LIVE
59 papers · 113 extracted observations · image quality assessment · vision · Markdown · CSV · JSON API
Tasks on LIVEAll tasks (59)Image Quality Assessment (51)Blind Image Quality Assessment (1)Image Compression (1)Image Distortion Classification (1)Medical Note Generation (1)No Reference Image Quality Assessment (1)Speech Recognition (1)Super Resolution (1)
Primary tasks / metrics
Comparable Cohort Timeline (proposed/measured methods; excludes quoted baselines & ablations)
Image Quality Assessment: proposed/measured results on test (including papers where test split is standard/implicit).
Click any point on the timeline to inspect method, protocol, and paper.
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | CLRIQA+FT (Proposed) SOTA frontier | 0.979 | 2019-11-01 | test-sub-images=60 · train-test-split=80/20 · Fine-tuned after pre-training; evaluation uses a random 80/20 train/test split, and a… | Controllable List-wise Ranking for Universal No-reference Image Quality AssessmentSource quoteCLRIQA+FT (Proposed) │ 0.979 │ 0.980 │ 0.953 │ 0.958 │ 0.935 │ 0.929 │ 0.821 │ 0.851 │ 0.921 │ 0.925\cr |
| 2 | VTAMIQ (+1 variant) | 0.974 | 2021-10-01 | Cross-database evaluation; trained on KADID-10k and tested on LIVE. | VTAMIQ: Transformers for Attention Modulated Image Quality AssessmentSource quoteVTAMIQ (ours) │ 0.874 │ 0.899 │ 0.957 │ 0.907 │ 0.974 │ 0.897 |
| 3 | MT-RankIQA SOTA frontier | 0.973 | 2019-01-01 | distortions=ALL · split_protocol=random 80/20 reference-image train/test split, averaged over 10 runs · Random 80%/20% reference-image train/test split, repeated 10 times and averaged; rank… | Exploiting Unlabeled Data in CNNs by Self-Supervised Learning to Rank.Source quoteMT-RankIQA │ 0.971 │ 0.978 │ 0.985 │ 0.979 │ 0.969 │ 0.973 |
| 4 | HyperIQA (/w ours; global monotonicity optimization) | 0.971 | 2025-01-01 | split-strategy=4:1 by reference image · cross-validation=10-fold · 10-fold cross-validation; training-testing split 4:1 by reference image; median testi… | Differentiable Low-computation Global Correlation Loss for Monotonicity Evaluation in Quality AssessmentSource quoteHyperIQA (/w ours) │ 0.935 │ 0.914 │ 0.972 │ 0.971 |
| 5 | CNN SOTA frontier | 0.953 | 2014-01-01 | Overall evaluation across distortion types; the supplied excerpt does not include the… | Convolutional Neural Networks for No-Reference Image Quality AssessmentSource quote0.953 |
| 6 | BRISQUE+SOM (+1 variant) | 0.952 | 2015-01-01 | All distorted images; average BRISQUE scores over N=10 top-scored object-like regions… | SOM: Semantic obviousness metric for image quality assessmentSource quote0.952 |
| 7 | BLISS-C (+1 variant) | 0.943 | 2014-01-01 | ALL4 (JP2K, JPEG, WN, and BLUR combined); trained on synthetic scores from 3300 Flick… | Beyond Human Opinion Scores: Blind Image Quality Assessment Based on Synthetic ScoresSource quote0.943 |
| 8 | RADN | 0.905 | 2021-01-01 | training_data=PIPAL · Cross-dataset evaluation; trained on the PIPAL training set and tested on the full LI… | Region-Adaptive Deformable Network for Image Quality AssessmentSource quoteRADN │ 0.747 │ 0.796 │ 0.905 │ 0.878 |
| 9 | Life-IQA | 0.822 | 2026-01-01 | Cross-dataset evaluation: trained on KonIQ and tested on LIVE. | Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature DecouplingSource quoteLife-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}} |
| 10 | Unpaired-IQA (ER-IQA; reported as “Ours”) | 0.785 | 2021-05-01 | evaluation=cross-dataset · training-dataset=LIVEC · reference-selection=within-dataset; no train-test content overlap · Cross-dataset test; the table labels this as authentic-and-synthetic (A. & S.); synth… | ER-IQA: Boosting Perceptual Quality Assessment Using External Reference ImagesSource quoteCSIQ │ LIVE │ 0.877 │ 0.926 │ 0.928 \multirow{2}{*}{A. \ │ S.} │ LIVEC │ LIVE │ 0.746 │ – │ 0.785 |
| 11 | Proposed query-based black-box attack | 0.3148 | 2024-01-01 | resolution=224x224 · model=DBCNN · attack=query-based black-box · queries=up to 8000 · DBCNN attack result on the test split; models retrained on the dataset's 80% training… | Exploring Vulnerabilities of No-Reference Image Quality Assessment Models: A Query-Based Black-Box MethodSource quote\multirow{-5}{*}{DBCNN} │ Ours │ 0.3148 │ 0.3982 │ 0.2204 │ 21.87 │ {0.896} │ {0.127} |
Other primary task on LIVE: Image Quality Assessment · SRCC ↑ · test (8 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | DEIQT SOTA frontier (+1 variant) | 0.98 | 2023-01-01 | train_fraction=80% · Standard evaluation: 80% of images for training and 20% for testing; 10 repetitions, … | Data-Efficient Image Quality Assessment with Attention-Panel DecoderSource quoteBlind Image Quality Assessment (BIQA) is a fundamental task in computer vision, which however remains unresolved due to the complex distortion conditions and diversified image contents. To confront this challenge, we in this paper propose a novel BIQA pipeline based on the Transformer architecture, which achieves an efficient quality-aware feature representation with much fewer data. More specifically, we consider the traditional fine-tuning in BIQA as an interpretation of the pre-trained model. In this way, we further introduce a Transformer decoder to refine the perceptual information of the CLS token from different perspectives. This enables our model to establish the quality-aware feature manifold efficiently while attaining a strong generalization capability. Meanwhile, inspired by the subjective evaluation behaviors of human, we introduce a novel attention panel mechanism, which improves the model performance and reduces the prediction uncertainty simultaneously. The proposed BIQA method maintains a lightweight design with only one layer of the decoder, yet extensive experiments on eight standard BIQA datasets (both synthetic and authentic) demonstrate its superior performance to the state-of-the-art BIQA methods, i.e., achieving the SRCC values of 0.875 (vs. 0.859 in LIVEC) and 0.980 (vs. 0.969 in LIVE). Checkpoints, logs and code will be available at \url{https://github.com/narthchin/DEIQT}. |
| 2 | MR-IQA (Diff) | 0.977 | 2023-02-01 | repeats=10 random splits · test-patches=8 randomly sampled; horizontal/vertical flipping · patch-selection=difference masking · train-test-split=80/20 by reference image · 80/20 train/test split by reference image; average over ten random splits. Diff maski… | Mask Reference Image Quality AssessmentSource quoteOurs (Diff) │ 0.977 │ 0.980 │ 0.947 │ 0.952 │ 0.912 │ 0.930 │ 0.952 │ 0.955 \Xhline{1.2pt} \specialrule{0em}{1pt}{1pt} |
| 3 | DB-CNN SOTA frontier | 0.968 | 2019-07-01 | Per-database score from the ablation-results table; the cited lines do not specify th… | Blind Image Quality Assessment Using A Deep Bilinear Convolutional Neural NetworkSource quoteDB-CNN │ {\bf 0.968} │ {\bf0.946} │ {\bf 0.816} │ {\bf 0.851} |
| 4 | Proposed BIQA method (Ours, All databases) | 0.961 | 2020-01-01 | resolution=original image size · training-data=all six IQA databases · Trained on all six IQA databases using intra-database image pairs; tested at original… | Learning To Blindly Assess Image Quality In The Laboratory And WildSource quoteOurs (All databases) │ {\bf 0.961} │ {\bf 0.907} │ {\bf 0.855} │ {\bf 0.863} │ {\bf 0.851} │ {\bf 0.894} |
| 5 | CSFIQA | 0.933 | 2024-11-01 | evaluation=cross-dataset; no parameter adjustment · training-dataset=CSIQ · Cross-dataset validation; trained on CSIQ and tested on LIVE without parameter adjust… | Scale Contrastive Learning with Selective Attentions for Blind Image Quality AssessmentSource quoteours │ 0.785 │ 0.805 │ 0.762 │ 0.838 │ 0.786 │ 0.933 |
| 6 | DUBMA | 0.93 | 2025-01-01 | Correlation with MOS on the subject-rated image set; trained on synthetic image pairs… | Deep Opinion-Unaware Blind Image Quality Assessment by Learning and Adapting from Multiple AnnotatorsSource quote0.930 0.840 |
| 7 | CVRKD-IQA NAR-student + Content-variant NAR | 0.913 | 2022-01-01 | reference=content-variant non-aligned HQ · training-data=KADID-10K · Cross-dataset evaluation after training on synthetic Kaddid-10K; content-variant non-… | Content-Variant Reference Image Quality Assessment via Knowledge DistillationSource quoteNAR-student + Content-variant NAR │ 0.913 │ 0.829 │ 0.691 |
| 8 | DiffV^2IQA | 0.805 | 2025-01-01 | evaluation=cross-dataset · training-dataset=PIPAL · Cross-dataset test: trained on PIPAL and tested on LIVE; table reports PLCC then SRCC… | Diffusion Model-Based Visual Compensation Guidance and Visual Difference Analysis for No-Reference Image Quality AssessmentSource quoteDiffV^2IQA │ 0.769 │ 0.805 │ 0.729 │ 0.652 |
Other primary task on LIVE: Image Quality Assessment · PLCC ↑ · test (7 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | MR-IQA (Diff) SOTA frontier | 0.98 | 2023-02-01 | repeats=10 random splits · test-patches=8 randomly sampled; horizontal/vertical flipping · patch-selection=difference masking · train-test-split=80/20 by reference image · 80/20 train/test split by reference image; average over ten random splits. Diff maski… | Mask Reference Image Quality AssessmentSource quoteOurs (Diff) │ 0.977 │ 0.980 │ 0.947 │ 0.952 │ 0.912 │ 0.930 │ 0.952 │ 0.955 \Xhline{1.2pt} \specialrule{0em}{1pt}{1pt} |
| 2 | YOTO (Ours-T) | 0.971 | 2023-10-01 | epochs=200 · training=joint KonIQ+LIVE+CSIQ · Mixed-dataset joint training for NR IQA; 80/20 train/test split for each dataset, 200… | UNIQA: A Unified Framework for Both Full-Reference and No-Reference Image Quality AssessmentSource quote0.971 |
| 3 | DeepWSD w/P4 SOTA frontier | 0.9609 | 2022-08-01 | patch-size=4×4 · Patch size 4×4 (P4); quality-prediction evaluation. | DeepWSD: Projecting Degradations in Perceptual Space to Wasserstein Distance in Deep Feature SpaceSource quoteDeepWSD w/P4 │ 0.8697 │ 0.8741 │ 0.6932 │ 0.9609 │ 0.9624 │ 0.8378 │ 0.9503 │ 0.9652 │ 0.8297 │ 0.8434 │ 0.8883 │ 0.7076 |
| 4 | Saak-feature full-reference IQA (Proposed) SOTA frontier | 0.9441 | 2019-05-01 | distortion=JPEG · Correlation between subjective and objective scores after nonlinear regression; JPEG … | Compressed Image Quality Assessment Based on Saak FeaturesSource quoteProposed │ 0.9441 │ 0.914 │ 0.7517 │ 0.9625 │ 0.9542 │ 0.809 │ 0.9878 │ 0.9691 │ 0.8489 │ 0.9813 │ 0.9737 │ 0.861 |
| 5 | DUBMA | 0.918 | 2025-01-01 | Correlation with MOS on the subject-rated image set; trained on synthetic image pairs… | Deep Opinion-Unaware Blind Image Quality Assessment by Learning and Adapting from Multiple AnnotatorsSource quote0.918 0.859 |
| 6 | MQAF-R | 0.913 | 2026-02-01 | Cross-dataset evaluation: trained on KADID-10K and tested on LIVE, without fine-tunin… | Image Quality Assessment: Exploring Quality Awareness via Memory-driven Distortion Patterns MatchingSource quoteMQAF-R (Ours) │ \bf 0.913 │ \bf0.941 │ \bf 0.903 │ 0.910 │ \bf0.845 │ \bf 0.847 |
| 7 | Life-IQA | 0.8 | 2026-01-01 | Cross-dataset evaluation: trained on KonIQ and tested on LIVE. | Life-IQA: Boosting Blind Image Quality Assessment through GCN-enhanced Layer Interaction and MoE-based Feature DecouplingSource quoteLife-IQA │ \textbf{\textcolor{red}{0.715}} │ \textbf{\textcolor{red}{0.738}} │ \textbf{\textcolor{red}{0.453}} │ \textbf{\textcolor{red}{0.578}} │ 0.822 │ \textbf{\textcolor{red}{0.800}} |
Other primary task on LIVE: Image Quality Assessment · LCC ↑ · test (3 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | WaDIQaM-FR SOTA frontier | 0.98 | 2018-01-01 | evaluation=10 random splits · reference-type=full-reference · patches-per-image=32 · Full LIVE evaluation; 32 patches per image; split by reference image (17 training, 6 … | Deep Neural Networks for No-Reference and Full-Reference Image Quality AssessmentSource quoteWaDIQaM-FR (proposed) │ \bf{0.980} │ 0.970 |
| 2 | MT-RankIQA | 0.976 | 2019-01-01 | distortions=ALL · split_protocol=random 80/20 reference-image train/test split, averaged over 10 runs · Random 80%/20% reference-image train/test split, repeated 10 times and averaged; rank… | Exploiting Unlabeled Data in CNNs by Self-Supervised Learning to Rank.Source quoteMT-RankIQA │ 0.972 │ 0.978 │ 0.988 │ 0.982 │ 0.971 │ 0.976 |
| 3 | NIMA(Inception-v2) SOTA frontier | 0.552 | 2017-09-01 | Trained on AVA and tested on LIVE; cross-dataset evaluation. | NIMA: Neural Image AssessmentSource quoteAVA~\cite{murray2012ava} │ 0.552 │ 0.514 │ 0.636 │ 0.567 |
Other primary task on LIVE: Image Quality Assessment · PCC ↑ (2 papers)
| # | Method | Score ↑ | Year | Protocol / Settings | Paper & Evidence |
|---|---|---|---|---|---|
| 1 | GMSD SOTA frontier | 0.96 | 2013-08-01 | channel=luminance · LIVE database (779 distorted images); evaluated on the luminance channel; PCC compute… | Gradient Magnitude Similarity Deviation: A Highly Efficient Perceptual Image Quality IndexSource quote0.960 |
| 2 | SOS-H-rNSE | 0.946 | 2015-10-01 | distortions=JP2K, JPEG, WN, GB · Common distortion types JP2K, JPEG, WN, and GB; SOS-H-rNSE configuration. | Learn to Evaluate Image Perceptual Quality Blindly from Statistics of Self-similaritySource quoteFrom TABLE~\ref{Table_2}, we can observe that both SOS-MD and SOS-H show good performance on the three databases in terms of PCC and SRC. The best results on all the three databases are achieved by the method SOS-H-rNSE, with PCC values 0.946, 0.933, and 0.937 on the three databases, respectively. For every single distortion type, it also demonstrates PCC and SRC values consistently higher than 0.9. Note that due to the scale difference of subjective scores on the three databases, the resulting RMSE values range differently. |
TaskImage Quality Assessment (93)Medical Note Generation (6)Super Resolution (4)No Reference Image Quality Assessment (2)Image Distortion Classification (2)Blind Image Quality Assessment (2)Speech Recognition (2)
Regimefine-tuned (6)cross-dataset (5)full-reference (2)cross-database (2)source-free-adaptation (1)no-adaptation (1)
Showing 2 of 2 matching observations.
| Year | Method | Metric | Score | Protocol / Facets | Paper & Evidence |
|---|---|---|---|---|---|
| 2019 | MT-RankIQA proposed | LCC | 0.976 | Image Quality Assessment · split: test · fine-tuned · distortions=ALL · split_protocol=random 80/20 reference-image train/test split, averaged over 10 runs | Exploiting Unlabeled Data in CNNs by Self-Supervised Learning to Rank.Source quoteL1264: MT-RankIQA │ 0.972 │ 0.978 │ 0.988 │ 0.982 │ 0.971 │ 0.976 |
| 2016 | WaDIQaM-FR proposed | LCC | 0.980 | Image Quality Assessment · split: test · evaluation=10 random splits · reference-type=full-reference · patches-per-image=32 | Deep Neural Networks for No-Reference and Full-Reference Image Quality AssessmentSource quoteL669: WaDIQaM-FR (proposed) │ \bf{0.980} │ 0.970 |