supervised filter learning, 100 filters) proposed non-standard sliceSROCC0.920No Reference Image Quality Assessment · split: test · subset=all distortion categories · filters=100Real-Time No-Reference Image Quality Assessment Based on Filter Learning
Source quote